M-SYSTEMS M2RTS
Specifications
AC Power input
Approx. 3 VA at 100 V; Approx. 4 VA at 200 V; Approx. 5 VA at 264 V
Accuracy
±0.2
Bias adjustment
-100 to +100 %; 1 % increments
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC Power input
Approx. 3 W
Dielectric strength
2000 V AC @1 minute (input to output to power to ground)
Housing Material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M omega with 500 V DC
Inverted
-0.10 to -4.00; 0.01 increments
Isolation
Input to output to power
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range output
Approx. -10 to +120 % at 1 – 5 V
Polarity indicator
Dual color (red/green) LED; Red with a positive set value; Green with a negative set value.
Power Saving Mode
Indicators turn off if the switches are untouched for 1 minute.
Proportional
0.10 to 4.00; 0.01 increments
Ratio/bias digital display
Red LED; 6.4 mm (.25”) 7 segments, 3 digits
Ratio/bias selector
Double-throw SW (front)
Response time
Less than 0.5 sec. (0 – 90 %)
Temp. Coefficient
±0.015 %/°C (±0.008 %/°F)
UP/DOWN control
Double-throw, momentary SW (front)
Weight
150 g (0.33 lbs)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Easy ratio/bias setting with the front digital display
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Provides precise matching of DC control signals to final control elements in open- or closed-loop systems
- Ratio adjustable from 0.1 to 4.00 or from -0.1 to -4.00; Bias adjustable to ±100 %
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
Model MODEL: M2RTS F: 0 – 10 mA DC (Input resistance 100 Ω) Super-mini Signal Conditioners Mini-M Series G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) RATIO/BIAS TRANSMITTER K: 0 – 100 μA DC (Input resistance 1000 Ω) (input bias) GW: -1 – +1 mA DC (Input resistance 1000 Ω) Functions & Features FW: -10 – +10 mA DC (Input resistance 100 Ω) • Provides precise matching of DC control signals to final Z: Specify current (See INPUT SPECIFICATIONS) control elements in open- or closed-loop systems Voltage • Easy ratio/bias setting with the front digital display 2: 0 – 100 mV DC (Input resistance 100 kΩ min.) • Ratio adjustable from 0.1 to 4.00 or from -0.1 to -4.00; 3: 0 – 1 V DC (Input resistance 1 MΩ min.) Bias adjustable to ±100 % 4: 0 – 10 V DC (Input resistance 1 MΩ min.) • CE marking 5: 0 – 5 V DC (Input resistance 1 MΩ min.) • UL approval 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) Typical Applications 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) • Ratio control for air/fuel flows or for two flows 0: Specify voltage (See INPUT SPECIFICATIONS) • Gain calculation for manipulated variable from a controller • Large scale signal span adjustment [3] OUTPUT Current 23 (.91) A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) 76 (2.99) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) 124 G: 0 – 1 mA DC (Load resistance 15 kΩ max.) (4.88) Z: Specify current (See OUTPUT SPECIFICATIONS) mm (inch) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) MODEL: M2RTS-[1]-[2][3]-[4][5] 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) ORDERING INFORMATION 5: 0 – 5 V DC (Load resistance 5000 Ω min.) • Code number: M2RTS-[1]-[2][3]-[4][5] 6: 1 – 5 V DC (Load resistance 5000 Ω min.) Specify a code from below for each [1] through [5]. 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) (e.g. M2RTS-S-6A-M2/CE/Q) 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) • Special input and output ranges (For codes Z & 0) 0: Specify voltage (See OUTPUT SPECIFICATIONS) • Specify the specification for option code /Q (e.g. /C01/S01) [4] POWER INPUT AC Power [1] OUTPUT CHARACTERISTICS M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, S: Proportional; ratio 0.1 to 4.00 47 – 66 Hz) R: Inverted; ratio -0.1 to -4.00 (90 – 264 V for UL) DC Power [2] INPUT R: 24 V DC Current (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) A: 4 – 20 mA DC (Input resistance 250 Ω) R2: 11 – 27 V DC A1: 4 – 20 mA DC (Input resistance 50 Ω) (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) B: 2 – 10 mA DC (Input resistance 500 Ω) (Select ‘/N’ for ‘Standards & Approvals’ code.) C: 1 – 5 mA DC (Input resistance 1000 Ω) P: 110 V DC D: 0 – 20 mA DC (Input resistance 50 Ω) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) E: 0 – 16 mA DC (Input resistance 62.5 Ω) http://www.m-system.co.jp/ M2RTS SPECIFICATIONS ES-5096 Rev.7 Page 1/4 MODEL: M2RTS (110 V ±10 % for UL) INPUT SPECIFICATIONS • DC Current: Shunt resistor attached to the input terminals (0.5 W) [5] OPTIONS (multiple selections) Specify input resistance value for code Z. STANDARDS & APPROVALS (must be specified) • DC Voltage: -30 – +30 V DC /N: Without CE or UL Minimum span: 100 mV /CE: CE marking Offset: Max. 1.5 times span /UL: UL approval (CE marking) Input resistance OTHER OPTIONS Span 0.1 – 1 V : ≥ 100 kΩ blank: none Span ≥ 1 V : ≥ 1 MΩ /Q: Option other than the above (specify the specification) (UL not available) OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC SPECIFICATIONS OF OPTION: Q (multiple selections) Minimum span: 1 mA COATING (For the detail, refer to M-System's web site.) Offset: Max. 1.5 times span /C01: Silicone coating Load resistance: Output drive 15 V max. /C02: Polyurethane coating • DC Voltage: -10 – +12 V DC /C03: Rubber coating Minimum span: 5 mV TERMINAL SCREW MATERIAL Offset: Max. 1.5 times span /S01: Stainless steel Load resistance: Output drive 1 mA max.; at ≥ 0.5 V GENERAL SPECIFICATIONS INSTALLATION Construction: Plug-in Power Consumption Connection: M3 screw terminals (torque 0.8 N·m) •AC Power input: Housing material: Flame-resistant resin (black) Approx. 3 VA at 100 V Isolation: Input to output to power Approx. 4 VA at 200 V Overrange output: Approx. -10 to +120 % at 1 – 5 V Approx. 5 VA at 264 V Ratio adjustment •DC Power input: Approx. 3 W Proportional: 0.10 to 4.00; 0.01 increments Operating temperature: -5 to +55°C (23 to 131°F) Inverted: -0.10 to -4.00; 0.01 increments Operating humidity: 30 to 90 %RH (non-condensing) Bias adjustment: -100 to +100 %; 1 % increments Mounting: Surface or DIN rail Ratio/bias selector: Double-throw SW (front) Weight: 150 g (0.33 lbs) UP/DOWN control: Double-throw, momentary SW (front) Equation: Xo = K (Xi + B) (proportional) Xo = K (Xi + B) + 100 % (inverted) PERFORMANCE in percentage of span where Accuracy: ±0.2 % Xo : Output (%) Ratio = 1, Bias = 0 % (proportional) K : Ratio Ratio = -1, Bias = 0 % (inverted) Linear characteristics Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) 0.1 to 4.00 (proportional) Response time: ≤ 0.5 sec. (0 – 90 %) -0.1 to -4.00 (inverted) Line voltage effect: ±0.1 % over voltage range Xi : Input (approx. -10 to +120 %) Insulation resistance: ≥ 100 MΩ with 500 V DC B : Bias (-100 to +100 %) Dielectric strength: 2000 V AC @1 minute (input to output ■ INDICATORS to power to ground) Ratio/bias digital display: Red LED; 6.4 mm (.25”) 7 segment, 3 digits STANDARDS & APPROVALS Polarity indicator: Dual color (red/green) LED; Red with a CE conformity: positive set value; Green with a negative set value. EMC Directive (2004/108/EC) Power saving mode: Indicators turn off if the switches are EN 61000-6-4 (EMI) untouched for 1 minute. EN 61000-6-2 (EMS) Low Voltage Directive (2006/95/EC) http://www.m-system.co.jp/ M2RTS SPECIFICATIONS ES-5096 Rev.7 Page 2/4 MODEL: M2RTS EN 61010-1 Installation Category II Pollution Degree 2 Max. operating voltage 300 V Input or output to power: Reinforced insulation Input to output: Basic insulation Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) EXTERNAL VIEW (A) Polarity Indicator LED (B) Ratio/Bias Display (C) Ratio/Bias Selector Top: Ratio Bottom: Bias (D) UP/DOWN Control (E) Zero Adj. (F) Span Adj. The front cover cannot be turned open by 180 deg. when there is no extra space between units. • How to Set the Ratio Adj. (E) the output Xo to 100 %. Turn the Ratio/Bias Selector (C) to the top. 3) Apply the calculated zero point input again and check the The Ratio/Bias Display (B) shows the current ratio (0.10 – output Xo. 4.00). Press UP/DOWN Control (D) until the display shows a 4) If the output has been shifted, go through (1) through (3) desired set value. again. The Polarity Indicator LED (A) is red when the set value is in positive range, green when in negative range. The unit is factory set and calibrated to the following ratio and bias values. • How to Set the Bias Proportional characteristics: ratio (K) = 1, Bias (B) = 0 % Turn the Ratio/Bias Selector (C) to the bottom. Inverted characteristics: ratio (K) = -1, Bias (B) = 0 % The Ratio/Bias Display (B) shows the current bias (0 – 100%). Press UP/DOWN Control (D) until the display shows a desired set value. The Polarity Indicator LED (A) is red when the set value is in positive range, green when in negative range. • Fine Calibration Equation: Xo = K(Xi + B) (proportional) Xo = K(Xi + B) + 100 % (inverted) 1) Calculate the input signal Xi which results in 0 % output. Apply the calculated input and adjust with Zero Adj. (E) the output Xo to 0 %. 2) Calculate the input signal Xi which results in 100 % output. Apply the calculated input and adjust with Span http://www.m-system.co.jp/ M2RTS SPECIFICATIONS ES-5096 Rev.7 Page 3/4 MODEL: M2RTS EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 7.3 (.29) 86.7 (3.41) 15 (.59) 116.7 (4.59) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) INPUT RESISTOR (model: REM2) 4 1 8 5 12 9 14 13 Input shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM RATIO/BIAS UP/DOWN SELECTOR SW Z S Isolation Low Drift Digital Output + + 1 9 * Amplifier Computation Driver INPUT R OUTPUT – – 4 12 5 13 U(+) Ratio/Bias POWER Display 8 14 V(–) Base Socket *Input shunt resistor attached for current input. Specifications are subject to change without notice. http://www.m-system.co.jp/ M2RTS SPECIFICATIONS ES-5096 Rev.7 Page 4/4 70.5 (2.78) 19 (.75) 59 (2.32) 4 (.16) 72 (2.83)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2RTS?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods