M-SYSTEMS M2PHS
Specifications
AC Power input
Approx. 3 VA at 100 V; Approx. 4 VA at 200 V; Approx. 5 VA at 264 V
Accuracy
±0.2 %
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC Power input
Approx. 3 W
Dielectric strength
2000 V AC @1 minute (input to output to power to ground)
Hold control
Holds when opening the terminals 5 – 8; Tracks when closing them
Housing material
Flame-resistant resin (black)
Insulation resistance
greater than 100 M omega with 500 V DC
Isolation
Input to output to power
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Over-range input
Approx. -10 to +120 % at 1 – 5 V
Over-range output
Approx. -10 to +120 % at 1 – 5 V
Response time
less than 0.5 sec. (0 – 90 %)
Span adjustment
95 to 105 % (front)
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Weight
150 g (0.33 lbs)
Zero adjustment
-5 to +5 % (front)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring
- Peak-hold mode: responds only to an increasing signal, holding the maximum value until higher signal or a command to reset is received
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- Track mode: the output follows proportionally to the input
- Valley hold and peak-to-peak mode selectable
Datasheet
Extracted Text
Model ZERO SPAN MODEL: M2PHS F: 0 – 10 mA DC (Input resistance 100 Ω) Super-mini Signal Conditioners Mini-M Series G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) PEAK HOLD J: 0 – 10 μA DC (Input resistance 1000 Ω) Functions & Features K: 0 – 100 μA DC (Input resistance 1000 Ω) • Track mode: the output follows proportionally to the input GW: -1 – +1 mA DC (Input resistance 1000 Ω) • Peak-hold mode: responds only to an increasing signal, FW: -10 – +10 mA DC (Input resistance 100 Ω) holding the maximum value until a higher signal or a Z: Specify current (See INPUT SPECIFICATIONS) command to reset is received Voltage • Valley hold and peak-to-peak mode selectable 1: 0 – 10 mV DC (Input resistance 10 kΩ min.) • CE marking 15: 0 – 50 mV DC (Input resistance 10 kΩ min.) • UL approval 16: 0 – 60 mV DC (Input resistance 10 kΩ min.) 2: 0 – 100 mV DC (Input resistance 100 kΩ min.) Typical Applications 3: 0 – 1 V DC (Input resistance 1 MΩ min.) • Monitoring peak power consumption 4: 0 – 10 V DC (Input resistance 1 MΩ min.) • Monitoring the highest or lowest temperature 5: 0 – 5 V DC (Input resistance 1 MΩ min.) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 23 (.91) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) 76 (2.99) [3] OUTPUT Current 124 A: 4 – 20 mA DC (Load resistance 750 Ω max.) (4.88) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) mm (inch) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) MODEL: M2PHS[1]-[2][3]-[4][5] E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) ORDERING INFORMATION Z: Specify current (See OUTPUT SPECIFICATIONS) • Code number: M2PHS[1]-[2][3]-[4][5] Voltage Specify a code from below for each [1] through [5]. 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) (e.g. M2PHSH-6A-M2/CE/Q) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) • Special input and output ranges (For codes Z & 0) 3: 0 – 1 V DC (Load resistance 1000 Ω min.) • Specify the specification for option code /Q 4: 0 – 10 V DC (Load resistance 10 kΩ min.) (e.g. /C01/S01) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) [1] HOLD FUNCTION 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) H: Peak hold 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) L: Valley hold 0: Specify voltage (See OUTPUT SPECIFICATIONS) W: Peak-to-peak hold (Select ‘/N’ or ‘/CE’ for ‘Standards & Approvals’ code) [4] POWER INPUT AC Power [2] INPUT M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Current 47 – 66 Hz) A: 4 – 20 mA DC (Input resistance 250 Ω) (90 – 264 V for UL) A1: 4 – 20 mA DC (Input resistance 50 Ω) DC Power B: 2 – 10 mA DC (Input resistance 500 Ω) R: 24 V DC C: 1 – 5 mA DC (Input resistance 1000 Ω) (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) D: 0 – 20 mA DC (Input resistance 50 Ω) R2: 11 – 27 V DC E: 0 – 16 mA DC (Input resistance 62.5 Ω) http://www.m-system.co.jp/ M2PHS SPECIFICATIONS ES-5086 Rev.7 Page 1/4 MODEL: M2PHS (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) Detection levels: ≤ 1.25 kΩ / 1 V at Track (Select ‘/N’ for ‘Standards & Approvals’ code.) ≥ 20 kΩ / 4 V at Hold P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) OUTPUT SPECIFICATIONS (110 V ±10 % for UL) • DC Current: 0 – 20 mA DC Minimum span: 1 mA [5] OPTIONS (multiple selections) Offset: Max. 1.5 times span STANDARDS & APPROVALS (must be specified) Load resistance: Output drive 15 V max. /N: Without CE or UL • DC Voltage: -10 – +12 V DC /CE: CE marking Minimum span: 5 mV /UL: UL approval (CE marking) Offset: Max. 1.5 times span OTHER OPTIONS Load resistance: Output drive 1 mA max.; at ≥ 0.5 V blank: none /Q: Option other than the above (specify the specification) INSTALLATION (UL not available) Power Consumption •AC Power input: SPECIFICATIONS OF OPTION: Q (multiple selections) Approx. 3 VA at 100 V COATING (For the detail, refer to M-System's web site.) Approx. 4 VA at 200 V /C01: Silicone coating Approx. 5 VA at 264 V /C02: Polyurethane coating •DC Power input: Approx. 3 W /C03: Rubber coating Operating temperature: -5 to +55°C (23 to 131°F) TERMINAL SCREW MATERIAL Operating humidity: 30 to 90 %RH (non-condensing) /S01: Stainless steel Mounting: Surface or DIN rail Weight: 150 g (0.33 lbs) GENERAL SPECIFICATIONS Construction: Plug-in PERFORMANCE in percentage of span Connection: M3 screw terminals (torque 0.8 N·m) Accuracy: ±0.2 % Housing material: Flame-resistant resin (black) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Isolation: Input to output to power Response time: ≤ 0.5 sec. (0 – 90 %) Overrange input: Approx. -10 to +120 % at 1 – 5 V Line voltage effect: ±0.1 % over voltage range Overrange output: Approx. -10 to +120 % at 1 – 5 V Insulation resistance: ≥ 100 MΩ with 500 V DC Zero adjustment: -5 to +5 % (front) Dielectric strength: 2000 V AC @1 minute (input to output Span adjustment: 95 to 105 % (front) to power to ground) Hold control: Holds when opening the terminals 5 – 8; Tracks when closing them STANDARDS & APPROVALS CE conformity: INPUT SPECIFICATIONS EMC Directive (2004/108/EC) • DC Current: EN 61000-6-4 (EMI) Shunt resistor attached to the input terminals (0.5 W) EN 61000-6-2 (EMS) Specify input resistance value for code Z. Low Voltage Directive (2006/95/EC) • DC Voltage: -300 – +300 V DC EN 61010-1 Minimum span: 3 mV Installation Category II Offset: Max. 1.5 times span Pollution Degree 2 Input resistance Max. operating voltage 300 V Span 3 – 10 mV : ≥ 10 kΩ Input or output to power: Reinforced insulation Span 10 – 100 mV : ≥ 10 kΩ Input to output: Basic insulation Span 0.1 – 1 V : ≥ 100 kΩ Approval: Span ≥ 1 V : ≥ 1 MΩ UL/C-UL nonincendive Class I, Division 2, • Hold Control Groups A, B, C, and D hazardous locations Contact rating: 5 V @ 1 mA (UL 1604, CAN/CSA-C22.2 No.213) http://www.m-system.co.jp/ M2PHS SPECIFICATIONS ES-5086 Rev.7 Page 2/4 MODEL: M2PHS UL/C-UL general safety requirements (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 10 (.39) 84 (3.31) 15 (.59) 114 (4.49) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) INPUT RESISTOR (model: REM2) 4 1 8 5 12 9 14 13 Input shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation Low Drift Digital Output + 1 9 + * Amplifier Computation Driver INPUT R OUTPUT – 4 12 – +5V 5kΩ 13 U(+) POWER 5 14 V(–) HOLD CONTROL 8 Close: Track Open : Hold Base Socket *Input shunt resistor attached for current input. http://www.m-system.co.jp/ M2PHS SPECIFICATIONS ES-5086 Rev.7 Page 3/4 70.5 (2.78) 19 (.75) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2PHS Specifications are subject to change without notice. http://www.m-system.co.jp/ M2PHS SPECIFICATIONS ES-5086 Rev.7 Page 4/4
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2PHS?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods