M-SYSTEMS M2CE
Specifications
Connection
M3 screw terminals (torque 0.8 N·m)
Construction
Plug-in
DC Current
0 – 20 mA DC
DC VOLTAGE
0 – 12 V DC
Frequency
50 or 60 Hz
Housing material
Flame-resistant resin (black)
Isolation
Input to output to power
Load resistance
Output drive 1 mA max.; at = 0.5 V
Minimum span
5 mV
Offset
Max. 1.5 times span
Operational range
0 – 120 % of rating
Overload capacity
500 % of rating for 5 sec., 120 % continuous
Overrange output
0 to 120 % at 1 – 5 V
RMS sensing
Up to 15 % of 3rd harmonic content
Span adjustment
95 to 105 % (front)
Zero adjustment
-5 to +5 % (front)
Datasheet
Extracted Text
Model ZERO SPAN MODEL: M2CE D: 0 – 20 mA DC (Load resistance 750 Ω max.) Super-mini Signal Conditioners Mini-M Series E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) CT TRANSMITTER G: 0 – 1 mA DC (Load resistance 15 kΩ max.) (RMS sensing) Z: Specify current (See OUTPUT SPECIFICATIONS) Functions & Features Voltage • Converts alternating current from a current transformer 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) into a standard process signal 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) • Minimum ripple 3: 0 – 1 V DC (Load resistance 1000 Ω min.) • Rerouted input signal does not pass through the base 4: 0 – 10 V DC (Load resistance 10 kΩ min.) socket in order to protect it from melting caused by rush 5: 0 – 5 V DC (Load resistance 5000 Ω min.) current of a motor 6: 1 – 5 V DC (Load resistance 5000 Ω min.) • CT Protector provided for open-circuit protection 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) • CE marking 0: Specify voltage (See OUTPUT SPECIFICATIONS) • UL approval [3] POWER INPUT Typical Applications AC Power • Centralized monitoring and control of motors, pumps or M: 85 – 264 V AC (Operational voltage range 85 – 264 V, heaters by DCS 47 – 66 Hz) • Monitoring power line and power supply current (Select ‘/N’ for ‘Standards & Approvals’ code.) 23 (.91) 23 (.91) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (90 – 264 V for UL) DC Power 76 (2.99) R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC 124 (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (4.88) (Select ‘/N’ for ‘Standards & Approvals’ code.) mm (inch) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) MODEL: M2CE–[1][2]-[3][4] (110 V ±10 % for UL) ORDERING INFORMATION [4] OPTIONS (multiple selections) • Code number: M2CE-[1][2]-[3][4] STANDARDS & APPROVALS (must be specified) Specify a code from below for [1] through [4]. /N: Without CE or UL (e.g. M2CE-5A-M2/CE/Q) /CE: CE marking • Special output range (For codes Z & 0) /UL: UL approval (CE marking) • Specify the specification for option code /Q OTHER OPTIONS (e.g. /C01/S01) blank: none /Q: Option other than the above (specify the specification) (UL not available) [1] INPUT Current 1: 0 – 1 A AC SPECIFICATIONS OF OPTION: Q (multiple selections) 5: 0 – 5 A AC COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating [2] OUTPUT /C03: Rubber coating Current TERMINAL SCREW MATERIAL A: 4 – 20 mA DC (Load resistance 750 Ω max.) /S01: Stainless steel B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) http://www.m-system.co.jp/ M2CE SPECIFICATIONS ES-5121 Rev.2 Page 1/3 MODEL: M2CE to power to ground) GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) STANDARDS & APPROVALS Housing material: Flame-resistant resin (black) CE conformity: Isolation: Input to output to power EMC Directive (2004/108/EC) Input waveform EN 61000-6-4 (EMI) RMS sensing: Up to 15 % of 3rd harmonic content EN 61000-6-2 (EMS) Overrange output: 0 to 120 % at 1 – 5 V Low Voltage Directive (2006/95/EC) Zero adjustment: -5 to +5 % (front) EN 61010-1 Span adjustment: 95 to 105 % (front) Installation Category II Pollution Degree 2 Max. operating voltage 300 V INPUT SPECIFICATIONS Input or output to power: Reinforced insulation Frequency: 50 or 60 Hz Input to output: Basic insulation Input burden: Approval: ≤ 0.1 VA (input 0 – 1 A) UL/C-UL nonincendive Class I, Division 2, ≤ 0.5 VA (input 0 – 5 A) Groups A, B, C, and D hazardous locations Overload capacity: 500 % of rating for 5 sec., 120 % (UL 1604, CAN/CSA-C22.2 No.213) continuous UL/C-UL general safety requirements Operational range: 0 – 120 % of rating (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. • DC Voltage: 0 – 12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V INSTALLATION Power Consumption •AC Power input: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V •DC Power input: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lbs) PERFORMANCE in percentage of span Accuracy: ±0.3 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Ripple: 0.5 %p-p max. (100/120 Hz) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output http://www.m-system.co.jp/ M2CE SPECIFICATIONS ES-5121 Rev.2 Page 2/3 MODEL: M2CE EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) approx. 200 (7.9) CT PROTECTOR (total of both sides) (model: CTM2) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 10 (.39) 84 (3.31) 15 (.59) 114 (4.49) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM SOURCE Z S INPUT K k TRANSFORMER RMS / Ave. Output 1 9 + Operation Driver CT OUTPUT 4 12 – l L 5 13 U(+) LOAD POWER 8 14 V(–) CT PROTECTOR Base Socket model: CTM2 Specifications are subject to change without notice. http://www.m-system.co.jp/ M2CE SPECIFICATIONS ES-5121 Rev.2 Page 3/3 70.5 (2.78) 59 (2.32) 4 (.16) 72 (2.83) 28 (1.10)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2CE?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods