Details

Part Number ATC-156
Manufacturer AMETEK
Category Temperature Calibrator
Price Request Quote
Lead Time Request Quote

Description

AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, Intelligent reference sensors, Display indicator
for temperature uniformity and USB communication.

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need an ATC-156? We can help you find it at a competitive price!

Specifications

Frequency, non US deliveries 50 Hz ±5, 60 Hz ±5
Frequency, US deliveries 60 Hz ±5
Output current Maximum 28 mA
Output voltage 24VDC ±10%
Power consumption (max.) 400 W
RTC-156 @ ambient temp. 0°C/32°F -46 to 155°C/-51 to 311°F
RTC-156 @ ambient temp. 23°C/73°F -30 to 155°C/-22 to 311°F
RTC-156 @ ambient temp. 40°C/104°F -15 to 155°C/ 5 to 311°F
RTC-156/157 290 g/10.2 oz
RTC-156/157 inner diameter (multi hole) 25.6 mm/1.01 in
RTC-156/157 length 150 mm/5.91 in
RTC-156/157 outer diameter 29.7 mm/1.17 in
RTC-157 @ ambient temp. 0°C/32°F -57 to 155°C/-71 to 311°F
RTC-157 @ ambient temp. 23°C/73°F -45 to 155°C/-49 to 311°F
RTC-157 @ ambient temp. 40°C/104°F -31 to 155°C/-24 to 311°F
Test current Maximum 2.5 mA
Test voltage Maximum 5 VDC
Voltage 115V (90-127) / 230V (180-254)
Weight and instrument size (L x W x H) RTC-156/157 10.5 kg/23.2 lb
362 x 171 x 363 mm/14.3 x 6.7 x 14.3 in

Features

  • Easy-to-read color VGA display with perfect overview of the actual status
  • High profile design and the well-known long lasting JOFRA quality
  • Intuitive, fast and user-friendly navigation
  • Lightweight and easy to carry around
  • New functional carrying case design
  • New multi-hole insert kits covering all the most used sensor sizes
  • Patent pending DLC, Dynamic Load Compensation system, for perfect temperature uniformity in the insert
  • Unique intelligent sensors for plug’n’play connection
  • USB connector for communication

Datasheet

Download "AMETEK TEST & CALIBRATION INSTRUMENTS-ATC-156-Datashee-1711961393t.pdf" (615 KiB)

Extracted Text

Best dry-blocks on the market! Patent pending! te m p e r at u r e Reference Temperature Calibrator Model RTC-156 & RTC-157 » High accuracy Down to ±0.04°C using the external refer- ence sensor. 4-wire True-Ohm-Measurement technology is used. » Excellent stability 0.005˚C » Wide temperature range RTC-156 from -30 to 155°C (-22 to 311°F) RTC-157 from -45 to 155°C (-49 to 311°F) » Improved temperature homogeneity Unique active dual-zone block ensures good temperature homogeneity in the calibration zone » DLC Dynamic Load Compensation Perfect temperature uniformity in the insert, even when calibrating large sen- sors or many sensors at a time. B and C models only DLC » Display indicator AMETEK continues to develop new techniques to improve performance, for temperature uniformity accuracy, convenience and functionality of the well-known JOFRA cali- Shows the degree of temperature uniformity in bration products. By doing so, we maintain our position as the leading the insert when using the new DLC technology. worldwide manufacturers of temperature dry-block calibrators. B and C models only We are proud to introduce our new top model RTC (Reference Temperature Calibrator), which is no exception to the above and even more sophisti- » Intelligent reference sensors cated than any existing calibrators. JOFRA reference sensors are supplied with intelligent plugs, holding the calibration data The RTC offers many new fantastic features, such as: (coefficients) of the reference sensor. This is • Patent pending DLC, Dynamic Load Compensation system, for perfect a truly plug’n’play calibration system temperature uniformity in the insert • Unique intelligent sensors for plug’n’play connection » USB communication • USB connector for communication All RTC calibrators communicate via an • Easy-to-read color VGA display with perfect overview of the actual status easy-to-use USB port • Intuitive, fast and user-friendly navigation • Lightweight and easy to carry around • New functional carrying case design » EURAMET • New multi-hole insert kits covering all the most used sensor sizes Best performing dry-block with regard to the • High profile design and the well-known long lasting JOFRA quality EURAMET/cg-13/v.01 guideline for testing of dry blocks The new RTC calibrator comes in three different models – A, B, and C. • RTC-A reference temperature calibrator • RTC-B reference temperature calibrator with input for reference sensor, DLC sensor and sensors-under-test • RTC-C reference temperature calibrator with input for reference sensor ISO 9001 Manufacturer and DLC sensor Specification Sheet, SS-RTC-156/157 tionality, the RTC is the best performing dry-block calibrator Unique temperature performance on the market, when being calibrated and tested according The RTC series of calibrators provides precision tempera- to the globally accepted EURAMET/cg-13/v.01 guideline for ture calibration of sensors, whatever the type or format. calibration and testing of dry-blocks. This is accomplished through an innovative active dual- zone heating technology. The DLC system comprises a special differential temperature sensor designed especially for the RTC. The sensor is placed The JOFRA RTC-series features our well-known active dual- in the insert and connected to the calibrator. When the DLC zone heating technology. Each heating zone is indepen- function is enabled, the calibrator will automatically equalize dently controlled for precision temperature calibration. The the temperature homogeneity inside the insert on top of the homogeneity in the lower part is close to that of a laboratory normal temperature control and stabilization. liquid bath. The lower zone ensures optimum heat dissipa- tion throughout the entire calibration zone. The upper zone DLC - User advantages compensates for heat loss from the sensor-under-test and Calibrating with DLC sensor gives the following advantages: from the open top. This design also eliminates the need for 1. Calibration of several sensors simultaneously extra insulation of sensors-under-test and makes it possible 2. Calibration of thick sensors to calibrate liquid-filled and other mechanical sensors. 3. Gives TSL (Thermo Sensitive Length) independency. It is no longer necessary to know the TLS of the sensor 4. Compensates for sensor production tolerances like the PT100 element being mounted in various positions in the sensor 5. Trouble free calibration of sensors with PT100 elements up to 60 mm length 6. The DLC indicator proves that the dual-zone is active an functioning well 7. Proves that the calibrator is working perfect. The DLC value should be very close to 0.00 when the calibrator is loaded with DLC sensor and an external reference sensor DLC - Dynamic Load Compensation 8. Together with the stability indication, the CLD indicates when the calibration values can be read To bring our well documented active dual- zone technology to an even higher level, we have developed the patent pending new DLC system. This newly developed unique feature makes it possible to perform top calibration specifications without being affect- ed by the actual load e.g. many sensors or very big sensors. A new DLC sensor, Dynamic Load Compensation sensor, has been specially developed for this purpose. The RTC calibrator features the active dual zone tempera- ture control which improves the homogeneity in the well by adjusting the temperature in the top of the well to the same temperature as in the bottom. The dual zone keeps this dif- ference at a minimum. DLC Sensor The new DLC sensor Axial temperature curves for a RTC calibrator with and with- improves the homogene- out the DLC functionality activated ity even more by controlling the homogeneity not only in the well, but also inside the USB connector for communication insert, where the sensors- Another new RTC feature is the USB connection that facili- under-test are placed during tates easy communication with JOFRACAL. The USB con- calibration. The DLC sensor nection also supports easy download of future firmware measures the temperature upgrades. homogeneity in the insert and provides feedback to The new USB connection provides fast and easy access to the active dual-zone system, all laptops without the need of RS-232 to USB converters. which now compensates the temperature difference to a Future-proof through e.g. a flash capability for easy firm- minimum inside the insert. ware upgrades as well as already integrated LAN commu- In this way, the DLC func- nication, SD-card slot and USB host connectors for future tion makes the homogeneity use. independent of the different loads of the insert. Based on the new DLC func- 2 www.jofra.com Reference Temperature Calibrator • RTC-156/157 Patent pending! NEW! NEW! plug’n’play -24˚C @15 min. New multi-hole insert kits Two special multi-hole insert kits have been developed to comply with calibration of almost any sensor diameter with- out having to buy numerous inserts. The first kit is a metric insert kit consisting of only four inserts covering all diameters from 3 to 13mm. The other is Intelligent reference sensors an imperial insert kit consisting of only three inserts cover- The JOFRA STS-200 intelligent reference sensors as well ing six different sizes from ⅛” to ½”. as the new DLC sensor are all containing all individual cali- bration data regarding the sensor. All inserts have holes for both STS reference sen- Firstly, this means that the time-consuming coefficient sors and DLC sensors. downloading sequence with risk of errors is no longer nec- essary. Secondly, the user can change the reference sensor With this new insert kit and be up and running immediately. in the carrying case, the user is now able to With the intelligent sensors, AMETEK has eliminated a calibrate all commonly source of error and the system is now giving a fail-safe known sensor sizes. plug’n’play calibration system. These new insert kits are Unique part of the JOFRA light- weight strategy. reference sensors The new STS-200 refer- Wide temperature range ence sensors and the DLC The RTC-series can perform calibration over a very wide sensors have been spe- temperature range starting from -45°C and up to 155°C cially designed. They are (-49 to 311°F). This makes it possible to perform calibration both angled 90˚ and have jobs over a range of 200°C (360°F) with only one calibrator. been customized to fit the calibrator so they are only slightly higher than the top Easy-to-read of the RTC calibrator. color display and user-friendly navigation The new 5.7” full color VGA display is very easy to read. The unique design makes The main temperatures, like SET, READ, TRUE and SUT it possible to calibrate (Sensor under test), are always displayed at all stages of the threaded sensors and sen- programming or calibration procedure. sors with connection heads without any problems. Easy to carry A calibrator is carried from one job to another. Therefore, it is essential that the weight of the calibrator is as low as possible. We have thoroughly included the weight issue in our design and have developed new design techniques that have made the RTC calibrator lightweight and easy to carry around without compromising its quality, durability and functionality. The navigation is menu-driven and very logical to use and the display shows any important information needed for the The purpose of minimizing the weight of the RTC calibrator current function in use. The communication windows pop is to protect, especially frequent users from overload. up and are followed by discrete sound messages. The display is very bright and the main information can eas- Same size of inserts ily be read from a distance. The new cooling calibrator RTC-156/157 are using the same insert dimensions (30x150mm) as some of our exist- The large display contains more detailed information at a ing calibrators. This makes it possible to reuse inserts from glance, such as: other calibrators. • Stability status Fast temperature calibration • Load compensation status Time is money! This is why all the new RTC calibrators • Real time clock have an increased heating and cooling speed compared to • Serial number of reference sensor • Sensor-under-test status all other calibrators. Heating and cooling speed has been increased by up to 20%. The implication is savings in both production downtime and general calibration costs. RTC-156/157 • Reference Temperature Calibrator www.jofra.com 3 NEW! -45˚C Only 10.5 kg NEW! NEW! Special designed carrying case SET-Follows-TRUE (model B & C only) AMETEK has designed an all-in-one-handle carrying case. Available on B and C models only, the “SET-Follows-TRUE” makes the instrument tune in until the temperature reading We have now made it possible to store both the STS refer- of the external reference “TRUE” meets the desired “SET” ence sensors and DLC sensors in the carrying case with an temperature. This feature is important when it is critical that optimum physical protection. There is room for inserts and the temperature of the calibration zone matches the desired insulation plugs to cover all dimensions and compartments temperature when measured with accurate external refer- for the new integrated support rod set, wires, manuals, cer- ence sensors. tificates, plugs, insert tools etc. Reading of sensor-under-test (model B only) All rooms are specially designed to hold one of the above Model B of the RTC is equipped with a built-in accu- mentioned items. This makes it very easy to keep track of rate measuring circuit for sensor-under-test (input), which any accessories. enables measurement of virtually any type of temperature sensors including: Resistance thermometers (RTD), ther- For optimum protection of the cali-brator and the accesso- mocouples (TC), transmitters, milliamps (mA), voltage (V) ries, the compartments are designed to hold the accessories and thermostats fixed during transportation. The RTC calibrators can be user-programmed from the Integrated support rod keyboard for fully automatic sensor calibrations. Once the The new integrated support rod is part unit is programmed, the instrument is self-operating and of the reduced weight philosophy. It is performs the configured calibration routine. All calibration lightweight and very easy to mount on data are stored and can be read in the display. the RTC. Two fixing holes are integrated in the calibrator where the support rods can be mounted. MVI - Secure temperature stability MVI stands for ’’Mains power Variance Immunity’’. Unstable mains power is a major contributor to on-site calibration inaccuracies. Traditional temperature calibra- tors often become unstable in production environments where large electrical motors, heating elements, and other devices are periodically cycled on or off. The cycling of sup- ply power can cause the temperature regulator to perform Switch test (model B only) inconsistently, leading to both inaccurate readings and unstable temperatures. Users may perform a thermoswitch test and find “Open”, “Closed” and the hysteresis (deadband) automatically. The The JOFRA RTC calibrators all employ the MVI functional- instrument retains the last twenty test results. ity, thus avoiding such stability problems. The MVI func- tionality is obtained by running the calibrator on stabilized Auto-stepping DC voltage. Up to 20 different temperature steps may be programmed including the hold time for each step. Upon completion of an auto step routine, the user can easily read the results for the sensor-under-test on the RTC display. Results from twenty auto-step calibrations are stored. The “Set temperature” feature allows the user to set the exact desired temperature with a resolution of 0.001°. Highest accuracy (model B & C only) The RTC series calibrators may be supplied with a built-in reference thermometer to be used with an external refer- ence sensor. This feature allows the instrument to perform calibrations on-site, while maintaining a high accuracy. A special 90° angled external reference sensor has been designed to accommodate calibration of sensors with a transmitter head, top connector or similar arrangement. The user can decide whether to read the built-in reference sensor or the more accurate angled reference sensor from the large, easy-to-read LCD display of the calibrator. The external sensor and the internal sensor readings are inde- pendent of one another. 4 www.jofra.com Reference Temperature Calibrator • RTC-156/157 NEW! JOFRACAL calibration software Enhanced stability A stability indicator shows when the RTC calibrator has JOFRACAL is a highly versatile calibration software that is reached the desired temperature and is stable. The user supplied together with the RTC calibrators. The software ensures easy calibration of all kind of temperature sen- may change the stability criteria for the external reference sors, such as RTD´s, thermocouples, transmitters and and the sensor-under-test quickly and simply. The stabil- thermoswithes. Furthermore, it can be used for pressure ity criterion is the user’s security of a correct calibration. A count-down timer is displayed next to the temperature calibration i.e. pressure gauges and pressure switches. read-out. JOFRACAL integrates with JOFRA calibration instruments. As for temperature calibrators, it is the whole range of temperature calibrators. Regarding pressure calibrators, it Instrument setups integrates with DPC-500, HPC and IPI pressure calibrators. The RTC series allows the user to store up to ten (10) com- JOFRACAL also has full integration with the series of signal plete instrument setups. You may store all sorts of informa- calibrators. tion including temperature units, stability criteria, use of external reference sensors, resolutions, sensors-under-test (SUT), conversions to temperature, display contrasts, etc. The setup may be recalled at any time. Maximum and minimum temperature From the setup menu, the user can select the maximum and minimum temperature limit for the calibrator. This func- tion prevents damage to the sensor-under-test caused by excessive temperatures and it helps reducing sensor drift from exposures of too high temperatures. This feature can be locked with an access code. JOFRACAL may also be used for manual calibrations, as it can be set up to accept manual entry of calibration data together Silent Operation with other liquid baths, ice points or dry-block heat sources. The RTC calibrator can be programmed to run in silent operation. This function is an advantage if calibrating in The calibration data collected can be stored on a PC for a laboratorie or in an office. If used in silent operation the later recall or analysis. The RTC calibrator stores the cali- calibrator is not using its full speed potential. bration procedure and may be taken out to the process site without bringing a personal computer. As found/As left (model B only) When running a calibration initiated from a work order, the This allows the RTC calibrator to: user can select the calibration as an As Found or an As Left • Operate as a stand-alone instrument, using advanced calibration. calibration routines without the assistance of a personal computer on site. The work order functionality • Prevent unauthorized changes to a calibration routine. SYNC output Personnel who are not authorized to alter a calibration A synchronization output signals when the instrument is routine cannot do so stable and may be used with ancillary devices such as video recorders, digital cameras or as an input to a data Once all calibrations are completed, the data may be up- logging device. The SYNC output may be useful for auto- loaded to the JOFRACAL for printing of certificates. The mating and documenting your calibrations when calibrating data collected may be stored on the personal computer for external reading devices. later recall or analysis. Calibration of indication devices JOFRACAL offers extended output formats of the cap- When calibrating an indicating device in the work order tured calibration data such as PDF file format and ASCII/ mode, users may key in the results during or after the test. semicolon separated text format for further processing and Using the “Calibration info” function, the user may view the calculation of data in spreadsheets and word processors. complete calibration task, including the “Scenario” before the calibration takes place. Calibration of up to 24 sensors with JOFRA ASM Hardware requirements Using the JOFRA RTC series together with the ASM, TM • INTEL 486 processor Advanced Signal Multi-scanner, offers a great time-saving TM • (PENTIUM 800 MHz recommended) automatic solution to calibrate multiple temperature sen- • 32 MB RAM (64 MB recommended) sors at the same time. The ASM series is an eight channel • 80 MB free disk space on hard disk prior to installation scanner controlled by the JOFRACAL software on a PC. Up • Standard VGA (800 x 600, 16 colors) compatible screen to 3 ASM units can be stacked to calibrate up to 24 sen- • (1024 x 786, 256 colors recommended) sors at a time. It can handle signals from 2-, 3- and 4 wire RTD’s, thermocouples, transmitters, temperature switches and voltage. RTC-156/157 • Reference Temperature Calibrator www.jofra.com 5 Free download www.jofra.com FUNCTIONAL SPECIFICATIONS INPUT SPECIFICATIONS All input specifications apply to the dry-block of the calibrator Temperature range running at the respective temperature (stable plus an additional RTC-156 20 minute period). @ ambient temp. 0°C/32°F ........-46 to 155°C/-51 to 311°F All input specifications are valid for RTC-156 and RTC-157. @ ambient temp. 23°C/73°F ......-30 to 155°C/-22 to 311°F @ ambient temp. 40°C/104°F ....-15 to 155°C/ 5 to 311°F RTC-157 RTD reference input (B & C models only) @ ambient temp. 0°C/32°F ........-57 to 155°C/-71 to 311°F 1) Type .................. 4-wire RTD with true ohm measurements @ ambient temp. 23°C/73°F ......-45 to 155°C/-49 to 311°F F.S. (Full Scale) ......................................................400 ohm @ ambient temp. 40°C/104°F ....-31 to 155°C/-24 to 311°F Accuracy (12 months) ...... ±(0.0012% rdg. + 0.0005% F.S.) RTD Type Temperature 12 months Accuracy (model B & C) with external STS ref. sensor °C °F °C °F RTC-156 B & C ......................................... ±0.04°C/±0.07°F -50 -58 ±0.008 ±0.015 Pt100 RTC-157 B & C ......................................... ±0.04°C/±0.07°F 0 32 ±0.008 ±0.015 reference 12-month period. Relative to reference standard. Specifications 155 311 ±0.011 ±0.019 by use of the external JOFRA STS-200 reference sensor Note 1: True ohm measurement is an effective method to eliminate errors from induced thermoelectrical voltage Accuracy with internal reference sensor RTC-156 A, B & C ..................................... ±0.10°C/±0.18°F DLC sensor input (B & C models only) RTC-157 A, B & C ..................................... ±0.10°C/±0.18°F Type Temperature 12 months Stability °C °F °C °F 1) RTC-156 ...............................................±0.005°C/±0.009°F -50 -58 ±0.014 ±0.025 DLC 155 1) RTC-157 ...............................................±0.005°C/±0.009°F 0 32 ±0.010 ±0.018 Measured after the stability indicator has been on for 15 minutes. 155 311 ±0.010 ±0.018 Measuring time is 30 minutes. RTD sensor under test input (B model only) Radial homogeneity (difference between holes) F.S. (range) .............................................................400 ohm RTC-156 .........................................................0.01°C/0.02°F Accuracy (12 months).................. ±(0.002% Rdg.+0.002% F.S.) RTC-157 .........................................................0.01°C/0.02°F F.S. (range) ...........................................................4000 ohm Accuracy (12 months) ........ ±(0.005% Rdg. + 0.005% F.S.) Resolution (user-selectable) 2-wire ............................................................add 50 mOhm All temperatures ......................1° or 0.1° or 0.01° or 0.001˚ RTD Type Temperature 12 months °C °F °C °F Heating time -50 -58 ±0.064 ±0.115 Pt1000 0 32 ±0.073 ±0.131 RTC-156 -30 to 23°C/-22 to 73°F ................. 4 minutes 155 311 ±0.076 ±0.136 23 to 155°C/73 to 311°F .............. 15 minutes -50 -58 ±0.115 ±0.191 Pt500 RTC-157 -45 to 23°C/-49 to 73°F ................. 7 minutes 0 32 ±0.127 ±0.228 23 to 155°C/73 to 311°F ................ 8 minutes 155 311 ±0.142 ±0.255 -50 -58 ±0.026 ±0.046 Pt100 Cooling time 0 32 ±0.026 ±0.046 RTC-156 155 to 100°C/311 to 212°F ............ 4 minutes 155 311 ±0.030 ±0.054 100 to 23°C/212 to 73°F ................ 8 minutes 23 to -24°C/73 to -11°F ............... 15 minutes -24 to -30°C/-11 to -22°F ............ 10 minutes RTC-157 155 to 100°C/311 to 212°F ............ 5 minutes 100 to 23°C/212 to 73°F .............. 10 minutes 23 to -30°C/73 to -22°F ............... 17 minutes -30 to -45°C/-22 to -49°F ............ 25 minutes Time to stability (approx.) RTC-156 ............................................................. 10 minutes RTC-157 ............................................................. 10 minutes Immersion depth RTC-156 ....................................................... 160 mm/6.3 in RTC-157 ....................................................... 160 mm/6.3 in 6 www.jofra.com Reference Temperature Calibrator • RTC-156/157 Thermocouple input Communication interface Range ..................................................................... ±78 mV Serial data interface .............................USB 2.0 device port F.S. (Full Scale) ......................................................... 78 mV Serial data interface ...................USB 2.0 host double port* Accuracy (12 months) ........ ±(0.005% Rdg. + 0.005% F.S.) LAN ...................................... Ethernet MAC 10/100 Base-T* SD ............................................................................ SD slot* TC Type Temperature 12 months* * for future expansion °C °F °C °F -50 -58 ±0.09 ±0.17 E Miscellaneous 0 32 ±0.06 ±0.11 155 311 ±0.06 ±0.11 Operating temperature ......................0 to 40°C/32 to 104°F -50 -58 ±0.10 ±0.18 J Storage temperature ....................... -20 to 50˚C/-4 to 122˚F 0 32 ±0.08 ±0.14 . Humidity ......................................................... 0 to 90% RH 155 311 ±0.09 ±0.16 Protection class ..........................................................IP-10 -50 -58 ±0.14 ±0.24 K 0 32 ±0.10 ±0.19 PHYSICAL SPECIFICATIONS 155 311 ±0.11 ±0.20 -50 -58 ±0.15 ±0.26 T 0 32 ±0.10 ±0.18 Weight and instrument size (L x W x H) 155 311 ±0.08 ±0.15 RTC-156/157 ................................................10.5 kg/23.2 lb -50 -58 ±1.30 ±2.35 R RTC-156/157 .......362 x 171 x 363 mm/14.3 x 6.7 x 14.3 in 0 32 ±0.78 ±1.40 155 311 ±0.47 ±0.84 -50 -58 ±0.98 ±1.76 S Shipping (without carrying case) 0 32 ±0.78 ±1.40 RTC-156/157 ................................................14.8 kg/32.6 lb 155 311 ±0.49 ±0.89 -50 -58 ±0.20 ±0.35 Size ......................570 x 235 x 440 mm/22.4 x 9.3 x 17.3 in N 0 32 ±0.15 ±0.27 155 311 ±0.13 ±0.23 -50 -58 ±0.09 ±0.15 XK Shipping (including optional carrying case) (only in Russian 0 32 ±0.06 ±0.11 RTC-156/157 ................................................20.5 kg/45.1 lb versions) 155 311 ±0.06 ±0.11 Size ....................650 x 380 x 500 mm/25.5 x 14.9 x 19.7 in -50 -58 ±0.13 ±0.24 U 0 32 ±0.10 ±0.18 155 311 ±0.08 ±0.14 Shipping (carrying case only) * Excl. CJC accuracy ±0.3˚C / ±0.54˚F Weight ............................................................8.0 kg/13.2 lb Size ....................650 x 380 x 500 mm/25.5 x 14.9 x 19.7 in Transmitter supply Output voltage ................................................24VDC ±10% Output current .......................................... Maximum 28 mA INSERTS Insert dimensions Transmitter input mA (B model only) RTC-156/157 outer diameter .....................29.7 mm/1.17 in Range ................................................................. 0 to 24 mA RTC-156/157 inner diameter (multi hole) ...25.6 mm/1.01 in Accuracy (12 months) ..........±(0.005% Rdg. +0.010% F.S.) RTC-156/157 inner diameter (single hole) .22.0 mm/0.87 in RTC-156/157 length ....................................150 mm/5.91 in Voltage input VDC (B model only) Weight of non-drilled insert (approx.) Range: .............................................................. 0 to 12 VDC Accuracy (12 months) ..........±(0.005% Rdg. +0.010% F.S.) RTC-156/157 ..................................................290 g/10.2 oz Switch input (B model only) Switch dry contacts Test voltage ...............................................Maximum 5 VDC Test current ..............................................Maximum 2.5 mA Mains specifications Voltage ...............................115V (90-127) / 230V (180-254) Frequency, non US deliveries ...............50 Hz ±5, 60 Hz ±5 Frequency, US deliveries .......................................60 Hz ±5 Power consumption (max.) ........................................400 W RTC-156/157 • Reference Temperature Calibrator www.jofra.com 7 PREDRILLED INSERTS FOR RTC-156/157 All predrilled inserts have holes for: 4 mm reference sensor • ¼” reference sensor • 3 mm hole for DLC sensor All inserts are supplied with an insulation plug drilled with the necessary holes Spare part no. for predrilled inserts with reference holes Instrument RTC-156/157 1 Sensor diameter Insert code A/B/C 3 mm 003 127312 4 mm 004 127313 5 mm 005 127314 6 mm 006 127315 7 mm 007 127316 8 mm 008 127317 9 mm 009 127318 10 mm 010 127319 11 mm 011 127320 12 mm 012 127321 13 mm 013 127322 14 mm 127323 014 15 mm 015 127324 16 mm 016 127325 Package of the above inserts SMM 127336 Spare part no. for predrilled inserts with reference holes Instrument RTC-156/157 1 Sensor diameter Insert code A/B/C 1/8 in 125 127302 3/16 in 187 127303 1/4 in 250 127304 5/16 in 312 127305 3/8 in 375 127306 7/16 in 437 127307 1/2 in 500 127308 9/16 in 562 127309 5/8 in 625 127310 Package of the above inserts SIM 127335 Note 1: Use the insert code, when ordering a JOFRA standard insert together with the RTC calibrator UNDRILLED INSERTS FOR RTC SERIES Inserts, undrilled incl. insulation plugs Instrument 1 Inserts Insert code RTC-156 A/B/C 5-pack, undrilled inserts with no holes UN1 127299 5-pack, undrilled inserts with hole for DLC sensor UN2 127300 5-pack, undrilled inserts with 2 holes for STS reference sensors 127301 UN3 (4mm & ¼”) and 1 hole for DLC sensor Undrilled insulation plug 122781 Note 1: Use the insert code, when ordering a JOFRA standard undrilled insert together with the RTC calibrator APPLICATION KIT FOR CALIBRATION OF SANITARY SENSORS Picture 1 shows a custom-made insert and our STS-102 A cable reference sensor placed in a RTC-156 calibrator. Picture 2 shows the sanitary sensor when fitted into the insert, ready for calibration. Note that the design makes room for the reference sensor cable. Complete STS102 application kit for RTC-156 model B and C including STS102A030EH, recalibration tube, 5-Pack undrilled flange insertion tubes with cable groove, and carrying case. Picture 1 Picture 2 Order No. 127279 8 www.jofra.com Reference Temperature Calibrator • RTC-156/157 MULTI-HOLE INSERTS FOR RTC-156/157 - METRIC (MM) All inserts are supplied with an insulation plug drilled with the necessary holes Spare part no. for multi-hole inserts - metric (mm) Instrument RTC-156/157 1/4” 1 Insert type Insert code A/B/C 4 mm Multi-hole type 1 M01 127329 3 mm Multi-hole type 2 M02 127330 Multi-hole type 3 M03 127331 4 mm 4 mm Multi-hole type 4 M04 127332 4 mm Multi-hole type 7 M07 127241 Multi-hole type 8 M08 127242 6 mm 4 mm Multi-hole type 9 M09 127243 Set of 4 Metric Multi Inserts, 3mm to 16mm SM 127326 Multi-hole M01 (Incl. 127332, 127241, 127242 and 127243) Note 1: Use the insert code, when ordering a JOFRA standard multi-hole insert together with the RTC calibrator 1/4” 1/4” 3 mm 3 mm 9 mm 12 mm 6 mm 8 mm 6 mm 4 mm 4 mm 4 mm 6 mm 4 mm 3 mm 1/4” 5 mm 3 mm 6 mm 6 mm 6 mm Multi-hole M04 Multi-hole M08 Multi-hole M02 1/4” 3 mm 3 mm 3 mm 11 mm 13 mm 10 mm 7 mm 3 mm 4 mm 4 mm 6 mm 4 mm 3 mm 3 mm 1/4” 3 mm 1/4” 3 mm 3 mm 3 mm Multi-hole M07 Multi-hole M09 Multi-hole M03 MULTI-HOLE INSERTS FOR RTC-156/157 - IMPERIAL (INCH) All inserts are supplied with an insulation plug drilled with the necessary holes Spare part no. for multi-hole inserts - imperial (inch) Instrument RTC-156/157 1 Insert code Insert code A/B/C Multi-hole type 5 M05 127327 Multi-hole type 6 M06 127328 Multi-hole type 10 M10 127247 Set of 3 Imperial Multi Inserts, 1/8 to 1/2 inch SI 127311 (Incl. 127308, 127328 and 127247) Note 1: Use the insert code, when ordering a JOFRA standard multi-hole insert together with the RTC calibrator 1/4” 3/8” 3 mm 7/16” 5/16” 1/4” 1/4” 1/8” 3/16” 1/4” 4 mm 4 mm 4 mm 3 mm 1/4” 1/4” 1/4” 3 mm 1/4” Multi-hole M05 Multi-hole M06 Multi-hole M10 RTC-156/157 • Reference Temperature Calibrator www.jofra.com 9 NEW! STANDARD DELIVERY OPTIONS Carrying Case - Option CT Model A, B and C: With our new special designed carrying case it is now • RTC dry-block calibrator (user specified) possible to store all your sensors in the case with an opti- • Mains power cable (user specified) mum physical protection. With improved integrated trolley • Traceable certificate - temperature performance system for easy and safe transportation. • Tool for insertion tubes • JOFRACAL • USB cable • Set of rubber cones for insulation plugs • Manual Model B instruments contain the following extra items: • Test cables (2 x red, 2 x black) • Traceable certificate - input performance for reference sensor and DLC sensor • Traceable certificate - input performance for sensor- under-test inputs Model C instruments contain the following extra items: Support rod set - Option SR • Traceable certificate - input performance for reference Support rod for sensors to be mount- sensor and DLC sensor ed on all JOFRA RTC dry-block cali- brators. Holds the sensor under test in ACCESSORIES its position, while calibrating. Includes 125066 Extra fixture for sensor grib 2 sensor grips and 2 fixtures for sen- 125067 Extra sensor grib sor gribs. 122771 Mini-Jack connector for stable relay output 120516 Thermocouple Male Plug - Type J - Black 120517 Thermocouple Male Plug - Type K - Yellow 120514 Thermocouple Male Plug - Type N - Orange 120515 Thermocouple Male Plug - Type T - Blue 120518 Thermocouple Male Plug - Type R / S - Green 120519 Thermocouple Male Plug - Type Cu-Cu - White Model A Model B Model C FUNCTIONAL COMPARISON Model A Model B Model C Dual-zone heating/cooling block • • • MVI - Mains Variance Immunity (or similar) • • • Stability indicator • • • Automatic step function • • • USB communication • • • Display resolution 0.001˚ • • • Programmable max. temperature • • • SYNC output (for external recording device) • • • Calibration of short sensors in special insert • • External precision reference sensor input • • External precision DLC reference sensor input • • “SET” follows “TRUE” • • Load compensation functionality • • Input for RTD, TC, V, mA • 4-20 mA transmitter input incl. 24 VDC supply • All inputs scalable to temperature • Automatic switch test (open, close and hysteresis) • Download of calibration work orders from PC • Upload of calibration results (as found & as left) • 10 www.jofra.com Reference Temperature Calibrator • RTC-156/157 ORDERING INFORMATION Order number Description Base model number RTC156 RTC-156 Series, -30˚C to 155˚C (-22˚F to 311˚F) RTC157 RTC-157 series, -45˚C to 155˚C (-49˚F to 311˚F) Model version A Basic model, without input B Full model, incl. DLC sensor input, Reference sensor input, Sensor-under-test input C Middle model, incl. DLC sensor input, Reference sensor input, Power supply (US deliveries 60 Hz only) 115 115VAC 230 230VAC Mains power cable A European, 230V B USA/Canada, 115V C UK, 240V D South Africa, 220V E Italy, 220V F Australia, 240V G Denmark, 230V H Switzerland, 220V I Israel, 230V Insert type and size NON No insert selected (standard) UNX 1 x Undrilled Insert (Please see Insert selection for code) XXX 1 x Single hole insert (Please see Insert selection for code) MXX 1 x Multi hole insert (Please see Insert selection for code) SIX Set of 3 Imperial multi hole inserts. Covering holes from 1/8” to 1/2” SMX Set of 4 Metric multi hole inserts. Covering holes from 3mm to 13mm SIM Set of 9 Imperial inserts. Covering holes from 1/8” to 5/8” SMM Set of 14 Metric inserts. Covering holes from 3mm to 16mm Dynamic Load Compensation (B & C models only, optional) DLC DLC sensor STS Reference sensor (B & C models only, optional) R1 STS-102 Ref. sensor. Dia. 4mm. Length 30mm (STS102A030EH) R2 STS-200 Ref. sensor. Dia. 4mm. Length 161mm (STS200A915EH) R3 STS-200 Ref. sensor. Dia. 1/4”. Length 161mm (STS200B915EH) Calibration Certificate F Traceable Callibration Certificate. (standard) H Accredited Calibration Certificate EA Full EURAMET Calibration Certificate FS Traceable System Calibration Certificate (B & C model only) HS Accredited System Calibration Certificate (B & C model only) EAS Full EURAMET System Calibration Certificate (B & C model only) EASD Full EURAMET System Calibration Certificate with DLC (B & C model only) Accessories CT Solid Protective Carrying case with trolley SR Support rod set TR Solid Protective Carrying case with trolley & Support rod set Sample order number JOFRA RTC-156 B with 230VAC, EU power cord, set of metric inserts, DLC, STS-200 ref. sensor, full EA temp. RTC156 B 230 A SM DLC R2 EA CT calibration certificate, and carrying case with trolley. RTC-156/157 • Reference Temperature Calibrator www.jofra.com 11 AMETEK Test & Calibration Instruments A business unit of AMETEK Measurement & Calibration Technologies Division offering the following industry leading brands for test and calibration instrumentation. JOFRA Calibration Instruments Temperature Calibrators Portable dry-block calibrators, precision thermometers and liquid baths. Temperature ranges from -90°C(-130°F) to 1205°C(2200°F). Temperature sensors for industrial and marine use. Pressure Calibrators Convenient electronic systems ranging from -25 mbar to 1000 bar - fully temperature-compensated for problem- free and accurate field use. Signal Instruments Process signal measurement and simulation for easy control loop calibration and measurement tasks. M&G Pressure Testers & Pumps Pneumatic floating-ball or hydraulic piston dead weight testers with accuracies to 0.015% of reading. Pressure generators delivering up to 1,000 bar. Lloyd Instruments Materials testing machines and software from Lloyd Instruments guarantees expert materials testing solutions. The comprehensive program also covers Texture Analysers to perform rapid, general food testing and detailed texture analysis on a diverse range of foods and cosmetics. Davenport Polymer Test Equipment Allows measurement and characterization of moisture- sensitive PET polymers and polymer density. Chatillon Force Measurement The hand held force gauges and motorized testers have earned their reputation for quality, reliability and accuracy and they represent the de facto standard for force measurement. Newage Testing Instruments Hardness testers, durometers, optical systems and software for data acquisition and analysis. www.jofra.com AMETEK Mansfield & Green (North America) T: +1 800 527 9999 | cal.info@ametek.com AMETEK Singapore Pte. Ltd. (Singapore) T: +65 6 484 2388 | aspl@ametek.com.sg AMETEK Inc. Beijing Rep. Office (China) AMETEK Denmark A/S T: +86 10 8526 2111 | jofra@ametek.com.cn Gydevang 32-34 | 3450 Allerød | Denmark AMETEK Instruments India Pvt Ltd. (India) T: +45 4816 8000 | ametek@ametek.dk T: +91 22 2836 4750 | ametek@ametek.dk AMETEK GmbH (Germany) T: +49 2159 9136 510 | info.mct-de@ametek.de AMETEK Calibration Instruments (UK) T: +44 (0) 1243 833 302 | jofra@ametek.co.uk Information in this document is subject to change without notice. ©2011, by AMETEK, Inc., www.ametek.com. All rights reserved. 12 www.jofra.com Pub code SS-RTC-156/157 Issue 1111

Related Products

AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 120515, Temperature calibrator Thermo...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 122822, Temperature calibrator, Clean...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 122832, Temperature calibrator, Clean...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS 125068, Temperature calibrator, Suppo...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, wide tempera...
AMETEK
AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, Reference Te...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 7.771 seconds.