M-SYSTEMS M2PRU
Specifications
Chattering protection
Filter provided for mechanical contact input (time constant
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
Dielectric strength
2000 V AC @1 minute (input to output to power to ground)
Housing Material
Flame-resistant resin (black)
Input pulse sensing
DC coupled; capacitor coupling
Insulation resistance
Greater than 100 MO with 500 V DC
Isolation
Input to output to power
Output pulse width adjustment
Single-turn screwdriver adjustment (front); 5 µsec. – 400 msec. (one-shot type)
Output pulse width range selector
Double-throw SW (front)
Response time
25 µsec. + input cycle + output cycle
Scaling factor adjustment
10-position rotary switch (front); 1.0000 × 100 – 0.0001 × 10–6; factory set to 1.0000 × 100
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Converts pulse rate into convenient engineering unit for display on a totalizing counter or meter
- Excitation
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Scaling factor adjustable of 1.0000 × 100 to 0.0001 × 10–6
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- Three-way isolation
- Various outputs (open collector, voltage pulse and AC/DC switch)
Datasheet
Extracted Text
Model MODEL: M2PRU Super-mini Signal Conditioners Mini-M Series [3] OUTPUT A: Open collector (max. 100 kHz) M: 5 V pulse (max. 100 kHz) PULSE SCALER N: 12 V pulse (max. 100 kHz) (field-configurable) P: 24 V pulse (max. 100 kHz) Functions & Features R: AC/DC switch (max. 1 kHz) • Converts pulse rate into convenient engineering unit for display on a totalizing counter or meter • Excitation [4] POWER INPUT • Scaling factor adjustable of 1.0000 × 100 to 0.0001 × 10–6 AC Power • Various outputs (open collector, voltage pulse and AC/DC M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, switch) 47 – 66 Hz) • Three-way isolation (90 – 264 V for UL) • CE marking DC Power • UL approval R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) Typical Applications R2: 11 – 27 V DC • Positive displacement flowmeters and turbine flowmeters (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) • Magnetic tachometers (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC 23 (.91) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (110 V ±10 % for UL) 76 (2.99) [5] OPTIONS (multiple selections) STANDARDS & APPROVALS (must be specified) /N: Without CE or UL /CE: CE marking 124 (4.88) /UL: UL approval (CE marking) mm (inch) OTHER OPTIONS blank: none /Q: Option other than the above (specify the specification) MODEL: M2PRU–[1][2][3]–[4][5] (UL not available) ORDERING INFORMATION SPECIFICATIONS OF OPTION: Q (multiple selections) • Code number: M2PRU-[1][2][3]-[4][5] COATING (For the detail, refer to M-System's web site.) Specify a code from below for each [1] through [5]. /C01: Silicone coating (e.g. M2PRU-A24A-M2/CE/Q) /C02: Polyurethane coating • Scaling factor (e.g. 0.7000 × 10–2) /C03: Rubber coating • Specify the specification for option code /Q TERMINAL SCREW MATERIAL (e.g. /C01/S01) /S01: Stainless steel [1] INPUT CAUTION A1: Open collector 1) The M2PRU’s output waveform is not uniform due to its A2: Mechanical contact scaling method. The user must be aware that it may be C: Voltage pulse (sensitivity 2 V) inconvenient for certain types of application. H: Two-wire current pulse 2) The M2PRU is designed to accept at the maximum of 100 kHz, which may cause errors due to chattering in the input [2] EXCITATION pulses. 4: 12 V DC / 30 mA A filter circuitry (time constant: approx. 1 msec.) is 7: 24 V DC / 30 mA incorporated to eliminate unwanted chattering when the mechanical contact input is specified. It is effective for http://www.m-system.co.jp/ M2PRU SPECIFICATIONS ES-5076 Rev.11 Page 1/4 MODEL: M2PRU most relay types, however, an external CR filter as indicated ≥ 1200 Ω / 2.4 V for OFF below, could be added if the user need improvement. Limit • Voltage Pulse the input frequency to 10 Hz at maximum. Waveform: Square or sine Frequency range: 0 – 100 kHz R (min. 10 Hz for sine waves) C = 100 μF PULSE Relay C R = 100Ω SCALER Pulse width time requirement: ≥ 5 μsec. for high and low levels Input impedance: ≥ 10 kΩ Max. input voltage across the terminals: ±50 V GENERAL SPECIFICATIONS Detecting levels Construction: Plug-in DC coupled: ≥ 2 V DC for high level; ≤ 1 V DC for low level Connection: M3 screw terminals (torque 0.8 N·m) Capacitor coupled: ≥ 2 Vp-p Housing material: Flame-resistant resin (black) • Two-wire Current Pulse Isolation: Input to output to power Frequency range: 0 – 100 kHz Chattering protection: Filter provided for mechanical Pulse width time requirement: Min. 5 μsec. for high and low contact input (time constant: approx. 1 msec.) levels Input pulse sensing: DC coupled; capacitor coupling Detecting levels: (automatic trigger*) is field selectable with the side DIP ≥ 10 mA for high level switch for the voltage pulse input. ≤ 5 mA for low level *Capacitor coupling, with which the detecting levels are Maximum current: ±30 mA automatically set within two peaks of the waveforms, is Input resistance: Receiving resistor 200 Ω effective way to detect those with DC offset. However, it may be ineffective if the duty ratio is extremely high or low. OUTPUT SPECIFICATIONS The automatic trigger method can compensate such • Open Collector: 50 V DC @200 mA (resistive load) irregular pulses. Maximum frequency: 100 kHz Scaling factor adjustment: 10-position rotary switch (front); Saturation voltage: 0.6 V DC 1.0000 × 100 – 0.0001 × 10–6; factory set to 1.0000 × 100 if • Voltage Pulse not specified when ordering Maximum frequency: 100 kHz Output pulse width adjustment: Single-turn screwdriver High level: Rating (5, 12 or 24 V) ±10 % adjustment (front); 5 μsec. – 400 msec. (one-shot type); Low level: ≤ 0.5 V Factory set to 5 μsec. except for the mechanical contact Load resistance: input set to 15 msec. or AC/DC switch output set to 500 ≥ 500 Ω for 5 V μsec. ≥ 1200 Ω for 12 V (Min. 400 μsec. recommended for AC/DC switch output of ≥ 4800 Ω for 24 V which the internal voltage drop value may increase with a • AC/DC Switch: shorter pulse width.) 132 V AC @200 mA (cos ø = 1) Output pulse width range selector: Double-throw SW (front) 30 V DC @200 mA (resistive load) Maximum frequency: 1 kHz INPUT SPECIFICATIONS Internal voltage drop: ≤ 3 V Excitation: Shortcircuit protection; limited to approx. 40 mA at shortcircuit INSTALLATION • Open Collector Power Consumption Frequency range: 0 – 100 kHz •AC Power input: Pulse width time requirement: Min. 5 μsec. for ON and OFF Approx. 4 VA at 100 V Sensing: Approx. 24 V DC @2 mA Approx. 5 VA at 200 V Detecting levels: ≤ 400 Ω / 0.8 V for ON, Approx. 6 VA at 264 V ≥ 1200 Ω / 2.4 V for OFF •DC Power input: Approx. 3 W • Mechanical Contact Operating temperature: -5 to +55°C (23 to 131°F) Frequency range: 0 – 30 Hz Operating humidity: 30 to 90 %RH (non-condensing) Pulse width time requirement: Min. 10 msec. for ON and OFF Mounting: Surface or DIN rail Sensing: Approx. 24 V DC @2 mA Weight: 150 g (0.33 lbs) Detecting levels: ≤ 400 Ω / 0.8 V for ON, http://www.m-system.co.jp/ M2PRU SPECIFICATIONS ES-5076 Rev.11 Page 2/4 MODEL: M2PRU PERFORMANCE Response time: 25 μsec. + input cycle + output cycle (time required for the first pulse to be output from a train of pulse input) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EN 61000-6-4 (EMI) EN 61000-6-2 (EMS) Low Voltage Directive (2006/95/EC) EN 61010-1 Installation Category II Pollution Degree 2 Max. operating voltage 300V Input or output to power: Reinforced insulation Input to output Open collector/voltage pulse output: Basic insulation AC/DC switch output: Reinforced insulation Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) EXTERNAL VIEW � FRONT VIEW (with cover open) � RIGHT SIDE VIEW DC Scaling Factor AC Pulse Sensing Type Selector –1 (A) 10 DC : DC coupling –2 AC : Capacitor coupling (B) 10 –3 (C) 10 Pulse Width Adj. –4 (D) 10 Pulse Width Range Selector –n * (E) 10 *Settings 7 through 9 are invalid. No pulse output with these settings. The front cover cannot be opened to 180 deg. when flush with neighboring units. Refer to the instruction manual for detailed procedures. http://www.m-system.co.jp/ M2PRU SPECIFICATIONS ES-5076 Rev.11 Page 3/4 MODEL: M2PRU DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 7.3 (.29) 86.7 (3.41) 15 (.59) 116.7 (4.59) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM SCALING PULSE * FACTOR ADJ. WIDTH ADJ. PULSE SENSING PULSE WIDTH TYPE SELECTOR RANGE SELECTOR Isolation Waveform Output + 1 Scaler One-shot 9 + Shaper Driver INPUT OUTPUT – 4 12 – SENSOR EXCITATION Voltage + 5 13 U(+) Supply POWER 8 14 V(–) Base Socket *Provided only for voltage pulse input. Input Connection Examples Output Connection Examples � Mechanical Contact 24V � 2-Wire Current Pulse � Open Collector � Voltage Pulse Open Collector • Built-in Excitation 12kΩ 200Ω + + 1 – + + + + 1 9 9 – 2-WIRE – 4 – – – – 4 12 12 PICK-UP – Vsns PWR + + + 5 5 � Voltage Pulse • External DC Supply � AC/DC SWITCH • DC Coupled 200Ω + + – (+) 1 2-WIRE 1 9 PICK-UP + – – (–) 4 4 12 DC SUPPLY – Vsns PWR + + + 5 5 – • Capacitor Coupled + + 1 – – 4 – PWR + + 5 Specifications are subject to change without notice. http://www.m-system.co.jp/ M2PRU SPECIFICATIONS ES-5076 Rev.11 Page 4/4 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2PRU?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods