Industrial Trading chervon right Manufacturers chervon right M chervon right M-SYSTEMS chervon right M2XPA3
About product Specifications Features Datasheet FAQ

M-SYSTEMS M2XPA3

Image of M-SYSTEMS M2XPA3

Description

M-Systems M2XPA3 Mini-M Series Super-mini Signal Conditioner; Frequency Transmitter (PC Programmable)

Part Number

M2XPA3

Price

Request Quote

Manufacturer

M-SYSTEMS

Lead Time

Request Quote

Category

Signal Conditioning

Specifications

Accuracy

Input accuracy + output accuracy

Configuration

Via PC Configurator Software (model-JXCON) on the Windows PC connected to the front jack

Configurator connection

2.5 dia. miniature jack; RS-232-C level

Connection

M3 screw terminals (torque 0.8 N•m)

Construction

Plug-in

Dielectric Strength

2000 V AC @1 minute (input to output to power to ground)

Excitation adjustment

4 V, 8 V or 12 V DC

Housing Material

Flame-resistant resin (black)

Input accuracy

±0.03 % of the selected freq. range

Isolation

Input to output to power

Line Voltage Effect

±0.1 % over voltage range

Output accuracy

±0.03 % of the selected output range

Over-range output

Approx. -15 to +115 % at 1 – 5 V

Response Time

0.5 sec. + 1 pulse cycle (0 – 90 %)

Span adjustment

95 to 105 % (front)

Status indicator LED

Flashing patterns indicate different operating status of the transmitter

TEMP COEFFICIENT

±0.015 %/°C (±0.008 %/°F) of I/O range at -5 to +55°C [23 to 131°F]

Zero adjustment

-5 to +5 % (front)

Features

Datasheet

pdf file

M2XPA3-666707390.pdf

117 KiB

Extracted Text

Model MODEL: M2XPA3 Detecting level: 2 V Super-mini Signal Conditioners Mini-M Series Frequency range: 0 – 200 kHz Input zero frequency: 0 Hz FREQUENCY TRANSMITTER Input span frequency: 100 kHz (PC programmable) Linearization: No linearization Functions & Features Low-end cutout: 0 % (No cutout) • Converts the output from a pulse-type transducer into a Moving averaging samples: 1 standard process signal Sensor excitation: 12 V DC / 20 mA • PC programmable Output type: DC current • Sensor excitation Output 0%: 4mA • Direct RS-422 input Output 100%: 20mA • CE marking • UL approval [1] INPUT A1: Open collector Typical Applications A2: Mechanical contact • Positive displacement flowmeters, turbine flowmeters and B: Voltage pulse vortex flowmeters G: Two-wire current pulse • Measuring rotation speed of a machine generating dry J: RS-422 line driver pulse contact signals Configurator software is used to change the frequency range. The input type can be switched to other than the one 23 (.91) of the selected suffix code by selecting the input type selectors inside the unit before software adjustment. 76 (2.99) [2] EXCITATION 2: 4 V DC / 20 mA 3: 8 V DC / 20 mA 124 (4.88) 4: 12 V DC / 20 mA mm (inch) Configurator software is used to change the excitation value. MODEL: M2XPA3-[1][2][3]-[4][5] [3] OUTPUT Current ORDERING INFORMATION Z1: Range 0 – 20 mA DC • Code number: M2XPA3-[1][2][3]-[4][5] Voltage Specify a code from below for each [1] through [5]. V1: Range -2.5 – +2.5 V DC (e.g. M2XPA3-A14Z1-R/CE/Q) V2: Range -10 – +10 V DC • Specify the specification for option code /Q (Configurator software is used to adjust the output range (e.g. /C01/S01) and to change the output over the described range of the • Non-specified orders will be shipped at the default factory selected suffix code.) settings as shown in below. However, a power suffix code must be specified. If you specify a full code number without specific calibration [4] POWER INPUT ranges, the input and output ranges are factory set to the AC Power default range. M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Use Ordering Information Sheet (No. ESU-5104). 47 – 66 Hz) (90 – 264 V for UL) [Factory default setting] DC Power PARAMETER: DEFAULT R: 24 V DC Input type: Open collector (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) Input amplitude: ---- P: 110 V DC Pulse sensing: DC coupled (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) Noise filter: None http://www.m-system.co.jp/ M2XPA3 SPECIFICATIONS ES-5104 Rev.6 Page 1/5 MODEL: M2XPA3 (110 V ±10 % for UL) Low-end cutout: 0 – 115 % programmable; No cutout with 0 % setting; hysteresis fixed at 1 % (factory set to: No cutout) [5] OPTIONS (multiple selections) Standards & Approvlas (must be specified) /N: Without CE or UL INPUT SPECIFICATIONS /CE: CE marking Excitation: Shortcircuit protection; 30 mA max. at /UL: UL approval, CE marking shortcircuit Other Options Frequency ranges: blank: none 0 – 10 mHz, 0 – 100 mHz, 0 – 1 Hz, 0 – 10 Hz, 0 – 100 Hz, /Q: Option other than the above (specify the specification) 0 – 1 kHz, 0 – 10 kHz, 0 – 200 kHz (UL not available) (up to 10 Hz for mechanical contact) Minimum pulse width time requirement: 2.5 μsec. for both ON and OFF. (50 msec. for mechanical contact) SPECIFICATIONS OF OPTION: Q (multiple selections) Minimum span: 10 % of the selected frequency range COATING (For the detail, refer to M-System's web site.) (5 % of the selected frequency range when the range is /C01: Silicone coating 0 – 200 kHz.) /C02: Polyurethane coating Noise filter: See table 2 /C03: Rubber coating Choose the noise filter type appropriate for the selected TERMINAL SCREW MATERIAL frequency range to ensure the described accuracy. /S01: Stainless steel ■ Open Collector & Mechanical Contact Input requirements RELATED PRODUCTS EXC SENSING OFF ON • JX configurator connection kit (model: JXCON) 4V Approx. 3V/0.7mA ≥2kΩ/1V ≤200Ω/0.2V 8V Approx. 6V/1.5mA ≥4kΩ/3V ≤600Ω/1V 12V Approx. 9V/2.3mA ≥2kΩ/3V ≤400Ω/1V GENERAL SPECIFICATIONS Detecting level: Construction: Plug-in 0.6 V (4 V excitation) Connection: M3 screw terminals (torque 0.8 N·m) 2 V (8 V / 12 V excitation) Housing material: Flame-resistant resin (black) If not specified, the input range is shown below. Isolation: Input to output to power A1 Open collector: 0 – 100 kHz Overrange output: Approx. -15 to +115 % at 1 – 5 V A2 Mechanical contact: 0 – 10 Hz Zero adjustment: -5 to +5 % (front) ■ Voltage Pulse Span adjustment: 95 to 105 % (front) Waveform: Square or sine Configuration: Via PC Configurator Software (model: JXCON) Input impedance: ≥ 10 kΩ on the Windows PC connected to the front jack. Input amplitude: Min. 0.1 Vp-p, max. 100 Vp-p Programmable features include: Max. voltage between input terminals: See table 1. · I/O type and range Detecting levels: -2 – +4 V (internal detecting voltage) · Detecting level If not specified, the input range is 0 – 100 kHz. · Sensor excitation ■ Two-wire Current Pulse · Zero and span adjustments Input resistance: Receiving resistor 100 Ω · Low-end cutout Input range: 0 – 25 mA · Linearization Detecting levels: -2 – +4 V (internal detecting voltage) · Sample number for the moving average If not specified, the input range is 0 – 100 kHz. DIP switch settings: ■ RS-422 Line Driver Pulse • Input Type Receiver: Conforms to RS-422 • Pulse Sensing (Capacitor coupled, DC coupled) If not specified, the input range is 0 – 100 kHz. • Noise Filter (High, Low, None) Status indicator LED: Flashing patterns indicate different operating status of the transmitter. Excitation adjustment: 4 V, 8 V or 12 V DC Configurator connection: 2.5 dia. miniature jack; RS-232-C level http://www.m-system.co.jp/ M2XPA3 SPECIFICATIONS ES-5104 Rev.6 Page 2/5 MODEL: M2XPA3 ■ VOLTAGE PULSE Conformance range: -3 – +3 V DC Volts Output range: -2.5 – +2.5 V DC 100V max. Minimum span: 250 mV Code V2 (wide spans) Amplitude Conformance range: -11.5 – +11.5 V DC Vinp-p Output range: -10 – +10 V DC DC Offset Minimum span: 1 V t Offset: Lower range can be any specific value within the [Table 1] output range provided that the minimum span is PULSE MAX. VOLTAGE AT SENSITIVITY maintained. AMPLITUDE INPUT TERMINALS SCALE Load resistance: Output drive 1 mA max. 50 – 100 Vp-p 100 V* 1/20 (e.g. 1 – 5 V: 5000 Ω [5 V / 1 mA]) 25 – 50 Vp-p 50 V 1/10 If not specified, the output range is shown below. 10 – 25 Vp-p 25 V 1/5 5 – 10 Vp-p 10 V 1/2 V1: 0 – 1 V DC 1 – 5 Vp-p 5 V 1 V2: 1 – 5 V DC 0.5 – 1 Vp-p 1 V 5 0.1 – 0.5 Vp-p** 0.5 V 10 Open collector INSTALLATION Mechanical contact ---- 1 Power Consumption 2-wire current pulse •AC: *Limited to ≤70V for CE conformance or UL approval. Approx. 4 VA at 100 V **Input frequency ≤50 kHz Approx. 5 VA at 200 V A specific sensitivity scale is applied according to the pulse Approx. 6 VA at 264 V amplitude by setting up the DIP switch and PC Configurator Software (model: JXCON). The scaled input voltage is then •DC: Approx. 2 W compared to the detecting level at -2.00 through +4.00V. Operating temperature: -5 to +55°C (23 to 131°F) With DC coupling, the scaled maximum input voltage level Operating humidity: 30 to 90 %RH (non-condensing) voltage must be higher than and the scaled minimum input voltage level must be lower than the detecting level so that Mounting: Surface or DIN rail the pulse state is accurately detected. Weight: 150 g (0.33 lbs) [Table 2] FREQUENCY RANGE NOISE FILTER 0 – 10 mHz High PERFORMANCE 0 – 100 mHz High Accuracy: Input accuracy + output accuracy 0 – 1 Hz Low Inversely proportional to the span. 0 – 10 Hz Low Input accuracy: ±0.03 % of the selected freq. range 0 – 100 Hz Low (The input span 100 kHz is used for calculation with 0 – 200 0 – 1 kHz Low kHz range. The input accuracy is fixed at ±0.03 % when 0 – 10 kHz None [Frequency range / Input span] equals 1 or less.) 0 – 200 kHz None Choose the noise filter type appropriate for the selected Output accuracy: ±0.03 % of the selected output range frequency range to ensure the described accuracy. See CALCULATION EXAMPLES OF OVERALL ACCURACY. Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of I/O range at -5 to +55°C [23 to 131°F] OUTPUT SPECIFICATIONS Response time: 0.5 sec. + 1 pulse cycle (0 – 90 %) ■ DC Current Line voltage effect: ±0.1 % over voltage range Output range: 0 – 20 mA DC Insulation resistance: ≥ 100 MΩ with 500 V DC Conformance range: 0 – 24 mA DC Dielectric strength: 2000 V AC @1 minute (input to output Minimum span: 1 mA to power to ground) Offset: Lower range can be any specific value within the output range provided that the minimum span is CALCULATION EXAMPLES OF OVERALL ACCURACY maintained. [Example] Open collector input, 0 – 50 kHz; 1 – 5 V output. Load resistance: Output drive 12 V max. Selected freq. range (100 kHz) ÷ Input span (50 kHz)× (e.g. 4 – 20 mA: 600 Ω [12 V / 20 mA]) Accuracy (0.03 %)= 0.06 % (Input accuracy) If not specified, the output range is 4 – 20 mA DC. Selected output range (20 V) ÷ Output span (4 V) × ■ DC Voltage Accuracy (0.03 %)= 0.15 % (Output accuracy) Code V1 (narrow spans) http://www.m-system.co.jp/ M2XPA3 SPECIFICATIONS ES-5104 Rev.6 Page 3/5 MODEL: M2XPA3 Overall accuracy = 0.06 + 0.15 = ±0.21 % STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (ANSI/ISA-12.12.01:2007, CAN/CSA-C22.2 No.213:1987) UL/C-UL general safety requirements (UL 61010-1:2008, CAN/CSA-C22.2 No.61010-1:1992) EXTERNAL VIEW � FRONT VIEW (with cover open) � LEFT SIDE VIEW (with cover removed) Configurator Jack Selector SW OFF ON Status Indictor LED 1 2 3 Zero/Span Selector 4 SW4 Top: SPAN Middle: OFF Bottom: ZERO UP/DOWN Switches L L L H H H The front cover cannot be opened to 180 deg. when flush with neighboring units. SW1 SW2 SW3 Refer to the instruction manual for detailed procedures. DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 7.3 (.29) 86.7 (3.41) 15 (.59) 116.7 (4.59) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. http://www.m-system.co.jp/ M2XPA3 SPECIFICATIONS ES-5104 Rev.6 Page 4/5 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2XPA3 SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM STATUS INPUT TYPE MON. ZERO/SPAN SELECTOR SELECTOR Isolation Digital Output 1 9 + Computation Driver Waveform OUTPUT Shaper 4 12 – 1 UP/DOWN INPUT * SWITCHES 5 13 U(+) Excitation POWER Supply 8 14 V(–) CONFIGURATOR JACK Base Socket *1. Input Connection Examples � Open Collector � Voltage Pulse � RS-422 Line Driver Pulse or Mechanical Contact + + + 1 1 1 INPUT – – 4 4 4 – – – Vsns Vsns PWR PWR + + + 5 5 5 5kΩ PWR Vsns 8 – � 2-Wire Current Pulse • Built-in Excitation • External DC Supply DC SUPPLY 100Ω 100Ω 4 – 4 Vsns + Vsns + 5 5 2-WIRE + 2-WIRE PICK-UP PICK-UP – 8 – 8 EXPLANATIONS OF TERMS Low-end cutout: The function where the output signal is forced to 0% below the setpoint input. Hysteresis is fixed at 1%. [Example] Input zero frequency 0 Hz Input span frequency 1 kHz Low-end cutout 10 % OUTPUT INPUT 0% 10% 11% 100% 0 Hz 100 Hz 110 Hz 1 kHz Specifications are subject to change without notice. http://www.m-system.co.jp/ M2XPA3 SPECIFICATIONS ES-5104 Rev.6 Page 5/5

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the M2XPA3?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

M-Systems 20VS1A Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (High Speed Response, 3-...

product

M-Systems 20VS1B Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (input isolation)

product

M-Systems 20VS2-01 Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (3-Port Isolation)

product

M-Systems 20VS2-02 Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (3-Port Isolation)

product

M-Systems 20VS2-1 Hybrid Isolation Amplifiers 20 Series Isolation Amplifier (input isolation)

product

M-Systems 20VS2-2 Hybrid Isolation Amplifiers 20 Series Isolation Amplifier (output isolation)