M-SYSTEMS M2XR2
Specifications
Burnout
Upscale standard; downscale or no burnout optional by programming
Configurator connection
2.5 dia. miniature jack; RS-232-C level
Connection
M3 screw terminals (torque 0.8 N·m)
Construction
Plug-in
Housing material
Flame-resistant resin (black)
Isolation
Input to output to power
Linearization
Standard
Manual span adjustments
95 to 105 % (factory setting
Manual zero adjustments
-5 to +5 % (factory setting
Over-range output
Approx. -15 to +115 % (Negative current output is not provided.)
Programming
Downloaded from PC; input type and range, output range, zero and span, simulating output, etc.
Status indicator LED
Flashing patterns indicate different operating status of the transmitter.
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
Model MODEL: M2XR2 0: Specify (Please provide a resistance table.) Super-mini Signal Conditioners Mini-M Series (Configurator software is used to change input type and temperature range.) RTD TRANSMITTER (PC programmable) [2] OUTPUT Functions & Features Current • Accepts direct input from an RTD and provides a standard Z1: Range 0 – 20 mA DC process signal Voltage • PC programmable V1: Range -2.5 – +2.5 V DC • User’s temperature table can be used V2: Range -10 – +10 V DC • Leadwire resistance compensation (Configurator software is used to change output over the • CE marking described range of the selected suffix code. For changing • UL approval out of this range, set the Output Range Selectors inside the unit before software adjustment.) Typical Applications • Long distance transmission between the RTD and the transmitter [3] POWER INPUT • Combination with intrinsic safety barriers AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 23 (.91) 47 – 66 Hz) (90 – 264 V for UL) DC Power 76 R: 24 V DC (2.99) (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) 124 (4.88) (110 V ±10 % for UL) mm (inch) [4] OPTIONS (multiple selections) MODEL: M2XR2–[1][2]–[3][4] BURNOUT blank: Upscale burnout /BL: Downscale burnout ORDERING INFORMATION (UL not available) • Code number: M2XR2-[1][2]-[3][4] /BN: No burnout Specify a code from below for each [1] through [4]. (UL not available) (e.g. M2XR2-4Z1-R/BL/CE/Q) STANDARDS & APPROVALS (must be specified) Input Code 4: Pt 100 (JIS ’97, IEC) setting will be used if the /N: Without CE or UL input code is not specified. /CE: CE marking • Temperature range (e.g. 0 – 500°C) /UL: UL approval (CE marking) • Output range (e.g. 4 – 20 mA DC) OTHER OPTIONS • Specify the specification for option code /Q blank: none (e.g. /C01/S01) /Q: Option other than the above (specify the specification) (UL not available) [1] INPUT RTD (2- or 3-wire) 1: JPt 100 (JIS'89) SPECIFICATIONS OF OPTION: Q (multiple selections) 3: Pt 100 (JIS'89) COATING (For the detail, refer to M-System's web site.) 4: Pt 100 (JIS'97, IEC) /C01: Silicone coating 5: Pt 50 Ω (JIS'81) /C02: Polyurethane coating 6: Ni 508.4 Ω /C03: Rubber coating 7: Pt 1000 TERMINAL SCREW MATERIAL 8: Ni 100 /S01: Stainless steel 9: Cu 10 @25°C http://www.m-system.co.jp/ M2XR2 SPECIFICATIONS ES-5087 Rev.5 Page 1/4 MODEL: M2XR2 • DC VOLTAGE RELATED PRODUCTS Code V1 (narrow spans) • JX configurator connection kit (model: JXCON) Operational range: -3 – +3 V DC Output range: -2.5 – +2.5 V DC GENERAL SPECIFICATIONS Minimum span: 250 mV Construction: Plug-in Code V2 (wide spans) Connection: M3 screw terminals (torque 0.8 N·m) Operational range: -11.5 – +11.5 V DC Housing material: Flame-resistant resin (black) Output range: -10 – +10 V DC Isolation: Input to output to power Minimum span: 1 V Overrange output: Approx. -15 to +115 % Offset: Lower range can be any specific value within the (Negative current output is not provided.) output range provided that the minimum span is Manual zero adjustments: -5 to +5 % maintained. (factory setting: 0 %) Load resistance: Output drive 1 mA max. Manual span adjustments: 95 to 105 % (e.g. 1 – 5 V: 5000 Ω [5 V / 1 mA]) (factory setting: 100 %) If not specified, the output range is shown below. Programming: Downloaded from PC; input type and range, V1: 0 – 1 V DC output range, zero and span, simulating output, etc. V2: 1 – 5 V DC Burnout: Upscale standard; downscale or no burnout optional by programming INSTALLATION Linearization: Standard Power Consumption Status indicator LED: Flashing patterns indicate different •AC Power input: operating status of the transmitter. Approx. 3 VA at 100 V Configurator connection: 2.5 dia. miniature jack; Approx. 4 VA at 200 V RS-232-C level Approx. 5 VA at 264 V •DC power input: Approx. 2 W INPUT SPECIFICATIONS Operating temperature: -30 to +60°C (-22 to +140°F) ■ RTD: 2- or 3-wire RTD Operating humidity: 30 to 90 %RH (non-condensing) Maximum leadwire resistance: 20 Ω per wire Mounting: Surface or DIN rail Sensing current: ≤ 1.0 mA Weight: 120 g (0.26 lbs) Temperature range: See Table 1. PERFORMANCE If not specified, the input range is shown below. Accuracy: Table 1 value or ±0.1 % of span, whichever is 1: JPt 100 (JIS '89) 0 – 100°C greater. Add 0.2 % when the output span equals 1/10 or 3: Pt 100 (JIS '89) 0 – 100°C narrower of the max. span. 4: Pt 100 (JIS '97, IEC) 0 – 100°C Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. span 5: Pt 50 Ω (JIS '81) 0 – 200°C at -5 to +55°C [23 to 131°F] 6:Ni 508.4 Ω 0 – 100°C Response time: ≤ 0.9 sec. (0 – 90 %) 7: Pt 1000 0 – 100°C Burnout response: ≤ 10 sec. 8: Ni 100 0 – 100°C Line voltage effect: ±0.1 % over voltage range 9 :Cu 10 @25°C 0 – 100°C Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output OUTPUT SPECIFICATIONS to power to ground) • DC Current Operational range: 0 – 24 mA DC CALCULATION EXAMPLES OF OVERALL ACCURACY Output range: 0 – 20 mA DC [Example 1] Minimum span: 1 mA Input: Pt 100 (JIS ’97, IEC), 0 – 500°C Offset: Lower range can be any specific value within the Output: 4 – 20 mA DC output range provided that the minimum span is 1) ±0.15°C referred from Table 1, is converted into % by maintained. the following equation: 0.15°C / 500°C = 0.03%. Load resistance: Output drive 15 V max. 2) 0.03% ≤ 0.1% of span. ➠ 0.1% is selected. (e.g. 4 – 20 mA: 750 Ω [15 V / 20 mA]) 3) Output span 16 mA (= 20 mA – 4 mA) If not specified, the output range is 4 – 20 mA DC. http://www.m-system.co.jp/ M2XR2 SPECIFICATIONS ES-5087 Rev.5 Page 2/4 MODEL: M2XR2 Max. span 20 mA Output span ≥ 1/10 of max. span ➠ No need of adding 0.2%. 4) Overall accuracy equals ±0.1% of span [Example 2] Input: Pt 100 (JIS ’97, IEC), 0 – 100°C Output: 2.0 – 2.5 V DC 1) ±0.15°C referred from Table 1, is converted into % by the following equation: 0.15°C / 100°C = 0.15%. 2) 0.15% ≥ 0.1% of span. ➠ 0.15% is selected. 3) Output span 0.5 V (= 2.5 V – 2.0 V) Max. span 5 V Output span ≤ 1/10 of max. span ➠ Add 0.2%. 4) Overall accuracy equals ±0.35% of span (0.15 + 0.2) Table 1. MIN. RTD USABLE RANGE ACCURACY SPAN °C 20 -200 to +500 ±0.15 JPt 100 (JISʼ89) °F 36 -328 to +932 ±0.27 °C 20 -200 to +850 ±0.15 Pt 100 (JISʼ89) -328 to +1562 °F 36 ±0.27 20 -200 to +850 °C ±0.15 Pt 100 (JISʼ97, IEC) °F 36 -328 to +1562 ±0.27 -200 to +649 °C 20 ±0.15 Pt 50Ω (JISʼ81) °F 36 -328 to +1200 ±0.27 20 -50 to +200 °C ±0.15 Ni 508.4Ω 36 -58 to +392 °F ±0.27 20 -200 to +200 ±0.15 °C Pt 1000Ω 36 -328 to +392 ±0.27 °F °C 20 -50 to +200 ±0.15 Ni 100 °F 36 -58 to +392 ±0.27 °C 20 -50 to +200 ±0.50 Cu 10 (@25°C) °F 36 ±0.90 -58 to +392 STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EN 61000-6-4 (EMI) EN 61000-6-2 (EMS) Low Voltage Directive (2006/95/EC) EN 61010-1 Installation Category II Pollution Degree 2 Max. operating voltage 300 V Input or output to power: Reinforced insulation Input to output: Basic insulation Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (UL 1604, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) http://www.m-system.co.jp/ M2XR2 SPECIFICATIONS ES-5087 Rev.5 Page 3/4 MODEL: M2XR2 EXTERNAL VIEW � FRONT VIEW (with cover open) � LEFT SIDE VIEW (with cover removed) ATT [e.g.] V Configurator Jack Output code V1 SW3 I SW6 SW2 Status Indicator LED Zero/Span Selector Top: SPAN V I Middle: OFF Bottom: ZERO SW7 SW4 UP/DOWN Switches Output Range Selectors The front cover cannot be turned open by 180 deg. when there is no extra space between units. Refer to the instruction manual for detailed procedures. DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 7.3 (.29) 86.7 (3.41) 15 (.59) 116.7 (4.59) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM STATUS ZERO/SPAN OUTPUT RANGE SELECTOR SELECTORS Isolation RTD Digital Output A + 1 9 Computation Driver Low Drift OUTPUT Amplifier UP/DOWN – B 4 12 SWITCHES & Burnout U(+) B 5 13 POWER V(–) 8 14 CONFIGURATOR JACK Base Socket Specifications are subject to change without notice. http://www.m-system.co.jp/ M2XR2 SPECIFICATIONS ES-5087 Rev.5 Page 4/4 70.5 (2.78) 59 (2.32) 1 O 4 (.16) 72 (2.83) 2 N 3 4 1 O 2 N 3 4 5 6 7 8
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2XR2?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods