M-SYSTEMS M2XU
Specifications
Burnout (T/C, RTD and Pot.)
Upscale standard; downscale or no burnout options are PC programmable
Cold junction compensation (T/C)
CJC sensor (included) to be attached to the input terminals
Configurator connection
2.5 dia. miniature jack; RS-232C level
Connection
M3 screw terminals (torque 0.8 N·m)
Housing material
Flame-resistant resin (black)
Isolation
Input to output to power
Linearization (T/C, RTD input)
Standard tables stored in memory
Manual span adjustments
95 to 105 %
Manual zero adjustments
-5 to +5 %
Overrange output
Approx. -15 to +115 %
Status indicator LED
Flashing patterns indicate different operating status of the transmitter.
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
Model MODEL: M2XU Z1: Range 0 – 50 mA DC (Input resistance 100 Ω) Super-mini Signal Conditioners Mini-M Series Voltage S1: Range -1 – +1 V DC (Input resistance 1 MΩ min.) UNIVERSAL TRANSMITTER S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.) (PC programmable) Thermocouple Functions & Features T1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F) • Accepts direct inputs from various sensors and provides a T2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F) standard process signal T3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F) • I/O types and calibration ranges are fully programmable T4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F) via a PC T5: T (CC) (Usable range -270 to +400°C, -454 to +752°F) • Linearization up to 100 points can be programmed T6: B (RH) (Usable range 0 to 1820°C, 32 to 3308°F) for DC and potentiometer inputs T7: R (Usable range -50 to +1760°C, -58 to +3200°F) • Isolation between input – output – power T8: S (Usable range -50 to +1760°C, -58 to +3200°F) • CE marking T9: C(WRe 5-26) (Usable range 0 to 2315°C, 32 to 4199°F) • UL approval TN: N (Usable range -270 to +1300°C, -454 to +2372°F) TU: U (Usable range -200 to +400°C, -328 to +752°F) Typical Applications TL: L (Usable range -200 to +900°C, -328 to +1652°F) • Signal conversion between control room and field TP: Platinel Ⅱ(Usable range 0 to 1395°C, 32 to 2543°F) instrumentation with isolation T0: Specify (Please provide an emf table.) • Ideal for use as a fast solution, multifunctional spare part RTD (2- or 3-wire) 23 (.91) R1: JPt 100 (JIS'89) (Usable range: -200 to +500°C, -328 to +932°F) R3: Pt 100 (JIS'89) 76 (Usable range: -200 to +850°C, -328 to +1562°F) (2.99) R4: Pt 100 (JIS'97, IEC) (Usable range: -200 to +850°C, -328 to +1562°F) R5: Pt 50 Ω (JIS'81) 124 (4.88) (Usable range: -200 to +649 °C, -328 to +1200°F) mm (inch) R6: Ni 508.4 Ω (Usable range: -50 to +200°C, -58 to +392°F) R7: Pt 1000 MODEL: M2XU–[1][2]–[3][4] (Usable range: -200 to +200°C, -328 to +392°F) R8: Ni 100 (100 Ω @ 0℃) ORDERING INFORMATION (Usable range: -50 to +200°C, -58 to +392°F) • Code number: M2XU-[1][2]-[3][4] R9: Cu 10 (10 Ω @25°C) Specify a code from below for each [1] through [4]. (Usable range: -50 to +200°C, -58 to +392°F) (e.g. M2XU-00-R/CE/Q) R0: Specify (Please provide a resistance table.) • Specify the specification for option code /Q Potentiometer (e.g. /C01/S01) M: Total resistance 100 Ω – 10 kΩ Non-specified orders will be shipped at default factory [2] OUTPUT settings (M2XU-00: 4 – 20 mA input/4 – 20 mA output). 0: User-calibrated (Factory default: 4 – 20 mA DC) However, the power suffix code must be specified. If the unit is to be factory-calibrated to a specific If you specify full code numbers without specific calibration output type, please select from the following: ranges, default settings will be used. Current Z1: Range 0 – 20 mA DC [1] INPUT Voltage 0: User-calibrated (Factory default: 4 – 20 mA DC) V1: Range -2.5 – +2.5 V DC If the unit is to be factory-calibrated to a specific V2: Range -10 – +10 V DC input type, please select from the following: Current http://www.m-system.co.jp/ M2XU SPECIFICATIONS ES-5008 Rev.12 Page 1/6 MODEL: M2XU -15 – +115 % for both input and output) [3] POWER INPUT · User’s TC/RTD table AC Power Burnout (T/C, RTD and Pot.): Upscale standard; downscale M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, or no burnout options are PC programmable 47 – 66 Hz) Linearization (T/C, RTD input): Standard tables stored in (90 – 264 V for UL) memory DC Power Cold junction compensation (T/C): CJC sensor (included) to R: 24 V DC be attached to the input terminals (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) Status indicator LED: Flashing patterns indicate different P: 110 V DC operating status of the transmitter. (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) Configurator connection: 2.5 dia. miniature jack; (110 V ±10 % for UL) RS-232C level [4] OPTIONS (multiple selections) INPUT SPECIFICATIONS STANDARDS & APPROVALS (must be specified) • DC Current: Shunt resistor attached to the input terminals /N: Without CE or UL (0.5 W) /CE: CE marking Operational range: 0 – 70 mA DC with 100 Ω, 0.5 W /UL: UL approval (CE marking) Input range: 0 – 50 mA DC OTHER OPTIONS Minimum span: 2 mA blank: none Offset: Lower range can be any specific value within the /Q: Option other than the above (specify the specification) input range provided that the minimum span is maintained. (UL not available) If not specified, the input range is 4 – 20 mA DC. • DC Voltage SPECIFICATIONS OF OPTION: Q (multiple selections) Operational range: -11.5 – +11.5 V DC COATING (For the detail, refer to M-System's web site.) Input range: -10 – +10 V DC /C01: Silicone coating Minimum span: 10 mV for S1; 100 mV for S2 /C02: Polyurethane coating Offset: Lower range can be any specific value within the /C03: Rubber coating input range provided that the minimum span is maintained. TERMINAL SCREW MATERIAL If not specified, the input range is shown below. /S01: Stainless steel S1: 0 – 100 mV DC S2: 1 – 5 V DC • THERMOCOUPLE RELATED PRODUCTS For T/C types K, E, T, B, R, S or N, the accuracy in the • JX configurator connection kit (model: JXCON) temperature ranges near the lower limit may be out of the described value. Consult M-System for more detail. GENERAL SPECIFICATIONS Input resistance: 1 MΩ min. Construction: Plug-in Burnout sensing: 45 nA ±10 % Connection: M3 screw terminals (torque 0.8 N·m) Offset: Lower range can be any specific value within the Housing material: Flame-resistant resin (black) input range provided that the minimum span is maintained. Isolation: Input to output to power If not specified, the input range is shown below. Overrange output: Approx. -15 to +115 % T1 PR : 0 – 1600°C (Negative current output is not provided.) T2 K : 0 – 1000°C Manual zero adjustments: -5 to +5 % T3 E : 0 – 500°C (factory setting: 0 %) T4 J: 0 – 500°C Manual span adjustments: 95 to 105 % T5 T: 0 – 300°C (factory setting: 100 %) T6 B: 0 – 1800°C Programming: PC programmable features include: T7 R: 0 – 1600°C · T/C and RTD type and temp. range T8 S: 0 – 1600°C · Input and output ranges T9 C (WRe 5 - 26) : 0 – 2000°C · Zero and span adjustments TN N : 0 – 1000°C · Simulated output TU U : 0 – 300°C · User's linearization table (max. 100 points, specified within TL L : 0 – 500°C http://www.m-system.co.jp/ M2XU SPECIFICATIONS ES-5008 Rev.12 Page 2/6 MODEL: M2XU TP Platinel II : 0 – 1200°C INSTALLATION • RTD: 2- or 3-wire RTD Power Consumption Maximum leadwire resistance: 200 Ω per wire (3 -wire) •AC Power input: Approx. 6 VA Sensing current: ≤ 1.0 mA •DC Power input: Approx. 3 W If not specified, the input range is shown below. Operating temperature: -30 to +60°C (-22 to +140°F) R1: JPt 100 0 – 100°C Operating humidity: 30 to 90 %RH (non-condensing) R3: Pt 100 0 – 100°C Mounting: Surface or DIN rail R4: Pt 100 0 – 100°C Weight: 120 g (0.26 lbs) R5: Pt 50 Ω 0 – 200°C R6: Ni 508.4 Ω 0 – 100°C PERFORMANCE R7: Pt 1000 0 – 100°C Accuracy: Input accuracy + output accuracy R8: Ni 100 0 – 100°C Input accuracy (% of input range) R9: Cu 10 0 – 100°C Inversely proportional to span. • POTENTIOMETER: 100 Ω – 10 kΩ (DC) -1 – +1 V : ±0.02 Minimum span: -10 – +10 V : ±0.02 (Range) 0 – 100 Ω : 2.5 Ω 0 – 50 mA : ±0.02 0 – 300 Ω : 3.0 Ω Except the input resistor error. 0 – 1000 Ω : 10 Ω (T/C) (PR) : ±0.08 0 – 10 kΩ : 10 Ω K (CA) : ±0.02 Excitation: ≤ 0.5 V DC at 1000 Ω E (CRC) : ±0.02 If not specified, the input range is 0 – 1000 Ω. J (IC) : ±0.04 T (CC) : ±0.06 OUTPUT SPECIFICATIONS B (RH) : ±0.12 • DC Current R : ±0.08 Operational range: 0 – 24 mA DC S : ±0.08 Output range: 0 – 20 mA DC C (WRe 5 - 26) : ±0.04 Minimum span: 1 mA N : ±0.04 Offset: Lower range can be any specific value within the U : ±0.04 output range provided that the minimum span is L : ±0.04 maintained. P (Platinel II) : ±0.04 Load resistance: Output drive 15 V max. (RTD) JPt 100 (JIS ’89) : ±0.04 (e.g. 4 – 20 mA: 750 Ω [15 V / 20 mA]) Pt 100 (JIS ’89) : ±0.03 If not specified, the output range is 4 – 20 mA DC. Pt 100 (JIS ’97, IEC) : ±0.03 • DC VOLTAGE Pt 50 Ω (JIS ’81) : ±0.04 Code V1 (narrow spans) Ni 508.4 Ω : ±0.05 Operational range: -3 – +3 V DC Pt 1000 : ±0.08 Output range: -2.5 – +2.5 V DC Ni 100 : ±0.14 Minimum span: 250 mV Cu 10 : ±0.6 Code V2 (wide spans) (Pot.) 0 – 100 Ω : ±0.08 Operational range: -11.5 – +11.5 V DC 0 – 300 Ω : ±0.04 Output range: -10 – +10 V DC 0 – 1000 Ω : ±0.04 Minimum span: 1 V 0 – 10 kΩ : ±0.04 Offset: Lower range can be any specific value within the Output accuracy: ±0.02 % of output range output range provided that the minimum span is Inversely proportional to span. maintained. Cold junction compensation error: Load resistance: Output drive 1 mA max. ±0.4°C or ±0.7°F (at 20°C ±10°C or 68°F ±18°F) (e.g. 1 – 5 V: 5000 Ω [5 V / 1 mA]) Temp. coefficient If not specified, the output range is shown below. (at -5 to +55°C [23 to 131°F] of I/O range) V1: 0 – 1 V DC Input: ±0.016 %/°C (±0.009 %/°F) with current V2: 1 – 5 V DC ±0.004 %/°C (±0.002 %/°F) with voltage ±0.004 %/°C (±0.002 %/°F) with T/C ±0.004 %/°C (±0.002 %/°F) with RTD http://www.m-system.co.jp/ M2XU SPECIFICATIONS ES-5008 Rev.12 Page 3/6 MODEL: M2XU ±0.004 %/°C (±0.002 %/°F) with Pot. Output: ±0.013 %/°C (±0.007 %/°F) Response time: ≤ 0.5 sec.(0 – 90 %) with current ≤ 0.5 sec.(0 – 90 %) with voltage ≤ 1.5 sec.(0 – 90 %) with T/C ≤ 0.9 sec.(0 – 90 %) with RTD ≤ 0.9 sec. (0 – 90 %) with Pot. Burnout response: ≤ 10 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) CALCULATION EXAMPLES OF OVERALL ACCURACY [Example] Input Type -10 – +10 V, Input Range 1 – 5 V, Output Type 0 – 20 mA, Output Range 0 – 10 mA Max. Input Range (20 V) / Span (4 V) × 0.02 % = 0.1 % Max. Output Range (20 mA) / Span (10 mA) × 0.02 % = 0.04 % Overall accuracy = 0.1 + 0.04 = ±0.14 % STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EN 61000-6-4 (EMI) EN 61000-6-2 (EMS) Low Voltage Directive (2006/95/EC) EN 61010-1 Installation Category II Pollution Degree 2 Max. operating voltage 300 V Input or output to power: Reinforced insulation Input to output: Basic insulation Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (UL 1604, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) EXTERNAL VIEW � FRONT VIEW (with cover open) � RIGHT SIDE VIEW Configurator Jack Input Range Selector Status Indicator LED Position H: code S2, Z1 Position L : other Zero/Span Selector Top: SPAN Middle: OFF Bottom: ZERO UP/DOWN Switches The front cover cannot be opened to 180 deg. when flush with neighboring units. http://www.m-system.co.jp/ M2XU SPECIFICATIONS ES-5008 Rev.12 Page 4/6 MODEL: M2XU Refer to the instruction manual for detailed procedures. DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 7.3 (.29) 86.7 (3.41) 15 (.59) 116.7 (4.59) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) Use the input resistor (model: REM2) for a DC current input, and the CJC sensor (model: CJM) for a thermocouple input, both included in the package. INPUT RESISTOR CJC SENSOR (model: REM2) (model: CJM) black red 4 1 4 1 1 8 5 8 5 12 9 12 9 14 13 14 13 SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM STATUS DC T/C RTD POT. INPUT RANGE ZERO/SPAN ext. wire SELECTOR SELECTOR Isolation + max. + + + Digital Output + A 3 1 9 – * Computation Driver R – Low Drift OUTPUT Amplifier – CJC B 2 4 UP/DOWN 12 – SWITCHES SENSOR & Burnout red (model: CJM) B 1 5 13 U(+) – min. POWER black 8 14 V(–) CONFIGURATOR JACK Base Socket *Input shunt resistor attached for current input. http://www.m-system.co.jp/ M2XU SPECIFICATIONS ES-5008 Rev.12 Page 5/6 70.5 (2.78) 19 (.75) 14 (.55) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2XU Specifications are subject to change without notice. http://www.m-system.co.jp/ M2XU SPECIFICATIONS ES-5008 Rev.12 Page 6/6
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2XU?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods