M-SYSTEMS M3LU
Specifications
‘One-Step Cal’ calibration
With I/O type and the full-scale range configured via the internal DIP switches, precise 0 % and 100% ranges are calibrated via the front control buttons with a help of LED.
AC Power input
Approx. 4 VA at 100 V; Approx. 5 VA at 200 V; Approx. 6 VA at 264 V
Burnout (T/C & RTD)
Upscale, downscale or no burnout selectable; Also detects wire breakdown and over-range input exceeding the electrical design limit for DC input.
Burnout response
Less than or equal to 10 sec
Cold junction compensation (T/C)
CJC sensor (included) to be attached to the input terminals
Cold junction compensation error
±0.5°C maximum at 10 – 40°C; ±1.0°C maximum at 0 – 50°C; ±0.9°F maximum at 50 – 104°F; ±1.8°F maximum at 32 – 122°F
Configuration
PC configurator
Connection
Euro type connector terminal
Construction
Small-sized front terminal structure
DC Power input
Approx. 2 W
Dielectric strength
AC powered: 2000 V AC @ 1 minute (input to output to power to ground); DC powered: 1500 V AC @ 1 minute (input to output or power to ground); 500 V AC @ 1 minute (output to power)
Housing material
Flame-resistant resin (gray)
Insulation resistance
Greater than or equal to 100 M Omega with 500 V DC
Isolation
Input to output to power
Line voltage effect
±0.1 % over voltage range
Max. 55°C (131°F) for UL approval
Installation
Mounting
DIN rail
Operating humidity
0 to 95 %RH (non-condensing)
Operating temperature
-25 to +65°C (-13 to +149°F)
Over-range output
-15 to +115 %
Response time
Less than or equal to 0.2 sec. (0 – 90 %, DC input)
Span adjustment
85 to 115 % (front)
Status indicator LED
Tri-color (green/amber/red) LED; Flashing patterns indicate operation status of the transmitter.
Temp. coefficient
±0.015 %/°C [±0.008 %/°F] at -5 to +55°C [23 to 131°F] of max. range
Weight
100 g (3.53 oz)
Zero adjustment
-15 to +15 % (front)
Features
- CE marking
- Easy ‘One-Step Cal’ calibration using the front three control buttons without needing a PC; PC software is also usable.
- Front control button function can be locked
- I/O type and ranges are configurable
- UL approval
- Universal input: mV, V, mA, T/C, RTD, resistance and potentiometer
Datasheet
Extracted Text
MODEL: M3LU Cu 10 @25°C, Pt 50Ω, JPt 100 Space-saving Signal Conditioners M3-UNIT Series Potentiometer Total resistance 80 – 4000 Ω UNIVERSAL TRANSMITTER Resistance (field- and PC-configurable) Total resistance 10 – 4000 Ω Functions & Features • Universal input: mV, V, mA, T/C, RTD, resistance and OUTPUT – Field-selectable potentiometer Current • Easy ‘One-Step Cal’ calibration using the front three 0 – 20 mA DC control buttons without needing a PC; PC software is also Voltage usable. -2.5 – +2.5 V DC • I/O type and ranges are configurable -10 – +10 V DC • Front control button function can be locked • CE marking • UL approval [1] POWER INPUT AC Power Typical Applications M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, • Signal conversion between control room and field 47 – 66 Hz) instrumentation with isolation (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) • Ideal for use as a fast solution, multifunctional spare part DC Power 18 (.71) R4: 10 – 32 V DC (Operational voltage range 9 - 36 V, ripple 10 %p-p max.) 106 [2] CONFIGURATION OPTIONS (4.17) A: PC and field configurable B: Field configurable 110.5 (4.35) [3] OPTIONS mm (inch) STANDARDS & APPROVALS blank: CE marking /UL: UL approval, CE marking MODEL: M3LU–[1]/[2][3] RELATED PRODUCTS ORDERING INFORMATION • PC configurator software (model: M3CFG) • Code number: M3LU-[1]/[2][3] Downloadable at M-System’s web site. Specify a code from below for each [1] through [3]. A dedicated cable is required to connect the module to the (e.g. M3LU-R4/A) PC. Please refer to the internet software download site or • Orders will be shipped with default factory settings (4 – 20 the users manual for the PC configurator for applicable mA input/4 – 20 mA output). cable types. INPUT – Field-selectable GENERAL SPECIFICATIONS DC Current & Voltage Construction: Small-sized front terminal structure Current: 0 – 20 mA DC Connection: Euro type connector terminal Millivolt: -1 – +1 V DC Housing material: Flame-resistant resin (gray) Voltage: -10 – +10 V DC Isolation: Input to output to power Thermocouple Overrange output: -15 to +115 % (PR), K, E, J, T, B, R, S, C (WRe 5-26), Zero adjustment: -15 to +15 % (front) N, U, L, P (Platinel II) Span adjustment: 85 to 115 % (front) RTD Burnout (T/C & RTD): Upscale, downscale or no burnout Pt 100, Pt 200, Pt 300, Pt 400, Pt 500, Pt 1000, selectable; Also detects wire breakdown and overrange Ni 100, Ni 120, Ni 508.4, Ni-Fe 604, input exceeding the electrical design limit for DC input. http://www.m-system.co.jp/ M3LU SPECIFICATIONS ES-2652 Rev.14 Page 1/6 MODEL: M3LU Cold junction compensation (T/C): CJC sensor (included) to output range provided that the minimum span is be attached to the input terminals maintained. Status indicator LED: Tri-color (green/amber/red) LED; Load resistance: Output drive 15 V maximum at 22 mA Flashing patterns indicate operation status of the ■ DC VOLTAGE transmitter. Narrow Spans (mV) Configuration: PC configurator Maximum range: -2.5 – +2.5 V DC Programmable features include: Minimum span: 250 mV • I/O type and range Conformance range: -3 – +3 V DC • Zero and span adjustments Wide Spans (V) • Burnout action Maximum range: -10 – +10 V DC • User’s linearization table setting Minimum span: 1 V • User’s TC/RTD table setting Conformance range: -11.5 – +11.5 V DC (Refer to the instruction manual) Offset: Lower range can be any specific value within the ‘One-Step Cal’ calibration: With I/O type and the full-scale output range provided that the minimum span is range configured via the internal DIP switches, precise 0 % maintained. and 100 % ranges are calibrated via the front control Load resistance: Output drive 10 mA maximum; 5 mA for buttons with a help of LED. negative output INPUT SPECIFICATIONS INSTALLATION Input type and range are configurable. See Table 1 for the Power Consumption available input type, the minimum span, the maximum •AC Power input: range, the conformance range and the input conversion Approx. 4 VA at 100 V accuracy. Approx. 5 VA at 200 V For type and range configuration, refer to the instruction Approx. 6 VA at 264 V manual. •DC power input: Approx. 2 W • DC current: 50 Ω resistor incorporated Operating temperature: -25 to +65°C (-13 to +149°F) • DC mV & voltage Max. 55°C (131°F) for UL approval Input resistance: ≥ 1 MΩ Operating humidity: 0 to 95 %RH (non-condensing) • Thermocouple Mounting: DIN rail Input resistance: ≥ 1 MΩ Weight: 100 g (3.53 oz) Burnout sensing: 130 nA ± 10 % • RTD (2-wire, 3-wire or 4-wire) PERFORMANCE Excitation: 0.2 mA ± 10 % Accuracy: See Table 1. Allowable leadwire resistance: Max. 20 Ω per wire Cold junction compensation error: • Resistance (2-wire, 3-wire or 4-wire) ±0.5°C maximum at 10 – 40°C Excitation: 0.2 mA ±10 % ±1.0°C maximum at 0 – 50°C Allowable leadwire resistance: Max. 20 Ω per wire ±0.9°F maximum at 50 – 104°F • Potentiometer ±1.8°F maximum at 32 – 122°F Excitation: 0.2 mA ±10 % Temp. coefficient: Allowable leadwire resistance: Max. 20 Ω per wire ±0.015 %/°C [±0.008 %/°F] at -5 to +55°C [23 to 131°F] of max. range OUTPUT SPECIFICATIONS ±0.03 %/°C [±0.016 %/°F] for the following conditions: Output type and range are as follows. • DC/TC input spans ≤ 10 mV For type and range configuration, refer to the instruction • RTD/POT, resistance spans ≤ 80 Ω manual. • in an ambient exceeding 55°C [131°F] or below -5°C ■ DC CURRENT [23°F] Maximum range: 0 – 20 mA DC Response time: ≤ 0.2 sec. (0 – 90 %, DC input) Minimum span: 1 mA With the Option A, the Sync Filter set to the fastest Conformance range: 0 – 24 mA DC frequency on the PC Configurator Software. Default is set to (Negative overrange current below 0 mA is not available.) have 0.5 sec. response. Offset: Lower range can be any specific value within the Burnout response: ≤ 10 sec. http://www.m-system.co.jp/ M3LU SPECIFICATIONS ES-2652 Rev.14 Page 2/6 MODEL: M3LU Line voltage effect: ±0.1 % over voltage range Low Voltage Directive (2006/95/EC) Insulation resistance: ≥ 100 MΩ with 500 V DC EN 61010-1: 2001 Dielectric strength Installation Category II AC powered: 2000 V AC @ 1 minute Pollution Degree 2 (input to output to power to ground) Input or output to power: Reinforced insulation (300 V) DC powered: 1500 V AC @ 1 minute Input to output: Basic insulation (300 V) (input to output or power to ground) Approval: 500 V AC @ 1 minute (output to power) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.1010-1) CALCULATION EXAMPLES OF OVERALL ACCURACY ■ CALCULATION EXAMPLES OF OVERALL ACCURACY IN % • DC Voltage 1) 0 – 200 mV Absolute value accuracy (Table 1): 40μV 40μV / 200000μV × 100 = 0.02 % < 0.1 % ➠ Overall accuracy = ±0.1 % of span 2) 0 – 4 mV Absolute value accuracy (Table 1): 10μV 10μV / 4000μV × 100 = 0.25 % > 0.1 % ➠ Overall accuracy = ±0.25 % of span • Thermocouple 1) K thermocouple, 0 – 1000°C Absolute value accuracy (Table 1): 0.25°C CJC error (0.5°C) added: 0.75°C 0.75°C / 1000°C × 100 = 0.075 % < 0.1 % ➠ Overall accuracy including CJC error = ±0.1 % of span 2) K thermocouple, 50 – 150°C Absolute value accuracy (Table 1): 0.25°C CJC error (0.5°C) added: 0.75°C 0.75°C / (150 – 50)°C × 100 = 0.75 % > 0.1 % ➠ Overall accuracy including CJC error = ±0.75 % of span • RTD 1) Pt 100, -200 – 800°C Absolute value accuracy (Table 1): 0.15°C 0.15°C / (800 – -200)°C × 100 = 0.015 % < 0.1 % ➠ Overall accuracy = ±0.1 % of span 2) Pt 100, 0 – 100°C Absolute value accuracy (Table 1): 0.15°C 0.15°C / 100°C × 100 = 0.15 % > 0.1 % ➠ Overall accuracy = ±0.15 % of span STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 http://www.m-system.co.jp/ M3LU SPECIFICATIONS ES-2652 Rev.14 Page 3/6 MODEL: M3LU EXTERNAL VIEW ■ FRONT VIEW ■ SIDE VIEW LED1 (LD1) 10 11 12 LED2 (LD2) Configuration DIP SW 7 8 9 LED3 (LD3) 4 3 2 1 MODE Button OFF UP Button ON DOWN Button SW1 Configurator Jack SW2 SW3 8 7 6 5 4 3 2 1 1 JP2 OFF 2 3 * 1 2 3 ON 4 5 6 *For Voltage Input (V) range, switch the JP2 jumper to the 2 – 3 position. Normal Position DC Voltage [V] Range Position (other than DC Voltage [V] range) JP2 JP2 1 2 3 1 2 3 http://www.m-system.co.jp/ M3LU SPECIFICATIONS ES-2652 Rev.14 Page 4/6 MODEL: M3LU INPUT TYPE, RANGE & ACCURACY Table 1. MIN. MAXIMUM 1 INPUT TYPE ACCURACY * SPAN RANGE DC Current 1mA 0 to 20mA ±0.1% DC Millivolt 4mV -1 to +1V ±10μV at F.S. input ≤50mV ±40μV at F.S. input ≤200mV ±60μV at F.S. input ≤500mV ±80μV at F.S. input >500mV DC Voltage 1V -10 to +10V ±0.1% Potentiometer 80Ω 0 to 4000Ω ±0.1% Resistance 10Ω 0 to 4000Ω ±0.1Ω °C °F Thermocouple MIN. MAXIMUM CONFORMANCE ACCURACY MIN. MAXIMUM CONFORMANCE ACCURACY SPAN RANGE RANGE *1 SPAN RANGE RANGE *1 (PR) 20 0 to 1760 0 to 1760 ±1.00 36 32 to 3200 32 to 3200 ±1.80 K (CA) 20 -270 to +1370 -150 to +1370 ±0.25 36 -454 to +2498 -238 to +2498 ±0.45 E (CRC) 20 -270 to +1000 -170 to +1000 ±0.20 36 -454 to +1832 -274 to +1832 ±0.36 J (IC) 20 -210 to +1200 -180 to +1200 ±0.25 36 -346 to +2192 -292 to +2192 ±0.45 T (CC) 20 -270 to +400 -170 to +400 ±0.25 36 -454 to +752 -274 to +752 ±0.45 B (RH) 20 100 to 1820 400 to 1760 ±0.75 36 212 to 3308 752 to 3200 ±1.35 R 20 -50 to +1760 200 to 1760 ±0.50 36 -58 to +3200 392 to 3200 ±0.90 S 20 -50 to +1760 0 to 1760 ±0.50 36 -58 to +3200 32 to 3200 ±0.90 C (WRe 5-26) 20 0 to 2315 0 to 2315 ±0.25 36 32 to 4199 32 to 4199 ±0.45 N 20 -270 to +1300 -130 to +1300 ±0.30 36 -454 to +2372 -202 to +2372 ±0.54 U 20 -200 to +600 -200 to +600 ±0.20 36 -328 to +1112 -328 to +1112 ±0.36 L 20 -200 to +900 -200 to +900 ±0.25 36 -328 to +1652 -328 to +1652 ±0.45 P (Platinel II) 20 0 to 1395 0 to 1395 ±0.25 36 32 to 2543 32 to 2543 ±0.45 °C °F RTD MIN. ACCURACY MIN. ACCURACY MAXIMUM RANGE MAXIMUM RANGE SPAN *1 SPAN *1 Pt 100 (JIS ’97, IEC) 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27 Pt 200 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27 Pt 300 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27 Pt 400 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27 Pt 500 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27 Pt 1000 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27 Pt 50 (JIS ’81) 20 -200 to +649 ±0.15 36 -328 to +1200 ±0.27 JPt 100 (JIS ’89) 20 -200 to +510 ±0.15 36 -328 to +950 ±0.27 Ni 100 20 -80 to +260 ±0.15 36 -112 to +500 ±0.27 Ni 120 20 -80 to +260 ±0.15 36 -112 to +500 ±0.27 Ni 508.4 20 -50 to +200 ±0.15 36 -58 to +392 ±0.27 Ni-Fe 604 20 -200 to +200 ±0.15 36 -328 to +392 ±0.27 Cu 10 @25°C 20 -50 to +250 ±0.50 36 -58 to +482 ±0.90 *1. DC input: Or ±0.1% of span, whichever is greater. Thermocouple input: [Accuracy + Cold Junction Compensation Error 0.5°C (0.9°F)] or ±0.1% of span, whichever is greater. RTD, Resistance input: Or ±0.1% of span, whichever is greater. For current output, overall accuracy degrades another 0.1% with spans ≤2mA. http://www.m-system.co.jp/ M3LU SPECIFICATIONS ES-2652 Rev.14 Page 5/6 MODEL: M3LU EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 10 11 12 7 8 9 DIN RAIL 35mm wide 1 2 3 4 5 6 110.5 (4.35) [5 (.20)] CJC SENSOR* 18 (.71) (model: CJM) *Used only with a thermocouple input • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM ■ DC POWERED TYPE STATUS CONTROL BUTTONS 2-wire 3-wire 4-wire POT. DIP SW Isolation RTD RTD RTD max. + Low Drift Input Input Output Output A A A 3 + 1 7 Amplifier Circuit Computation Computation Driver OUTPUT DC T/C – B B 2 8 ext. wire + 3 10 + VOLT + + mA + A 2 4 11 ** – mV – DC POWER * B B B 1 5 12 – – – – CJC min. SENSOR 6 9 CONFIGURATOR JACK Terminal Block ■ AC POWERED TYPE STATUS CONTROL BUTTONS 2-wire 3-wire 4-wire POT. DIP SW Isolation RTD RTD RTD max. + Low Drift Input Input Output Output A A A 3 1 7 + Amplifier Circuit Computation Computation Driver OUTPUT DC T/C – B B 2 8 ext. wire + 3 10 U VOLT + ** + + mA A 2 AC POWER 4 11 – mV – * B B B 1 5 12 V – – CJC – min. SENSOR 6 9 CONFIGURATOR JACK *Replace the Terminal Block (4 – 5 – 6) with the one connected with the CJC Sensor, included in the package. Terminal Block The CJC Sensor is secured to the terminal 6. ** Be aware that the AC power and DC power connect to different terminals . Loosen only the terminal 4 – 5 and connect the T/C extension wires. Specifications are subject to change without notice. http://www.m-system.co.jp/ M3LU SPECIFICATIONS ES-2652 Rev.14 Page 6/6 106 (4.17) 7 (.28) 62 (2.44)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M3LU?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.