M-SYSTEMS M2SP
Specifications
Accuracy
±0.1 % (output 10 – 100 %)
Connection
M3 screw terminals (torque 0.8 N-m)
Construction
Plug-in
DC Current
0 – 20 mA DC
DC VOLTAGE
0 – 12 V DC
Dielectric strength
2000 V AC @1 minute (input to output to power to ground)
Dry Contact
Mechanical contact or open collector
Excitation
12 V DC @30 mA; short-circuit protection
FREQUENCY RANGE
0 – 50 Hz through 10 kHz
Housing Material
Flame-resistant resin (black)
Input Filter
Provided with input range
Input impedance
10 kO min
Input pulse sensing
DC coupled; detecting pulse rise
Isolation
Input to output to power
Line voltage effect
±0.1 % over voltage range
Load resistance
Output drive 1 mA max.; at
Low-end cutout
2 to 5 %
Minimum span
5 mV
Offset
Max. 1.5 times span
Over-range output
0 to 120 % at 1 – 5 V
Pulse width time requirement
20 µsec. min. for high and low levels
Ripple
0.2 %p-p max. with input
Sensing
Approx. 12 V DC @3 mA
Span adjustment
95 to 105 % (front)
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Voltage Pulse
Square or sine waveforms
Zero adjustment
-5 to +5 % (front)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
Model ZERO SPAN MODEL: M2SP 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) Super-mini Signal Conditioners Mini-M Series 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) LOW FREQUENCY TRANSMITTER 4: 0 – 10 V DC (Load resistance 10 kΩ min.) (50 Hz minimum) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) Functions & Features 6: 1 – 5 V DC (Load resistance 5000 Ω min.) • Converts the output from a pulse-type transducer 0: Specify voltage (See OUTPUT SPECIFICATIONS) into a standard process signal • CE marking [3] POWER INPUT • UL approval AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, Typical Applications 47 – 66 Hz) • Positive displacement flowmeters, turbine flowmeters and (Select ‘/N’ for ‘Standards & Approvals’ code.) vortex flowmeters M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, • Proximity switches 47 – 66 Hz) (90 – 264 V for UL) 23 (.91) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) 76 (2.99) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) 124 P: 110 V DC (4.88) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) mm (inch) (110 V ±10 % for UL) MODEL: M2SP-[1][2]-[3][4] [4] OPTIONS (multiple selections) LOW-END CUTOUT ORDERING INFORMATION blank: With • Code number: M2SP-[1][2]-[3][4] /DN: Without Specify a code from below for each [1] through [4]. (Select ‘/N’ for ‘Standards & Approvals’ code.) (e.g. M2SP-1A-M2/CE/Q) STANDARDS & APPROVALS (must be specified) • Input frequency range (e.g. 0 – 10 kHz) /N: Without CE or UL • Specify the specification for option code /Q /CE: CE marking (e.g. /C01/S01) /UL: UL approval (CE marking) OTHER OPTIONS blank: none [1] INPUT /Q: Option other than the above (specify the specification) 1: Dry contact (UL not available) 2: Voltage pulse SPECIFICATIONS OF OPTION: Q (multiple selections) [2] OUTPUT COATING (For the detail, refer to M-System's web site.) Current /C01: Silicone coating A: 4 – 20 mA DC (Load resistance 750 Ω max.) /C02: Polyurethane coating B: 2 – 10 mA DC (Load resistance 1500 Ω max.) /C03: Rubber coating C: 1 – 5 mA DC (Load resistance 3000 Ω max.) TERMINAL SCREW MATERIAL D: 0 – 20 mA DC (Load resistance 750 Ω max.) /S01: Stainless steel E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage http://www.m-system.co.jp/ M2SP SPECIFICATIONS ES-5056 Rev.13 Page 1/3 MODEL: M2SP GENERAL SPECIFICATIONS PERFORMANCE in percentage of span Construction: Plug-in Accuracy: ±0.1 % (output 10 – 100 %) Connection: M3 screw terminals (torque 0.8 N·m) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Housing material: Flame-resistant resin (black) Response time: (0 – 90%) Isolation: Input to output to power Approx. 1.8 sec. with 0 – 50 Hz Overrange output: 0 to 120 % at 1 – 5 V Approx. 0.7 sec. with 0 – 100 Hz Zero adjustment: -5 to +5 % (front) Approx. 0.5 sec. with 0 – 500 Hz Span adjustment: 95 to 105 % (front) Approx. 0.5 sec. with 0 – 10 kHz Input pulse sensing: DC coupled; detecting pulse rise Ripple: 0.2 %p-p max. with input ≥ 10 % Input filter: Provided with input range <100 Hz Line voltage effect: ±0.1 % over voltage range (time constant approx. 1 msec.) Insulation resistance: ≥ 100 MΩ with 500 V DC Low-end cutout: 2 to 5 % Dielectric strength: 2000 V AC @1 minute (input to output (For /DN option, the output signal may fluctuate when the to power to ground) input signal is less than 5 %.) STANDARDS & APPROVALS INPUT SPECIFICATIONS CE conformity: Excitation: 12 V DC @30 mA; shortcircuit protection EMC Directive (2004/108/EC) Frequency range: 0 – 50 Hz through 10 kHz EN 61000-6-4 (EMI) • Dry Contact: Mechanical contact or open collector EN 61000-6-2 (EMS) Pulse width time requirement: 20 μsec. min. for ON and OFF Low Voltage Directive (2006/95/EC) Sensing: Approx. 12 V DC @3 mA EN 61010-1 ON/OFF level: ≤ 200 Ω for ON, ≥ 100 kΩ for OFF Installation Category II • Voltage Pulse: Square or sine waveforms Pollution Degree 2 Pulse width time requirement: 20 μsec. min. for high and Max. operating voltage 300 V low levels Input or output to power: Reinforced insulation Hi level: 2 – 50 V Input to output: Basic insulation Lo level: ≤ 1 V Approval: Input impedance: 10 kΩ min. UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (UL 1604, CAN/CSA-C22.2 No.213) OUTPUT SPECIFICATIONS UL/C-UL general safety requirements • DC Current: 0 – 20 mA DC (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. • DC Voltage: 0 – 12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V INSTALLATION Power Consumption •AC Power input: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 264 V •DC Power input: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lbs) http://www.m-system.co.jp/ M2SP SPECIFICATIONS ES-5056 Rev.13 Page 2/3 MODEL: M2SP DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 10 (.39) 84 (3.31) 15 (.59) 114 (4.49) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation Waveform Output + + 1 One-Shot Smoother 9 Shaper Driver INPUT OUTPUT – – 4 12 SENSOR EXCITATION + U(+) 5 12V Supply 13 POWER V(–) 8 14 Base Socket Input Connection Examples � Dry Contact � Voltage Pulse + 1 + 1 – – 4 4 – – +12V +12V PWR PWR + + 5 5 4kΩ Specifications are subject to change without notice. http://www.m-system.co.jp/ M2SP SPECIFICATIONS ES-5056 Rev.13 Page 3/3 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2SP?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods