Description

SL Power / Condor Power GPC200E Power Supply. Open Frame | 200 W | +-15V, 24V, 5V DC Quad Output

Part Number

GPC200E

Price

Request Quote

Manufacturer

SL POWER

Lead Time

Request Quote

Category

Power Supply

Features

Datasheet

pdf file

GPC200E.pdf

176 KiB

Extracted Text

GPC200 Commercial/GPM200 Medical 200 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 Multiple outputs marked to LVD Power Fail SPECIFICATIONS: TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms Ac Input before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip on 85-264 Vac, 47-63 Hz single phase. 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through Input Current adjustment of built-in potentiometer. Maximum input current at 120 Vac, 60 Hz with full rated output load: 5.5 A Output Noise Hold-Up Time 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. 20 ms minimum from loss of ac input at full load, nominal line Measured with noise probe directly across output terminals of (115 Vac). the power supply. Output Power Transient Response 150 W convection; 200 with 26 cfm air; 220 W peak. Peak ratings Main output—500 µs typical response time for return to within are for 60 s maximum duration, 10% duty cycle. During peak 0.5% of final value for a 50% load step change. Δi/Δt<0.2 A/µs. load condition, output regulation may exceed total regulation Maximum voltage deviation is 3.5%. Startup/shutdown overshoot limits. less than 3%. Overload Protection Remote Sense Fully protected against short circuit and output overload. Short Provided as a standard feature on main 5 V output. circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. Voltage Adjustment See output ratings chart for additional notes or conditions. Built-in potentiometer adjusts voltage ±5% on output 1 & 2. Overvoltage Protection EMI/EMC Compliance Main outputs: 124% ± 12% typical. All models include built-in EMI filtering to meet the following emissions requirements: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL Minimum 65% at full rated load, nominal input voltage, depending Conducted Emissions GPC200 EN55022 Class B; FCC Class B on model and load distribution. Conducted Emissions GPM200 EN55011 Class B; FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Input Protection RF Field Susceptibility EN61000-4-3, 3 V/meter Internal ac fuse provided. Designed to blow only if a catastrophic Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz failure occurs in the unit. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Inrush Current Commercial Leakage Current Inrush is limited by internal thermistors. Inrush at 240 Vac under 0.95 mA 254 Vac @ 60 Hz input (with no deviations). cold start conditions will not exceed 60 A. Commercial Safety Temperature Coefficient Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial; CSA #LR46516 all 0.03%/°C typical on all outputs. models. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV Thermal Shutdown under normal and single fault conditions. Provided as a standard feature. Designed to protect unit from prolonged overtemperature. Medical Leakage Current 60 µA 254 Vac @ 60 Hz input. Environmental Designed for 0 to 50°C operation at full rated output power; Medical Safety derate output current and total output power by 2.5% per °C Approved to UL2601-1, CSA-C22.2 No. 601 Level 3 and IEC601. above 50°C. See Environmental and Packaging Specifications UL file E116994; CSA #LR46516. The output(s) are intended for on next page. safety earthed Signal Output and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565  FAX 805-487-8911  www.condorpower.com 64 GPC200 Commercial/GPM200 Medical 200 Watt Multiple Output Commercial Medical Output Output Output Total Output No. Output Output Peak Noise P-P Model Model Minimum Maximum (B) Maximum (C) Regulation (A) GPC200A GPM200A 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +12 V 0 A 5 A 8 A 12 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3% 4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3% GPC200B GPM200B 1 + 5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +12 V 0 A 5 A 8 A 12 A 120 mV 2% 3 -5 V 0 A 1 A 1.2 A 1.5 A 50 mV 3% 4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3% GPC200D GPM200D 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +24 V 0 A 3 A 5 A 6.5 A 240 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3% 4 12 V (D) 0 A 3 A 4 A 4.5 A 120 mV 3% GPC200E GPM200E 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +24 V 0 A 3 A 5 A 6.5 A 240 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.5 A 150 mV 3% 4 15 V (D) 0 A 3 A 4 A 4.5 A 150 mV 3% GPC200F GPM200F 1 +5 V 4 A 18 A 26 A 32 A 50 mV 2% 2 +12 V 0 A 5 A 8 A 12 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.5 A 120 mV 3% 4 5 V (D) 0 A 3 A 4 A 4.5 A 50 mV 3% A. T otal regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Ratings for unrestricted natural convection cooling; outputs 1 & 2 combined load not to exceed 22A continuous; total power -150W. C. Ratings with 26cfm forced air cooling; outputs 1 & 2 combined load not to exceed 32A continuous; total power -200W. D. Isolated output which may be referenced as a positive or negative voltage. GPC200/GPM200 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 95% R 0 to 95% R before application of power. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Sg hock (B) 20 40 g pk pk orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. At ltitude-t 500 to 10,000 f -500 to 40,000 f C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929  805-486-4565  FAX 805-487-8911  www.condorpower.com 65

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the GPC200E?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SL Power / Condor Power CPQ400 Power Supply Assembly

product

SL Power/Condor Power F24-12-A+ Power Supply. Open Frame | 288 Watts | 24 VDC @ 12 A | 100-240 VAC

product

SL Power / Condor Power GLC110-12 Power Supply. Open Frame | Commercial | 110 W | 12V @ 6.3A Single ...

product

SL Power / Condor Power GLC110-212 Power Supply. Open Frame | Commercial | 110 W | 12V @ 6.3A, -12V ...

product

PWR SPLY SWITCHER 110W MULTI

product

SL Power / Condor Power GLM110-12 Power Supply. Open Frame | Medical | 110 W | 12 VDC @ 6.3A Single ...