Details

Part Number V640-HAM11-L
Manufacturer OMRON
Category Systems
Price Request Quote
Lead Time Request Quote

Description

Omron V640-HAM11-L CIDRW Controller

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a V640-HAM11-L? We can help you find it at a competitive price!

Specifications

Ambient operating humidity 35% to 85% (with no condensation)
Ambient operating temperature 0 to 40°C (with no icing)
Ambient storage humidity 35% to 85% (with no condensation)
Ambient storage temperature -15 to 65°C (with no icing)
Case ABS+PC
Current consumption 400mA or less
Degree of Protection IEC60529: IP20
Dielectric Strength 1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal (leakage current: 5 mA max.)
Ground Ground at a resistance of less than 100 O.
Host Interface RS-232C/RS-485
Insulation resistance 20 MO min. (at 100 VDC) between the power supply terminals and the frame ground terminal
Power supply voltage 24 VDC (max. fluctuation 20.4 to 26.4 VDC)
Shock Resistance 150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Vibration Resistance 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and Z directions
Weight Approx. 250 g

Datasheet

Download "omron-v640_series_ds-56176713.pdf" (1639 KiB)

Extracted Text

RFID System (Conforms to SEMI standard, Electromagnetic Inductive 134 kHz) V640 Series CSM_V640_Series_DS_E_3_1 Line-up Ethernet I/F model newly. RFID system for Semiconductor applications, supports reading and writing TI (Texas Instruments) transponders ■ Conforms to SEMI standards (E4, E5, E99, E15.1) ■ Supports SECS commands ( via CIDRW Controller Model. V700-L22) ■ Embedded Web browser function provides easy configuration and read/write testing (Ethernet type only) ■ Enhanced functions, TEST Mode / Detecting for CIDRW Head status ■ Conformed to many local Radio regulations. (CE / FCC / IC/Korea/China/Taiwan/Singapore/Indonesia) Be sure to read the “Safety Precautions” on page 8 System Configuration Standard Models RS-232C/RS-485 ID Tag Amplifier Unit HOST CIDRW Head original command CIDRW Controller RS-232C SECS I/II protocol RI-TRP-DR2B(-30) V640-HAM11-V3 RI-TRP-WR2B(-30) PC RI-TRP-IR2B(-30) RI-TRP-RR2B(-30) Amplifier Unit * V700-L22 Texas Instruments V640-HS61 Ethernet TCP/IP original command PLC V640-HAM11-ETN Long-range Communications Model RS-232C/RS-485 ID Tag Amplifier Unit HOST CIDRW Head original command CIDRW Controller RS-232C SECS I/II protocol RI-TRP-DR2B(-30) V640-HAM11-L RI-TRP-WR2B(-30) PC * Texas Amplifier Unit Instruments V700-L22 V640-HS62 Ethernet TCP/IP original command PLC V640-HAM11-L-ETN Note: 1. Use of the V700-L11 ID Link Unit enables the Amplifier Unit to be removed/installed while the CIDRW System remains turned ON in the event of a malfunction or during maintenance. 2. Use the V700-L22 CIDRW Controller when using SECS communications protocol. 3. Refer to the User’s Manual (V640-HAM11-V3,V640-HAM11-L: Cat. No. Z307; V640-HAM11-L-ETN,V640-HAM11-ETN: Cat. No. Z308) for details. ✽Communication performance does not guarantee. 1 RFID System (Conforms to SEMI standard, Electromagnetic Inductive 134 kHz) V640 Series Enables reading and writing transponders V640-HAM11-V2 Product Discontinuation for various Semiconductor applications, (End of October, 2011) such as FOUPs (Front-Opening Unified Pods), reticles, and pods. ■ Antenna dimensions conform to SEMI E15.1. ■ Conforms to Carrier Reader/Writer-related SEMI standards; SEMI E99, E4, and E5. ■ V700-L22 conforms to SEMI standard E99-0303 (issued March 2003). ■ Lineup incudes compact models designed for long-range communications. ■ CE marking/FCC approvals Be sure to read the “Safety Precautions” on page 8 System Configuration Standard Models ID Tag Amplifier Unit HOST CIDRW Head RS-232C/RS-485 original command RI-TRP-DR2B(-30) PC RI-TRP-WR2B(-30) * CIDRW Controller Texas RS-232C Instruments SECS I/II protocol V640-HS61 V640-HAM11-V2 Product Discontinuation (End of October, 2011) PLC V700-L22 Long-range Communications Model ID Tag Amplifier Unit HOST CIDRW Head RS-232C/RS-485 original command RI-TRP-DR2B(-30) RI-TRP-WR2B(-30) PC * CIDRW Controller Texas RS-232C Instruments SECS I/II protocol V640-HS62 V640-HAM12 PLC V700-L22 Note: 1. Use of the V700-L11 ID Link Unit enables the Amplifier Unit to be removed/installed while the CIDRW System remains turned ON in the event of a malfunction or during maintenance. 2. Use the V700-L22 CIDRW Controller when using SECS communications protocol. 3. Refer to the User’s Manual (V640-HAM11-V2: Cat. No. Z167; V640-HAM12: Cat. No. Z218) for details. ✽Communication performance does not guarantee. 2 V640 Series Ordering Information List of Models Name Appearance Size Specifications Model 50 × 30 × 12 mm (including Standard Models V640-HS61 mounting plate) 2-meter cable CIDRW Head Long-range 65 × 30 × 12 mm (including Communications Model V600-HS62 mounting plate) 1.9-meter cable RS-232C interface 80 × 185 × 43 mm RS-485 interface V640-HAM11-V3 24 VDC Ethernet interface 80 × 185 × 43 mm V640-HAM11-ETN 24 VDC RS-232C interface 80 × 185 × 43 mm RS-485 interface V640-HAM11-L 24 VDC Amplifier Unit Ethernet interface 80 × 185 × 43 mm V640-HAM11-L-ETN 24 VDC V640-HAM11-V2 80 × 185 × 43 mm Product Discontinuation (End of October, 2011) RS-232C interface RS-485 interface 24 VDC 80 × 125 × 43 mm V640-HAM12 24 VDC RS-232C interface CIDRW Controller 150 × 167 × 28 mm V700-L22 (Compatible with SECS I/II protocol.) 24 VDC ID Link Unit 110 × 65 × 64 mm RS-232C interface V700-L11 RS-485 interface Power Supply Connector (1) Connector accessories for Power Supply Connector Pins (3) V640-A90 ✽ the V640 Amplifier Unit RS-485 Port Connector (1) ✽V640-A90 includes all of these accessories as a set. To purchase individual accessories, contact the manufacturers below directly. Purchasing Individual Accessories Name Model Manufacturer Power Supply Connector 1-178288-3 Tyco Electronics Power Supply Connector Pins 175217-3 RS-485 Port Connector MSTB2.5/2-STF-5.08 Phoenix Contact Inc. 3 V640 Series Specifications and Ratings CIDRW Head Model V640-HS62 V640-HS61 Item Transmission frequency 134 kHz Insulation resistance 20 MΩ min. (at 100 VDC) between the connector terminals and the case 1,000 VAC (50/60 Hz, 1 minute) between the connector terminals and the case (leakage current: 5 mA Dielectric strength max.) 2 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s acceleration with 10 sweeps of 8 min each in X, Y, and Vibration resistance Z directions 2 Shock resistance 150-m/s acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature 0 to 40°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Ambient storage temperature −15 to 65°C (with no icing) Ambient storage humidity 35% to 85% (with no condensation) Degree of protection IEC60529: IP20 Cable 2-m (3-mm dia.) coaxial cable 1.9-m (3-mm dia.) coaxial cable Case ABS/epoxy resin, stainless-steel mounting fixture Weight Approx. 70 g Approx. 100 g CIDRW Controller V640-HAM11-V3 V640-HAM11-L V640-HAM11-ETN V640-HAM11-L-ETN Model Item Host interface RS-232C/RS-485 Ethernet (TCP/IP) Power supply voltage 24 VDC (max. fluctuation 20.4 to 26.4 VDC) Current consumption 150mA or less 400mA or less 150mA or less 400mA or less Insulation resistance 20 MΩ min. (at 100 VDC) between the power supply terminals and the frame ground terminal 1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal Dielectric strength (leakage current: 5 mA max.) 2 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s acceleration with 10 sweeps of 8 min each in X, Y, and Vibration resistance Z directions 2 Shock resistance 150-m/s acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature 0 to 40°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Ambient storage temperature −15 to 65°C (with no icing) Ambient storage humidity 35% to 85% (with no condensation) Degree of protection IEC60529: IP20 Case ABS+PC Ground Ground at a resistance of less than 100 Ω. Weight Approx. 250 g 4 V640 Series Amplifier Unit Model V640-HAM11-V2 V640-HAM12 Item Host interface RS-232C (via dedicated 1:1 protocol or 1:N protocol) or RS-485 Power supply voltage 24 VDC (max. fluctuation 20.4 to 26.4 VDC) Current consumption 150mA or less 400mA or less Insulation resistance 20 MΩ min. (at 100 VDC) between the power supply terminals and the frame ground terminal 1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal Dielectric strength (leakage current: 5 mA max.) 2 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s acceleration with 10 sweeps of 8 min each in X, Y, and Vibration resistance Z directions 2 Shock resistance 150-m/s acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature 0 to 40°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Ambient storage temperature −15 to 65°C (with no icing) Ambient storage humidity 35% to 85% (with no condensation) Degree of protection IEC60529: IP20 Case SECC (coated) Ground Ground at a resistance of less than 100 Ω. Weight Approx. 500 g Approx. 400 g CIDRW Controller Model V700-L22 Item Host interface RS-232C Power supply voltage 24 VDC (max. fluctuation 20.4 to 26.4 VDC) Power consumption 150 mW max. Insulation resistance 50 MΩ min. (at 500 VDC) between the power supply terminals and the frame ground terminal 500 VAC (50/60 Hz, 1 minute) between the power supply terminals and the ground terminal (leakage Dielectric strength current: 3.5 mA max.) 2 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s acceleration with 10 sweeps of 8 min each in X, Y, and Vibration resistance Z directions 2 Shock resistance 150-m/s acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature 0 to 40°C (with no icing) Ambient operating humidity 10% to 85% (with no condensation) Ambient storage temperature −15 to 65°C (with no icing) Ambient storage humidity 10% to 95% (with no condensation) Degree of protection IEC60529: IP20 Ground Ground at a resistance of less than 100 Ω. Weight Approx. 580 g 5 V640 Series ID Link Unit Model V700-L11 Item Host interface RS-232C or RS-485 Power supply voltage 24 VDC (max. fluctuation 20.4 to 26.4 VDC) Power consumption 10 W max. Insulation resistance 50 MΩ min. (at 500 VDC) between the power supply terminals and the frame ground terminal 1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the frame ground terminal Dielectric strength (leakage current: 5 mA max.) 2 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s acceleration with 10 sweeps of 8 min each in X, Y, and Vibration resistance Z directions 2 Shock resistance 150-m/s acceleration for 3 times each in X, Y, and Z directions (18 times in total) Ambient operating temperature 0 to 40°C (with no icing) Ambient operating humidity 35% to 85% (with no condensation) Ambient storage temperature −15 to 50°C (with no icing) Ambient storage humidity 35% to 85% (with no condensation) Degree of protection IEC60529: IP20 Ground at a resistance of less than 100 Ω. If grounding is not performed properly, transmission Ground specifications may be adversely affected by the surrounding environment. Weight Approx. 200 g 6 V640 Series Functional Specifications Serial Type System Configuration Examples System Configuration Using CIDRW Controller (V700-L22) The Carrier ID Reader Writer (CIDRW) System is an RFID system that conforms to SEMI standards. The V700-L22 CIDRW Controller, the V640- HAM1@ Amplifier Unit, the V640-HS6@ CIDRW Head, and a Texas Instruments ID Tag can be used to configure a Carrier ID Reader Writer (CIDRW) System that conforms to the following standards: Note: SEMI: Semiconductor Equipment and Materials International SECS: SEMI Equipment Communications Standard CIDRW System Link Unit V700-L11 Just the relevant Amplifier Unit can be removed and replaced while the power remains on. RS-232C RS-232C SECS I/II RS-485 50 m max. Up to 31 Units can be connected. Ethernet Type System Configuration Examples Host device Ethernet HUB Amplifier Unit CIDRW Head V640-HAM11-ETN V640-HS61 LAN cable LAN cable Host computer, device controller, etc. Amplifier Unit CIDRW Head V640-HAM11-ETN V640-HS61 LAN cable Amplifier Unit CIDRW Head V640-HAM11-ETN V640-HS61 LAN cable The Amplifier Unit controls the The CIDRW Head is the CIDRW Head. antenna. It reads and writes carrier IDs and performs other processing for ID Tags. Note: If the IP address is set on the DIP switch, it will be in the form 192.168.1.@@@. The subnet mask is always 255.255.255.0. The IP address of the Amplifier Unit can be either set on this DIP switch or the desired IP address can be set in ROM. If pins 1 to 5 on the DIP switch are all turned OFF, the IP address that is set in ROM will be used. 7 V640 Series Safety Precautions Precautions for Correct Use WARNING Please observe the following precautions to prevent failure to The product is not designed or rated for ensuring the operate, malfunctions, or undesirable effects on product safety of persons. performance. Do not use it for such purposes. About installation Site Do not install this product in the locations subject to the following conditions. Precautions for Safe Use • Place where direct sunshine strikes. Please observe the following precautions for safe use of the • Place with corroded gas, dust, metallic powder, and salinity. products. • Place with condensation due to rapid temperature fluctuations. • Place with condensation due to high humidity. • Never use the product in an environment where combustible or • Place where vibration and impact more than being provided by explosivegas is present. specification are transmitted directly to main body. • Please separate from a high-pressure equipment and the power • Place with spray of water, oil, and chemical medicine. equipment to secure the safety of the operation and maintenance. • The working temperature is within the range stipulated in the • In the installation, please tighten the screw surely. (Recommended specifications. 1.2N.m) • Please do not insert foreign bodies such as water and the wires About depositoty Site from the space of the case. • Please follow the save ambient temperature / humidity, and keep • Please do not dismantle, repair or modify this product. this product. • Please process as industrial waste when you abandon this About wiring product. • When you work on wiring and put on and take off cables, CIDRW • Use the power supply voltage specified in this cocument. head, please perform it after switching off this product. • Ensure correct polarity when connecting to the +/- power supply • Provide enough space around this product for ventilation. terminals. • Please avoid installing this product near the machinery (a heater, • Do not run high-voltage lines and power lines though the same a transformer, large-capacity resistance) that has high the calorific conduit. value. hen you felt abnormality to this product, and having switched • To avoid static-induced failure, wear a wrist band or equivalent it off. means to release a static charge before touching a terminal or a signal line within a connector. Confirm the effects of radio waves on medical devices. The following • In using this product in EU association states, the cable for DC guideline is from JAISA (Japan Automatic Identification Systems power supply to this product must not be extended over 3m. Association). • When you put on and take off a CIDRW head, please do not add excessive power to a connector. This product is a reader-writer that uses radio waves for RFID equipment. • Please connect the correct CIDRW head to the amplifier unit. The application and location of this product may affect medical devices. The following precaution must be observed in the application of the product About cleaning to minimize the effects on medical devices. • Use alcohol to clean this product. Any person with an implanted medical device must keep the area where • Never use an organic solvent such as thinner, benzene, acetone the device is implanted at least 22 cm away from the antenna of a stationary or modular RFID device. or kerosene, as it will attack resin components or case coating. Power and Graound Cables • Use an appropriate ground. An insufficient ground can affect this product operation or result in damage to this product. About the communication range and time • Do the communication test with Transponder in the installation environment because the metal, noise and ambient temperature around CIDRW head damage to the communication range and time. • Install CIDRW head and ID tag in the appropriate distance because the communication range can change by the difference of ID tag specifications. 8 V640 Series About mounting • This product communicates with ID Tags using the 134 kHZ frequency band. Some transceivers, motors, monitoring equipment, and power supplies (power supply ICs) generate electrical waves (noise) that interfere with communications with ID Tags, If you are using the product in the vicinity of any of these devices, check the effect on communications in advance. • In order to minimize the effects of noise, ground nearby metal bodies with a grounding resistance not exceeding 100 ohms. • When mounting CIDRW Heads, tighten the screws tightly. (Recommended 0.6N·m) • When multiple CIDRW Heads are mounted next to each other, communications performance could be impaired by mutual interference. Read and follow the information in User's Manual on mutual interference when installing multiple heads. Screw Locking Adhesive • Screw locking adhesive (screw lock) may cause deterioration and cracking of resin parts; do not use it for screws in resin parts or anywhere where resin washers are used. Communications with the Host Device (V640-HAM11-V3/V640-HAM11-L Only) • Communicate with the host device only after confirming that the CIDRW Controller has started. Also, unstable signals may occur at the host interface when the CIDRW Controller is started. When initializing operation, clear the reception buffer at the host device or take other suitable methods to clear unwanted signals. Startup Precaution • Never turn OFF the power supply while the CIDRW Controller is starting, including when power is turned ON, when the mode is changed, or when the CIDRW Controller is being reset. Doing so may damage the CIDRW Controller. Application Precaution (V640-HAM11-ETN/V640-HAM11-L-ETN Only) • Never turn OFF the power supply while setting the IP address, subnet mask, or Web password. Doing so may damage the Amplifier Unit. 9 V640 Series Dimensions (Unit: mm) CIDRW Head V640-HS61 Four, 3.5 dia. (mounting holes) Antenna center Mounting Hole Dimensions Connector 9 4-M3 or 3.5 dia. 3.0-dia. coaxial cable, standard length 2 m Antenna center 30 20 12 10 20±0.2 21 29.2 50 9 21±0.2 12 4 V640-HS62 Four, 3.5 dia. (mounting holes) Connector 3.011-dia. coaxial cable, length 1.9 m Antenna center 9 Mounting Hole Dimensions Antenna center 4-M3 or 3.5 dia. 30 20 12 10 28 max. 21 20±0.2 39.2 Ferrite core 65 49 9 21±0.2 12 14.5 20.5 max. 4 10 V640 Series Amplifier Unit V640-HAM11-V3 (30.2) DC power supply connector (15.8) (18.2) V640-HAM11-L Four operation indicator lamps 55.5 RS-485 connector 6.8 6.8 (17.75) 80 (13) (12) 6.8 56 0.6 (12) 46 (22.5) (32.5) 160 RS-232C connector 175 DIP switch 185 Four, 4.5 dia. (mounting holes) (4.2) (11.5) 43 (1) (32.5) (5.7) 5 Mounting Hole Dimensions 175±0.5 46±0.5 4-M4 V640-HAM11-ETN DC power supply connector V640-HAM11-L-ETN (15.8) (18.2) Four operation indicator lamps 55.5 MAC address label 6.8 6.8 80 (13) (12) 6.8 56 0.6 46 (18) (22.5) (31.95) 160 Ethernet connector 175 DIP switch 185 Four, 4.5 dia. (mounting holes) (11.5) 43 (32.5) (5.7) 5 Mounting Hole Dimensions 175±0.5 46±0.5 4-M4 11 V640 Series Amplifier Unit 43 (30.5) 185 V640-HAM11-V2 2 160 (15.8) 6.8 6.8 (17.8) (13) (12) 6.8 46 56 80 0.6 (12) (18.2) 55.5 (32.5) Four operation 175 indicator lamps DIP switch (4.5) (11.6) Four, 4.5 dia. (mounting holes) 1 (1.5) Mounting Hole Dimensions 175±0.5 46±0.5 4-M4 (30.5) 125 43 V640-HAM12 2 100 (15.8) 6.8 6.8 (17.8) 6.8 (13) (12) 4.6 46 56 80 (12) (32.5) 33.5 Four operation (16) indicator lamps 115 DIP switch (4.5) (11.6) Four, 4.5 dia. (mounting holes) 1 (1.5) Mounting Hole Dimensions 115±0.5 46±0.5 4-M4 12 V640 Series CIDRW Controller V700-L22 150 28 130 Mounting Hole Dimensions Power lamp 130±0.2 4-M4 151 167 3 Operation 151±0.2 indicator lamps 24 7 P6×3 Four, 4.5 dia. (mounting holes) 30 ID Link Unit V700-L11 110 110 41.5 41.5 26.5 41.3 18.5 20.3 Mounting Hole Dimensions 16.7 10.7 35.2 65 55±0.2 5 2-M4 or 4.2 dia. 100±0.2 Two, 4.5 dia. 4 4 60 13 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. · Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. · Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.

Related Products

OMRON
Omron 3G3SV-BB004-E-TF Drive System
OMRON
Omron V640-HAM11-ETN CIDRW Controller
OMRON
Omron V640-HAM11-L-ETN CIDRW Controller
OMRON
Omron V640-HAM11-V3 CIDRW Controller
OMRON
Omron V700-L11 ID Link Unit

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 5.019 seconds.