Industrial Trading chervon right Manufacturers chervon right T chervon right TDK-LAMBDA chervon right Alpha 1000
About product Specifications Features Datasheet FAQ

TDK-LAMBDA Alpha 1000

Image of TDK-LAMBDA Alpha 1000

Description

Lambda Alpha 1000 Power Supply-1000W Multiple Output Modular Power Supply

Part Number

Alpha 1000

Price

Request Quote

Manufacturer

TDK-LAMBDA

Lead Time

Request Quote

Category

Power Supply

Specifications

AC Input Volt. range & Freq

85-264VAC, 47-63Hz

Altitude

0 - 10,000 feet Operating (3,300 metres)

Conducted EMI

EN55022 level A

Cooling

Internal fan provides forced-air cooling. Airflow intake on I/P end, exhaust on O/P end of unit.

DC Input Voltage Range

120 - 360VDC (800W maximum output to 45C)

Efficiency

75% typical (configuration and input dependent)

Hold Up Time

Output voltages will remain within specified regulation for a minimum of 15mS after;loss of applied power on the AC input at full rated output

Humidity

RH 5% - 95% Non-condensing

Input Current

16A maximum

Inrush Current

Less than 50A

Isolation

Input - Output 3000VAC, Input - Ground 1500VAC, Output - Ground 500VDC

Leakage Current

1.1mA @ 260VAC, 50Hz (see input filter options in detailed product datasheet)

Module Slots

7

No Load Operation

No preload is required on any output module.

Operating Temperature

20°C to +50°C full load, derate each output at 3.3% /°C from 50°C to 65°C.

Options (see option codes)

AC Fail, Global Inhibit, Module Inhibit, 5V@50mA aux., Parallel, Low Leakage.

Output Line Regulation

0.5% maximum.

Output Load Regulation

0.2% maximum.

Output Power

800W@85VAC (50°C max); 1000W@100VAC (50°C max); 1000W@90VAC (45°C max);

Power Factor Correction

Compliant to EN61000-3-2 ( > 0.95 typical, reduced PFC > 255VAC)

Remote Sense

Available on single output modules only, refer to the module table.

Ripple & Noise

2% pk-pk

Safety Agency Approvals

UL60950-1, EN/IEC60950-1, UL60601-1, EN/IEC60601-1, IEC61010-1, EN61010-1, CE Mark

Shock

3,000 bumps, 10G, 16ms half-sine pulses.

Size (WxHxD)

7" x 2.5" x 11"

Storage Temperature

40°C to +85°C

Switching Frequency

100kHz on PFC, 200kHz on forward converter.

Temperature Coefficient

0.02% per °C

Thermal Protection

Converter protected against over-temperature conditions. Recycle I/P power to restore output.

Vibration

1.5G, 10 - 200Hz

Features

Datasheet

pdf file

alpha1000.pdf

83 KiB

Extracted Text

Alpha 1000 1000W Multiple Output Modular Power Supply ‹ Customized Power Supplies ‹ Universal AC Input ‹ Power factor Corrected ‹ Capable of up to 14 fully regulated and independent outputs ‹ Output Voltages from 1.8V - 48V ‹ Low Leakage Options ‹ Input Transient Protection ‹ Compact Package ‹ International Safety Agency Approvals Alpha Features and Benefits Feature Benefit ‹ PFC compliant to EN61000-3-2 ‹ Supports global use ‹ Fast-on Tab Connections ‹ Quick installation ‹ No Minimum Load ‹ Eliminates the need for external components ‹ Wide Range Output Modules ‹ Capable of providing non-standard voltages, eliminates customs Specifications MODELS ITEMS AC Input Volt. range & Freq. - 85-264VAC, 47-63Hz DC Input Voltage Range - 120 - 360VDC (800W maximum output to 45C) Input Current A 16A maximum Inrush Current A Less than 50A Leakage Current - 1.1mA @ 260VAC, 50Hz (see input filter options in detailed product datasheet) Efficiency % 75% typical (configuration and input dependent) Power Factor Correction - Compliant to EN61000-3-2 ( > 0.95 typical, reduced PFC > 255VAC) Conducted EMI - EN55022 level A Output Power W 800W@85VAC (50°C max); 1000W@100VAC (50°C max); 1000W@90VAC (45°C max); 1000W for 30 seconds maximum @ 85VAC followed by 800W for 60 seconds minimum. Output Load Regulation - 0.2% maximum. Output Line Regulation - 0.5% maximum. Ripple & Noise - 2% pk-pk No Load Operation - No preload is required on any output module. Hold Up Time ms Output voltages will remain within specified regulation for a minimum of 15mS after loss of applied power on the AC input at full rated output Remote Sense - Available on single output modules only, refer to the module table. Options (see option codes) - AC Fail, Global Inhibit, Module Inhibit, 5V@50mA aux., Parallel, Low Leakage. Operating Temperature °C -20°C to +50°C full load, derate each output at 3.3% /°C from 50°C to 65°C. Thermal Protection - Converter protected against over-temperature conditions. Recycle I/P power to restore output. Storage Temperature °C -40°C to +85°C Temperature Coefficient - 0.02% per °C Humidity % RH 5% - 95% Non-condensing Altitude - 0 - 10,000 feet Operating (3,300 metres) Cooling - Internal fan provides forced-air cooling. Airflow intake on I/P end, exhaust on O/P end of unit. Isolation - Input - Output 3000VAC, Input - Ground 1500VAC, Output - Ground 500VDC Switching Frequency - 100kHz on PFC, 200kHz on forward converter. Vibration - 1.5G, 10 - 200Hz Shock - 3,000 bumps, 10G, 16ms half-sine pulses. Safety Agency Approvals - UL60950-1, EN/IEC60950-1, UL60601-1, EN/IEC60601-1, IEC61010-1, EN61010-1, CE Mark Module Slots - 7 Size (WxHxD) in. 7" x 2.5" x 11" Warranty - Three Years Notes: (Consult datasheet for additional specifications) 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 Alpha 1000 1 Case Codes 3 Option Codes If required the following options may be added to the configuration by placing the Choose the converter which best fits your total power needs: code after the module. (i.e. Inhibiting a 5V @ 25A = 5B + Inhibit code = “5BIN”) C Co od de e W Wa atttta ag ge e M Ma ax x S Sllo otts s S Siiz ze e ((H H x x W W x x L L)) IIn np pu utt V Vo olltta ag ge e Code Description Available On CA1000 1000* 7 2.5" x 7" x 11" 85 - 265VAC 2 MF Mains Fail All modules except * Note: CA1000 derates to 800W for 85–100VAC input with a peak of 1000W for This option provides an AC fail signal, power supply Dual output (E, H, P) 30 seconds maximum. inhibit, and 5V@50mA auxiliary supply. This is only (TTL compatible reference placed in the first module slot. to 0 volts of Aux. Supply) 2 Output Module Codes PP Parallel for Power Modules: A, B, C, D, From the table below match the available modules to your voltage This option allows 2 adjacent modules to be paralleled F, G, M, N, Q, R together for increased output power. Bus bars provided. and current requirements. PA Parallel for Redundancy Modules: A, B, C, D, Format = Desired Voltage + Module Code Letter This option allows modules to be connected for N+1 F, G, M, N, Q, R, S (5V@20A=“5B” or (5.1V@5A) & 12.7@2A=“5.1/12.7E”) A DC good signal is also offered (electrically redundancy. similar to AC fail.) No bus bars provided. 3 1 Code V1 nom Amps V2 nom Amps V1 adjust V2 adjust Slot(s) 3 IN Inhibit Modules A, B, C, D, L 2.0 25 - - 1.8 - 2.7 - 1 Module inhibit and DC good signal. F, G, J, M, N, Q, R T 2.0 60 - - 1.8 - 2.7 - 2 (TTL compatible referenced to (-V) of the module) Q 3.3 25 - - 2.7 - 3.9 - 1 Low Leakage Options All converters R 3.3 60 - - 2.7 - 3.9 - 2 Max. Leakage Current Conducted RFI B 5 25 - - 4.5 - 5.5 - 1 LL 212 µA Curve A A 5 60 - - 4.5 - 5.5 - 2 RL 100 µA Above Curve A S 5 85 - - 2.5 - 5.7 - 2 TL 50 µA Above Curve A M 12 8 - - 5.0 - 15.0 - 1 3 C 12 16 - - 5.0 - 15.0 - 1 Notes: 1) Only one option per module may be used. F 12 33 - - 10.0- 15.0 - 2 2) Mains Fail: AC Fail “AC On” = ≤ 0.8V, 50mA max. N 24 5 - - 18.0 - 28.0 - 1 “AC Off” = open circuit, 50V abs max. D 24 8 - - 18.0 - 28.0 - 1 PS Inhibit “PS On” = ≥ 2.0V or open circuit. G 24 25 - - 18.0 - 28.0 - 2 “PS Off” = ≤ 0.8V @ 5mA. J 36 10 - - 36.0 - 48.0 - 2 (TTL compatible, Referenced to 0 volts of Aux. Supply.) J 48 7.5 - - 36.0 - 48.0 - 2 3) Inhibit: DC Good Electrically similar to AC fail module. 3 3 E 12 8 12 8 5.0 - 15.0 5.0 - 15.0 1 Inhibit Electrically similar to PS inhibit. 3 P 24 5 12 8 18.0 - 28.0 5.0 - 15.0 1 3 3 H 24 5 24 5 18.0 - 28.0 18.0 - 28.0 1 Outline Drawing Notes: 1) The total # of slots must not exceed 7 for CA1000. 2) The written order determines the slot position. (This may change upon 279.00 4.50 248.00 order placement.) 37.00 3) Module Deratings: C derates linearly to 12A from 12.1V–15V 25.00 E & P: 8A rating derates to 6A in slots 4 & 5. H derates from 5A to 4A in slots 4 & 5. 4.5MM MAXIMUM SCREW PENETRATION 8 OFF M4 PRIMARY FIXINGS 4) Remote Sensing: Dual output modules do not have remote sensing. Modules (A, B, Q, R, S) have 0.5V total line drop, 1V for all others. 5) Format for module code = desired voltage + module code letter. MAINS INPUT Refer to the following examples: (26V @ 24A = “26G”) or ( 5.1V @ 8A & 12V @ 8A = “5.1/12E”). 216.00 6.00 Sample Configurations Output 1 Output 2 Output 3 Output 4 Output 5 VA V A V A V A V A CA1000-24G 24 16.5 - - - - - - - - CA1000-5APP-5APP* 5 120 - - - - - - - - CA1000-5A-12.7C 5 60 12.7 16 - - - - - - CA1000-24G-5/12E 24 25 5 8 12 8 - - - - CA1000-5A-24G-12C-12C 5 60 24 25 12 16 12 16 - - CA1000-5BMF-24D-6/12E 5 25 24 8 6 8 12 8 - - CA1000-5B-5CIN-12C-12/12E 5 25 5 16 12 16 12 8 12 8 63.00 CA1000-5S-12F-12C-5/24P 5 85 12 33 12 16 5 8 24 5 2 OFF M4 SECONDARY FIXINGS Note: Total output power must not exceed 1000W converter limits. 4.5MM MAXIMUM SCREW PENETRATION * Modules in parallel. THESE 2 FIXINGS MUST ONLY TO BE USED IN CONJUNCTION WITH THE PRIMARY FIXINGS 15.00 110.00 GENERAL TOLERANCE Å} 0.5MM Other Lambda Modular Products SC150 150W up to 4 outputs Sirius 250W to 350W up to 6 outputs NV350 350W up to 6 outputs For Additional Information, please visit Vega 450W to 900W up to 10 outputs www.lambdapower.com/products/alpha-series.htm Alpha1500 1500W up to 16 outputs 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 Revision A3: Mar 2005 4 S Siin ng glle e O Ou uttp pu utts s D Du ua all 175.50 50.00 115.50 30.00 12.00 34.00 7 OUTPUT MODULE SLOTS

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the Alpha 1000?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

LAMBDA CA1000 H17096 frame modular AC/DC power supply

product

Lambda DLP100241/E Power Supply, DIN Rail Mount; 170 to 265/85 to 132 VAC; 47 to 63 Hz

product

Lambda DLP100-24-1/E Power Supply with 24V Output

product

Lambda DLP180241/E Power Supply, DIN Rail, 24V Output

product

Lambda DLP180-24-1/E Power Supply with 25V Output

product

Lambda DLP240-24-1. Power Supply with Input | 100-240VAC | 3.5A Maximum | Output: 24VDC/10A