Part Number | PM65-12A |
---|---|
Manufacturer | XP POWER |
Category | Power Supply Board |
Price | Request Quote |
Lead Time | Request Quote |
XP Power PM65-12A Power Supply - 65W AC/DC Single Output Medical Open Frame
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a PM65-12A? We can help you find it at a competitive price!
Derating | Derate from 100% at +50°C linearly to 50% at +70°C |
---|---|
Efficiency | 70% minimum on single output models with Vo >12V, 65% minimum on the others. |
Hold-up time | 10 msec minimum at 110VAC |
Input Current | 1.60A(rms)for 115VAC | 1.00A(rms)for 230VAC |
Input Frequency | 47 to 63 Hz |
Input Voltage | 85 to 264 VAC |
Inrush Current | 15 amps @ 115VAC, or 30 amps @ 230VAC, at 25°C cold start |
LEAKAGE CURRENT | 90uA max. @ 115VAC, 60Hz | 150uA max. @ 230VAC, 50Hz |
Line Regulation | ±0.5% maximum at full load |
MTBF | 400,000 hours minimum at full load at 25°C ambient , calculated per MIL-HDBK-217F |
Operating Temperature | 0°C to +70°C |
Output voltage/current | See rating chart |
Overcurrent protection | All outputs protected to short circuit conditions |
Overvoltage Protection | Provided on output #1 only; set at 112 - 132% of its nominal output voltage |
Relative humidity | 5% to 95% non-condensing |
Ripple and Noise | 1% peak to peak maximum |
Storage Temperature | -40°C to +85°C |
Switching Frequency | 32KHz ±5KHz |
Temperature Coefficient | All outputs ±0.04%/°C maximum |
Total output power | 65 watts maximum |
Transient Response | Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500us after a 25% step load change |
Withstand voltage | 4000VAC from input to output | 1500VAC from input to ground | 500VAC from output to ground |
Download "XP Power=PM65Series=ds1-1622818470.pdf" (486 KiB)
PROTEK 50-65 WATT MEDICAL SWITCHING POWER SUPPLIES DESCRIPTION PM65 SERIES (LVD) The PM65 series of compact, open PCB constructed, RoHS AC-DC switching power supplies are capable of delivering 50 to 65 watts of continuous power. They are ideally suited for use in medical equipment not for life support and operate at 85 to 264VAC input voltage without the need of voltage selection. All models meet the safety requirements of UL, CSA and IEC. FEATURES ‧ Low safety ground leakage current ‧ Meet EN 55011 and FCC Class B ‧ Small size, light weight ‧ 100% burn-in ‧ Wide input range 85 to 264VAC Safety Standard Approvals: ‧ Input surge current protection ‧ Overvoltage protection UL 2601-1 ‧ Overcurrent protection File No. E178020 ‧ Compliant with RoHS requirements CSA C22.2 No. 601.1 File No. LR93632 INPUT SPECIFICATIONS Input voltage: 85 to 264VAC TÜV EN60601-1 Input frequency: 47 to 63Hz Certificate No. R9172041 1.60A(rms)for 115VAC Input current: 1.00A(rms)for 230VAC Earth leakage current: 90uA max. @ 115VAC, 60Hz 150uA max. @ 230VAC, 50Hz GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS Switching frequency: 32KHz ±5KHz 70﹪ minimum on single output models with Efficiency: See rating chart Output voltage/current: Vo ≧12V, 65% minimum on the others. Total output power: 65 watts maximum 10 msec minimum at 110VAC Hold-up time: Ripple and noise: 1﹪peak to peak maximum Line regulation: ±0.5﹪ maximum at full load Overvoltage protection: Provided on output #1 only; Inrush current: 15 amps @ 115VAC or 30 amps @ 230VAC, at 25℃ cold start set at 112-132﹪of its Withstand voltage: nominaloutput voltage 4000VAC from input to output 1500VAC from input to ground Overcurrent protection: All outputs protected to 500VAC from output to ground short circuit conditions 400,000 hours minimum at full load at 25℃ MTBF: Temperature coefficient: All outputs ±0.04﹪/℃ ambient , calculated per MIL-HDBK-217F maximum EMC Performance (EN60601-1-2: 2001) Maximum excursion of 4﹪ or Transient response: Class B conducted, Class B radiated EN55011: better on all models, recovering FCC: Class B conducted, Class B radiated to 1﹪of final value within 500us Class B conducted, Class B radiated VCCI: after a 25﹪step load change EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, ± 8KV air and ± 6KV contact EN61000-4-3: Radiated immunity, 3V/m, for 80~2500MHz ENVIRONMENTAL SPECIFICATIONS EN61000-4-4: Fast transient/burst, ± 2KV EN61000-4-5: Surge, ± 1KV diff., ± 2KV com. Operating temperature: 0℃℃ to +70 EN61000-4-6: Conducted immunity, 3Vrms Storage temperature: -40℃℃ to +85 EN61000-4-8: Magnetic field immunity, 3A/m Relative humidity: 5﹪to 95﹪non-condensing Voltage dips, 30% reduction for 500ms, 60% EN61000-4-11: Derating: Derate from 100﹪at +50℃ reduction for 100ms and >95% reduction for linearly to 50% at +70℃ 10ms 2-9 UNIVERSAL INPUT PM65 MEDICAL SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Maximum (1)(2) Output #1 Output #2 Output #3 Output #4 Output MODEL Vnom. Imin. Imax. Tol. Vnom. Imin. Imax. Tol. Vnom. Imin. Imax. Tol. Vnom. Imin. Imax. Tol. Power PM65-10A 5V 0A 10A 2% (N/A) (N/A) (N/A) 50W PM65-12A 12V 0A 5.5A 1% (N/A) (N/A) (N/A) 65W PM65-13A 15V 0A 4.5A 1% (N/A) (N/A) (N/A) 65W PM65-14A 24V 0A 3.0A 1% (N/A) (N/A) (N/A) 65W PM65-16A 30V 0A 2.5A 1% (N/A) (N/A) (N/A) 65W PM65-17A 36V 0A 2.2A 1% (N/A) (N/A) (N/A) 65W PM65-23A +5V 1A 6.0A 3%+12V 0.5A 3.0A 5% (N/A) (N/A) 65W PM65-24A +5V 1A 6.0A 3%+15V 0.4A 3.0A 5% (N/A) (N/A) 65W PM65-25A +5V 1A 6.0A 3%+24V 0.3A 2.0A 5% (N/A) (N/A) 65W PM65-30A +5V 1A 6.0A 3%+12V 0.5A 3.0A 5% -5V 0.1A 0.5A10% (N/A) 65W PM65-31A +5V 1A 6.0A 3%+12V 0.5A 3.0A 5% -12V 0.1A 0.5A10% (N/A) 65W PM65-32A +5V 1A 6.0A 3%+15V 0.4A 3.0A 5% -15V 0.1A 0.5A10% (N/A) 65W PM65-33A +5V 1A 6.0A 3%+15V 0.4A 3.0A 5% -12V 0.1A 0.5A10% (N/A) 65W PM65-39A +5V 1A 6.0A 3%+24V 0.3A 2.0A 5% -12V 0.1A 0.5A10% (N/A) 65W PM65-40A +5V 1A 6.0A 3% +12V 0.5A 3.0A 5% -12V 0.1A 0.5A 10% -5V 0.1A 0.5A 10% 65W NOTES: 1. All multiple output models may be operated at no-load without damage. At no-load, output voltage tolerance increases to 10% 2. Safety agency approvals are for the above listed models in PCB format. To order a model with a metallic L-bracket or box, change suffix “A” to “B” for L-bracket format or to “C” for enclosed format (mechanical details shown in page 7-2), e.g. PM65-25C. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3081 and Molex 2878 series crimp terminal. 5. Weight: 400 grams (PCB format) 6. The “*” marked mounting hole is for system grounding through a metallic stand-off to the system chassis. PIN CHART PIN 1 2 3 4 5 6 7 8 MODEL PM65-10A PM65-12A OUTPUT OUTPUT OUTPUT OUTPUT PM65-13A PM65-14A RETURN RETURN RETURN RETURN #1 #1 #1 #1 PM65-16A PM65-17A PM65-23A PM65-24A OUTPUT OUTPUT COMMON COMMON OUTPUT OUTPUT N.C. N.C. PM65-25A #1 #1 RETURN RETURN #2 #2 PM65-30A PM65-31A OUTPUT OUTPUT COMMON COMMON OUTPUT OUTPUT OUTPUT PM65-32A PM65-33A N.C. #1 #1 RETURN RETURN #2 #2 #3 PM65-39A OUTPUT OUTPUT COMMON COMMON OUTPUT OUTPUT OUTPUT OUTPUT PM65-40A #1 #1 RETURN RETURN #2 #2 #3 #4 2-10
Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.
GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.
All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.