AMETEK ATC-250

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number ATC-250
Manufacturer AMETEK
Category Temperature Calibrator
Price Request Quote
Lead Time Request Quote

Description

AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, high accuracy,excellent stability, euramet and usb communication.

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need an ATC-250? We can help you find it at a competitive price!

Specifications

Alloy,RTC-158/250 Special aluminium alloy
Frequency, non US deliveries 50 Hz ±5, 60 Hz ±5
Frequency, US deliveries 60 Hz ±5
Humidity 0 to 90% RH
Insert dimensions,RTC-158/250 length 160 mm/6.3 in
Insert dimensions,RTC-158/250 outer diameter 63.5 mm/2.5 in
LAN Ethernet MAC 10/100 Base-T*
Operating ambient temperature 0 to 40°C/32 to 104°F
Output current Maximum 28 mA
Output voltage 24VDC ±10%
Power consumption (max.), RTC-158 400 W
Power consumption (max.), RTC-250 1150 W
Protection class IP-10
SD SD slot* * for future expansion
Serial data interface USB 2.0 device port
USB 2.0 host double port*
Shipping (including optional carrying case),RTC-158 28 kg/61.7 lb
Shipping (including optional carrying case),RTC-250 27 kg/59.6 lb
Shipping (including optional carrying case),Size 50 x 430 x 660 mm/21.7 x 16.9 x 26.0 in
Shipping (without carrying case),RTC-158 17 kg/37.5 lb
Shipping (without carrying case),RTC-250 16 kg/35.3 lb
Shipping (without carrying case),Size 580 x 250 x 500 mm/22.8 x 9.8 x 19.7 in
Storage temperature -20 to 50°C/-4 to 122°F
Switch input (B model only),Switch dry contacts,Test current Maximum 2.5 mA
Switch input (B model only),Switch dry contacts,Test voltage Maximum 5 VDC
Transmitter input mA (B model only), Accuracy (12 months) ±(0.005% Rdg. +0.010% F.S.)
Transmitter input mA (B model only), Range 0 to 24 mA
Voltage 115V (90-127) / 230V (180-254)
Voltage input VDC (B model only),Accuracy (12 months) ±(0.005% Rdg. +0.010% F.S.)
Voltage input VDC (B model only),Range 0 to 12 VDC
Weight and instrument size (L x W x H),RTC-158 11 kg/24.3 lb
Weight and instrument size (L x W x H),RTC-250 9.9 kg/ 21.8 lb

Features

  • DLC: Dynamic Load Compensation Perfect temperature uniformity in the insert, even when calibrating large sensors or many sensors at a time. B and C models only
  • EURAMET:Best performing dry-block with regard to the EURAMET/cg-13/v.01 guideline for testing of dry-blocks
  • Excellent stability 0.01°C
  • Excellent temperature homogeneity: Unique active dual-zone block ensures good temperature homogeneity in the calibration zone
  • High accuracy: Down to ±0.04°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used
  • Intelligent reference sensors: JOFRA reference sensors are supplied with intelligent plugs, holding the calibration data (coefficients) of the reference sensor. This is a truly plug’n’play calibration
  • New sensor basket: In combination with the stirrer the newly developed sensor basket ensures virtually zero axial and radial gradients in the calibration zone
  • Temperature uniformity indicator: Shows the degree of temperature uniformity in the insert when using the new DLC technology. B and C models only
  • USB communication: All RTC calibrators communicate via aneasy-to-use USB port
  • Wide temperature range: RTC-158 from -22 to 155°C (-8 to 311°F) RTC-250 from 28 to 250°C (82 to 482°F)

Datasheet

Download "AMETEK TEST & CALIBRATION INSTRUMENTS-ATC-140-Datashee-899429372t.pdf" (771 KiB)

Extracted Text

NEW! te m p e r at u r e Reference Temperature Calibrator RTC-158 & RTC-250 » High accuracy Down to ±0.04°C using the external refer- ence sensor. 4-wire True-Ohm-Measurement technology is used » Excellent stability 0.01˚C » Wide temperature range RTC-158 from -22 to 155°C (-8 to 311°F) RTC-250 from 28 to 250°C (82 to 482°F) » Excellent temperature homogeneity Unique active dual-zone block ensures good temperature homogeneity in the calibration zone » DLC Liquid Bath Dry-Block Dynamic Load Compensation Perfect temperature uniformity in the insert, even when calibrating large sen- sors or many sensors at a time. B and C models only » Temperature uniformity indicator Shows the degree of temperature uniformity in the insert when using the new DLC technology. AMETEK continues to develop new techniques to improve performance, B and C models only accuracy, convenience and functionality of the well-known JOFRA cali- bration products. By doing so, we maintain our position as the leading » New sensor basket worldwide manufacturer of temperature dry-block calibrators. In combination with the stirrer the newly developed sensor basket ensures virtually zero axial and radial gradients in the Advantages of the combined liquid bath/dry-block calibrator calibration zone Calibration of many sensors at a time due to more space for example in connection with validation of many thermocouples, which saves » Intelligent reference sensors JOFRA reference sensors are supplied with time intelligent plugs, holding the calibration data • Automatic calibration of as many as 24 sensors at a time (coefficients) of the reference sensor. This is a truly plug’n’play calibration system • For customers, who only want to use liquid baths • For calibration of odd sizes and shapes of sensors including » USB communication sanitary sensors All RTC calibrators communicate via an WET = no need for inserts, that fit the sensors easy-to-use USB port DRY = more space for calibration of special sensors • Industries who need to calibrate many sensors at a time or short » EURAMET Best performing dry-block with regard to the sensors can benefit from the big well EURAMET/cg-13/v.01 guideline for testing of • JOFRACAL software and RTC B-models can handle on-line dry-blocks calibration and documentation of multiple sensors calibrated simultaneously ISO 9001 Manufacturer Specification Sheet, SS-RTC-158/250 Both for liquid bath Patent and dry-block use pending! The RTC-158 and RTC-250 Liquid bath versus dry-block kit We are proud to introduce our new top model RTC The basic advantages of the liquid bath configuration ver- (Reference Temperature Calibrator) series, which is even sus the dry-block configuration are as follows: more sophisticated than any existing calibrators. • You do not need insertion tubes for all your different types of sensors The RTC offers many new fantastic features, such as: • You can calibrate sensors, which do not fit into insertion tubes • Patent pending DLC, Dynamic Load Compensation • You can calibrate glass thermometers and gas or liquid system, for perfect temperature uniformity in the insert filled sensors • Unique intelligent sensors for plug’n’play connection • USB connector for communication • You are ready to calibrate right away no matter what • Easy-to-read color VGA display with perfect overview of sensor you may have the actual status • Intuitive, fast and user-friendly navigation • Lightweight and easy to carry around • New functional carrying case design • Multi-hole inserts covering all the most used sensor sizes • High profile design and the well-known long lasting JOFRA quality The new RTC calibrator comes in three different models – A, B, and C. • RTC-A reference temperature calibrator • RTC-B reference temperature calibrator with input for reference sensor, DLC sensor and sensors-under-test • RTC-C reference temperature calibrator with input for reference sensor and DLC sensor The basic advantages of the dry-block configuration versus the liquid bath configuration are as follows: • No hazardous hot liquids • Easier to handle insertion tubes than liquids • More convenient to carry than when filled with liquid • No need for external exhaustion • 100% repeatability in the sensor position in the block All specifications given in the liquid bath configuration are based on the silicone oil supplied and recommended by JOFRA. Liquid bath / large diameter insert The RTC-158/250 are fitted with a 160 mm (6.3 in) deep well with a diameter of 63.5 mm (2.5 in) and can be used both as dry-block calibrators and as liquid calibration baths with a magnetic stirrer. A liquid bath and a dry-block diameter of 63.5 mm (2.5 in), which is twice the size of any other dry-block, are both new features. With these options, it is now possible to calibrate even more temperature sensors simultaneously and to calibrate large as well as odd sizes and shapes of sensors, which is not possible with the remaining product range. RTC-158/250 can be used without an external reference sensor, but if an STS-200 reference sensor is connected directly to a B or C version or the reference thermometer DTI-1000, you will obtain better accuracies and thereby use the full potential of the calibrators. 2 www.jofra.com Reference Temperature Calibrator • RTC-158/250 NEW! plug’n’play These inserts have holes for both the DLC and two reference sensors (4 mm and 1/4”). These holes are marked for correct use. With this multi-hole insert Intelligent reference sensors in the carrying case the The JOFRA STS-200 intelligent reference sensor as well user is able to calibrate as the new DLC sensor are both containing all individual all the most commonly calibration data regarding the sensor. known sensor sizes. Firstly, this means that the time-consuming coefficient downloading sequence with risk of errors is no longer nec- New designed basket essary. Secondly, the user can change the reference sensor The sensor basket is designed to prevent sen- and be up and running immediately. sors from interfering with the stirrer. Numerous tests have been carried out to find the opti- With the intelligent sensors, AMETEK has eliminated a mum design of the sensor basket in regard source of error and the system is now giving a fail-safe to create the largest possible tempe- plug’n’play calibration system. rature homogeneous zone. This work has resulted in a new sensor basket Unique reference sensors performing virtually zero axial and radial gradients in the calibration zone. The new STS-200 reference sensor and the DLC sen- sor have both been special- Intelligent recalibration information ly designed. They are both In order to comply with ISO, SOP’s and FDA it is imperative angled 90˚ and customized to that the calibration equipment never exceeds the expiry of fit the calibrator so they are the calibration certificate. RTC calibrators are constantly only slightly higher than the checking calibration dates on the calibrator as well as for top of the RTC calibrator. the connected STS and DLC sensors. If the calibration period has expired, a warning will appear in the display. The unique design allows cal- This feature prevents costly consequence evaluation. ibration of threaded sensors and sensors with connection Easy-to-read heads without any problems. color display and user-friendly navigation Easy to carry The new 5.7” full color VGA display is very easy to read. The main temperatures, like SET, READ, TRUE and SUT A calibrator is carried from one job to another. Therefore, (Sensor under test) are always displayed at all stages of the it is essential that the weight of the calibrator is as low as programming or calibration procedure. possible. The navigation is menu-driven and very logical to use and We have thoroughly included the weight issue in our design the display shows any important information needed for and have developed new design techniques that have the current function. The communication windows pop up made the RTC calibrator lightweight and easy to carry and are followed by discrete sound messages. The display around without compromising its quality, durability and is very bright and the main information can easily be read functionality. from a distance. The purpose of minimizing the weight of the RTC calibrator is to protect especially frequent users from overload. Improved temperature calibration Time is money! This is why all new RTC calibrators have an increased heating and cooling speed. Heating and cooling speed has been increased by up to 25%. The implication is savings in both production downtime and general calibra- tion costs. Multi-hole inserts With the purpose of covering all sensor sizes, special multi- hole inserts have been developed. The large display contains more detailed information at a Multi-hole inserts come in metric and imperial sizes. glance, such as: Stability status • Load compensation sta- Metric covers all standard sizes from 3 to 12 mm. tus • Real time clock • Serial number of reference sensor • Imperial covers all standard sizes from 1/8 to 1/2 in. Sensor-under-test status RTC-158/250 • Reference Temperature Calibrator www.jofra.com 3 NEW! NEW! Integrated support rod SET-Follows-TRUE (model B & C only) The new integrated support rod is part of the reduced Available on B and C models only, the “SET-Follows-TRUE” weight philosophy. It is lightweight and very easy to mount makes the instrument tune in until the temperature reading on the RTC. Two fixing holes are integrated in the calibrator of the external reference “TRUE” meets the desired “SET” where the support rods can be mounted. The support rod temperature. This feature is important when it is critical that is especially useful in bath calibration. the temperature of the calibration zone matches the desired temperature when measured with accurate external refer- ence sensors. Special designed carrying case AMETEK has designed an all-in-one carrying case. Reading of sensor-under-test (model B only) We have now made it possible to Model B of the RTC is equipped with a built-in accu- store both the STS reference sen- rate measuring circuit for sensor-under-test (input), which sors and the DLC sensor in the car- enables measurement of virtually any type of temperature rying case with an optimum physical sensors including: Resistance thermometers (RTD), ther- protection. There is room for inserts, mocouples (TC), transmitters, milliamps (mA), voltage (V) insulation plugs and calibration oil and thermostats. as well as compartments for the new integrated support rod set, The RTC-B calibrators can be programmed from the key- wires, manuals, certificates, plugs, board for fully automatic sensor calibration. Once the unit is insert tools, etc. programmed, the instrument is self-operating and performs the configured calibration routine. All calibration data are All rooms are specially designed to hold one of the above stored and can be read in the display. mentioned items. This makes it very easy to keep track of any accessories. For optimum protection of the calibrator and the accesso- ries, the compartments are designed to hold the accessories fixed during transportation. The carrying case comes with integrated wheels for easy transportation. MVI - Secure temperature stability MVI stands for ’’Mains power Variance Immunity’’. Switch test (model B only) Unstable mains power is a major contributor to on-site Users may perform a thermoswitch test and find “Open”, calibration inaccuracies. Traditional temperature calibra- “Closed” and the hysteresis (deadband) automatically. The tors often become unstable in production environments instrument retains the last twenty test results. where large electrical motors, heating elements, and other devices are periodically cycled on or off. The cycling of sup- ply power can cause the temperature regulator to perform Auto-stepping inconsistently, leading to both inaccurate readings and Up to 20 different temperature steps may be programmed unstable temperatures. including the hold time for each step. Upon completion of an auto step routine, the user can easily read the results for the sensor-under-test on the RTC display. Results from twenty auto-step calibrations are stored. The “Set temperature” feature allows the user to set the exact desired temperature with a resolution of 0.001°. Highest accuracy (model B & C only) The RTC series calibrators may be supplied with a built-in reference thermometer to be used with an external refer- ence sensor. This feature allows the instrument to perform calibration on-site, while maintaining a high accuracy. The user can decide whether to read the built-in reference Enhanced stability sensor or the more accurate angled reference sensor from A stability indicator shows when the RTC calibrator has the large, easy-to-read LCD display of the calibrator. The reached the desired temperature and is stable. The user external sensor and the internal sensor readings are inde- may change the stability criteria for the external reference pendent of one another. and the sensor-under-test quickly and simply. The stabil- ity criterion is the user’s security of a correct calibration. A count-down timer is displayed next to the temperature read-out. 4 www.jofra.com Reference Temperature Calibrator • RTC-158/250 Work Orders allow the RTC calibrator to: Instrument setups • Operate as a stand-alone instrument using advanced The RTC series allows the user to store up to ten (10) com- calibration routines without the assistance of a personal plete instrument setups. You may store all sorts of informa- computer on site. The work order functionality tion including temperature units, stability criteria, use of • Prevent unauthorized changes to a calibration routine. external reference sensors, resolutions, sensors-under-test Personnel who are not authorized to alter a calibration (SUT), conversions to temperature, display contrasts, etc. routine cannot do so The setup may be recalled at any time. Once all calibrations are completed, the data may be up- Maximum and minimum temperature loaded to the JOFRACAL for printing of certificates. The From the setup menu, the user can select the maximum data collected can of course be stored on the personal and minimum temperature limit for the calibrator. This func- computer for later recall or analysis. tion prevents damage to the sensor-under-test caused by excessive temperatures and it helps reducing sensor drift JOFRACAL offers extended output formats of the cap- from exposures of too high temperatures. This feature can tured calibration data such as PDF file format and ASCII/ be locked with an access code. semicolon separated text format for further processing and calculation of data in spreadsheets and word processors. Silent operation As found/As left (model B only) The RTC calibrator can be programmed to run in silent operation. This function is an advantage if calibrating in a When running a calibration initiated from a work order, the laboratory or in an office. During silent operation, the cali- user can select the calibration as an As Found or an As Left brator is not using its full speed potential. calibration. SYNC output Calibration of indication devices A synchronization output signals when the instrument is When calibrating an indicating device in the work order stable and may be used with ancillary devices such as mode, users may key in the results during or after the test. video recorders, digital cameras or as an input to a data Using the “Calibration info” function, the user may view the logging device. The SYNC output may be useful for au- complete calibration task, including the “Scenario” before tomating and documenting calibration when calibrating the calibration takes place. external reading devices. Calibration of up to 24 sensors JOFRACAL calibration software with JOFRA ASM JOFRACAL is a highly versatile calibration software sup- Using the RTC series together with the ASM, Advanced plied with the RTC calibrators. The software ensures easy Signal Multi-scanner, offers a great time-saving automatic calibration of all kind of temperature sensors, such as solution to calibrate multiple temperature sensors at the RTD´s, thermocouples, transmitters and thermoswithes. same time. The ASM series is an eight channel scanner Furthermore, it can be used for pressure calibration i.e. controlled by the JOFRACAL software on a PC. Up to 3 pressure gauges and pressure switches. ASM units can be stacked to calibrate up to 24 sensors at a time. It can handle signals from 2-, 3- and 4-wire RTD’s, thermocouples, transmitters, temperature switches and voltage. JOFRACAL integrates with JOFRA calibration instruments. Hardware requirements As for temperature calibrators, it is the whole range of 1.1.1 PCs, minimum hardware requirements: temperature calibrators. Regarding pressure calibrators, it ® ® • Intel Pentium lI 1.4 GHz processor integrates with DPC-500, HPC and IPI pressure calibrators. • 128MB RAM (256MB recommended) JOFRACAL also has full integration with the series of signal • 512MB free disk space on hard disk (1GB recommended) calibrators. prior to installation • Standard VGA (800x600, 256 colors). 1024x768 recom- JOFRACAL can also be used for manual calibrations, as it can mended be set up to accept manual entry of calibration data together • USB port with other liquid baths, ice points or dry-block heat sources. • One or more free RS-232 serial and USB ports, if using de- vices requiring RS-232 communication The collected calibration data can be stored on a PC for later recall or analysis. The RTC calibrator can be pro- 1.1.2 PCs, minimum software requirements: grammed to store the calibration procedures and may be ® ® • Microsoft Windows ME, Microsoft Windows XP, Window 7 taken out to the process site without bringing a personal • System fonts: MS Sans Serif and Arial computer. This feature is named Work Orders. RTC-158/250 • Reference Temperature Calibrator www.jofra.com 5 Free download www.jofra.com Based on the new DLC functionality, the RTC is the best Unique temperature performance performing dry-block calibrator on the market, when being The RTC series of calibrators provides precision tempera- calibrated and tested according to the globally accepted ture calibration of sensors, whatever the type or format. EURAMET/cg-13/v.01 guideline for calibration and testing This is accomplished through an innovative active dual- of dry-blocks. zone heating technology. The DLC system comprises a special differential temperature The RTC-series features our well-known active dual-zone sensor designed especially for the RTC. The sensor is placed heating technology. Each heating zone is independently in the insert and connected to the calibrator. When the DLC controlled for precision temperature calibration. The homo- function is enabled, the calibrator will automatically equalize geneity in the lower part is close to that of a laboratory the temperature homogeneity inside the insert on top of the liquid bath. The lower zone ensures optimum heat dissipa- normal temperature control and stabilization. tion throughout the entire calibration zone. The upper zone compensates for heat loss from the sensor-under-test and DLC - User advantages from the open top. This design also eliminates the need for Calibrating with DLC sensor has the following advantages: extra insulation of sensors-under-test and makes it possible 1. Calibration of several sensors simultaneously to calibrate liquid-filled and other mechanical sensors. 2. Calibration of thick sensors 3. TSL (Thermo Sensitive Length) independency. It is no longer necessary to know the TSL of the sensor 4. Compensation for sensor production tolerances like the PT100 element being mounted in various positions in the sensor 5. Trouble-free calibration of sensors with PT100 elements up to a 60 mm length 6. Verification that the dual-zone is active and well-functioning 7. A perfectly working calibrator. The DLC value should be very close to 0.00 when the calibrator is loaded with a DLC sensor and an external reference sensor 8. Together with the stability indication, the DLC indicates DLC - Dynamic Load Compensation when the calibration values can be read To bring our well documented active dual-zone tech- nology to an even higher level, we have developed the patent pending new DLC system. This newly developed unique feature makes it possible to perform top calibration specifications without being affected by the actual load e.g. many sensors or very big sensors. A new DLC sensor, Dynamic Load Compensation sensor, has been specially developed for this purpose. The RTC calibrator features the active dual zone tempera- ture control which improves the homogeneity in the well by adjusting the temperature in the top of the well to the same temperature as in the bottom. The dual zone keeps this dif- ference at a minimum. DLC Sensor The new DLC sensor Axial temperature curves for an RTC calibrator with and improves the homogene- without the DLC functionality activated. DLC controlling is ity even more by controlling automatically disabled when the stirrer is started. the homogeneity not only in the well, but also inside the USB connector for communication insert, where the sensors- Another new RTC feature is the USB connection that facili- under-test are placed during tates easy communication with JOFRACAL. The USB con- calibration. The DLC sensor nection also supports easy download of future firmware measures the temperature upgrades. homogeneity in the insert and provides feedback to The USB connection provides fast and easy access to all the active dual-zone system, laptops without the need of RS-232 to USB converters. which now compensates the temperature difference to a Future-proof through e.g. a flash capability for easy firm- minimum inside the insert. ware upgrades as well as already integrated LAN commu- In this way, the DLC func- nication, SD-card slot and USB host connectors for future tion makes the homogeneity use. independent of the different loads of the insert. 6 www.jofra.com Reference Temperature Calibrator • RTC-158/250 Patent pending! NEW! INSERTS AND LIQUID BATH KIT Undrilled inserts for RTC-158/250 1/4 in Inserts, undrilled Reference RTC-158 RTC-250 1 Insert Code Insert sensor (UN3) A/B/C A/B/C UN1 Undrilled insert 124899 127758 4 mm Undrilled insert UN2 127829 127834 Reference with DLC sensor (UN3) Undrilled insert with DLC UN3 and reference sensor 4 127831 127835 mm and 1/4 in Note 1: Use the insert code when ordered as the DLC standard insert together with a new calibrator. (UN2 & UN3) 12 mm 4 mm 8 mm 3 mm Metric (mm) 6 mm Multi-hole inserts for RTC-158/250 Spare part no. for multi-hole inserts - metric (mm) 4 mm 1/4 in Instruments Reference Reference 1 Insert code RTC-158 A/B/C RTC-250 A/B/C sensor sensor M01 124897 127759 Note 1: Use the insert code when ordered as the standard insert together with a new calibrator. 5 mm 9 mm 6 mm 11 mm DLC 1/2 in 3/16 in 1/8 in 5/16 in Imperial (Inch) 1/4 in Multi-hole inserts for RTC-158/250 Spare part no. for multi-hole inserts - imperial (inch) 1/4 in Instruments Reference 1 Insert code RTC-158 A/B/C RTC-250 A/B/C 4 mm sensor Reference M02 124898 127760 sensor Note 1: Use the insert code when ordered as the standard insert together with a new calibrator. 3/16 in 3/8 in 1/4 in All inserts are supplied with a matching insulation 7/16 in DLC plug. Liquid Bath Kit - Option BAT The liquid bath kit for RTC-158/250 contains a sensor basket, 2 covering lids, a magnet, a magnetic remover, a liquid drainage tube and 0.75 l silicone oil. RTC-158/250 • Reference Temperature Calibrator www.jofra.com 7 FUNCTIONAL SPECIFICATIONS INPUT SPECIFICATIONS All input specifications apply to the dry-block of the calibrator Temperature range running at the respective temperature (stable plus an additional RTC-158 20 minute period). @ ambient temp. 0°C/32°F ........-37 to 155°C/-51 to 311°F All input specifications are valid for RTC-158 and RTC-250. @ ambient temp. 23°C/73°F ......-22 to 155°C/-22 to 311°F @ ambient temp. 40°C/104°F ......-9 to 155°C/ 5 to 311°F RTC-250 RTD reference input (B & C models only) @ ambient temp. 0°C/32°F .............5 to 250°C/41 to 482°F 1) Type .................. 4-wire RTD with true ohm measurements @ ambient temp. 23°C/73°F .........28 to 250°C/82 to 482°F F.S. (Full Scale) ......................................................400 ohm @ ambient temp. 40°C/104°F .....45 to 250°C/113 to 482°F Accuracy (12 months) ...... ±(0.0012% rdg. + 0.0005% F.S.) RTD Type Temperature 12 months Accuracy (model B & C) with external STS ref. sensor °C °F °C °F RTC-158 B & C ......................................... ±0.04°C/±0.07°F -22 -8 ±0.008 ±0.015 Pt100 RTC-250 B & C ......................................... ±0.07°C/±0.13°F 0 32 ±0.008 ±0.015 reference 12-month period. Relative to reference standard. Specs by use of 28 82 ±0.009 ±0.016 the external STS-200 reference sensor. Excl. sensor drift. 155 311 ±0.011 ±0.020 250 482 ±0.012 ±0.022 Accuracy with internal reference sensor Note 1: True ohm measurement is an effective method to RTC-158 A, B & C ..................................... ±0.18°C/±0.32°F eliminate errors from induced thermoelectrical voltage RTC-250 A, B & C ..................................... ±0.28°C/±0.50°F DLC sensor input (B & C models only) Stability Type Temperature 12 months RTC-158 .................................................. ±0.01°C/±0.018°F °C °F °C °F RTC-250 .................................................. ±0.02°C/±0.036°F -22 -58 ±0.014 ±0.025 DLC 155 Measured after the stability indicator has been on for 15 minutes. 0 32 ±0.010 ±0.018 Measuring time is 30 minutes. 28 82 ±0.010 ±0.018 155 311 ±0.008 ±0.015 Radial homogeneity (difference between holes) 250 482 ±0.008 ±0.015 RTC-158 @ -22°C/-8°F, Block .......................0.03°C/0.05°F * at 0.00°C / 0.00°F DLC reading RTC-158 @ 155°C/311°F, Block ....................0.05°C/0.09°F RTD sensor under test input (B model only) RTC-158 @ range, Bath ...............................0.015°C/0.03°F RTC-250 @ range, Block ................................0.05°C/0.09°F F.S. (range) .............................................................400 ohm RTC-250 @ range, Bath ...............................0.015°C/0.03°F Accuracy (12 months).................. ±(0.002% Rdg.+0.002% F.S.) F.S. (range) ...........................................................4000 ohm Accuracy (12 months) ........ ±(0.005% Rdg. + 0.005% F.S.) Resolution (user-selectable) 2-wire ............................................................add 50 mOhm All temperatures ......................1° or 0.1° or 0.01° or 0.001˚ RTD Type Temperature 12 months °C °F °C °F Heating time -22 -8 ±0.025 ±0.045 Pt100 RTC-158 -22 to 23°C/-8 to 73°F ................... 9 minutes 0 32 ±0.026 ±0.047 90(385) 23 to 100°C/73 to 212°F .............. 23 minutes 28 82 ±0.026 ±0.047 IEC 100 to 155°C/212 to 311°F .......... 28 minutes 155 311 ±0.030 ±0.054 RTC-250 28 to 100°C/82 to 212°F ................ 3 minutes 250 482 ±0.033 ±0.060 50 to 100°C/122 to 212°F .............. 2 minutes -22 -8 ±0.113 ±0.203 Pt500 100 to 250°C/212 to 482°F ............ 9 minutes 0 32 ±0.116 ±0.209 90(385) 28 82 ±0.118 ±0.212 IEC 155 311 ±0.129 ±0.232 Cooling time 250 482 ±0.131 ±0.236 RTC-158 155 to 100°C/311 to 212°F ............ 9 minutes -22 -8 ±0.063 ±0.114 Pt1000 100 to 23°C/212 to 73°F .............. 24 minutes 0 32 ±0.064 ±0.115 90(385) 23 to 0°C/73 to 32°F .................... 15 minutes 28 82 ±0.066 ±0.119 IEC 0 to -15°C/32 to 5°F .................... 21 minutes 155 311 ±0.075 ±0.135 RTC-250 250 to 100°C/482 to 212°F .......... 27 minutes 250 482 ±0.082 ±0.148 100 to 50°C/212 to 122°F ............ 27 minutes Input and curves for many different resistance sensors 50 to 28°C/122 to 82°F ................ 28 minutes such as: Time to stability (approx.) 0-400Ω RTC-158 ............................................................. 15 minutes (P10(90)386/P50(90)385/P100(90)385/P50(90)391/ RTC-250 ............................................................. 15 minutes P100(90)391/P100(90)392/M50(90)428/M100(90)428/ H120(90)672/Pt-100 MILL) Immersion depth 0-4000Ω RTC-158/250 incl. insulation plug ................ 180 mm/7.1 in (P200(90)385/P500(90)385/P1000(90)385/YSI-400) RTC-158/250 bath version ........................... 150 mm/5.9 in 8 www.jofra.com Reference Temperature Calibrator • RTC-158/250 Thermocouple input Mains specifications Range ..................................................................... ±78 mV Voltage ...............................115V (90-127) / 230V (180-254) F.S. (Full Scale) ......................................................... 78 mV Frequency, non US deliveries ...............50 Hz ±5, 60 Hz ±5 Accuracy (12 months) ........ ±(0.005% Rdg. + 0.005% F.S.) Frequency, US deliveries .......................................60 Hz ±5 Power consumption (max.), RTC-158 ........................400 W TC Type Temperature 12 months* Power consumption (max.), RTC-250 ......................1150 W °C °F °C °F -50 -58 ±0.09 ±0.17 E 0 32 ±0.06 ±0.11 Communication interface 155 311 ±0.06 ±0.11 Serial data interface .............................USB 2.0 device port 320 608 ±0.07 ±0.13 Serial data interface ...................USB 2.0 host double port* -50 -58 ±0.10 ±0.18 J . LAN ...................................... Ethernet MAC 10/100 Base-T* 0 32 ±0.08 ±0.14 SD ............................................................................ SD slot* 155 311 ±0.09 ±0.16 * for future expansion 320 608 ±0.09 ±0.16 -50 -58 ±0.14 ±0.24 K 0 32 ±0.10 ±0.19 Miscellaneous 155 311 ±0.11 ±0.20 Operating ambient temperature ........0 to 40°C/32 to 104°F 320 608 ±0.11 ±0.20 Storage temperature ....................... -20 to 50˚C/-4 to 122˚F -50 -58 ±0.15 ±0.26 T Humidity ......................................................... 0 to 90% RH 0 32 ±0.10 ±0.18 Protection class ..........................................................IP-10 155 311 ±0.08 ±0.15 320 608 ±0.08 ±0.15 -50 -58 ±1.30 ±2.35 PHYSICAL SPECIFICATIONS R 0 32 ±0.78 ±1.40 155 311 ±0.47 ±0.84 Weight and instrument size (L x W x H) 320 608 ±0.40 ±0.72 RTC-158 ..........................................................11 kg/24.3 lb -50 -58 ±0.98 ±1.76 S RTC-250 ........................................................9.9 kg/ 21.8 lb 0 32 ±0.78 ±1.40 RTC-158/250 .... 366 x 171 x 363 mm / 14.4 x 6.7 x 14.3 in 155 311 ±0.49 ±0.89 320 608 ±0.45 ±0.81 -50 -58 ±0.20 ±0.35 N Shipping (without carrying case) 0 32 ±0.15 ±0.27 RTC-158 ..........................................................17 kg/37.5 lb 155 311 ±0.13 ±0.23 RTC-250 ..........................................................16 kg/35.3 lb 320 608 ±0.13 ±0.24 Size ......................580 x 250 x 500 mm/22.8 x 9.8 x 19.7 in -50 -58 ±0.13 ±0.24 U 0 32 ±0.10 ±0.18 155 311 ±0.08 ±0.14 Shipping (including optional carrying case) 320 608 ±0.08 ±0.15 RTC-158 ..........................................................28 kg/61.7 lb * Excl. CJC accuracy ±0.3˚C / ±0.54˚F RTC-250 ..........................................................27 kg/59.6 lb Size ....................550 x 430 x 660 mm/21.7 x 16.9 x 26.0 in Transmitter supply Output voltage ................................................24VDC ±10% Output current .......................................... Maximum 28 mA INSERTS Insert dimensions Transmitter input mA (B model only) RTC-158/250 outer diameter .......................63.5 mm/2.5 in Range ................................................................. 0 to 24 mA RTC-158/250 length ......................................160 mm/6.3 in Accuracy (12 months) ..........±(0.005% Rdg. +0.010% F.S.) Weight of non-drilled insert (approx.) Voltage input VDC (B model only) RTC-158/250 ................................................1200 g/42.3 oz Range: .............................................................. 0 to 12 VDC Accuracy (12 months) ..........±(0.005% Rdg. +0.010% F.S.) Alloy RTC-158/250 .................................. Special aluminium alloy Switch input (B model only) Switch dry contacts Test voltage ...............................................Maximum 5 VDC Test current ..............................................Maximum 2.5 mA RTC-158/250 • Reference Temperature Calibrator www.jofra.com 9 NEW! STANDARD DELIVERY ACCESSORIES Model A, B and C: Carrying Case - Option CT • RTC dry-block calibrator (user specified) With our new special designed • Mains power cable (user specified) carrying case it is now possible to • Traceable certificate - temperature performance store all your sensors in the case • Tool for insertion tubes with an optimum physical protec- • JOFRACAL tion. An improved integrated trolley • AMETRIM system for easy and safe transpor- • USB cable tation. • Set of rubber cones for insulation plugs • Manuals Model B contains the following extra items: • Test cables (2 x red, 2 x black) Support rod set - Option SR • Traceable certificate - input performance for reference Support rod for sensors to be sensor and DLC sensor mounted on all JOFRA RTC dry- • Traceable certificate - input performance for sensor- block calibrators. Holds the sensor under-test inputs under test in the right position, while calibrating. Includes 2 sensor grips Model C contains the following extra items: and 2 fixtures for sensor gribs. • Traceable certificate - input performance for reference sensor and DLC sensor EXTRA PARTS 127277 Support rod set for sensors, 2 gribs, 2 fixtures 125066 Extra fixture for sensor grib 125067 Extra sensor grib 122771 Mini-Jack connector for stable relay output 120516 Thermocouple Male Plug - Type J - Black 120517 Thermocouple Male Plug - Type K - Yellow 120514 Thermocouple Male Plug - Type N - Orange 120515 Thermocouple Male Plug - Type T - Blue 120518 Thermocouple Male Plug - Type R / S - Green 120519 Thermocouple Male Plug - Type Cu-Cu - White 125033 Silicone oil, Type 200/10cSt, 0.75 L, RTC-158 124885 Silicone oil, Type 200/50cSt, 0.75 L, RTC-250 125022 Liquid Bath Kit, RTC-158 Model A Model C Model B 125035 Liquid Bath Kit, RTC-250 127782 Carrying case with Trolley FUNCTIONAL COMPARISON Model A Model B Model C Dual-zone heating/cooling block • • • MVI - Mains Variance Immunity (or similar) • • • Stability indicator • • • Automatic step function • • • USB communication • • • Display resolution 0.001˚ • • • Programmable max. temperature • • • SYNC output (for external recording device) • • • Calibration of short sensors in special insert • • External precision reference sensor input • • External precision DLC reference sensor input • • “SET” follows “TRUE” • • Load compensation functionality • • Input for RTD, TC, V, mA • 4-20 mA transmitter input incl. 24 VDC supply • All inputs scalable to temperature • Automatic switch test (open, close and hysteresis) • Download of calibration work orders from PC • Upload of calibration results (as found & as left) • 10 www.jofra.com Reference Temperature Calibrator • RTC-158/250 ORDERING INFORMATION Order number Description Base model number RTC158 RTC-158 Series, -22 to 155˚C (-8 to 311˚F) RTC250 RTC-250 Series, 28 to 250˚C (82 to 482˚F) Model version A Basic model, without input B Full model, incl. DLC sensor input, Reference sensor input, Sensor-under-test input C Middle model, incl. DLC sensor input, Reference sensor input Power supply (US deliveries 60 Hz only) 115 115VAC 230 230VAC Mains power cable A European, 230V B USA/Canada, 115V C UK, 240V D South Africa, 220V E Italy, 220V F Australia, 240V G Denmark, 230V H Switzerland, 220V I Israel, 230V Insert type and size NON No insert selected (standard) UNX 1 x Undrilled Insert (Please see Insert selection for code) MXX 1 x Multi hole insert (Please see Insert selection for code) BAT Liquid bath kit Dynamic Load Compensation (B & C models only, optional) DLC DLC sensor STS Reference sensor (B & C models only, optional) R1 STS-102 Ref. sensor. Dia. 4mm. Length 30mm (STS102A030EH) For RTC-158 R6 STS-200 Ref. sensor. Dia. 4mm. Length 183mm (STS200A916) For RTC-158 R7 STS-200 Ref. sensor. Dia. 1/4”. Length 183mm (STS200B916) For RTC-158 R8 STS-200 Ref. sensor. Dia. 4mm. Length 183mm (STS200A925) For RTC-250 R9 STS-200 Ref. sensor. Dia. 1/4”. Length 183mm (STS200B925) For RTC-250 Calibration Certificate F Traceable Callibration Certificate (standard) H Accredited Calibration Certificate EA Full EURAMET Calibration Certificate FS Traceable System Calibration Certificate (B & C models only) HS Accredited System Calibration Certificate (B & C models only) EAS Full EURAMET System Calibration Certificate (B & C models only) EASD Full EURAMET System Calibration Certificate with DLC (B & C models only) Accessories CT Solid Protective Carrying case with integrated trolley SR Support rod set TR Solid Protective Carrying case with integrated trolley & Support rod set Sample order number JOFRA RTC-158 B with 230VAC, EU power cord, set of metric inserts, DLC, STS-200 ref. sensor, full EA temp. RTC158 B 230 A SM DLC R2 EA CT calibration certificate, and carrying case with integrated trolley. RTC-158/250 • Reference Temperature Calibrator www.jofra.com 11 AMETEK Test & Calibration Instruments A business unit of AMETEK Measurement & Calibration Technologies Division offering the following industry leading brands for test and calibration instrumentation. JOFRA Calibration Instruments Temperature Calibrators Portable dry-block calibrators, precision thermometers and liquid baths. Temperature ranges from -90°C(-130°F) to 1205°C(2200°F). Temperature sensors for industrial and marine use. Pressure Calibrators Convenient electronic systems ranging from -25 mbar to 1000 bar - fully temperature-compensated for problem- free and accurate field use. Signal Instruments Process signal measurement and simulation for easy control loop calibration and measurement tasks. M&G Pressure Testers & Pumps Pneumatic floating-ball or hydraulic piston dead weight testers with accuracies to 0.015% of reading. Pressure generators delivering up to 1,000 bar. Lloyd Instruments Materials testing machines and software from Lloyd Instruments guarantees expert materials testing solutions. The comprehensive program also covers Texture Analysers to perform rapid, general food testing and detailed texture analysis on a diverse range of foods and cosmetics. Davenport Polymer Test Equipment Allows measurement and characterization of moisture- sensitive PET polymers and polymer density. Chatillon Force Measurement The hand held force gauges and motorized testers have earned their reputation for quality, reliability and accuracy and they represent the de facto standard for force measurement. Newage Testing Instruments Hardness testers, durometers, optical systems and software for data acquisition and analysis. www.jofra.com AMETEK Mansfield & Green (North America) T: +1 800 527 9999 | cal.info@ametek.com AMETEK Singapore Pte. Ltd. (Singapore) T: +65 6 484 2388 | aspl@ametek.com.sg AMETEK Inc. Beijing Rep. Office (China) AMETEK Denmark A/S T: +86 10 8526 2111 | jofra@ametek.com.cn Gydevang 32-34 | 3450 Allerød | Denmark AMETEK Instruments India Pvt Ltd. (India) T: +45 4816 8000 | ametek@ametek.dk T: +91 22 2836 4750 | ametek@ametek.dk AMETEK GmbH (Germany) T: +49 2159 9136 510 | info.mct-de@ametek.de AMETEK Calibration Instruments (UK) Information in this document is subject to change without notice. ©2011, by AMETEK, Inc., www.ametek.com. All rights reserved. T: +44 (0) 1243 833 302 | jofra@ametek.co.uk 12 www.jofra.com Pub code SS-RTC-158/250 Issue 1111

Related Products

AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 120516, Temperature calibrator Thermo...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 120517, Temperature calibrator Thermo...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 125002, Temperature calibrator, Edge...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 125068, Temperature calibrator, Suppo...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 60F174, Temperature calibrator, Clean...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator,Reference Tem...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.04 seconds.