M-SYSTEMS M2PP
Specifications
Chattering protection
Filter provided for mechanical contact input
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
Dielectric strength
2000 V AC @1 minute (input to output to power to ground)
Excitation
12 V DC @30 mA; short-circuit protection
Frequency Range
Input and output are the same.
Hi/Lo level
2 – 50 V for high level; 1 V for low level
Housing Material
Flame-resistant resin (black)
Input impedance
10 kO min
Input pulse sensing
DC coupled
Isolation
Input to output to power
Mechanical Contact Maximum frequency
30 Hz
Mechanical Contact Pulse width time requirement
10 msec. min. for ON and OFF
Mechanical Contact Sensing
Approx. 12 V DC @3 mA
Open Collector Maximum frequency
10 kHz
Open Collector Pulse width time requirement
10 µsec. min. for ON and OFF
Open Collector Sensing
Approx. 12 V DC @3 mA
Voltage Pulse Maximum frequency
10 kHz
Voltage Pulse Pulse width time requirement
10 µsec. min. for high and low levels
Waveforms
Square or sine
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
Model MODEL: M2PP Super-mini Signal Conditioners Mini-M Series [3] OUTPUT LOGIC N: The same as the input R: Inverted PULSE ISOLATOR Functions & Features • Galvanically isolates pulse rate signals [4] POWER INPUT • Input frequency = output frequency AC Power • Various outputs (relay, open collector and voltage M: 85 – 264 V AC (Operational voltage range 85 – 264 V, pulses) 47 – 66 Hz) • CE marking (Select ‘/N’ for ‘Standards & Approvals’ code.) • UL approval for 24 V DC power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) Typical Applications (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) • Isolating field pulse signals in order to reduce noises DC Power • Changing e.g. dry contact signal to e.g. 5 V signals R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) 23 (.91) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) 76 P: 110 V DC (2.99) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) 124 (4.88) [5] OPTIONS (multiple selections) mm (inch) STANDARDS & APPROVALS (must be specified) /N: Without CE or UL /CE: CE marking MODEL: M2PP–[1][2][3]–[4][5] /UL: UL approval (CE marking) OTHER OPTIONS ORDERING INFORMATION blank: none • Code number: M2PP-[1][2][3]-[4][5] /Q: Option other than the above (specify the specification) Specify a code from below for [1] through [5]. (UL not available) (e.g. M2PP-33N-M2/CE/Q) • Specify the specification for option code /Q SPECIFICATIONS OF OPTION: Q (multiple selections) (e.g. /C01/S01) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating [1] INPUT /C02: Polyurethane coating 1: Mechanical contact (max. frequency 30 Hz) /C03: Rubber coating 2: Open collector (max. frequency 10 kHz) TERMINAL SCREW MATERIAL 3: Voltage pulse (max. frequency 10 kHz) /S01: Stainless steel [2] OUTPUT GENERAL SPECIFICATIONS 1: Low frequency open collector (max. frequency 30 Hz) Construction: Plug-in 2: High frequency open collector (max. 10 kHz) Connection: M3 screw terminals (torque 0.8 N·m) 3: 5 V pulse (max. frequency 10 kHz) Housing material: Flame-resistant resin (black) 4: 12 V pulse (max. frequency 10 kHz) Isolation: Input to output to power 5: 24 V pulse (max. frequency 10 kHz) Frequency range: Input and output are the same. 6: Mercury relay contact (max. frequency 30 Hz) Chattering protection: Filter provided for mechanical (Select ‘/N’ for ‘Standards & Approvals’ code) contact input (Not conformed to RoHS Directive) Input pulse sensing: DC coupled http://www.m-system.co.jp/ M2PP SPECIFICATIONS ES-5061 Rev.12 Page 1/4 MODEL: M2PP ≥ 5 × 107 cycles, electrical INPUT SPECIFICATIONS Excitation: 12 V DC @30 mA; shortcircuit protection • Open Collector INSTALLATION Maximum frequency: 10 kHz Power Consumption Pulse width time requirement: 10 μsec. min. for ON and OFF •AC Power input: Sensing: Approx. 12 V DC @3 mA Approx. 3 VA at 100 V ON/OFF level: ≤200 Ω for ON, ≥100 kΩ for OFF Approx. 4 VA at 200 V • Mechanical Contact Approx. 5 VA at 264 V Maximum frequency: 30 Hz •DC Power input: Approx. 3 W Pulse width time requirement: 10 msec. min. for ON and Operating temperature: -5 to +55°C (23 to 131°F) OFF Operating humidity: 30 to 90 %RH (non-condensing) Sensing: Approx. 12 V DC @3 mA Mounting: Surface or DIN rail ON/OFF level: ≤200 Ω for ON, ≥100 kΩ for OFF Weight: 150 g (0.33 lbs) • Voltage Pulse Maximum frequency: 10 kHz PERFORMANCE Pulse width time requirement: 10 μsec. min. for high and Insulation resistance: ≥ 100 MΩ with 500 V DC low levels Dielectric strength: 2000 V AC @1 minute (input to output Waveforms:Square or sine to power to ground) Hi/Lo level: 2 – 50 V for high level; ≤1 V for low level Input impedance: 10 kΩ min. STANDARDS & APPROVALS CE conformity: OUTPUT SPECIFICATIONS EMC Directive (2004/108/EC) • Low Frequency Open Collector: EN 61000-6-4 (EMI) 50 V DC @100 mA (resistive load) EN 61000-6-2 (EMS) Maximum frequency: 30 Hz Low Voltage Directive (2006/95/EC) Timer: Limits within 75 ±25 msec. EN 61010-1 ON time for output logic non-inverted Installation Category II OFF time for output logic inverted Pollution Degree 2 Saturation voltage: 0.5 V DC Max. operating voltage 300 V • High Frequency Open Collector: Input or output to power: Reinforced insulation 50 V DC @100 mA (resistive load) Input to output: Basic insulation Maximum frequency: 10 kHz Approval: Saturation voltage: 0.5 V DC UL nonincendive Class I, Division 2, • Voltage Pulse Groups A, B, C, and D hazardous locations Maximum frequency: 10 kHz (UL 1604) High level: Rating (5, 12 or 24 V) ±10 % UL general safety requirements Low level: ≤ 0.5V (UL 61010B-1) Load resistance: ≥ 250 Ω for 5 V ≥ 600 Ω for 12 V ≥ 1200 Ω for 24 V • Mercury Relay Contact Maximum frequency: 30 Hz Timer: Limits within 75 ±25 msec. ON time for output logic non-inverted OFF time for output logic inverted Rated load: 132 V AC @200 mA (cos ø = 1) 30 V DC @200 mA (resistive load) Maximum switching voltage: 350 V AC or 500 V DC Maximum switching current: 200 mA AC or 300 mA DC Maximum switching power: 26 VA or 6 W Relay life: ≥ 5 × 108 cycles, mechanical http://www.m-system.co.jp/ M2PP SPECIFICATIONS ES-5061 Rev.12 Page 2/4 MODEL: M2PP OUTPUT LOGIC VOLTAGE PULSE OPEN COLLECTOR INPUT TYPE PULSE LOGIC INPUT OUTPUT or RELAY OUTPUT H H OFF Non Inverted L L ON Voltage Pulse Input H H OFF Inverted L L ON OFF H OFF Non Inverted ON L ON Mechanical Contact Open Collector OFF H OFF Inverted ON L ON DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 10 (.39) 84 (3.31) 15 (.59) 114 (4.49) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. http://www.m-system.co.jp/ M2PP SPECIFICATIONS ES-5061 Rev.12 Page 3/4 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2PP SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Isolation * Waveform Output + 1 Timer 9 + Shaper Driver INPUT OUTPUT – 4 12 – SENSOR EXCITATION + 5 12V Supply 13 U(+) POWER 8 14 V(–) Base Socket *Low freq. open collector and mercury relay output only. Input Connection Examples Output Connection Examples � Mechanical Contact or Open Collector � Open Collector � Relay • AC Powered Relay or Counter Coil + + 1 + + 9 9 Varistor or Spark – Quenching Circuit – 4 – – LOAD 12 12 – +12V PWR + + 5 4kΩ � Voltage Pulse • DC Powered � Voltage Pulse Relay or Counter Coil + + 9 9 Spark Quenching Diode + + 1 – – LOAD 12 12 – – 4 – +12V PWR + + 5 Specifications are subject to change without notice. http://www.m-system.co.jp/ M2PP SPECIFICATIONS ES-5061 Rev.12 Page 4/4
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2PP?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods