M-SYSTEMS M2LCS
Datasheet
Extracted Text
Model MODEL: M2LCS 7: 20 mV/V Super-mini Signal Conditioners Mini-M Series 0: Specify (strain gauge and excitation) STRAIN GAUGE TRANSMITTER [2] OUTPUT Functions & Features Current • Provides a DC output signal compatible with a bridge type A: 4 – 20 mA DC (Load resistance 750 Ω max.) strain gauge utilized in load cells, pressure transducers B: 2 – 10 mA DC (Load resistance 1500 Ω max.) • Supplies required excitation voltage C: 1 – 5 mA DC (Load resistance 3000 Ω max.) • Excitation adjustable from 2 V to 10 V D: 0 – 20 mA DC (Load resistance 750 Ω max.) • Wide-range adjustment: 0 – 80 % for zero, 100 – 20 % for E: 0 – 16 mA DC (Load resistance 900 Ω max.) span F: 0 – 10 mA DC (Load resistance 1500 Ω max.) • Three-way isolation G: 0 – 1 mA DC (Load resistance 15 kΩ max.) • CE marking Z: Specify current (See OUTPUT SPECIFICATIONS) • UL approval Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) Typical Applications 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) • Weighing system for tanks, hoppers, silos 3: 0 – 1 V DC (Load resistance 1000 Ω min.) • Weighing system using cranes 4: 0 – 10 V DC (Load resistance 10 kΩ min.) • Float level meter utilizing strain gauges 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 29.5 (1.16) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) 76 (2.99) [3] POWER INPUT AC Power 124 (4.88) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, mm (inch) 47 – 66 Hz) (90 – 264 V for UL) DC Power MODEL: M2LCS–[1][2]–[3][4] R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) ORDERING INFORMATION R2: 11 – 27 V DC • Code number: M2LCS-[1][2]-[3][4] (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) Specify a code from below for each [1] through [4]. (Select ‘/N’ for ‘Standards & Approvals’ code.) (e.g. M2LCS-2A-M2/K/CE/Q) P: 110 V DC • Special output range (For codes Z & 0) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) • Specify the specification for option code /Q (110 V ±10 % for UL) (e.g. /C01/S01) Note: Must be used with its socket. NOT installable to a [4] OPTIONS (multiple selections) multi-unit installation base. (e.g. model: M2BS-16) Response Time (0 – 90 %) blank: Standard (≤ 0.5 sec.) [1] INPUT STRAIN GAUGE /K: Fast Response (Approx. 25 msec.) 1: 1 mV/V Standards & Approvlas (must be specified) 12: 1.25 mV/V /N: Without CE or UL 15: 1.5 mV/V /CE: CE marking 2: 2 mV/V /UL: UL approval, CE marking 3: 3 mV/V Other Options 4: 4 mV/V blank: none 5: 5 mV/V /Q: Option other than the above (specify the specification) 6: 10 mV/V (UL not available) http://www.m-system.co.jp/ M2LCS SPECIFICATIONS ES-5047 Rev.8 Page 1/4 MODEL: M2LCS Weight: 150 g (0.33 lbs) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating PERFORMANCE in percentage of span /C02: Polyurethane coating Accuracy: ±0.1 % (Input ≥ 3 mV) /C03: Rubber coating Linearity: ±0.05 % (Input ≥3 mV) TERMINAL SCREW MATERIAL Temp. coefficient: ±0.02 %/°C (±0.01 %/°F) (input ≥ 3 mV) /S01: Stainless steel Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output GENERAL SPECIFICATIONS to power to ground) Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Housing material: Flame-resistant resin (black) STANDARDS & APPROVALS Isolation: Input to output to power CE conformity: Overrange output: Approx. -10 to +120 % at 1 – 5 V EMC Directive (2004/108/EC) Excitation adjustment: 2 – 10 V (front) EMI EN 61000-6-4: 2007 Zero adjustments (tare): 0 – 80 % (front) EMS EN 61000-6-2: 2005 (May not applicable when the excitation voltage is changed Low Voltage Directive (2006/95/EC) after shipment.) EN 61010-1: 2001 Span adjustment: 100 – 20 % (front) Installation Category II (May not applicable when the excitation voltage is changed Pollution Degree 2 after shipment.) Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) Approval: INPUT SPECIFICATIONS UL/C-UL nonincendive Class I, Division 2, ■ Input: Bridge voltage from load cells Groups A, B, C, and D hazardous locations • Strain Gauge (ANSI/ISA-12.12.01:2007, CAN/CSA-C22.2 No.213:1987) Rated output from strain gauge: 1 – 20 mV/V; UL/C-UL general safety requirements Input to the M2LCS must be over 3mV. (UL 61010B-1:2003, CAN/CSA-C22.2 No.61010-1:1992) • Excitation: 2 – 10 V adjustable (5 V standard) Maximum current: 35 mA OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. ■ DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V INSTALLATION Power Consumption •AC Power input: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V •DC power input: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail http://www.m-system.co.jp/ M2LCS SPECIFICATIONS ES-5047 Rev.8 Page 2/4 MODEL: M2LCS FRONT VIEW (with the cover open) Auxiliary Coarse Zero Adj. Excitation Adj. 16-position Coarse Zero Adj. 16-position Coarse Span Adj. Fine Zero Adj. Fine Span Adj. • Coarse Zero Adj. (auxiliary): Used when the zero cannot be adjusted with only the coarse and fine zero adjustments. • Excitation Adj.: Factory adjusted. • Coarse Zero Adj.: Tare adjustment. Approx. 5 % of input span adjustable with each increment. Max. 80 % by 16 positions. • Coarse Span Adj.: Gain adjustment. 100 – 20 % of input span adjusted by 16 positions. • Fine Zero Adj.: Tare adjustment • Fine Span Adj.: Gain adjustment EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 21.5 (.85) 7.3 (.29) 86.7 (3.41) 22 (.87) 116.7 (4.59) [4 (.16)] 29.5 (1.16) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM COM 3 Isolation Z S STRAIN GAUGE Output + 1 7 + Low Drift Driver Voltage OUTPUT – 2 Amplifier 8 – + U(+) 4 Low Drift 10 EXC. DC Volt. POWER – Stabilizer V(–) 5 11 6 8 Base Socket http://www.m-system.co.jp/ M2LCS SPECIFICATIONS ES-5047 Rev.8 Page 3/4 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2LCS Specifications are subject to change without notice. http://www.m-system.co.jp/ M2LCS SPECIFICATIONS ES-5047 Rev.8 Page 4/4
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2LCS?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods