ALLEN-BRADLEY 1734-ADNX

Image of ALLEN-BRADLEY 1734-ADNX

Description

Allen Bradley 1734-ADNX Adapter Module - DeviceNet I/O Adapter with Expansion Port, 63 POINT I/O modules can be assembled on a single DeviceNet node

Part Number

1734-ADNX

Price

Request Quote

Manufacturer

ALLEN-BRADLEY

Lead Time

Request Quote

Category

I/O Module

Specifications

Dimensions

76.2 x 54.9 x 133.4 mm (3.00 x 2.16 x 5.25 in.)

Enclosure Type Rating

None (open-style)

Field side power requirements

400 mA @ 24V DC (+20% - 28.8V DC)

Input Voltage Range

10…28.8V DC

Input voltage, nom

24 V DC

Inrush Current

6 A for 10 ms

Interruption

Output voltage will stay within specifications when input drops out for 10 ms at 10V with max load.

Mounting Type

DIN-rail

Nonoperating Shock

50 g

Nonoperating Temperature

-40…85 °C (-40…185 °F)

Operating Shock

30 g

Operating Temperature

-20…55 °C (-4…131 °F)

POINTBus current

1000 mA

Power consumption at 24V

8.1W

Power dissipation, max

2.8 W @ 28.8V

Relative Humidity

5…95% noncondensing

Vibration

5 g at 10…500 Hz

Features

Datasheet

pdf file

Allen Bradley=1734-series=datashee-1046026930t.pdf

4939 KiB

Extracted Text

POINT I/O Selection Guide Catalog Numbers Bulletin 1734 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. IMPORTANT Identifies information that is critical for successful application and understanding of the product. ATTENTION Identifies information about practices or circumstances that can lead to: personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. SHOCK HAZARD Labels may be on or inside the equipment, such as a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment, such as a drive or motor, to alert people that surfaces may reach dangerous temperatures. Allen-Bradley, Rockwell Automation, POINT I/O, POINT Guard I/O, POINTBus, GuardLogix, , RSLogix 5000, DeviceLogix, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Table of Contents Chapter 1 POINT I/O Family Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 The POINT I/O System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 POINT I/O Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Specify a POINT I/O System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chapter 2 Select POINT I/O Communication Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 NetLinx Open Network Architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Interfaces Select a Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 EtherNet I/P Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ControlNet Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Memory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 DeviceNet Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 About the 1734D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 PROFIBUS DP Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Communication Adapter Environmental Specifications . . . . . . . . . . . 19 Chapter 3 Select POINT I/O Modules Select POINT I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Digital I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Digital AC Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Digital AC Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Digital DC Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Digital DC Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Digital Contact Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Digital POINTBlock AC/DC DeviceNet Adapters . . . . . . . . . . . 26 Digital I/O Modules Environmental Specifications . . . . . . . . . . . 26 Self Configurable Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Self Configurable Modules Environmental Specifications . . . . . . 27 Analog and Temperature I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . 28 Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Temperature Input Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Analog and Temperature I/O Modules Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Specialty I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 1734-232ASC and 1734-485ASC Serial Interface Modules. . . . . . 34 1734-SSI Synchronous Serial Interface Module with Absolute Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 1734-ARM Address Reserve Module . . . . . . . . . . . . . . . . . . . . . . . 37 1734-CTM Common Terminal and 1734-VTM Voltage Terminal Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Specialty I/O Modules Environmental Specifications. . . . . . . . . . 38 Counter Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Counter Modules Environmental Specifications . . . . . . . . . . . . . . 42 Safety I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 POINT I/O Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 vPublication 1734-SG001D-EN-P - September 2010 vi Table of Contents Chapter 4 Select a Terminal Base Assembly Terminal Base Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 One-piece Terminal Bases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Chapter 5 Select a Power Supply Unit POINT I/O Communication Adapters . . . . . . . . . . . . . . . . . . . . . . . . 51 Expansion Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Field Power Distributor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Chapter 6 Mounting Requirements Power Supply Distance Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Mount the POINT I/O System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Approximate Mounting Dimensions . . . . . . . . . . . . . . . . . . . . . . . 61 Chapter 7 Related Documentation Publication 1734-SG001D-EN-P - September 2010 Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design and operation. As a key element in the Rockwell Automation Integrated Architecture, its comprehensive diagnostics and configurable features allow the product to be easily applied to any automation system and reduce engineering costs through standardization. It can be used in remote device panels, local control panels, and can be accessed from many locations including the Internet. This product has just-what-you-need granularity in 1 to 8 points to reduce system cost and size. Available features include Channel Level Diagnostics for quick troubleshooting, multiple termination options and flexibility to save money, cabinet space and commissioning/troubleshooting time, the ability to mix/match Safety I/O on the same bus, and available DeviceLogix for local control, fast response time. Self-Configuring modules are also available to reduce/simplify your design and your inventory. 5Publication 1734-SG001D-EN-P - September 2010 6 POINT I/O Family The POINT I/O System B B A A C 45216 45215 1734-TOP or 1734-TOPS One-piece Terminal Base with Screw or Spring Clamp The base (A) mounts onto the DIN rail and provides the backplane. The POINT I/O module (B) snaps into the base. The removable terminal block (C) also snaps into the base and provides the wiring and terminations for field-side connections, as well as system power for the backplane. POINT I/O has 4 major components: • I/O modules provide the field interface and system-interface circuitry • Communication interface modules provide the network-interface circuitry • Terminal base units provide the wiring and signal termination for field-side connections and system power for the backplane • Power distribution modules provide the expandability of the POINT I/O system and the flexibility to mix a variety of signal types 1734 POINT I/O modules offer 1 to 8 points per module. The I/O modules are interfaced to a network through a communication interface, which includes a built-in power supply that converts incoming 24V DC power to 5V DC backplane power. Each type of communication interface (Network Adaptor) supports a maximum of 13 to 17 I/O modules, with a maximum of 10 A field power. The I/O modules receive power from the power supply through the backplane. With an external power supply, you can expand a POINT I/O assembly up to a maximum of 63 I/O modules or 504 channels. 1734D Series POINTBlock I/O provides a DeviceNet communication interface with up to 16 integrated I/O points in a single module. You can add up to 13 POINT I/O modules to a POINTBlock I/O assembly, for a maximum of 120 channels per assembly. Publication 1734-SG001D-EN-P - September 2010 POINT I/O Family 7 POINT I/O Features Adapters • ControlNet DeviceNet EtherNet I/P Profibus I/O TypesDigital Analog AC/DC Thermocouple RTD Specialty Module Density 1…8 points Specialty ModulesEncoder 1 MHz Counter In Counter In with Outputs Serial RS232 RS485 RS422 Channel Isolated Thermocouple RTD Serial Synchronous Interface (SSI) Address Reserve Module FeaturesChannel-level diagnostics (LED indicator and electronic) Channel-level alarm and annunciation (electronic) Channel-level open-wire detection with electronic feedback Channel-level short-circuit detection with electronic feedback Parameter-level explicit messaging Removal and insertion under power (RIUP) Horizontal or vertical mounting without derating Automatic Device Replacement Add-On-Profiles in RSLogix 5000 Network DeviceNet (including SubNet connectivity) Connectivity ControlNet (Logix controller only) EtherNet/IP (Logix controller only) PROFIBUS DP OPC/DDE Data Monitoring¨ Environmental Class I, Division 2/Zone 2, Marine Certification, European ATEX Zone Style 2 3G Modules per Node, Up to 63 max Publication 1734-SG001D-EN-P - September 2010 8 POINT I/O Family Specify a POINT I/O System Follow these steps as you specify your POINT I/O system: Step Remember to select 1 Select a communication • the appropriate interface module  interface • a communication interface that meets the power requirements of Choose the interface module for your your system operating system. 2 Select I/O devices based on • I/O modules - some have diagnostic  field devices features, electronic fusing, isolated inputs/outputs, and unique • location of the device configurable features • number of points needed • appropriate catalog number • number of points available per module • number of modules 3 Select a wiring base assembly • the appropriate wiring base  assembly: Choose the appropriate wiring base Single piece screw, single piece assembly spring, or RTB (Removable Terminal Base) 4 Select optional power • additional power components as  components necessary Choose optional components to • adequate power capacity to meet extend backplane power or change I/O module backplane current the field power distribution source. requirements 5 Determine mounting • the appropriate number of DIN rails  requirements based on the number of modules and the physical locations of those Determine needed dimensions based modules on the communication interface chosen. • horizontal or vertical mounting with no thermal derating Publication 1734-SG001D-EN-P - September 2010 Chapter 2 Select POINT I/O Communication Interfaces Step 1 - Select: • a communication interface module NetLinx Open Network Architecture....................................... page 9 EtherNet I/P Network................................................................ page 11 ControlNet Network.................................................................... page 12 DeviceNet Network..................................................................... page 15 PROFIBUS DP Network............................................................ page 18 Separate communication interface adapters are available for different Overview networks. Install adapters into the POINTBus backplane to allow POINT I/O modules to communicate with a controller. NetLinx Open Network Architecture is the Rockwell Automation NetLinx Open Network strategy of using open networking technology for seamless, top-floor Architecture to shop-floor integration. The NetLinx-based networks – DeviceNet, ControlNet, and EtherNet/IP – all use the Common Industrial Protocol (CIP), so they speak a common language and share a universal set of communication services. NetLinx architecture, part of the Integrated Architecture platform, seamlessly integrates all the components in an automation system from a few devices on one network to multiple devices on multiple networks including access to the Internet – helping you to improve flexibility, reduce installation costs, and increase productivity. • The EtherNet/IP network is an open industrial-networking standard that supports implicit and explicit messaging and uses commercial, off-the-shelf Ethernet equipment and physical media. • The ControlNet network allows intelligent, high-speed control devices to share the information required for supervisory control, work-cell coordination, operator interface, remote device configuration, programming, and troubleshooting. 9Publication 1734-SG001D-EN-P - September 2010 10 Select POINT I/O Communication Interfaces • The DeviceNet network offers low-cost, high-speed access to plant-floor data from a broad range of plant-floor devices and a significant reduction in wiring. Select a Network You can configure your system for information exchange between a range of devices and computing platforms and operating systems. Application requirements Network Select Plant management (material handling) EtherNet/IP 1734-AENT 1734-AENTR Configuration, data collection, and control on a single, high-speed network Time-critical applications with no established schedule Data sent regularly Internet/Intranet connection Close IT & Manufacturing Integration Built-in switch, or high availability requirement (2-port AENTR) High-speed transfer of time-critical data between controllers and I/O devices ControlNet 1734-ACNR Deterministic and repeatable data delivery Media redundancy Controller redundancy Intrinsic safety Connections of low-level devices directly to plant-floor controllers, without DeviceNet 1734-ADN interfacing them 1734-ADN(X) 1734-PDN Data sent as needed 1734D-series More diagnostics for improved data collection and fault detection Less wiring and reduced start-up time than a traditional, hard-wired system High noise resistance, and power over network Connecting to an existing PROFIBUS DP 5 m (16.4 ft) bus, 12 MB network PROFIBUS 1734-APB Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Communication Interfaces 11 The Ethernet Industrial (EtherNet/IP) network protocol is an open EtherNet I/P Network industrial-networking standard that supports both real-time I/O messaging and message exchange. It emerged due to the high demand for using the Ethernet network for control applications. The EtherNet/IP network uses off-the-shelf Ethernet communication chips and physical media. The EtherNet/IP network provides excellent drive and I/O control performance along with HMI information processing and many commercial technologies. EtherNet/IP Network Considerations Adapter Considerations 1734-AENT A total of 63 POINT I/O modules can be assembled on a single 1734-AENTR EtherNet/IP node. Expansion power supplies may be used to provide additional POINTBus backplane current. Refer to the User Manual to determine the ratings for direct and rack connections allowed. The 1734-AENT/1734-AENTR adapter supports direct- and rack-optimized connections. A direct connection is a real-time data transfer link between the controller and whatever module occupies the slot that the configuration data references. Direct-connection messaging occurs at a cyclic rate specified by the requested packet interval (RPI) during configuration. A rack-optimized connection is a grouping of data from more than one I/O module into a single block of data sent over a single connection at the same data rate. Rack-optimized connections reduce the total number of connections needed to transfer data when using many I/O modules in a system. Assume a system contains 8 digital I/O modules interfaced to a 1734-AENT/1734-AENTR adapter. If you used direct connections to transfer data to each of these modules, you need 8 connections — one to each of the 8 I/O modules. If you use a rack-optimized connection to transfer the Publication 1734-SG001D-EN-P - September 2010 12 Select POINT I/O Communication Interfaces data, you need only a single connection — the connection to the 1734-AENT/1734-AENTR adapter. 1 34 5 2 EtherNet/IP 12121345 45102 1734-AENT/1734-AENTR 1734-AENT/1734-AENTR Technical Specifications 1734-AENT/1734-AENTR Input Voltage, Nom. 24V DC Input Voltage Range 10…28.8V DC Field Side Power Requirements 400 mA @ 24V DC (+20% = 28.8V DC) Inrush Current 6 A for 10 ms POINTBus current (mA) 800 (1734-AENTR) 1000 (1734-AENT) Power Consumption at 24V 4.5 W Power dissipation, max. 2.8 W @ 28.8V Input Overvoltage Protection Reverse polarity protected Interruption Output voltage will stay within specifications when input drops out for 10 ms at 10V with max load. The ControlNet network is an open, state-of-the-art control network ControlNet Network that meets the demands of real-time, high-throughput applications. The ControlNet network uses the proven Common Industrial Protocol (CIP) to combine the functionality of an I/O network and a peer-to-peer network providing high-speed performance for both functions. The ControlNet network gives you deterministic, repeatable Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Communication Interfaces 13 transfers of all mission-critical control data in addition to supporting transfers of non-time-critical data. ControlNet Network Considerations Adapter Considerations 1734-ACNR A total of 63 POINT I/O modules can be assembled on a single ControlNet node. Expansion power supplies may be used to provide additional POINTBus backplane current. Up to 25 direct connections and 5 rack connections are allowed. The 1734-ACNR ControlNet adapter provides high-speed transfer of time critical data between controllers and I/O devices. It manages data transfers between controllers on the ControlNet network and POINT I/O modules plugged into the POINTBus backplane. The ControlNet network allows the exchange of messages between ControlNet products compliant with the ControlNet International specification. The 1734-ACNR adapter features include a variety of control system solutions, local communication network access through the network access port (NAP), and redundant media. It requires Series C POINT I/O modules or later. The 1734-ACNR adapter requires a typical 24V DC power supply with a maximum of 10.2 W of power. It provides a maximum backplane current of 1.0 A at 5V DC. Backplane current can be extended beyond 1.0 A with a 1734-EP24DC backplane extension power supply. The 1734-EP24DC can supply up to an additional 1.3 A of backplane current. Multiple 1734-EP24DC power supplies can be used to reach the maximum limit of 63 POINT I/O modules if 25 or fewer of these modules are analog or specialty modules. The adapter supports 25 direct and 5 rack I/O connections to the POINT I/O modules. From a single 1734-ACNR adapter, multiple controllers establish I/O connections, up to a maximum of 5 rack I/O connections per adapter. Direct connections must be used with analog and specialty modules. Multiple rack connections permit multiple controllers to connect to I/O over a single 1734-ACNR adapter. The number of connections that can be supported on a network depends on the ControlNet parameters (NUT, RPI, and API) and the POINT I/O configuration by itself (number and types of I/O modules). The following example shows a single POINT I/O ControlNet adapter with 5 connections and 8 I/O modules. The POINT I/O modules are monitored by the 5 controllers on the ControlNet network. The POINT I/O modules in: • slots 1, 3, and 5 are controlled by the first controller. • slots 2 and 4 by the second controller. • slot 6 by the third controller. • slot 7 by the fourth controller. Publication 1734-SG001D-EN-P - September 2010 14 Select POINT I/O Communication Interfaces • slot 8 by the fifth controller. 1 34 5 2 ControlNet 12121345 1734-ACNR Memory Requirements The 1734-ACNR adapter has 586 bytes of memory available for scheduled transmit data. When developing an application, the amount of data used by an individual connection must also include a small amount of overhead (I/O bytes per connection). The following formula tracks the amount of available scheduled transmit data. Available Memory = 586 - [(Number of connections * 10) + Sum of all connection sizes] In the following example, the system uses a 1734-ACNR adapter with five 1734-232ASC modules. Application Data Size Memory Required (number of bytes) 1734-232ASC - 1 100 110 1734-232ASC - 2 88 98 1734-232ASC - 3 96 106 1734-232ASC - 4 96 106 1734-232ASC - 5 92 102 Total Bytes Used 472 522 In this example, a sixth module could be added if it used less than 54 bytes of application data. There are 64 bytes of memory left. 64 = 586 - [(5 * 10) +472] Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Communication Interfaces 15 For more information about the 1734-ACNR adapter, see the POINT I/O ControlNet Adapter User Manual, publication 1734-UM008. 1734-ACNR Technical Specifications 1734-ACNR Input voltage, nom 24V DC Input voltage range 10…28.8V DC Field side power requirements 425 mA @ 24V DC (+20% = 28.8V DC) Inrush current 6 A for 10 ms (1) POINTBus current 1000 mA Power consumption at 24V 8.0 W Power dissipation, max. 2.8 W @ 28.8V Input overvoltage protection Reverse polarity protected Interruption Output voltage will stay within specifications when input drops out for 10 ms at 10V with max load. (1) 1000 mA @ 5V DC ±5% (4.75…5.25V). The DeviceNet network is an open low-level network that provides DeviceNet Network connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as PLC controllers and computers). The DeviceNet network uses the proven Common Industrial Protocol (CIP) to provide the control, configure, and data collection capabilities for industrial devices. The POINT I/O family offers four interfaces for connecting to the DeviceNet network. DeviceNet Network Considerations Adapter Consideration 1734-ADNAll POINT I/O modules count as a single node on the main network. A total of 63 POINT I/O modules can be assembled on a single DeviceNet node. Behaves as a slave device on the main network and a master on the POINTBus backplane. RSNetWorx for DeviceNet software is needed for configuration of the 1734-ADN adapter on the main network and the POINTBus backplane Expansion power supplies may be used to provide additional POINTBus backplane current. Publication 1734-SG001D-EN-P - September 2010 16 Select POINT I/O Communication Interfaces DeviceNet Network Considerations Adapter Consideration 1734-ADNXActs like a 1734-ADN adapter , with additional capabilities. All POINT I/O modules, and some third-party field devices, count as a single node on the main network. Has a second, Phoenix-style connector that extends the subnet off the module, so that any DeviceNet-capable device could be connected to a subnet and scanned by the 1734-ADNX adapter. Network on the second connector is electrically isolated from the main network and can be used to extend (1) the total DeviceNet trunk line distance. Node numbers of the devices on the POINTBus backp lane and subnet would not count against the 63 slave nodes allowed on the main network. Devices on the subnet and the main network need to be connected at different communication rates or use different sampling methods (for example, change-of-state or polled). Data from these devices would be included in the data being sent to/from the 1734-ADNX adapter on the main network. POINT I/O expansion power supplies are permitted and may be required to add more modules. 1734D POINTBlock Each POINT I/O module on the main network counts as a separate node. Series Appears to the main network as a 1734-PDN communication interface with a single, 16-point module attached. Any of the I/O modules may be attached in the same manner they are added to a 1734-PDN communication interface. Total POINTBus backplane current of I/O modules cannot exceed 1.0 A. Expansion power supplies may not be used. 1734-PDNEach POINT I/O module on the main network counts as a separate node. Electrically connects the main network to the I/O modules, which are connected on the POINTBus backplane. No configuration to the 1734-PDN communication interface necessary since it is transparent to the main network. Total POINTBus backplane current of I/O modules cannot exceed 1.3 A. Expansion power supplies may not be used. (1) For example: with thick round media at 125 Kbps, you could run a maximum of 500 m (1640 ft) to a 1734-ADNX adapter on the main network. You could then wire an additional 500 m (1640 ft) of cable on the subnet connector and double the distance of the network. Remember that this subnet needs terminating resistors and a 24V DC power connection, the same as any other DeviceNet network. It is important that the total amount of data coming from the subnet does not exceed the data capability of either the 1734-ADN or 1734-ADNX adapter. • 250 bytes (248 data + 2 bytes command info) for output data (used as either COS, cyclic, or poll) • 250 bytes (248 data + 2 bytes status info) for polled input data • 250 bytes (248 data + 2 bytes status info) for COS/cyclic input data • 8 bytes (6 data + 2 status info) for strobe input data The data coming through the 1734 adapter combined with the other data from the main network cannot exceed the data capability of the Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Communication Interfaces 17 main network master scanner. If this occurs, you will need multiple master scanners on the main network and the I/O modules on the subnet will need to be split between multiple 1734-ADN or 1734-ADNX adapters. With the 1734-PDN communication interface, the multiple masters on the main network will be able to communicate to separate groups of modules on its subnet through the same 1734-PDN communication interface, so no additional adapter would be necessary. About the 1734D Series The 1734D POINTBlock series is a set of DIN-rail mounted products with an integrated DeviceNet communication interface, various combinations of onboard I/O points, removable terminations, and a POINTBus expansion port. The DeviceNet interface presents the integrated I/O as a single DeviceNet node while expansion I/O modules will appear as separate nodes. The 1734D series includes a nonisolated DeviceNet communication interface. The 24V DC from the DeviceNet connection powers a nonisolated DC/DC converter that generates +5V DC. This +5V DC powers the 1734D series electronics and connects to the POINTBus port to power the expansion I/O electronics. See the Select POINT I/O Modules section of this document for POINTBlock I/O module catalog numbers and specifications. 1734 DeviceNet Adapters Technical Specifications 1734-PDN 1734D Series 1734-ADN/X Input voltage, nom 24V DC 10…28.8V DC 24V DC Input voltage range 11…25V DC DeviceNet 11…25V DC DeviceNet 10…28.8V DC specification specification Field side power 400 mA @ 24V DC (+4% = 350 mA @ 24V DC (+4% = 400 mA @ 24V DC (+20% = 28.8V requirements 25V DC) 25V DC) DC) Inrush current 6 A for 5 ms 6 A for 5 ms 6 A for 10 ms (1) (2) POINTBus current 1000 mA 1300 mA 1000 mA Power consumption at 24V 8.0 W 8.2 W 8.1 W Publication 1734-SG001D-EN-P - September 2010 18 Select POINT I/O Communication Interfaces 1734 DeviceNet Adapters Technical Specifications 1734-PDN 1734D Series 1734-ADN/X Power dissipation, max. 1.2 W @ 25V 2.0 W @ 24V 2.8 W @ 28.8V Input overvoltage Reverse polarity protected protection Interruption — — Output voltage will stay within specifications when input drops out for 10 ms at 10V with max load. (1) 1300 mA @ 5V DC ±5% (4.75…5.25V). (2) 1000 mA @ 5V DC ±5% (4.75…5.25V). PROFIBUS for Decentralized Peripherals is a standard in field bus PROFIBUS DP Network communication in automation. that helps eliminate hard wiring, and reduces costs associated with design and installation. PROFIBUS DP Network Considerations Adapter Considerations 1734-APB A total of 63 POINT I/O modules can be assembled on a single PROFIBUS DP node. Expansion power supplies may be used to provide additional POINTBus backplane current. Other considerations when using the APB adapter. Example, if needed (see EtherNet/IP section). 1734-APB Technical Specifications Attribute Value Input voltage, nom 24V DC Input voltage range 10…28.8V DC Field side power requirements 400 mA @ 24V DC (+20% = 28.8V DC Inrush current 6 A for 10 ms (1) POINTBus current 1000 mA Power consumption at 24V 8.0 W Power dissipation, max. 2.8 W @ 28.8V Input overvoltage protection Reverse polarity protected Interruption Output voltage will stay within specifications when input drops out for 10 ms at 10V with max load. (1) 1000 mA @ 5V DC ±5% (4.75…5.25V). Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Communication Interfaces 19 Communication Adapter Environmental Attribute Value Specifications Operating temperature -20…55° C (-4…131° F) Nonoperating temperature -40…85° C (-40…185° F) Relative humidity 5…95% noncondensing Operating shock 30 g Nonoperating shock 50 g Vibration 5 g @ 10…500Hz Enclosure type rating None (open-style) Mounting DIN Rail Certifications (when product is c-UL-us, Ex, CE , C-Tick , CI / EtherNet/IP / marked) DeviceNet Publication 1734-SG001D-EN-P - September 2010 20 Select POINT I/O Communication Interfaces Notes: Publication 1734-SG001D-EN-P - September 2010 Chapter 3 Select POINT I/O Modules Step 2 - Select: • I/O modules - some modules have diagnostic features, electronic fusing, or individually isolated inputs/outputs Digital I/O Modules.................................................................... page 22 Analog and Temperature I/O Modules.................................... page 28 Specialty I/O Modules ................................................................ page 34 Counter Modules.......................................................................... page 39 Safety I/O Modules ..................................................................... page 42 POINT I/O Accessories ............................................................ page 45 The POINT I/O family provides a wide range of input and output modules to Select POINT I/O Modules span many applications, from high-speed digital to process control. POINT I/O modules support producer/consumer technology, which allows input information and output status to be shared among multiple Logix controllers. 21Publication 1734-SG001D-EN-P - September 2010 22 Select POINT I/O Modules Each POINT I/O module mounts adjacent to the network adapter or another I/O module and removable terminal block (RTB) to connect all field-side wiring. The RTBs are part of the terminal base assembly. They are not included with the I/O modules and must be ordered separately. The POINT family of I/O modules includes: • 1734 digital I/O modules. • 1734 analog I/O modules. • 1734 specialty I/O modules. • 1734 wiring systems. • 1734 network communication adapters. • 1734 POINT Guard I/O modules. Choose digital I/O modules when you need: Digital I/O Modules • a wide variety of voltage interface capabilities • isolated and non-isolated module types • point-level output fault states • choice of direct-connect or rack-optimized communications • field-side diagnostics (on select modules) Most output modules have built-in surge suppression to reduce the effects of high-voltage transients. However, we recommend that you use an additional suppression device if an output is being used to control inductive devices, such as: •relays • motor starters • solenoids • motors Additional suppression is especially important if your inductive device is in series with or parallel to hard contacts, such as push buttons or selector switches. Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 23 Digital AC Input Modules 1734 Digital AC Input Modules Technical Specifications 1734-IA2 1734-IA4 1734-IM2 1734-IM4 Number of inputs 2 (1 group of 2) 2 (1 group of 4) 2 (1 group of 2) 2 (1 group of 4) Voltage, on-state input, nom 120V AC 220V AC Voltage, on-state input, min 65V AC 159V AC Voltage, on-state input, max 132V AC 264V AC (1) Input delay time, on to off 20 ms hardware filter plus 0…65 ms digital filter programmable in increments of 1 ms Current, on-state input, min 4.0 mA @ 65V AC, 60 Hz 6.2 mA @ 159V AC, 60 Hz Input impedance, nom 10.6 kΩ 22.3 kΩ Current, off-state input, max 2.7 mA @ 43V AC 2.9 mA POINTBus current 75 mA @ 5V DC Power dissipation, max 0.1 W @ 132V AC Thermal dissipation, max 3.4 BTU @ 132V AC Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS (1) Input ON-to-OFF delay time is the time from a valid input signal to recognition by the module. Digital AC Output Modules 1734 Digital AC Output Modules Technical Specifications 1734-OA2 1734-OA4 Number of outputs 2 4 Voltage, on-state output, nom 120V AC; 220V AC Voltage, on-state output, min 74V AC Voltage, on-state output, max 264V AC Output current rating 1.5 A (2 channels @ 0.75 A each) 2.0 A (750 mA per output, 2.0 A max per module) POINTBus current 75 mA @ 5V DC Power dissipation, max 2 W @ 264V AC 3.5 W @ 264V AC Thermal dissipation, max 6.8 BTU @ 264V AC 11.69 BTU @ 264V AC Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Publication 1734-SG001D-EN-P - September 2010 24 Select POINT I/O Modules Digital DC Input Modules 1734 Digital DC Input Modules Technical Specifications 1734-IB2 1734-IB4 1734-IB4D 1734-IB8 1734-IV2 1734-IV4 1734-IV8 Sinking Input Modules Sourcing Input Modules Number of inputs 2 4 4 8 2 4 8 Diagnostics ——Yes ———— Voltage, on-state input, nom 24V DC Voltage, on-state input, min 10V DC Voltage, on-state input, max 28.8V DC (1) Input delay time, on to off 0.5 ms hardware + (0…65 ms selectable) Current, on-state input, min 2 mA Current, on-state input, max 5 mA Current, off-state input, max 1.5 mA POINTBus current (mA) 75 mA max @ 5V DC 50 mA max 75 mA max @ 5V DC @ 5V DC Power dissipation, max 0.7 W @ 1.0 W @ 0.6 W max 1.6 W @ 0.7 W @ 1.0 W @ 1.6 W @ 28.8V DC 28.8V DC @ 28.8V DC 28.8V DC 28.8V DC 28.8V DC 28.8V DC Thermal dissipation, max 2.4 BTU/hr 3.4 BTU/hr 1.9 BTU/hr 5.5 BTU/hr 2.4 BTU/hr 3.4 BTU/hr 5.5 BTU/hr @ 28.8V DC @ 28.8V DC @ 28.8V DC @ 28.8V DC @ 28.8V DC @ 28.8V DC @ 28.8V DC Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS (1) Input ON-to-OFF delay time is the time from a valid input signal to recognition by the module. Digital DC Output Modules 1734 Digital DC Output Modules Technical Specifications 1734- 1734- 1734- 1734- 1734- 1734- 1734- 1734- 1734- 1734- (1) (1) (1) OB2E OB2EP OB4E OB8E OV2E OV4E OV8E OB2 OB4 OB8 Sourcing Output Modules Sinking Output Modules Number of 2 44 8 2 4 8 outputs Diagnostics — Yes Yes — Yes — Yes Yes Yes Yes Electronically Yes protected Voltage, 24V DC on-state output, nom Voltage, 10V DC on-state output, min Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 25 1734 Digital DC Output Modules Technical Specifications 1734- 1734- 1734- 1734- 1734- 1734- 1734- 1734- 1734- 1734- (1) (1) (1) OB2E OB2EP OB4E OB8E OV2E OV4E OV8E OB2 OB4 OB8 Voltage, 28.8V DC on-state output, max Output current 2.0 A per module, 4.0 A per 3.0 A per module, 1.0 A per channel 2.0 A max 3.0 A per 3.0 A per rating, max 1.0 A per channel module, per module, module, 2.0 A per module, 1.0 A per 1.0 A per channel 1.0 A per output channel output POINTBus 75 current (mA) Power 0.8 W @ 28.8V DC 3.4 W @ 1.2 W @ 28.8V DC 2.0 W @ 28.8V DC 0.8 W 1.2 W 2.0 W dissipation, 28.8V DC max @ max @ max @ max 28.8V DC 28.8V DC 28.8V DC Thermal 2.7 BTU/hr @ 28.8V 11.6 4.1 BTU/hr @ 28.8V 6.8 BTU/hr @ 28.8V 2.7 4.1 6.8 dissipation, DC BTU/hr @ DC DC BTU/hr @ BTU/hr @ BTU/hr @ max 28.8V DC 28.8V DC 28.8V DC 28.8V DC Terminal base 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS unit (1) Non-diagnostic, standard output modules. Digital Contact Modules 1734 Digital Contact Modules Technical Specifications 1734-OW2 1734-OW4 1734-OX2 Number of outputs 2 N.O. relays 4 N.O. relays 2 Form C (N.O./N.C.) relays, isolated (1) (1) Output delay time, on to off, max 26 ms 10 ms Contact resistance, initial 30 mΩ Leakage current, off-state 1.2 mA and bleed resistor through snubber circuit @ 240V AC 1.2 mA and bleed resistor through output, max snubber circuit @ 240V AC POINTBus current (mA) 80 100 Power dissipation, max 0.5 W Thermal dissipation, max 1.7 BTU/hr Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS (1) Time from valid output off signal to relay deenergization by module. Publication 1734-SG001D-EN-P - September 2010 26 Select POINT I/O Modules Digital POINTBlock AC/DC DeviceNet Adapters 1734 Digital POINTBlock AC/DC DeviceNet Adapters 1734D-IA16 1734D-IA8XOA8 1734D-IA8XOW8 1734D-IB16 1734D-IB8XOB8E 1734D-IB8XOW8 1734D-IA16S 1734D-IA8XOA8S 1734D-IA8XOW8S 1734D-IB16S 1734D-IB8XOB8ES 1734D-IB8XOW8S Number of 16 8 8 16 8 8 inputs Number of — 8 8 — 8 8 outputs Voltage, 120V AC 24V DC on-state input, nom Input delay 20.0 ms hardware + (0…65 ms selectable) 0.5 ms hardware + (0…65 ms selectable) time, on to off Current, 5.0 mA 2.5 mA on-state input, min Current, — 10 mA per output 10 mA per output — — 10 mA per output on-state output, min POINTBus 1000 current (mA) Power 2.0 W @ 24V DC dissipation, max Thermal 9.5 BTU/hr max @ 28.8V DC dissipation, max Digital I/O Modules Environmental Specifications 1734 Digital I/O Modules Environmental Specifications Attribute Value Operating temperature -20…55 °C (-4…131 °F) Nonoperating temperature -40…85 °C (-40…185 °F) Relative humidity 5…95% noncondensing Operating shock 30 g Nonoperating shock 50 g Vibration 5 g at 10…500 Hz Enclosure type rating None (open-style) Mounting type DIN-rail Certifications (when product is marked) CE, C-Tick, c-UL-us Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 27 Self Configurable Modules 1734 DC Configurable Input/Output Modules Technical Specifications 1734-8CFG 1734-8CFGDLX (with DeviceLogix Number of inputs/iutputs 8 8 Voltage, on-state input, nom Voltage, on-state input, min 11V AC Voltage, on-state input, max Current, on-state input, min 2.0 mA Current, on-state input, max 5.0 mA Input filter Each input independently settable in 1 ms intervals (truncated to 1 ms resolution). Default value is 1000 ms. Voltage, on-state output, nom 24V DC Voltage, on-state output, min 10V DC Voltage, on-state output, max 28.8V DC POINTBus current 100 mA @ 5V DC Power dissipation, max 2.6 W @ 28.8V DC Thermal dissipation, max 8.9 BTU/hr @ 28.8V DC Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Self Configurable Modules Environmental Specifications 1734 DC Configurable Input/Output Modules Environmental Specifications Attribute Value Operating temperature -20…55 °C (-4…131 °F) Nonoperating temperature -40…85 °C (-40…185 °F) Relative humidity 5…95% noncondensing Operating shock 30 g Nonoperating shock 50 g Vibration 5 g at 10…500 Hz Enclosure type rating None (open-style) Mounting type DIN-rail Certifications (when product is marked) CE, C-Tick Publication 1734-SG001D-EN-P - September 2010 28 Select POINT I/O Modules The POINT I/O analog and temperature I/O modules support: on-board, Analog and T emperature I/O channel-level data alarming (four set-points per channel); scaling to Modules engineering units; channel-level diagnostics (electronic bits and LED indicators); and integer format. Analog and temperature input modules support the following configurable parameters and diagnostics: • open-wire detection with LED and electronic reporting • four-alarm and annunciation set-points: low alarm; high alarm; low/low alarm; high/high alarm calibration mode detection and electronic reporting • under-range detection and electronic reporting • over-range detection and electronic reporting • channel signal range and on-board scaling (scaling to any 16-bit integer under-/over-range alarms) • filter type (notch for A/D, or first-order low-pass digital filter) • temperature scale (Celcius, Fahrenheit, Kelvin, Rankine, or custom) • channel update rate (step response plus 0…10,000 ms filter setting) Choose analog or temperature I/O modules when you need: • On-board scaling eliminates the need to scale the data in the controller, preserving controller processing time and power for more important tasks, such as I/O control, communications, or other user-driven functions. • Over- and under-range detections and indications eliminate the need to test values in the control program, saving valuable processing power of the controller. • Ability to individually configure each channel of the output module to hold its last value or assume a user-defined value on a fault condition. • Ability to individually enable and disable channels improves module performance. • Selectable input filters lets you select from several different filter frequencies for each channel that best meets the performance needs of your application based on environmental limitations • Selectable response to broken input sensor feature provides feedback to the controller that a field device is not connected or operating properly. This lets you specify corrective action based on the bit or channel condition. • The modules share a high accuracy rating of ±0.1% of full-scale accuracy at 25 °C (77 °F). Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 29 Analog Input Modules 1734 Analog Input Modules Technical Specifications 1734-IE2C 1734-IE2V 1734-IE4C 1734-IE8C Number of inputs 2 4 8 Input signal range 4…20 mA 0…10V 4…20 mA 4…20 mA 0…20 mA ±10V 0…20 mA 0…20 mA Input resolution 16 bits - over 21 mA 15 bits plus sign 16 bits - 0…21 mA 0.32 μA/cnt 320 μV/cnt in unipolar or 0.32 μA/cnt bipolar mode Data format Signed integer (1) Accuracy Current Input: 0.1% Full Voltage Input: 0.1% Full Current Input: 0.1% Full Scale @ 25 °C (1) (1) Scale @ 25 °C Scale @ 25 °C Accuracy drift w/temp. Current Input: 30 ppm/°C 5 ppm/°C 30 ppm/°C Step response, per 70 ms @ Notch = 60 Hz (default) 50 ms @ Notch = 60 Hz (default) channel 80 ms @ Notch = 50 Hz 60 ms @ Notch = 50 Hz 16 ms @ Notch = 250 Hz 30 ms @ Notch = 100 Hz 8 ms @ Notch = 500 Hz 25 ms @ Notch = 120 Hz 15 ms @ Notch = 200 Hz 12.5 ms @ Notch = 240 Hz 10 ms @ Notch = 300 Hz 7.5 ms @ Notch = 400 Hz 6.25 ms @ Notch = 480 Hz Input conversion type Delta Sigma Sigma Delta POINTBus current 75 mA @ 5V DC Power dissipation, max 0.6 W @ 28.8V DC 0.75 W @ 28.8V DC 0.6 W @ 28.8V DC Thermal dissipation, 2.0 BTU/hr @ 28.8V DC 2.5 BTU/hr @ 28.8V DC 2.0 BTU/hr @ 28.8V DC max Keyswitch position 3 Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS (1) Includes offset, gain, non-linearity and repeatability error terms. Publication 1734-SG001D-EN-P - September 2010 30 Select POINT I/O Modules Temperature Input Modules POINT I/O temperature modules can detect and communicate these electronic conditions: Over-range alarm • The channel over-range alarm is set if the input is greater than the maximum temperature (thermocouple or RTD range dependent), millivolt (+75V) or resistance (600 Ω) range value, or above the maximum range of the thermocouple or RTD. • The cold-junction compensator has its own over-range alarm. If the CJC temperature goes above 70 °C (158 °F), the over-range alarm is set. Under-range alarm • The channel under-range alarm is set if the input is less than the minimum temperature (thermocouple or RTD range dependent), millivolt (-75 mV) or resistance (10 Ω) range value, or below the minimum range of the thermocouple or RTD. • The cold-junction compensator has its own under-range alarm. If the CJC temperature goes below 0 °C (32 °F), the under-range alarm is set. Level alarm • When the channel input goes below a low alarm or above a (low-low, low, high, high alarm, a bit is set in the data table. All alarm status bits high-high) can be read individually or by reading the channel status byte (bits 2…5 for channel 0; bits 10…13 for channel 1). • Each channel alarm can be configured individually. Open-wire alarm • The module has the ability to check for a broken or detached wire. In any mode, if a broken/detached lead is detected, the data value is forced to maximum and the over-range alarm is set. Once the alarm is issued, it remains active as long as the input signal is faulted. Cold-junction Compensation (1734-IT2I only) When using thermocouples, cold-junction compensation is required at the termination of the thermocouple wire. Cold-junction can be accomplished in three ways: • Enter an estimated temperature • Use a 1734-TBCJC mounting base (recommended) • Use external cold-junction compensators Entering an estimated temperature is the least accurate way for cold-junction compensation. Using external compensators is the most expensive way, while using the 1734-TBCJC provides the easiest and most accurate method. An open cold-junction compensator causes the input point to the maximum temperature value for the selected input type. This causes an alarm to be set. Once the alarm is issued, it remains active as long as the input signal is faulted (above maximum). Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 31 Set the cold-junction enable bit on the 1734-IT2I module to enable or disable the cold-junction linearization. If enabled, the proper cold-junction compensation value is applied to the selected thermocouple. If disabled, the data (CJ temperature) is still available but is not applied to the input. If the 1734-TBCJC is not available, this parameter should be set to disabled. A cold-junction value can be added using the cold-junction offset parameter. Noise Filtering (1734-IR2) You can select the type and amount of noise filtering on each individual channel. • Notch filter of analog to digital converter • First-order, low-pass digital filter Choose the filter that provides you with the update and step response that most closely matches your system requirements. 1734 Analog Temperature Input Modules Technical Specifications 1734-IR2 1734-IR2E 1734-IT2I Number of inputs 2 RTD 2 high resolution RTD 2 thermocouple Input signal range 0…600 Ω 0…220 Ω ±75 mV Input resolution 16 bits 16 bits 15 bits + sign (1) 9.5 mΩ/cnt 2.4 mΩ/cnt 2.5 mV/cnt 0.03 °C/cnt (pt 385 @ 25 °C) 0.006 °C/cnt (Pt385 @ 25 °C) Data format Signed integer Thermocouple resolution — Type B, 30…1820 °C (86…3308 °F) 3 counts/°C Type C, 0…2315 °C (32…4199 °F) 6 counts/°C Type E, -270…1000 °C (-454…1832 °F) 24 counts/°C Type J, -210…1200 °C (-454…2192 °F) 21 counts/°C Type K, -270…1372 °C (-454…2502 °F) 13 counts/°C Type N, -270…1300 °C (-454…2373 °F) 11 counts/°C Type R, -50…1768.1 °C(-58…3214 °F) 4 counts/°C Type S, -50…1768.1 °C (-58…3214 °F) 4 counts/°C Type T, -270…400 °C (-454…752 °F) 15 counts/°C Cold junction compensation — Included in 1734-RTBCJC Remote Termination Block Cold junction compensation — 0…70 °C range Publication 1734-SG001D-EN-P - September 2010 32 Select POINT I/O Modules 1734 Analog Temperature Input Modules Technical Specifications 1734-IR2 1734-IR2E 1734-IT2I Accuracy Current Input: 0.1% Full Scale @ 25 °C Voltage Input: 0.1% Full Scale @ 25 °C Input update rate, per module 20 ms @ Notch = 50 Hz 17 ms @ Notch = 60 Hz (default) 10 ms @ Notch = 100 Hz 8 ms @ Notch = 120 Hz 5 ms @ Notch = 200 Hz 4 ms @ Notch = 240 Hz 3 ms @ Notch = 300 Hz 3 ms @ Notch = 400 Hz 2 ms @ Notch = 480 Hz Step response, per channel 60 ms @ Notch = 50 Hz 50 ms @ Notch = 60 Hz 30 ms @ Notch = 100 Hz 25 ms @ Notch = 120 Hz 15 ms @ Notch = 200 Hz 13 ms @ Notch = 240 Hz 10 ms @ Notch = 300 Hz 8 ms @ Notch = 400 Hz 6 ms @ Notch = 480 Hz Input impedance — 100 kΩ Input resistance — 1 MΩ Input conversion type Delta Sigma Common mode rejection ratio 120 dB Normal mode rejection ratio -100 dB, -3 dB -60 dB, -3 dB Notch filter: Notch filter: 13.1 Hz @ Notch = 50 Hz 13.1 Hz @ Notch = 50 Hz 15.7 Hz @ Notch = 60 Hz 15.7 Hz @ Notch = 60 Hz 26.2 Hz @ Notch = 100 Hz 26.2 Hz @ Notch = 100 Hz 31.4 Hz @ Notch = 120 Hz 31.4 Hz @ Notch = 120 Hz 52.4 Hz @ Notch = 200 Hz 52.4 Hz @ Notch = 200 Hz 62.9 Hz @ Notch = 240 Hz 62.9 Hz @ Notch = 240 Hz 78.6 Hz @ Notch = 300 Hz 78.6 Hz @ Notch = 300 Hz 104.8 Hz @ Notch = 400 Hz 104.8 Hz @ Notch = 400 Hz 125.7 Hz @ Notch = 380 Hz 125.7 Hz @ Notch = 380 Hz Overvoltage protection, inputs No input protection Input not overvoltage protected Input calibration Factory calibrated POINTBus current 220 mA @ 5V DC 175 mA @ 5V DC Power dissipation, max 1.0 W Thermal dissipation, max 3.3 BTU/hr Isolation voltage 50V (continuous), Basic Insulation Type Type tested at 2200V DC for 60 s, I/O to system External DC supply voltage, 24V DC — nom External DC supply voltage 10…28.8V DC — range Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 33 1734 Analog Temperature Input Modules Technical Specifications 1734-IR2 1734-IR2E 1734-IT2I External DC supply current, 15 mA @ 24V DC — nom Terminal base unit 1734-TBCJC 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 6 (1) Includes offset, gain, non-linearity and repeatability error terms. Analog Output Modules 1734 Analog Output Modules Technical Specifications 1734-OE2C 1734-OE2V 1734-OE4C Number of outputs24 Output signal range 4…20 mA 0…10V 4…20 mA 0…20 mA ±10V 0…20 mA Output resolution 13 bits - over 0…21 mA 14 bits (13 plus sign) 16 bits - over 0…21 mA 2.5 μA/cnt 1.28 mV/cnt in unipolar or 2.5 μA/cnt bipolar mode Data format Signed integer Accuracy Current output: 0.1% Full Scale Voltage output: 0.1% Full Scale Current output: 0.1% Full Scale (1) (1) (1) @ 25 °C @ 25 °C @ 25 °C Accuracy drift w/temp. Current output: 30 ppm/°C Voltage output: 5 ppm/ ºC Current output: <50 ppm/°C Step response to 63% of FS, Current output: 24 μs Voltage output: 20 μs Current output: 40 μs output Output conversion rate 16 μs 20 μs 1 μs POINTBus current 75 mA @ 5V DC Power dissipation, max 750 Ω load on each output - 1.0W 750 Ω load on each output - 1.23W 1.86W 0 Ω load on each output - 1.83W 0 Ω load on each channel - 2.15W Thermal dissipation, max 750 Ω load on each output - 3.4 BTU/hr 750 Ω load on each output - 4.19 BTU/hr 6.34 BTU/hr 0 Ω load on each output - 0 Ω load on each channel 7.33 BTU/hr 6.24 BTU/hr Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 4 (1) Includes offset, gain, non-linearity and repeatability error terms. Publication 1734-SG001D-EN-P - September 2010 34 Select POINT I/O Modules Analog and Temperature I/O Modules Environmental Specifications 1734 Analog and Temperature I/O Modules Environmental Specifications Attribute Value Operating temperature -20…55 °C (-4…131 °F) Nonoperating temperature -40…85 °C (-40…185 °F) Relative humidity 5…95% noncondensing Operating shock 30 g Nonoperating shock 50 g Vibration 5 g @ 10...500 Hz Enclosure type rating None (open-style) Mounting type DIN Rail Certifications (when product is marked) c-UL-us, CE, C-Tick, Ex 1734-232ASC and 1734-485ASC Serial Interface Modules Specialty I/O Modules The 1734-232ASC and 1734-485ASC serial interface modules offer a serial-link communication interface solution for peripheral products with RS-232 (use the 1734-232ASC), RS-485, and RS-422 ports (use the 1734-485ASC). These modules allow a device with serial-interface output (for example, bar code readers) to communicate up to 128 bytes of ASCII data onto any network supported by the POINT I/O system. Each module is a single-channel, full-duplex interface and is rated for up to 38.4 Kbps. LED indicators on the modules offer diagnostics for the module, POINTBus backplane, and transmit/receive status indication. 1734 Serial Interface Modules Technical Specifications 1734-232ASC, 1734-485ASC Number of serial channels 1 POINTBus current (mA) 75 Power dissipation 0.75 W @ 28.8V DC Thermal dissipation 2.5 BTU/hr max @ 28.8V DC Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 2 (specialty) Serial port parameters Serial character framing 7N2, 7E1, 7O1, 8N1, 8N2, 8E1, 8O1, 7E2, 7O2 Serial port comm speed 9600 bps, 1200 bps, 2400 bps, 4800 bps, 19.2 kbps, 38.4 kbps Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 35 1734 Serial Interface Modules Technical Specifications 1734-232ASC, 1734-485ASC Serial port receive from ASCII device Number of receive chars, max 1…128 ReceiverRecord start mode No, exclude, include start delimiter Receive start delimiter ASCII character Receive record end mode No, exclude, include end delimiter Receive end delimiter ASCII character Send (produce) on DeviceNet to Master Receive string data type Array, short_string, string Pad mode Pad mode disabled, enabled Pad character ASCII character Receive swap mode Disabled, 16-bit, 24-bit, 32-bit swap DeviceNet handshake mode Master/slave handshake, produce immediate Produce assembly size 4…132 Serial data size 0…128 bytes Receive transaction ID 0…255 Serial port transmit to ASCII device Number of transmit chars, max 1…128 Transmit end delimiter mode No, exclude, include end delimiter Transmit end delimiter character ASCII character Consume on DeviceNet from Master Consume string data type Array, short_string, string Transmit swap mode Disabled, 16-bit, 24-bit, 32-bit swap DeviceNet record header mode Transmit handshake/immediate Consume assembly size 4…132 Serial port transmit/explicit messages from configuration tool Transmit serial data string size 0…128 bytes Transmitted serial data length 0…128 bytes Transmit transaction ID 0…255 Status TX FIFO overflow, RX FIFO overflow, RX parity error, handshake error, new data flag 1734-SSI Synchronous Serial Interface Module with Absolute Encoder The 1734-SSI module collects serial data from industrial absolute-position encoding sensors that use standard SSI protocol. The SSI module is inserted Publication 1734-SG001D-EN-P - September 2010 36 Select POINT I/O Modules into a POINT I/O terminal base that provides common power, communications, and wiring connections for the SSI sensors. 1734-SSI Module Technical Specifications 1734-SSI Number of SSI channels 1 POINTBus current 110 mA Power dissipation, max 0.94 W Thermal dissipation, max — Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 2 Isolation voltage 50V (continuous), Basic Insulation Type Type tested at 1250V AC for 60 s, field side to system External DC supply voltage, nom 10…28.8V DC Encoder type Any absolute encoder supporting standard SSI protocol including linear, rotary, and optical distance measuring devices SSI data rate 125 kHz, 250 kHz, 500 kHz, 1 MHz, 2 MHz (software selectable) SSI bits per word 2…31 (software selectable) SSI word length 4 bytes (32 bits) (1) SSI word delay time 16 μs…64 ms (software selectable) SSI features Gray or binary code capable with gray to binary conversion, increasing or decreasing SSI count indication, 2 SSI word comparator values, SSI word latching with I1 input SSI cable type UL CM/AWM 2464/CSA Type CMG FT4 or similar cable utilizing shielded twisted pairs for D± and C± connections. See sensor manufacturer for actual cable required for the SSI sensor under use. I1 input can be wired separate from SSI cable. SSI cable length Depends on desired SSI data rate: 125 kHz…320 m(1050 ft) 250 kHz…160 m (525 ft) 500 kHz…60 m (195 ft) 1 MHz…20 m (65 ft) 2 MHz…8 m (25 ft) SSI sensor power (at V+/- terminals) 10…28.8V DC common with field power voltage, 0.75A DC maximum with short circuit protection SSI clock drive current, max (out of 750 mA C+/- terminals) Input I1 category/type Similar to IEC Type 3, sourcing Voltage, on-state input, min 0V DC Voltage, on-state input, max Field Power Supply Voltage minus 10V Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 37 1734-SSI Module Technical Specifications 1734-SSI Current, on-state input, min 2 mA Current, on-state input, nom 4 mA (Field Power Supply Voltage = 24V DC) Current, on-state input, max 5 mA Voltage, off-state input, min Field Power Supply Voltage minus 5V Voltage, off-state input, max Equal to Field Power Supply Voltage Current, off-state input, max 1.2 mA Input impedance, nom 3.6 kΩ Input impedance, max 4.7 kΩ Input filter time, nom 0.5 ms Field power supply voltage range 10…28.8V DC (1) Time between successive SSI words (Tp). Also called Dwell Time. 1734-ARM Address Reserve Module The 1734-ARM address reserve module reserves address and slot numbers to maintain the numbering schemes of purchased I/O module sets. Non-parameterized, signal modules' structure and address location are retained when replaced with a signal module. The 1734-ARM has no module configuration and does not communicate I/O data. 1734-ARM Module Technical Specifications 1734-ARM POINTBus current (mA) 75 Power dissipation, max 0.375 W @ 5V DC Thermal dissipation, max 1.3 BTU/hr @ 5V DC Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position Use the keyswitch position of the removed module 1734-CTM Common Terminal and 1734-VTM Voltage Terminal Modules The POINT I/O Common Terminal Module (1734-CTM) and Voltage Terminal Module (1734-VTM) provide expansion of the termination capability of POINT I/O. Install the Common and Voltage Terminal Modules on a 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS terminal base assembly to Publication 1734-SG001D-EN-P - September 2010 38 Select POINT I/O Modules provide support for higher density (8 channel) POINT I/O modules and management of wiring of field devices to the POINT I/O solution. 1734 Terminal Modules Technical Specifications 1734-CTM 1734-VTM POINTBus current (mA) — Power dissipation — Thermal dissipation — Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 5 Isolation voltage 250V (continuous), Basic Insulation Type Type tested at 1600V DC for 60 s, field-side to system Field power supply voltage range 10…28.8V DC, 120/240V AC Field power supply current, max 2 A per point, 4 A module Terminal base screw torque Determined by installed terminal block Field wiring terminations 0 - Common 0 - Voltage out 1 - Common 1 - Voltage out 2 - Common 2 - Voltage out 3 - Common 3 - Voltage out 4 - Common 4 - Voltage out 5 - Common 5 - Voltage out 6 - Common 6 - Voltage out 7 - Common 7 - Voltage out Specialty I/O Modules Environmental Specifications 1734 Specialty I/O Modules Environmental Specifications Attribute Value Operating temperature -20…55°C (-4…131°F) Nonoperating Temperature -40…85°C (-40…185°F) Relative humidity 5…95% noncondensing Operating shock 30 g Nonoperating shock 50 g Vibration 5 g @ 10…500 Hz Enclosure type rating None (open-style) Mounting type — Certifications (when product is marked) c-UL-us Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 39 The POINT I/O counter modules serve as signal conditioners and function Counter Modules blocks (that is, counters) between the customer process signals on the mounting base, and the POINTBus backplane containing the command information. The three main functional blocks are the customer digital I/O interface, the counter ASIC, and the microprocessor. The counter modules accept feedback from: • Encoders (either single-ended or differential) • Pulse generators • Mechanical limit switches • Frequencies up to 1 MHz A filter is available with four settings: 50 Hz, 500 Hz, 5 kHz, 50 kHz. The filter can be turned off to achieve the fastest counting rate. The modules return the count or frequency in the form of a 24-bit binary number (0…16,777,215) expressed in a 32-bit word. Each counter has a user-selectable preset and rollover value associated with it. The counter modules operate in the following modes. • Counter mode — read incoming single-phase pulses, return a binary count. • Encoder mode — read incoming two-phase quadrature pulses, return a binary count. • Period/rate mode — count internal clocks during the on period, return a frequency (1734-VHSC24 and 1734-VHSC5 outputs are updated only at the end of the period). • Continuous/rate mode — count internal clocks during the on period, return a frequency (1734-VHSC24 and 1734-VHSC5 outputs are updated continuously during this period). • Rate measurement mode — read pulses during the sample period, return a frequency. • Pulse width modulation (PWM) mode — generate a pulse width modulated signal (1734-VHSC24 and 1734-VHSC5 only). • Pulse generator mode — generates a pulse of defined width, returns width and quantity of trigger (1734-VHSC24 and 1734-VHSC5 only). The operation of the counter and encoder modes is nearly identical. The difference between the two modes is in the type of feedback (one-phase versus two-phase) for the count direction (up or down). In encoder mode, a transition is expected on B for counting to proceed in a direction. In counter mode, the Publication 1734-SG001D-EN-P - September 2010 40 Select POINT I/O Modules B input may be left at a static level. All operating modes are selected by writing appropriate configuration data to the module. 1734 Incremental Encoder Modules Technical Specifications 1734-IJ 1734-IK Number of counters 1 Input frequency, max 1.0 MHz counter and encoder X1 configurations (no filter) 500 kHz encoder X2 configuration (no filter) 250 kHz encoder X4 configuration (no filter) Voltage category/type, input 5V DC 24V DC A/Areturn, B/Breturn, Z/Zreturn A/Areturn, B/Breturn, Z/Zreturn Current, off-state input, max ≤ 0.250 mA ≤ 0.250 mA Voltage, off-state input, max ≤ 1.25V DC ≤ 1.8V DC Current, on-state input, min ≥5 mA Current, on-state input, max 25.7 mA @ 6V DC 19.1 mA @ 5V DC 6.1 mA @ 15V DC or 10.2 mA @ 24V DC Voltage, on-state input, min ≥2.6V DC ≥12.5V DC Voltage, on-state input, max ≤ 6V DC Refer to input derating curve Input filter selections, per A/B/Z group Off 10 μs (50 kHz) 100 μs (5 kHz) 1.0 ms (500 Hz) 10.0 ms (50 Hz) Power dissipation, max 1.1 W @ rated load 1.5 W @ rated load Thermal dissipation, max 3.75 BTU/hr @ rated load 5.1 BTU/hr @ rated load Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 2 Isolation voltage 50V (continuous), Basic Insulation Type Type tested at 1100V DC for 60 s, field-side to system External DC supply voltage, nom No additional external power required to power module 1734 VHSC Modules Technical Specifications 1734-VHSC24 1734-VHSC5 Number of counters 1 Number of compare windows 4 Output groups 1 group of 2 Voltage category/type, input 24V DC 5V DC Current, off-state input, max ≤ 0.250 mA ≤ 0.250 mA Voltage, off-state input, max ≤ 1.8V DC ≤ 1.25V DC Current, on-state input, min ≥5 mA Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 41 1734 VHSC Modules Technical Specifications Current, on-state input, max 10.2 mA @ 24V DC or 6.1 mA @ 15V DC 25.7 mA @ 6V DC 19.1 mA @ 5V DC Voltage, on-state input, min ≥12.5V DC ≥2.6V DC Voltage, on-state Input, max Refer to input derating curve ≥2.6V DC Input filter selections Off 10 μs (50 kHz) 100 μs (5 kHz) 1.0 ms (500 Hz) 10.0 ms (50 Hz) Input frequency, max 1.0 MHz counter and encoder X1 configurations (no filter) 500 kHz encoder X2 configuration (no filter) 250 kHz encoder X4 configuration (no filter) Output delay time off to on 25 μs (load dependent) Power dissipation, max 1.9 W @ rated load 1.5 W @ rated load Thermal dissipation, max 6.5 BTU/hr @ rated load 5.1 BTU/hr @ rated load Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS Keyswitch position 2 Isolation voltage 50V (continuous), Basic Insulation Type Type tested at 1100V DC for 60 s, field-side to system (1) External DC supply voltage, nom No additional external power required to power module (1) Does not represent power required to supply outputs. 1734-VHSC24 Input Derating Curve 113 °F Publication 1734-SG001D-EN-P - September 2010 42 Select POINT I/O Modules Counter Modules Environmental Specifications 1734 Counter Modules Environmental Specifications Operating temperature -20...55 °C (-4...131 °F) Nonoperating Temperature -40...85 °C (-40...185 °F) Relative humidity 5...95% non-condensing Operating shock 30 g Nonoperating shock 50 g Vibration 5 g @ 10…500 Hz Enclosure type rating None (open-style) Mounting type DIN Rail Certifications (when product is marked) c-UL-us, CE, C-Tick, Ex Use the POINT Guard I/O Safety Modules in the POINT I/O platform to Safety I/O Modules distribute Safety I/O on a GuardLogix, Compact GuardLogix or SmartGuard system. You can configure the modules by using the network configuration tool, RSNetWorx software, or the GuardLogix programming tool, RSLogix 5000 software, version 17 or later. GuardLogix systems are intended for the use of POINT Guard I/O modules with an EtherNet/IP adapter. SmartGuard systems are intended to use POINT Guard I/O modules with the 1734-PDN module. Use the modules to construct a safety-control network system that meets the requirements up to Safety Integrity Level 3 (SIL 3) as defined in IEC 61508, Functional Safety of Electrical, Electronic, and Programmable Electronic Safety-related Systems, and the requirements for Safety Category 4 / Performance Level e of the EN ISO 13849-1 standard. 1734-IB8S Technical Specifications Attribute Value Safety Input Inputs per module 8 Input type Current sinking Voltage, on-state input 11…30V DC Voltage, off-state input, max 5V DC Current, on-state input, min 3.3 mA Current, off-state, max 1.3 mA Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 43 1734-IB8S Technical Specifications Attribute Value IEC 61131-2 (input type) Type 3 Reaction time <16.2 ms Pulse Test Output Output type Current sourcing Number of sources (T0, T1M, T2, T3M) 4 Test output current (each output point) 0.7 A max Aggregate current of test outputs per module 2.8 A @ 40 °C (104 °F) 1734-IB8S temperature versus current derating for both horizontal and vertical installations 2.8 A 2.0 A -20 °C 40 °C 55 °C (-4 °F) (104 °F) (131 °F) Residual voltage, max 1.2V Output leakage current, max 0.1 mA Short circuit protection Yes Current, max 25 mA (when used to control muting lamp) (to avoid fault when used as a muted lamp output) Current, min 5 mA (when used to control muting lamp) (at which fault indication is generated when used as a muted lamp output) 1734-OB8S - Technical Specifications Attribute Value Safety Output Outputs per module 8 Output type Current sourcing Output current (each output point), max 1 A Residual voltage (drop) <0.6V Leakage current, max 0.1 mA Short-circuit detection Yes (short high and low and cross-circuit fault detect) Short-circuit protection Electronic Publication 1734-SG001D-EN-P - September 2010 44 Select POINT I/O Modules 1734-OB8S - Technical Specifications Attribute Value Aggregate current of outputs per module 8 A (4 A per terminal base) @ 40 °C (104 °F) 1734-OB8S temperature versus current derating for both horizontal and vertical installations 8 A 6 A 4 A -20 °C 40 °C 55 °C (-4 °F) (104 °F) (131 °F) Reaction time <6.2 ms 1734-IB8S and 1734-OB8S - Technical Specifications Attribute 1734-IB8S 1734-OB8S POINTBus POINTBus current, max 175 mA 190 mA Power dissipation 1.4 W 1.9 W Thermal dissipation 4.8 BTU/hr 6.5 BTU/hr Isolation voltage 50V (continuous), Basic Insulation Type between field side and system No isolation between individual channels Type tested at 707V DC for 60 s Power bus, operating supply voltage, nom 24V DC Power bus, operating voltage range 19.2…28.8V DC (1) 0…126 ms (in 6 ms increments) Input filter time, OFF to ON (1) Input filter time, ON to OFF Terminal base screw torque See terminal base specifications Indicators 1 yellow lock status indicator 1 green/yellow power status indicator 8 I/O channel status indicators (1) Input off-to-on filter time is the time from a valid input signal to recognition by the module. Input on-to-off time is the time from a valid input signal to recognition by the module. Publication 1734-SG001D-EN-P - September 2010 Select POINT I/O Modules 45 1734-IB8S and 1734-OB8S Physical Specifications Attribute Value Keyswitch positions (left and right) 1734-IB8S: Key 1 = 8 (left); Key 2 = 1 (right) 1734-OB8S: Key 1 = 8 (left); Key 2 = 2 (right) Terminal base unit 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS, 1734-TOP3, 1734-TOP3S Pilot duty rating Not rated (1734-OB8S only) North America temp code T4 IEC temp code T4 Enclosure type rating None (open-style) (1) 2 - on signal ports Wiring category Wire size Determined by installed terminal block Weight, approx. 62.4 g (2.2 oz) Dimensions (HxWxD), approx. (without terminal 77 x 25 x 55 mm (3.03 x 0.98 x 2.17 in.) block) (1) Use this conductor category information for planning conductor routing. Refer to the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. POINT I/O Marker Card POINT I/O Accessories The POINT I/O Marker Card is available under catalog number 1492-SM5X5. Each kit contains five 12.7 x 12.7 cm (5 x 5 in.) cards with 100 markers per card. You can enter text on the marker cards using different font sizes and text widths; you can print multiple lines on one marker card; you can even print common symbols. Publication 1734-SG001D-EN-P - September 2010 46 Select POINT I/O Modules POINTBus Extension Cable 45219 Module Module Module Module Module Module Module Status Status Status Status Status Status Status Network Network Network Network Network Network Network Status Status Status Status Status Status Status Mode Mode Mode Mode Mode Mode Mode RS232 RS232 RS232 RS232 RS232 RS232 RS232 ASCII ASCII ASCII ASCII ASCII ASCII ASCII TxD TxD TxD TxD TxD TxD TxD RxD RxD RxD RxD RxD RxD RxD Module Module Module Module Module Module Module Status Status Status Status Status Status Status Network Network Network Network Network Network Network Status Status Status Status Status Status Status Mode Mode Mode Mode Mode Mode Mode RS232 RS232 RS232 RS232 RS232 RS232 RS232 ASCII ASCII ASCII ASCII ASCII ASCII ASCII TxD TxD TxD TxD TxD TxD TxD RxD RxD RxD RxD RxD RxD RxD 45220 The POINT I/O POINTBus Extension Cable is available in 1 meter and 3 meter lengths as: • 1734-EXT1; 1 meter extension • 1734-EXT3; 3 meter extension Publication 1734-SG001D-EN-P - September 2010 Chapter 4 Select a Terminal Base Assembly Step 3 - Select: • the appropriate terminal base unit for your module Terminal Base Assembly............................................................. page 47 One-piece Terminal Bases.......................................................... page 49 The POINT I/O system follows a No Tools design approach. The I/O mounting base, removable terminal block (RTB), and I/O module may be assembled as a system without tools. The POINT I/O mounting base mounts directly on the DIN-rail, either Terminal Base Assembly vertically or horizontally, and forms the interconnect for the POINTBus backplane communication and field power-bus distribution. The mechanical keying of the mounting base prevents incorrect module placement. The I/O mounting base and removable terminal block are sold together (pre-assembled) as a single unit called a Terminal Base Assembly. The pins on the 1734-TB terminal base assembly are independent of each other. The connections for the 1734-TB and 1734-TB3 are determined by the 1734 module being used. Terminal Base Pins 1734-TB, -TBS, -TOP, -TOPS 1734-TB3, -TB3S, -TOP3, -TOP3S 0 1 0 1 2 3 2 3 4 5 4 5 67 67 45217 8 9 10 11 45218 Pins 4, 5, 8, and 9 are connected together. Pins 6, 7, 10, and 11 are connected together. 47Publication 1734-SG001D-EN-P - September 2010 48 Select a Terminal Base Assembly Each assembly includes a removable terminal block (RTB) provides 8 or 12 separate terminal locations for field wiring. The RTB also provides vertical access to wire and screw terminations. A separate terminal point is provided for each wire, including a shield ground terminal point for 2-point analog modules. POINT I/O Removable Terminal Base Assembly A B 45103 Each terminal base assembly includes a base (A) that mounts onto the DIN-rail and a removable terminal block (B) for I/O wiring. Once the RTB is wired properly, you never need to rewire terminations. The RTB separates independently of the I/O mounting base and I/O module to facilitate rapid installation and commissioning of the system. Each terminal is numbered on the bottom of the RTB to simplify troubleshooting during commissioning or maintenance cycles. Spare or replacement RTBs can be ordered separate from the terminal base assembly. Terminal Base Assemblies Terminal Base Description Terminal Base Replacement Assembly Screw Torque RTB Cat. No. Cat. No. 1734-TB Mounting base with 8-terminal 0.6 Nm 1734-RTB cage-clamp RTB (7 lb-in) 1734-TBS Mounting base with 8-terminal 1734-RTBS spring-clamp RTB 1734-TB3 Mounting base with 12-terminal 1734-RTB3 cage-clamp RTB 1734-TB3S Mounting base with 12-terminal 1734-RTB3S spring-clamp RTB (1) (1) Mounting base with cold-junction 0.5…0.6 Nm 1734-TBCJC 1734-RTBCJC compensation RTB (5…7 lb-in) (1) For use with the 1734-IT2I thermocouple input module. Publication 1734-SG001D-EN-P - September 2010 Select a Terminal Base Assembly 49 The POINT I/O one-piece terminal base is a mounting base with an One-piece Terminal Bases integrated terminal block. POINT I/O One-piece Terminal Base 1734 One-piece Terminal Bases Cat. No. Description Terminal Base Screw Torque 1734-TOP 8-terminal screw-clamp terminal base 0.6 Nm (7 lb-in) 1734-TOPS 8-terminal spring-clamp terminal base 1734-TOP3 12-terminal screw-clamp terminal base 1734-TOP3S 12-terminal spring-clamp terminal base Publication 1734-SG001D-EN-P - September 2010 50 Select a Terminal Base Assembly Notes: Publication 1734-SG001D-EN-P - September 2010 Chapter 5 Select a Power Supply Unit Step 4 - Select: • the appropriate power unit POINT I/O Communication Adapters ................................... page 51 Expansion Power Supplies.......................................................... page 52 Field Power Distributor............................................................... page 56 Power units are divided into three categories: • Communication adapter with built-in power supply (DC-DC) • Expansion power supply • Field power distributor POINT I/O communication adapters have built-in POINTBus power POINT I/O Communication supplies. All POINT I/O modules are powered from the POINTBus Adapters backplane by either an adapter or expansion power supply. 1734 Communication Adapters Power Specifications 1734-AENT(R) 1734-ACNR 1734-PDN 1734D Series 1734-ADN(X) 1734-APB Input voltage, 24V DC 24V DC 24V DC 10…28.8V DC 24V DC 24V DC nom Input voltage 10…28.8V DC 10…28.8V DC 11…25V DC 11…25V DC 10…28.8V DC 10…28.8V DC range DeviceNet DeviceNet specification specification Field side power 400 mA @ 24V 425 mA @ 24V 400 mA @ 24V 350 mA @ 24V 400 mA @ 24V 400 mA @ 24V requirements DC (+20% = DC (+20% = DC (+4% = 25V DC (+4% = 25V DC (+20% = DC (+20% = 28.8V DC) 28.8V DC) DC) DC) 28.8V DC) 28.8V DC Inrush current 6 A for 10 ms 6 A for 10 ms 6 A for 5 ms 6 A for 5 ms 6 A for 10 ms 6 A for 10 ms (1) (2) (3) (2) (2) (2) POINTBus current 700 1000 1300 1000 1000 1000 (mA) Power 4.5 W 8.0 W 8.0 W 8.2 W 8.0 W 8.0 W consumption at 24V 51Publication 1734-SG001D-EN-P - September 2010 52 Select a Power Supply Unit 1734 Communication Adapters Power Specifications 1734-AENT(R) 1734-ACNR 1734-PDN 1734D Series 1734-ADN(X) 1734-APB Power 2.8 W @ 28.8V 2.8 W @ 28.8V 1.2 W @ 25V 2.0 W @ 24V 2.8 W @ 28.8V 2.8 W @ 28.8V dissipation, max Input overvoltage Reverse polarity protected protection Interruption Output voltage will stay within — — Output voltage will stay within specifications when input drops out specifications when input drops out for 10 ms at 10V with max load. for 10 ms at 10V with max load. (1) 700 mA when input voltage < 17V DC. (2) 1000 mA @ 5V DC ±5% (4.75…5.25V). (3) 1300 mA @ 5V DC ±5% (4.75…5.25V). The 1734-EP24DC or 1734-EPAC expansion power supplies provides Expansion Power Supplies two services: • Breaks the field power distribution at the left of the power supply (1734-EP24DC or 1734-EPAC) from the field power distribution to the right of the power supply (1734-EP24DC or 1734-EPAC) • Adds an additional 1.3 A of current to the POINTBus for I/O modules to the right of the power supply (1734-EP24DC or 1734-EPAC) The expansion power unit maintains the integrity of the POINT I/O backplane by not interrupting the POINTBus data. The 1734-EP24DC expansion power unit passes 24V DC field power on the POINTBus backplane to the I/O modules to the right of it. The 1734-EPAC expansion power unit passes 120/240V AC field power on the POINTBus backplane to the I/O modules to the right of it. These units extend the backplane bus power and creates a new field voltage partition segment for driving field devices for up to 17 I/O modules. The expansion power units separate field power from I/O modules to the left of the unit, effectively providing functional and logical partitioning for: • separating field power between input and output modules. • separating field power to the analog and digital modules. • grouping modules to perform a specific task or function. You can use multiple expansion power units with the 1734-ADN, 1734-ADNX, 1734-ACNR, 1734-AENT, and 1734-APB communication adapters to assemble a full system. For instance, if you are using the Publication 1734-SG001D-EN-P - September 2010 Select a Power Supply Unit 53 1734-ADN adapter, you can use a 1734-EP24DC or 1734-EPAC expansion power unit to add additional modules. For example, if you have a 36 module system with a 1734-ADN adapter, you have to add at least two or more 1734-EP24DC or 1734-EPAC expansion power units to provide more POINTBus current for modules to the right of the supply. • 24…5V DC converter (1734-EP24DC) 120/240V AC to 5V DC converter (1734-EPAC) • 1.3 A, 5V DC output (extend backplane power) • Starts new voltage distribution • Partitioning • Dark-gray color for easy visual inspection and identification You can use the 1734-EP24DC or 1734-EPAC expansion power supply only with POINT I/O adapters. Do not use it with the 1734-PDN or 1734D series communication interfaces. 1734 Expansion Power Supplies Technical Specifications 1734-EP24DC 1734-EPAC Field side power 400 mA @ 24V DC (+20% = 28.8V DC max) 200 mA @ 120V AC, 100 mA @ 240V AC requirements, max Inrush current, max 6 A for 10 ms 2 A for 6 ms POINTBus output current Horizontal mounting: Horizontal DIN rail mounting: 1.3 A @ 5.2V DC rating 1 A @ 5V DC for 10…19.2V input Vertical DIN rail mounting: 1.0 A @ 5.2V DC 1.3 A @ 5V DC for 19.2…28.8V input Vertical mounting: 1 A @ 5V DC for 10…28.8V input Overvoltage protection, Reverse polarity protected MOV and fuse protected inputs PowersSupply Output voltage will stay within specifications Output voltage will stay within specifications when interruption protection when input drops out for 10 ms at 10V with input drops out for 10 ms at 85V with max load max load Power supply input 24V DC 120/240V AC voltage, nom Operating voltage range 10…28.8V DC 85…264V AC Power consumption, max 9.8 W @ 28.8V DC 15.1 W @ 264V AC Power dissipation, max 3.0 W @ 28.8V DC 8.4 W @ 264V AC Thermal dissipation, max 10.0 BTU/hr @ 28.8V DC 28.7 BTU/hr @ 264V AC Publication 1734-SG001D-EN-P - September 2010 54 Select a Power Supply Unit 1734 Expansion Power Supplies Technical Specifications 1734-EP24DC 1734-EPAC Isolation voltage 50V (continuous), Basic Insulation Type 264V (continuous), Reinforced Insulation Type Type tested at 2600V DC for 60 s, User power Type tested at 3250V DC for 60 s, User power to to system, User power to Chassis ground, system system to Chassis ground Field power supply 10…28.8V DC 120…240V AC voltage range Field power supply 10 A 10 A current, max 1734-EP24DC Current Derating for Mounting 1.3 1.0 Horizontal: 1 A @ 10…19.2V; 1.3 A @ 19.2…28.8V Current Vertical: 1 A @ 10…28.8V .0.5 10 19.2 28.8 Voltage 1734-EPAC Current Derating for Mounting 1.3 1.0 Current (A) Horizontal: 1.3 A 0.5 Vertical: 1 A 10 120 240 264 Voltage Publication 1734-SG001D-EN-P - September 2010 Select a Power Supply Unit 55 Example of Continuing Power to Field Devices DC Example of Logical Partitioning DC DC Publication 1734-SG001D-EN-P - September 2010 56 Select a Power Supply Unit Example of Functional Partitioning DC DC The 1734-FPD breaks the field power distribution at the left of the Field Power Distributor 1734-FPD from the field power distribution to the right of the 1734-FPD. You can use the 1734-FPD field power distributor with a broad range of voltage inputs including 5…125V DC and 24…240V AC applications and I/O modules. • Field-side voltage distribution module • AC or DC input • For use with all communication interfaces • Partitioning (auxiliary power, major motion, or minor motion) • Starts new voltage distribution point • No backplane bus power extension (12 modules maximum) when using the 1734-PDN communication interface or 1734D POINTBlock I/O modules as they don't add power to the POINTBus backplane The 1734-FPD field power distributor passes through all POINT I/O backplane signals, but does not provide additional POINTBus backplane power. The field power distributor gives you the ability to change the field power distribution source for I/O modules to the right of the 1734-FPD field power distributor. This facilitates logical or functional partitioning of low-channel count, high I/O-mix applications using any of the communication adapters. Publication 1734-SG001D-EN-P - September 2010 Select a Power Supply Unit 57 Use the 1734-FPD field power distributor to isolate field power segments. 1734-FPD Technical Specifications 1734-FPD Field side power requirements, max — Inrush current, max — POINTBus output current rating — Overvoltage protection, inputs — Power supply interruption protection — Power supply input voltage, nom 12V/24V DC 120V/220V AC Operating voltage range 10…28.8V DC 120V/240V AC Power consumption, max — Power dissipation, max — Thermal dissipation, max — Isolation voltage 250V (continuous), Basic Insulation Type Type tested at 2600V DC for 60 s, User power to system, User power to Chassis ground, system to Chassis ground Field power supply voltage range 10…28.8V DC, 120…264V AC Field power supply current, max 10 A Wiring Using a 1734-FPD to Create a New AC Device Power Bus Publication 1734-SG001D-EN-P - September 2010 58 Select a Power Supply Unit Wiring Using a 1734-FPD to Create a New Analog Device Power Bus DC Wiring Using a 1734-FPD to Create a New DC Device Power Bus DC Publication 1734-SG001D-EN-P - September 2010 Chapter 6 Mounting Requirements Step 5 - Select: • appropriate number of DIN rails based on the number of modules and the physical requirements Power Supply Distance Rating ................................................... page 59 Mount the POINT I/O System................................................. page 60 The producer/consumer model multicasts messages. This means that multiple nodes can consume the same data at the same time from a single device. Where you place POINT I/O modules in the control system determines how the modules exchange data. For a Rockwell Automation controller to control 1734 I/O, the I/O must be on one of the following: • the same network as the controller. • a ControlNet network that is local to that controller. • an EtherNet/IP network that is local to that controller. Place modules to the right of the power supply. Each 1734 I/O module can be Power Supply Distance placed in any of the slots right of the power supply until the usable backplane Rating current of that supply has been exhausted. An adapter provides 1000 mA current to the POINTBus backplane. The 1734-EP24DC or 1734-EPAC Expansion power supply provides up to 1300 mA. I/O modules require from 75 mA (typical for the digital and analog I/O modules) up to 220 mA or more. 59Publication 1734-SG001D-EN-P - September 2010 60 Mounting Requirements Use the following table to plan the maximum size layout of your POINT I/O system. Maximum Size Layout POINTBus current No. of I/O Modules No. of I/O Modules No. of I/O Module with 24V DC with Expansion Connections, max Backplane Current Power Supplies, (@ 75 mA each), max max 1734-PDN on 1300 mA Up to 17 Expansion power Not to exceed scanner DeviceNet network supply not allowed capacity 1734D POINTBlock 1000 mA Up to 13 Expansion power Not to exceed scanner on DeviceNet supply not allowed capacity network 1734-ADN(X) on 1000 mA Up to 13 63 Not to exceed scanner DeviceNet network capacity 1734-ACNR on 1000 mA Up to 13 63 5 rack and 20 direct ControlNet network 1734-AENT on 1000 mA Up to 13 63 20 total connections EtherNet/IP network including rack and direct 1734-APB on 1000 mA Up to 13 63 Not to exceed scanner PROFIBUS network capacity 1734-EP24DC Horizontal mounting: Up to 17 63 Not to exceed scanner Expansion Power 1000 mA @ 5V DC for 10…19.2V capacity 1300 mA @ 5V DC for 19.2…28.8V Vertical mounting: Up to 17 63 Not to exceed scanner 1000 mA @ 5V DC for 10…28.8V capacity 1734-EPAC Horizontal mounting: Up to 17 63 Not to exceed scanner Expansion Power 1300 mA@ 5.2V DC capacity Vertical mounting: Up to 17 63 Not to exceed scanner 1000 MA @ 5.2V DC capacity Mount the POINT I/O system on a DIN rail in the horizontal or vertical Mount the POINT I/O orientation. Use steel, 35 x 75.5 mm DIN rails (cat. no. 199-DR1; 46277-3; EN System 50022). The DIN rails for all POINT I/O system components must be mounted on a common, conductive surface to ensure proper electro-magnetic interference (EMI) performance. Secure DIN rail approximately every 200 mm (7.87 in). Publication 1734-SG001D-EN-P - September 2010 Mounting Requirements 61 Approximate Mounting Dimensions POINT I/O with 1734-PDN Mounting Dimensions Allow a 25.4 mm (1.0 in) air gap all around 133.4 mm (5.25 in) 1734-PDN (H x W x L) 7.62 x 25.4 x 133.4 mm 1734-TB or 1734-TBS with I/O (H x W x L) 65 x 12 x 133.4 mm (3.00 x 1.00 x 5.25 in) (2.56 x 0.47 x 5.25 in) 1734-FDN (H x W x L) 7.62 x 25.4 x 133.4 mm (3.00 x 1.00 x 5.25 in) 1734D POINTBlock Mounting Dimensions Allow a 25.4 mm (1.0 in) air gap all around 133.4 mm (5.25 in) 1734D (H x W x L) 7.62 x 60.0 x 133.4 mm (3.00 x 2.36 x 5.25 in) Publication 1734-SG001D-EN-P - September 2010 62 Mounting Requirements POINT I/O with 1734-ADN(X), 1734-ACNR, 1734-AENT, 1734-APB Mounting Dimensions Allow a 25.4 mm (1.0 in) air gap all around 133.4 mm (5.25 in) 1734-ADN (H x W x L) 1734-TB or 1734-TBS with I/O (H x W x L) 7.62 x 54.9 x 133.4 mm 65 x 12 x 133.4 mm (3.00 x 2.16 x 5.25 in) (2.56 x 0.47 x 5.25 in) 1734-EP24DC or 1734-FPD (H x W x L) 7.62 x 25.4 x 133.4 mm (3.00 x 1.00 x 5.25 in) Publication 1734-SG001D-EN-P - September 2010 Chapter 7 Related Documentation These documents contain additional information concerning related Rockwell Automation products. You can view or download publications at http://literature.rockwellautomation.com. To order paper copies of technical documentation, contact your local Rockwell Automation distributor or sales representative. Cat. No. Description General Information DeviceNet Media (Media, Sensors and Distributed I/O) Catalog Guide DeviceNet Adapter Quick Start ControlNet Media EtherNet/IP Performance and Application Guide Industrial Automation Wiring and Grounding Guidelines Allen-Bradley Terminal Marking System Product Profile Communication 1734-ADN(X) POINT I/O DeviceNet Adapter Module Installation Instructions, publication 1734-IN026 Interfaces POINT I/O DeviceNet Adapter Module User Manual, publication 1734-UM002 1734-PDN POINT I/O DeviceNet Communication Interface Module Installation Instructions, publication 1734-IN057 1734-AENT POINT I/O Ethernet Adapter Installation Instructions, publication 1734-IN590 POINT I/O EtherNet/IP Communication Adapter Module User Manual, publication 1734-UM010 1734-AENTR POINT I/O 2 Port EtherNet/IP Adapter Installation Instructions, publication 1734-IN040 POINT I/O 2 Port EtherNet/IP Adapter Installation Instructions, publication 1734-UM014 1734-ACNR POINT I/O ControlNet Adapter Installation Instructions, publication 1734-IN582 POINT I/O ControlNet Adapter User Manul, publication 1734-UM008 1734-APB POINT I/O PROFIBUS Adapter Module Installation Instructions, publication 1734-IN014 POINT I/O PROFIBUS Adapter Module User Manual, publication 1734-UM005 Digital and Analog 1734 Series POINT I/O Digital and Analog Modules User Manual, publication 1734-UM001 AC 1734-IA2 120V AC 2 Input Module Installation Instructions, publication 1734-IN010 1734-IA4 1734-IM2 220V AC 2 Input Module Installation Instructions, publication 1734-IN008 1734-IM4 1734-OA2 120/220V AC 2 Output Module Installation Instructions, publication 1734-IN009 1734-OA4 63Publication 1734-SG001D-EN-P - September 2010 64 Related Documentation Cat. No. Description DC 1734-IB2 24V DC 2, 4, or 8 Input Sink Module Installation Instructions, publication 1734-IN051 1734-IB4 1734-IB8 1734-IB4D POINT I/O 24V DC 4-Channel Discrete Input Module Installation Instructions, publication 1734-IN029 1734-IV2 24V DC 2, 4, or 8 Input Source Module Installation Instructions, publication 1734-IN052 1734-IV4 1734-IV8 1734-OB2E POINT I/O Protected Output Module Installation Instructions, publication 1734-IN056 1734-OB4E 1734-OB8E 1734-OB2EP POINT I/O Protected Output Module Installation Instructions, publication 1734-IN586 1734-OB2 POINT I/O Protected Output Module Installation Instructions, publication 1734-IN018 1734-OB4 1734-OB8 1734-OV2E POINT I/O Protected Sink Output Module Installation Instructions, publication 1734-IN585 1734-OV4E 1734-OV8E Analog 1734-IE2C POINT I/O 2 Current and 2 Voltage Input Analog Modules Installation Instructions, publication 1734-IE2V 1734-IN027 1734-IE4C POINT I/O 4 Channel High Density Current Input Module Installation Instructions publication 1734-IN032 1734-IE8C POINT I/O 8 Channel High Density Current Input Module Installation Instructions publication 1734-IN033 1734-OE2C 24V DC Analog 2 Channel Current Output Module Installation Instructions, publication 1734-OE2V 1734-IN002 1734-OE4C POINT I/O 4 Channel Analog Current Output Module Installation Instructions, publication 1734-IN034 1734-IR2 POINT I/O RTD and Isolated Thermocouple Input Modules Installation Instructions, publication 1734-IR2E 1734-IN011 1734-IT2I Serial Interface 1734-232ASC/ RS-232, -422, and -485 ASCII Modules Installation Instructions, publication 1734-IN388 Modules 1734-485ASC RS-232, -422, and -485 ASCII Modules User Manual, publication 1734-UM009 1734-SSI Synchronous Serial Interface Module with Absolute Encoder Installation Instructions, publication 1734-IN581 Synchronous Serial Interface Module with Absolute Encoder User Manual, publication 1734-UM007 1734-IK 5V and 24V Encoder/Counter Modules Installation Instructions, publication 1734-IN005 1734-IJ 5V and 24V Encoder/Counter Module User Manual, publication 1734-UM006 1734-VHSC5 5V and 24V DC Very High Speed Counter Module Installation Instructions, publication 1734-VHSC24 1734-IN003 5V and 24V DC Very High Speed Counter Module User Manual, publication 1734-UM003 Publication 1734-SG001D-EN-P - September 2010 Related Documentation 65 Cat. No. Description Bases 1734-TB, Wiring Base Assembly with 8 Point Cage-Clamp Removable Terminal Block Installation 1734-TBS Instructions, publication 1734-IN511 1734-TBS, Wiring Base Assembly with 12 Point Cage-Clamp Removable Terminal Block Installation 1734-TB3S, Instructions, publication 1734-IN013 1734-RTBS, 1734-RTB3S 1734-TOP, POINT I/O One-piece Terminal Bases Installation Instructions, publication 1734-IN028 1734-TOPS, 1734-TOP3, 1734-TOP3S 1734-TBCJC Cold Junction Compensation Wiring Base Assembly Installation Instructions, publication 1734-IN583 Power Units 1734-FPD Field Potential Distributor Module Installation Instructions, publication 1734-IN059 1734-EP24DC 24V DC Expansion Power Supply Installation Instructions, publication 1734-IN058 1734-EPAC 120/240V AC Expansion Power Supply Installation Instructions, publication 1734-IN017 Safety 1734-IB8S, POINT Guard I/O Safety Modules Installation and User Manual, publication 1734-UM013 1734-OB8S Publication 1734-SG001D-EN-P - September 2010 66 Related Documentation Notes: Publication 1734-SG001D-EN-P - September 2010 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support/. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Use the Worldwide Locator at http://www.rockwellautomation.com/support/americas/phone_en.html, or contact Canada your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 1734-SG001D-EN-P - September 2010 68 Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 1734-ADNX?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Rockwell Automation 1734-232ASC Serial I/O Modules- Inputs/Outputs 1 Serial Interface channel, Point...

product

Rockwell Automation 1734-485ASC Serial I/O Modules- Inputs/Outputs 1 Serial Interface channel, Point...

product

Allen Bradley 1734-ADN I/O Adapter Module - 24V DC DeviceNet Adapter

product

Allen Bradley 1734d-IA16 PointBlock I/O Module - 120 VAC, 16 Inputs, DNET communication interface

product

Allen Bradley 1734d-IA16S PointBlock I/O Module - 120 VAC, 16 Inputs, DNET communication interface, ...

product

Allen Bradley 1734D-IA8XOW8 PointBlock I/O Module - 120 VAC 8 Inputs 8 Relay Outputs, DNET Communica...