M-SYSTEMS M2XUM
Specifications
Burnout (T/C, RTD and Pot.)
Upscale standard; downscale or no burnout options are PC programmable
Cold junction compensation (T/C)
CJC sensor (included) to be attached to the input terminals
Configurator connection
2.5 dia. miniature jack; RS-232-C level
Connection
M3 screw terminals (torque 0.8 N·m)
Construction
Plug-in
Housing material
Flame-resistant resin (black)
Isolation
Input to output to RS-485 to power
Linearization (T/C, RTD input)
Standard tables stored in memory
Manual span adjustments
95 to 105 % (factory setting
Manual zero adjustments
-5 to +5 % (factory setting
Over-range output
Approx. -15 to +115 % (Negative current output is not provided.)
Status indicator LED
Flashing patterns indicate different operating status of the transmitter.
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- Input and output ranges
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Simulated output
- Standard DIN rail or surface mounting
- T/C and RTD type and temp. range
- User's linearization table (max. 100 points, specified within -15 – +115 % for both input and output)
- Zero and span adjustments
Datasheet
Extracted Text
Model MODEL: M2XUM input type, please select from the following: Super-mini Signal Conditioners Mini-M Series Current Z1: Range 0 – 50 mA DC (Input resistance 100 Ω) UNIVERSAL TRANSMITTER Voltage (PC programmable; Modbus-RTU communication) S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.) Functions & Features S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.) • Accepts direct inputs from various sensors and provides a Thermocouple standard process signal T1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F) • I/O types and calibration ranges are fully programmable T2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F) via a PC T3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F) • Linearization up to 100 points can be programmed for DC T4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F) and potentiometer inputs T5: T (CC) (Usable range -270 to +400°C, -454 to +752°F) • Isolation between input – output – RS-485 – power T6: B (RH) (Usable range 0 to 1820°C, 32 to 3308°F) • CE marking T7: R (Usable range -50 to +1760°C, -58 to +3200°F) T8: S (Usable range -50 to +1760°C, -58 to +3200°F) Typical Applications T9: C(WRe 5-26) (Usable range 0 to 2315°C, 32 to 4199°F) • Signal conversion between control room and field TN: N (Usable range -270 to +1300°C, -454 to +2372°F) instrumentation with isolation TU: U (Usable range -200 to +400°C, -328 to +752°F) • Ideal for use as a fast solution, multifunctional spare part TL: L (Usable range -200 to +900°C, -328 to +1652°F) TP: Platinel Ⅱ(Usable range 0 to 1395°C, 32 to 2543°F) 29.5 (1.16) T0: Specify (Please provide an emf table.) RTD (2- or 3-wire) 76 R1: JPt 100 (JIS'89) (2.99) (Usable range: -200 to +500°C, -328 to +932°F) R3: Pt 100 (JIS'89) (Usable range: -200 to +850°C, -328 to +1562°F) 124 (4.88) R4: Pt 100 (JIS'97, IEC) mm (inch) (Usable range: -200 to +850°C, -328 to +1562°F) R5: Pt 50 Ω (JIS'81) (Usable range: -200 to +649 °C, -328 to +1200°F) MODEL: M2XUM–[1][2]–[3][4] R6: Ni 508.4 Ω (Usable range: -50 to +200°C, -58 to +392°F) ORDERING INFORMATION R7: Pt 1000 • Code number: M2XUM-[1][2]-[3][4] (Usable range: -200 to +200°C, -328 to +392°F) Specify a code from below for each [1] through [4]. R8: Ni 100 (100 Ω @ 0°C) (e.g. M2XUM-00-M2/CE/Q) (Usable range: -50 to +200°C, -58 to +392°F) • Specify the specification for option code /Q R9: Cu 10 (10 Ω @25°C) (e.g. /C01/S01) (Usable range: -50 to +200°C, -58 to +392°F) R0: Specify (Please provide a resistance table.) Non-specified orders will be shipped at default factory Potentiometer settings (M2XUM-00: 4 – 20 mA input/4 – 20 mA output). M: Total resistance 100 Ω – 10 kΩ However, the power suffix code must be specified. If you specify full code numbers without specific calibration [2] OUTPUT ranges, default settings will be used. 0: User-calibrated (Factory default: 4 – 20 mA DC) Note: Must be used with its socket. NOT installable to a multi-unit installation base. (e.g. model: M2BS-16) If the unit is to be factory-calibrated to a specific output type, please select from the following: [1] INPUT Current 0: User-calibrated (Factory default: 4 – 20 mA DC) Z1: Range 0 – 20 mA DC Voltage If the unit is to be factory-calibrated to a specific V1: Range -2.5 – +2.5 V DC http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 1/7 MODEL: M2XUM V2: Range -10 – +10 V DC · User’s TC/RTD table Burnout (T/C, RTD and Pot.): Upscale standard; downscale or no burnout options are PC programmable [3] POWER INPUT Linearization (T/C, RTD input): Standard tables stored in AC Power memory M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Cold junction compensation (T/C): CJC sensor (included) to 47 – 66 Hz) be attached to the input terminals DC Power Status indicator LED: Flashing patterns indicate different R: 24 V DC operating status of the transmitter. (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) Configurator connection: 2.5 dia. miniature jack; P: 110 V DC RS-232-C level (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) MODBUS COMMUNICATION [4] OPTIONS (multiple selections) Standard: Conforms to RS-485, EIA Standards & Approvlas (must be specified) Transmission distance: 500 meters max. /N: Without CE Baud rate: 38.4 kbps max. /CE: CE marking Communication: Half-duplex, asynchronous, no procedure Other Options Protocol: Modbus RTU blank: none Transmission media: Shielded twisted-pair cable /Q: Option other than the above (specify the specification) (CPEV-S 0.9 dia.) SPECIFICATIONS OF OPTION: Q (multiple selections) INPUT SPECIFICATIONS COATING (For the detail, refer to M-System's web site.) ■ DC Current: Shunt resistor attached to the input terminals /C01: Silicone coating (0.5 W) /C02: Polyurethane coating Operational range: 0 – 70 mA DC with 100 Ω, 0.5 W /C03: Rubber coating Input range: 0 – 50 mA DC TERMINAL SCREW MATERIAL Minimum span: 2 mA /S01: Stainless steel Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained. RELATED PRODUCTS If not specified, the input range is 4 – 20 mA DC. • JX configurator connection kit (model: JXCON) ■ DC Voltage For configuration JXCON is necessary. Operational range: -11.5 – +11.5 V DC Input range: -10 – +10 V DC Minimum span: 10 mV for S1; 100 mV for S2 GENERAL SPECIFICATIONS Offset: Lower range can be any specific value within the Construction: Plug-in input range provided that the minimum span is maintained. Connection: M3 screw terminals (torque 0.8 N·m) If not specified, the input range is shown below. Housing material: Flame-resistant resin (black) S1: 0 – 100 mV DC Isolation: Input to output to RS-485 to power S2: 1 – 5 V DC Overrange output: Approx. -15 to +115 % ■ Thermocouple (Negative current output is not provided.) For T/C types K, E, T, B, R, S or N, the accuracy in the Manual zero adjustments: -5 to +5 % temperature ranges near the lower limit may be out of the (factory setting: 0 %) described value. Consult M-System for more detail. Manual span adjustments: 95 to 105 % Input resistance: 1 MΩ min. (factory setting: 100 %) Burnout sensing: 45 nA ±10 % Programming: PC programmable features include: Offset: Lower range can be any specific value within the · T/C and RTD type and temp. range input range provided that the minimum span is maintained. · Input and output ranges If not specified, the input range is shown below. · Zero and span adjustments T1 PR : 0 – 1600°C · Simulated output T2 K : 0 – 1000°C · User's linearization table (max. 100 points, specified within T3 E : 0 – 500°C -15 – +115 % for both input and output) http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 2/7 MODEL: M2XUM T4 J: 0 – 500°C output range provided that the minimum span is T5 T: 0 – 300°C maintained. T6 B: 0 – 1800°C Load resistance: Output drive 1 mA max. T7 R: 0 – 1600°C (e.g. 1 – 5 V: 5000 Ω [5 V / 1 mA]) T8 S: 0 – 1600°C If not specified, the output range is shown below. T9 C (WRe 5 - 26) : 0 – 2000°C V1: 0 – 1 V DC TN N : 0 – 1000°C V2: 1 – 5 V DC TU U : 0 – 300°C TL L : 0 – 500°C INSTALLATION TP Platinel II : 0 – 1200°C Power Consumption ■ RTD: 2- or 3-wire RTD •AC Power input: Approx. 6 VA Maximum leadwire resistance: 200 Ω per wire (3 -wire) •DC power input: Approx. 3 W Sensing current: ≤ 1.0 mA Operating temperature: -30 to +60°C (-22 to +140°F) If not specified, the input range is shown below. Operating humidity: 30 to 90 %RH (non-condensing) R1: JPt 100 0 – 100°C Mounting: Surface or DIN rail R3: Pt 100 0 – 100°C Weight: 120 g (0.26 lbs) R4: Pt 100 0 – 100°C R5: Pt 50 Ω 0 – 200°C PERFORMANCE R6: Ni 508.4 Ω 0 – 100°C Accuracy: Input accuracy + output accuracy R7: Pt 1000 0 – 100°C Input accuracy (% of input range) R8: Ni 100 0 – 100°C Inversely proportional to span. R9: Cu 10 0 – 100°C (DC) -1 – +1 V : ±0.02 •Potentiometer: 100 Ω – 10 kΩ -10 – +10 V : ±0.02 Minimum span: 0 – 50 mA : ±0.02 (Range) 0 – 100 Ω : 2.5 Ω Except the input resistor error. 0 – 300 Ω : 3.0 Ω (T/C) (PR) : ±0.08 0 – 1000 Ω : 10 Ω K (CA) : ±0.02 0 – 10 kΩ : 10 Ω E (CRC) : ±0.02 Excitation: ≤ 0.5 V DC at 1000 Ω J (IC) : ±0.04 If not specified, the input range is 0 – 1000 Ω. T (CC) : ±0.06 B (RH) : ±0.12 OUTPUT SPECIFICATIONS R : ±0.08 ■ DC Current S : ±0.08 Operational range: 0 – 24 mA DC C (WRe 5 - 26) : ±0.04 Output range: 0 – 20 mA DC N : ±0.04 Minimum span: 1 mA U : ±0.04 Offset: Lower range can be any specific value within the L : ±0.04 output range provided that the minimum span is P (Platinel II) : ±0.04 maintained. (RTD) JPt 100 (JIS ’89) : ±0.04 Load resistance: Output drive 15 V max. Pt 100 (JIS ’89) : ±0.03 (e.g. 4 – 20 mA: 750 Ω [15 V / 20 mA]) Pt 100 (JIS ’97, IEC) : ±0.03 If not specified, the output range is 4 – 20 mA DC. Pt 50 Ω (JIS ’81) : ±0.04 ■ DC Voltage Ni 508.4 Ω : ±0.05 Code V1 (narrow spans) Pt 1000 : ±0.08 Operational range: -3 – +3 V DC Ni 100 : ±0.14 Output range: -2.5 – +2.5 V DC Cu 10 : ±0.6 Minimum span: 250 mV (Pot.) 0 – 100 Ω : ±0.08 Code V2 (wide spans) 0 – 300 Ω : ±0.04 Operational range: -11.5 – +11.5 V DC 0 – 1000 Ω : ±0.04 Output range: -10 – +10 V DC 0 – 10 kΩ : ±0.04 Minimum span: 1 V Output accuracy: ±0.02 % of output range Offset: Lower range can be any specific value within the http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 3/7 MODEL: M2XUM Inversely proportional to span. Cold junction compensation error: ±0.4°C or ±0.7°F (at 20°C ±10°C or 68°F ±18°F) Temp. coefficient (at -5 to +55°C [23 to 131°F] of I/O range) Input: ±0.016 %/°C (±0.009 %/°F) with current ±0.004 %/°C (±0.002 %/°F) with voltage ±0.004 %/°C (±0.002 %/°F) with T/C ±0.004 %/°C (±0.002 %/°F) with RTD ±0.004 %/°C (±0.002 %/°F) with Pot. Output: ±0.013 %/°C (±0.007 %/°F) Response time: ≤ 0.5 sec.(0 – 90 %) with current ≤ 0.5 sec.(0 – 90 %) with voltage ≤ 1.5 sec.(0 – 90 %) with T/C ≤ 0.9 sec.(0 – 90 %) with RTD ≤ 0.9 sec. (0 – 90 %) with Pot. Burnout response: ≤ 10 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to RS-485 to power to ground) CALCULATION EXAMPLES OF OVERALL ACCURACY [Example] Input Type -10 – +10 V, Input Range 1 – 5 V, Output Type 0 – 20 mA, Output Range 0 – 10 mA Max. Input Range (20 V) ÷ Span (4 V) × 0.02 % = 0.1 % Max. Output Range (20 mA) ÷ Span (10 mA) × 0.02 % = 0.04 % Overall accuracy = 0.1 + 0.04 = ±0.14 % STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 4/7 MODEL: M2XUM EXTERNAL VIEW � RIGHT SIDE VIEW � FRONT VIEW (with cover open) Address Setting Rotary SW Configurator Jack Input Range Selector Position H: code S2, Z1 Status Indicator LED Position L : other Zero/Span Selector Top: SPAN Middle: OFF Bottom: ZERO Modbus Term. Resistor : OFF UP/DOWN Switches : ON The front cover cannot be opened to 180 deg. when flush with neighboring units. Refer to the instruction manual for detailed procedures. DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 21.5 (.85) 7.3 (.29) 86.7 (3.41) 22 (.87) 116.7 (4.59) [4 (.16)] 29.5 (1.16) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) Use the input resistor (model: REM2) for a DC current input, and the CJC sensor (model: CJM) for a thermocouple input, both included in the package. INPUT RESISTOR (model: REM2) 3 2 1 6 5 4 9 8 7 11 10 http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 5/7 70.5 (2.78) 19 (.75) 59 (2.32) 4 (.16) 72 (2.83) Model Model Model MODEL: M2XUM CJC SENSOR (model: CJM) black red 2 3 2 1 1 6 5 4 9 8 7 11 10 SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM STATUS ADDRESS DC T/C RTD POT. INPUT RANGE ZERO/SPAN ext. wire SELECTOR SELECTOR Isolation + max. + + + Digital Output + A 3 1 7 – * Computation Driver R – Low Drift OUTPUT Amplifier – CJC B 2 2 UP/DOWN 8 – SWITCHES SENSOR & Burnout red (model: CJM) B 1 4 3 DA Isolation – min. ** black RS-485 COMM. 5 6 DB Interface INTERFACE CONFIGURATOR JACK 9 DG 10 U(+) POWER 11 V(–) Base Socket * Input shunt resistor attached for current input. **When the module is at the end of RS-485 transmission line, turn on the Modbus terminating resistor located behind the front cover, off when it is not. SYSTEM CONFIGURATION EXAMPLES RS-232C RS-485/RS-232C Converter (model: LK1) RS-485 Universal Transmitters (model: M2XUM) http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 6/7 14 (.55) MODEL: M2XUM MODBUS COMMUNICATION PARAMETERS Refer to the instruction manual for the details about Modbus communication. ■ COMMUNICATION PARAMETERS PARAMETER SPECIFICATIONS DEFAULT MODIFICATION Data Mode RTU RTU Not modifiable Baud Rate 9600/19200/38400 bps 38400 bps JXCON Software Parity None/Odd/Even Odd JXCON Software Bit Length 8 8 Not modifiable Stop Bit 1 1 Not modifiable Node Address 1 to 247 1 Hardware Rotary SW for 1 through 16, JXCON Software for 16 through 247 (Rotary SW set to 0). Floating Point Data Normal/Swapped Normal JXCON Software Physical Layer RS-485 RS-485 Not modifiable Specifications are subject to change without notice. http://www.m-system.co.jp/ M2XUM SPECIFICATIONS ES-5009 Rev.11 Page 7/7
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2XUM?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods