Industrial Trading chervon right Manufacturers chervon right S chervon right SL POWER chervon right GPC80B
About product Specifications Features Datasheet FAQ

SL POWER GPC80B

Image of SL POWER GPC80B

Description

SL Power / Condor Power GPC80B Power Supply. Open Frame | Chassis | 80 W | +-5V, +-12V AT Output

Part Number

GPC80B

Price

Request Quote

Manufacturer

SL POWER

Lead Time

Request Quote

Category

Power Supply

Specifications

AC Input

85-264 Vac, 47-63 Hz single phase.

Commercial Leakage Current

0.7 mA 254 Vac @ 60 Hz input.

Commercial Safety

Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial; CSA #LR46516 all. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault conditions.

Efficiency

70% at full rated load, nominal input voltage, depending on model and load distribution.

EMI/EMC Compliance

All models include built-in EMI filtering to meet the following emissions requirements:EMI SPECIFICATIONS COMPLIANCE LEVEL, Conducted Emissions GPC80 EN55022 Class B; FCC Class B, Conducted Emissions GPM80 EN55011Class B; FCC Class B, Static Discharge EN61000-4-2, 6 kV contact, 8 kV air, RF Field Susceptibility EN61000-4-3, 3 V/meter, Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz, Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Line Frequency Harmonics EN61000-3-2 Class A

Environmental

Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications on next page.

Hold-up time

20 ms minimum from loss of ac input at full load, nominal line (115 Vac).

Input Current

Maximum input current at 120 Vac, 60 Hz with full rated output load: 2.3 A

Input Protection

Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.

Inrush Current

Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A. Temperature Coefficient 0.03%/°C typical on all outputs.

Medical Commercial Safety

Approved to UL2601-1, CSA-C22.2 No. 601.1 Level 3 and IEC601.1. UL file E116994; CSA #LR46516. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions.

Medical Leakage Current

35 µA 254 Vac @ 60 Hz input.

Output noise

0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Output Power

80 W continuous, 110 W with air flow. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.

Overload Protection

Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. Factory set to begin power limiting at 120 W. See output ratings chart for additional notes or conditions.

Overvoltage Protection

Main outputs: 124% ± 12% typical.

Power Fail (optional)

TTL- or CMOS-compatible output goes low (

Remote sense

Provided as a standard feature on single-output models.

Transient response

Main output—500 µs typical response time for return to within 0.5% of final value for a 50% load step change. ?i/?t

Voltage Adjustment

Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.

Features

Datasheet

pdf file

GPC80P.pdf

253 KiB

Extracted Text

GPC80 Commercial/GPM80 Medical 80 Watt Global Single and Multiple Output Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601.1 Complies with EN61000-3-2 Class A marked to LVD SPECIFICATIONS: Ac Input trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are avail- 85-264 Vac, 47-63 Hz single phase. able to the user through adjustment of built-in potentiom- eter (consult factory for assistance). For Power fail option, Input Current add -PF after model number. Maximum input current at 120 Vac, 60 Hz with full rated output load: 2.3 A Output Noise 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential Hold-Up Time mode. Measured with noise probe directly across output 20 ms minimum from loss of ac input at full load, nominal terminals of the power supply. line (115 Vac). Transient Response Output Power Main output—500 µs typical response time for return to 80 W continuous, 110 W with air flow. Peak ratings are for within 0.5% of final value for a 50% load step change. Δi/ 60 s maximum duration, 10% duty cycle. During peak Δt<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/ load condition, output regulation may exceed total shutdown overshoot less than 3%. regulation limits. Remote Sense Overload Protection Provided as a standard feature on single-output models. Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on Voltage Adjustment outputs 1 & 2; foldback type on outputs 3 & 4. Recovery Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. after fault is automatic. Factory set to begin power limiting at 120 W. See output ratings chart for additional notes or EMI/EMC Compliance conditions. All models include built-in EMI filtering to meet the following emissions requirements: Overvoltage Protection EMI SPECIFICATIONS COMPLIANCE LEVEL Main outputs: 124% ± 12% typical. Conducted Emissions GPC80 EN55022 Class B; FCC Class B Conducted Emissions GPM80 EN55011Class B; FCC Class B Efficiency Static Discharge EN61000-4-2, 6 kV contact, 8 kV air 70% at full rated load, nominal input voltage, depending RF Field Susceptibility EN61000-4-3, 3 V/meter on model and load distribution. Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Input Protection Line Frequency Harmonics EN61000-3-2 Class A Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit. Commercial Leakage Current 0.7 mA 254 Vac @ 60 Hz input. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac Commercial Safety under cold start conditions will not exceed 34 A. Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial; CSA Temperature Coefficient #LR46516 all. The output(s) are intended for safety 0.03%/°C typical on all outputs. earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault Environmental conditions. Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by Medical Leakage Current 2.5% per °C above 50°C. See Environmental and 35 µA 254 Vac @ 60 Hz input. Packaging Specifications on next page. Medical Commercial Safety Power Fail (optional) Approved to UL2601-1, CSA-C22.2 No. 601.1 Level 3 TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms and IEC601.1. UL file E116994; CSA #LR46516. The before output voltage drops more than 4% below nominal output(s) are intended for safety earthed Signal Output voltage upon loss of ac power. The signal is factory set to and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565  FAX 805-487-8911  www.condorpower.com 44 GPC80 Commercial/GPM80 Medical 80 Watt Single and Multiple Output Commercial Medical Output Output Output Total Model Model Output No. Output Minimum Maximum (B) Maximum (C) Output Peak Noise P-P Regulation (A) GPC80A GPM80A 1 +5 V 1.0 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% GPC80B GPM80B 1 + 5 V 1.0 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 -5 V 0 A 1 A 1.2 A 1.2 A 50 mV 3% GPC80C GPM80C 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% 4 +15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% GPC80D GPM80D 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0 A 2 A 3 A 4 A 240 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% GPC80E GPM80E 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0 A 2 A 3 A 4 A 240 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% 4 +15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% GPC80P GPM80P 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0.5 A 3.5 A 4.5 A 4.5 A 400 mV +10%/-5% (D) 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 2 A 2 A 2.5 A 120 mV 3% GPC80-5 GPM80-5 1V5A0A1A 6 2A 0 2V 2 5% 0 m 2 GPC80-12 GPM80-12 1V1A 2 0A6A .7 9A .2 9V .2 1% 20 m 2 GPC80-15 GPM80-15 1V1A 5 0A5A .3 7A .3 7V .3 1% 50 m 2 GPC80-24 GPM80-24 1V2A 4 0A3A .4 4A .6 4V .6 2% 40 m 2 GPC80-28 GPM80-28 1V2A 8 0A2A .9 3A .9 3V .9 2% 80 m 2 GPC80-48 GPM80-48 1V4A 8 0A1A .7 2A .3 2V .3 4% 80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Ratings for unrestricted natural convection cooling; output 1 & 2 combined load not to exceed 14A continuous; total power = 80W. C. Ratings with 26 cfm forced air cooling; output 1 & 2 combined load not to exceed 16A continuous; total power = 110W. D. To maintain these regulation conditions, the +5V current must be at least 1/4 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted within ±1% with at least a 1A load to maintain regulation on this input. E. For Power Fail option, add -PF after the model number. GPC80/GPM80 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 95% R 0 to 95% R before application of power. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Sg hock (B) 20 40 g pk pk orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. At ltitude-t 500 to 10,000 f -500 to 40,000 f C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929  805-486-4565  FAX 805-487-8911  www.condorpower.com 45

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the GPC80B?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SL Power / Condor Power CPQ400 Power Supply Assembly

product

SL Power/Condor Power F24-12-A+ Power Supply. Open Frame | 288 Watts | 24 VDC @ 12 A | 100-240 VAC

product

SL Power / Condor Power GLC110-12 Power Supply. Open Frame | Commercial | 110 W | 12V @ 6.3A Single ...

product

SL Power / Condor Power GLC110-212 Power Supply. Open Frame | Commercial | 110 W | 12V @ 6.3A, -12V ...

product

PWR SPLY SWITCHER 110W MULTI

product

SL Power / Condor Power GLM110-12 Power Supply. Open Frame | Medical | 110 W | 12 VDC @ 6.3A Single ...