Description

SL Power/Condor Power GLC75D Switch - 75 Watt Single Output Global Performance Switchers

Part Number

GLC75D

Price

Request Quote

Manufacturer

SL POWER

Lead Time

Request Quote

Category

Switches

Specifications

Ac Input

90-264 Vac, 47-63 Hz single phase.

Efficiency

68% -78% depending on model and load distribution

EMI/EMC Compliance

All models include built-in EMI filtering to meet the following emissions requirements: Conducted Emissions-GLC75:EN55022 Class B; FCC Class B; Conducted Emissions-GLM75:EN55011 Class B; FCC Class B; Static Discharge:EN61000-4-2, 6 kV contact, 8 kV air; RF Field Susceptibility:EN61000-4-3, 3 V/meter; Fast Transients/Bursts:EN61000-4-4, 2 kV, 5 kHz; Surge Susceptibility:EN61000-4-5, 1 kV diff., 2 kV com.; Line Frequency Harmonics:EN61000-3-2 Class A

Hold Up Time

20 ms minimum from loss of ac input power at full load, nominal line (120 Vac).

Input Current

Maximum input current at 120 Vac, 60 Hz with full rated output load not to exceed 2.3 A.

Input Protection

Internal ac fuse provided on all units. Designed to blow only if a catastrophic failure occurs in the unit.

Inrush Current

Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A.

Output Noise

0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.

Output Power

Normal continuous output power is 75 W for unrestricted natural convection cooling. The standard power is 110 W with 26 cfm airflow. During peak load conditions output regulation may exceed total regulation and noise limits.

Output Regulation

Measured by ±40% load change from 60% rated load with all other outputs at 60% rated load and input voltage change from minimum to maximum ratings. Output #1 requires 20% minimum load for proper regulation of other outputs. Initial set tolerance is measured with all outputs at 60% of full rated load. Output #2 requires 0.5 a minimum load for proper regulation.

Overload Protection

Factory set to begin power limiting at approximately 120 W. Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit.

Overvoltage Protection

Built in on V1 with firing point set per table. OVP firing reduces output #1 and #2 to less than 50% of nominal voltage in 50 ms.

Power Fail

A standard TTL or CMOS compatible output goes low (

Temperature Coefficient

0.03%/°C typical on all outputs.

Transient Response

Main Output: 500µSec typical response time for return to within 0.5% of final value for a 50% load step change, ?i/?t

Voltage Adjust

Factory set on standard unit; however, optional potentiometer adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output. Note: Output #1 must not be more than 1% below nominal to achieve full output voltage range on Output #2. Output regulation limits in some models may be exceeded when the main output is adjusted beyond +1% of nominal voltage. High voltage settings may degrade the reliability of the unit due to excessive power dissipation in some outputs.

Features

Datasheet

pdf file

GLC75D.pdf

212 KiB

Extracted Text

GLC75 Commercial/GLM75 Medical 75 Watt Multiple Output Global Performance Switchers FEATURES: Cost-effective multiple output power source Universal input 90-264 Vac 7.00”x 4.25”x 1.30” (Meets 1U height) 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Complies with EN61000-3-2 Class A Also available in single output versions Commercial UL1950, CSA22.2 No. 234 and IEC950 and EN60950 approvals Medical Approved to UL2601-1, IEC601-1 and CSA-C22.2 No. 601.1 SPECIFICATIONS: marked to LVD Ac Input 90-264 Vac, 47-63 Hz single phase. Input Protection Input Current Internal ac fuse provided on all units. Designed to blow Maximum input current at 120 Vac, 60 Hz with full rated only if a catastrophic failure occurs in the unit. output load not to exceed 2.3 A. Inrush Current Output Power Inrush limited by internal thermistors. Inrush at 240 Vac, Normal continuous output power is 75 W for unrestricted averaged over the first ac half-cycle under cold start natural convection cooling. The standard power is 110 W conditions will not exceed 37 A. with 26 cfm airflow. During peak load conditions output regulation may exceed total regulation and noise limits. Hold Up Time 20 ms minimum from loss of ac input power at full load, Output Regulation nominal line (120 Vac). Measured by ±40% load change from 60% rated load with all other outputs at 60% rated load and input voltage Temperature Coefficient change from minimum to maximum ratings. Output #1 0.03%/°C typical on all outputs. requires 20% minimum load for proper regulation of other outputs. Initial set tolerance is measured with all outputs at Power Fail 60% of full rated load. Output #2 requires 0.5 a minimum A standard TTL or CMOS compatible output goes low load for proper regulation. (< 0.5 V) 5ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. Signal is Overload Protection factory set to trip on 84 to 94 Vac brown-out depending Factory set to begin power limiting at approximately 120 W. upon incoming line impedance and distortion. Other Fully protected against short circuit and output overload. settings are available through adjustment of built-in Short circuit protection is cycling type power limit. potentiometer (consult factory for assistance). Output will stay low for 20 ms minimum. Output Noise 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. EMI/EMC Compliance Measured with noise probe directly across output terminals All models include built-in EMI filtering to meet the of the power supply. following emissions requirements: Transient Response EMI SPECIFICATIONS COMPLIANCE LEVEL Main Output: 500µSec typical response time for return to Conducted Emissions-GLC75 EN55022 Class B; FCC Class B within 0.5% of final value for a 50% load step change, Δi/ Conducted Emissions-GLM75 EN55011 Class B; FCC Class B Δt<0.2A/µSec. Maximum voltage deviation is 3.5%. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Overvoltage Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Built in on V1 with firing point set per table. OVP firing Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. reduces output #1 and #2 to less than 50% of nominal Line Frequency Harmonics EN61000-3-2 Class A voltage in 50 ms. Commercial Safety Voltage Adjust All GLC models are approved to UL1950, CSA22.2 No. Factory set on standard unit; however, optional potentiom- 234 Level 3, IEC950 and EN60950. Consult factory for eter adjusts voltage from 4.7 V to OVP point (6.2 V nominal) approval status. on the +5 V output. Note: Output #1 must not be more than 1% below nominal to achieve full output voltage range on Medical Leakage Current Output #2. Output regulation limits in some models may be 70 µA 264 V @ 50 Hz (normal conditions). exceeded when the main output is adjusted beyond +1% of nominal voltage. High voltage settings may degrade the Medical Safety reliability of the unit due to excessive power dissipation in All GLM models are approved to UL2601-1, CSA-C22.2 some outputs. No. 601.1, IEC601-1 and EN60601. Consult factory for Efficiency approval status. 68% -78% depending on model and load distribution. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565  FAX 805-487-8911  www.condorpower.com 42 GLC75 Commercial/GLM75 Medical 75 Watt Multiple Output Commercial Medical Output Maximum Output Maximum Output Minimum Model Model Output No. Output (A) (B) Output Peak V1 OVP Set Noise P-P Regulation GLC75A GLM75A 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 12 0A .5 2A .5 3A4V1) 20 m +10%, -5% (D 3V-A 12 0A1A1A1V .2 1% 20 m 3 4V+A 12 0A2A .5 3A4V1% 20 m 2 GLC75B GLM75B 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 12 0A .5 2A .5 3A4V1) 20 m +10%, -5% (D 3V-A 5 0A1A1A1V .2 5% 0 m 3 4V+A 12 0A2A .5 3A4V1% 20 m 2 GLC75C GLM75C 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 12 0A .5 2A .5 3A4V1) 20 m +10%, -5% (D 3V-A 15 0A1A1A1V .2 1% 50 m 3 4V+A 15 0A2A .5 3A4V1% 50 m 2 GLC75D GLM75D 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 24 0A .5 2A .5 2A .53V .5 2) 40 m +10%, -5% (D 3V-A 12 0A1A1A1V .2 1% 20 m 3 4V+A 12 0A2A .5 3A4V1% 20 m 2 GLC75E GLM75E 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 24 0A .5 2A .5 2A .53V .5 2) 40 m +10%, -5% (D 3V-A 15 0A1A1A1V .2 1% 50 m 3 4V+A 15 0A2A .5 3A4V1% 50 m 2 GLC75F GLM75F 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 15 0A .5 2A .5 3A4V1) 50 m +10%, -5% (D 3V-0 5 1A A 1A1V .2 5% 0 m 3 4V-0 15 2A .5A 3A4V1% 50 m 2 GLC75H GLM75H 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.6 5% 0 m 2 2V+A 15 0A .5 2A .5 3A4V1) 50 m +10%, -5% (D 3V-0 15 1AA 1A1V .2 1% 50 m 3 4V+0 15 2A .5A 3A4V1% 50 m 2 GLC75J GLM75J 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.65% 0 m 2 2V+A 12 0A .5 2A .5 3A4V1) 20 m +10%, -5% (D 3V-0 12 1AA 1A1V .2 1% 20 m 3 4V (C) 50 2A .0A 3A4V5% 0 m 2 GLC75P GLM75P 1V+A 5.1 1A8A1A 0 1V 2 6V .2 ± 0.65% 0 m 2 2V+A 24 0A .5 4A4A4V .5 2) 40 m +10%, -5% (D 3V-A 12 0A1A1A1V .2 1% 20 m 3 4V+A 12 0A2A .5 3A4V1% 20 m 2 A. Rating with unrestricted convection cooling. Total power not to exceed 75 W. B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W. C. Floating fourth output can be referenced as either positive or negative. Connect pin 12 to Return to provide a positive voltage at Pin 13. Connect pin 13 to Return to provide a negative voltage at Pin 12. D. To maintain these regulations conditions, the +5V current must be at least 1/5 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted to within 1% with at least a 1 A load to maintain regulation on this output. GLC75/GLM75 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o o T0 emperature (A) 0 to 5C5 -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total output power by 2.5% HH umidity (A)0H to 95% R 0 to 95% R per °C above 50°C. Sg hock (B) 20 40 g pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. At ltitude-t 500 to 10,000 f -500 to 40,000 f C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929  805-486-4565  FAX 805-487-8911  www.condorpower.com 43

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the GLC75D?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SL Power/Condor Power GLC50-12 Switch - Power Supply, Switching; 50 W; 90 to 264 VAC; 12 V; 1.5 A (M...

product

SL Power/Condor Power GPC130B Switch - Power Supply; 4; 85 to 264 VAC; 3.5 A (Max.) @ 120 VAC, 60 Hz...

product

SL Power/Condor Power GPC80-24-G 80 Watt Global Single Commercial Output Performance Switcher

product

SL POWER / CONDOR POWER GPFC160-28 Switch - 160 Watt Global Performance Switchers

product

SL Power / Condor Power GPFM250-24 Switcher - 3.6 watts/cu.in. power density; Compact size (5.0" x 8...

product

SL Power/Condor Power GPM130E Switch - 130W Global Switching power supply, medical grade