Specifications

Accuracy

±0.1 %

Connection

M3 screw terminals (torque 0.8 N-m)

Construction

Plug-in

Dielectric strength

2000 V AC @1 minute (input to output to power to ground)

Housing material

Flame-resistant resin (black)

Insulation resistance

= 100 MO with 500 V DC

Isolation

Input to output to power

Line voltage effect

±0.1 % over voltage range

Response time

Approx. 3 sec. (0 – 90 %)

Span adjustment

95 to 105 % (front)

Temp. coefficient

±0.015 %/°C (±0.008 %/°F

Zero adjustment

0 – 5 % (front)

Features

Datasheet

pdf file

M2AP-2017616846.pdf

93 KiB

Extracted Text

Model ZERO SPAN MODEL: M2AP Super-mini Signal Conditioners Mini-M Series [2] OUTPUT 1: Open collector (max. frequency 1 kHz) 2: 5 V pulse (max. frequency 1 kHz) DC/FREQUENCY CONVERTER 3: Mercury relay contact (max. frequency 30 Hz) Functions & Features (Select ‘/N’ for ‘Standards & Approvals’ code.) • Provides a pulse rate output in proportion to DC input (Not conformed to RoHS Directive) signal • CE marking • UL approval [3] POWER INPUT AC Power Typical Applications M: 85 – 264 V AC (Operational voltage range 85 – 264 V, • Totalizing applications in combination with a counter 47 – 66 Hz) (Select ‘/N’ for ‘Standards & Approvals’ code.) 23 (.91) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (90 – 264 V for UL) 76 DC Power (2.99) R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC 124 (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (4.88) mm (inch) (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) MODEL: M2AP-[1][2]-[3][4] (Select ‘/N’ for ‘Standards & Approvals’ code.) ORDERING INFORMATION [4] OPTIONS (multiple selections) Specify a code from below for each [1] through [4]. STANDARDS & APPROVALS (must be specified) • Code number: M2AP-[1][2]-[3][4] /N: Without CE or UL (e.g. M2AP-61-M2/CE/Q) /CE: CE marking Specify variables. /UL: UL approval (CE marking) • Output frequency range (e.g. 0 – 500 Hz) OTHER OPTIONS • Specify the specification for option code /Q blank: none (e.g. /C01/S01) /Q: Option other than the above (specify the specification) (UL not available) [1] INPUT Current SPECIFICATIONS OF OPTION: Q (multiple selections) A: 4 – 20 mA DC (Input resistance 250 Ω) COATING (For the detail, refer to M-System's web site.) D: 0 – 20 mA DC (Input resistance 50 Ω) /C01: Silicone coating G: 0 – 1 mA DC (Input resistance 1000 Ω) /C02: Polyurethane coating H: 10 – 50 mA DC (Input resistance 100 Ω) /C03: Rubber coating Z: Specify current (See INPUT SPECIFICATIONS) TERMINAL SCREW MATERIAL ( 0 % input must be 0 mA.) /S01: Stainless steel Voltage 3: 0 – 1 V DC (Input resistance 1 MΩ min.) GENERAL SPECIFICATIONS 4: 0 – 10 V DC (Input resistance 1 MΩ min.) Construction: Plug-in 5: 0 – 5 V DC (Input resistance 1 MΩ min.) Connection: M3 screw terminals (torque 0.8 N·m) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) Housing material: Flame-resistant resin (black) 0: Specify voltage (See INPUT SPECIFICATIONS) Isolation: Input to output to power ( 0 % input must be 0 V.) Zero adjustment: 0 – 5 % (front) Span adjustment: 95 to 105 % (front) http://www.m-system.co.jp/ M2AP SPECIFICATIONS ES-5051 Rev.12 Page 1/4 MODEL: M2AP INPUT SPECIFICATIONS INSTALLATION • DC Current: Power Consumption Shunt resistor attached to the input terminals (0.5 W) •AC Power input: Specify input resistance value for code Z. Approx. 3 VA at 100 V • DC Voltage: 0 – 300V DC Approx. 4 VA at 200 V Minimum span: 1V Approx. 5 VA at 264 V Input resistance: 1 MΩ min. •DC Power input: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) OUTPUT SPECIFICATIONS Mounting: Surface or DIN rail • Open Collector: 30 V DC @100 mA (resistive load) Weight: 150 g (0.33 lbs) Frequency range: 0 – 10 pulses/hour through 1 kHz Saturation voltage: 0.6 V DC • 5 V Pulse PERFORMANCE in percentage of span Frequency range: 0 – 10 pulses/hour through 1 kHz Accuracy: ±0.1 % Hi level: 3.0 – 5.5 V Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Lo level: ≤ 0.5 V Response time: Approx. 3 sec. (0 – 90 %) Load resistance: 250 Ω min. Line voltage effect: ±0.1 % over voltage range • Mercury Relay Contact Insulation resistance: ≥ 100 MΩ with 500 V DC Frequency range: 0 – 10 pulses/hour through 30 Hz Dielectric strength: 2000 V AC @1 minute (input to output Timer: Limits ON time ≤ 75 ±25 millisec. to power to ground) Rated load: 132 V AC @200mA (cos ø = 1) 30 V DC @200 mA (resistive load) STANDARDS & APPROVALS Maximum switching voltage: 350 V AC or 500 V DC CE conformity: Maximum switching current: 200 mA AC or 300 mA DC EMC Directive (2004/108/EC) Maximum switching power: 26 VA or 6 W EN 61000-6-4 (EMI) Relay life: ≥ 5 × 108 cycles, mechanical EN 61000-6-2 (EMS) ≥ 5 × 107 cycles, electrical Low Voltage Directive (2006/95/EC) EN 61010-1 OUTPUT PULSE WIDTH Installation Category II Pollution Degree 2 � Frequency less than 500 Hz at 100% input Max. operating voltage 300 V � Duty ratio 20% (See the figure below) • Open Collector • Voltage Pulse Input or output to power: Reinforced insulation OFF H Level Input to output: Basic insulation Approval: ON L Level 20% 80% 20% 80% UL/C-UL nonincendive Class I, Division 2, 1 / f 1 / f Groups A, B, C, and D hazardous locations � Frequency greater than 500 Hz at 100% input (UL 1604, CAN/CSA-C22.2 No.213) � See the figure and equation below. UL/C-UL general safety requirements • Open Collector • Voltage Pulse (UL 61010B-1, CAN/CSA-C22.2 No.1010-1) OFF H Level ON L Level Pulse Width Pulse Width 1 Pulse Width [millisec.] = 2.09 x 100% Frequency [kHz] � Mercury Relay Contact � See the figure below. ON pulse width is limited within 75 ±25 ms when the output frequency is low. • Relay OFF ON 20% 80% 1 / f http://www.m-system.co.jp/ M2AP SPECIFICATIONS ES-5051 Rev.12 Page 2/4 MODEL: M2AP DIMENSIONS unit: mm (inch) 6 (.23) DIN RAIL 4 1 35mm wide 8 5 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 12 9 8–M3 SCREW 14 13 21.5 (.85) 10 (.39) 84 (3.31) 15 (.59) 114 (4.49) [4 (.16)] 23 (.91) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) INPUT RESISTOR (model: REM2) 4 1 8 5 12 9 14 13 Input shunt resistor attached for current input. http://www.m-system.co.jp/ M2AP SPECIFICATIONS ES-5051 Rev.12 Page 3/4 70.5 (2.78) 19 (.75) 59 (2.32) 4 (.16) 72 (2.83) MODEL: M2AP SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z S Isolation ** Low Drift Volt. / Freq. Output + 1 Divider Timer 9 + * Amplifier Converter Driver INPUT R OUTPUT – 4 12 – 5 13 U(+) POWER 8 14 V(–) Base Socket * Input shunt resistor attached for current input. **Mercury relay contact only. Output Connection Examples � Open Collector � Relay • AC Powered Relay or Counter Coil + + 9 9 Varistor or Spark Quenching Circuit – – LOAD 12 12 � Voltage Pulse • DC Powered Relay or Counter Coil + + 9 9 Spark Quenching Diode – – LOAD 12 12 Specifications are subject to change without notice. http://www.m-system.co.jp/ M2AP SPECIFICATIONS ES-5051 Rev.12 Page 4/4

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the M2AP?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

M-Systems 20VS1A Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (High Speed Response, 3-...

product

M-Systems 20VS1B Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (input isolation)

product

M-Systems 20VS2-01 Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (3-Port Isolation)

product

M-Systems 20VS2-02 Hybrid Isolation Amplifiers 20 Series; Isolation Amplifier (3-Port Isolation)

product

M-Systems 20VS2-1 Hybrid Isolation Amplifiers 20 Series Isolation Amplifier (input isolation)

product

M-Systems 20VS2-2 Hybrid Isolation Amplifiers 20 Series Isolation Amplifier (output isolation)