Industrial Trading chervon right Manufacturers chervon right O chervon right OMRON chervon right S8VS09024A
About product Datasheet FAQ

OMRON S8VS09024A

Image of OMRON S8VS09024A

Description

Omron S8VS09024A 24VOUT, 100-240IN; power supply, 90W, 100-240 VAC input, 24 VDC 3.75A output, din rail mounting, digital display with running voltage and current, peak current, and main

Part Number

S8VS09024A

Price

Request Quote

Manufacturer

OMRON

Lead Time

Request Quote

Category

Power Supply

Datasheet

pdf file

Omron-S8VS Series-datasheet1-1051250194.pdf

122 KiB

Extracted Text

Switching Power Supply S8VS (15/30/60/90/120/180/240-W Models) Wide Range of DIN-Rail Mount Micro Power Supplies with LED Display • 3-digit, 7-segment LED display shows status at a glance for output voltage, output current, peak current, lifetime years, and run time hours.  Incorporates a maintenance forecast monitor that displays the remaining life of the power supply, displayed in years.  Run-time monitor model displays how long the output has been on, displayed in thousands of hours.  15 and 30 W models have 22.5 mm width, which saves panel space.  60, 90, 120, 180 and 240 W models have LED Displays.  90, 120, 180 and 240 W LED models have two outputs; one for undervoltage output and one for either the lifetime monitor or run-time monitor.  All models are Lead-free. Approvals  15 and 30 W models cULus, UL508 listed, Class 2 output, Class I Division 2  60 W model cULus, UL508 listed, Class 2 output, SEMI F47  90, 120, 180 and 240 W models cULus, UL508 listed  All models are CE marked. Warranty  All models have a 3-year warranty. Switching Power Supply S8VS 1 Model Number Structure ■ Model Number Legend S8VS- @@@@@@@ 12 3 1. Power Ratings 3. Configuration 90-W, 120-W, 180-W, 240-W Models 015: 15 W 15-W, 30-W Models None: Standard (No Display) 030: 30 W None: Standard (No Display) A: With maintenance forecast monitor and undervoltage alarm 060: 60 W (transistor (sinking)) 090: 90 W 60-W Models B: With total run time monitor and un- 120: 120 W None: Standard (No Display) dervoltage alarm 180: 180 W A: With maintenance forecast monitor (transistor (sinking)) 240: 240 W B: With total run time monitor AP: With maintenance forecast monitor 2. Output voltage and undervoltage alarm (transistor (sourcing)) 05: 5 V BP: With total run time monitor and un- 12: 12 V dervoltage alarm 24: 24 V (transistor (sourcing)) Ordering Information Stock Note: Shaded models are normally stocked. Power ratings Input voltage Output voltage Output current Alarm output Model number 15 W 100 to 240 VAC 5 V 2.0 A --- S8VS-01505 (See note 1.) 12 V 1.2 A S8VS-01512 24 V 0.65 A S8VS-01524 30 W 5 V 4.0 A --- S8VS-03005 (See note 2.) 12 V 2.5 A S8VS-03012 24 V 1.3 A S8VS-03024 60 W 24 V 2.5 A --- S8VS-06024 S8VS-06024A S8VS-06024B 90 W 3.75 A --- S8VS-09024 Sinking S8VS-09024A Sourcing S8VS-09024AP Sinking S8VS-09024B Sourcing S8VS-09024BP 120 W 5 A --- S8VS-12024 Sinking S8VS-12024A Sourcing S8VS-12024AP Sinking S8VS-12024B Sourcing S8VS-12024BP 180 W 7.5 A --- S8VS-18024 Sinking S8VS-18024A Sourcing S8VS-18024AP Sinking S8VS-18024B Sourcing S8VS-18024BP 240 W 10 A --- S8VS-24024 Sinking S8VS-24024A Sourcing S8VS-24024AP Sinking S8VS-24024B Sourcing S8VS-24024BP Note: 1. The output capacity of the S8VS-01505 is 10 W. 2. The output capacity of the S8VS-03005 is 20 W. 3. Optional mounting brackets are shown on page 21. 2 Switching Power Supply S8VS Specifications ■ Ratings/Characteristics Power ratings 15 W 30 W Type Standard Standard Item Efficiency (typical) 5-V models 72% min. 70% min. 12-V models 74% min. 76% min. 24-V models 77% min. 80% min. Input Voltage 100 to 240 VAC (85 to 264 VAC) Frequency 50/60 Hz (47 to 450 Hz) Current 100 V input 0.45 A max. 0.9 A max. 200 V input 0.25 A max. 0.6 A max. Power factor --- Harmonic current emissions Conforms to EN61000-3-2 Leakage current 100 V input 0.5 mA max. 200 V input 1.0 mA max. Inrush current 100 V input 25 A max. (for a cold start at 25°C ) (See note 1.) 200 V input 50 A max. (for a cold start at 25°C ) Output Voltage adjustment range −10% to 15% (with V.ADJ) (guaranteed) (See note 2.) Ripple 2.0% (p-p) max. (at rated input/output voltage) Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence 2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load) (rated input voltage) Temperature variation influence 0.05%/°C max. Start up time (See note 1.) 100 ms max. (at rated input/output voltage) 1,000 ms max. (at rated input/output voltage) Hold time (See note 1.) 20 ms min. (at rated input/output voltage) Additional Overload protection (See note 1.) 105% to 160% of rated load current, voltage drop, automatic reset 105% to 160% of rated load current, voltage drop, intermittent oper- functions ation, automatic reset Overvoltage protection Yes (a zener diode clamp) (See note 3.) Yes (See note 4.) (See note 1.) Output voltage indication No Output current indication No Peak-hold current indication No Maintenance forecast monitor indica- No tion Maintenance forecast monitor output No Total run time monitor indication No Total run time monitor output No Undervoltage alarm indication Yes (color: red) Undervoltage alarm output No Parallel operation No Series operation Models with 24-V output: Possible for up to 2 Power Supplies (with external diode) Models with 5- or 12-V output: Not possible Other Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage temperature −25 to 65°C Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 2 Shock resistance 150 m/s , 3 times each in ±X, ±Y, and ±Z directions Output indicator Yes (color: green) EMI Conducted Conforms to EN61204-3 EN55011 Class B and based on FCC Class A Emissions Radiated Conforms to EN61204-3 EN55011 Class B Emissions EMS Conforms to EN61204-3 Class B Approved standards UL: UL508 (Listing; Class 2: Per UL1310), UL60950-1, UL1604 (Class I/Division2) cUL: CSA C22.2 No.14 (Class 2), No.60950-1, No.213 (Class I/Division2) EN/VDE: EN50178 (=VDE0160), EN60950-1 (=VDE0805) SELV (EN60950/EN50178/UL60950-1) According to VDE0106/P100, IP20 Weight 160 g max. 180 g max. Note: 1. Refer to the Engineering Data section on page 17 for details. 2. If the V.ADJ adjuster is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 3. The overvoltage protection of the S8VS-015@@ uses a zener diode clamp. If the internal feedback circuit is destroyed by any chance, the load may be destroyed by the clamped output voltage (approx. 140% to 190% of the rated output voltage). 4. To reset the protection, turn OFF the power supply for three minutes or longer and then turn the power supply back ON. Switching Power Supply S8VS 3 Specifications ■ Ratings/Characteristics Power ratings 60 W 90 W Type Standard Maintenance Total run time Standard Maintenance forecast Total run time monitor forecast monitor monitor monitor Item Efficiency (typical) 78% min. 80% min. Input Voltage 100 to 240 VAC (85 to 264 VAC) Frequency 50/60 Hz (47 to 450 Hz) Current 100 V input 1.7 A max. 2.3 A max. 200 V input 1.0 A max. 1.4 A max. Power factor --- Harmonic current emissions Conforms to EN61000-3-2 Leakage current 100 V input 0.5 mA max. 200 V input 1.0 mA max. Inrush current 100 V input 25 A max. (for a cold start at 25°C ) (See note 1.) 200 V input 50 A max. (for a cold start at 25°C ) Output Voltage adjustment range −10% to 15% (with V.ADJ) (guaranteed) (See note 2.) Ripple 2.0% (p-p) max. (at rated input/output voltage) Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence 1.5% max. (with rated input, 0 to 100% load) (rated input voltage) Temperature variation influence 0.05%/°C max. Start up time (See note 1.) 1,000 ms max. (at rated input/output voltage) Hold time (See note 1.) 20 ms min. (at rated input/output voltage) Additional Overload protection (See note 1.) 105% to 160% of rated load current, voltage drop, intermittent, automatic reset functions Overvoltage protection Yes (See notes 1 and 3.) Output voltage indication (See note 4.) No Yes (selectable) (See note 5.) No Yes (selectable) (See note 5.) Output current indication (See note 4.) No Yes (selectable) (See note 6.) No Yes (selectable) (See note 6.) Peak-hold current indication No Yes (selectable) (See note 7.) No Yes (selectable) (See note 7.) (See note 4.) Maintenance forecast monitor indica- No Yes (selectable) No No Yes No tion (See note 4.) (selectable) Maintenance forecast monitor output No Yes No (open collector output), 30 VDC max., 50 mA max. (See note 8.) Total run time monitor indication No Yes No Yes (See note 4.) (selectable) (selectable) Total run time monitor output No Yes (open collector output), 30 VDC max., 50 mA max. (See note 8.) Undervoltage alarm indication No Yes (selectable) No Yes (selectable) (See note 4.) Undervoltage alarm output terminals No Yes (open collector output) 30 VDC max., 50 mA max. (See note 8.) Parallel operation No Series operation Yes for up to 2 Power Supplies (with external diode) Other Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage temperature −25 to 65°C Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 2 Shock resistance 150 m/s , 3 times each in ±X, ±Y, and ±Z directions Output indicator Yes (color: green) EMI Conducted Conforms to EN61204-3 EN55011 Class A and based on FCC Class A Emissions Conforms to EN61204-3 EN55011 Class B (See note 9.) Radiated Conforms to EN61204-3 EN55011 Class A Emissions Conforms to EN61204-3 EN55011 Class B (See note 9.) EMS Conforms to EN61204-3 Class B Approved standards UL: UL508 (Listing; Class 2: Per UL1310), UL60950 UL: UL508 (Listing), UL60950 cUL: CSA C22.2 No.14 (Class 2), No.60950 cUL: CSA C22.2 No.14, No.60950 EN/VDE: EN50178 (=VDE0160), EN60950 (=VDE0805) EN/VDE: EN50178 (=VDE0160), EN60950 (=VDE0805) SELV (EN60950/EN50178/UL60950-1) SELV (EN60950/EN50178/UL60950-1) According to VDE0106/P100, IP20 According to VDE0106/P100, IP20 Weight 330 g max. 490 g max. Note: 1. Refer to the Engineering Data section on page 17 for details. 2. If the V.ADJ adjuster is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models). When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 3. To reset the protection, turn OFF the power supply for three minutes or longer and then turn the power supply back ON. 4. Displayed on 7-segment LED. (character height: 8 mm) 5. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit) 6. Resolution of output current indication: 0.1 A; Precision of output current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage) 7. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage); Signal width required for peak-hold current: 20 ms 8. A Type and B Type: Sinking, AP Type and P Type: Sourcing 9. To ensure the emission rating, a ferrite ring core should be used in all cabling (TDK HF60T, HF70RH or equivalent model). 4 Switching Power Supply S8VS Power ratings 120 W 180 W 240 W Type Standard Maintenance Total run Standard Maintenance Total run Standard Maintenance Total run forecast time monitor forecast time monitor forecast time monitor Item monitor monitor monitor Efficiency (typical) 80% min. Input Voltage 100 to 240 VAC (85 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) Current 100 V input 1.9 A max. 2.9 A max. 3.8 A max. 200 V input 1.1 A max. 1.6 A max. 2.0 A max. Power factor 0.95 min. Harmonic current emissions Conforms to EN61000-3-2 Leakage current 100 V input 0.5 mA max. 200 V input 1.0 mA max. Inrush current 100 V input 25 A max. (for a cold start at 25°C) (See note 1.) 200 V input 50 A max. (for a cold start at 25°C) Output Voltage adjustment range −10% to 15% (with V.ADJ) (guaranteed) ±10% (with V.ADJ) (guaranteed) (See note 2.) Ripple 2.0% (p-p) max. (at rated input/output voltage) Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) Load variation influence 1.5% max. (with rated input, 0 to 100% load) (rated input voltage) Temperature variation influence 0.05%/°C max. Start up time (See note 1.) 1,000 ms max. (at rated input/output voltage) Hold time (See note 1.) 20 ms min. (at rated input/output voltage) Addition- Overload protection (See note 1.) 105% to 160% of rated load current, voltage drop, intermittent, automatic reset 105% to 160% of rated load al func- current, voltage drop, auto- tions matic reset Overvoltage protection Yes (See notes 1 and 3.) Output voltage indication (See note 4.) No Yes (selectable) (See note 5.) No Yes (selectable) (See note 5.) No Yes (selectable) (See note 5.) Output current indication (See note 4.) No Yes (selectable) (See note 6.) No Yes (selectable) (See note 6.) No Yes (selectable) (See note 6.) Peak-hold current indication No Yes (selectable) (See note 7.) No Yes (selectable) (See note 7.) No Yes (selectable) (See note 7.) (See note 4.) Maintenance forecast monitor indica- No Yes (select- No No Yes (select- No No Yes No tion (See note 4.) able) able) (selectable) Maintenance forecast monitor output No Yes (open No No Yes (open No No Yes (open No collector out- collector out- collector out- put), 30 VDC put), 30 VDC put), 30 VDC max., 50 mA max., 50 mA max., 50 mA max. max. max. (See note 8.) (See note 8.) (See note 8.) Total run time monitor indication No Yes No Yes No Yes (See note 4.) (selectable) (selectable) (selectable) Total run time monitor output No Yes (open No Yes (open No Yes (open collector out- collector out- collector out- put), 30 VDC put), 30 VDC put), 30 VDC max., 50 mA max., 50 mA max., 50 mA max. max. max. (See note 8.) (See note 8.) (See note 8.) Undervoltage alarm indication No Yes (selectable) No Yes (selectable) No Yes (selectable) (See note 4.) Undervoltage alarm output terminals No Yes (open collector output), No Yes (open collector output), No Yes (open collector output), 30 VDC max., 50 mA max. 30 VDC max., 50 mA max. 30 VDC max., 50 mA max. (See note 8.) (See note 8.) (See note 8.) Parallel operation No Series operation Yes for up to 2 Power Supplies (with external diode) Other Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation) Storage temperature −25 to 65°C Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 20 mA) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 2 Shock resistance 150 m/s , 3 times each in ±X, ±Y, and ±Z directions Output indicator Yes (color: green) EMI Conducted Conforms to EN61204-3 EN55011 Class A and based on FCC Class A Emissions Conforms to EN61204-3 EN55011 Class B (See note 9.) Radiated Conforms to EN61204-3 EN55011 Class A Emissions Conforms to EN61204-3 EN55011 Class B (See note 9.) EMS Conforms to EN61204-3 Class B Approved standards UL: UL508 (Listing), UL60950 cUL: CSA C22.2 No.14, No.60950 EN/VDE: EN50178 (=VDE0160), EN60950 (=VDE0805) SELV (EN60950/UL50178/UL60950-1) According to VDE0106/P100, IP20 Weight 550 g max. 850 g max. 1,150 g max. Switching Power Supply S8VS 5

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the S8VS09024A?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Omron 3G2A5-PS221-E power supply - POWER SUPPLY MODULE C500 24VDC FOR CPU

product

Omron CQM1-PA206 Power Supply Module AC 30Watt

Omron CV500-PS221 Power Supply | 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz ...

Omron CVM1-PA208 Power Supply Module CV/CVM1 AC | 100 to 120 or 200 to 240 VAC (automatic voltage se...

Omron S8E3-05031D Power Supply - POWER SUPPLY MULTI-OUTPUT