ALLEN-BRADLEY 1734D-IA16S

Image of ALLEN-BRADLEY 1734D-IA16S

Description

Allen Bradley 1734d-IA16S PointBlock I/O Module - 120 VAC, 16 Inputs, DNET communication interface, spring clamp terminals

Part Number

1734D-IA16S

Price

Request Quote

Manufacturer

ALLEN-BRADLEY

Lead Time

Request Quote

Category

I/O Module

Specifications

Agency Certification (when product is marked)

C-UL Listed, C-UL Class I, Division 2 Groups A, B, C and D certified, UL listed, UL Class I, Division 2 Groups A, B, C and D certified, CE marked for all applicable directives, C-Tick marked for all applicable acts

Conductors Wire Size Category

14 AWG (2.5mm2) - 22 AWG (0.25mm2) solid or stranded copper rated @ 75°C or greater, 3/64 inch (1.2mm) insulation max, 21

DeviceNet Current

95mA maximum for POINTBlock, 350mA for maximum with expansion of

Dimensions Inches(Millimeters)

3.00H x 2.36W x 5.25L(76.2 Hx 60.0W x 133.4L)

External AC Power Supply Voltage

120V ac, 60Hz nominal

External AC Power Supply Voltage Range

85-132V ac, 47-63Hz

Field Wiring Terminations DeviceNet

1 - Black Wire -V, 2 - Blue Wire: CAN Low, 3 - Bare Wire: Drain, 4 - White Wire :CAN High, 5 - Red Wire: +V

Field Wiring Terminations Field Power Supply

0 - No Connection1 - No Connection, 2 - No Connection3 - No Connection, 4 - AC return 5 - AC return, 6 - AC power 7 - AC power

Indicators

1 red/ green module status indicator, 1 red/green network status indicator

Input Filter Time OFF to ON

20.0ms hardware + (0 - 65ms selectable)

Input Filter Time ON to OFF

20.0ms hardware + (0 - 65ms selectable)

Isolation Voltage

2104V dc for 1s between user power and DeviceNet

Mass

13.88 oz/393.50 grams

Nominal Input Impedance

17.0kW

Non-operating

50g peak acceleration, 11(±1)ms pulse width

Number of Channels

16 input channels

Number of POINT I/O Expansion Modules

12 maximum added at expansion port

OFF-State Current

2.5mA max

OFF-State Voltage

43V ac max

ON-State Current

5.0mA min

ON-State Voltage

65V ac minimum, 132V ac maximum

Operational Temperature

-20 to +55oC (-4 to +131oF)

Pointbus Output Current

1A max @ 5V dc output

Power Consumption

8.2W maximum @ 24V dc

Power Dissipation

2.0W maximum @ 24V dc

Relative Humidity

5 to 95% noncondensing

Shock Operating

30g peak acceleration, 11(±1)ms pulse width

Storage Temperature

-40 to 85oC (-40 to 185oF)

Supply Current

10A max

Supply Voltage

120V ac nominal

Terminal Base Screw Torque

7 pound-inches (0.6 Nm)

Vibration

Tested 5g @ 10-500Hz per IEC 68-2-6

Voltage Range

65-132V ac

Datasheet

pdf file

allen bradley=1734D-IA16S=datashee-1755931110t.pdf

584 KiB

Extracted Text

Installation Instructions POINTBlock ac 16 Input Module (Cat. No. 1734D-IA16 and -IA16S) I/O Status Indicators DeviceNet Connector Remote Termination Blocks DeviceNet Node Setting Switches (1s and 10s) This 1734D input module is a DIN-rail mounted device with an integrated DeviceNet communication interface, 16 ac inputs, removable terminations, and a PointBus expansion port. The expansion port allows you to add up to 12 additional POINT I/O modules. The module includes a non-isolated DeviceNet communication interface. The 24V dc from the DeviceNet connection powers a non-isolated dc/dc converter that generates +5V dc which powers the POINTBlock electronics and connects to the PointBus port to power the expansion I/O electronics. The 1734D-IA16 uses cage-clamp terminations, and the 1734D-IA16S uses spring-clamp terminations. POINTBlock and POINT I/O are trademarks of Rockwell Automation1 Publication 1734D-IN001A-EN-P - May 2001 Module Status Network Status Inputs 0 4 8 12 1 5 9 13 0-9 2 6 10 14 10-63 3 7 11 15 2 POINTBlock ac 16 Input Module Simplified Schematic of POINTBlock En 24 CH PointBus Expansion Port CL CH 5V (allows expansion of up to DeviceNet GND SH 12 POINT I/O modules) Connector 24V CL to 5V RT Microprocessor Field Bus Connector I/O Circuits Power I/O Connections Connections 120V ac 41971 Whatever field power you supply is connected ATTENTION to the internal field-power bus. For example, if 120V ac is applied to the power connections, there will be 120V ac applied to the modules through the internal field-power bus. ! POINT I/O modules to the right of this module will have this internal power bus voltage applied, unless you use a 1734-FPD to interrupt and change the field power-bus voltage. Publication 1734D-IN001A-EN-P - May 2001 POINTBlock ac 16 Input Module 3 POINTBlock is designed to be grounded through ATTENTION the DIN rail to chassis ground. To assure proper grounding of POINTBlock and POINT I/O adapters and terminal bases to chassis ground, the recommended DIN rail material is zinc-plated, ! yellow-chromated steel. Mount POINTBlock, POINT I/O adapters and terminal bases only to zinc-plated, yellow-chromated steel. Installing the POINTBlock 16 Input Module To install the 16 Input module on the DIN rail, proceed as follows: 1. Position the block module vertically above the DIN rail. 2. Press down firmly to install the module on the DIN rail. (The locking mechanism will lock the module to the DIN rail.) Do not discard the end cap. Use this end cap to ATTENTION cover the exposed interconnections on the last mounting base/block module on the DIN rail. Failure to do so could result in equipment damage or injury from electric shock. ! If installing a replacement POINTBlock module to an existing system: 1. To remove the block module from the DIN rail, pull up on the RTB removal handles to remove the terminal blocks. 2. Use a small bladed screwdriver to rotate the orange DIN rail locking screw to a vertical position. This releases the locking mechanism. 3. Lift straight up to remove. 4. Position the replacement block module vertically above the DIN rail. Publication 1734D-IN001A-EN-P - May 2001 4 POINTBlock ac 16 Input Module 5. Slide the block module down allowing the interlocking side pieces to engage the adjacent module/adapter. 6. Press firmly to seat the block module on the DIN rail. The module locking mechanism will snap into place. Setting the Node Address Module Status Network Status I/O status R 1’s Node Address Rotary Switch 10’s Node Address Rotary Switch To set the node address, set the combination of 1’s and 10’s to correspond to the required address. (For example, for 61, set the 10’s switch to 6 and the 1’s switch to 1.) Publication 1734D-IN001A-EN-P - May 2001 POINTBlock ac 16 Input Module 5 Wiring the 16 ac Input Module Field Power Inputs 01 01 01 01 01 NC NC 0 1 4 5 8 9 12 13 23 23 23 23 23 120V ac Power NC NC 2 3 6 7 10 11 14 15 45 45 45 45 45 L2 in L2 in L2 L2 L2 L2 L2 L2 L2 L2 V ac 67 67 67 67 67 L1in L1in L1 L1 L1 L1 L1 L1 L1 L1 RTB 0 RTB 1 RTB 2 RTB 3 RTB 4 This supply will be connected to the internal power bus. NC = No Connection Chas Gnd = Chassis Ground 42064IB L2/N = AC Return/Neutral L1 = AC Power Input Wiring RTB 1 01 In 0 In 1 2 3 In 2 In 3 Prox Prox 4 5 L2 L2 6 7 L1 L1 41967ac L1 = 120V ac Repeat for RTB 2, 3 and 4 L2 = Return Note: When connecting more than 1 wire in a termination point, make sure that both wires are the same gauge and type. Publication 1734D-IN001A-EN-P - May 2001 6 POINTBlock ac 16 Input Module Channel Input Terminal Return Voltage Remote Termination Block 0 Field Power Block No connections to terminals 0, 1, 2, 3 and 4 Vin (L1) 6 and/or 7 Return (L2/N) 4 and/or 5 Remote Termination Block 1 00 6 11 7 22 6 33 7 Remote Termination Block 2 40 6 51 7 62 6 73 7 Remote Termination Block 3 80 6 91 7 10 2 6 11 3 7 Remote Termination Block 4 12 0 6 13 1 7 14 2 6 15 3 7 120V ac is supplied through the internal power bus. Note: When connecting more than 1 wire in a termination point, make sure that both wires are the same gauge and type. Publication 1734D-IN001A-EN-P - May 2001 POINTBlock ac 16 Input Module 7 DeviceNet Connector Wiring Red +V DeviceNet White CAN - High connection Bare Shield CAN - Low Blue 42132 -V Black Communicating with Your Module I/O messages are sent to (consumed) and received from (produced) the POINTBlock I/O modules. These messages are mapped into the processor’s memory. This POINTBlock I/O input module produces 2 bytes of input data (scanner Rx). It does not consume I/O data (scanner Tx). Default Data for the 1734D-IA16 15 14 13 12 11 10 987 65432 10 Produces I15 I14 I13 I12 I11 I10 I9 I8 I7 I6 I5 I4 I3 I2 I1 I0 (Rx) Consumes No consumed data (Tx) Where: I0 = channel 0, I1 = channel 1; 0 = off, 1 = on Publication 1734D-IN001A-EN-P - May 2001 8 POINTBlock ac 16 Input Module Safety Approvals Approbation d’utilisation dans des C-UL and UL Hazardous Location Approval environnements dangereux par la C-UL and UL C-UL and UL certifies products for general use as well as for use in La C-UL and UL certifie des produits pour une utilisation générale aussi hazardous locations. Actual C-UL and UL certification is indicated bien que pour une utilisation en environnements dangereux. La by the product label as shown below, and not by statements in any certification C-UL and UL en vigueur est indiquée par l'étiquette produit user documentation. et non par des indications dans la documentation utilisateur. Exemple d'étiquette de Example of the C-UL CL I, DIV 2 certification d'un CL I, DIV 2 and UL certification produit par la C-UL and GP A,B,C,D product label: GP A,B,C,D UL : CUS CUS TEMP TEMP LISTED LISTED To comply with C-UL and UL certification for use in hazardous locations, EPour satisfaire à la certification C-UL and UL en environnements the following information becomes a part of the product literature for dangereux, les informations suivantes font partie intégrante de la this C-UL and UL-certified industrial constrol product. documentation des produits de commande industrielle certifiés. • This equipment is suitable for use in Class I, Division 2, Groups • Cet équipement ne convient qu’à une utilisation dans A, B, C, D, or non-hazardous locations only. des environnements de Classe I, Division 2, • The products having the appropriate C-UL and UL markings Groupes A, B, C, D ou non dangereux. (that is, Class I, Division 2, Groups A, B, C, D) are certified for • Les produits portant le marquage C-UL and UL approprié use in other equipment where the suitability of combination (c'est-à-dire Classe I, Division 2, Groupes A, B, C, D) sont certifiés (that is, application or use) is determined by the C-UL and UL or pour une utilisation avec d'autres équipements, les combinaisons the local inspection office having jurisdiction d’applications et d’utilisation étant déterminées par la C-UL and • Peripheral equipment must be suitable for the location in UL ou le bureau local d'inspection. which it is used. • L'équipement périphérique doit convenir à l'emplacement d'utilisation. Important: Due to the modular nature of a programmable control Important: De par la nature modulaire des systèmes de commande system, the product with the highest temperature rating programmables, le produit ayant le code de température le plus determines the overall temperature code rating of a élevé détermine le code de température global du système programmable control system in a Class I, Division 2, dans un environnement de Classe I, Division 2. Le code de location. The temperature code rating is marked on the température est indiqué sur l'étiquette produit. product label as shown. Temperature code rating: Code de température : CL I, DIV 2 CL I, DIV 2 GP A,B,C,D GP A,B,C,D TEMP TEMP CUS CUS Look for temperature code rating here Le code de température est indiqué ici. LISTED LISTED The following warnings apply to products having C-UL and UL certification Les avertissements suivants s'appliquent aux produits ayant la certification for use in hazardous locations. C-UL and UL pour une utilisation dans des environnements dangereux. WARNING: Explosion Hazard AVERTISSEMENT : Risque d'explosion • Substitution of components may impair suitability for Class I, • La substitution de composants peut rendre ce matériel inadapté à Division 2. une utilisation en environnement de • Do not replace components unless power has been switched Classe I, Division 2. off or the area is known to be non-hazardous. • Couper le courant ou s'assurer que l’environnement est classé non • Do not disconnect equipment unless power has been switched dangereux avant de remplacer des composants. off or the area is known to be non-hazardous. • Couper le courant ou s’assurer que l’environnement est classé non • Do not disconnect connectors unless power has been switched dangereux avant de débrancher l'équipement. off or the area is known to be non-hazardous. Secure any • Couper le courant ou s'assurer que l’environnement est classé non user-supplied connectors that mate to external circuits on this dangereux avant de débrancher les connecteurs. Fixer tous les equipment by using screws, sliding latches, threaded connecteurs fournis par l'utilisateur pour se brancher aux circuits connectors, or other means such that any connection can externes de cet appareil à l 'aide de vis, loquets coulissants, withstand a 15 Newton (3.4 lb.) separating force applied for a connecteurs filetés ou autres, de sorte que les connexions résistent minimum of one minute. à une force de séparation de 15 Newtons (1,5 kg - 3,4 lb.) appliquée • Batteries must only be changed in an area known to be pendant au moins une minute. non-hazardous. • S'assurer que l'environnement est classé non dangereux avant de changer les piles. C-UL and UL logo is a registered trademark of the Underwriters Le sigle C-UL and UL est une marque déposée de la Underwriters Laboratories. Laboratories. Publication 1734D-IN001A-EN-P - May 2001 POINTBlock ac 16 Input Module 9 Specifications Specifications - 1734D-IA16, -IA16S Input Specifications - IEC1+ 120V ac Compliant Number of Channels 16 input channels ON-State Voltage 65V ac minimum, 132V ac maximum ON-State Current 5.0mA min OFF-State Voltage 43V ac max OFF-State Current 2.5mA max Nominal Input Impedance 17.0kΩ Input Filter Time OFF to ON 20.0ms hardware + (0 - 65ms selectable) ON to OFF 20.0ms hardware + (0 - 65ms selectable) External AC Power Supply 120V ac, 60Hz nominal Voltage External AC Power Supply 85-132V ac, 47-63Hz Voltage Range General Specifications Pointbus Output Current 1A max @ 5V dc output DeviceNet Current 95mA maximum for POINTBlock 350mA for maximum with expansion of 12 POINT I/O modules Number of POINT I/O 12 maximum added at expansion port Expansion Modules Isolation Voltage 2104V dc for 1s between user power and DeviceNet Indicators 1 red/ green module status indicator 1 red/green network status indicator 16 yellow I/O status indicators Power Dissipation 2.0W maximum @ 24V dc Power Consumption 8.2W maximum @ 24V dc Field Power Bus Supply Voltage 120V ac nominal Voltage Range 65-132V ac Supply Current 10A max Dimensions Inches 3.00H x 2.36W x 5.25L (Millimeters) (76.2 Hx 60.0W x 133.4L) Publication 1734D-IN001A-EN-P - May 2001 10 POINTBlock ac 16 Input Module Environmental Conditions o o Operational Temperature -20 to +55 C (-4 to +131 F) o o Storage Temperature -40 to 85 C (-40 to 185 F) Relative Humidity 5 to 95% noncondensing Shock Operating 30g peak acceleration, 11(±1)ms pulse width Non-operating 50g peak acceleration, 11(±1)ms pulse width Vibration Tested 5g @ 10-500Hz per IEC 68-2-6 2 2 Conductors Wire Size 14 AWG (2.5mm ) - 22 AWG (0.25mm ) solid or stranded copper rated @ 75°C or greater 3/64 inch (1.2mm) insulation max 1 Category 2 Terminal Base Screw 7 pound-inches (0.6 Nm) Torque Field Wiring Terminations DeviceNet 1 - Black Wire -V 2 - Blue Wire CAN Low 3 - Bare Wire Drain 4 - White Wire CAN High 5 - Red Wire +V Field Power Supply 0 - No Connection1 - No Connection 2 - No Connection3 - No Connection 4 - AC return 5 - AC return 6 - AC power 7 - AC power Mass 13.88 oz/393.50 grams Agency Certification • C-UL Listed (when product is marked) • C-UL Class I, Division 2 Groups A, B, C and D certified • UL listed • UL Class I, Division 2 Groups A, B, C and D certified • CE marked for all applicable directives • C-Tick marked for all applicable acts 1 Use this conductor category information for planning conductor routing. Refer to publication 1770-4.1, “Industrial Automation Wiring and Grounding Guidelines.” Publication 1734D-IN001A-EN-P - May 2001 POINTBlock ac 16 Input Module 11 Publication 1734D-IN001A-EN-P - May 2001 Publication 1734D-IN001A-EN-P - May 2001 PN 957464-53 © 2001 Rockwell International Corporation. Printed in USA

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 1734D-IA16S?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Rockwell Automation 1734-232ASC Serial I/O Modules- Inputs/Outputs 1 Serial Interface channel, Point...

product

Rockwell Automation 1734-485ASC Serial I/O Modules- Inputs/Outputs 1 Serial Interface channel, Point...

product

Allen Bradley 1734-ADN I/O Adapter Module - 24V DC DeviceNet Adapter

product

Allen Bradley 1734-ADNX Adapter Module - DeviceNet I/O Adapter with Expansion Port, 63 POINT I/O mod...

product

Allen Bradley 1734d-IA16 PointBlock I/O Module - 120 VAC, 16 Inputs, DNET communication interface

product

Allen Bradley 1734D-IA8XOW8 PointBlock I/O Module - 120 VAC 8 Inputs 8 Relay Outputs, DNET Communica...