Schneider electric RE8TA21BU industrial timing relay 3..300s - type A - 24 V
AC/DC, 110..240 V AC- 1 C/O

Part Number

RE8TA21BU

Price

Request Quote

Manufacturer

SCHNEIDER ELECTRIC

Lead Time

Request Quote

Category

Timers

Specifications

Current Maximum

3 A

Depth

80mm

Length

78mm

Maximum Operating Temperature

+60°C

Maximum Voltage

250 V

Minimum Operating Temperature

-20°C

Supply Voltage

110 ? 240 V ac, 24 V ac/dc

Time Delay

50 ms

Time Range

3 to 300 s

Width

22.5mm

Datasheet

pdf file

Schneider electric-RE8TA21BU-datasheet1-960527197.pdf

94 KiB

Extracted Text

Product data sheet RE8TA21BU Characteristics industrial timing relay - 3..300s - type A - 24 V AC/DC, 110..240 V AC- 1 C/O Main Range of product Zelio Time Product or component Optimum industrial timing relay type Component name RE8 Time delay type A Time delay range 3...300 s [Us] rated supply 110...240 V AC, 50/60 Hz voltage 24 V AC/DC, 50/60 Hz Sale per indivisible 1 quantity Complementary Discrete output type Relay Contacts material Silver nickel contacts Width pitch dimension 22.5 mm Voltage range 0.9...1.1 Us Connections - terminals Screw terminals 2 x 1.5 mm², flexible cablewith cable end Screw terminals 2 x 2.5 mm², flexible cablewithout cable end Tightening torque 0.6...1.1 N.m Setting accuracy of time delay +/- 20 % of full scale Repeat accuracy < 1 % Voltage drift < 2.5 %/V Temperature drift < 0.2 %/°C Minimum pulse duration 26 ms Reset time 50 ms Maximum switching voltage 250 V Mechanical durability 20000000 cycles [Ith] conventional free air thermal current 8 A [Ie] rated operational current <= 2 A at 24 V, DC-13 for 70 °C conforming to IEC 60947-5-1/1991 <= 2 A at 24 V, DC-13 for 70 °C conforming to VDE 0660 <= 3 A at 24 V, AC-15 for 70 °C conforming to IEC 60947-5-1/1991 <= 3 A at 24 V, AC-15 for 70 °C conforming to VDE 0660 <= 0.1 A at 250 V, DC-13 for 70 °C conforming to IEC 60947-5-1/1991 <= 0.1 A at 250 V, DC-13 for 70 °C conforming to VDE 0660 <= 0.2 A at 115 V, DC-13 for 70 °C conforming to IEC 60947-5-1/1991 <= 0.2 A at 115 V, DC-13 for 70 °C conforming to VDE 0660 Minimum switching capacity 10 mA at 12 V Marking CE Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage 250 V conforming to IEC 300 V conforming to CSA Supply disconnection value > 0.1 Uc Operating position Any position without derating factor Surge withstand 2 kV conforming to IEC 61000-4-5 level 3 Power consumption in VA 0.7 VA at 24 V 1.8 VA at 110 V 8.5 VA at 240 V Power consumption in W 0.5 W at 24 V Terminal description (15-16-18)OC_OFF (A1-B1)CO ALT 7/9/2011 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Height 78 mm Width 22.5 mm Depth 80 mm Product weight 0.11 kg Environment Immunity to microbreaks 3 ms Standards EN/IEC 61812-1 Product certifications CSA GL UL Ambient air temperature for storage -40...85 °C Ambient air temperature for operation -20...60 °C Relative humidity 15...85 % 3K3 conforming to IEC 60721-3-3 Vibration resistance 0.35 mm 10...55 Hz conforming to IEC 60068-2-6 Shock resistance 15 gn (duration = 11 ms conforming to IEC 60068-2-27 IP degree of protection IP20 (terminals) IP50 (casing) Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage 2.5 kV Non-dissipating shock wave 4.8 kV Resistance to electrostatic discharge 6 kV in contact conforming to IEC 61000-4-2 level 3 8 kV in air conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kV conforming to IEC 61000-4-4 level 3 Disturbance radiated/conducted CISPR11 group 1- class A CISPR22 - class A RoHS EUR status Compliant RoHS EUR conformity date 0624 2 Product data sheet RE8TA21BU Technical Description Function A: Delay on Energisation Description The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/ 2 timed outputs R2 R2 The second output is instantaneous if the right position is selected inst. T Timing period Ta Adjustable On-delay Tr Adjustable Off-delay U Supply 3 Product data sheet RE8TA21BU Dimensions Drawings Width 22.5 mm Rail Mounting Screw Fixing 4 Product data sheet RE8TA21BU Connections and Schema Internal Wiring Diagram Recommended Application Wiring Diagram 5 Product data sheet RE8TA21BU Performance Curves Performance Curves A.C. Load Curve 1 Electrical durability of contacts on resistive loading millions of operating cycles X Current broken in A Y Millions of operating cycles A.C. Load Curve 2 Reduction factor k for inductive loads (applies to values taken from durability curve 1). X Power factor on breaking (cos ϕ) Y Reduction factor k Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore 6 becomes:1.5 10 operating cycles x 0.6 = 900 000 operating cycles. D. C. Load Limit Curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 6

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the RE8TA21BU?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Schneider Electric LA2D20 0.1~3S On Delay Timer

Schneider Electric LA2-DT2 Timer Block; .01-30 Seconds Time Delay On

product

Schneider Electric RE11RAMU 24VAC/Dc-240VAC, 1CO On-Delay Timer

product

Schneider electric RE7TP13BU timer 300V 5 amp on delay