M-SYSTEMS M2SES
Specifications
AC Power input
Approx. 3 VA at 100 V; Approx. 4 VA at 200 V; Approx. 5 VA at 264 V
Accuracy
±0.2 %
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC Power input
Approx. 3 W
Dielectric strength
1000 V AC @1 minute (input to output)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M Omega with 500 V DC
Isolation
Input to output to power
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range output
Approx. -10 to +120 % at 1 – 5 V
Response time
Less than 0.5 sec. (0 – 90 %)
Selecting operation
Automatic
Selecting sensitivity
0.5%
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
150 g (0.33 lbs)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring
- Monitors two DC input signals and transmits an output signal proportional to the higher or lower input
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
Model MODEL: M2SES Super-mini Signal Conditioners Mini-M Series [3] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) HIGH/LOW SELECTOR B: 2 – 10 mA DC (Load resistance 1500 Ω max.) Functions & Features C: 1 – 5 mA DC (Load resistance 3000 Ω max.) • Monitors two DC input signals and transmits an output D: 0 – 20 mA DC (Load resistance 750 Ω max.) signal proportional to the higher or lower input E: 0 – 16 mA DC (Load resistance 900 Ω max.) • CE marking F: 0 – 10 mA DC (Load resistance 1500 Ω max.) • UL approval G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Typical Applications Voltage • Selecting greater flow, pressure, etc. for control 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) • Heating control based on the highest temperature among 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) several T/C’s on a furnace 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 23 (.91) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) 76 (2.99) 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) 124 [4] POWER INPUT (4.88) mm (inch) AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) MODEL: M2SES–[1][2][3]–[4][5] (Select ‘/N’ for ‘Standards & Approvals’ code.) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, ORDERING INFORMATION 47 – 66 Hz) • Code number: M2SES-[1][2][3]-[4][5] (90 – 264 V for UL) Specify a code from below for [1] and [5]. DC Power (e.g. M2SES-2AA-M2/CE/Q) R: 24 V DC • Special output range (For codes Z & 0) (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) • Specify the specification for option code /Q R2: 11 – 27 V DC (e.g. /C01/S01) (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC [1] SELECTING FUNCTION (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) 1: Low input (110 V ±10 % for UL) 2: High input [5] OPTIONS (multiple selections) [2] INPUT STANDARDS & APPROVALS (must be specified) Current /N: Without CE or UL A: 4 – 20 mA DC (Input resistance 250 Ω) /CE: CE marking B: 2 – 10 mA DC (Input resistance 500 Ω) /UL: UL approval (CE marking) C: 1 – 5 mA DC (Input resistance 1000 Ω) OTHER OPTIONS H: 10 – 50 mA DC (Input resistance 100 Ω) blank: none Voltage /Q: Option other than the above (specify the specification) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) (UL not available) http://www.m-system.co.jp/ M2SES SPECIFICATIONS ES-5049 Rev.10 Page 1/3 MODEL: M2SES 2000 V AC @1 minute (input or output to power to ground) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating STANDARDS & APPROVALS /C02: Polyurethane coating CE conformity: /C03: Rubber coating EMC Directive (2004/108/EC) TERMINAL SCREW MATERIAL EN 61000-6-4 (EMI) /S01: Stainless steel EN 61000-6-2 (EMS) Low Voltage Directive (2006/95/EC) EN 61010-1 GENERAL SPECIFICATIONS Installation Category II Construction: Plug-in Pollution Degree 2 Connection: M3 screw terminals (torque 0.8 N·m) Max. operating voltage 300 V Housing material: Flame-resistant resin (black) Input or output to power: Reinforced insulation Isolation: Input to output to power Input to output: Basic insulation Overrange output: Approx. -10 to +120 % at 1 – 5 V Approval: Selecting operation: Automatic UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations INPUT SPECIFICATIONS (UL 1604, CAN/CSA-C22.2 No.213) • DC Current: Input resistor incorporated UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. • DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V INSTALLATION Power Consumption •AC Power input: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V •DC Power input: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lbs) PERFORMANCE in percentage of span Accuracy: ±0.2 % Selecting sensitivity: 0.5% Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1000 V AC @1 minute (input to output) http://www.m-system.co.jp/ M2SES SPECIFICATIONS ES-5049 Rev.10 Page 2/3 MODEL: M2SES DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 10 (.39) 84 (3.31) 15 (.59) 114 (4.49) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Isolation Output + Selector + 1 9 Driver * INPUT 1 OUTPUT – – 4 12 + U(+) 5 13 * INPUT 2 POWER – V(–) 8 14 Base Socket *Input shunt resistor incorporated for current inputs. Specifications are subject to change without notice. http://www.m-system.co.jp/ M2SES SPECIFICATIONS ES-5049 Rev.10 Page 3/3 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2SES?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods