M-SYSTEMS M2MNV
Specifications
(signal channel to switching command contact to power)
Performance
AC Power input
Approx. 3 VA at 100 V; Approx. 4 VA at 200 V; Approx. 5 VA at 264V
Connection
M3 screw terminals (torque 0.8 N•m)
Construction
Plug-in
DC Power input
Approx. 2 W
Dielectric strength
2000 V AC @1 minute (switching command contact to power to ground); 2000 V AC @1 minute (signal channel to power to ground); 1500 V AC @1 minute (signal channel to switching command contact)
Housing material
Flame-resistant resin (black)
Insulation resistance
Greater than 100 M Omega with 500 V DC
Isolation
Signal channel to switching command contact to power
Leakage current at open circuit
Less than 1 µA
Line voltage effect
±0.1 % over voltage range
Mounting
Surface or DIN rail
Operating humidity
30 to 90 %RH (non-condensing)
Operating temperature
-5 to +55°C (23 to 131°F)
Power indicator LED
Green light turns on when the power is supplied.
Status indicator LED 1
Green light turns on when the signal channel 1 (A1-B1) is alive.
Status indicator LED 2
Green light turns on when the signal channel 2 (A2-B1) is alive.
Switching
Photo MOS relay
Switching response time
less than 5 msec
Temp. coefficient
±0.010 %/°C (±0.006 %/°F) (input code 2)
Weight
150 g (0.33 lbs)
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
- Switches between two analog signal channels
- Switches/Distributes one voltage signal to two channels
Datasheet
Extracted Text
Model MODEL: M2MNV M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, Super-mini Signal Conditioners Mini-M Series 47 – 66 Hz) DC Power ANALOG SWITCHING MODULE R: 24 V DC Functions & Features (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) • Switches between two analog signal channels R2: 11 – 27 V DC • Switches/Distributes one voltage signal to two channels (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) • CE marking (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC Typical Applications (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) • Switching 1 – 5V DC signal: no contact failure that happens when using mechanical contacts for this purpose [4] OPTIONS (multiple selections) • Switching low-speed pulse signals Standards & Approvlas (must be specified) /N: Without CE 29.5 (1.16) /CE: CE marking Other Options blank: none 76 (2.99) /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) 124 (4.88) COATING (For the detail, refer to M-System's web site.) mm (inch) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL MODEL: M2MNV-[1][2]-[3][4] /S01: Stainless steel ORDERING INFORMATION GENERAL SPECIFICATIONS • Code number: M2MNV-[1][2]-[3][4] Construction: Plug-in Specify a code from below for each [1] through [4]. Connection: M3 screw terminals (torque 0.8 N·m) (e.g. M2MNV-11-M2/CE/Q) Housing material: Flame-resistant resin (black) • Specify the specification for option code /Q Switching: Photo MOS relay (e.g. /C01/S01) Isolation: Signal channel to switching command contact to Note: Must be used with its socket. NOT installable to a power multi-unit installation base. (e.g. model: M2BS-16) Power indicator LED: Green light turns on when the power is supplied. Status indicator LED 1: Green light turns on when the signal [1] SWITCHING CONTROL channel 1 (A1-B1) is alive. 1: Interlocking switching control (single-pole contact) Status indicator LED 2: Green light turns on when the signal 2: Independent switching control (double-pole contact) channel 2 (A2-B1) is alive. [2] INPUT INPUT & OUTPUT 1: Current signal (no receiving resistor) ■ Signal Channels 2: Current signal (receiving resistor 50 Ω) Max. operational voltage range: ±50 V DC (min. span 10 3: Voltage signal mV) Max. operational current range: ±50 mA DC (min. span 1 [3] POWER INPUT mA) AC Power Receiving resistor: 50 Ω incorporated (input code 2) M: 85 – 264 V AC (Operational voltage range 85 – 264 V, ON resistance: ≤ 50 Ω per wire 47 – 66 Hz) (ON resistance of photo MOS relay) (Select ‘/N’ for ‘Standards & Approvals’ code.) http://www.m-system.co.jp/ M2MNV SPECIFICATIONS ES-5095 Rev.4 Page 1/6 MODEL: M2MNV ■ Output insulation (300 V) Current signal input (no receiving resistor): Equal to the input signal Current signal input (receiving resistor 50 Ω): Voltage signal equal to [Current × 50 Ω] Voltage signal input: Equal to the input signal ■ Switching Command: Relay or open collector Contact detecting: 5 V DC / 1 mA Detecting levels: ≤ 1 kΩ at ON / ≥ 10 kΩ at OFF INSTALLATION Power Consumption •AC Power input: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V •DC power input: Approx. 2 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lbs) PERFORMANCE in percentage of span Accuracy: ±0.1 % (input code 2) Temp. coefficient: ±0.010 %/°C (±0.006 %/°F) (input code 2) Switching response time: ≤ 5 msec. Leakage current at open circuit: ≤ 1 μA Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC (signal channel to switching command contact to power) Dielectric strength: 2000 V AC @1 minute (switching command contact to power to ground) 2000 V AC @1 minute (signal channel to power to ground) 1500 V AC @1 minute (signal channel to switching command contact) STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 Signal channel or switching command contact to power: Reinforced insulation (300 V) Signal channel to switching command contact: Basic http://www.m-system.co.jp/ M2MNV SPECIFICATIONS ES-5095 Rev.4 Page 2/6 MODEL: M2MNV EXTERNAL VIEW • Channel 1 Status LED 1 • Channel 2 Status LED 2 Power LED DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 21.5 (.85) 10 (.39) 84 (3.31) 22 (.87) 114 (4.49) [4 (.16)] 29.5 (1.16) • When mounting, no extra space is needed between units. http://www.m-system.co.jp/ M2MNV SPECIFICATIONS ES-5095 Rev.4 Page 3/6 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2MNV SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM � INTERLOCKING SWITCHING CONTROL (single-pole contact) 2 * A1-1 1 7 B1-1 1 50Ω * A1-2 2 8 B1-2 A2-1 4 1 50Ω * A2-2 5 POWER STATUS STATUS LED LED 1 LED 2 5V 5kΩ Photo MOSFET 3 10 U(+) Relay Driver POWER SWITCHING SW1 6 11 V(–) COMMAND 9 Base Socket *1. Provided only with the input code 2: Current signal (receiving resistor 50Ω). *2. Provided only with the input code 1: Current signal (no receiving resistor). *1/*2 Not provided with the input code 3. A1-B1 channel is connected when the SW1 is turned on (closed). A2-B1 channel is connected when the SW1 is turned off (open). � INDEPENDENT SWITCHING CONTROL (double-pole contact) 2 * A1-1 1 7 B1-1 1 50Ω * A1-2 2 8 B1-2 A2-1 4 1 50Ω * A2-2 5 POWER STATUS STATUS LED LED 1 LED 2 5V 5kΩ Photo MOSFET 3 10 U(+) Relay Driver POWER 5V 11 V(–) SW1 SWITCHING 5kΩ COMMAND 6 SW2 9 Base Socket *1. Provided only with the input code 2: Current signal (receiving resistor 50Ω). *2. Provided only with the input code 1: Current signal (no receiving resistor). *1/*2 Not provided with the input code 3. A1-B1 channel is connected when the SW1 is turned on (closed). A2-B1 channel is connected when the SW2 is turned on (closed). http://www.m-system.co.jp/ M2MNV SPECIFICATIONS ES-5095 Rev.4 Page 4/6 MODEL: M2MNV SWITCHING OPERATIONS � INTERLOCKING SWITCHING CONTROL (single-pole contact) Single contact is used to switch from Signal Channel 1 (A1-B1) to Signal Channel 2 (A2-B1) and vice versa. CHANNEL 1 (A1) CHANNEL 2 (A2) Terminal 3 – 9 OFF (open) OFF ON Terminal 3 – 9 ON (closed) ON OFF Status LED turn on when the respective channels are alive. • Switching Status Current Signal (receiving resistor 50Ω) Current Signal (no receiving resistor) Voltage Signal *1 1 7 1 7 2 8 2 8 Power : OFF *1 Switching command : OFF (open) 4 4 5 5 *1 1 7 1 7 2 8 2 8 Power : ON *1 Switching command : OFF (open) 4 4 5 5 *1 1 7 1 7 2 8 2 8 Power : ON *1 Switching command : ON (short) 4 4 5 5 *1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50Ω). Transition (ON to OFF, OFF to ON) Status Current Signal (receiving resistor 50Ω) Current Signal (no receiving resistor) Voltage Signal *1 1 7 1 7 2 8 2 8 Power : ON *1 Switching command : OFF to ON 4 4 or 5 5 Power : ON Switching command : ON to OFF When the switching command contact is switched from When the switching command contact is switched from OFF to ON or from ON to OFF, the signal channel is OFF to ON or from ON to OFF, the signal channel is switched only after all photo MOS relays turn on switched only after all photo MOS relays turn off (closed). (open). *1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50Ω). � INDEPENDENT SWITCHING CONTROL (double-pole contact) Double contacts are used to independently switch Signal Channel 1 (A1-B1) and Signal Channel 2 (A2-B1). CHANNEL 1 (A1) CHANNEL 2 (A2) Terminal 3 – 9 OFF (open) OFF ---- Terminal 3 – 9 ON (closed) ON ---- Terminal 6 – 9 OFF (open) ---- OFF Terminal 6 – 9 ON (closed) ---- ON Status LED turn on when the respective channels are alive. http://www.m-system.co.jp/ M2MNV SPECIFICATIONS ES-5095 Rev.4 Page 5/6 MODEL: M2MNV Specifications are subject to change without notice. http://www.m-system.co.jp/ M2MNV SPECIFICATIONS ES-5095 Rev.4 Page 6/6
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2MNV?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods