M-SYSTEMS M2AS
Specifications
Codes 1, 2
Rating ±25 msec.
Codes 3 to 8
Rating ±20 %
Connection
M3 screw terminals (torque 0.8 N-m)
Construction
Plug-in
DC Current
Shunt resistor attached to the input terminals (0.5 W)
Dead-band (hysteresis)
Thumbwheel switches (front); 1 – 99 % independently; 1 % increments (latching output when set to 00)
Dead-band set-point accuracy
±0.5 %
Delay time (response time with 90 % set-point for a step input 0 – 100 %)
Performance
Dielectric strength
2000 V AC @1 minute (input to output to power to ground)
Front LEDs
Red light turns on when the coil is energized.
Housing Material
Flame-resistant resin (black)
Isolation
Input to output to power
Line voltage effect
±0.1 % over voltage range
Maximum switching power
600 VA (360 VA with enclosed relay) or 150 W
Maximum switching voltage
250 V AC or 30 V DC
Mechanical life
5 × 107 cycles
Minimum Load
5 V DC @10 mA
Over-range input
-14 to +113.5 %
Power ON timer
Rating ±0.5 sec.
Reset Contact Input
ON resistance:
Reset input
Latched output reset with the front control button or remotely via base socket terminals
Set-point accuracy
±0.5 %
Set-point adjustments
Thumbwheel switches (front); 0 – 99 % independently; 1 % increments
Temp. coefficient
±0.015 %/°C (±0.008 %/°F)
Trip point repeatability
±0.05 %
Features
- 2000V AC isolation
- Base socket included with modules
- CE marking and UL/C-UL Class 1 Div 2 approval (selected models)
- Fixed range or PC programmable models selectable
- M2 use a compact-size, plug-in socket base for quick installation or replacement of modules without disturbing wiring.
- Selectable 100-240V AC/24V DC power input
- Standard DIN rail or surface mounting
Datasheet
Extracted Text
4 4 3 1 MODEL: M2AS Super-mini Signal Conditioners Mini-M Series [3] ON DELAY TIME 1: 0.05 second 2: 0.1 second DC ALARM 3: 0.2 second (thumbwheel switch adjustment; DPDT output) 4: 0.5 second Functions & Features 5: 1 second • Provides a DPDT relay output at a preset DC input level 6: 2 seconds • Thumbwheel switch setpoint adjustments 7: 5 seconds • Adjustable deadband 8: 10 seconds • Latching or non-latching output • Relays energized or de-energized at tripped condition • CE marking [4] POWER ON DELAY TIME 1: 1 second Typical Applications 2 : 2 seconds • Annunciator 3 : 3 seconds • Various alarm applications 4 : 4 seconds 29.5 (1.16) [5] RELAY TYPE N: Standard type 76 (2.99) S: Enclosed type [6] POWER INPUT 124 AC Power (4.88) mm (inch) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power MODEL: M2AS–[1][2][3][4][5]–[6][7] R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC ORDERING INFORMATION (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) • Code number: M2AS-[1][2][3][4][5]-[6][7] (Select ‘/N’ for ‘Standards & Approvals’ code.) Specify a code from below for each [1] through [7]. P: 110 V DC (e.g. M2AS-6111S-M2/CE/Q) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) • Specify the specification for option code /Q (e.g. /C01/S01) Note: Must be used with its socket. NOT installable to a [7] OPTIONS (multiple selections) multi-unit installation base. (e.g. model: M2BS-16) Standards & Approvlas (must be specified) /N: Without CE /CE: CE marking [1] INPUT Other Options Current blank: none A: 4 – 20 mA DC (Input resistance 250 Ω) /Q: Option other than the above (specify the specification) Voltage 4: 0 – 10 V DC (Input resistance 1 MΩ min.) 5: 0 – 5 V DC (Input resistance 1 MΩ min.) SPECIFICATIONS OF OPTION: Q (multiple selections) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating [2] ALARM OUTPUT /C03: Rubber coating 1: Hi (coil energized at alarm) TERMINAL SCREW MATERIAL 2: Hi (coil de-energized at alarm) /S01: Stainless steel 3: Lo (coil energized at alarm) 4: Lo (coil de-energized at alarm) http://www.m-system.co.jp/ M2AS SPECIFICATIONS ES-5063 Rev.6 Page 1/5 MODEL: M2AS GENERAL SPECIFICATIONS INSTALLATION Construction: Plug-in Power Consumption Connection: M3 screw terminals (torque 0.8 N·m) •AC Power input: Housing material: Flame-resistant resin (black) Approx. 3 VA at 100 V Isolation: Input to output to power Approx. 4 VA at 200 V Overrange input: -14 to +113.5 % Approx. 5 VA at 264 V When the relay’s untripped point relative to the preset •DC power input: Approx. 3 W alarm setpoint and deadband is out of this range, the relay Operating temperature: -5 to +55°C (23 to 131°F) remains latched. Operating humidity: 30 to 90 %RH (non-condensing) Setpoint adjustments: Thumbwheel switches (front); Mounting: Surface or DIN rail 0 – 99 % independently; 1 % increments Installation Base (model: M2BS) is not adaptable. Deadband (hysteresis) : Thumbwheel switches (front); Weight: 150 g (0.33 lbs) 1 – 99 % independently; 1 % increments (latching output when set to 00) PERFORMANCE in percentage of span Front LEDs: Red light turns on when the coil is energized. Setpoint accuracy: ±0.5 % Reset input: Latched output reset with the front control Deadband setpoint accuracy: ±0.5 % button or remotely via base socket terminals. Delay time (response time with 90 % setpoint for a step input 0 – 100 %) INPUT SPECIFICATIONS Codes 1, 2: Rating ±25 msec. ■ DC Current: Codes 3 to 8: Rating ±20 % Shunt resistor attached to the input terminals (0.5 W) Power ON timer: Rating ±0.5 sec. ■ Reset Contact Input Trip point repeatability: ±0.05 % ON resistance: ≤ 1 kΩ Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) OFF resistance: ≥ 50 kΩ Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output OUTPUT SPECIFICATIONS to power to ground) ■ Relay Contact: 120 V AC @5 A (cos ø = 1)(120 V @3 A with enclosed relay) 240 V AC @2.5 A (cos ø = 1) STANDARDS & APPROVALS 30 V DC @5 A (resistive load) CE conformity: Maximum switching voltage: 250 V AC or 30 V DC EMC Directive (2004/108/EC) Maximum switching power: 600 VA (360 VA with enclosed EMI EN 61000-6-4: 2007 relay) or 150 W EMS EN 61000-6-2: 2005 Minimum load: 5 V DC @10 mA Low Voltage Directive (2006/95/EC) Mechanical life: 5 × 107 cycles EN 61010-1: 2001 Installation Category II Alarm Trip Operation Terminal No. in parentheses Pollution Degree 2 • Output Code : 1, 4 Input or output to power: Reinforced insulation (300 V) (3–6)(5–7)ON Input to output: Basic insulation (300 V) Output (3–9)(5–8)ON Input (%) 0 50 � 100 Setpoint • Output Code : 2, 3 (3–6)(5–7)ON Output (3–9)(5–8)ON Input (%) 0 � 50 100 Setpoint Trip Operation in Power Failure: Terminals 3 – 9 and 5 – 8 turn on. http://www.m-system.co.jp/ M2AS SPECIFICATIONS ES-5063 Rev.6 Page 2/5 MODEL: M2AS EXTERNAL VIEW Output Setpoint Adj. 9 9 Deadband Adj. 9 9 Output Monitor LED Reset Control DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 3 2 1 35mm wide 6 5 4 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 9 8 7 11–M3 SCREW 11 10 21.5 (.85) 7.3 (.29) 86.7 (3.41) 22 (.87) 116.7 (4.59) [4 (.16)] 29.5 (1.16) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) INPUT RESISTOR (model: REM2) 3 2 1 6 5 4 9 8 7 11 10 Input shunt resistor attached for current input. http://www.m-system.co.jp/ M2AS SPECIFICATIONS ES-5063 Rev.6 Page 3/5 70.5 (2.78) 19 (.75) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2AS SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM � Relay Protection • AC Powered Inductive THUMBWHEEL Load (Coil) 9 9 Converter SWITCHES LOAD 9 N.C. Low Drift Ry + 1 * Amplifier 6 N.O. OUTPUT INPUT R Varistor or CR Circuit – Comparator 2 3 COM RESET • DC Powered RESET CONTROL Inductive 4 8 N.C. Load (Coil) 7 N.O. OUTPUT LOAD THUMBWHEEL Converter 9 9 SWITCHES 5 COM Diode, Varistor or CR Circuit 10 U(+) POWER 11 V(–) Base Socket *Input shunt resistor attached for current input. FUNCTIONS n POWER ON DELAY TIME: The relay does not provide n HIGH ALARM: When the signal input exceeds the preset setpoint, the relay provides a tripped a tripped condition for a duration of the preset Power ON Delay Time (TDP) after the power supply is turned condition. on, even when the signal input is in an alarm range. • Hi Alarm Input Setpoint • Power ON Delay Time (TDP) with Hi Alarm Deadband Input TDP Setpoint Deadband t Bold Line : Alarm Tripped Thin Line : Alarm Untripped Power ON t n LOW ALARM: When the signal input goes below Bold Line: Coil Energized the preset setpoint, the relay provides a tripped condition • Lo Alarm Input n LATCHING OUTPUT: The relay does not return to an untripped condition once the signal input goes across the threshold, unless: Deadband (1) the Reset control button is pressed, Setpoint (2) the Reset input terminal is closed, or (3) the power supply is removed. t Bold Line : Alarm Tripped Thin Line : Alarm Untripped • Latching Output with Hi Alarm n ON DELAY TIME: The relay status does not change Input until after the preset ON Delay Time (TD) once the signal input goes across the threshold. Setpoint • ON Delay Time (TD) with Hi Alarm Reset Command Input TD T
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the M2AS?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods