INTEL BX80602E5504
Specifications
# of Cores
4
# of Memory Channels
3
# of QPI Links
2
# of Threads
4
Bus/Core Ratio
15
Clock Speed
2 GHz
ECC Memory Supported
Yes
Embedded Options Available
Yes
Instruction Set
64-bit
Intel QPI Speed
4.8 GT/s
Intel Smart Cache
4 MB
Lithography
45 nm
Max CPU Configuration
2
Max Memory Bandwidth
19.2 GB/s
Max Memory Size (dependent on memory type)
144 GB
Max TDP
80 W
Memory Types
DDR3 800
Package Size
42.5mm x 45mm
Physical Address Extensions
40-bit
Sockets Supported
FCLGA1366
TCASE
76°C
VID Voltage Range
0.75V -1.35V
Datasheet
Extracted Text
Intel® Xeon® Processor 5500 Series Datasheet, Volume 1 June 2011 Document Number: 321321-002 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel® Xeon® Processor 5500 Series may contain design defects or errors known as errata which may cause the product to deviate from published specifications.Current characterized errata are available on request. Intel processor numbers are not a measure of performance. Processor numbers differentiate features within each processor family, not across different processor families. See http://www.intel.com/products/processor_number for details. Over time processor numbers will increment based on changes in clock, speed, cache, FSB, or other features, and increments are not intended to represent proportional or quantitative increases in any particular feature. Current roadmap processor number progression is not necessarily representative of future roadmaps. See www.intel.com/products/processor_number for details. Hyper-Threading Technology requires a computer system with a processor supporting HT Technology and an HT Technology- enabled chipset, BIOS and operating system. Performance will vary depending on the specific hardware and software you use. For more information including details on which processors support HT Technology, see http://www.intel.com/products/ht/hyperthreading_more.htm Enabling Execute Disable Bit functionality requires a PC with a processor with Execute Disable Bit capability and a supporting operating system. Check with your PC manufacturer on whether your system delivers Execute Disable Bit functionality. 64-bit computing on Intel architecture requires a computer system with a processor, chipset, BIOS, operating system, device drivers and applications enabled for Intel® 64 architecture. Performance will vary depending on your hardware and software configurations. Consult with your system vendor for more information. Intel® Virtualization Technology requires a computer system with an enabled Intel® processor, BIOS, virtual machine monitor (VMM) and, for some uses, certain computer system software enabled for it. Functionality, performance or other benefits will vary depending on hardware and software configurations and may require a BIOS update. Software applications may not be compatible with all operating systems. Please check with your application vendor. Intel® Turbo Boost Technology requires a PC with a processor with Intel Turbo Boost Technology capability. Intel Turbo Boost Technology performance varies depending on hardware, software and overall system configuration. Check with your PC manufacturer on whether your system delivers Intel Turbo Boost Technology. For more information, see www.intel.com. Enhanced Intel SpeedStep® Technology. See the http://processorfinder.intel.com or contact your Intel representative for more information. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Intel, Xeon, Enhanced Intel SpeedStep Technology, and the Intel logo are trademarks of Intel Corporation in the United States and other countries. *Other brands and names are the property of their respective owners. Copyright © 2009-2011, Intel Corporation. ® ® 2 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Contents 1Introduction ..............................................................................................................9 1.1 Terminology ..................................................................................................... 10 1.2 References ....................................................................................................... 12 1.3 Statement of Volatility ....................................................................................... 12 2 Intel® Xeon® Processors 5500 Series Electrical Specifications ............................... 13 2.1 Processor Signaling ........................................................................................... 13 ® 2.1.1 Intel QuickPath Interconnect ................................................................. 13 2.1.2 DDR3 Signal Groups ............................................................................... 13 2.1.3 Platform Environmental Control Interface (PECI) ........................................ 14 2.1.4 Processor Sideband Signals ..................................................................... 14 2.1.5 System Reference Clock.......................................................................... 14 2.1.6 Test Access Port (TAP) Signals ................................................................. 15 2.1.7 Power / Other Signals ............................................................................. 15 2.1.8 Reserved or Unused Signals..................................................................... 23 2.2 Signal Group Summary ...................................................................................... 23 2.3 Mixing Processors.............................................................................................. 25 2.4 Flexible Motherboard Guidelines (FMB)................................................................. 26 2.5 Absolute Maximum and Minimum Ratings ............................................................. 26 2.6 Processor DC Specifications ................................................................................ 27 2.6.1 VCC Overshoot Specifications................................................................... 31 2.6.2 Die Voltage Validation............................................................................. 32 3 Package Mechanical Specifications .......................................................................... 43 3.1 Package Mechanical Specifications ....................................................................... 43 3.1.1 Package Mechanical Drawing.................................................................... 44 3.1.2 Processor Component Keep-Out Zones...................................................... 47 3.1.3 Package Loading Specifications ................................................................ 47 3.1.4 Package Handling Guidelines.................................................................... 47 3.1.5 Package Insertion Specifications............................................................... 47 3.1.6 Processor Mass Specification.................................................................... 48 3.1.7 Processor Materials................................................................................. 48 3.1.8 Processor Markings................................................................................. 48 3.1.9 Processor Land Coordinates ..................................................................... 48 4Land Listing............................................................................................................. 49 4.1 Intel® Xeon® Processors 5500 Series Pin Assignments.......................................... 49 4.1.1 Land Listing by Land Name...................................................................... 49 4.1.2 Land Listing by Land Number................................................................... 67 5 Signal Definitions .................................................................................................... 85 5.1 Signal Definitions .............................................................................................. 85 6 Thermal Specifications ............................................................................................ 89 6.1 Package Thermal Specifications........................................................................... 89 6.1.1 Thermal Specifications ............................................................................ 89 6.1.2 Thermal Metrology ............................................................................... 102 6.2 Processor Thermal Features.............................................................................. 103 6.2.1 Processor Temperature ......................................................................... 103 6.2.2 Adaptive Thermal Monitor...................................................................... 103 6.2.3 On-Demand Mode ................................................................................ 105 6.2.4 PROCHOT# Signal ................................................................................ 105 6.2.5 THERMTRIP# Signal ............................................................................. 106 6.3 Platform Environment Control Interface (PECI).................................................... 106 6.3.1 PECI Client Capabilities ......................................................................... 107 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 3 6.3.2 Client Command Suite...........................................................................108 6.3.3 Multi-Domain Commands.......................................................................124 6.3.4 Client Responses ..................................................................................124 6.3.5 Originator Responses ............................................................................125 6.3.6 Temperature Data ................................................................................126 6.3.7 Client Management ...............................................................................127 7Features ................................................................................................................131 7.1 Power-On Configuration (POC)...........................................................................131 7.2 Clock Control and Low Power States...................................................................132 7.2.1 Thread and Core Power State Descriptions ...............................................133 7.2.2 Package Power State Descriptions...........................................................134 7.2.3 Intel Xeon Processor 5500 Series C-State Power Specifications ...................135 7.3 Sleep States ...................................................................................................136 ® 7.4 Intel Turbo Boost Technology..........................................................................136 ® 7.5 Enhanced Intel SpeedStep Technology .............................................................136 8 Boxed Processor Specifications..............................................................................137 8.1 Introduction....................................................................................................137 8.1.1 Available Boxed Thermal Solution Configurations ......................................137 8.1.2 An Intel “Combo” Boxed Passive / Active Combination Heat Sink Solution.....137 8.1.3 Intel Boxed “Active” Heat Sink Solution ...................................................138 8.1.4 Intel Boxed 25.5mm Tall Passive Heat Sink Solution..................................139 8.2 Mechanical Specifications..................................................................................140 8.2.1 Boxed Processor Heat Sink Dimensions and Baseboard Keepout Zones ........140 8.2.2 Boxed Processor Retention Mechanism and Heat Sink Support (URS)......................................................................................149 8.3 Fan Power Supply (“Combo” and “Active” Solution) ..............................................150 8.3.1 Boxed Processor Cooling Requirements....................................................151 8.4 Boxed Processor Contents.................................................................................153 ® ® 4 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Figures 2-1 Active ODT for a Differential Link Example ............................................................ 13 2-2 Input Device Hysteresis ..................................................................................... 14 2-3 VCC Static and Transient Tolerance Loadlines1,2,3,4.............................................. 31 2-4 VCC Overshoot Example Waveform...................................................................... 32 2-5 Load Current Versus Time (130W TDP Processor),2................................................ 33 2-6 Load Current Versus Time (95W TDP Processor),2 ................................................. 34 2-7 Load Current Versus Time (80W TDP Processor),2 ................................................. 35 2-8 Load Current Versus Time (60W TDP Processor),2 ................................................. 36 2-9 Load Current Versus Time (38W TDP Processor),2 ................................................. 37 2-10 VTT Static and Transient Tolerance Loadlines ........................................................ 39 3-1 Processor Package Assembly Sketch .................................................................... 43 3-2 Processor Package Drawing (Sheet 1 of 2)............................................................ 45 3-3 Processor Package Drawing (Sheet 2 of 2)............................................................ 46 3-4 Processor Top-Side Markings .............................................................................. 48 6-1 Intel® Xeon® Processor W5580 Thermal Profile.................................................... 91 6-2 Intel® Xeon® Processor 5500 Series Advanced SKU Thermal Profile........................ 93 6-3 Intel Xeon Processor 5500 Series Standard/Basic SKUs Thermal Profile .................... 95 6-4 Intel Xeon Processor 5500 Series Low Power SKU Thermal Profile ............................ 97 6-5 Intel Xeon Processor L5518 Thermal Profile .......................................................... 99 6-6 Intel Xeon Processor L5508 Thermal Profile ........................................................ 101 6-7 Case Temperature (TCASE) Measurement Location .............................................. 102 6-8 Frequency and Voltage Ordering........................................................................ 104 6-9 Ping()............................................................................................................ 108 6-10 Ping() Example ............................................................................................... 108 6-11 GetDIB()........................................................................................................ 109 6-12 Device Info Field Definition ............................................................................... 109 6-13 Revision Number Definition............................................................................... 109 6-14 GetTemp() ..................................................................................................... 110 6-15 GetTemp() Example......................................................................................... 110 6-16 PCI Configuration Address ................................................................................ 111 6-17 PCIConfigRd()................................................................................................. 112 6-18 PCIConfigWr() ................................................................................................ 114 6-19 Thermal Status Word....................................................................................... 116 6-20 Thermal Data Configuration Register.................................................................. 117 6-21 Machine Check Read MbxSend() Data Format...................................................... 117 6-22 ACPI T-state Throttling Control Read / Write Definition ......................................... 119 6-23 MbxSend() Command Data Format.................................................................... 120 6-24 MbxSend() ..................................................................................................... 120 6-25 MbxGet() ....................................................................................................... 122 6-26 Temperature Sensor Data Format...................................................................... 126 6-27 PECI Power-up Timeline ................................................................................... 128 7-1 PROCHOT# POC Timing Requirements ............................................................... 132 7-2 Power States .................................................................................................. 133 8-1 Boxed Active Heat Sink .................................................................................... 138 8-2 Boxed Passive / Active Combination Heat Sink (With Removable Fan) .................... 138 8-3 Boxed Passive/Active Combination Heat Sink (with Fan Removed) ......................... 139 8-4 Intel Boxed 25.5 mm Tall Passive Heat Sink Solution ........................................... 139 8-5 Top Side Baseboard Keep-Out Zones ................................................................. 141 8-6 Top Side Baseboard Mounting-Hole Keep-Out Zones ............................................ 142 8-7 Bottom Side Baseboard Keep-Out Zones ............................................................ 143 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 5 8-8 Primary and Secondary Side 3D Height Restriction Zones......................................144 8-9 Volumetric Height Keep-Ins...............................................................................145 8-10 Volumetric Height Keep-Ins...............................................................................146 8-11 4-Pin Fan Cable Connector (For Active Heat Sink) ................................................147 8-12 4-Pin Base Baseboard Fan Header (For Active Heat Sink) ......................................148 8-13 Thermal Solution Installation.............................................................................150 8-14 Fan Cable Connector Pin Out For 4-Pin Active Thermal Solution..............................151 Tables 1-1 Intel® Xeon® Processor 5500 Series Feature Set Overview ....................................10 1-2 References........................................................................................................12 2-1 Processor Power Supply Voltages1 .......................................................................15 2-2 Voltage Identification Definition ...........................................................................17 2-3 Power-On Configuration (POC[7:0]) Decode ..........................................................22 2-4 VTT Voltage Identification Definition.....................................................................23 2-5 Signal Groups ...................................................................................................23 2-6 Signals With On-Die Termination (ODT) ................................................................25 2-7 Processor Absolute Minimum and Maximum Ratings ...............................................27 2-8 Voltage and Current Specifications .......................................................................27 2-9 VCC Static and Transient Tolerance.....................................................................30 2-10 VCC Overshoot Specifications ..............................................................................31 2-11 VTT Static and Transient Tolerance .....................................................................37 2-12 DDR3 Signal Group DC Specifications ...................................................................39 2-13 PECI DC Electrical Limits.....................................................................................40 2-14 RESET# Signal DC Specifications .........................................................................41 2-15 TAP Signal Group DC Specifications......................................................................41 2-16 PWRGOOD Signal Group DC Specifications ............................................................41 2-17 Control Sideband Signal Group DC Specifications ...................................................42 3-1 Processor Loading Specifications..........................................................................47 3-2 Package Handling Guidelines ...............................................................................47 3-3 Processor Materials ............................................................................................48 4-1 Land Listing by Land Name .................................................................................49 4-2 Land Listing by Land Number ..............................................................................67 5-1 Signal Definitions...............................................................................................85 6-1 Intel® Xeon® Processor W5580 Thermal Specifications..........................................91 6-2 Intel Xeon Processor W5580 Thermal Profile..........................................................92 6-3 Intel Xeon Processor 5500 Series Advanced SKU Thermal Specifications....................92 6-4 Intel Xeon Processor 5500 Series Advanced SKU Thermal Profile A ...........................94 6-5 Intel Xeon Processor 5500 Series Advanced SKU Thermal Profile B ...........................94 6-6 Intel Xeon Processor 5500 Series Standard/Basic SKUs Thermal Specifications...........95 6-7 Intel Xeon Processor 5500 Series Standard/Basic SKUs Thermal Profile.....................96 6-8 Intel Xeon Processor 5500 Series Low Power SKU Thermal Specifications ..................96 6-9 Intel Xeon Processor 5500 Series Low Power SKU Thermal Profile ............................98 6-10 Intel Xeon Processor L5518 Thermal Specifications.................................................98 6-11 Intel Xeon Processor L5518 Thermal Profile.........................................................100 6-12 Intel Xeon Processor L5508 Thermal Specifications...............................................100 6-13 Intel Xeon Processor L5508 Thermal Profile.........................................................101 6-14 Summary of Processor-specific PECI Commands ..................................................107 6-15 GetTemp() Response Definition .........................................................................111 ® ® 6 Intel Xeon Processor 5500 Series Datasheet, Volume 1 6-16 PCIConfigRd() Response Definition .................................................................... 112 6-17 PCIConfigWr() Device/Function Support ............................................................. 113 6-18 PCIConfigWr() Response Definition .................................................................... 114 6-19 Mailbox Command Summary ............................................................................ 115 6-20 Counter Definition ........................................................................................... 116 6-21 Machine Check Bank Definitions ........................................................................ 118 6-22 ACPI T-state Duty Cycle Definition..................................................................... 119 6-23 MbxSend() Response Definition......................................................................... 121 6-24 MbxGet() Response Definition ........................................................................... 122 6-25 Domain ID Definition ....................................................................................... 124 6-26 Multi-Domain Command Code Reference ............................................................ 124 6-27 Completion Code Pass/Fail Mask........................................................................ 124 6-28 Device Specific Completion Code (CC) Definition.................................................. 125 6-29 Originator Response Guidelines ......................................................................... 125 6-30 Error Codes and Descriptions ............................................................................ 127 6-31 PECI Client Response During Power-Up (During ‘Data Not Ready’) ......................... 127 6-32 Power Impact of PECI Commands versus C-states ............................................... 129 6-33 PECI Client Response During S1 ........................................................................ 129 7-1 Power On Configuration Signal Options............................................................... 131 7-2 Coordination of Thread Power States at the Core Level......................................... 133 7-3 Processor C-State Power Specifications .............................................................. 135 7-4 Processor S-States .......................................................................................... 136 8-1 PWM Fan Frequency Specifications For 4-Pin Active Thermal Solution ..................... 151 8-2 Fan Specifications For 4-Pin Active Thermal Solution ............................................ 151 8-3 Fan Cable Connector Pin Out for 4-Pin Active Thermal Solution.............................. 151 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 7 Revision History Document Revision Description Date Number Number 321321 001 • Initial release March 2009 321321 002 • Added Section 1.3: Statement of Volatility June 2011 § ® ® 8 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Introduction 1 Introduction ® ® The Intel Xeon processor 5500 series is the first-generation server/workstation multi-core processor to implement key new technologies: • Integrated Memory Controller ® • Point-to-point link interface based on Intel QuickPath Technology The processor is optimized for performance with the power efficiencies of a low-power microarchitecture to enable smaller, quieter systems. This document provides DC electrical specifications, differential signaling specifications, pinout and signal definitions, package mechanical specifications and thermal requirements, and additional features pertinent to implementation and operation of the ® ® processor. For information on register descriptions, refer to the Intel Xeon Processor 5500 Series Datasheet, Volume 2. Intel Xeon processor 5500 series are multi-core processors, based on 45 nm process technology. The processor family features a range of thermal design power (TDP) envelopes from 38W TDP up to 130W TDP. These processors feature two Intel QuickPath Interconnect point-to-point links capable of up to 6.4 GT/s, up to 8 MB of shared cache, and an Integrated Memory Controller. The processors support all the existing Streaming SIMD Extensions 2 (SSE2), Streaming SIMD Extensions 3 (SSE3) and Streaming SIMD Extensions 4 (SSE4). The processors support several Advanced ® ® Technologies: Execute Disable Bit, Intel 64 Technology, Enhanced Intel SpeedStep ® ® ® Technology, Intel Virtualization Technology (Intel VT), Intel Hyper-Threading ® ® ® Technology (Intel HT Technology), and Intel Turbo Boost Technology (Intel TBT). The Intel Xeon processor 5500 series family supports multiple platform segments. ® ® • 2-Socket Workstation Platforms support Intel Xeon Processor W5580, a 130W Thermal Design Power (TDP) SKU. These platforms provide optimal overall performance and reliability, in addition to high-end graphics support. Note, specific platform usage conditions apply when implementing these processors. • 2-Socket High Performance Server and High Performance Computing (HPC) Platforms support Intel Xeon processor 5500 series Advanced SKU (95W TDP). These platforms provide optimal overall performance. • 2-Socket Volume Server Platforms support Intel Xeon processor 5500 series Standard/Basic SKUs (80W TDP). These platforms provide optimal performance per watt for rack-optimized platforms. • Ultra Dense Platforms implement Intel Xeon processor 5500 series Low Power SKU (60W TDP). These processors are intended for dual-processor server blades and embedded servers. ® ® •Intel Xeon Processor L5518 with 60W TDP and elevated case temperatures. The elevated case temperatures are intended to meet the short-term thermal profile requirements of NEBS Level 3. These 2-Socket processors are ideal for thermally- constrained form factors in embedded servers, comms and storage markets. ® ® •Intel Xeon Processor L5508 with 38W TDP and elevated case temperatures. The elevated case temperatures are intended to meet the short-term thermal profile requirements of NEBS Level 3. These 2-Socket processors are ideal for thermally- constrained form factors in embedded servers, comms and storage markets. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 9 Introduction • 1-Socket Workstation Platforms support Intel Xeon processor 5500 series SKUs. These platforms enable a wide range of options for either the performance, power, or cost sensitive customer. ® 5520 chipset and Note: All references to “chipset” in this document pertain to the Intel ® Intel 5500 chipset, unless specifically stated otherwise. Table 1-1. Intel® Xeon® Processor 5500 Series Feature Set Overview Feature Intel Xeon Processor 5500 Series Cache Sizes - Instruction Cache = 32 KB, per core - Data Cache = 32 KB, per core - 256 KB Mid-Level Cache per core - 8 MB shared among cores (up to 4) Data Transfer Rate Two (2) full-width Intel QuickPath Interconnect links, up to 6.4 GT/s in each direction Multi-Core Support Up to 4 Cores per processor Dual Processor Support Up to 2 processors per platform Package 1366-land FCLGA 1.1 Terminology A ‘#’ symbol after a signal name refers to an active low signal, indicating a signal is in the active state when driven to a low level. For example, when RESET# is low, a reset has been requested. A ‘_N’ and ‘_P’ after a signal name refers to a differential pair. Commonly used terms are explained here for clarification: • 1366-land FC-LGA package — The Intel Xeon processor 5500 series is available in a Flip-Chip Land Grid Array (FC-LGA) package, consisting of processor mounted on a land grid array substrate with an integrated heat spreader (IHS). • DDR3 — Double Data Rate 3 synchronous dynamic random access memory (SDRAM) is the name of the new DDR memory standard that is being developed as the successor to DDR2 SDRAM. • Enhanced Intel SpeedStep Technology — Enhanced Intel SpeedStep Technology allows the operating system to reduce power consumption when performance is not needed. • Intel Turbo Boost Technology — Intel Turbo Boost Technology is a way to automatically run the processor core faster than the marked frequency if the part is operating under power, temperature, and current specifications limits of the Thermal Design Power (TDP). This results in increased performance of both single and multi-threaded applications. • Execute Disable Bit — Execute Disable allows memory to be marked as executable or non-executable, when combined with a supporting operating system. If code attempts to run in non-executable memory the processor raises an error to the operating system. This feature can prevent some classes of viruses or worms that exploit buffer over run vulnerabilities and can thus help improve the overall ® security of the system. See the Intel 64 and IA-32 Architecture Software Developer's Manuals for more detailed information. • Functional Operation — Refers to the normal operating conditions in which all processor specifications, including DC, AC, signal quality, mechanical, and thermal, are satisfied. ® ® 10 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Introduction • Intel Xeon Processor 5500 Series — Includes processor substrate and integrated heat spreader (IHS). • Integrated Memory Controller (IMC) — As the term implies, the Memory Controller is integrated on the processor die. ® • Intel QuickPath Interconnect (Intel QPI) — A cache-coherent, link-based Interconnect specification for Intel processors, chipsets, and I/O bridge components. ® • Intel 64 Architecture — An enhancement to Intel's IA-32 architecture, allowing the processor to execute operating systems and applications written to take ® advantage of Intel 64. ® • Intel Virtualization Technology (Intel VT) — A set of hardware enhancements to Intel server and client platforms that can improve virtualization solutions. VT provides a foundation for widely-deployed virtualization solutions and enables more robust hardware assisted virtualization solution. • Integrated Heat Spreader (IHS) — A component of the processor package used to enhance the thermal performance of the package. Component thermal solutions interface with the processor at the IHS surface. • Jitter — Any timing variation of a transition edge or edges from the defined Unit Interval (UI). • LGA1366 Socket — The 1366-land FC-LGA package mates with the system board through this surface mount, 1366-contact socket. • Server SKU — A processor Stock Keeping Unit (SKU) to be installed in either server or workstation platforms. Electrical, power and thermal specifications for these SKU’s are based on specific use condition assumptions. Server processors may be further categorized as Advanced, Standard/Basic, and Low Power SKUs. For further details on use condition assumptions, please refer to the latest Product Release Qualification (PRQ) Report available via your Customer Quality Engineer (CQE) contact. • Storage Conditions — Refers to a non-operational state. The processor may be installed in a platform, in a tray, or loose. Processors may be sealed in packaging or exposed to free air. Under these conditions, processor lands should not be connected to any supply voltages, have any I/Os biased, or receive any clocks. • Unit Interval (UI) — Signaling convention that is binary and unidirectional. In this binary signaling, one bit is sent for every edge of the forwarded clock, whether it be a rising edge or a falling edge. If a number of edges are collected at instances t , t , t ,...., t then the UI at instance “n” is defined as: 1 2 n k UI = t - t n n n - 1 • Workstation SKU — A processor SKU to be installed in workstation platforms only. Electrical, power and thermal specifications for these processors have been developed based on Intel’s reliability goals at a reference use condition. In addition, the processor validation and production test conditions have been optimized based on these conditions. Operating “Workstation” processors in a server environment or other application, could impact reliability performance, which means Intel’s reliability goals may not be met. For further details on use condition assumptions or reliability performance, please refer to the latest Product Release Qualification (PRQ) Report available via your Customer Quality Engineer (CQE) contact. • NEBS — Network Equipment Building System. NEBS is the most common set of environmental design guidelines applied to telecommunications equipment in the United States. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 11 Introduction 1.2 References Platform designers are strongly encouraged to maintain familiarity with the most up-to- date revisions of processor and platform collateral. Table 1-2. References Document Location Notes ® AP-485, Intel Processor Identification and the CPUID Instruction 241618 1 1 ® Intel 64 and IA-32 Architecture Software Developer's Manual 253665 • Volume 1: Basic Architecture 253666 • Volume 2A: Instruction Set Reference, A-M 253667 • Volume 2B: Instruction Set Reference, N-Z 253668 • Volume 3A: System Programming Guide, Part 1 253669 • Volume 3B: Systems Programming Guide, Part 2 ® Intel 64 and IA-32 Architectures Optimization Reference Manual 248966 1 ® Intel Virtualization Technology Specification for Directed I/O D51397-001 1 Architecture Specification ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 2 321322 1 Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical 321323 1 Design Guide ® ® Intel Xeon Processor 5500 Series Specification Update 321324 1 Entry-Level Electronics-Bay Specifications: A Server System www.ssiforum.org Infrastructure (SSI) Specification for Entry Pedestal Servers and Workstations ACPI Specifications www.acpi.info Notes: 1. Document is available publicly at http://www.intel.com. 1.3 Statement of Volatility No Intel Xeon processor 5500 series product family processors retain any end user data when powered down and/or when the parts are physically removed from the socket. § ® ® 12 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications ® ® 2 Intel Xeon Processors 5500 Series Electrical Specifications 2.1 Processor Signaling Intel Xeon processor 5500 series include 1366 lands, which utilize various signaling technologies. Signals are grouped by electrical characteristics and buffer type into various signal groups. These include Intel QuickPath Interconnect, DDR3 (Reference Clock, Command, Control and Data), Platform Environmental Control Interface (PECI), Processor Sideband, System Reference Clock, Test Access Port (TAP), and Power/Other signals. Refer to Table 2-5 for details. Detailed layout, routing, and termination guidelines corresponding to these signal groups can be found in the applicable platform design guide (Refer to Section 1.2). Intel strongly recommends performing analog simulations of all interfaces. Please refer to Section 1.2 for signal integrity model availability. ® 2.1.1 Intel QuickPath Interconnect Intel Xeon processor 5500 series provide two Intel QuickPath Interconnect ports for high speed serial transfer between other enabled components. Each port consists of two uni-directional links (for transmit and receive). A differential signaling scheme is utilized, which consists of opposite-polarity (D_P, D_N) signal pairs. . On-die termination (ODT) is included on the processor silicon and terminated to V SS Intel chipsets also provide ODT, thus eliminating the need to terminate on the system board. Figure 2-1 illustrates the active ODT. Figure 2-1. Active ODT for a Differential Link Example T R X Signal X Signal R R R R TT TT TT TT 2.1.2 DDR3 Signal Groups The memory interface utilizes DDR3 technology, which consists of numerous signal groups. These include: Reference Clocks, Command Signals, Control Signals, and Data Signals. Each group consists of numerous signals, which may utilize various signaling technologies. Please refer to Table 2-5 for further details. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 13 Intel® Xeon® Processors 5500 Series Electrical Specifications 2.1.3 Platform Environmental Control Interface (PECI) PECI is an Intel proprietary interface that provides a communication channel between Intel processors and chipset components to external thermal monitoring devices. The Intel Xeon Processor 5500 Series contains a Digital Thermal Sensor (DTS) that reports a relative die temperature as an offset from Thermal Control Circuit (TCC) activation temperature. Temperature sensors located throughout the die are implemented as analog-to-digital converters calibrated at the factory. PECI provides an interface for external devices to read processor temperature, perform processor manageability functions, and manage processor interface tuning and diagnostics. Please refer to Section 6 for processor specific implementation details for PECI. . The set of DC electrical The PECI interface operates at a nominal voltage set by V TTD specifications shown in Table 2-13 is used with devices normally operating from a V TTD interface supply. 2.1.3.1 Input Device Hysteresis The PECI client and host input buffers must use a Schmitt-triggered input design for improved noise immunity. Please refer to Figure 2-2 and Table 2-13. Figure 2-2. Input Device Hysteresis V TTD Maximum V PECI High Range P Minimum V P Minimum Valid Input Hysteresis Signal Range Maximum V N Minimum V PECI Low Range N PECI Ground 2.1.4 Processor Sideband Signals Intel Xeon processor 5500 series include sideband signals that provide a variety of functions. Details can be found in Table 2-5 and the applicable platform design guide. All Asynchronous Processor Sideband signals are required to be asserted/deasserted for at least eight BCLKs in order for the processor to recognize the proper signal state. See Table 2-17 for DC specifications. 2.1.5 System Reference Clock The processor core, processor uncore, Intel QuickPath Interconnect link, and DDR3 memory interface frequencies are generated from BCLK_DP and BCLK_DN signals. There is no direct link between core frequency and Intel QuickPath Interconnect link frequency (for example, no core frequency to Intel QuickPath Interconnect multiplier). The processor maximum core frequency, Intel QuickPath Interconnect link frequency ® ® 14 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications and DDR3 memory frequency are set during manufacturing. It is possible to override the processor core frequency setting using software. This permits operation at lower core frequencies than the factory set maximum core frequency. The processor core frequency is configured during reset by using values stored within the device during manufacturing. The stored value sets the lowest core multiplier at which the particular processor can operate. If higher speeds are desired, the appropriate ratio can be configured via the IA32_PERF_CTL MSR. Clock multiplying within the processor is provided by the internal phase locked loop (PLL), which requires a constant frequency BCLK_DP, BCLK_DN input, with exceptions for spread spectrum clocking. 2.1.6 Test Access Port (TAP) Signals Due to the voltage levels supported by other components in the Test Access Port (TAP) logic, it is recommended that the processor(s) be first in the TAP chain and followed by any other components within the system. A translation buffer should be used to connect to the rest of the chain unless one of the other components is capable of accepting an input of the appropriate voltage. Similar considerations must be made for TCK, TDO, TMS, and TRST#. Two copies of each signal may be required with each driving a different voltage level. Processor TAP signal DC specifications can be found in Table 2-17. Note: While TDI, TMS and TRST# do not include On-Die Termination (ODT), these signals are weakly pulled-up via a 1-5 kΩ resistor to V . TT Note: While TCK does not include ODT, this signal is weakly pulled-down via a 1-5 kΩ resistor to V . SS 2.1.7 Power / Other Signals Processors also include various other signals including power/ground, sense points, and analog inputs. Details can be found in Table 2-5 and the applicable platform design guide. Table 2-1 outlines the required voltage supplies necessary to support Intel Xeon processor 5500 series. 1 Table 2-1. Processor Power Supply Voltages Power Rail Nominal Voltage Notes See Table 2-9; Each processor includes a dedicated VR11.1 regulator. V CC Figure 2-3 1.80 V Each processor includes dedicated V and PLL circuits. V CCPLL CCPLL 1.50 V Each processor and DDR3 stack shares a dedicated voltage regulator. V DDQ Each processor includes a dedicated VR11.0 regulator. V = V + V ; P1V1_Vtt is VID[4:2] controlled, TT TTA TTD See Table 2-11; V , V VID range is 1.0255-1.2000 V; 20 mV offset (see Table 2-4); V TTA TTD TT Figure 2-10 represents a typical voltage. V and V loadlines represent a TT_MIN TT_MAX 31.5 mV offset from V (typ). TT Note: 1. Refer to Table 2-8 for voltage and current specifications. ® ® Further platform and processor power delivery details can be found in the Intel Xeon Processor 5500 Platform Design Guide (PDG). ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 15 Intel® Xeon® Processors 5500 Series Electrical Specifications 2.1.7.1 Power and Ground Lands For clean on-chip power distribution, processors include lands for all required voltage supplies. These include: •210 each V (271 ea. V ) lands must be supplied with the voltage determined by CC SS the VID[7:0] signals. Table 2-2 defines the voltage level associated with each core VID pattern. Table 2-9 and Figure 2-3 represent V static and transient limits. CC •3 each V lands, connected to a 1.8 V supply, power the Phase Lock Loop (PLL) CCPLL clock generation circuitry. An on-die PLL filter solution is implemented within the Intel Xeon processor 5500 series. • 45 each V (17 ea. V ) lands, connected to a 1.50 V supply, provide power to DDQ SS the processor DDR3 interface. This supply also powers the DDR3 memory subsystem. •7 each V (5 ea. V ) and 26 ea. V (17 ea. V ) lands must be supplied with TTA SS TTD SS the voltage determined by the VTT_VID[4:2] signals. Coupled with a 20 mV offset, this corresponds to a VTT_VID pattern of ‘010xxx10’. Table 2-4 specifies the voltage levels associated with each VTT VID pattern. Table 2-11 and Figure 2-10 _ represent V static and transient limits. TT All V , V V V , and V lands must be connected to their respective CC CCPLL, DDQ, TTA TTD processor power planes, while all V lands must be connected to the system ground SS ® ® plane. Refer to the Intel Xeon Processor 5500 Platform Design Guide (PDG) for decoupling, voltage plane and routing guidelines for each power supply voltage. 2.1.7.2 Decoupling Guidelines Due to its large number of transistors and high internal clock speeds, the Intel Xeon processor 5500 series is capable of generating large current swings between low and full power states. This may cause voltages on power planes to sag below their ), such minimum values if bulk decoupling is not adequate. Larger bulk storage (C BULK as electrolytic capacitors, supply current during longer lasting changes in current demand, for example coming out of an idle condition. Similarly, they act as a storage well for current when entering an idle condition from a running condition. Care must be taken in the baseboard design to ensure that the voltages provided to the processor remains within the specifications listed in Table 2-8. Failure to do so can result in timing violations or reduced lifetime of the processor. 2.1.7.3 Processor V Voltage Identification (VID) Signals CC The voltage set by the VID signals is the maximum reference voltage regulator (VR) output to be delivered to the processor V lands. VID signals are CMOS push/pull CC outputs. Please refer to Table 2-17 for the DC specifications for these and other processor sideband signals. Individual processor VID values may be calibrated during manufacturing such that two processor units with the same core frequency may have different default VID settings. The Intel Xeon processor 5500 series uses eight voltage identification signals, VID[7:0], to support automatic selection of core power supply voltages. Table 2-2 specifies the voltage level corresponding to the state of VID[7:0]. A ‘1’ in this table refers to a high voltage level and a ‘0’ refers to a low voltage level. If the processor socket is empty (SKTOCC# high), or the voltage regulation circuit cannot supply the voltage that is requested, the voltage regulator must disable itself. ® ® 16 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications The Intel Xeon processor 5500 series provides the ability to operate while transitioning to an adjacent VID and its associated processor core voltage (V ). This is represented CC by a DC shift in the loadline. It should be noted that a low-to-high or high-to-low voltage state change may result in as many VID transitions as necessary to reach the target core voltage. Transitions above the maximum specified VID are not permitted. Table 2-8 includes VID step sizes and DC shift ranges. Minimum and maximum voltages must be maintained as shown in Table 2-9. The VRM or EVRD utilized must be capable of regulating its output to the value defined by the new VID. DC specifications for dynamic VID transitions are included in Table 2-8 and Table 2-9. Power source characteristics must be guaranteed to be stable whenever the supply to the voltage regulator is stable. Table 2-2. Voltage Identification Definition (Sheet 1 of 5) VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 V CC_MAX 000000 0 0 OFF 000000 0 1 OFF 000000 1 0 1.60000 000000 1 1 1.59375 000001 0 0 1.58750 000001 0 1 1.58125 000001 1 0 1.57500 000001 1 1 1.56875 000010 0 0 1.56250 000010 0 1 1.55625 000010 1 0 1.55000 000010 1 1 1.54375 000011 0 0 1.53750 000011 0 1 1.53125 000011 1 0 1.52500 000011 1 1 1.51875 000100 0 0 1.51250 000100 0 1 1.50625 000100 1 0 1.50000 000100 1 1 1.49375 000101 0 0 1.48750 000101 0 1 1.48125 000101 1 0 1.47500 000101 1 1 1.46875 000110 0 0 1.46250 000110 0 1 1.45625 000110 1 0 1.45000 000110 1 1 1.44375 000111 0 0 1.43750 000111 0 1 1.43125 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 17 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-2. Voltage Identification Definition (Sheet 2 of 5) VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 V CC_MAX 000111 1 0 1.42500 000111 1 1 1.41875 001000 0 0 1.41250 001000 0 1 1.40625 001000 1 0 1.40000 001000 1 1 1.39375 001001 0 0 1.38750 001001 0 1 1.38125 001001 1 0 1.37500 001001 1 1 1.36875 001010 0 0 1.36250 001010 0 1 1.35625 0 0 1 0 1 0 1 0 1.35000 0 0 1 0 1 0 1 1 1.34375 0 0 1 0 1 1 0 0 1.33750 0 0 1 0 1 1 0 1 1.33125 0 0 1 0 1 1 1 0 1.32500 0 0 1 0 1 1 1 1 1.31875 0 0 1 1 0 0 0 0 1.31250 0 0 1 1 0 0 0 1 1.30625 0 0 1 1 0 0 1 0 1.30000 0 0 1 1 0 0 1 1 1.29375 0 0 1 1 0 1 0 0 1.28750 0 0 1 1 0 1 0 1 1.28125 0 0 1 1 0 1 1 0 1.27500 0 0 1 1 0 1 1 1 1.26875 0 0 1 1 1 0 0 0 1.26250 0 0 1 1 1 0 0 1 1.25625 0 0 1 1 1 0 1 0 1.25000 0 0 1 1 1 0 1 1 1.24375 0 0 1 1 1 1 0 0 1.23750 0 0 1 1 1 1 0 1 1.23125 0 0 1 1 1 1 1 0 1.22500 0 0 1 1 1 1 1 1 1.21875 0 1 0 0 0 0 0 0 1.21250 0 1 0 0 0 0 0 1 1.20625 0 1 0 0 0 0 1 0 1.20000 0 1 0 0 0 0 1 1 1.19375 0 1 0 0 0 1 0 0 1.18750 0 1 0 0 0 1 0 1 1.18125 0 1 0 0 0 1 1 0 1.17500 0 1 0 0 0 1 1 1 1.16875 ® ® 18 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-2. Voltage Identification Definition (Sheet 3 of 5) VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 V CC_MAX 0 1 0 0 1 0 0 0 1.16250 0 1 0 0 1 0 0 1 1.15625 0 1 0 0 1 0 1 0 1.15000 0 1 0 0 1 0 1 1 1.14375 0 1 0 0 1 1 0 0 1.13750 0 1 0 0 1 1 0 1 1.13125 0 1 0 0 1 1 1 0 1.12500 0 1 0 0 1 1 1 1 1.11875 0 1 0 1 0 0 0 0 1.11250 0 1 0 1 0 0 0 1 1.10625 0 1 0 1 0 0 1 0 1.10000 0 1 0 1 0 0 1 1 1.09375 0 1 0 1 0 1 0 0 1.08750 0 1 0 1 0 1 0 1 1.08125 0 1 0 1 0 1 1 0 1.07500 0 1 0 1 0 1 1 1 1.06875 0 1 0 1 1 0 0 0 1.06250 0 1 0 1 1 0 0 1 1.05625 0 1 0 1 1 0 1 0 1.05000 0 1 0 1 1 0 1 1 1.04375 0 1 0 1 1 1 0 0 1.03750 0 1 0 1 1 1 0 1 1.03125 0 1 0 1 1 1 1 0 1.02500 0 1 0 1 1 1 1 1 1.01875 0 1 1 0 0 0 0 0 1.01250 0 1 1 0 0 0 0 1 1.00625 0 1 1 0 0 0 1 0 1.00000 0 1 1 0 0 0 1 1 0.99375 0 1 1 0 0 1 0 0 0.98750 0 1 1 0 0 1 0 1 0.98125 0 1 1 0 0 1 1 0 0.97500 0 1 1 0 0 1 1 1 0.96875 0 1 1 0 1 0 0 0 0.96250 0 1 1 0 1 0 0 1 0.95625 0 1 1 0 1 0 1 0 0.95000 0 1 1 0 1 0 1 1 0.94375 0 1 1 0 1 1 0 0 0.93750 0 1 1 0 1 1 0 1 0.93125 0 1 1 0 1 1 1 0 0.92500 0 1 1 0 1 1 1 1 0.91875 0 1 1 1 0 0 0 0 0.91250 0 1 1 1 0 0 0 1 0.90625 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 19 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-2. Voltage Identification Definition (Sheet 4 of 5) VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 V CC_MAX 0 1 1 1 0 0 1 0 0.90000 0 1 1 1 0 0 1 1 0.89375 0 1 1 1 0 1 0 0 0.88750 0 1 1 1 0 1 0 1 0.88125 0 1 1 1 0 1 1 0 0.87500 0 1 1 1 0 1 1 1 0.86875 0 1 1 1 1 0 0 0 0.86250 0 1 1 1 1 0 0 1 0.85625 0 1 1 1 1 0 1 0 0.85000 0 1 1 1 1 0 1 1 0.84375 0 1 1 1 1 1 0 0 0.83750 0 1 1 1 1 1 0 1 0.83125 0 1 1 1 1 1 1 0 0.82500 0 1 1 1 1 1 1 1 0.81875 1 0 0 0 0 0 0 0 0.81250 1 0 0 0 0 0 0 1 0.80625 1 0 0 0 0 0 1 0 0.80000 1 0 0 0 0 0 1 1 0.79375 1 0 0 0 0 1 0 0 0.78750 1 0 0 0 0 1 0 1 0.78125 1 0 0 0 0 1 1 0 0.77500 1 0 0 0 0 1 1 1 0.76875 1 0 0 0 1 0 0 0 0.76250 1 0 0 0 1 0 0 1 0.75625 1 0 0 0 1 0 1 0 0.75000 100010 1 1 0.74375 100011 0 0 0.73750 100011 0 1 0.73125 100011 1 0 0.72500 100011 1 1 0.71875 100100 0 0 0.71250 100100 0 1 0.70625 100100 1 0 0.70000 100100 1 1 0.69375 100101 0 0 0.68750 100101 0 1 0.68125 100101 1 0 0.67500 100101 1 1 0.66875 100110 0 0 0.66250 100110 0 1 0.65625 100110 1 0 0.65000 100110 1 1 0.64375 ® ® 20 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-2. Voltage Identification Definition (Sheet 5 of 5) VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 V CC_MAX 100111 0 0 0.63750 100111 0 1 0.63125 100111 1 0 0.62500 100111 1 1 0.61875 101000 0 0 0.61250 101000 0 1 0.60625 101000 1 0 0.60000 101000 1 1 0.59375 101001 0 0 0.58750 101001 0 1 0.58125 101001 1 0 0.57500 101001 1 1 0.56875 101010 0 0 0.56250 101010 0 1 0.55625 101010 1 0 0.55000 101010 1 1 0.54375 101011 0 0 0.53750 101011 0 1 0.53125 101011 1 0 0.52500 101011 1 1 0.51875 101100 0 0 0.51250 101100 0 1 0.50625 101100 1 0 0.50000 111111 1 0 OFF 111111 1 1 OFF Notes: 1. When the “11111111” VID pattern is observed, or when the SKTOCC# pin is high, the voltage regulator output should be disabled. 2. Shading denotes the expected VID range of the Intel Xeon processor 5500 series. 3. The VID range includes VID transitions that may be initiated by thermal events, Extended HALT state ® transitions (see Section 7.2), higher C-States (see Section 7.2) or Enhanced Intel SpeedStep Technology transitions (see Section 7.5). The Extended HALT state must be enabled for the processor to remain within its specifications. 4. Once the VRM/EVRD is operating after power-up, if either the Output Enable signal is de-asserted or a specific VID off code is received, the VRM/EVRD must turn off its output (the output should go to high impedance) within 500 ms and latch off until power is cycled. 2.1.7.3.1 Power-On Configuration (POC) Logic VID[7:0] signals also serve a second function. During power-up, Power-On Configuration POC[7:0] functionality is multiplexed onto these signals via 1-5 kΩ pull- up or pull down resistors located on the baseboard. These values provide voltage regulator keying (VID[7]), inform the processor of the platforms power delivery capabilities (MSID[2:0]), and program the gain applied to the ISENSE input (CSC[2:0]). Table 2-3 maps VID signals to the corresponding POC functionality. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 21 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-3. Power-On Configuration (POC[7:0]) Decode Function Bits POC Settings Description VR_Key VID[7] 0b for VR11.1 Electronic safety key distinguishing VR11.1 Spare VID[6] 0b (default) Reserved for future use CSC[2:0] VID[5:3] -000 Feature Disabled Current Sensor Configuration (CSC) programs the gain -001 ICC_MAX = 40A applied to the ISENSE A/D 1 -010 ICC_MAX = 50A output. ISENSE data is then -011 ICC_MAX = 80A used to dynamically calculate -100 ICC_MAX = 100A current and power. -101 ICC_MAX = 120A 2 -111 ICC_MAX = 150A MSID[2:0] VID[2:0] -001 38W TDP / 40A ICC_MAX MSID[2:0] signals are provided to indicate the Market Segment -011 60W TDP / 80A ICC_MAX for the processor and may be -100 80W TDP / 100A ICC_MAX used for future processor -101 95W TDP / 120A ICC_MAX compatibility or keying. See -110 130W TDP / 150A ICC_MAX Figure 7-1 for platform timing requirements of the MSID[2:0] signals. Notes: 1. This setting is defined for future use; no specific Intel Xeon processor 5500 series SKU is defined with ICC_MAX = 50A 2. General rule: Set PWM IMON slope to: 900 mV=IMAX, where IMAX =IccMAX with one exception: for Intel Xeon Processor W5580 set IMON slope to 900 mV=180A, but for all other SKUs they have to match, as shown above. Consult your PWM data sheet for the IMON slope setting. Some POC signals include specific timing requirements. Please refer to Section 7.1 for further details. 2.1.7.4 Processor V Voltage Identification (VTT_VID) Signals TT The voltage set by the VTT_VID signals is the typical reference voltage regulator (VR) output to be delivered to the processor V and V lands. It is expected that one TTA TTD regulator will supply all V and V lands. VTT_VID signals are CMOS push/pull TTA TTD outputs. Please refer to Table 2-17 for the DC specifications for these signals. Individual processor VTT_VID values may be calibrated during manufacturing such that two processor units with the same core frequency may have different default VTT_VID settings. The Intel Xeon processor 5500 series utilizes three voltage identification signals to support automatic selection of power supply voltages. These correspond to VTT_VID[4:2]. The V voltage level delivered to the processor lands must also TT encompass a 20 mV offset (See Table 2-4; V ) above the voltage level TT_TYP corresponding to the state of the VTT_VID[7:0] signals (See Table 2-4; VR 11.0 Voltage). Table 2-11 and Figure 2-10 provide the resulting static and transient tolerances. Please note that the maximum and minimum electrical loadlines are defined by a 31.5 mV tolerance band above and below V values. TT_TYP Power source characteristics must be guaranteed to be stable whenever the supply to the voltage regulator is stable. ® ® 22 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-4. V Voltage Identification Definition TT VR 11.0 V TT_TYP VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 Voltage (Voltage + Offset) 01 0 0 0 0 1 0 1.200 V 1.220 V 01 0 0 0 1 1 0 1.175 V 1.195 V 01 0 0 1 0 1 0 1.150 V 1.170 V 01 0 0 1 1 1 0 1.125 V 1.145 V 01 0 1 0 0 1 0 1.100 V 1.120 V 01 0 1 0 1 1 0 1.075 V 1.095 V 01 0 1 1 0 1 0 1.050 V 1.070 V 01 0 1 1 1 1 0 1.025 V 1.045 V 2.1.8 Reserved or Unused Signals All Reserved (RSVD) signals must remain unconnected. Connection of these signals to V , V , V , V , V , or any other signal (including each other) can result in CC TTA TTD DDQ SS component malfunction or incompatibility with future processors. See Section 4 for the land listing and the location of all Reserved signals. For reliable operation, connect unused inputs or bidirectional signals to an appropriate signal level. Unused Intel QuickPath Interconnect input and output pins can be left floating. Unused active high inputs should be connected through a resistor to ground ). Unused outputs can be left unconnected; however, this may interfere with some (V SS TAP functions, complicate debug probing, and prevent boundary scan testing. A resistor must be used when tying bidirectional signals to power or ground. When tying any signal to power or ground, including a resistor will also allow for system testability. Resistor values should be within ± 20% of the impedance of the baseboard trace, unless otherwise noted in the appropriate platform design guidelines. TAP signals do not include on-die termination, however they may include resistors on package (refer to Section 2.1.6 for details). Inputs and utilized outputs must be terminated on the baseboard. Unused outputs may be terminated on the baseboard or left unconnected. Note that leaving unused outputs unterminated may interfere with some TAP functions, complicate debug probing, and prevent boundary scan testing. 2.2 Signal Group Summary Signals are combined in Table 2-5 by buffer type and characteristics. “Buffer Type” denotes the applicable signaling technology and specifications. Table 2-5. Signal Groups (Sheet 1 of 2) 1 Signal Group Buffer Type Signals Intel QuickPath Interconnect Signals Differential Intel QuickPath Interconnect Input QPI[0/1]_DRX_D[N/P][19:0], QPI[0/1]_CLKRX_DP, QPI[0/1]_CLKRX_DN Differential Intel QuickPath Interconnect Output QPI[0/1]_DTX_D[N/P][19:0], QPI[0/1]_CLKTX_DP, QPI[0/1]_CLKTX_DN Single ended Analog Input QPI[0/1]_COMP 2 DDR3 Reference Clocks Differential Output DDR{0/1/2}_CLK_[P/N][3:0] ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 23 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-5. Signal Groups (Sheet 2 of 2) 1 Signal Group Buffer Type Signals 2 DDR3 Command Signals Single ended CMOS Output DDR{0/1/2}_RAS#, DDR{0/1/2}_CAS#, DDR{0/1/2}_WE#, DDR{0/1/2}_MA[15:0], DDR{0/1/2}_BA[2:0], DDR{0/1/2}_MA_PAR Single ended Asynchronous Output DDR{0/1/2}_RESET# 2 DDR3 Control Signals Single ended CMOS Output DDR{0/1/2}_CS#[7:0], DDR{0/1/2}_ODT[5:0], DDR{0/1/2}_CKE[3:0] Single ended Analog Input DDR_VREF, DDR_COMP[2:0] 2 DDR3 Data Signals Single ended CMOS Input/Output DDR{0/1/2}_DQ[63:0], DDR{0/1/2}_ECC[7:0] Differential CMOS Input/Output DDR{0/1/2}_DQS_[N/P][17:0] Single ended Asynchronous Input DDR{0/1/2}_PAR_ERR#[2:0], DDR_THERM# Platform Environmental Control Interface (PECI) Single ended Asynchronous Input/Output PECI Processor Sideband Signals Single ended GTL Input/Output BPM#[7:0], CAT_ERR# Single ended Asynchronous Input PECI_ID# Single ended Asynchronous GTL Output PRDY#, THERMTRIP# Single ended Asynchronous GTL Input PREQ# Single ended Asynchronous GTL Input/Output PROCHOT# Single ended Asynchronous CMOS Output PSI# Single ended CMOS Output VID[7:6], VID[5:3]/CSC[2:0], VID[2:0]/MSID[2:0], VTT_VID[4:2] System Reference Clock Differential Input BCLK_DP, BCLK_DN Test Access Port (TAP) Signals Differential CMOS Output BCLK_ITP_DP, BCLK_ITP_DN Single ended Input TCK, TDI, TMS, TRST# Single ended GTL Output TDO PWRGOOD Signals Single ended Asynchronous Input CCPWRGOOD, VDDPWRGOOD, VTTPWRGOOD RESET Signal Single ended Asynchronous Input RESET# Power/Other Signals Power / Ground V , V , V , V , V , V CC CCPLL DDQ TTA TTD SS Analog Input COMP0, ISENSE Sense Points VCCSENSE, VSSSENSE, VSS_SENSE_VTTD, VTTD_SENSE Other SKTOCC#, DBR# ® ® 24 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Notes: 1. Refer to Section 4 for land assignments and Section 5 for signal definitions. 2. DDR{0/1/2} refers to DDR3 Channel 0, DDR3 Channel1 and DDR3 Channel 2. Signals that include on-die termination (ODT) are listed in Table 2-6. Table 2-6. Signals With On-Die Termination (ODT) 1 Intel QuickPath Interface Signal Group QPI[1:0]_DRX_DP[19:0], QPI[1:0]_DRX_DN[19:0], QPI[1:0]_TRX_DP[19:0], QPI[1:0]_TRX_DN[19:0], QPI[0/1]_CLKRX_D[N/P], QPI[0/1]_CLKTX_D[N/P] 2 DDR3 Signal Group DDR{0/1/2}_DQ[63:0], DDR{0/1/2}_DQS_[N/P][17:0], DDR{0/1/2}_ECC[7:0], 3 DDR{0/1/2}_PAR_ERR#[2:0] Processor Sideband Signal Group 6 7 6 BPM#[7:0] , PECI_ID# , PREQ# Test Access Port (TAP) Signal Group 4 5 5 5 TCK , TDI , TMS , TRST# 8 Power/Other Signal Group VCCPWRGOOD, VDDPWRGOOD, VTTPWRGOOD Notes: 1. Unless otherwise specified, signals have ODT in the package with a 50 Ω pull-down to V . SS 2. Unless otherwise specified, all DDR3 signals are terminated to V /2. DDQ 3. DDR{0/1/2}_PAR_ERR#[2:0] are terminated to V DDQ. 4. TCK does not include ODT, this signal is weakly pulled-down via a 1-5 kΩ resistor to V . SS 5. TDI, TMS, TRST# do not include ODT, these signals are weakly pulled-up via 1-5kΩ resistor to V . TT 6. BPM[7:0]# and PREQ# signals have ODT in package with 35 Ω pull-ups to V TT. 7. PECI_ID# has ODT in package with a 1-5 kΩ pull-up to V . TT 8. VCCPWRGOOD, VDDPWRGOOD, and VTTPWRGOOD have ODT in package with a 5-20 kΩ pull-down to V . SS 2.3 Mixing Processors Intel supports dual processor (DP) configurations consisting of processors: 1. from the same power optimization segment 2. that support the same maximum Intel QuickPath Interconnect and DDR3 memory speeds 3. that share symmetry across physical packages with respect to the number of logical processor per package, number of cores per package, number of Intel QuickPath interfaces, and cache topology 4. that have identical Extended Family, Extended Model, Processor Type, Family Code and Model Number as indicated by the function 1 of the CPUID instruction Note: Processors must operate with the same Intel QuickPath Interconnect, DDR3 memory, and core frequency. While Intel does nothing to prevent processors from operating together, some combinations may not be supported due to limited validation, which may result in uncharacterized errata. Coupling this fact with the large number of Intel Xeon processor 5500 series attributes, the following population rules and stepping matrix have been developed to clearly define supported configurations. 1. Processors must be of the same power-optimization segment. This insures processors include the same maximum Intel QuickPath Interconnect and DDR3 operating speeds and cache sizes. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 25 Intel® Xeon® Processors 5500 Series Electrical Specifications 2. Processors must operate at the same core frequency. Note, processors within the same power-optimization segment supporting different maximum core frequencies (for example, a 2.93 GHz / 95 W and 2.66 GHz / 95 W) can be operated within a system. However, both must operate at the highest frequency rating commonly supported. Mixing components operating at different internal clock frequencies is not supported and will not be validated by Intel. 3. Processors must share symmetry across physical packages with respect to the number of logical processors per package, number of cores per package (but not necessarily the same subset of cores within the packages), number of Intel QuickPath Interconnect interfaces, and cache topology. 4. Mixing dissimilar steppings is only supported with processors that have identical Extended Family, Extended Model, Processor Type, Family Code and Model Number as indicated by the function 1 of the CPUID instruction. Mixing processors of different steppings but the same model (as per CPUID instruction) is supported. Details regarding the CPUID instruction are provided in the AP-485, ® Processor Identification and the CPUID Instruction application note and the Intel ® Intel 64 and IA-32 Architectures Software Developer’s Manual, Volume 2A. 5. After AND’ing the feature flag and extended feature flags from the installed processors, any processor whose set of feature flags exactly matches the AND’ed feature flags can be selected by the BIOS as the BSP. If no processor exactly matches the AND’ed feature flag values, then the processor with the numerically lower CPUID should be selected as the BSP. 6. Intel requires that the proper microcode update be loaded on each processor operating within the system. Any processor that does not have the proper microcode update loaded is considered by Intel to be operating out of specification. 7. Customers are fully responsible for the validation of their system configuration. 2.4 Flexible Motherboard Guidelines (FMB) The Flexible Motherboard (FMB) guidelines are estimates of the maximum values the Intel Xeon processor 5500 series will have over certain time periods. The values are only estimates and actual specifications for future processors may differ. Processors may or may not have specifications equal to the FMB value in the foreseeable future. System designers should meet the FMB values to ensure their systems will be compatible with future Intel Xeon processor 5500 series. 2.5 Absolute Maximum and Minimum Ratings Table 2-7 specifies absolute maximum and minimum ratings which lie outside the functional limits of the processor. Only within specified operation limits, can functionality and long-term reliability be expected. At conditions outside functional operation condition limits, but within absolute maximum and minimum ratings, neither functionality nor long-term reliability can be expected. If a device is returned to conditions within functional operation limits after having been subjected to conditions outside these limits, but within the absolute maximum and minimum ratings, the device may be functional, but with its lifetime degraded depending on exposure to conditions exceeding the functional operation condition limits. ® ® 26 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications At conditions exceeding absolute maximum and minimum ratings, neither functionality nor long-term reliability can be expected. Moreover, if a device is subjected to these conditions for any length of time then, when returned to conditions within the functional operating condition limits, it will either not function or its reliability will be severely degraded. Although the processor contains protective circuitry to resist damage from static electric discharge, precautions should always be taken to avoid high static voltages or electric fields. Table 2-7. Processor Absolute Minimum and Maximum Ratings 1,2 Symbol Parameter Min Nominal Max Unit Notes Processor core voltage with respect to V -0.300 1.350 V V SS CC Processor PLL voltage with respect to V 1.800 V 4 V SS CCPLL Processor I/O supply voltage for DDR3 1.500 V 4 V DDQ with respect to V SS Processor uncore analog voltage with 0.825 1.350 V 3 V TTA respect to V SS Processor uncore digital voltage with 0.825 1.350 V 3 V TTD respect to V SS Processor case temperature See See °C T CASE Section 6 Section 6 Storage temperature -40 85 °C5,6,7 T STORAGE Analog input voltage with respect to Vss -0.30 1.150 V V ISENSE for sensing Core current consumption Notes: 1. For functional operation, all processor electrical, signal quality, mechanical and thermal specifications must be satisfied. 2. Excessive overshoot or undershoot on any signal will likely result in permanent damage to the processor. 3. V and V should be derived from the same voltage regulator (VR). TTA TTD 4. ± 5% tolerance. 5. Storage temperature is applicable to storage conditions only. In this scenario, the processor must not receive a clock, and no lands can be connected to a voltage bias. Storage within these limits will not affect the long-term reliability of the device. For functional operation, please refer to the processor case temperature specifications. 6. This rating applies to the processor and does not include any tray or packaging. 7. Failure to adhere to this specification can affect the long-term reliability of the processor. 2.6 Processor DC Specifications DC specifications are defined at the processor pads, unless otherwise noted. DC specifications are only valid while meeting specifications for case temperature specified in Section 6), clock frequency, and input voltages. Care should be (T CASE taken to read all notes associated with each specification. Table 2-8. Voltage and Current Specifications (Sheet 1 of 3) Voltage 1 Symbol Parameter Min Typ Max Unit Notes Plane VID V VID Range - 0.750 1.350 V 2,3 CC V Core Voltage V V 3,4,6,7,11 CC CC See Table 2-9 and Figure 2-3 (Launch - FMB) V VID step size during a - ± 6.250 mV 9 VID_STEP transition V PLL Voltage V 0.95*V 1.800 1.05*V V10 CCPLL CCPLL CCPLL CCPLL (DC + AC specification) (Typ) (Typ) ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 27 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-8. Voltage and Current Specifications (Sheet 2 of 3) Voltage 1 Symbol Parameter Min Typ Max Unit Notes Plane V I/O Voltage for DDR3 V 0.95*V 1.500 1.05*V V10 DDQ DDQ DDQ DDQ (DC + AC specification) (Typ) (Typ) VTT_VID V VID Range - 1.045 1.220 V 2,3 TT V Uncore Voltage V See Table 2-11 and Figure 2-10 V 3,5,8,11 TT TT (Launch - FMB) I Max. Processor Current: V 150 A 11 CC_MAX CC ® ® I Intel Xeon Processor CCPLL_MAX V 1.1 A CCPLL I W5580 DDQ_MAX V 9 A DDQ I (TDP = 130W) TT_MAX V 6 A TTA (Launch - FMB) V 22 A TTD Max. Processor Current: V 120 A 11 CC Intel Xeon Processor V 1.1 A CCPLL 5500 Series Advanced V 9 A DDQ SKU V 6 A (TDP = 95W) TTA V 22 A (Launch - FMB) TTD Max. Processor Current: V 100 A 11 CC Intel Xeon Processor V 1.1 A CCPLL 5500 Series V 9 A DDQ Standard/Basic SKU V 6 A (TDP = 80W) TTA V 22 A (Launch - FMB) TTD Max. Processor Current: V 80 A 11 CC Intel Xeon Processor V 1.1 A CCPLL 5500 Series Low Power V 9 A DDQ SKU V 6 A (TDP = 60W) TTA V 20 A (Launch - FMB) TTD Max. Processor Current: V 80 A 11 CC ® ® Intel Xeon Processor V 1.1 A CCPLL L5518 V 9 A DDQ (TDP = 60W) V 6 A TTA (Launch - FMB) V 20 A TTD Max. Processor Current: V 40 A 11 CC ® ® Intel Xeon Processor V 1.1 A CCPLL L5508 V 9 A DDQ (TDP = 38W) V 6 A TTA (Launch - FMB) V 20 A TTD ® ® 28 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-8. Voltage and Current Specifications (Sheet 3 of 3) Voltage 1 Symbol Parameter Min Typ Max Unit Notes Plane I Thermal Design V 110 A 11,12 CC_TDC CC I Current: CCPLL_TDC V 1.1 A CCPLL I Intel Xeon Processor DDQ_TDC V 9 A DDQ I W5580 TT_TDC V 6 A (TDP = 130W) TTA V 22 A (Launch - FMB) TTD Thermal Design V 85 A 11,12 CC Current: V 1.1 A CCPLL Intel Xeon Processor V 9 A DDQ 5500 Series Advanced V 6 A SKU TTA (TDP = 95W) V 22 A TTD (Launch - FMB) Thermal Design V 70 A 11,12 CC Current: V 1.1 A CCPLL Intel Xeon Processor V 9 A DDQ 5500 Series V 6 A Standard/Basic SKU TTA V 22 A (TDP = 80W) TTD (Launch - FMB) Thermal Design V 60 A 11,12 CC Current: V 1.1 A CCPLL Intel Xeon Processor V 9 A DDQ 5500 Series Low Power V 6 A SKU TTA (TDP = 60W) V 20 A TTD (Launch - FMB) Thermal Design V 60 A 11,12 CC Current: V 1.1 A CCPLL Intel Xeon Processor V 9 A DDQ L5518 V 6 A (TDP = 60W) TTA V 20 A (Launch - FMB) TTD Thermal Design V 28 A 11,12 CC Current: V 1.1 A CCPLL Intel Xeon Processor V 9 A DDQ L5508 V 6 A (TDP = 38W) TTA V 20 A (Launch - FMB) TTD I DDR3 System Memory V 1.0 A 13,14 DDQ_S3 DDQ Interface Supply Current in Standby State Notes: 1. Unless otherwise noted, all specifications in this table apply to all processors. These specifications are based on pre-silicon characterization and will be updated as further data becomes available. 2. Individual processor VID and/or VTT_VID values may be calibrated during manufacturing such that two devices at the same speed may have different settings. 3. These voltages are targets only. A variable voltage source should exist on systems in the event that a different voltage is required. 4. The V voltage specification requirements are measured across vias on the platform for the VCCSENSE and CC VSSSENSE pins close to the socket with a 100 MHz bandwidth oscilloscope, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled in the scope probe. 5. The V voltage specification requirements are measured across vias on the platform for the VTTD_SENSE TT and VSS_SENSE_VTTD lands close to the socket with a 100 MHz bandwidth oscilloscope, 1.5 pF maximum probe capacitance, and 1 MΩ minimum impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external noise from the system is not coupled in the scope probe. 6. Refer to Table 2-9 and corresponding Figure 2-3. The processor should not be subjected to any static V CC level that exceeds the V associated with any particular current. Failure to adhere to this specification CC_MAX can shorten processor lifetime. 7. Minimum V and maximum I are specified at the maximum processor case temperature (T ) shown in CC CC CASE Table 6-1. I is specified at the relative V point on the V load line. The processor is capable of CC_MAX CC_MAX CC ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 29 Intel® Xeon® Processors 5500 Series Electrical Specifications drawing I for up to 10 ms. Refer to Figure 2-5 through Figure 2-8 for further details on the average CC_MAX processor current draw over various time durations. 8. Refer to Table 2-11 and corresponding Figure 2-10. The processor should not be subjected to any static V TT level that exceeds the V associated with any particular current. Failure to adhere to this specification TT_MAX can shorten processor lifetime. 9. This specification represents the V reduction due to each VID transition. See Section 2.1.7.3. CC 10.Baseboard bandwidth is limited to 20 MHz. 11.FMB is the flexible motherboard guidelines. See Section 2.4 for FMB details. 12.ICC_TDC (Thermal Design Current) is the sustained (DC equivalent) current that the processor is capable of drawing indefinitely and should be used for the voltage regulator temperature assessment. The voltage regulator is responsible for monitoring its temperature and asserting the necessary signal to inform the processor of a thermal excursion. 13.Specification is at T = 50°C. CASE 14.Characterized by design (not tested). Table 2-9. V Static and Transient Tolerance CC 1,2,3,4 I (A) V (V) V (V) V (V) Notes CC CC_MAX CC_TYP CC_MIN 0 VID - 0.000 VID - 0.015 VID - 0.030 5 VID - 0.004 VID - 0.019 VID - 0.034 10 VID - 0.008 VID - 0.023 VID - 0.038 15 VID - 0.012 VID - 0.027 VID - 0.042 20 VID - 0.016 VID - 0.031 VID - 0.046 25 VID - 0.020 VID - 0.035 VID - 0.050 30 VID - 0.024 VID - 0.039 VID - 0.054 35 VID - 0.028 VID - 0.043 VID - 0.058 40 VID - 0.032 VID - 0.047 VID - 0.062 45 VID - 0.036 VID - 0.051 VID - 0.066 50 VID - 0.040 VID - 0.055 VID - 0.070 55 VID - 0.044 VID - 0.059 VID - 0.074 60 VID - 0.048 VID - 0.063 VID - 0.078 65 VID - 0.052 VID - 0.067 VID - 0.082 70 VID - 0.056 VID - 0.071 VID - 0.086 75 VID - 0.060 VID - 0.075 VID - 0.090 80 VID - 0.064 VID - 0.079 VID - 0.094 85 VID - 0.068 VID - 0.083 VID - 0.098 90 VID - 0.072 VID - 0.087 VID - 0.102 95 VID - 0.076 VID - 0.091 VID - 0.106 100 VID - 0.080 VID - 0.095 VID - 0.110 105 VID - 0.084 VID - 0.099 VID - 0.114 110 VID - 0.088 VID - 0.103 VID - 0.118 115 VID - 0.092 VID - 0.107 VID - 0.122 120 VID - 0.096 VID - 0.111 VID - 0.126 125 VID - 0.100 VID - 0.115 VID - 0.130 130 VID - 0.104 VID - 0.119 VID - 0.134 135 VID - 0.108 VID - 0.123 VID - 0.138 140 VID - 0.112 VID - 0.127 VID - 0.142 145 VID - 0.116 VID - 0.131 VID - 0.146 150 VID - 0.120 VID - 0.135 VID - 0.150 Notes: 1. The V and V loadlines represent static and transient limits. Please see Section 2.6.1 for V CC_MIN CC_MAX CC overshoot specifications. ® ® 30 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications 2. This table is intended to aid in reading discrete points on Figure 2-3. 3. The loadlines specify voltage limits at the die measured at the VCC_SENSE and VSS_SENSE lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_SENSE and VSS_SENSE lands. Please refer to the appropriate platform design guide for further details on regulator and decoupling implementations. 4. Processor core current (I ) ranges are valid up to I of the processor SKU as defined in Table 2-8, CC CC_MAX “Voltage and Current Specifications”. 1,2,3,4 Figure 2-3. V Static and Transient Tolerance Loadlines CC Icc [A] 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 VID - 0.000 VID - 0.020 VID - 0.040 VID - 0.060 VID - 0.080 VID - 0.100 VID - 0.120 VID - 0.140 VID - 0.160 VID - 0.180 Notes: 1. The V and V loadlines represent static and transient limits. Please see Section 2.6.1 for V CC_MIN CC_MAX CC overshoot specifications. 2. Refer to Table 2-9 for V Static and Transient Tolerance. CC 3. The loadlines specify voltage limits at the die measured at the VCC_SENSE and VSS_SENSE lands. Voltage regulation feedback for voltage regulator circuits must also be taken from processor VCC_SENSE and VSS_SENSE lands. Please refer to the appropriate platform design guide for further details on regulator and decoupling implementations. 4. Processor core current (I ) ranges are valid up to I of the processor SKU as defined in Table 2-8. CC CC_MAX 2.6.1 V Overshoot Specifications CC The Intel Xeon Processor 5500 Series can tolerate short transient overshoot events where V exceeds the VID voltage when transitioning from a high-to-low current load CC condition. This overshoot cannot exceed VID + V (V is the maximum OS_MAX OS_MAX allowable overshoot above VID). These specifications apply to the processor die voltage as measured across the VCC_SENSE and VSS_SENSE lands. Table 2-10. V Overshoot Specifications CC Symbol Parameter Min Max Units Figure Notes V Magnitude of V overshoot above VID - 50 mV 2-4 OS_MAX CC T Time duration of V overshoot above VID - 25 µs 2-4 OS_MAX CC ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 31 Vcc [V] Intel® Xeon® Processors 5500 Series Electrical Specifications Figure 2-4. V Overshoot Example Waveform CC Example Overshoot Waveform V OS VID + 0.050 VID - 0.000 T OS 0 5 10 15 20 25 Time [us] T : Overshoot time above VID OS V : Overshoot above VID OS Notes: 1. V is the measured overshoot voltage. OS 2. T is the measured time duration above VID. OS 2.6.2 Die Voltage Validation Core voltage (V ) overshoot events at the processor must meet the specifications in CC Table 2-10 when measured across the VCC_SENSE and VSS_SENSE lands. Overshoot events that are < 10 ns in duration may be ignored. These measurements of processor die level overshoot should be taken with a 100 MHz bandwidth limited oscilloscope. ® ® 32 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Voltage [V] Intel® Xeon® Processors 5500 Series Electrical Specifications 1,2 Figure 2-5. Load Current Versus Time (130W TDP Processor) 155 150 145 140 135 130 125 120 115 110 105 0.01 0.1 1 10 100 1000 Time Duration, (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than I . CC_TDC 2. Not 100% tested. Specified by design characterization. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 33 Sustained Current (A) Intel® Xeon® Processors 5500 Series Electrical Specifications 1,2 Figure 2-6. Load Current Versus Time (95W TDP Processor) 125.0 120.0 115.0 110.0 105.0 100.0 95.0 90.0 85.0 80.0 0.01 0.1 1 10 100 1000 Time Duration, (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than I . CC_TDC 2. Not 100% tested. Specified by design characterization. ® ® 34 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Sustained Current (A) Intel® Xeon® Processors 5500 Series Electrical Specifications 1,2 Figure 2-7. Load Current Versus Time (80W TDP Processor) 105 100 95 90 85 80 75 70 65 0.01 0.1 1 10 100 1000 Time Duration, (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than I . CC_TDC 2. Not 100% tested. Specified by design characterization. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 35 Sustained Current (A) Intel® Xeon® Processors 5500 Series Electrical Specifications 1,2 Figure 2-8. Load Current Versus Time (60W TDP Processor) 85 80 75 70 65 60 55 0.01 0.1 1 10 100 1000 Time D uration, (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than I . CC_TDC 2. Not 100% tested. Specified by design characterization. ® ® 36 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Sustained Current (A) Intel® Xeon® Processors 5500 Series Electrical Specifications 1,2 Figure 2-9. Load Current Versus Time (38W TDP Processor) 45 40 35 30 25 20 0.01 0.1 1 10 100 1000 Time Duration, (s) Notes: 1. Processor or voltage regulator thermal protection circuitry should not trip for load currents greater than I . CC_TDC 2. Not 100% tested. Specified by design characterization. Table 2-11. V Static and Transient Tolerance (Sheet 1 of 2) TT 1,2,3,4 I (A) V (V) V (V) V (V) Notes TT TT_Max TT_Typ TT_Min 0 VTT_VID + 0.0315 VTT_VID - 0.0000 VTT_VID - 0.0315 1 VTT_VID + 0.0255 VTT_VID - 0.0060 VTT_VID - 0.0375 2 VTT_VID + 0.0195 VTT_VID - 0.0120 VTT_VID - 0.0435 3 VTT_VID + 0.0135 VTT_VID - 0.0180 VTT_VID - 0.0495 4 VTT_VID + 0.0075 VTT_VID - 0.0240 VTT_VID - 0.0555 5 VTT_VID + 0.0015 VTT_VID - 0.0300 VTT_VID - 0.0615 6 VTT_VID - 0.0045 VTT_VID - 0.0360 VTT_VID - 0.0675 7 VTT_VID - 0.0105 VTT_VID - 0.0420 VTT_VID - 0.0735 8 VTT_VID - 0.0165 VTT_VID - 0.0480 VTT_VID - 0.0795 9 VTT_VID - 0.0225 VTT_VID - 0.0540 VTT_VID - 0.0855 10 VTT_VID - 0.0285 VTT_VID - 0.0600 VTT_VID - 0.0915 11 VTT_VID - 0.0345 VTT_VID - 0.0660 VTT_VID - 0.0975 12 VTT_VID - 0.0405 VTT_VID - 0.0720 VTT_VID - 0.1035 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 37 Sustained Current (A) Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-11. V Static and Transient Tolerance (Sheet 2 of 2) TT 1,2,3,4 I (A) V (V) V (V) V (V) Notes TT TT_Max TT_Typ TT_Min 13 VTT_VID - 0.0465 VTT_VID - 0.0780 VTT_VID - 0.1095 14 VTT_VID - 0.0525 VTT_VID - 0.0840 VTT_VID - 0.1155 15 VTT_VID - 0.0585 VTT_VID - 0.0900 VTT_VID - 0.1215 16 VTT_VID - 0.0645 VTT_VID - 0.0960 VTT_VID - 0.1275 17 VTT_VID - 0.0705 VTT_VID - 0.1020 VTT_VID - 0.1335 18 VTT_VID - 0.0765 VTT_VID - 0.1080 VTT_VID - 0.1395 19 VTT_VID - 0.0825 VTT_VID - 0.1140 VTT_VID - 0.1455 20 VTT_VID - 0.0885 VTT_VID - 0.1200 VTT_VID - 0.1515 21 VTT_VID - 0.0945 VTT_VID - 0.1260 VTT_VID - 0.1575 22 VTT_VID - 0.1005 VTT_VID - 0.1320 VTT_VID - 0.1635 23 VTT_VID - 0.1065 VTT_VID - 0.1380 VTT_VID - 0.1695 24 VTT_VID - 0.1125 VTT_VID - 0.1440 VTT_VID - 0.1755 25 VTT_VID - 0.1185 VTT_VID - 0.1500 VTT_VID - 0.1815 26 VTT_VID - 0.1245 VTT_VID - 0.1560 VTT_VID - 0.1875 27 VTT_VID - 0.1305 VTT_VID - 0.1620 VTT_VID - 0.1935 28 VTT_VID - 0.1365 VTT_VID - 0.1680 VTT_VID - 0.1995 Note: 1. I listed in this table is the sum of I and I . TT TTA TTD 2. This table is intended to aid in reading discrete points on Figure 2-10. 3. The V and V loadlines represent static and transient limits. Each is characterized by a ±31.5 mV TT_MIN TT_MAX offset from V . TT_TYP 4. The loadlines specify voltage limits at the die measured at the VTTD_SENSE and VSS_SENSE_VTTD lands. Voltage regulation feedback for regulator circuits must also be taken from VTTD_SENSE and VSS_SENSE_VTTD lands. ® ® 38 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Figure 2-10. V Static and Transient Tolerance Loadlines TT I [A] TT 0 5 10 15 20 25 0.0500 0.0375 0.0250 0.0125 0.0000 -0.0125 -0.0250 -0.0375 -0.0500 -0.0625 -0.0750 -0.0875 -0.1000 -0.1125 -0.1250 -0.1375 -0.1500 -0.1625 -0.1750 -0.1875 -0.2000 -0.2125 Notes: 1. The V and V loadlines represent static and transient limits. Each is characterized by a ±31.5 mV TT_MIN TT_MAX offset from V . TT_TYP 2. Refer to Table 2-4 for processor VTT_VID information. 3. Refer to Table 2-11 for V Static and Transient Tolerance. TT Table 2-12. DDR3 Signal Group DC Specifications (Sheet 1 of 2) 1 Symbol Parameter Min Typ Max Units Notes V Input Low Voltage 0.43*V V2, IL DDQ V Input High Voltage 0.57*V V3, 4 IH DDQ Output Low Voltage (V / 2)* (R V6 DDQ ON V OL /(R +R )) ON VTT_TERM Output High V - ((V / 2)* V4,6 DDQ DDQ V OH Voltage (R /(R +R )) ON ON VTT_TERM DDR3 Clock Buffer 21 31 Ω 5 R ON On Resistance DDR3 Command 16 24 Ω 5 R Buffer On ON Resistance DDR3 Reset Buffer 25 75 Ω 5 R ON On Resistance DDR3 Control 21 31 Ω 5 R Buffer On ON Resistance DDR3 Data Buffer 21 31 Ω 5 R ON On Resistance On-Die Termination 45 55 Ω 7 Data ODT for Data Signals 90 110 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 39 VTT_VID DevIatIon Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-12. DDR3 Signal Group DC Specifications (Sheet 2 of 2) 1 Symbol Parameter Min Typ Max Units Notes On-Die Termination 60 80 Ω ParErr ODT for Parity Error bits Input Leakage N/A N/A mA I ± 500 LI Current DDR_COMP0 COMP Resistance 99 100 101 Ω 8 DDR_COMP1 COMP Resistance 24.65 24.9 25.15 Ω 8 DDR_COMP2 COMP Resistance 128.7 130 131.3 Ω 8 Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. V is the maximum voltage level at a receiving agent that will be interpreted as a logical low value. IL 3. V is the minimum voltage level at a receiving agent that will be interpreted as a logical high value. IH 4. V and V may experience excursions above V . IH OH DDQ 5. This is the pull down driver resistance. Refer to processor signal integrity models for I/V characteristics. 6. R is the termination on the DIMM and not controlled by the Intel Xeon Processor 5500 Series. VTT_TERM Please refer to the applicable DIMM datasheet. 7. The minimum and maximum values for these signals are programmable by BIOS to one of the pairs. 8. COMP resistance must be provided on the system board with 1% resistors. DDR_COMP[2:0] resistors are to Vss. Table 2-13. PECI DC Electrical Limits 1 Symbol Definition and Conditions Min Max Units Notes V Input Voltage Range -0.150 V + 0.150 V In TTD V Hysteresis 0.100 * V V Hysteresis TTD V Negative-edge threshold voltage 0.275 * V 0.500 * V V2,6 N TTD TTD V Positive-edge threshold voltage 0.550 * V 0.725 * V V2,6 P TTD TTD R Pullup Resistance Pullup N/A 50 Ω (V = 0.75 * V ) OH TTD I High impedance state leakage to Leak+ N/A 50 µA 3 V (V = V ) TTD leak OL I High impedance leakage to GND Leak- N/A 25 µA 3 (V = V ) leak OH C Bus capacitance per node N/A 10 pF 4,5 Bus V Signal noise immunity above Noise 0.100 * V N/A V TTD p-p 300 MHz Note: 1. V supplies the PECI interface. PECI behavior does not affect V min/max specifications. TTD TTD 2. It is expected that the PECI driver will take into account, the variance in the receiver input thresholds and consequently, be able to drive its output within safe limits (-0.150 V to 0.275*V for the low level and TTD 0.725*V to V +0.150 for the high level). TTD TTD 3. The leakage specification applies to powered devices on the PECI bus. 4. One node is counted for each client and one node for the system host. Extended trace lengths might appear as additional nodes. 5. Excessive capacitive loading on the PECI line may slow down the signal rise/fall times and consequently limit the maximum bit rate at which the interface can operate. 6. Please refer to Figure 2-2 for further information. ® ® 40 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-14. RESET# Signal DC Specifications 1 Symbol Parameter Min Typ Max Units Notes V Input Low Voltage 0.60 V V2,3 IL * TTA V Input High Voltage 0.70 V V2,3,5 IH * TTA R Processor Sideband Buffer 10 18 Ω ON On Resistance I Input Leakage Current ± 200 μA4 LI Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. The V referred to in these specifications refers to instantaneous V . TTA TTA 3. Based on a test load of 50 Ω to V . TTA 4. For V between 0 V and V . Measured when the driver is tristated. IN TTA 5. V and V may experience excursions above V . IH OH TT Table 2-15. TAP Signal Group DC Specifications 1 Symbol Parameter Min Typ Max Units Notes V Input Low Voltage 0.40 V V2,3 IL * TTA V Input High Voltage 0.60 V V2,3,5 IH * TTA V Output Low Voltage V * R / V2,6 OL TTA ON (R + R ) ON SYS_TERM V Output High Voltage V V2,5 OH TTA R Processor Sideband Buffer 10 18 Ω ON On Resistance I Input Leakage Current ± 200 μA4 LI Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. The V referred to in these specifications refers to instantaneous V . TTA TTA 3. Based on a test load of 50 Ω to V . TTA 4. For V between 0 V and V . Measured when the driver is tristated. IN TTA 5. V and V may experience excursions above V . IH OH TT 6. R is the termination on the system and is not controlled by the Intel Xeon processor 5500 series SYS_TERM Table 2-16. PWRGOOD Signal Group DC Specifications 1 Symbol Parameter Min Typ Max Units Notes V Input Low Voltage for 0.25 V V2,3 IL * TTA VTTPWRGOOD and VCCPWRGOOD signals V Input Low Voltage for 0.29 V 3 IL VDDPWRGOOD signal V Input High Voltage for 0.75 V V2,3 IH * TTA VTTPWRGOOD and VCCPWRGOOD signals V Input High Voltage for 0.87 V 3 IH VDDPWRGOOD signal ODT On-Die Termination 45 55 R Processor Sideband Buffer 10 18 Ω ON On Resistance I Input Leakage Current ± 200 μA4 LI Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. The V referred to in these specifications refers to instantaneous V . TTA TTA 3. Based on a test load of 50 Ω to V . TTA 4. For V between 0 V and V . Measured when the driver is tristated. IN TTA 5. V and V may experience excursions above V . IH OH TT ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 41 Intel® Xeon® Processors 5500 Series Electrical Specifications Table 2-17. Control Sideband Signal Group DC Specifications 1 Symbol Parameter Min Typ Max Units Notes V Input Low Voltage 0.64 V V2,3 IL * TTA V Input Low Voltage for 0.15 V V2,3 IL * TTA PECI_ID signal V Input High Voltage 0.76 V V2,3 IH * TTA V Input High Voltage for 0.85 V V2,3 IH * TTA PECI_ID signal V Output Low Voltage V * R / V2,4 OL TTA ON (R + R ) ON SYS_TERM V Output High Voltage V V2 OH TTA ODT On-Die Termination 45 55 5 R Processor Sideband Buffer 10 18 Ω ON On Resistance R Buffer On Resistance for 100 Ω ON VID[7:0] I Input Leakage Current ± 200 μA6 LI I Input Leakage Current for ± 50 μA6 LI DDR_THERM# signal COMP0 COMP Resistance 49.4 49.9 50.4 Ω 7 Notes: 1. Unless otherwise noted, all specifications in this table apply to all processor frequencies. 2. The V referred to in these specifications refers to instantaneous V . TTA TTA 3. Based on a test load of 50 Ω to V TTA. 4. R is the termination on the system and is not controlled by the Intel Xeon processor 5500 series. SYS_TERM 5. Applies to all Processor Sideband signals, unless otherwise mentioned in Table 2-5. 6. For V between 0 V and V . Measured when the driver is tristated. IN TTA 7. COMP resistance must be provided on the system board with 1% resistors. See the applicable platform design guide for implementation details. COMP0 resistors are to VSS. § ® ® 42 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Package Mechanical Specifications 3 Package Mechanical Specifications 3.1 Package Mechanical Specifications The processor is packaged in a Flip-Chip Land Grid Array (FC-LGA6) package that interfaces with the motherboard via an LGA1366 socket. The package consists of a processor mounted on a substrate land-carrier. An integrated heat spreader (IHS) is attached to the package substrate and core and serves as the mating surface for processor component thermal solutions, such as a heatsink. Figure 3-1 shows a sketch of the processor package components and how they are assembled together. Refer to the Processors and Socket in the Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guide for complete details on the LGA1366 socket. The package components shown in Figure 3-1 include the following: 1. Integrated Heat Spreader (IHS) 2. Thermal Interface Material (TIM) 3. Processor core (die) 4. Package substrate 5. Capacitors Figure 3-1. Processor Package Assembly Sketch TI TIM M Die IH IHS S Su Sub bs sttrra atte e C Ca apaci pacittor ors s L LG GA1 A 366 Socket S Sy yst ste em m B Boar oard d Note: 1. Socket and motherboard are included for reference and are not part of processor package. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 43 Package Mechanical Specifications 3.1.1 Package Mechanical Drawing The package mechanical drawings are shown in Figure 3-2 and Figure 3-3. The drawings include dimensions necessary to design a thermal solution for the processor. These dimensions include: 1. Package reference with tolerances (total height, length, width, and so forth) 2. IHS parallelism and tilt 3. Land dimensions 4. Top-side and back-side component keep-out dimensions 5. Reference datums 6. All drawing dimensions are in mm. 7. Guidelines on potential IHS flatness variation with socket load plate actuation and installation of the cooling solution is available in the TMDG. ® ® 44 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Package Mechanical Specifications Figure 3-2. Processor Package Drawing (Sheet 1 of 2) ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 45 Package Mechanical Specifications Figure 3-3. Processor Package Drawing (Sheet 2 of 2) ® ® 46 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Package Mechanical Specifications 3.1.2 Processor Component Keep-Out Zones The processor may contain components on the substrate that define component keep-out zone requirements. A thermal and mechanical solution design must not intrude into the required keep-out zones. Do not contact the Test Pad Area with conductive material. Decoupling capacitors are typically mounted to either the topside or land-side of the package substrate. See Figure 3-2 and Figure 3-3 for keep-out zones. The location and quantity of package capacitors may change due to manufacturing efficiencies but will remain within the component keep-in. 3.1.3 Package Loading Specifications Table 3-1 provides load specifications for the processor package. These maximum limits should not be exceeded during heatsink assembly, shipping conditions, or standard use condition. Exceeding these limits during test may result in component failure. The processor substrate should not be used as a mechanical reference or load- bearing surface for thermal solutions. . Table 3-1. Processor Loading Specifications Parameter Maximum Notes Static Compressive Load 890 N [200 lbf] 1, 2, 3, 5 Dynamic Compressive Load 1779 N [400 lbf] [max static 1, 3, 4, 5 compressive + dynamic load] Notes: 1. These specifications apply to uniform compressive loading in a direction normal to the processor IHS. 2. This is the maximum static force that can be applied by the heatsink and Independent Loading Mechanism (ILM). 3. These specifications are based on limited testing for design characterization. Loading limits are for the package constrained by the limits of the processor socket. 4. Dynamic loading is defined as an 11 ms duration average load superimposed on the static load requirement. 5. See Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guide for minimum socket load to engage processor within socket. 3.1.4 Package Handling Guidelines Table 3-2 includes a list of guidelines on package handling in terms of recommended maximum loading on the processor IHS relative to a fixed substrate. These package handling loads may be experienced during heatsink removal. Table 3-2. Package Handling Guidelines Parameter Maximum Recommended Notes Shear 70 lbs - Tensile 25 lbs - Torque 35 in.lbs - 3.1.5 Package Insertion Specifications The processor can be inserted into and removed from a LGA1366 socket 15 times. The socket should meet the LGA1366 requirements detailed in the TMDG. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 47 Package Mechanical Specifications 3.1.6 Processor Mass Specification The typical mass of the processor is 35 grams. This mass [weight] includes all the components that are included in the package. 3.1.7 Processor Materials Table 3-3 lists some of the package components and associated materials. Table 3-3. Processor Materials Component Material Integrated Heat Spreader (IHS) Nickel Plated Copper Substrate Fiber Reinforced Resin Substrate Lands Gold Plated Copper 3.1.8 Processor Markings Figure 3-4 shows the topside markings on the processor. This diagram is to aid in the identification of the processor. Figure 3-4. Processor Top-Side Markings GRP1LINE1 GRP1LINE2 Legend: Mark Text (Engineering Mark): GRP1LINE1: INTEL{M}{C}’YY GRP1LINE2: INTEL CONFIDENTIAL GRP1LINE3: QDF ES XXXXX GRP1LINE4: FORECAST-NAME GRP1LINE5: {FPO} {e4} Legend: Mark Text (Production Mark): GRP1LINE1: INTEL{M}{C}’YY PROC# GRP1LINE2: SUB-BRAND GRP1LINE3: SSPEC XXXXX GRP1LINE4: SPEED/CACHE/INTC GRP1LINE5: {FPO} {e4} G2L1 G3L1 G2L2 G3L2 3.1.9 Processor Land Coordinates Please refer to Figure 3-3 which shows the bottom view of the processor land coordinates. The coordinates are referred to throughout the document to identify processor lands. § ® ® 48 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing 4 Land Listing ® ® 4.1 Intel Xeon Processors 5500 Series Pin Assignments This section provides sorted land list in Table 4-1 and Table 4-2. Table 4-1 is a listing of all processor lands ordered alphabetically by land name. Table 4-2 is a listing of all processor lands ordered by land number. Note: A land name prefixed with a FC denotes a Future Connect land. 4.1.1 Land Listing by Land Name Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 2 of 36) (Sheet 1 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type QPI0_DRX_DN[16] AM41 QPI I BCLK_DN AH35 CMOS I QPI0_DRX_DN[17] AP40 QPI I BCLK_DP AJ35 CMOS I QPI0_DRX_DN[18] AP39 QPI I BCLK_ITP_DN AA4 CMOS O QPI0_DRX_DN[19] AR38 QPI I BCLK_ITP_DP AA5 CMOS O QPI0_DRX_DN[2] AV37 QPI I BPM#[0] B3 GTL I/O QPI0_DRX_DN[3] AY36 QPI I BPM#[1] A5 GTL I/O QPI0_DRX_DN[4] BA37 QPI I BPM#[2] C2 GTL I/O QPI0_DRX_DN[5] AW38 QPI I BPM#[3] B4 GTL I/O QPI0_DRX_DN[6] AY38 QPI I BPM#[4] D1 GTL I/O QPI0_DRX_DN[7] AT39 QPI I BPM#[5] C3 GTL I/O QPI0_DRX_DN[8] AV40 QPI I BPM#[6] D2 GTL I/O QPI0_DRX_DN[9] AU41 QPI I BPM#[7] E2 GTL I/O QPI0_DRX_DP[0] AT37 QPI I CAT_ERR# AC37 GTL I/O QPI0_DRX_DP[1] AU38 QPI I COMP0 AB41 Analog QPI0_DRX_DP[10] AU42 QPI I QPI0_CLKRX_DN AR42 QPI I QPI0_DRX_DP[11] AT43 QPI I QPI0_CLKRX_DP AR41 QPI I QPI0_DRX_DP[12] AT40 QPI I QPI0_CLKTX_DN AF42 QPI O QPI0_DRX_DP[13] AP42 QPI I QPI0_CLKTX_DP AG42 QPI O QPI0_DRX_DP[14] AN43 QPI I QPI0_COMP AL43 Analog QPI0_DRX_DP[15] AN40 QPI I QPI0_DRX_DN[0] AU37 QPI I QPI0_DRX_DP[16] AM42 QPI I QPI0_DRX_DN[1] AV38 QPI I QPI0_DRX_DP[17] AP41 QPI I QPI0_DRX_DN[10] AT42 QPI I QPI0_DRX_DP[18] AN39 QPI I QPI0_DRX_DN[11] AR43 QPI I QPI0_DRX_DP[19] AP38 QPI I QPI0_DRX_DN[12] AR40 QPI I QPI0_DRX_DP[2] AV36 QPI I QPI0_DRX_DN[13] AN42 QPI I QPI0_DRX_DP[3] AW36 QPI I QPI0_DRX_DN[14] AM43 QPI I QPI0_DRX_DP[4] BA36 QPI I QPI0_DRX_DN[15] AM40 QPI I ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 49 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 3 of 36) (Sheet 4 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type QPI0_DRX_DP[5] AW37 QPI I QPI0_DTX_DP[5] AK40 QPI O QPI0_DRX_DP[6] BA38 QPI I QPI0_DTX_DP[6] AH41 QPI O QPI0_DRX_DP[7] AU39 QPI I QPI0_DTX_DP[7] AK42 QPI O QPI0_DRX_DP[8] AW40 QPI I QPI0_DTX_DP[8] AJ43 QPI O QPI0_DRX_DP[9] AU40 QPI I QPI0_DTX_DP[9] AG40 QPI O QPI0_DTX_DN[0] AH38 QPI O QPI1_CLKRX_DN AR6 QPI I QPI0_DTX_DN[1] AG39 QPI O QPI1_CLKRX_DP AT6 QPI I QPI0_DTX_DN[10] AE43 QPI O QPI1_CLKTX_DN AE6 QPI O QPI0_DTX_DN[11] AE41 QPI O QPI1_CLKTX_DP AF6 QPI O QPI0_DTX_DN[12] AC42 QPI O QPI1_COMP AL6 Analog QPI0_DTX_DN[13] AB43 QPI O QPI1_DRX_DN[0] AV8 QPI I QPI0_DTX_DN[14] AD39 QPI O QPI1_DRX_DN[1] AW7 QPI I QPI0_DTX_DN[15] AC40 QPI O QPI1_DRX_DN[10] AR1 QPI I QPI0_DTX_DN[16] AC38 QPI O QPI1_DRX_DN[11] AR5 QPI I QPI0_DTX_DN[17] AB38 QPI O QPI1_DRX_DN[12] AN2 QPI I QPI0_DTX_DN[18] AE38 QPI O QPI1_DRX_DN[13] AM1 QPI I QPI0_DTX_DN[19] AF40 QPI O QPI1_DRX_DN[14] AM3 QPI I QPI0_DTX_DN[2] AK38 QPI O QPI1_DRX_DN[15] AP4 QPI I QPI0_DTX_DN[3] AJ39 QPI O QPI1_DRX_DN[16] AN4 QPI I QPI0_DTX_DN[4] AJ40 QPI O QPI1_DRX_DN[17] AN6 QPI I QPI0_DTX_DN[5] AK41 QPI O QPI1_DRX_DN[18] AM7 QPI I QPI0_DTX_DN[6] AH42 QPI O QPI1_DRX_DN[19] AL8 QPI I QPI0_DTX_DN[7] AJ42 QPI O QPI1_DRX_DN[2] BA8 QPI I QPI0_DTX_DN[8] AH43 QPI O QPI1_DRX_DN[3] AW5 QPI I QPI0_DTX_DN[9] AG41 QPI O QPI1_DRX_DN[4] BA6 QPI I QPI0_DTX_DP[0] AG38 QPI O QPI1_DRX_DN[5] AY5 QPI I QPI0_DTX_DP[1] AF39 QPI O QPI1_DRX_DN[6] AU6 QPI I QPI0_DTX_DP[10] AF43 QPI O QPI1_DRX_DN[7] AW3 QPI I QPI0_DTX_DP[11] AE42 QPI O QPI1_DRX_DN[8] AU3 QPI I QPI0_DTX_DP[12] AD42 QPI O QPI1_DRX_DN[9] AT2 QPI I QPI0_DTX_DP[13] AC43 QPI O QPI1_DRX_DP[0] AU8 QPI I QPI0_DTX_DP[14] AD40 QPI O QPI1_DRX_DP[1] AV7 QPI I QPI0_DTX_DP[15] AC41 QPI O QPI1_DRX_DP[10] AT1 QPI I QPI0_DTX_DP[16] AC39 QPI O QPI1_DRX_DP[11] AR4 QPI I QPI0_DTX_DP[17] AB39 QPI O QPI1_DRX_DP[12] AP2 QPI I QPI0_DTX_DP[18] AD38 QPI O QPI1_DRX_DP[13] AN1 QPI I QPI0_DTX_DP[19] AE40 QPI O QPI1_DRX_DP[14] AM2 QPI I QPI0_DTX_DP[2] AK37 QPI O QPI1_DRX_DP[15] AP3 QPI I QPI0_DTX_DP[3] AJ38 QPI O QPI1_DRX_DP[16] AM4 QPI I QPI0_DTX_DP[4] AH40 QPI O QPI1_DRX_DP[17] AN5 QPI I ® ® 50 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 5 of 36) (Sheet 6 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type QPI1_DRX_DP[18] AM6 QPI I QPI1_DTX_DP[18] AD5 QPI O QPI1_DRX_DP[19] AM8 QPI I QPI1_DTX_DP[19] AC8 QPI O QPI1_DRX_DP[2] AY8 QPI I QPI1_DTX_DP[2] AH6 QPI O QPI1_DRX_DP[3] AV5 QPI I QPI1_DTX_DP[3] AK6 QPI O QPI1_DRX_DP[4] BA7 QPI I QPI1_DTX_DP[4] AJ4 QPI O QPI1_DRX_DP[5] AY6 QPI I QPI1_DTX_DP[5] AG7 QPI O QPI1_DRX_DP[6] AU7 QPI I QPI1_DTX_DP[6] AJ3 QPI O QPI1_DRX_DP[7] AW4 QPI I QPI1_DTX_DP[7] AK1 QPI O QPI1_DRX_DP[8] AU4 QPI I QPI1_DTX_DP[8] AH3 QPI O QPI1_DRX_DP[9] AT3 QPI I QPI1_DTX_DP[9] AH2 QPI O QPI1_DTX_DN[0] AH8 QPI O DBR# AF10 Asynch I QPI1_DTX_DN[1] AJ7 QPI O DDR_COMP[0] AA8 Analog QPI1_DTX_DN[10] AF3 QPI O DDR_COMP[1] Y7 Analog QPI1_DTX_DN[11] AD1 QPI O DDR_COMP[2] AC1 Analog QPI1_DTX_DN[12] AD3 QPI O DDR_THERM# AB5 CMOS I QPI1_DTX_DN[13] AB3 QPI O DDR_VREF L23 Analog I QPI1_DTX_DN[14] AE4 QPI O DDR0_BA[0] B16 CMOS O QPI1_DTX_DN[15] AD4 QPI O DDR0_BA[1] A16 CMOS O QPI1_DTX_DN[16] AC6 QPI O DDR0_BA[2] C28 CMOS O QPI1_DTX_DN[17] AD7 QPI O DDR0_CAS# C12 CMOS O QPI1_DTX_DN[18] AE5 QPI O DDR0_CKE[0] C29 CMOS O QPI1_DTX_DN[19] AD8 QPI O DDR0_CKE[1] A30 CMOS O QPI1_DTX_DN[2] AJ6 QPI O DDR0_CKE[2] B30 CMOS O QPI1_DTX_DN[3] AK5 QPI O DDR0_CKE[3] B31 CMOS O QPI1_DTX_DN[4] AK4 QPI O DDR0_CLK_N[0] K19 CLOCK O QPI1_DTX_DN[5] AG6 QPI O DDR0_CLK_N[1] C19 CLOCK O QPI1_DTX_DN[6] AJ2 QPI O DDR0_CLK_N[2] E18 CLOCK O QPI1_DTX_DN[7] AJ1 QPI O DDR0_CLK_N[3] E19 CLOCK O QPI1_DTX_DN[8] AH4 QPI O DDR0_CLK_P[0] J19 CLOCK O QPI1_DTX_DN[9] AG2 QPI O DDR0_CLK_P[1] D19 CLOCK O QPI1_DTX_DP[0] AG8 QPI O DDR0_CLK_P[2] F18 CLOCK O QPI1_DTX_DP[1] AJ8 QPI O DDR0_CLK_P[3] E20 CLOCK O QPI1_DTX_DP[10] AF2 QPI O DDR0_CS#[0] G15 CMOS O QPI1_DTX_DP[11] AE1 QPI O DDR0_CS#[1] B10 CMOS O QPI1_DTX_DP[12] AD2 QPI O DDR0_CS#[2] C13 CMOS O QPI1_DTX_DP[13] AC3 QPI O DDR0_CS#[3] B9 CMOS O QPI1_DTX_DP[14] AE3 QPI O DDR0_CS#[4] B15 CMOS O QPI1_DTX_DP[15] AC4 QPI O DDR0_CS#[5] A7 CMOS O QPI1_DTX_DP[16] AB6 QPI O DDR0_CS#[6]/ C11 CMOS O DDR0_ODT[4] QPI1_DTX_DP[17] AD6 QPI O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 51 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 7 of 36) (Sheet 8 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type DDR0_CS#[7]/ B8 CMOS O DDR0_DQ[44] G1 CMOS I/O DDR0_ODT[5] DDR0_DQ[45] H3 CMOS I/O DDR0_DQ[0] W41 CMOS I/O DDR0_DQ[46] L3 CMOS I/O DDR0_DQ[1] V41 CMOS I/O DDR0_DQ[47] L2 CMOS I/O DDR0_DQ[10] K42 CMOS I/O DDR0_DQ[48] N1 CMOS I/O DDR0_DQ[11] K43 CMOS I/O DDR0_DQ[49] N2 CMOS I/O DDR0_DQ[12] P42 CMOS I/O DDR0_DQ[5] W42 CMOS I/O DDR0_DQ[13] P41 CMOS I/O DDR0_DQ[50] T1 CMOS I/O DDR0_DQ[14] L43 CMOS I/O DDR0_DQ[51] T2 CMOS I/O DDR0_DQ[15] L42 CMOS I/O DDR0_DQ[52] M3 CMOS I/O DDR0_DQ[16] H41 CMOS I/O DDR0_DQ[53] N3 CMOS I/O DDR0_DQ[17] H43 CMOS I/O DDR0_DQ[54] R4 CMOS I/O DDR0_DQ[18] E42 CMOS I/O DDR0_DQ[55] T3 CMOS I/O DDR0_DQ[19] E43 CMOS I/O DDR0_DQ[56] U4 CMOS I/O DDR0_DQ[2] R43 CMOS I/O DDR0_DQ[57] V1 CMOS I/O DDR0_DQ[20] J42 CMOS I/O DDR0_DQ[58] Y2 CMOS I/O DDR0_DQ[21] J41 CMOS I/O DDR0_DQ[59] Y3 CMOS I/O DDR0_DQ[22] F43 CMOS I/O DDR0_DQ[6] U41 CMOS I/O DDR0_DQ[23] F42 CMOS I/O DDR0_DQ[60] U1 CMOS I/O DDR0_DQ[24] D40 CMOS I/O DDR0_DQ[61] U3 CMOS I/O DDR0_DQ[25] C41 CMOS I/O DDR0_DQ[62] V4 CMOS I/O DDR0_DQ[26] A38 CMOS I/O DDR0_DQ[63] W4 CMOS I/O DDR0_DQ[27] D37 CMOS I/O DDR0_DQ[7] T42 CMOS I/O DDR0_DQ[28] D41 CMOS I/O DDR0_DQ[8] N41 CMOS I/O DDR0_DQ[29] D42 CMOS I/O DDR0_DQ[9] N43 CMOS I/O DDR0_DQ[3] R42 CMOS I/O DDR0_DQS_N[0] U43 CMOS I/O DDR0_DQ[30] C38 CMOS I/O DDR0_DQS_N[1] M41 CMOS I/O DDR0_DQ[31] B38 CMOS I/O DDR0_DQS_N[10] M43 CMOS I/O DDR0_DQ[32] B5 CMOS I/O DDR0_DQS_N[11] G43 CMOS I/O DDR0_DQ[33] C4 CMOS I/O DDR0_DQS_N[12] C39 CMOS I/O DDR0_DQ[34] F1 CMOS I/O DDR0_DQS_N[13] D4 CMOS I/O DDR0_DQ[35] G3 CMOS I/O DDR0_DQS_N[14] J1 CMOS I/O DDR0_DQ[36] B6 CMOS I/O DDR0_DQS_N[15] P1 CMOS I/O DDR0_DQ[37] C6 CMOS I/O DDR0_DQS_N[16] V3 CMOS I/O DDR0_DQ[38] F3 CMOS I/O DDR0_DQS_N[17] B35 CMOS I/O DDR0_DQ[39] F2 CMOS I/O DDR0_DQS_N[2] G41 CMOS I/O DDR0_DQ[4] W40 CMOS I/O DDR0_DQS_N[3] B40 CMOS I/O DDR0_DQ[40] H2 CMOS I/O DDR0_DQS_N[4] E4 CMOS I/O DDR0_DQ[41] H1 CMOS I/O DDR0_DQS_N[5] K3 CMOS I/O DDR0_DQ[42] L1 CMOS I/O DDR0_DQS_N[6] R3 CMOS I/O DDR0_DQ[43] M1 CMOS I/O ® ® 52 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 9 of 36) (Sheet 10 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type DDR0_DQS_N[7] W1 CMOS I/O DDR0_MA[5] B24 CMOS O DDR0_DQS_N[8] D35 CMOS I/O DDR0_MA[6] C24 CMOS O DDR0_DQS_N[9] V42 CMOS I/O DDR0_MA[7] A25 CMOS O DDR0_DQS_P[0] T43 CMOS I/O DDR0_MA[8] B25 CMOS O DDR0_DQS_P[1] L41 CMOS I/O DDR0_MA[9] C26 CMOS O DDR0_DQS_P[10] N42 CMOS I/O DDR0_MA_PAR B20 CMOS O DDR0_DQS_P[11] H42 CMOS I/O DDR0_ODT[0] F12 CMOS O DDR0_DQS_P[12] D39 CMOS I/O DDR0_ODT[1] C9 CMOS O DDR0_DQS_P[13] D5 CMOS I/O DDR0_ODT[2] B11 CMOS O DDR0_DQS_P[14] J2 CMOS I/O DDR0_ODT[3] C7 CMOS O DDR0_DQS_P[15] P2 CMOS I/O DDR0_PAR_ERR#[0] D25 Asynch I DDR0_DQS_P[16] V2 CMOS I/O DDR0_PAR_ERR#[1] B28 Asynch I DDR0_DQS_P[17] B36 CMOS I/O DDR0_PAR_ERR#[2] A27 Asynch I DDR0_DQS_P[2] F41 CMOS I/O DDR0_RAS# A15 CMOS O DDR0_DQS_P[3] B39 CMOS I/O DDR0_RESET# D32 CMOS O DDR0_DQS_P[4] E3 CMOS I/O DDR0_WE# B13 CMOS O DDR0_DQS_P[5] K2 CMOS I/O DDR1_BA[0] C18 CMOS O DDR0_DQS_P[6] R2 CMOS I/O DDR1_BA[1] K13 CMOS O DDR0_DQS_P[7] W2 CMOS I/O DDR1_BA[2] H27 CMOS O DDR0_DQS_P[8] D34 CMOS I/O DDR1_CAS# E14 CMOS O DDR0_DQS_P[9] V43 CMOS I/O DDR1_CKE[0] H28 CMOS O DDR0_ECC[0] C36 CMOS I/O DDR1_CKE[1] E27 CMOS O DDR0_ECC[1] A36 CMOS I/O DDR1_CKE[2] D27 CMOS O DDR0_ECC[2] F32 CMOS I/O DDR1_CKE[3] C27 CMOS O DDR0_ECC[3] C33 CMOS I/O DDR1_CLK_N[0] D21 CLOCK O DDR0_ECC[4] C37 CMOS I/O DDR1_CLK_N[1] G20 CLOCK O DDR0_ECC[5] A37 CMOS I/O DDR1_CLK_N[2] L18 CLOCK O DDR0_ECC[6] B34 CMOS I/O DDR1_CLK_N[3] H19 CLOCK O DDR0_ECC[7] C34 CMOS I/O DDR1_CLK_P[0] C21 CLOCK O DDR0_MA[0] A20 CMOS O DDR1_CLK_P[1] G19 CLOCK O DDR0_MA[1] B21 CMOS O DDR1_CLK_P[2] K18 CLOCK O DDR0_MA[10] B19 CMOS O DDR1_CLK_P[3] H18 CLOCK O DDR0_MA[11] A26 CMOS O DDR1_CS#[0] D12 CMOS O DDR0_MA[12] B26 CMOS O DDR1_CS#[1] A8 CMOS O DDR0_MA[13] A10 CMOS O DDR1_CS#[2] E15 CMOS O DDR0_MA[14] A28 CMOS O DDR1_CS#[3] E13 CMOS O DDR0_MA[15] B29 CMOS O DDR1_CS#[4] C17 CMOS O DDR0_MA[2] C23 CMOS O DDR1_CS#[5] E10 CMOS O DDR0_MA[3] D24 CMOS O DDR1_CS#[6]/ C14 CMOS O DDR1_ODT[4] DDR0_MA[4] B23 CMOS O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 53 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 11 of 36) (Sheet 12 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type DDR1_CS#[7]/ E12 CMOS O DDR1_DQ[44] G9 CMOS I/O DDR1_ODT[5] DDR1_DQ[45] H9 CMOS I/O DDR1_DQ[0] AA37 CMOS I/O DDR1_DQ[46] G5 CMOS I/O DDR1_DQ[1] AA36 CMOS I/O DDR1_DQ[47] J5 CMOS I/O DDR1_DQ[10] P39 CMOS I/O DDR1_DQ[48] K4 CMOS I/O DDR1_DQ[11] N39 CMOS I/O DDR1_DQ[49] K5 CMOS I/O DDR1_DQ[12] R34 CMOS I/O DDR1_DQ[5] AB36 CMOS I/O DDR1_DQ[13] R35 CMOS I/O DDR1_DQ[50] R5 CMOS I/O DDR1_DQ[14] N37 CMOS I/O DDR1_DQ[51] T5 CMOS I/O DDR1_DQ[15] N38 CMOS I/O DDR1_DQ[52] J4 CMOS I/O DDR1_DQ[16] M35 CMOS I/O DDR1_DQ[53] M6 CMOS I/O DDR1_DQ[17] M34 CMOS I/O DDR1_DQ[54] R8 CMOS I/O DDR1_DQ[18] K35 CMOS I/O DDR1_DQ[55] R7 CMOS I/O DDR1_DQ[19] J35 CMOS I/O DDR1_DQ[56] W6 CMOS I/O DDR1_DQ[2] Y35 CMOS I/O DDR1_DQ[57] W7 CMOS I/O DDR1_DQ[20] N34 CMOS I/O DDR1_DQ[58] Y10 CMOS I/O DDR1_DQ[21] M36 CMOS I/O DDR1_DQ[59] W10 CMOS I/O DDR1_DQ[22] J36 CMOS I/O DDR1_DQ[6] Y40 CMOS I/O DDR1_DQ[23] H36 CMOS I/O DDR1_DQ[60] V9 CMOS I/O DDR1_DQ[24] H33 CMOS I/O DDR1_DQ[61] W5 CMOS I/O DDR1_DQ[25] L33 CMOS I/O DDR1_DQ[62] AA7 CMOS I/O DDR1_DQ[26] K32 CMOS I/O DDR1_DQ[63] W9 CMOS I/O DDR1_DQ[27] J32 CMOS I/O DDR1_DQ[7] Y39 CMOS I/O DDR1_DQ[28] J34 CMOS I/O DDR1_DQ[8] P34 CMOS I/O DDR1_DQ[29] H34 CMOS I/O DDR1_DQ[9] P35 CMOS I/O DDR1_DQ[3] Y34 CMOS I/O DDR1_DQS_N[0] Y37 CMOS I/O DDR1_DQ[30] L32 CMOS I/O DDR1_DQS_N[1] R37 CMOS I/O DDR1_DQ[31] K30 CMOS I/O DDR1_DQS_N[10] P37 CMOS I/O DDR1_DQ[32] E9 CMOS I/O DDR1_DQS_N[11] K37 CMOS I/O DDR1_DQ[33] E8 CMOS I/O DDR1_DQS_N[12] K33 CMOS I/O DDR1_DQ[34] E5 CMOS I/O DDR1_DQS_N[13] F7 CMOS I/O DDR1_DQ[35] F5 CMOS I/O DDR1_DQS_N[14] J7 CMOS I/O DDR1_DQ[36] F10 CMOS I/O DDR1_DQS_N[15] M4 CMOS I/O DDR1_DQ[37] G8 CMOS I/O DDR1_DQS_N[16] Y5 CMOS I/O DDR1_DQ[38] D6 CMOS I/O DDR1_DQS_N[17] E35 CMOS I/O DDR1_DQ[39] F6 CMOS I/O DDR1_DQS_N[2] L36 CMOS I/O DDR1_DQ[4] AA35 CMOS I/O DDR1_DQS_N[3] L31 CMOS I/O DDR1_DQ[40] H8 CMOS I/O DDR1_DQS_N[4] D7 CMOS I/O DDR1_DQ[41] J6 CMOS I/O DDR1_DQS_N[5] G6 CMOS I/O DDR1_DQ[42] G4 CMOS I/O DDR1_DQS_N[6] L5 CMOS I/O DDR1_DQ[43] H4 CMOS I/O ® ® 54 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 13 of 36) (Sheet 14 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type DDR1_DQS_N[7] Y9 CMOS I/O DDR1_MA[5] F22 CMOS O DDR1_DQS_N[8] G34 CMOS I/O DDR1_MA[6] J27 CMOS O DDR1_DQS_N[9] AA41 CMOS I/O DDR1_MA[7] D22 CMOS O DDR1_DQS_P[0] Y38 CMOS I/O DDR1_MA[8] E22 CMOS O DDR1_DQS_P[1] R38 CMOS I/O DDR1_MA[9] G24 CMOS O DDR1_DQS_P[10] P36 CMOS I/O DDR1_MA_PAR D20 CMOS O DDR1_DQS_P[11] L37 CMOS I/O DDR1_ODT[0] D11 CMOS O DDR1_DQS_P[12] K34 CMOS I/O DDR1_ODT[1] C8 CMOS O DDR1_DQS_P[13] F8 CMOS I/O DDR1_ODT[2] D14 CMOS O DDR1_DQS_P[14] H7 CMOS I/O DDR1_ODT[3] F11 CMOS O DDR1_DQS_P[15] M5 CMOS I/O DDR1_PAR_ERR#[0] C22 Asynch I DDR1_DQS_P[16] Y4 CMOS I/O DDR1_PAR_ERR#[1] E25 Asynch I DDR1_DQS_P[17] F35 CMOS I/O DDR1_PAR_ERR#[2] F25 Asynch I DDR1_DQS_P[2] L35 CMOS I/O DDR1_RAS# G14 CMOS O DDR1_DQS_P[3] L30 CMOS I/O DDR1_RESET# D29 CMOS O DDR1_DQS_P[4] E7 CMOS I/O DDR1_WE# G13 CMOS O DDR1_DQS_P[5] H6 CMOS I/O DDR2_BA[0] A17 CMOS O DDR1_DQS_P[6] L6 CMOS I/O DDR2_BA[1] F17 CMOS O DDR1_DQS_P[7] Y8 CMOS I/O DDR2_BA[2] L26 CMOS O DDR1_DQS_P[8] G33 CMOS I/O DDR2_CAS# F16 CMOS O DDR1_DQS_P[9] AA40 CMOS I/O DDR2_CKE[0] J26 CMOS O DDR1_ECC[0] D36 CMOS I/O DDR2_CKE[1] G26 CMOS O DDR1_ECC[1] F36 CMOS I/O DDR2_CKE[2] D26 CMOS O DDR1_ECC[2] E33 CMOS I/O DDR2_CKE[3] L27 CMOS O DDR1_ECC[3] G36 CMOS I/O DDR2_CLK_N[0] J21 CLOCK O DDR1_ECC[4] E37 CMOS I/O DDR2_CLK_N[1] K20 CLOCK O DDR1_ECC[5] F37 CMOS I/O DDR2_CLK_N[2] G21 CLOCK O DDR1_ECC[6] E34 CMOS I/O DDR2_CLK_N[3] L21 CLOCK O DDR1_ECC[7] G35 CMOS I/O DDR2_CLK_P[0] J22 CLOCK O DDR1_MA[0] J14 CMOS O DDR2_CLK_P[1] L20 CLOCK O DDR1_MA[1] J16 CMOS O DDR2_CLK_P[2] H21 CLOCK O DDR1_MA[10] H14 CMOS O DDR2_CLK_P[3] L22 CLOCK O DDR1_MA[11] E23 CMOS O DDR2_CS#[0] G16 CMOS O DDR1_MA[12] E24 CMOS O DDR2_CS#[1] K14 CMOS O DDR1_MA[13] B14 CMOS O DDR2_CS#[2] D16 CMOS O DDR1_MA[14] H26 CMOS O DDR2_CS#[3] H16 CMOS O DDR1_MA[15] F26 CMOS O DDR2_CS#[4] E17 CMOS O DDR1_MA[2] J17 CMOS O DDR2_CS#[5] D9 CMOS O DDR1_MA[3] L28 CMOS O DDR2_CS#[6]/ L17 CMOS O DDR2_ODT[4] DDR1_MA[4] K28 CMOS O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 55 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 15 of 36) (Sheet 16 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type DDR2_CS#[7]/ J15 CMOS O DDR2_DQ[44] L11 CMOS I/O DDR2_ODT[5] DDR2_DQ[45] M10 CMOS I/O DDR2_DQ[0] W34 CMOS I/O DDR2_DQ[46] L8 CMOS I/O DDR2_DQ[1] W35 CMOS I/O DDR2_DQ[47] M8 CMOS I/O DDR2_DQ[10] R39 CMOS I/O DDR2_DQ[48] P7 CMOS I/O DDR2_DQ[11] T36 CMOS I/O DDR2_DQ[49] N6 CMOS I/O DDR2_DQ[12] W39 CMOS I/O DDR2_DQ[5] V34 CMOS I/O DDR2_DQ[13] V39 CMOS I/O DDR2_DQ[50] P9 CMOS I/O DDR2_DQ[14] T41 CMOS I/O DDR2_DQ[51] P10 CMOS I/O DDR2_DQ[15] R40 CMOS I/O DDR2_DQ[52] N8 CMOS I/O DDR2_DQ[16] M39 CMOS I/O DDR2_DQ[53] N7 CMOS I/O DDR2_DQ[17] M40 CMOS I/O DDR2_DQ[54] R10 CMOS I/O DDR2_DQ[18] J40 CMOS I/O DDR2_DQ[55] R9 CMOS I/O DDR2_DQ[19] J39 CMOS I/O DDR2_DQ[56] U5 CMOS I/O DDR2_DQ[2] V36 CMOS I/O DDR2_DQ[57] U6 CMOS I/O DDR2_DQ[20] P40 CMOS I/O DDR2_DQ[58] T10 CMOS I/O DDR2_DQ[21] N36 CMOS I/O DDR2_DQ[59] U10 CMOS I/O DDR2_DQ[22] L40 CMOS I/O DDR2_DQ[6] V37 CMOS I/O DDR2_DQ[23] K38 CMOS I/O DDR2_DQ[60] T6 CMOS I/O DDR2_DQ[24] G40 CMOS I/O DDR2_DQ[61] T7 CMOS I/O DDR2_DQ[25] F40 CMOS I/O DDR2_DQ[62] V8 CMOS I/O DDR2_DQ[26] J37 CMOS I/O DDR2_DQ[63] U9 CMOS I/O DDR2_DQ[27] H37 CMOS I/O DDR2_DQ[7] V38 CMOS I/O DDR2_DQ[28] H39 CMOS I/O DDR2_DQ[8] U38 CMOS I/O DDR2_DQ[29] G39 CMOS I/O DDR2_DQ[9] U39 CMOS I/O DDR2_DQ[3] U36 CMOS I/O DDR2_DQS_N[0] W36 CMOS I/O DDR2_DQ[30] F38 CMOS I/O DDR2_DQS_N[1] T38 CMOS I/O DDR2_DQ[31] E38 CMOS I/O DDR2_DQS_N[10] T40 CMOS I/O DDR2_DQ[32] K12 CMOS I/O DDR2_DQS_N[11] L38 CMOS I/O DDR2_DQ[33] J12 CMOS I/O DDR2_DQS_N[12] G38 CMOS I/O DDR2_DQ[34] H13 CMOS I/O DDR2_DQS_N[13] J11 CMOS I/O DDR2_DQ[35] L13 CMOS I/O DDR2_DQS_N[14] K8 CMOS I/O DDR2_DQ[36] G11 CMOS I/O DDR2_DQS_N[15] P4 CMOS I/O DDR2_DQ[37] G10 CMOS I/O DDR2_DQS_N[16] V7 CMOS I/O DDR2_DQ[38] H12 CMOS I/O DDR2_DQS_N[17] G31 CMOS I/O DDR2_DQ[39] L12 CMOS I/O DDR2_DQS_N[2] K39 CMOS I/O DDR2_DQ[4] U34 CMOS I/O DDR2_DQS_N[3] E40 CMOS I/O DDR2_DQ[40] L10 CMOS I/O DDR2_DQS_N[4] J9 CMOS I/O DDR2_DQ[41] K10 CMOS I/O DDR2_DQS_N[5] K7 CMOS I/O DDR2_DQ[42] M9 CMOS I/O DDR2_DQS_N[6] P5 CMOS I/O DDR2_DQ[43] N9 CMOS I/O ® ® 56 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 17 of 36) (Sheet 18 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type DDR2_DQS_N[7] T8 CMOS I/O DDR2_MA[5] K23 CMOS O DDR2_DQS_N[8] G30 CMOS I/O DDR2_MA[6] K22 CMOS O DDR2_DQS_N[9] T35 CMOS I/O DDR2_MA[7] J24 CMOS O DDR2_DQS_P[0] W37 CMOS I/O DDR2_MA[8] L25 CMOS O DDR2_DQS_P[1] T37 CMOS I/O DDR2_MA[9] H22 CMOS O DDR2_DQS_P[10] U40 CMOS I/O DDR2_MA_PAR B18 CMOS O DDR2_DQS_P[11] M38 CMOS I/O DDR2_ODT[0] L16 CMOS O DDR2_DQS_P[12] H38 CMOS I/O DDR2_ODT[1] F13 CMOS O DDR2_DQS_P[13] H11 CMOS I/O DDR2_ODT[2] D15 CMOS O DDR2_DQS_P[14] K9 CMOS I/O DDR2_ODT[3] D10 CMOS O DDR2_DQS_P[15] N4 CMOS I/O DDR2_PAR_ERR#[0] F21 Asynch I DDR2_DQS_P[16] V6 CMOS I/O DDR2_PAR_ERR#[1] J25 Asynch I DDR2_DQS_P[17] H31 CMOS I/O DDR2_PAR_ERR#[2] F23 Asynch I DDR2_DQS_P[2] K40 CMOS I/O DDR2_RAS# D17 CMOS O DDR2_DQS_P[3] E39 CMOS I/O DDR2_RESET# E32 CMOS O DDR2_DQS_P[4] J10 CMOS I/O DDR2_WE# C16 CMOS O DDR2_DQS_P[5] L7 CMOS I/O FC_AH5 AH5 DDR2_DQS_P[6] P6 CMOS I/O GTLREF AJ37 Analog I DDR2_DQS_P[7] U8 CMOS I/O ISENSE AK8 Analog I DDR2_DQS_P[8] G29 CMOS I/O PECI AH36 Asynch I/O DDR2_DQS_P[9] U35 CMOS I/O PECI_ID# AK35 Asynch I DDR2_ECC[0] H32 CMOS I/O PRDY# B41 GTL O DDR2_ECC[1] F33 CMOS I/O PREQ# C42 GTL I DDR2_ECC[2] E29 CMOS I/O PROCHOT# AG35 GTL I/O DDR2_ECC[3] E30 CMOS I/O PSI# AP7 CMOS O DDR2_ECC[4] J31 CMOS I/O RESET# AL39 Asynch I DDR2_ECC[5] J30 CMOS I/O RSVD A31 DDR2_ECC[6] F31 CMOS I/O RSVD A40 DDR2_ECC[7] F30 CMOS I/O RSVD AF1 DDR2_MA[0] A18 CMOS O RSVD AF4 DDR2_MA[1] K17 CMOS O RSVD AG1 DDR2_MA[10] H17 CMOS O RSVD AG4 DDR2_MA[11] H23 CMOS O RSVD AG5 DDR2_MA[12] G23 CMOS O RSVD AK2 DDR2_MA[13] F15 CMOS O RSVD AK7 DDR2_MA[14] H24 CMOS O RSVD AK36 DDR2_MA[15] G25 CMOS O RSVD AL3 DDR2_MA[2] G18 CMOS O RSVD AL38 DDR2_MA[3] J20 CMOS O RSVD AL4 DDR2_MA[4] F20 CMOS O RSVD AL40 ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 57 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 19 of 36) (Sheet 20 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type RSVD AL41 RSVD K15 RSVD AL5 RSVD K24 RSVD AM36 RSVD K25 RSVD AM38 RSVD K27 RSVD AN36 RSVD K29 RSVD AN38 RSVD L15 RSVD AR36 RSVD U11 RSVD AR37 RSVD V11 RSVD AT36 SKTOCC# AG36 GTL O RSVD AT4 TCK AH10 TAP I RSVD AT5 TDI AJ9 TAP I RSVD AU2 TDO AJ10 TAP O RSVD AV1 THERMTRIP# AG37 GTL O RSVD AV2 TMS AG10 TAP I RSVD AV35 TRST# AH9 TAP I RSVD AV42 VCC AH11 PWR RSVD AV43 VCC AH33 PWR RSVD AW2 VCC AJ11 PWR RSVD AW39 VCC AJ33 PWR RSVD AW41 VCC AK11 PWR RSVD AW42 VCC AK12 PWR RSVD AY3 VCC AK13 PWR RSVD AY35 VCC AK15 PWR RSVD AY39 VCC AK16 PWR RSVD AY4 VCC AK18 PWR RSVD AY40 VCC AK19 PWR RSVD AY41 VCC AK21 PWR RSVD B33 VCC AK24 PWR RSVD BA4 VCC AK25 PWR RSVD BA40 VCC AK27 PWR RSVD C31 VCC AK28 PWR RSVD C32 VCC AK30 PWR RSVD D30 VCC AK31 PWR RSVD D31 VCC AK33 PWR RSVD E28 VCC AL12 PWR RSVD F27 VCC AL13 PWR RSVD F28 VCC AL15 PWR RSVD G28 VCC AL16 PWR RSVD H29 VCC AL18 PWR RSVD J29 VCC AL19 PWR ® ® 58 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 21 of 36) (Sheet 22 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VCC AL21 PWR VCC AP13 PWR VCC AL24 PWR VCC AP15 PWR VCC AL25 PWR VCC AP16 PWR VCC AL27 PWR VCC AP18 PWR VCC AL28 PWR VCC AP19 PWR VCC AL30 PWR VCC AP21 PWR VCC AL31 PWR VCC AP24 PWR VCC AL33 PWR VCC AP25 PWR VCC AL34 PWR VCC AP27 PWR VCC AM12 PWR VCC AP28 PWR VCC AM13 PWR VCC AP30 PWR VCC AM15 PWR VCC AP31 PWR VCC AM16 PWR VCC AP33 PWR VCC AM18 PWR VCC AP34 PWR VCC AM19 PWR VCC AR10 PWR VCC AM21 PWR VCC AR12 PWR VCC AM24 PWR VCC AR13 PWR VCC AM25 PWR VCC AR15 PWR VCC AM27 PWR VCC AR16 PWR VCC AM28 PWR VCC AR18 PWR VCC AM30 PWR VCC AR19 PWR VCC AM31 PWR VCC AR21 PWR VCC AM33 PWR VCC AR24 PWR VCC AM34 PWR VCC AR25 PWR VCC AN12 PWR VCC AR27 PWR VCC AN13 PWR VCC AR28 PWR VCC AN15 PWR VCC AR30 PWR VCC AN16 PWR VCC AR31 PWR VCC AN18 PWR VCC AR33 PWR VCC AN19 PWR VCC AR34 PWR VCC AN21 PWR VCC AT10 PWR VCC AN24 PWR VCC AT12 PWR VCC AN25 PWR VCC AT13 PWR VCC AN27 PWR VCC AT15 PWR VCC AN28 PWR VCC AT16 PWR VCC AN30 PWR VCC AT18 PWR VCC AN31 PWR VCC AT19 PWR VCC AN33 PWR VCC AT21 PWR VCC AN34 PWR VCC AT24 PWR VCC AP12 PWR VCC AT25 PWR ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 59 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 23 of 36) (Sheet 24 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VCC AT27 PWR VCC AV9 PWR VCC AT28 PWR VCC AW10 PWR VCC AT30 PWR VCC AW12 PWR VCC AT31 PWR VCC AW13 PWR VCC AT33 PWR VCC AW15 PWR VCC AT34 PWR VCC AW16 PWR VCC AT9 PWR VCC AW18 PWR VCC AU10 PWR VCC AW19 PWR VCC AU12 PWR VCC AW21 PWR VCC AU13 PWR VCC AW24 PWR VCC AU15 PWR VCC AW25 PWR VCC AU16 PWR VCC AW27 PWR VCC AU18 PWR VCC AW28 PWR VCC AU19 PWR VCC AW30 PWR VCC AU21 PWR VCC AW31 PWR VCC AU24 PWR VCC AW33 PWR VCC AU25 PWR VCC AW34 PWR VCC AU27 PWR VCC AW9 PWR VCC AU28 PWR VCC AY10 PWR VCC AU30 PWR VCC AY12 PWR VCC AU31 PWR VCC AY13 PWR VCC AU33 PWR VCC AY15 PWR VCC AU34 PWR VCC AY16 PWR VCC AU9 PWR VCC AY18 PWR VCC AV10 PWR VCC AY19 PWR VCC AV12 PWR VCC AY21 PWR VCC AV13 PWR VCC AY24 PWR VCC AV15 PWR VCC AY25 PWR VCC AV16 PWR VCC AY27 PWR VCC AV18 PWR VCC AY28 PWR VCC AV19 PWR VCC AY30 PWR VCC AV21 PWR VCC AY31 PWR VCC AV24 PWR VCC AY33 PWR VCC AV25 PWR VCC AY34 PWR VCC AV27 PWR VCC AY9 PWR VCC AV28 PWR VCC BA10 PWR VCC AV30 PWR VCC BA12 PWR VCC AV31 PWR VCC BA13 PWR VCC AV33 PWR VCC BA15 PWR VCC AV34 PWR VCC BA16 PWR ® ® 60 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 25 of 36) (Sheet 26 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VCC BA18 PWR VDDQ B32 PWR VCC BA19 PWR VDDQ B7 PWR VCC BA24 PWR VDDQ C10 PWR VCC BA25 PWR VDDQ C15 PWR VCC BA27 PWR VDDQ C20 PWR VCC BA28 PWR VDDQ C25 PWR VCC BA30 PWR VDDQ C30 PWR VCC BA9 PWR VDDQ D13 PWR VCC M11 PWR VDDQ D18 PWR VCC M13 PWR VDDQ D23 PWR VCC M15 PWR VDDQ D28 PWR VCC M19 PWR VDDQ E11 PWR VCC M21 PWR VDDQ E16 PWR VCC M23 PWR VDDQ E21 PWR VCC M25 PWR VDDQ E26 PWR VCC M29 PWR VDDQ E31 PWR VCC M31 PWR VDDQ F14 PWR VCC M33 PWR VDDQ F19 PWR VCC N11 PWR VDDQ F24 PWR VCC N33 PWR VDDQ G17 PWR VCC R11 PWR VDDQ G22 PWR VCC R33 PWR VDDQ G27 PWR VCC T11 PWR VDDQ H15 PWR VCC T33 PWR VDDQ H20 PWR VCC W11 PWR VDDQ H25 PWR VCC_SENSE AR9 Analog VDDQ J18 PWR VCCPLL U33 PWR VDDQ J23 PWR VCCPLL V33 PWR VDDQ J28 PWR VCCPLL W33 PWR VDDQ K16 PWR VCCPWRGOOD AR7 Asynch I VDDQ K21 PWR VDDPWRGOOD AA6 Asynch I VDDQ K26 PWR VDDQ A14 PWR VDDQ L14 PWR VDDQ A19 PWR VDDQ L19 PWR VDDQ A24 PWR VDDQ L24 PWR VDDQ A29 PWR VDDQ M17 PWR VDDQ A9 PWR VDDQ M27 PWR VDDQ B12 PWR VID[0]/MSID[0] AL10 CMOS O VDDQ B17 PWR VID[1]/MSID[1] AL9 CMOS O VDDQ B22 PWR VID[2]/MSID[2] AN9 CMOS O VDDQ B27 PWR VID[3]/CSC[0] AM10 CMOS O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 61 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 27 of 36) (Sheet 28 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VID[4]/CSC[1] AN10 CMOS O VSS AG9 GND VID[5]/CSC[2] AP9 CSMO O VSS AH1 GND VID[6] AP8 CMOS O VSS AH34 GND VID[7] AN8 CMOS O VSS AH37 GND VSS A35 GND VSS AH39 GND VSS A39 GND VSS AH7 GND VSS A4 GND VSS AJ34 GND VSS A41 GND VSS AJ36 GND VSS A6 GND VSS AJ41 GND VSS AA3 GND VSS AJ5 GND VSS AA34 GND VSS AK10 GND VSS AA38 GND VSS AK14 GND VSS AA39 GND VSS AK17 GND VSS AA9 GND VSS AK20 GND VSS AB37 GND VSS AK22 GND VSS AB4 GND VSS AK23 GND VSS AB40 GND VSS AK26 GND VSS AB42 GND VSS AK29 GND VSS AB7 GND VSS AK3 GND VSS AC2 GND VSS AK32 GND VSS AC36 GND VSS AK34 GND VSS AC5 GND VSS AK39 GND VSS AC7 GND VSS AK43 GND VSS AC9 GND VSS AK9 GND VSS AD11 GND VSS AL1 GND VSS AD33 GND VSS AL11 GND VSS AD37 GND VSS AL14 GND VSS AD41 GND VSS AL17 GND VSS AD43 GND VSS AL2 GND VSS AE2 GND VSS AL20 GND VSS AE39 GND VSS AL22 GND VSS AE7 GND VSS AL23 GND VSS AF35 GND VSS AL26 GND VSS AF38 GND VSS AL29 GND VSS AF41 GND VSS AL32 GND VSS AF5 GND VSS AL35 GND VSS AG11 GND VSS AL36 GND VSS AG3 GND VSS AL37 GND VSS AG33 GND VSS AL42 GND VSS AG43 GND VSS AL7 GND ® ® 62 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 29 of 36) (Sheet 30 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VSS AM11 GND VSS AP36 GND VSS AM14 GND VSS AP37 GND VSS AM17 GND VSS AP43 GND VSS AM20 GND VSS AP5 GND VSS AM22 GND VSS AP6 GND VSS AM23 GND VSS AR11 GND VSS AM26 GND VSS AR14 GND VSS AM29 GND VSS AR17 GND VSS AM32 GND VSS AR2 GND VSS AM35 GND VSS AR20 GND VSS AM37 GND VSS AR22 GND VSS AM39 GND VSS AR23 GND VSS AM5 GND VSS AR26 GND VSS AM9 GND VSS AR29 GND VSS AN11 GND VSS AR3 GND VSS AN14 GND VSS AR32 GND VSS AN17 GND VSS AR35 GND VSS AN20 GND VSS AR39 GND VSS AN22 GND VSS AT11 GND VSS AN23 GND VSS AT14 GND VSS AN26 GND VSS AT17 GND VSS AN29 GND VSS AT20 GND VSS AN3 GND VSS AT22 GND VSS AN32 GND VSS AT23 GND VSS AN35 GND VSS AT26 GND VSS AN37 GND VSS AT29 GND VSS AN41 GND VSS AT32 GND VSS AN7 GND VSS AT35 GND VSS AP1 GND VSS AT38 GND VSS AP10 GND VSS AT41 GND VSS AP11 GND VSS AT7 GND VSS AP14 GND VSS AT8 GND VSS AP17 GND VSS AU1 GND VSS AP20 GND VSS AU11 GND VSS AP22 GND VSS AU14 GND VSS AP23 GND VSS AU17 GND VSS AP26 GND VSS AU20 GND VSS AP29 GND VSS AU22 GND VSS AP32 GND VSS AU23 GND VSS AP35 GND VSS AU26 GND ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 63 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 31 of 36) (Sheet 32 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VSS AU29 GND VSS AY32 GND VSS AU32 GND VSS AY37 GND VSS AU35 GND VSS AY42 GND VSS AU36 GND VSS AY7 GND VSS AU43 GND VSS B2 GND VSS AU5 GND VSS B37 GND VSS AV11 GND VSS B42 GND VSS AV14 GND VSS BA11 GND VSS AV17 GND VSS BA14 GND VSS AV20 GND VSS BA17 GND VSS AV22 GND VSS BA20 GND VSS AV23 GND VSS BA26 GND VSS AV26 GND VSS BA29 GND VSS AV29 GND VSS BA3 GND VSS AV32 GND VSS BA35 GND VSS AV39 GND VSS BA39 GND VSS AV4 GND VSS BA5 GND VSS AV41 GND VSS C35 GND VSS AW1 GND VSS C40 GND VSS AW11 GND VSS C43 GND VSS AW14 GND VSS C5 GND VSS AW17 GND VSS D3 GND VSS AW20 GND VSS D33 GND VSS AW22 GND VSS D38 GND VSS AW23 GND VSS D43 GND VSS AW26 GND VSS D8 GND VSS AW29 GND VSS E1 GND VSS AW32 GND VSS E36 GND VSS AW35 GND VSS E41 GND VSS AW6 GND VSS E6 GND VSS AW8 GND VSS F29 GND VSS AY11 GND VSS F34 GND VSS AY14 GND VSS F39 GND VSS AY17 GND VSS F4 GND VSS AY2 GND VSS F9 GND VSS AY20 GND VSS G12 GND VSS AY22 GND VSS G2 GND VSS AY23 GND VSS G32 GND VSS AY26 GND VSS G37 GND VSS AY29 GND VSS G42 GND ® ® 64 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 33 of 36) (Sheet 34 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VSS G7 GND VSS N40 GND VSS H10 GND VSS N5 GND VSS H30 GND VSS P11 GND VSS H35 GND VSS P3 GND VSS H40 GND VSS P33 GND VSS H5 GND VSS P38 GND VSS J13 GND VSS P43 GND VSS J3 GND VSS P8 GND VSS J33 GND VSS R1 GND VSS J38 GND VSS R36 GND VSS J43 GND VSS R41 GND VSS J8 GND VSS R6 GND VSS K1 GND VSS T34 GND VSS K11 GND VSS T39 GND VSS K31 GND VSS T4 GND VSS K36 GND VSS T9 GND VSS K41 GND VSS U2 GND VSS K6 GND VSS U37 GND VSS L29 GND VSS U42 GND VSS L34 GND VSS U7 GND VSS L39 GND VSS V10 GND VSS L4 GND VSS V35 GND VSS L9 GND VSS V40 GND VSS M12 GND VSS V5 GND VSS M14 GND VSS W3 GND VSS M16 GND VSS W38 GND VSS M18 GND VSS W43 GND VSS M2 GND VSS W8 GND VSS M20 GND VSS Y1 GND VSS M22 GND VSS Y11 GND VSS M24 GND VSS Y33 GND VSS M26 GND VSS Y36 GND VSS M28 GND VSS Y41 GND VSS M30 GND VSS Y6 GND VSS M32 GND VSS_SENSE AR8 Analog VSS M37 GND VSS_SENSE_VTTD AE37 Analog VSS M42 GND VTT_VID2 AV3 CMOS O VSS M7 GND VTT_VID3 AF7 CMOS O VSS N10 GND VTT_VID4 AV6 CMOS O VSS N35 GND VTTA AD10 PWR ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 65 Land Listing Table 4-1. Land Listing by Land Name Table 4-1. Land Listing by Land Name (Sheet 35 of 36) (Sheet 36 of 36) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type VTTA AE10 PWR VTTD AC11 PWR VTTA AE11 PWR VTTD AC33 PWR VTTA AE33 PWR VTTD AC34 PWR VTTA AF11 PWR VTTD AC35 PWR VTTA AF33 PWR VTTD AD34 PWR VTTA AF34 PWR VTTD AD35 PWR VTTA AG34 PWR VTTD AD36 PWR VTTD AA10 PWR VTTD AD9 PWR VTTD AA11 PWR VTTD AE34 PWR VTTD AA33 PWR VTTD AE35 PWR VTTD AB10 PWR VTTD AE8 PWR VTTD AB11 PWR VTTD AE9 PWR VTTD AB33 PWR VTTD AF36 PWR VTTD AB34 PWR VTTD AF37 PWR VTTD AB8 PWR VTTD AF8 PWR VTTD AB9 PWR VTTD AF9 PWR VTTD AC10 PWR VTTD_SENSE AE36 Analog VTTPWRGOOD AB35 Asynch I ® ® 66 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing 4.1.2 Land Listing by Land Number Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 2 of 35) (Sheet 1 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AA34 VSS GND A4 VSS GND AA35 DDR1_DQ[4] CMOS I/O A5 BPM#[1] GTL I/O AA36 DDR1_DQ[1] CMOS I/O A6 VSS GND AA37 DDR1_DQ[0] CMOS I/O A7 DDR0_CS#[5] CMOS O AA38 VSS GND A8 DDR1_CS#[1] CMOS O AA39 VSS GND A9 VDDQ PWR AA40 DDR1_DQS_P[9] CMOS I/O A10 DDR0_MA[13] CMOS O AA41 DDR1_DQS_N[9] CMOS I/O A14 VDDQ PWR AB3 QPI1_DTX_DN[13] QPI O A15 DDR0_RAS# CMOS O AB4 VSS GND A16 DDR0_BA[1] CMOS O AB5 DDR_THERM# CMOS I A17 DDR2_BA[0] CMOS O AB6 QPI1_DTX_DP[16] QPI O A18 DDR2_MA[0] CMOS O AB7 VSS GND A19 VDDQ PWR AB8 VTTD PWR A20 DDR0_MA[0] CMOS O AB9 VTTD PWR A24 VDDQ PWR AB10 VTTD PWR A25 DDR0_MA[7] CMOS O AB11 VTTD PWR A26 DDR0_MA[11] CMOS O AB33 VTTD PWR A27 DDR0_PAR_ERR#[2] Asynch I AB34 VTTD PWR A28 DDR0_MA[14] CMOS O AB35 VTTPWRGOOD Asynch I A29 VDDQ PWR AB36 DDR1_DQ[5] CMOS I/O A30 DDR0_CKE[1] CMOS O AB37 VSS GND A31 RSVD AB38 QPI0_DTX_DN[17] QPI O A35 VSS GND AB39 QPI0_DTX_DP[17] QPI O A36 DDR0_ECC[1] CMOS I/O AB40 VSS GND A37 DDR0_ECC[5] CMOS I/O AB41 COMP0 Analog A38 DDR0_DQ[26] CMOS I/O AB42 VSS GND A39 VSS GND AB43 QPI0_DTX_DN[13] QPI O A40 RSVD AC1 DDR_COMP[2] Analog A41 VSS GND AC2 VSS GND AA3 VSS GND AC3 QPI1_DTX_DP[13] QPI O AA4 BCLK_ITP_DN CMOS O AC4 QPI1_DTX_DP[15] QPI O AA5 BCLK_ITP_DP CMOS O AC5 VSS GND AA6 VDDPWRGOOD Asynch I AC6 QPI1_DTX_DN[16] QPI O AA7 DDR1_DQ[62] CMOS I/O AC7 VSS GND AA8 DDR_COMP[0] Analog AC8 QPI1_DTX_DP[19] QPI O AA9 VSS GND AC9 VSS GND AA10 VTTD PWR AC10 VTTD PWR AA11 VTTD PWR AC11 VTTD PWR AA33 VTTD PWR ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 67 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 3 of 35) (Sheet 4 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AC33 VTTD PWR AE8 VTTD PWR AC34 VTTD PWR AE9 VTTD PWR AC35 VTTD PWR AE10 VTTA PWR AC36 VSS GND AE11 VTTA PWR AC37 CAT_ERR# GTL I/O AE33 VTTA PWR AC38 QPI0_DTX_DN[16] QPI O AE34 VTTD PWR AC39 QPI0_DTX_DP[16] QPI O AE35 VTTD PWR AC40 QPI0_DTX_DN[15] QPI O AE36 VTTD_SENSE Analog AC41 QPI0_DTX_DP[15] QPI O AE37 VSS_SENSE_VTTD Analog AC42 QPI0_DTX_DN[12] QPI O AE38 QPI0_DTX_DN[18] QPI O AC43 QPI0_DTX_DP[13] QPI O AE39 VSS GND AD1 QPI1_DTX_DN[11] QPI O AE40 QPI0_DTX_DP[19] QPI O AD2 QPI1_DTX_DP[12] QPI O AE41 QPI0_DTX_DN[11] QPI O AD3 QPI1_DTX_DN[12] QPI O AE42 QPI0_DTX_DP[11] QPI O AD4 QPI1_DTX_DN[15] QPI O AE43 QPI0_DTX_DN[10] QPI O AD5 QPI1_DTX_DP[18] QPI O AF1 RSVD AD6 QPI1_DTX_DP[17] QPI O AF2 QPI1_DTX_DP[10] QPI O AD7 QPI1_DTX_DN[17] QPI O AF3 QPI1_DTX_DN[10] QPI O AD8 QPI1_DTX_DN[19] QPI O AF4 RSVD AD9 VTTD PWR AF5 VSS GND AD10 VTTA PWR AF6 QPI1_CLKTX_DP QPI O AD11 VSS GND AF7 VTT_VID3 CMOS O AD33 VSS GND AF8 VTTD PWR AD34 VTTD PWR AF9 VTTD PWR AD35 VTTD PWR AF10 DBR# Asynch I AD36 VTTD PWR AF11 VTTA PWR AD37 VSS GND AF33 VTTA PWR AD38 QPI0_DTX_DP[18] QPI O AF34 VTTA PWR AD39 QPI0_DTX_DN[14] QPI O AF35 VSS GND AD40 QPI0_DTX_DP[14] QPI O AF36 VTTD PWR AD41 VSS GND AF37 VTTD AD42 QPI0_DTX_DP[12] QPI O AF38 VSS GND AD43 VSS GND AF39 QPI0_DTX_DP[1] QPI O AE1 QPI1_DTX_DP[11] QPI O AF40 QPI0_DTX_DN[19] QPI O AE2 VSS GND AF41 VSS GND AE3 QPI1_DTX_DP[14] QPI O AF42 QPI0_CLKTX_DN QPI O AE4 QPI1_DTX_DN[14] QPI O AF43 QPI0_DTX_DP[10] QPI O AE5 QPI1_DTX_DN[18] QPI O AG1 RSVD AE6 QPI1_CLKTX_DN QPI O AG2 QPI1_DTX_DN[9] QPI O AE7 VSS GND AG3 VSS GND ® ® 68 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 5 of 35) (Sheet 6 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AG4 RSVD AH43 QPI0_DTX_DN[8] QPI O AG5 RSVD AJ1 QPI1_DTX_DN[7] QPI O AG6 QPI1_DTX_DN[5] QPI O AJ2 QPI1_DTX_DN[6] QPI O AG7 QPI1_DTX_DP[5] QPI O AJ3 QPI1_DTX_DP[6] QPI O AG8 QPI1_DTX_DP[0] QPI O AJ4 QPI1_DTX_DP[4] QPI O AG9 VSS GND AJ5 VSS GND AG10 TMS TAP I AJ6 QPI1_DTX_DN[2] QPI O AG11 VSS GND AJ7 QPI1_DTX_DN[1] QPI O AG33 VSS GND AJ8 QPI1_DTX_DP[1] QPI O AG34 VTTA PWR AJ9 TDI TAP I AG35 PROCHOT# GTL I/O AJ10 TDO TAP O AG36 SKTOCC# GTL O AJ11 VCC PWR AG37 THERMTRIP# GTL O AJ33 VCC PWR AG38 QPI0_DTX_DP[0] QPI O AJ34 VSS GND AG39 QPI0_DTX_DN[1] QPI O AJ35 BCLK_DP CMOS I AG40 QPI0_DTX_DP[9] QPI O AJ36 VSS GND AG41 QPI0_DTX_DN[9] QPI O AJ37 GTLREF Analog I AG42 QPI0_CLKTX_DP QPI O AJ38 QPI0_DTX_DP[3] QPI O AG43 VSS GND AJ39 QPI0_DTX_DN[3] QPI O AH1 VSS GND AJ40 QPI0_DTX_DN[4] QPI O AH2 QPI1_DTX_DP[9] QPI O AJ41 VSS GND AH3 QPI1_DTX_DP[8] QPI O AJ42 QPI0_DTX_DN[7] QPI O AH4 QPI1_DTX_DN[8] QPI O AJ43 QPI0_DTX_DP[8] QPI O AH5 FC_AH5 AK1 QPI1_DTX_DP[7] QPI O AH6 QPI1_DTX_DP[2] QPI O AK2 RSVD AH7 VSS GND AK3 VSS GND AH8 QPI1_DTX_DN[0] QPI O AK4 QPI1_DTX_DN[4] QPI O AH9 TRST# TAP I AK5 QPI1_DTX_DN[3] QPI O AH10 TCK TAP I AK6 QPI1_DTX_DP[3] QPI O AH11 VCC PWR AK7 RSVD AH33 VCC PWR AK8 ISENSE Analog I AH34 VSS GND AK9 VSS GND AH35 BCLK_DN CMOS I AK10 VSS GND AH36 PECI Asynch I/O AK11 VCC PWR AH37 VSS GND AK12 VCC PWR AH38 QPI0_DTX_DN[0] QPI O AK13 VCC PWR AH39 VSS GND AK14 VSS GND AH40 QPI0_DTX_DP[4] QPI O AK15 VCC PWR AH41 QPI0_DTX_DP[6] QPI O AK16 VCC PWR AH42 QPI0_DTX_DN[6] QPI O AK17 VSS GND ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 69 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 7 of 35) (Sheet 8 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AK18 VCC PWR AL15 VCC PWR AK19 VCC PWR AL16 VCC PWR AK20 VSS GND AL17 VSS GND AK21 VCC PWR AL18 VCC PWR AK22 VSS GND AL19 VCC PWR AK23 VSS GND AL20 VSS GND AK24 VCC PWR AL21 VCC PWR AK25 VCC PWR AL22 VSS GND AK26 VSS GND AL23 VSS GND AK27 VCC PWR AL24 VCC PWR AK28 VCC PWR AL25 VCC PWR AK29 VSS GND AL26 VSS GND AK30 VCC PWR AL27 VCC PWR AK31 VCC PWR AL28 VCC PWR AK32 VSS GND AL29 VSS GND AK33 VCC PWR AL30 VCC PWR AK34 VSS GND AL31 VCC PWR AK35 PECI_ID# Asynch I AL32 VSS GND AK36 RSVD AL33 VCC PWR AK37 QPI0_DTX_DP[2] QPI O AL34 VCC PWR AK38 QPI0_DTX_DN[2] QPI O AL35 VSS GND AK39 VSS GND AL36 VSS GND AK40 QPI0_DTX_DP[5] QPI O AL37 VSS GND AK41 QPI0_DTX_DN[5] QPI O AL38 RSVD AK42 QPI0_DTX_DP[7] QPI O AL39 RESET# Asynch I AK43 VSS GND AL40 RSVD AL1 VSS GND AL41 RSVD AL2 VSS GND AL42 VSS GND AL3 RSVD AL43 QPI0_COMP Analog AL4 RSVD AM1 QPI1_DRX_DN[13] QPI I AL5 RSVD AM2 QPI1_DRX_DP[14] QPI I AL6 QPI1_COMP Analog AM3 QPI1_DRX_DN[14] QPI I AL7 VSS GND AM4 QPI1_DRX_DP[16] QPI I AL8 QPI1_DRX_DN[19] QPI I AM5 VSS GND AL9 VID[1]/MSID[1] CMOS O AM6 QPI1_DRX_DP[18] QPI I AL10 VID[0]/MSID[0] CMOS O AM7 QPI1_DRX_DN[18] QPI I AL11 VSS GND AM8 QPI1_DRX_DP[19] QPI I AL12 VCC PWR AM9 VSS GND AL13 VCC PWR AM10 VID[3]/CSC[0] CMOS O AL14 VSS GND AM11 VSS GND ® ® 70 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 9 of 35) (Sheet 10 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AM12 VCC PWR AN9 VID[2]/MSID[2] CMOS O AM13 VCC PWR AN10 VID[4]/CSC[1] CMOS O AM14 VSS GND AN11 VSS GND AM15 VCC PWR AN12 VCC PWR AM16 VCC PWR AN13 VCC PWR AM17 VSS GND AN14 VSS GND AM18 VCC PWR AN15 VCC PWR AM19 VCC PWR AN16 VCC PWR AM20 VSS GND AN17 VSS GND AM21 VCC PWR AN18 VCC PWR AM22 VSS GND AN19 VCC PWR AM23 VSS GND AN20 VSS GND AM24 VCC PWR AN21 VCC PWR AM25 VCC PWR AN22 VSS GND AM26 VSS GND AN23 VSS GND AM27 VCC PWR AN24 VCC PWR AM28 VCC PWR AN25 VCC PWR AM29 VSS GND AN26 VSS GND AM30 VCC PWR AN27 VCC PWR AM31 VCC PWR AN28 VCC PWR AM32 VSS GND AN29 VSS GND AM33 VCC PWR AN30 VCC PWR AM34 VCC PWR AN31 VCC PWR AM35 VSS GND AN32 VSS GND AM36 RSVD AN33 VCC PWR AM37 VSS GND AN34 VCC PWR AM38 RSVD AN35 VSS GND AM39 VSS GND AN36 RSVD AM40 QPI0_DRX_DN[15] QPI I AN37 VSS GND AM41 QPI0_DRX_DN[16] QPI I AN38 RSVD AM42 QPI0_DRX_DP[16] QPI I AN39 QPI0_DRX_DP[18] QPI I AM43 QPI0_DRX_DN[14] QPI I AN40 QPI0_DRX_DP[15] QPI I AN1 QPI1_DRX_DP[13] QPI I AN41 VSS GND AN2 QPI1_DRX_DN[12] QPI I AN42 QPI0_DRX_DN[13] QPI I AN3 VSS GND AN43 QPI0_DRX_DP[14] QPI I AN4 QPI1_DRX_DN[16] QPI I AP1 VSS GND AN5 QPI1_DRX_DP[17] QPI I AP2 QPI1_DRX_DP[12] QPI I AN6 QPI1_DRX_DN[17] QPI I AP3 QPI1_DRX_DP[15] QPI I AN7 VSS GND AP4 QPI1_DRX_DN[15] QPI I AN8 VID[7] CMOS O AP5 VSS GND ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 71 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 11 of 35) (Sheet 12 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AP6 VSS GND AR3 VSS GND AP7 PSI# CMOS O AR4 QPI1_DRX_DP[11] QPI I AP8 VID[6] CMOS O AR5 QPI1_DRX_DN[11] QPI I AP9 VID[5]/CSC[2] CMOS O AR6 QPI1_CLKRX_DN QPI I AP10 VSS GND AR7 VCCPWRGOOD Asynch I AP11 VSS GND AR8 VSS_SENSE Analog AP12 VCC PWR AR9 VCC_SENSE Analog AP13 VCC PWR AR10 VCC PWR AP14 VSS GND AR11 VSS GND AP15 VCC PWR AR12 VCC PWR AP16 VCC PWR AR13 VCC PWR AP17 VSS GND AR14 VSS GND AP18 VCC PWR AR15 VCC PWR AP19 VCC PWR AR16 VCC PWR AP20 VSS GND AR17 VSS GND AP21 VCC PWR AR18 VCC PWR AP22 VSS GND AR19 VCC PWR AP23 VSS GND AR20 VSS GND AP24 VCC PWR AR21 VCC PWR AP25 VCC PWR AR22 VSS GND AP26 VSS GND AR23 VSS GND AP27 VCC PWR AR24 VCC PWR AP28 VCC PWR AR25 VCC PWR AP29 VSS GND AR26 VSS GND AP30 VCC PWR AR27 VCC PWR AP31 VCC PWR AR28 VCC PWR AP32 VSS GND AR29 VSS GND AP33 VCC PWR AR30 VCC PWR AP34 VCC PWR AR31 VCC PWR AP35 VSS GND AR32 VSS GND AP36 VSS GND AR33 VCC PWR AP37 VSS GND AR34 VCC PWR AP38 QPI0_DRX_DP[19] QPI I AR35 VSS GND AP39 QPI0_DRX_DN[18] QPI I AR36 RSVD AP40 QPI0_DRX_DN[17] QPI I AR37 RSVD AP41 QPI0_DRX_DP[17] QPI I AR38 QPI0_DRX_DN[19] QPI I AP42 QPI0_DRX_DP[13] QPI I AR39 VSS GND AP43 VSS GND AR40 QPI0_DRX_DN[12] QPI I AR1 QPI1_DRX_DN[10] QPI I AR41 QPI0_CLKRX_DP QPI I AR2 VSS GND AR42 QPI0_CLKRX_DN QPI I ® ® 72 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 13 of 35) (Sheet 14 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AR43 QPI0_DRX_DN[11] QPI I AT40 QPI0_DRX_DP[12] QPI I AT1 QPI1_DRX_DP[10] QPI I AT41 VSS GND AT2 QPI1_DRX_DN[9] QPI I AT42 QPI0_DRX_DN[10] QPI I AT3 QPI1_DRX_DP[9] QPI I AT43 QPI0_DRX_DP[11] QPI I AT4 RSVD AU1 VSS GND AT5 RSVD AU2 RSVD AT6 QPI1_CLKRX_DP QPI I AU3 QPI1_DRX_DN[8] QPI I AT7 VSS GND AU4 QPI1_DRX_DP[8] QPI I AT8 VSS GND AU5 VSS GND AT9 VCC PWR AU6 QPI1_DRX_DN[6] QPI I AT10 VCC PWR AU7 QPI1_DRX_DP[6] QPI I AT11 VSS GND AU8 QPI1_DRX_DP[0] QPI I AT12 VCC PWR AU9 VCC PWR AT13 VCC PWR AU10 VCC PWR AT14 VSS GND AU11 VSS GND AT15 VCC PWR AU12 VCC PWR AT16 VCC PWR AU13 VCC PWR AT17 VSS GND AU14 VSS GND AT18 VCC PWR AU15 VCC PWR AT19 VCC PWR AU16 VCC PWR AT20 VSS GND AU17 VSS GND AT21 VCC PWR AU18 VCC PWR AT22 VSS GND AU19 VCC PWR AT23 VSS GND AU20 VSS GND AT24 VCC PWR AU21 VCC PWR AT25 VCC PWR AU22 VSS GND AT26 VSS GND AU23 VSS GND AT27 VCC PWR AU24 VCC PWR AT28 VCC PWR AU25 VCC PWR AT29 VSS GND AU26 VSS GND AT30 VCC PWR AU27 VCC PWR AT31 VCC PWR AU28 VCC PWR AT32 VSS GND AU29 VSS GND AT33 VCC PWR AU30 VCC PWR AT34 VCC PWR AU31 VCC PWR AT35 VSS GND AU32 VSS GND AT36 RSVD AU33 VCC PWR AT37 QPI0_DRX_DP[0] QPI I AU34 VCC PWR AT38 VSS GND AU35 VSS GND AT39 QPI0_DRX_DN[7] QPI I AU36 VSS GND ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 73 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 15 of 35) (Sheet 16 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AU37 QPI0_DRX_DN[0] QPI I AV34 VCC PWR AU38 QPI0_DRX_DP[1] QPI I AV35 RSVD AU39 QPI0_DRX_DP[7] QPI I AV36 QPI0_DRX_DP[2] QPI I AU40 QPI0_DRX_DP[9] QPI I AV37 QPI0_DRX_DN[2] QPI I AU41 QPI0_DRX_DN[9] QPI I AV38 QPI0_DRX_DN[1] QPI I AU42 QPI0_DRX_DP[10] QPI I AV39 VSS GND AU43 VSS GND AV40 QPI0_DRX_DN[8] QPI I AV1 RSVD AV41 VSS GND AV2 RSVD AV42 RSVD AV3 VTT_VID2 CMOS O AV43 RSVD AV4 VSS GND AW1 VSS GND AV5 QPI1_DRX_DP[3] QPI I AW2 RSVD AV6 VTT_VID4 CMOS O AW3 QPI1_DRX_DN[7] QPI I AV7 QPI1_DRX_DP[1] QPI I AW4 QPI1_DRX_DP[7] QPI I AV8 QPI1_DRX_DN[0] QPI I AW5 QPI1_DRX_DN[3] QPI I AV9 VCC PWR AW6 VSS GND AV10 VCC PWR AW7 QPI1_DRX_DN[1] QPI I AV11 VSS GND AW8 VSS GND AV12 VCC PWR AW9 VCC PWR AV13 VCC PWR AW10 VCC PWR AV14 VSS GND AW11 VSS GND AV15 VCC PWR AW12 VCC PWR AV16 VCC PWR AW13 VCC PWR AV17 VSS GND AW14 VSS GND AV18 VCC PWR AW15 VCC PWR AV19 VCC PWR AW16 VCC PWR AV20 VSS GND AW17 VSS GND AV21 VCC PWR AW18 VCC PWR AV22 VSS GND AW19 VCC PWR AV23 VSS GND AW20 VSS GND AV24 VCC PWR AW21 VCC PWR AV25 VCC PWR AW22 VSS GND AV26 VSS GND AW23 VSS GND AV27 VCC PWR AW24 VCC PWR AV28 VCC PWR AW25 VCC PWR AV29 VSS GND AW26 VSS GND AV30 VCC PWR AW27 VCC PWR AV31 VCC PWR AW28 VCC PWR AV32 VSS GND AW29 VSS GND AV33 VCC PWR AW30 VCC PWR ® ® 74 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 17 of 35) (Sheet 18 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type AW31 VCC PWR AY30 VCC PWR AW32 VSS GND AY31 VCC PWR AW33 VCC PWR AY32 VSS GND AW34 VCC PWR AY33 VCC PWR AW35 VSS GND AY34 VCC PWR AW36 QPI0_DRX_DP[3] QPI I AY35 RSVD AW37 QPI0_DRX_DP[5] QPI I AY36 QPI0_DRX_DN[3] QPI I AW38 QPI0_DRX_DN[5] QPI I AY37 VSS GND AW39 RSVD AY38 QPI0_DRX_DN[6] QPI I AW40 QPI0_DRX_DP[8] QPI I AY39 RSVD AW41 RSVD AY40 RSVD AW42 RSVD AY41 RSVD AY2 VSS GND AY42 VSS GND AY3 RSVD B2 VSS GND AY4 RSVD B3 BPM#[0] GTL I/O AY5 QPI1_DRX_DN[5] QPI I B4 BPM#[3] GTL I/O AY6 QPI1_DRX_DP[5] QPI I B5 DDR0_DQ[32] CMOS I/O AY7 VSS GND B6 DDR0_DQ[36] CMOS I/O AY8 QPI1_DRX_DP[2] QPI I B7 VDDQ PWR AY9 VCC PWR B8 DDR0_CS#[7]/ CMOS O DDR0_ODT[5] AY10 VCC PWR B9 DDR0_CS#[3] CMOS O AY11 VSS GND B10 DDR0_CS#[1] CMOS O AY12 VCC PWR B11 DDR0_ODT[2] CMOS O AY13 VCC PWR B12 VDDQ PWR AY14 VSS GND B13 DDR0_WE# CMOS O AY15 VCC PWR B14 DDR1_MA[13] CMOS O AY16 VCC PWR B15 DDR0_CS#[4] CMOS O AY17 VSS GND B16 DDR0_BA[0] CMOS O AY18 VCC PWR B17 VDDQ PWR AY19 VCC PWR B18 DDR2_MA_PAR CMOS O AY20 VSS GND B19 DDR0_MA[10] CMOS O AY21 VCC PWR B20 DDR0_MA_PAR CMOS O AY22 VSS GND B21 DDR0_MA[1] CMOS O AY23 VSS GND B22 VDDQ PWR AY24 VCC PWR B23 DDR0_MA[4] CMOS O AY25 VCC PWR B24 DDR0_MA[5] CMOS O AY26 VSS GND B25 DDR0_MA[8] CMOS O AY27 VCC PWR B26 DDR0_MA[12] CMOS O AY28 VCC PWR B27 VDDQ PWR AY29 VSS GND B28 DDR0_PAR_ERR#[1] Asynch I ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 75 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 19 of 35) (Sheet 20 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type B29 DDR0_MA[15] CMOS O BA36 QPI0_DRX_DP[4] QPI I B30 DDR0_CKE[2] CMOS O BA37 QPI0_DRX_DN[4] QPI I B31 DDR0_CKE[3] CMOS O BA38 QPI0_DRX_DP[6] QPI I B32 VDDQ PWR BA39 VSS GND B33 RSVD BA40 RSVD B34 DDR0_ECC[6] CMOS I/O C2 BPM#[2] GTL I/O B35 DDR0_DQS_N[17] CMOS I/O C3 BPM#[5] GTL I/O B36 DDR0_DQS_P[17] CMOS I/O C4 DDR0_DQ[33] CMOS I/O B37 VSS GND C5 VSS GND B38 DDR0_DQ[31] CMOS I/O C6 DDR0_DQ[37] CMOS I/O B39 DDR0_DQS_P[3] CMOS I/O C7 DDR0_ODT[3] CMOS O B40 DDR0_DQS_N[3] CMOS I/O C8 DDR1_ODT[1] CMOS O B41 PRDY# GTL O C9 DDR0_ODT[1] CMOS O B42 VSS GND C10 VDDQ PWR BA3 VSS GND C11 DDR0_CS#[6]/ CMOS O DDR0_ODT[4] BA4 RSVD C12 DDR0_CAS# CMOS O BA5 VSS GND C13 DDR0_CS#[2] CMOS O BA6 QPI1_DRX_DN[4] QPI I C14 DDR1_CS#[6]/ CMOS O BA7 QPI1_DRX_DP[4] QPI I DDR1_ODT[4] BA8 QPI1_DRX_DN[2] QPI I C15 VDDQ PWR BA9 VCC PWR C16 DDR2_WE# CMOS O BA10 VCC PWR C17 DDR1_CS#[4] CMOS O BA11 VSS GND C18 DDR1_BA[0] CMOS O BA12 VCC PWR C19 DDR0_CLK_N[1] CLOCK O BA13 VCC PWR C20 VDDQ PWR BA14 VSS GND C21 DDR1_CLK_P[0] CLOCK O BA15 VCC PWR C22 DDR1_PAR_ERR#[0] Asynch I BA16 VCC PWR C23 DDR0_MA[2] CMOS O BA17 VSS GND C24 DDR0_MA[6] CMOS O BA18 VCC PWR C25 VDDQ PWR BA19 VCC PWR C26 DDR0_MA[9] CMOS O BA20 VSS GND C27 DDR1_CKE[3] CMOS O BA24 VCC PWR C28 DDR0_BA[2] CMOS O BA25 VCC PWR C29 DDR0_CKE[0] CMOS O BA26 VSS GND C30 VDDQ PWR BA27 VCC PWR C31 RSVD BA28 VCC PWR C32 RSVD BA29 VSS GND C33 DDR0_ECC[3] CMOS I/O BA30 VCC PWR C34 DDR0_ECC[7] CMOS I/O BA35 VSS GND C35 VSS GND ® ® 76 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 21 of 35) (Sheet 22 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type C36 DDR0_ECC[0] CMOS I/O D33 VSS GND C37 DDR0_ECC[4] CMOS I/O D34 DDR0_DQS_P[8] CMOS I/O C38 DDR0_DQ[30] CMOS I/O D35 DDR0_DQS_N[8] CMOS I/O C39 DDR0_DQS_N[12] CMOS I/O D36 DDR1_ECC[0] CMOS I/O C40 VSS GND D37 DDR0_DQ[27] CMOS I/O C41 DDR0_DQ[25] CMOS I/O D38 VSS GND C42 PREQ# GTL I D39 DDR0_DQS_P[12] CMOS I/O C43 VSS GND D40 DDR0_DQ[24] CMOS I/O D1 BPM#[4] GTL I/O D41 DDR0_DQ[28] CMOS I/O D2 BPM#[6] GTL I/O D42 DDR0_DQ[29] CMOS I/O D3 VSS GND D43 VSS GND D4 DDR0_DQS_N[13] CMOS I/O E1 VSS GND D5 DDR0_DQS_P[13] CMOS I/O E2 BPM#[7] GTL I/O D6 DDR1_DQ[38] CMOS I/O E3 DDR0_DQS_P[4] CMOS I/O D7 DDR1_DQS_N[4] CMOS I/O E4 DDR0_DQS_N[4] CMOS I/O D8 VSS GND E5 DDR1_DQ[34] CMOS I/O D9 DDR2_CS#[5] CMOS O E6 VSS GND D10 DDR2_ODT[3] CMOS O E7 DDR1_DQS_P[4] CMOS I/O D11 DDR1_ODT[0] CMOS O E8 DDR1_DQ[33] CMOS I/O D12 DDR1_CS#[0] CMOS O E9 DDR1_DQ[32] CMOS I/O D13 VDDQ PWR E10 DDR1_CS#[5] CMOS O D14 DDR1_ODT[2] CMOS O E11 VDDQ PWR D15 DDR2_ODT[2] CMOS O E12 DDR1_CS#[7]/ CMOS O DDR1_ODT[5] D16 DDR2_CS#[2] CMOS O E13 DDR1_CS#[3] CMOS O D17 DDR2_RAS# CMOS O E14 DDR1_CAS# CMOS O D18 VDDQ PWR E15 DDR1_CS#[2] CMOS O D19 DDR0_CLK_P[1] CLOCK O E16 VDDQ PWR D20 DDR1_MA_PAR CMOS O E17 DDR2_CS#[4] CMOS O D21 DDR1_CLK_N[0] CLOCK O E18 DDR0_CLK_N[2] CLOCK O D22 DDR1_MA[7] CMOS O E19 DDR0_CLK_N[3] CLOCK O D23 VDDQ PWR E20 DDR0_CLK_P[3] CLOCK O D24 DDR0_MA[3] CMOS O E21 VDDQ PWR D25 DDR0_PAR_ERR#[0] Asynch I E22 DDR1_MA[8] CMOS O D26 DDR2_CKE[2] CMOS O E23 DDR1_MA[11] CMOS O D27 DDR1_CKE[2] CMOS O E24 DDR1_MA[12] CMOS O D28 VDDQ PWR E25 DDR1_PAR_ERR#[1] Asynch I D29 DDR1_RESET# CMOS O E26 VDDQ PWR D30 RSVD E27 DDR1_CKE[1] CMOS O D31 RSVD E28 RSVD D32 DDR0_RESET# CMOS O E29 DDR2_ECC[2] CMOS I/O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 77 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 23 of 35) (Sheet 24 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type E30 DDR2_ECC[3] CMOS I/O F27 RSVD E31 VDDQ PWR F28 RSVD E32 DDR2_RESET# CMOS O F29 VSS GND E33 DDR1_ECC[2] CMOS I/O F30 DDR2_ECC[7] CMOS I/O E34 DDR1_ECC[6] CMOS I/O F31 DDR2_ECC[6] CMOS I/O E35 DDR1_DQS_N[17] CMOS I/O F32 DDR0_ECC[2] CMOS I/O E36 VSS GND F33 DDR2_ECC[1] CMOS I/O E37 DDR1_ECC[4] CMOS I/O F34 VSS GND E38 DDR2_DQ[31] CMOS I/O F35 DDR1_DQS_P[17] CMOS I/O E39 DDR2_DQS_P[3] CMOS I/O F36 DDR1_ECC[1] CMOS I/O E40 DDR2_DQS_N[3] CMOS I/O F37 DDR1_ECC[5] CMOS I/O E41 VSS GND F38 DDR2_DQ[30] CMOS I/O E42 DDR0_DQ[18] CMOS I/O F39 VSS GND E43 DDR0_DQ[19] CMOS I/O F40 DDR2_DQ[25] CMOS I/O F1 DDR0_DQ[34] CMOS I/O F41 DDR0_DQS_P[2] CMOS I/O F2 DDR0_DQ[39] CMOS I/O F42 DDR0_DQ[23] CMOS I/O F3 DDR0_DQ[38] CMOS I/O F43 DDR0_DQ[22] CMOS I/O F4 VSS GND G1 DDR0_DQ[44] CMOS I/O F5 DDR1_DQ[35] CMOS I/O G2 VSS GND F6 DDR1_DQ[39] CMOS I/O G3 DDR0_DQ[35] CMOS I/O F7 DDR1_DQS_N[13] CMOS I/O G4 DDR1_DQ[42] CMOS I/O F8 DDR1_DQS_P[13] CMOS I/O G5 DDR1_DQ[46] CMOS I/O F9 VSS GND G6 DDR1_DQS_N[5] CMOS I/O F10 DDR1_DQ[36] CMOS I/O G7 VSS GND F11 DDR1_ODT[3] CMOS O G8 DDR1_DQ[37] CMOS I/O F12 DDR0_ODT[0] CMOS O G9 DDR1_DQ[44] CMOS I/O F13 DDR2_ODT[1] CMOS O G10 DDR2_DQ[37] CMOS I/O F14 VDDQ PWR G11 DDR2_DQ[36] CMOS I/O F15 DDR2_MA[13] CMOS O G12 VSS GND F16 DDR2_CAS# CMOS O G13 DDR1_WE# CMOS O F17 DDR2_BA[1] CMOS O G14 DDR1_RAS# CMOS O F18 DDR0_CLK_P[2] CLOCK O G15 DDR0_CS#[0] CMOS O F19 VDDQ PWR G16 DDR2_CS#[0] CMOS O F20 DDR2_MA[4] CMOS O G17 VDDQ PWR F21 DDR2_PAR_ERR#[0] Asynch I G18 DDR2_MA[2] CMOS O F22 DDR1_MA[5] CMOS O G19 DDR1_CLK_P[1] CLOCK O F23 DDR2_PAR_ERR#[2] Asynch I G20 DDR1_CLK_N[1] CLOCK O F24 VDDQ PWR G21 DDR2_CLK_N[2] CLOCK O F25 DDR1_PAR_ERR#[2] Asynch I G22 VDDQ PWR F26 DDR1_MA[15] CMOS O G23 DDR2_MA[12] CMOS O ® ® 78 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 25 of 35) (Sheet 26 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type G24 DDR1_MA[9] CMOS O H21 DDR2_CLK_P[2] CLOCK O G25 DDR2_MA[15] CMOS O H22 DDR2_MA[9] CMOS O G26 DDR2_CKE[1] CMOS O H23 DDR2_MA[11] CMOS O G27 VDDQ PWR H24 DDR2_MA[14] CMOS O G28 RSVD H25 VDDQ PWR G29 DDR2_DQS_P[8] CMOS I/O H26 DDR1_MA[14] CMOS O G30 DDR2_DQS_N[8] CMOS I/O H27 DDR1_BA[2] CMOS O G31 DDR2_DQS_N[17] CMOS I/O H28 DDR1_CKE[0] CMOS O G32 VSS GND H29 RSVD G33 DDR1_DQS_P[8] CMOS I/O H30 VSS GND G34 DDR1_DQS_N[8] CMOS I/O H31 DDR2_DQS_P[17] CMOS I/O G35 DDR1_ECC[7] CMOS I/O H32 DDR2_ECC[0] CMOS I/O G36 DDR1_ECC[3] CMOS I/O H33 DDR1_DQ[24] CMOS I/O G37 VSS GND H34 DDR1_DQ[29] CMOS I/O G38 DDR2_DQS_N[12] CMOS I/O H35 VSS GND G39 DDR2_DQ[29] CMOS I/O H36 DDR1_DQ[23] CMOS I/O G40 DDR2_DQ[24] CMOS I/O H37 DDR2_DQ[27] CMOS I/O G41 DDR0_DQS_N[2] CMOS I/O H38 DDR2_DQS_P[12] CMOS I/O G42 VSS GND H39 DDR2_DQ[28] CMOS I/O G43 DDR0_DQS_N[11] CMOS I/O H40 VSS GND H1 DDR0_DQ[41] CMOS I/O H41 DDR0_DQ[16] CMOS I/O H2 DDR0_DQ[40] CMOS I/O H42 DDR0_DQS_P[11] CMOS I/O H3 DDR0_DQ[45] CMOS I/O H43 DDR0_DQ[17] CMOS I/O H4 DDR1_DQ[43] CMOS I/O J1 DDR0_DQS_N[14] CMOS I/O H5 VSS GND J2 DDR0_DQS_P[14] CMOS I/O H6 DDR1_DQS_P[5] CMOS I/O J3 VSS GND H7 DDR1_DQS_P[14] CMOS I/O J4 DDR1_DQ[52] CMOS I/O H8 DDR1_DQ[40] CMOS I/O J5 DDR1_DQ[47] CMOS I/O H9 DDR1_DQ[45] CMOS I/O J6 DDR1_DQ[41] CMOS I/O H10 VSS GND J7 DDR1_DQS_N[14] CMOS I/O H11 DDR2_DQS_P[13] CMOS I/O J8 VSS GND H12 DDR2_DQ[38] CMOS I/O J9 DDR2_DQS_N[4] CMOS I/O H13 DDR2_DQ[34] CMOS I/O J10 DDR2_DQS_P[4] CMOS I/O H14 DDR1_MA[10] CMOS O J11 DDR2_DQS_N[13] CMOS I/O H15 VDDQ PWR J12 DDR2_DQ[33] CMOS I/O H16 DDR2_CS#[3] CMOS O J13 VSS GND H17 DDR2_MA[10] CMOS O J14 DDR1_MA[0] CMOS O H18 DDR1_CLK_P[3] CLOCK O J15 DDR2_CS#[7]/ CMOS O DDR2_ODT[5] H19 DDR1_CLK_N[3] CLOCK O J16 DDR1_MA[1] CMOS O H20 VDDQ PWR J17 DDR1_MA[2] CMOS O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 79 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 27 of 35) (Sheet 28 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type J18 VDDQ PWR K15 RSVD J19 DDR0_CLK_P[0] CLOCK O K16 VDDQ PWR J20 DDR2_MA[3] CMOS O K17 DDR2_MA[1] CMOS O J21 DDR2_CLK_N[0] CLOCK O K18 DDR1_CLK_P[2] CLOCK O J22 DDR2_CLK_P[0] CLOCK O K19 DDR0_CLK_N[0] CLOCK O J23 VDDQ PWR K20 DDR2_CLK_N[1] CLOCK O J24 DDR2_MA[7] CMOS O K21 VDDQ PWR J25 DDR2_PAR_ERR#[1] Asynch I K22 DDR2_MA[6] CMOS O J26 DDR2_CKE[0] CMOS O K23 DDR2_MA[5] CMOS O J27 DDR1_MA[6] CMOS O K24 RSVD J28 VDDQ PWR K25 RSVD J29 RSVD K26 VDDQ PWR J30 DDR2_ECC[5] CMOS I/O K27 RSVD J31 DDR2_ECC[4] CMOS I/O K28 DDR1_MA[4] CMOS O J32 DDR1_DQ[27] CMOS I/O K29 RSVD J33 VSS GND K30 DDR1_DQ[31] CMOS I/O J34 DDR1_DQ[28] CMOS I/O K31 VSS GND J35 DDR1_DQ[19] CMOS I/O K32 DDR1_DQ[26] CMOS I/O J36 DDR1_DQ[22] CMOS I/O K33 DDR1_DQS_N[12] CMOS I/O J37 DDR2_DQ[26] CMOS I/O K34 DDR1_DQS_P[12] CMOS I/O J38 VSS GND K35 DDR1_DQ[18] CMOS I/O J39 DDR2_DQ[19] CMOS I/O K36 VSS GND J40 DDR2_DQ[18] CMOS I/O K37 DDR1_DQS_N[11] CMOS I/O J41 DDR0_DQ[21] CMOS I/O K38 DDR2_DQ[23] CMOS I/O J42 DDR0_DQ[20] CMOS I/O K39 DDR2_DQS_N[2] CMOS I/O J43 VSS GND K40 DDR2_DQS_P[2] CMOS I/O K1 VSS GND K41 VSS GND K2 DDR0_DQS_P[5] CMOS I/O K42 DDR0_DQ[10] CMOS I/O K3 DDR0_DQS_N[5] CMOS I/O K43 DDR0_DQ[11] CMOS I/O K4 DDR1_DQ[48] CMOS I/O L1 DDR0_DQ[42] CMOS I/O K5 DDR1_DQ[49] CMOS I/O L2 DDR0_DQ[47] CMOS I/O K6 VSS GND L3 DDR0_DQ[46] CMOS I/O K7 DDR2_DQS_N[5] CMOS I/O L4 VSS GND K8 DDR2_DQS_N[14] CMOS I/O L5 DDR1_DQS_N[6] CMOS I/O K9 DDR2_DQS_P[14] CMOS I/O L6 DDR1_DQS_P[6] CMOS I/O K10 DDR2_DQ[41] CMOS I/O L7 DDR2_DQS_P[5] CMOS I/O K11 VSS GND L8 DDR2_DQ[46] CMOS I/O K12 DDR2_DQ[32] CMOS I/O L9 VSS GND K13 DDR1_BA[1] CMOS O L10 DDR2_DQ[40] CMOS I/O K14 DDR2_CS#[1] CMOS O L11 DDR2_DQ[44] CMOS I/O ® ® 80 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 29 of 35) (Sheet 30 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type L12 DDR2_DQ[39] CMOS I/O M9 DDR2_DQ[42] CMOS I/O L13 DDR2_DQ[35] CMOS I/O M10 DDR2_DQ[45] CMOS I/O L14 VDDQ PWR M11 VCC PWR L15 RSVD M12 VSS GND L16 DDR2_ODT[0] CMOS O M13 VCC PWR L17 DDR2_CS#[6]/ CMOS O M14 VSS GND DDR2_ODT[4] M15 VCC PWR L18 DDR1_CLK_N[2] CLOCK O M16 VSS GND L19 VDDQ PWR M17 VDDQ PWR L20 DDR2_CLK_P[1] CLOCK O M18 VSS GND L21 DDR2_CLK_N[3] CLOCK O M19 VCC PWR L22 DDR2_CLK_P[3] CLOCK O M20 VSS GND L23 DDR_VREF Analog I M21 VCC PWR L24 VDDQ PWR M22 VSS GND L25 DDR2_MA[8] CMOS O M23 VCC PWR L26 DDR2_BA[2] CMOS O M24 VSS GND L27 DDR2_CKE[3] CMOS O M25 VCC PWR L28 DDR1_MA[3] CMOS O M26 VSS GND L29 VSS GND M27 VDDQ PWR L30 DDR1_DQS_P[3] CMOS I/O M28 VSS GND L31 DDR1_DQS_N[3] CMOS I/O M29 VCC PWR L32 DDR1_DQ[30] CMOS I/O M30 VSS GND L33 DDR1_DQ[25] CMOS I/O M31 VCC PWR L34 VSS GND M32 VSS GND L35 DDR1_DQS_P[2] CMOS I/O M33 VCC PWR L36 DDR1_DQS_N[2] CMOS I/O M34 DDR1_DQ[17] CMOS I/O L37 DDR1_DQS_P[11] CMOS I/O M35 DDR1_DQ[16] CMOS I/O L38 DDR2_DQS_N[11] CMOS I/O M36 DDR1_DQ[21] CMOS I/O L39 VSS GND M37 VSS GND L40 DDR2_DQ[22] CMOS I/O M38 DDR2_DQS_P[11] CMOS I/O L41 DDR0_DQS_P[1] CMOS I/O M39 DDR2_DQ[16] CMOS I/O L42 DDR0_DQ[15] CMOS I/O M40 DDR2_DQ[17] CMOS I/O L43 DDR0_DQ[14] CMOS I/O M41 DDR0_DQS_N[1] CMOS I/O M1 DDR0_DQ[43] CMOS I/O M42 VSS GND M2 VSS GND M43 DDR0_DQS_N[10] CMOS I/O M3 DDR0_DQ[52] CMOS I/O N1 DDR0_DQ[48] CMOS I/O M4 DDR1_DQS_N[15] CMOS I/O N2 DDR0_DQ[49] CMOS I/O M5 DDR1_DQS_P[15] CMOS I/O N3 DDR0_DQ[53] CMOS I/O M6 DDR1_DQ[53] CMOS I/O N4 DDR2_DQS_P[15] CMOS I/O M7 VSS GND N5 VSS GND M8 DDR2_DQ[47] CMOS I/O ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 81 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 31 of 35) (Sheet 32 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type N6 DDR2_DQ[49] CMOS I/O R2 DDR0_DQS_P[6] CMOS I/O N7 DDR2_DQ[53] CMOS I/O R3 DDR0_DQS_N[6] CMOS I/O N8 DDR2_DQ[52] CMOS I/O R4 DDR0_DQ[54] CMOS I/O N9 DDR2_DQ[43] CMOS I/O R5 DDR1_DQ[50] CMOS I/O N10 VSS GND R6 VSS GND N11 VCC PWR R7 DDR1_DQ[55] CMOS I/O N33 VCC PWR R8 DDR1_DQ[54] CMOS I/O N34 DDR1_DQ[20] CMOS I/O R9 DDR2_DQ[55] CMOS I/O N35 VSS GND R10 DDR2_DQ[54] CMOS I/O N36 DDR2_DQ[21] CMOS I/O R11 VCC PWR N37 DDR1_DQ[14] CMOS I/O R33 VCC PWR N38 DDR1_DQ[15] CMOS I/O R34 DDR1_DQ[12] CMOS I/O N39 DDR1_DQ[11] CMOS I/O R35 DDR1_DQ[13] CMOS I/O N40 VSS GND R36 VSS GND N41 DDR0_DQ[8] CMOS I/O R37 DDR1_DQS_N[1] CMOS I/O N42 DDR0_DQS_P[10] CMOS I/O R38 DDR1_DQS_P[1] CMOS I/O N43 DDR0_DQ[9] CMOS I/O R39 DDR2_DQ[10] CMOS I/O P1 DDR0_DQS_N[15] CMOS I/O R40 DDR2_DQ[15] CMOS I/O P2 DDR0_DQS_P[15] CMOS I/O R41 VSS GND P3 VSS GND R42 DDR0_DQ[3] CMOS I/O P4 DDR2_DQS_N[15] CMOS I/O R43 DDR0_DQ[2] CMOS I/O P5 DDR2_DQS_N[6] CMOS I/O T1 DDR0_DQ[50] CMOS I/O P6 DDR2_DQS_P[6] CMOS I/O T2 DDR0_DQ[51] CMOS I/O P7 DDR2_DQ[48] CMOS I/O T3 DDR0_DQ[55] CMOS I/O P8 VSS GND T4 VSS GND P9 DDR2_DQ[50] CMOS I/O T5 DDR1_DQ[51] CMOS I/O P10 DDR2_DQ[51] CMOS I/O T6 DDR2_DQ[60] CMOS I/O P11 VSS GND T7 DDR2_DQ[61] CMOS I/O P33 VSS GND T8 DDR2_DQS_N[7] CMOS I/O P34 DDR1_DQ[8] CMOS I/O T9 VSS GND P35 DDR1_DQ[9] CMOS I/O T10 DDR2_DQ[58] CMOS I/O P36 DDR1_DQS_P[10] CMOS I/O T11 VCC PWR P37 DDR1_DQS_N[10] CMOS I/O T33 VCC PWR P38 VSS GND T34 VSS GND P39 DDR1_DQ[10] CMOS I/O T35 DDR2_DQS_N[9] CMOS I/O P40 DDR2_DQ[20] CMOS I/O T36 DDR2_DQ[11] CMOS I/O P41 DDR0_DQ[13] CMOS I/O T37 DDR2_DQS_P[1] CMOS I/O P42 DDR0_DQ[12] CMOS I/O T38 DDR2_DQS_N[1] CMOS I/O P43 VSS GND T39 VSS GND R1 VSS GND T40 DDR2_DQS_N[10] CMOS I/O ® ® 82 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Land Listing Table 4-2. Land Listing by Land Number Table 4-2. Land Listing by Land Number (Sheet 33 of 35) (Sheet 34 of 35) Land Buffer Land Buffer Land Name Direction Land Name Direction No. Type No. Type T41 DDR2_DQ[14] CMOS I/O V37 DDR2_DQ[6] CMOS I/O T42 DDR0_DQ[7] CMOS I/O V38 DDR2_DQ[7] CMOS I/O T43 DDR0_DQS_P[0] CMOS I/O V39 DDR2_DQ[13] CMOS I/O U1 DDR0_DQ[60] CMOS I/O V40 VSS GND U2 VSS GND V41 DDR0_DQ[1] CMOS I/O U3 DDR0_DQ[61] CMOS I/O V42 DDR0_DQS_N[9] CMOS I/O U4 DDR0_DQ[56] CMOS I/O V43 DDR0_DQS_P[9] CMOS I/O U5 DDR2_DQ[56] CMOS I/O W1 DDR0_DQS_N[7] CMOS I/O U6 DDR2_DQ[57] CMOS I/O W2 DDR0_DQS_P[7] CMOS I/O U7 VSS GND W3 VSS GND U8 DDR2_DQS_P[7] CMOS I/O W4 DDR0_DQ[63] CMOS I/O U9 DDR2_DQ[63] CMOS I/O W5 DDR1_DQ[61] CMOS I/O U10 DDR2_DQ[59] CMOS I/O W6 DDR1_DQ[56] CMOS I/O U11 RSVD W7 DDR1_DQ[57] CMOS I/O U33 VCCPLL PWR W8 VSS GND U34 DDR2_DQ[4] CMOS I/O W9 DDR1_DQ[63] CMOS I/O U35 DDR2_DQS_P[9] CMOS I/O W10 DDR1_DQ[59] CMOS I/O U36 DDR2_DQ[3] CMOS I/O W11 VCC PWR U37 VSS GND W33 VCCPLL PWR U38 DDR2_DQ[8] CMOS I/O W34 DDR2_DQ[0] CMOS I/O U39 DDR2_DQ[9] CMOS I/O W35 DDR2_DQ[1] CMOS I/O U40 DDR2_DQS_P[10] CMOS I/O W36 DDR2_DQS_N[0] CMOS I/O U41 DDR0_DQ[6] CMOS I/O W37 DDR2_DQS_P[0] CMOS I/O U42 VSS GND W38 VSS GND U43 DDR0_DQS_N[0] CMOS I/O W39 DDR2_DQ[12] CMOS I/O V1 DDR0_DQ[57] CMOS I/O W40 DDR0_DQ[4] CMOS I/O V2 DDR0_DQS_P[16] CMOS I/O W41 DDR0_DQ[0] CMOS I/O V3 DDR0_DQS_N[16] CMOS I/O W42 DDR0_DQ[5] CMOS I/O V4 DDR0_DQ[62] CMOS I/O W43 VSS GND V5 VSS GND Y1 VSS GND V6 DDR2_DQS_P[16] CMOS I/O Y2 DDR0_DQ[58] CMOS I/O V7 DDR2_DQS_N[16] CMOS I/O Y3 DDR0_DQ[59] CMOS I/O V8 DDR2_DQ[62] CMOS I/O Y4 DDR1_DQS_P[16] CMOS I/O V9 DDR1_DQ[60] CMOS I/O Y5 DDR1_DQS_N[16] CMOS I/O V10 VSS GND Y6 VSS GND V11 RSVD Y7 DDR_COMP[1] Analog V33 VCCPLL PWR Y8 DDR1_DQS_P[7] CMOS I/O V34 DDR2_DQ[5] CMOS I/O Y9 DDR1_DQS_N[7] CMOS I/O V35 VSS GND Y10 DDR1_DQ[58] CMOS I/O V36 DDR2_DQ[2] CMOS I/O Y11 VSS GND ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 83 Land Listing Table 4-2. Land Listing by Land Number (Sheet 35 of 35) Land Buffer Land Name Direction No. Type Y33 VSS GND Y34 DDR1_DQ[3] CMOS I/O Y35 DDR1_DQ[2] CMOS I/O Y36 VSS GND Y37 DDR1_DQS_N[0] CMOS I/O Y38 DDR1_DQS_P[0] CMOS I/O Y39 DDR1_DQ[7] CMOS I/O Y40 DDR1_DQ[6] CMOS I/O Y41 VSS GND § ® ® 84 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Signal Definitions 5 Signal Definitions 5.1 Signal Definitions Table 5-1. Signal Definitions (Sheet 1 of 4) Name Type Description Notes BCLK_DN I Differential bus clock input to the processor. BCLK_DP BCLK_ITP_DN O Buffered differential bus clock pair to ITP. BCLK_ITP_DP BPM#[7:0] I/O BPM#[7:0] are breakpoint and performance monitor signals. They are outputs from the processor which indicate the status of breakpoints and programmable counters used for monitoring processor performance. BPM#[7:0] should be connected in a wired OR topology between all packages on a platform. CAT_ERR# I/O Indicates that the system has experienced a catastrophic error and cannot continue to operate. The processor will set this for non-recoverable machine check errors other internal unrecoverable error. It is expected that every processor in the system will have this hooked up in a wired-OR configuration. Since this is an I/O pin, external agents are allowed to assert this pin which will cause the processor to take a machine check exception. On Intel Xeon processor 5500 series, CAT_ERR# is used for signalling the following types of errors: • Legacy MCERR’s, CAT_ERR# is pulsed for 16 BCLKs. • Legacy IERR’s, CAT_ERR remains asserted until warm or cold reset. COMP0 I Impedance Compensation must be terminated on the system board using precision resistor. QPI0_CLKRX_DN Intel QuickPath Interconnect received clock is the input clock that corresponds to I Intel QuickPath Interconnect port0 received data. QPI0_CLKRX_DP I QPI0_CLKTX_DN O Intel QuickPath Interconnect forwarded clock sent with Intel QuickPath Interconnect port 0 outbound data. QPI0_CLKTX_DP O QPI0_COMP I Must be terminated on the system board using precision resistor. QPI0_DRX_DN[19:0] I QPI0_DRX_DN[19:0] and QPI0_DRX_DP[19:0] comprise the differential receive data for Intel QuickPath Interconnect port0. The inbound 20 lanes are connected to QPI0_DRX_DP[19:0] I another component’s outbound lanes. QPI0_DTX_DN[19:0] O QPI0_DTX_DN[19:0] and QPI0_DTX_DP[19:0] comprise the differential transmit data for Intel QuickPath Interconnect port0. The outbound 20 lanes are connected QPI0_DTX_DP[19:0] O to another component’s inbound lanes. QPI1_CLKRX_DN I Intel QuickPath Interconnect received clock is the input clock that corresponds to Intel QuickPath Interconnect 1 port received data. QPI1_CLKRX_DP I QPI1_CLKTX_DN O Intel QuickPath Interconnect forwarded clock sent with Intel QuickPath Interconnect port1 outbound data. QPI1_CLKTX_DP O QPI1_COMP I Must be terminated on the system board using precision resistor. QPI1_DRX_DN[19:0] I QPI1_DRX_DN[19:0] and QPI1_DRX_DP[19:0] comprise the differential receive data for Intel QuickPath Interconnect port1. The inbound 20 lanes are connected to QPI1_DRX_DP[19:0] another component’s outbound lanes. I QPI1_DTX_DN[19:0] O QPI1_DTX_DN[19:0] and QPI1_DTX_DP[19:0] comprise the differential transmit data for Intel QuickPath Interconnect port1. The outbound 20 lanes are connected QPI1_DTX_DP[19:0] to another component’s inbound lanes. O DBR# I DBR# is used only in systems where no debug port is implemented on the system board. DBR# is used by a debug port interposer so that an in-target probe can drive system reset. DDR_COMP[2:0] I Must be terminated on the system board using precision resistors. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 85 Signal Definitions Table 5-1. Signal Definitions (Sheet 2 of 4) Name Type Description Notes DDR_THERM# I DDR_THERM# is used for imposing duty cycle throttling on all memory channels. The platform should ensure that DDR_THERM# is exerted when any DIMM is over T64 (85 °C) 1 DDR{0/1/2}_BA[2:0] O Defines the bank which is the destination for the current Activate, Read, Write, or Precharge command. DDR{0/1/2}_CAS# O Column Address Strobe. DDR{0/1/2}_CKE[3:0] O Clock Enable. DDR{0/1/ O Differential clocks to the DIMM. All command and control signals are valid on the 2}_CLK_N[3:0] rising edge of clock. DDR{0/1/ 2}_CLK_P[3:0] DDR{0/1/2}_CS[7:0]# O Each signal selects one rank as the target of the command and address. DDR{0/1/2}_DQ[63:0] I/O DDR3 Data bits. DDR{0/1/ I/O Differential pair, Data/ECC Strobe. Differential strobes latch data/ECC for each 2}_DQS_N[17:0] DRAM. Different numbers of strobes are used depending on whether the connected DRAMs are x4,x8. Driven with edges in center of data, receive edges are aligned DDR{0/1/ with data edges. 2}_DQS_P[17:0] DDR{0/1/2}_ECC[7:0] I/O Check Bits - An Error Correction Code is driven along with data on these lines for DIMMs that support that capability. DDR{0/1/2}_MA[15:0] O Selects the Row address for Reads and writes, and the column address for activates. Also used to set values for DRAM configuration registers. DDR{0/1/2}_MA_PAR O Odd parity across Address and Command. DDR{0/1/2}_ODT[3:0] O Enables various combinations of termination resistance in the target and non-target DIMMs when data is read or written DDR{0/1/ I Parity Error detected by Registered DIMM (one for each DIMM). 2}_PAR_ERR#[2:0] DDR{0/1/2}_RAS# O Row Address Strobe. DDR{0/1/2}_RESET# O Resets DRAMs. Held low on power up, held high during self refresh, otherwise controlled by configuration register. DDR_VREF I Voltage reference for DDR3. DDR{0/1/2}_WE# O Write Enable. GTLREF I Voltage reference for GTL signals. ISENSE I Current sense for VRD11.1. PECI I/O PECI (Platform Environment Control Interface) is the serial sideband interface to the processor and is used primarily for thermal, power and error management. PECI_ID# I PECI_ID# is the PECI client address identifier. Assertion of this pin results in a PECI client address of 0x31 (versus the default 0x30 client address). This pin is primarily useful for PECI client address differentiation in DP platforms. One of the two processors must be pulled down to VSS to strap to the address of 0x31. PRDY# O PRDY# is a processor output used by debug tools to determine processor debug readiness. PREQ# I/O PREQ# is used by debug tools to request debug operation of the processor. PROCHOT# I/O PROCHOT# will go active when the processor temperature monitoring sensor detects that the processor has reached its maximum safe operating temperature. This indicates that the processor Thermal Control Circuit has been activated, if enabled. This signal can also be driven to the processor to activate the Thermal Control Circuit. If PROCHOT# is asserted at the deassertion of RESET#, the processor will tri-state its outputs. This signal does not have on-die termination and must be terminated on the system board. ® ® 86 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Signal Definitions Table 5-1. Signal Definitions (Sheet 3 of 4) Name Type Description Notes PSI# O Processor Power Status Indicator signal. This signal is asserted when maximum possible processor core current consumption is less than 20A, Assertion of this signal is an indication that the VR controller does not currently need to be able to provide ICC above 20A, and the VR controller can use this information to move to more efficient operation point. This signal will de-assert at least 3.3 µs before the current consumption will exceed 20A. The minimum PSI# assertion time is 1 BCLK. The minimum PSI# de-assertion time is 3.3 us. This pin does not require a pull-down. For platforms which could experience false PSI# assertions during power-up if this pin is left floating, a pull-up may be used (1K-5K). Otherwise, it can be left floating. For boards currently pulling this signal to Vss, this is not a critical change to make immediately, but it is recommended for production builds. RESET# I Asserting the RESET# signal resets the processor to a known state and invalidates its internal caches without writing back any of their contents. Note some PLL, Intel QuickPath Interconnect and error states are not effected by reset and only VCCPWRGOOD forces them to a known state. For a power-on Reset, RESET# must stay active for at least one millisecond after VCC and BCLK have reached their proper specifications. RESET# must not be kept asserted for more than 10 ms while VCCPWRGOOD is asserted. RESET# must be held deasserted for at least one millisecond before it is asserted again. RESET# must be held asserted before VCCPWRGOOD is asserted. This signal does not have on-die termination and must be terminated on the system board. RESET# is a common clock signal. SKTOCC# O Socket occupied, platform must sense a VSS at this pin to enable POWER_ON. TCK I TCK (Test Clock) provides the clock input for the processor Test Bus (also known as the Test Access Port). TDI I TDI (Test Data In) transfers serial test data into the processor. TDI provides the serial input needed for JTAG specification support. TDO O TDO (Test Data Out) transfers serial test data out of the processor. TDO provides the serial output needed for JTAG specification support. THERMTRIP# O Assertion of THERMTRIP# (Thermal Trip) indicates the processor junction temperature has reached a level beyond which permanent silicon damage may occur. Measurement of the temperature is accomplished through an internal thermal sensor. Once activated, the processor will stop all execution and shut down all PLLs. To further protect the processor, its core voltage (V ), V V and V CC TTA TTD DDQ must be removed following the assertion of THERMTRIP#. Once activated, THERMTRIP# remains latched until RESET# is asserted. While the assertion of the RESET# signal may de-assert THERMTRIP#, if the processor's junction temperature remains at or above the trip level, THERMTRIP# will again be asserted after RESET# is de-asserted. TMS I TMS (Test Mode Select) is a JTAG specification support signal used by debug tools. TRST# I TRST# (Test Reset) resets the Test Access Port (TAP) logic. TRST# must be driven low during power on Reset. V O V and V provide an isolated, low impedance connection to the CC_SENSE CC_SENSE SS_SENSE processor core voltage and ground. They can used to sense or measure power near V O SS_SENSE the silicon with little noise. V I Power for processor core. CC VCCPWRGOOD I VCCPWRGOOD (Power Good) is a processor input. The processor requires this signal to be a clean indication that BCLK, V , V , V and V supplies are CC CCPLL TTA TTD stable and within their specifications. 'Clean' implies that the signal will remain low (capable of sinking leakage current), without glitches, from the time that the power supplies are turned on until they come within specification. The signal must then transition monotonically to a high state. VCCPWRGOOD can be driven inactive at any time, but BCLK and power must again be stable before a subsequent rising edge of VCCPWRGOOD. In addition at the time VCCPWRGOOD is asserted RESET# must be active. The PWRGOOD signal must be supplied to the processor; it is used to protect internal circuits against voltage sequencing issues. It should be driven high throughout boundary scan operation. V I Analog Power for Clocks. CCPLL V I Power supply for the DDR3 interface. DDQ ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 87 Signal Definitions Table 5-1. Signal Definitions (Sheet 4 of 4) Name Type Description Notes VTT_VID[4:2] O VTT_VID[4:2] is used to support automatic selection of power supply voltages (V ). The voltage supply for this signal must be valid before the VR can supply V TT TT to the processor. Conversely, the VR output must be disabled until the voltage supply for the VID signal become valid. The VID signal is needed to support the processor voltage specification variations. The VR must supply the voltage that is requested by the signal. V I Power for the analog portion of the Intel QuickPath Interconnect and Shared Cache. TTA V I Power for the digital portion of the Intel QuickPath Interconnect and Shared Cache. TTD VDDPWRGOOD I VDDPWRGOOD is an input that indicates the Vddq power supply is good. The processor requires this signal to be a clean indication that the Vddq power supply is stable and within their specifications. "Clean" implies that the signal will remain low (capable of sinking leakage current), without glitches, from the time that the Vddq supply is turned on until it come within specification. The signals must then transition monotonically to a high state. The PwrGood signal must be supplied to the processor, This signal is used to protect internal circuits against voltage sequencing issues. 2 VID[7:6] I/O VID[7:0] (Voltage ID) are output signals that are used to support automatic selection of power supply voltages (V ). The voltage supply for these signals must VID[5:3]/CSC[2:0] CC be valid before the VR can supply V to the processor. Conversely, the VR output CC VID[2:0]/MSID[2:0] must be disabled until the voltage supply for the VID signals become valid. The VID signals are needed to support the processor voltage specification variations. The VR must supply the voltage that is requested by the signals, or disable itself. VID7 and VID6 should be tied separately to V via 1kOhm resistors during reset SS (this value is latched on the rising edge of VTTPWRGOOD). MSID[2:0] - Market Segment ID, or MSID are provided to indicate the Market Segment for the processor and may be used for future processor compatibility or for keying. In addition, MSID protects the platform by preventing a higher power processor from booting in a platform designed for lower power processors. This value is latched from the platform in to the CPU, on the rising edge of VTTPWRGOOD, during the cold boot power up sequence. CSC[2:0] - Current Sense Configuration bits are output signals for ISENSE gain setting. This value is latched on the rising edge of VTTPWRGOOD. V O V and V provide an isolated, low impedance connection to the TTD_SENSE TTD_SENSE SS_SENSE_VTT processor power and ground. They can used to sense or measure power near the V O SS_SENSE_VTT silicon. VTTPWRGOOD I The processor requires this input signal to be a clean indication that the VTT power supply is stable and within their specifications. 'Clean' implies that the signal will remain low (capable of sinking leakage current), without glitches, from the time that the power supplies are turned on until they come within specification. The signal must then transition monotonically to a high state. to determine that the VTT voltage is stable and within specification. Note it is not valid for VTTPWRGOOD to be deasserted while VCCPWRGOOD is asserted. V The processor ground. SS Notes: 1. DDR{0/1/2} refers to DDR3 Channel 0, DDR3 Channel 1, and DDR3 Channel 2. 2. VID[7:0] is an Input only during Power On Configuration. It is an Output signal during normal operation. § ® ® 88 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6 Thermal Specifications 6.1 Package Thermal Specifications ® ® The Intel Xeon processor 5500 series requires a thermal solution to maintain temperatures within operating limits. Any attempt to operate the processor outside these limits may result in permanent damage to the processor and potentially other components within the system. Maintaining the proper thermal environment is key to reliable, long-term system operation. A complete solution includes both component and system level thermal management features. Component level thermal solutions can include active or passive heatsinks attached to the processor integrated heat spreader (IHS). Typical system level thermal solutions may consist of system fans combined with ducting and venting. This section provides data necessary for developing a complete thermal solution. For more information on designing a component level thermal solution, refer to the Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guide. Note: The boxed processor will ship with a component thermal solution. Refer to Section 8 for details on the boxed processor. 6.1.1 Thermal Specifications To allow optimal operation and long-term reliability of Intel processor-based systems, the processor must remain within the minimum and maximum case temperature (T ) specifications as defined by the applicable thermal profile. See Table 6-2 and CASE ® ® Figure 6-1 for Intel Xeon Processor W5580 (130W TDP); Table 6-4 and Table 6-5, and Figure 6-2 for Intel Xeon processor 5500 series Advanced SKU (95W TDP); Table 6-7 and Figure 6-3 for Intel Xeon processor 5500 series Standard/Basic SKUs (80W TDP); Table 6-9 and Figure 6-4 for Intel Xeon processor 5500 series Low Power ® ® Xeon Processor L5518 (60W SKU (60W TDP); Table 6-11 and Figure 6-5 for Intel ® ® TDP) supporting NEBS thermals; Table 6-13 and Figure 6-6 for Intel Xeon Processor L5508 (38W TDP) supporting NEBS thermals. Thermal solutions not designed to provide this level of thermal capability may affect the long-term reliability of the processor and system. For more details on thermal solution design, please refer to this processor’s TMDG. The Intel Xeon processor 5500 series implement a methodology for managing processor temperatures which is intended to support acoustic noise reduction through fan speed control and to assure processor reliability. Selection of the appropriate fan speed is based on the relative temperature data reported by the processor’s Platform Environment Control Interface (PECI) as described in Section 6.3. If PECI is less than TCONTROL, then the case temperature is permitted to exceed the Thermal Profile, but PECI must remain at or below TCONTROL. If PECI >= TCONTROL, then the case temperature must meet the Thermal Profile. The temperature reported over PECI is always a negative value and represents a delta below the onset of thermal control circuit (TCC) activation, as indicated by PROCHOT# (see Section 6.2, Processor Thermal Features). Systems that implement fan speed control must be designed to use this data. Systems that do not alter the fan speed only need to guarantee the case temperature meets the thermal profile specifications. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 89 Thermal Specifications The Intel Xeon Processor W5580 (see Figure 6-1; Table 6-2) supports a single Thermal Profile. For this processor, it is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most power-intensive applications. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide for details on system thermal solution design, thermal profiles and environmental considerations. The Intel Xeon processor 5500 series Advanced SKU supports two thermal profiles, either of which can be implemented. Both ensure adherence to Intel reliability requirements. Thermal Profile A (see Figure 6-2; Table 6-4) is representative of a volumetrically unconstrained thermal solution (that is, industry enabled 2U heatsink). In this scenario, it is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most power intensive applications. Thermal Profile B (see Figure 6-2; Table 6-5) is indicative of a constrained thermal environment (that is, 1U form factor). Because of the reduced cooling capability represented by this thermal solution, the probability of TCC activation and performance loss is increased. Additionally, utilization of a thermal solution that does not meet Thermal Profile B will violate the thermal specifications and may result in permanent damage to the processor. Refer to this processor’s TMDG for details on system thermal solution design, thermal profiles and environmental considerations. The upper point of the thermal profile consists of the Thermal Design Power (TDP) and value. It should be noted that the upper point associated with the the associated T CASE Intel Xeon processor 5500 series Advanced SKU Thermal Profile B (x = TDP and y=T @ TDP) represents a thermal solution design point. In actuality the CASE_MAX_B processor case temperature will not reach this value due to TCC activation (see Figure 6-2 for Intel Xeon processor 5500 series Advanced SKU). The Intel Xeon processor 5500 series Standard/Basic SKUs (see Figure 6-3; Table 6-7) support a single Thermal Profile. For this processor, it is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most power-intensive applications. Refer to this processor’s TMDG for details on system thermal solution design, thermal profiles and environmental considerations. The Intel Xeon processor 5500 series Low Power SKU (see Figure 6-4; Table 6-9) supports a single Thermal Profile. For this processor, it is expected that the Thermal Control Circuit (TCC) would only be activated for very brief periods of time when running the most power-intensive applications. Refer to this processor’s TMDG for details on system thermal solution design, thermal profiles and environmental considerations. The Intel Xeon Processor L5518 and Intel Xeon Processor L5508 both support Thermal Profiles with nominal and short-term conditions designed to meet NEBS level 3 compliance (see Figure 6-5 and Figure 6-6 respectively). For these SKU’s operation at either the nominal or short-term thermal profiles should result in virtually no TCC activation. Analysis indicates that real applications are unlikely to cause the processor to consume maximum power dissipation for sustained time periods. Intel recommends that complete thermal solution designs target the Thermal Design Power (TDP), instead of the maximum processor power consumption. The Adaptive Thermal Monitor feature is intended to help protect the processor in the event that an application exceeds the TDP recommendation for a sustained time period. For more details on this feature, refer to Section 6.2. To ensure maximum flexibility for future requirements, systems should be ® ® 90 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications designed to the Flexible Motherboard (FMB) guidelines, even if a processor with lower power dissipation is currently planned. The Adaptive Thermal Monitor feature must be enabled for the processor to remain within its specifications. Table 6-1. Intel® Xeon® Processor W5580 Thermal Specifications Thermal Design Minimum Maximum Core Power TCASE TCASE Notes Frequency (W) (°C) (°C) Launch to FMB 130 5 See Figure 6-2; Table 6-4 1, 2, 3, 4, 5 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified ICC. Please refer to the loadline specifications in Section 2.6. 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon processor 5500 series may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Figure 6-1. Intel® Xeon® Processor W5580 Thermal Profile Notes: 1. Intel Xeon Processor W5580 Thermal Profile is representative of a volumetrically unconstrained platform. Please refer to Table 6-2 for discrete points that constitute the thermal profile. 2. Implementation of Intel Xeon Processor W5580 Thermal Profile should result in virtually no TCC activation. 3. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide for system and environmental implementation details. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 91 Thermal Specifications Table 6-2. Intel Xeon Processor W5580 Thermal Profile Power (W) T (°C) CASE_MAX 0 43.5 5 44.4 10 45.3 15 46.2 20 47.1 25 48.0 30 48.9 35.6 49.9 40 50.7 45 51.6 50 52.6 55 53.5 60 54.4 65 55.3 70 56.2 75 57.1 80 58.0 85 58.9 90 59.8 95 60.7 100 61.6 105 62.5 110 63.4 115 64.3 120 65.2 125 66.1 130 67.0 Table 6-3. Intel Xeon Processor 5500 Series Advanced SKU Thermal Specifications Thermal Design Minimum Maximum Core Power TCASE TCASE Notes Frequency (W) (°C) (°C) Launch to FMB 95 5 See Figure 6-2; Table 6-4 1, 2, 3, 4, 5 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified ICC. Please refer to the loadline specifications in Section 2.6. 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon processor 5500 series may be shipped under multiple VIDs for each frequency. 5. FMB or Flexible Motherboard guidelines provide a design target for meeting all planned processor frequency requirements. ® ® 92 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Figure 6-2. Intel® Xeon® Processor 5500 Series Advanced SKU Thermal Profile 85 80 TCASE_M AX is a therm al solution design point. In actuality, units will not significantly exceed TCASE_M AX_A due to TCC activation. 75 70 Thermal Profile B Y = 0.244*p + 57.8 65 60 55 50 45 40 0 5 1 0 15 20 2 5 30 3 5 40 4 5 5 0 55 6 0 65 7 0 75 8 0 85 90 9 5 Power [W ] Notes: 1. Intel Xeon processor 5500 series Advanced SKU Thermal Profile A is representative of a volumetrically unconstrained platform. Please refer to Table 6-4 for discrete points that constitute thermal profile A. 2. Implementation of Intel Xeon processor 5500 series Advanced SKU Thermal Profile A should result in virtually no TCC activation. Furthermore, utilization of thermal solutions that do not meet Profile A will result in increased probability of TCC activation and may incur measurable performance loss. 3. Intel Xeon processor 5500 series Advanced SKU Thermal Profile B is representative of a volumetrically constrained platform. Please refer to Table 6-5 for discrete points that constitute thermal profile B. 4. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide for system and environmental implementation details. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 93 Temperature [C] Thermal Specifications Table 6-4. Intel Xeon Processor 5500 Series Advanced SKU Thermal Profile A Power (W) T (°C) CASE_MAX 0 57.8 5 58.7 10 59.6 15 60.5 20 61.4 25 62.3 30 63.2 35.6 64.2 40 65.0 45 65.9 50 66.9 55 67.8 60 68.7 65 69.6 70 70.5 75 71.4 80 72.3 85 73.2 90 74.1 95 75.0 Table 6-5. Intel Xeon Processor 5500 Series Advanced SKU Thermal Profile B Power (W) T (°C) CASE_MAX 0 57.8 5 59.0 10 60.2 15 61.5 20 62.7 25 63.9 30 65.1 35 66.3 40 67.6 45 68.8 50 70.0 55 71.2 60 72.4 65 73.7 70 74.9 75 76.1 80 77.3 85 78.5 90 79.8 95 81.0 ® ® 94 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Table 6-6. Intel Xeon Processor 5500 Series Standard/Basic SKUs Thermal Specifications Thermal Minimum Maximum Core Design Power TCASE TCASE Notes Frequency (W) (°C) (°C) Launch to FMB 80 5 See Figure 6-3; 1, 2, 3, 4, 5 Table 6-7; Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon processor 5500 series may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Figure 6-3. Intel Xeon Processor 5500 Series Standard/Basic SKUs Thermal Profile Notes: 1. Intel Xeon processor 5500 series Standard/Basic SKUs processor Thermal Profile is representative of a volumetrically constrained platform. Please refer to Table 6-7 for discrete points that constitute the thermal profile. 2. Implementation of Intel Xeon processor 5500 series Standard/Basic SKUs Thermal Profile should result in virtually no TCC activation. 3. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide for system and environmental implementation details. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 95 Thermal Specifications Table 6-7. Intel Xeon Processor 5500 Series Standard/Basic SKUs Thermal Profile Power (W) T (°C) CASE_MAX 0 51.8 5 53.3 10 54.8 15 56.3 20 57.9 25 59.4 30 60.9 35 62.4 40 63.9 45 65.4 50 67.0 55 68.5 60 70.0 65 71.5 70 73.0 75 74.5 80 76.0 Table 6-8. Intel Xeon Processor 5500 Series Low Power SKU Thermal Specifications Core Thermal Design Power Minimum TCASE Maximum TCASE Notes Frequency (W) (°C) (°C) Launch to FMB 60 5 See Figure 6-4; 1, 2, 3, 4, 5 Table 6-9 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon processor 5500 series Low Power SKU may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. ® ® 96 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Figure 6-4. Intel Xeon Processor 5500 Series Low Power SKU Thermal Profile Notes: 1. Intel Xeon processor 5500 series Low Power SKU Thermal Profile is representative of a volumetrically constrained platform. Please refer to Table 6-9 for discrete points that constitute the thermal profile. 2. Implementation of Intel Xeon processor 5500 series Low Power SKU Thermal Profile should result in virtually no TCC activation. Furthermore, utilization of thermal solutions that do not meet Intel Xeon processor 5500 series Low Power SKU Thermal Profile will result in increased probability of TCC activation and may incur measurable performance loss. 3. Refer to the Intel® Xeon® Processor 5500 Series Thermal / Mechanical Design Guide for system and environmental implementation details. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 97 Thermal Specifications Table 6-9. Intel Xeon Processor 5500 Series Low Power SKU Thermal Profile Power (W) T (°C) CASE_MAX 0 51.9 5 53.4 10 54.9 15 56.4 20 57.9 25 59.5 30 61.0 35 62.5 40 64.0 45 65.5 50 67.0 55 68.5 60 70.0 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon processor 5500 series may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Table 6-10. Intel Xeon Processor L5518 Thermal Specifications Core Thermal Design Power Minimum TCASE Maximum TCASE Notes Frequency (W) (°C) (°C) Launch to FMB 60 5 See Figure 6-5; 1, 2, 3, 4, 5 Table 6-11 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon Processor L5518 may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements ® ® 98 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Figure 6-5. Intel Xeon Processor L5518 Thermal Profile Notes: 1. Intel Xeon Processor L5518 Thermal Profile is representative of a volumetrically constrained platform. Please refer to Table 6-11 for discrete points that constitute the thermal profile. 2. Implementation of Intel Xeon Processor L5518 nominal and short-term thermal profiles should result in virtually no TCC activation. Furthermore, utilization of thermal solutions that do not meet this Thermal Profile will result in increased probability of TCC activation and may incur measurable performance loss. 3. The Nominal Thermal Profile must be used for all normal operating conditions, or for products that do not require NEBS Level 3 compliance. 4. The Short-Term Thermal Profile may only be used for short-term excursions to higher ambient operating temperatures, not to exceed 96 hours per instance, 360 hours per year, and a maximum of 15 instances per year, as compliant with NEBS Level 3. Operation at the Short-Term Thermal Profile for durations exceeding 360 hours per year violate the processor thermal specifications and may result in permanent damage to the processor. 5. Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide for system and environmental implementation details. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 99 Thermal Specifications Table 6-11. Intel Xeon Processor L5518 Thermal Profile Power (W) Nominal T (°C) Short-term T (°C) CASE_MAX CASE_MAX 0 51.9 66.9 5 53.4 68.4 10 54.9 69.9 15 56.4 71.4 20 57.9 72.9 25 59.5 74.5 30 61.0 76.0 35 62.5 77.5 40 64.0 79.0 45 65.5 80.5 50 67.0 82.0 55 68.5 83.5 60 70.0 85.0 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon Processor L5518 may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. Table 6-12. Intel Xeon Processor L5508 Thermal Specifications Core Thermal Design Power Minimum TCASE Maximum TCASE Notes Frequency (W) (°C) (°C) Launch to FMB 38 5 See Figure 6-6; 1, 2, 3, 4, 5, 6 Table 6-13 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon Processor L5508 may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. ® ® 100 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Figure 6-6. Intel Xeon Processor L5508 Thermal Profile Notes: 1. Intel Xeon Processor L5508 Thermal Profile is representative of a volumetrically constrained platform. Please refer to Table 6-13 for discrete points that constitute the thermal profile. 2. Implementation of Intel Xeon Processor L5508 nominal and short-term thermal profiles should result in virtually no TCC activation. Furthermore, utilization of thermal solutions that do not meet this Thermal Profile will result in increased probability of TCC activation and may incur measurable performance loss. 3. The Nominal Thermal Profile must be used for all normal operating conditions, or for products that do not require NEBS Level 3 compliance. 4. The Short-Term Thermal Profile may only be used for short-term excursions to higher ambient operating temperatures, not to exceed 96 hours per instance, 360 hours per year, and a maximum of 15 instances per year, as compliant with NEBS Level 3. Operation at the Short-Term Thermal Profile for durations exceeding 360 hours per year violate the processor thermal specifications and may result in permanent damage to the processor. 5. Refer to the Intel® Xeon® Processor 5500 Series Thermal / Mechanical Design Guide for system and environmental implementation details. Table 6-13. Intel Xeon Processor L5508 Thermal Profile Power (W) Nominal T (°C) Short-Term T (°C) CASE_MAX CASE_MAX 0 50.0 65.0 5 52.7 67.7 10 55.3 70.3 15 58.0 73.0 20 60.6 75.6 25 63.3 78.3 30 66.0 81.0 35 68.6 83.6 38 70.2 85.2 Notes: 1. These values are specified at V for all processor frequencies. Systems must be designed to ensure CC_MAX the processor is not to be subjected to any static V and I combination wherein V exceeds V at CC CC CC CC_MAX specified I . Please refer to the loadline specifications in Section 2.6. CC ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 101 Thermal Specifications 2. Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum T . CASE 3. These specifications are based on initial silicon characterization. These specifications may be further updated as more characterization data becomes available. 4. Power specifications are defined at all VIDs found in Table 2-2. The Intel Xeon Processor L5508 may be shipped under multiple VIDs for each frequency. 5. FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements. 6.1.2 Thermal Metrology The minimum and maximum case temperatures (T ) are specified in Table 6-6, CASE through Table 6-13 and are measured at the geometric top center of the processor integrated heat spreader (IHS). Figure 6-7 illustrates the location where T CASE temperature measurements should be made. For detailed guidelines on temperature measurement methodology, refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide. Figure 6-7. Case Temperature (T ) Measurement Location CASE Notes: 1. Figure is not to scale and is for reference only. 2. B1: Max = 45.07 mm, Min = 44.93 mm. 3. B2: Max = 42.57 mm, Min = 42.43 mm. 4. C1: Max = 39.1 mm, Min = 38.9 mm. 5. C2: Max = 36.6 mm, Min = 36.4 mm. 6. C3: Max = 2.3 mm, Min = 2.2 mm 7. C4: Max = 2.3 mm, Min = 2.2 mm. ® ® 102 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.2 Processor Thermal Features 6.2.1 Processor Temperature A new feature in the Intel Xeon processor 5500 series is a software readable field in the IA32_TEMPERATURE_TARGET register that contains the minimum temperature at which the TCC will be activated and PROCHOT# will be asserted. The TCC activation temperature is calibrated on a part-by-part basis and normal factory variation may result in the actual TCC activation temperature being higher than the value listed in the register. TCC activation temperatures may change based on processor stepping, frequency or manufacturing efficiencies. Note: There is no specified correlation between DTS temperatures and processor case temperatures; therefore it is not possible to use this feature to ensure the processor case temperature meets the Thermal Profile specifications. 6.2.2 Adaptive Thermal Monitor The Adaptive Thermal Monitor feature provides an enhanced method for controlling the processor temperature when the processor silicon reaches its maximum operating temperature. Adaptive Thermal Monitor uses Thermal Control Circuit (TCC) activation to reduce processor power via a combination of methods. The first method (Frequency/VID control) involves the processor adjusting its operating frequency (via the core ratio multiplier) and input voltage (via the VID signals). This combination of reduced frequency and VID results in a reduction to the processor power consumption. The second method (clock modulation) reduces power consumption by modulating (starting and stopping) the internal processor core clocks. The processor intelligently selects the appropriate TCC method to use on a dynamic basis. BIOS is not required to select a specific method (as with previous-generation processors supporting TM1 or TM2). The Adaptive Thermal Monitor feature must be enabled for the processor to be operating within specifications. The temperature at which Adaptive Thermal Monitor activates the Thermal Control Circuit is not user configurable and is not software visible. Snooping and interrupt processing are performed in the normal manner while the TCC is active. With a properly designed and characterized thermal solution, it is anticipated that the TCC would only be activated for very short periods of time when running the most power intensive applications. The processor performance impact due to these brief periods of TCC activation is expected to be so minor that it would be immeasurable. An under-designed thermal solution that is not able to prevent excessive activation of the TCC in the anticipated ambient environment may cause a noticeable performance loss, and in some cases may result in a T that exceeds the specified maximum temperature C which may affect the long-term reliability of the processor. In addition, a thermal solution that is significantly under-designed may not be capable of cooling the processor even when the TCC is active continuously. Refer to the appropriate Thermal/Mechanical Design Guide for information on designing a compliant thermal solution. The duty cycle for the TCC, when activated by the Thermal Monitor, is factory configured and cannot be modified. The Thermal Monitor does not require any additional hardware, software drivers, or interrupt handling routines. The following sections provide more details on the different TCC mechanisms used by Intel Xeon processor 5500 series. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 103 Thermal Specifications 6.2.2.1 Frequency/VID Control The processor uses Frequency/VID control whereby TCC activation causes the processor to adjust its operating frequency (via the core ratio multiplier) and input voltage (via the VID signals). This combination of reduced frequency and VID results in a reduction to the processor power consumption. This method includes multiple operating points, each consisting of a specific operating frequency and voltage. The first operating point represents the normal operating condition for the processor. The remaining points consist of both lower operating frequencies and voltages. When the TCC is activated, the processor automatically transitions to the new operating frequency. This transition occurs very rapidly (on the order of 2 µs). Once the new operating frequency is engaged, the processor will transition to the new core operating voltage by issuing a new VID code to the voltage regulator. The voltage regulator must support dynamic VID steps to support this method. During the voltage change, it will be necessary to transition through multiple VID codes to reach the target operating voltage. Each step will be one VID table entry (see Table 2-2). The processor continues to execute instructions during the voltage transition. Operation at the lower voltages reduces the power consumption of the processor. A small amount of hysteresis has been included to prevent rapid active/inactive transitions of the TCC when the processor temperature is near its maximum operating temperature. Once the temperature has dropped below the maximum operating temperature, and the hysteresis timer has expired, the operating frequency and voltage transition back to the normal system operating point via the intermediate VID/frequency points. Transition of the VID code will occur first, to insure proper operation once the processor reaches its normal operating frequency. Refer to Figure 6-8 for an illustration of this ordering. Figure 6-8. Frequency and Voltage Ordering T Te em mp per eratur ature e ff MAX MAX ff 1 1 ff 2 2 Fr Frequ eque ency ncy VIDf VIDf MAX MAX VI VID Dff 1 1 VI VID Dff 2 2 VI VID D PRO PROC CH HO OT T# # Ti Time me ® ® 104 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.2.2.2 Clock Modulation Clock modulation is performed by alternately turning the clocks off and on at a duty cycle specific to the processor (factory configured to 37.5% on and 62.5% off). The period of the duty cycle is configured to 32 microseconds when the TCC is active. Cycle times are independent of processor frequency. A small amount of hysteresis has been included to prevent rapid active/inactive transitions of the TCC when the processor temperature is near its maximum operating temperature. Once the temperature has dropped below the maximum operating temperature, and the hysteresis timer has expired, the TCC goes inactive and clock modulation ceases. Clock modulation is automatically engaged as part of the TCC activation when the Frequency/VID targets are at their minimum settings. It may also be initiated by software at a configurable duty cycle. 6.2.3 On-Demand Mode The processor provides an auxiliary mechanism that allows system software to force the processor to reduce its power consumption. This mechanism is referred to as “On- Demand” mode and is distinct from the Adaptive Thermal Monitor feature. On-Demand mode is intended as a means to reduce system level power consumption. Systems utilizing the Intel Xeon processor 5500 series must not rely on software usage of this mechanism to limit the processor temperature. If bit 4 of the IA32_CLOCK_MODULATION MSR is set to a ‘1’, the processor will immediately reduce its power consumption via modulation (starting and stopping) of the internal core clock, independent of the processor temperature. When using On-Demand mode, the duty cycle of the clock modulation is programmable via bits 3:1 of the same IA32_CLOCK_MODULATION MSR. In On-Demand mode, the duty cycle can be programmed from 12.5% on/ 87.5% off to 87.5% on/12.5% off in 12.5% increments. On-Demand mode may be used in conjunction with the Adaptive Thermal Monitor; however, if the system tries to enable On-Demand mode at the same time the TCC is engaged, the factory configured duty cycle of the TCC will override the duty cycle selected by the On-Demand mode. 6.2.4 PROCHOT# Signal An external signal, PROCHOT# (processor hot), is asserted when the processor core temperature has reached its maximum operating temperature. If Adaptive Thermal Monitor is enabled (note it must be enabled for the processor to be operating within specification), the TCC will be active when PROCHOT# is asserted. The processor can be configured to generate an interrupt upon the assertion or de-assertion of PROCHOT#. The PROCHOT# signal is bi-directional in that it can either signal when the processor (any core) has reached its maximum operating temperature or be driven from an external source to activate the TCC. The ability to activate the TCC via PROCHOT# can provide a means for thermal protection of system components. As an output, PROCHOT# will go active when the processor temperature monitoring sensor detects that one or more cores has reached its maximum safe operating temperature. This indicates that the processor Thermal Control Circuit (TCC) has been activated, if enabled. As an input, assertion of PROCHOT# by the system will activate the TCC, if enabled, for all cores. TCC activation due to PROCHOT# assertion by the system will result in the processor immediately transitioning to the minimum frequency and corresponding voltage (using Freq/VID control). Clock modulation is not activated in this case. The TCC will remain active until the system de-asserts PROCHOT#. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 105 Thermal Specifications PROCHOT# can allow VR thermal designs to target maximum sustained current instead of maximum current. Systems should still provide proper cooling for the VR, and rely on PROCHOT# only as a backup in case of system cooling failure. The system thermal design should allow the power delivery circuitry to operate within its temperature specification even while the processor is operating at its Thermal Design Power. With a properly designed and characterized thermal solution, it is anticipated that PROCHOT# will only be asserted for very short periods of time when running the most power intensive applications. An under-designed thermal solution that is not able to prevent excessive assertion of PROCHOT# in the anticipated ambient environment may cause a noticeable performance loss. Refer to the appropriate platform design guide and for details on implementing the bi-directional PROCHOT# feature. 6.2.5 THERMTRIP# Signal Regardless of whether Adaptive Thermal Monitor is enabled, in the event of a catastrophic cooling failure, the processor will automatically shut down when the silicon has reached an elevated temperature (refer to the THERMTRIP# definition in Table 5-1). THERMTRIP# activation is independent of processor activity and does not generate any Intel® QuickPath Interconnect transactions. The temperature at which THERMTRIP# asserts is not user configurable and is not software visible. 6.3 Platform Environment Control Interface (PECI) The Platform Environment Control Interface (PECI) uses a single wire for self-clocking and data transfer. The bus requires no additional control lines. The physical layer is a self-clocked one-wire bus that begins each bit with a driven, rising edge from an idle level near zero volts. The duration of the signal driven high depends on whether the bit value is a logic ‘0’ or logic ‘1’. PECI also includes variable data transfer rate established with every message. In this way, it is highly flexible even though underlying logic is simple. The interface design was optimized for interfacing to Intel processor and chipset components in both single processor and multiple processor environments. The single wire interface provides low board routing overhead for the multiple load connections in the congested routing area near the processor and chipset components. Bus speed, error checking, and low protocol overhead provides adequate link bandwidth and reliability to transfer critical device operating conditions and configuration information. The PECI bus offers: • A wide speed range from 2 Kbps to 2 Mbps • CRC check byte used to efficiently and atomically confirm accurate data delivery • Synchronization at the beginning of every message minimizes device timing accuracy requirements Note that the PECI commands described in this document apply to the Intel Xeon processor 5500 series only. Refer to Table 6-14 for the list of PECI commands supported by the Intel Xeon processor 5500 series PECI client. ® ® 106 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Table 6-14. Summary of Processor-specific PECI Commands Supported on Intel Xeon Processor Command 5500 Series CPU Ping() Yes GetDIB() Yes GetTemp() Yes PCIConfigRd() Yes PCIConfigWr() Yes 1 MbxSend() Yes 1 MbxGet() Yes Note: 1. Refer to Table 6-19 for a summary of mailbox commands supported by the Intel Xeon processor 5500 series CPU. 6.3.1 PECI Client Capabilities The Intel Xeon processor 5500 series PECI client is designed to support the following sideband functions: • Processor and DRAM thermal management • Platform manageability functions including thermal, power and electrical error monitoring ® • Processor interface tuning and diagnostics capabilities (Intel Interconnect BIST ® [Intel IBIST]). 6.3.1.1 Thermal Management Processor fan speed control is managed by comparing PECI thermal readings against the processor-specific fan speed control reference point, or T . Both T CONTROL CONTROL and PECI thermal readings are accessible via the processor PECI client. These variables are referenced to a common temperature, the TCC activation point, and are both defined as negative offsets from that reference. Algorithms for fan speed management using PECI thermal readings and the T reference are documented in CONTROL Section 6.3.2.6. PECI-based access to DRAM thermal readings and throttling control coefficients provide a means for Board Management Controllers (BMCs) or other platform management devices to feed hints into on-die memory controller throttling algorithms. These control coefficients are accessible using PCI configuration space writes via PECI. The PECI- based configuration write functionality is defined in Section 6.3.2.5, and the DRAM throttling coefficient control functions are documented in the Intel® Xeon® Processor 5500 Series Datasheet, Volume 2. 6.3.1.2 Platform Manageability PECI allows full read access to error and status monitoring registers within the processor’s PCI configuration space. It also provides insight into thermal monitoring functions such as TCC activation timers and thermal error logs. The exact list of RAS-related registers in the PCI configuration space can be found in the Intel® Xeon® Processor 5500 Series Datasheet, Volume 2. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 107 Thermal Specifications 6.3.1.3 Processor Interface Tuning and Diagnostics Intel Xeon processor 5500 series Intel IBIST allows for in-field diagnostic capabilities in Intel QuickPath Interconnect and memory controller interfaces. PECI provides a port to execute these diagnostics via its PCI Configuration read and write capabilities. 6.3.2 Client Command Suite 6.3.2.1 Ping() Ping() is a required message for all PECI devices. This message is used to enumerate devices or determine if a device has been removed, been powered-off, etc. A Ping() sent to a device address always returns a non-zero Write FCS if the device at the targeted address is able to respond. 6.3.2.1.1 Command Format The Ping() format is as follows: Write Length: 0 Read Length: 0 Figure 6-9. Ping() Byte # 0 1 2 3 Write Length Read Length Client Address FCS Byte 0x00 0x00 Definition An example Ping() command to PECI device address 0x30 is shown below. Figure 6-10. Ping() Example Byte # 0 1 2 3 Byte 0x30 0x00 0x00 0xe1 Definition 6.3.2.2 GetDIB() The processor PECI client implementation of GetDIB() includes an 8-byte response and provides information regarding client revision number and the number of supported domains. All processor PECI clients support the GetDIB() command. 6.3.2.2.1 Command Format The GetDIB() format is as follows: Write Length: 1 Read Length: 8 Command: 0xf7 ® ® 108 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Figure 6-11. GetDIB() Byte # 0 1 2 3 4 Write Length Read Length Cmd Code Client Address FCS Byte 0x01 0x08 0xf7 Definition 5 6 7 8 9 Revision Device Info Reserved Reserved Reserved Number 10 11 12 13 Reserved Reserved Reserved FCS 6.3.2.2.2 Device Info The Device Info byte gives details regarding the PECI client configuration. At a minimum, all clients supporting GetDIB will return the number of domains inside the package via this field. With any client, at least one domain (Domain 0) must exist. Therefore, the Number of Domains reported is defined as the number of domains in addition to Domain 0. For example, if the number 0b1 is returned, that would indicate that the PECI client supports two domains. Figure 6-12. Device Info Field Definition 76 543 21 0 Reserved # of Domains Reserved 6.3.2.2.3 Revision Number All clients that support the GetDIB command also support Revision Number reporting. The revision number may be used by a host or originator to manage different command suites or response codes from the client. Revision Number is always reported in the second byte of the GetDIB() response. The Revision Number always maps to the revision number of this document. Figure 6-13. Revision Number Definition 7 4 3 0 Major Revision# Minor Revision# For a client that is designed to meet the specification, the Revision Number it returns will be ‘0010 0000b’. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 109 Thermal Specifications 6.3.2.3 GetTemp() The GetTemp() command is used to retrieve the temperature from a target PECI address. The temperature is used by the external thermal management system to regulate the temperature on the die. The data is returned as a negative value representing the number of degrees centigrade below the Thermal Control Circuit Activation temperature of the PECI device. Note that a value of zero represents the temperature at which the Thermal Control Circuit activates. The actual value that the thermal management system uses as a control set point (Tcontrol) is also defined as a negative number below the Thermal Control Circuit Activation temperature. TCONTROL may be extracted from the processor by issuing a PECI Mailbox MbxGet() (see Section 6.3.2.8), or using a RDMSR instruction. Please refer to Section 6.3.6 for details regarding temperature data formatting. 6.3.2.3.1 Command Format The GetTemp() format is as follows: Write Length: 1 Read Length: 2 Command: 0x01 Multi-Domain Support: Yes (see Table 6-26) Description: Returns the current temperature for addressed processor PECI client. Figure 6-14. GetTemp() Byte # 0 1 2 3 Write Length Read Length Cmd Code Client Address Byte 0x01 0x02 0x01 Definition 4 5 6 7 FCS Temp[7:0] Temp[15:8] FCS Example bus transaction for a thermal sensor device located at address 0x30 returning a value of negative 10°C: Figure 6-15. GetTemp() Example Byte # 0 1 2 3 Byte 0x30 0x01 0x02 0x01 Definition 4 5 6 7 0xef 0x80 0xfd 0x4b ® ® 110 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.3.2.3.2 Supported Responses The typical client response is a passing FCS and good thermal data. Under some conditions, the client’s response will indicate a failure. Table 6-15. GetTemp() Response Definition Response Meaning General Sensor Error (GSE) Thermal scan did not complete in time. Retry is appropriate. 0x0000 Processor is running at its maximum temperature or is currently being reset. All other data Valid temperature reading, reported as a negative offset from the TCC activation temperature. 6.3.2.4 PCIConfigRd() The PCIConfigRd() command gives sideband read access to the entire PCI configuration space maintained in the processor. This capability does not include support for route- through to downstream devices or sibling processors. The exact listing of supported devices, functions, and registers can be found in the Intel® Xeon® Processor 5500 Series Datasheet, Volume 2. PECI originators may conduct a device/function/register enumeration sweep of this space by issuing reads in the same manner that BIOS would. A response of all 1’s indicates that the device/function/register is unimplemented. PCI configuration addresses are constructed as shown in the following diagram. Under normal in-band procedures, the Bus number (including any reserved bits) would be used to direct a read or write to the proper device. Since there is a one-to-one mapping between any given client address and the bus number, any request made with a bad Bus number is ignored and the client will respond with a ‘pass’ completion code but all 0’s in the data. The only legal bus number is 0x00. The client will return all 1’s in the data response and ‘pass’ for the completion code for all of the following conditions: • Unimplemented Device • Unimplemented Function • Unimplemented Register Figure 6-16. PCI Configuration Address 31 28 27 20 19 15 14 12 11 0 Reserved Bus Device Function Register PCI configuration reads may be issued in byte, word, or dword granularities. 6.3.2.4.1 Command Format The PCIConfigRd() format is as follows: Write Length: 5 Read Length: 2 (byte data), 3 (word data), 5 (dword data) Command: 0xc1 Multi-Domain Support: Yes (see Table 6-26) ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 111 Thermal Specifications Description: Returns the data maintained in the PCI configuration space at the PCI configuration address sent. The Read Length dictates the desired data return size. This command supports byte, word, and dword responses as well as a completion code. All command responses are prepended with a completion code that includes additional pass/fail status information. Refer to Section 6.3.4.2 for details regarding completion codes. Figure 6-17. PCIConfigRd() Byte # 0 1 2 3 Write Length Read Length Cmd Code Client Address Byte 0x05 {0x02,0x03,0x05} 0xc1 Definition 4 5 6 7 8 LSB PCI Configuration Address MSB FCS 9 10 8+RL 9+RL Completion Data 0 ... Data N FCS Code Note that the 4-byte PCI configuration address defined above is sent in standard PECI ordering with LSB first and MSB last. 6.3.2.4.2 Supported Responses The typical client response is a passing FCS, a passing Completion Code (CC) and valid Data. Under some conditions, the client’s response will indicate a failure. Table 6-16. PCIConfigRd() Response Definition Response Meaning Abort FCS Illegal command formatting (mismatched RL/WL/Command Code) CC: 0x40 Command passed, data is valid CC: 0x80 Error causing a response timeout. Either due to a rare, internal timing condition or a processor RESET or processor S1 state. Retry is appropriate outside of the RESET or S1 states. 6.3.2.5 PCIConfigWr() The PCIConfigWr() command gives sideband write access to the PCI configuration space maintained in the processor. The exact listing of supported devices, functions is defined below in Table 6-17. PECI originators may conduct a device/function/register enumeration sweep of this space by issuing reads in the same manner that BIOS would. ® ® 112 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Table 6-17. PCIConfigWr() Device/Function Support Writable Description Device Function 21 Intel QuickPath Interconnect Link 0 Intel IBIST 25 Intel QuickPath Interconnect Link 1 Intel IBIST 1 3 4 Memory Controller Intel IBIST 4 3 Memory Controller Channel 0 Thermal Control / Status 5 3 Memory Controller Channel 1 Thermal Control / Status 6 3 Memory Controller Channel 2 Thermal Control / Status Notes: 1. Currently not available for access through the PECI PCIConfigWr() command. PCI configuration addresses are constructed as shown in Figure 6-16, and this command is subject to the same address configuration rules as defined in Section 6.3.2.4. PCI configuration reads may be issued in byte, word, or dword granularities. Because a PCIConfigWr() results in an update to potentially critical registers inside the processor, it includes an Assured Write FCS (AW FCS) byte as part of the write data payload. In the event that the AW FCS mismatches with the client-calculated FCS, the client will abort the write and will always respond with a bad Write FCS. 6.3.2.5.1 Command Format The PCIConfigWr() format is as follows: Write Length: 7 (byte), 8 (word), 10 (dword) Read Length: 1 Command: 0xc5 Multi-Domain Support: Yes (see Table 6-26) Description: Writes the data sent to the requested register address. Write Length dictates the desired write granularity. The command always returns a completion code indicating the pass/fail status information. Write commands issued to illegal Bus Numbers, or unimplemented Device / Function / Register addresses are ignored but return a passing completion code. Refer to Section 6.3.4.2 for details regarding completion codes. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 113 Thermal Specifications Figure 6-18. PCIConfigWr() Byte # 0 1 2 3 Write Length Read Length Cmd Code Client Address Byte {0x07,0x08,0x10} 0x01 0xc5 Definition 4 5 6 7 LSB PCI Configuration Address MSB 8 WL-1 LSB Data (1, 2 or 4 bytes) MSB WL WL+1 WL+2 WL+3 Completion AW FCS FCS FCS Code Note that the 4-byte PCI configuration address and data defined above are sent in standard PECI ordering with LSB first and MSB last. 6.3.2.5.2 Supported Responses The typical client response is a passing FCS, a passing Completion Code and valid Data. Under some conditions, the client’s response will indicate a failure. Table 6-18. PCIConfigWr() Response Definition Response Meaning Bad FCS Electrical error or AW FCS failure Abort FCS Illegal command formatting (mismatched RL/WL/Command Code) CC: 0x40 Command passed, data is valid CC: 0x80 Error causing a response timeout. Either due to a rare, internal timing condition or a processor RESET condition or processor S1 state. Retry is appropriate outside of the RESET or S1 states. 6.3.2.6 Mailbox The PECI mailbox (“Mbx”) is a generic interface to access a wide variety of internal processor states. A Mailbox request consists of sending a 1-byte request type and 4-byte data to the processor, followed by a 4-byte read of the response data. The following sections describe the Mailbox capabilities as well as the usage semantics for the MbxSend and MbxGet commands which are used to send and receive data. ® ® 114 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.3.2.6.1 Capabilities Table 6-19. Mailbox Command Summary Request MbxSend MbxGet Command Type Data Data Description Name Code (dword) (dword) (byte) Ping 0x00 0x00 0x00 Verify the operability / existence of the Mailbox. Thermal 0x01 Log bit clear Thermal Read the thermal status register and optionally clear any log bits. Status mask Status The thermal status has status and log bits indicating the state of Read/Clear Register processor TCC activation, external PROCHOT# assertion, and Critical Temperature threshold crossings. Counter 0x03 0x00 0x00 Snapshots all PECI-based counters Snapshot Counter Clear 0x04 0x00 0x00 Concurrently clear and restart all counters. Counter Read 0x05 Counter Counter Data Returns the counter number requested. Number 0: Total reference time 1: Total TCC Activation time counter Icc-TDC Read 0x06 0x00 Icc-TDC Returns the specified Icc-TDC of this part, in Amps. Thermal Config 0x07 0x00 Thermal Reads the thermal averaging constant. Data Read config data Thermal Config 0x08 Thermal 0x00 Writes the thermal averaging constant. Data Write Config Data Tcontrol Read 0x09 0x00 Tcontrol Reads the fan speed control reference temperature, Tcontrol, in PECI temperature format. Machine Check 0x0A Bank Register Data Read CPU Machine Check Banks. Read Number / Index T-state 0xB 0x00 ACPI T-state Reads the PECI ACPI T-state throttling control word. Throttling Control Word Control Read T-state 0xC ACPI T- 0x00 Writes the PECI ACPI T-state throttling control word. Throttling state Control Write Control Word Any MbxSend request with a request type not defined in Table 6-19 will result in a failing completion code. More detailed command definitions follow. 6.3.2.6.2 Ping The Mailbox interface may be checked by issuing a Mailbox ‘Ping’ command. If the command returns a passing completion code, it is functional. Under normal operating conditions, the Mailbox Ping command should always pass. 6.3.2.6.3 Thermal Status Read / Clear The Thermal Status Read provides information on package level thermal status. Data includes: • The status of TCC activation • Bidirectional PROCHOT# assertion •Critical Temperature ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 115 Thermal Specifications These status bits are a subset of the bits defined in the IA32_THERM_STATUS MSR on the processor, and more details on the meaning of these bits may be found in the 64 and IA-32 Architectures Software Developer’s Manual, Vol. 3B. Intel Both status and sticky log bits are managed in this status word. All sticky log bits are set upon a rising edge of the associated status bit, and the log bits are cleared only by Thermal Status reads or a processor reset. A read of the Thermal Status Word always includes a log bit clear mask that allows the host to clear any or all log bits that it is interested in tracking. A bit set to 0b0 in the log bit clear mask will result in clearing the associated log bit. If a mask bit is set to 0b0 and that bit is not a legal mask, a failing completion code will be returned. A bit set to 0b1 is ignored and results in no change to any sticky log bits. For example, to clear the TCC Activation Log bit and retain all other log bits, the Thermal Status Read should send a mask of 0xFFFFFFFD. Figure 6-19. Thermal Status Word 3 65 43 2 1 0 1 Reserved Critical Temperature Log Critical Temperature Status Bidirectional PROCHOT# Log Bidirectional PROCHOT# Status TCC Activation Log TCC Activation Status 6.3.2.6.4 Counter Snapshot / Read / Clear A reference time and ‘Thermally Constrained’ time are managed in the processor. These two counters are managed via the Mailbox. These counters are valuable for detecting thermal runaway conditions where the TCC activation duty cycle reaches excessive levels. The counters may be simultaneously snapshot, simultaneously cleared, or independently read. The simultaneous snapshot capability is provided in order to guarantee concurrent reads even with significant read latency over the PECI bus. Each counter is 32-bits wide. Table 6-20. Counter Definition Counter Counter Name Definition Number Total Time 0x00 Counts the total time the processor has been executing with a resolution of approximately 1ms. This counter wraps at 32 bits. Thermally Constrained Time 0x01 Counts the total time the processor has been operating at a lowered performance due to TCC activation. This timer includes the time required to ramp back up to the original P-state target after TCC activation expires. This timer does not include TCC activation time as a result of an external assertion of PROCHOT#. ® ® 116 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.3.2.6.5 Icc-TDC Read Icc-TDC is the Intel Xeon processor 5500 series TDC current draw specification. This data may be used to confirm matching Icc profiles of processors in DP configurations. It may also be used during the processor boot sequence to verify processor compatibility with motherboard Icc delivery capabilities. This command returns Icc-TDC in units of 1 Amp. 6.3.2.6.6 TCONTROL Read TCONTROL is used for fan speed control management. The TCONTROL limit may be read over PECI using this Mailbox function. Unlike the in-band MSR interface, this TCONTROL value is already adjusted to be in the native PECI temperature format of a 2-byte, 2’s complement number. 6.3.2.6.7 Thermal Data Config Read / Write The Thermal Data Configuration register allows the PECI host to control the window over which thermal data is filtered. The default window is 256 ms. The host may configure this window by writing a Thermal Filtering Constant as a power of two. For 9 or 512 ms. example, sending a value of 9 results in a filtering window of 2 Figure 6-20. Thermal Data Configuration Register 3 1 43 0 Reserved Thermal Filter Const 6.3.2.6.8 Machine Check Read PECI offers read access to processor machine check banks 0, 1, 6 and 8. Because machine check bank reads must be delivered through the Intel Xeon processor 5500 series Power Control Unit, it is possible that a fatal error in that unit will prevent access to other machine check banks. Host controllers may read Power Control Unit errors directly by issuing a PCIConfigRd() command of address 0x000000B0. Figure 6-21. Machine Check Read MbxSend() Data Format Byte # 0 1 2 3 4 0x0A Bank Index Bank Number Reserved Data Request Type Data[31:0] ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 117 Thermal Specifications Table 6-21. Machine Check Bank Definitions Bank Number Bank Index Meaning 0 0 MC0_CTL[31:0] 0 1 MC0_CTL[63:32] 0 2 MC0_STATUS[31:0] 0 3 MC0_STATUS[63:32] 0 4 MC0_ADDR[31:0] 0 5 MC0_ADDR[63:32] 0 6 MC0_MISC[31:0] 0 7 MC0_MISC[63:32] 1 0 MC1_CTL[31:0] 1 1 MC1_CTL[63:32] 1 2 MC1_STATUS[31:0] 1 3 MC1_STATUS[63:32] 1 4 MC1_ADDR[31:0] 1 5 MC1_ADDR[63:32] 1 6 MC1_MISC[31:0] 1 7 MC1_MISC[63:32] 6 0 MC6_CTL[31:0] 6 1 MC6_CTL[63:32] 6 2 MC6_STATUS[31:0] 6 3 MC6_STATUS[63:32] 6 4 MC6_ADDR[31:0] 6 5 MC6_ADDR[63:32] 6 6 MC6_MISC[31:0] 6 7 MC6_MISC[63:32] 8 0 MC8_CTL[31:0] 8 1 MC8_CTL[63:32] 8 2 MC8_STATUS[31:0] 8 3 MC8_STATUS[63:32] 8 4 MC8_ADDR[31:0] 8 5 MC8_ADDR[63:32] 8 6 MC8_MISC[31:0] 8 7 MC8_MISC[63:32] 6.3.2.6.9 T-state Throttling Control Read / Write PECI offers the ability to enable and configure ACPI T-state (core clock modulation) throttling. ACPI T-state throttling forces all CPU cores into duty cycle clock modulation where the core toggles between C0 (clocks on) and C1 (clocks off) states at the specified duty cycle. This throttling reduces CPU performance to the duty cycle specified and, more importantly, results in processor power reduction. The Intel Xeon processor 5500 series software initiated T-state throttling and automatic T-state throttling as part of the internal Thermal Monitor response mechanism (upon TCC activation). The PECI T-state throttling control register read/write capability is ® ® 118 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications managed only in the PECI domain. In-band software may not manipulate or read the PECI T-state control setting. In the event that multiple agents are requesting T-state throttling simultaneously, the CPU always gives priority to the lowest power setting, or the numerically lowest duty cycle. On Intel Xeon processor 5500 series, the only supported duty cycle is 12.5% (12.5% clocks on, 87.5% clocks off). It is expected that T-state throttling will be engaged only under emergency thermal or power conditions. Future products may support more duty cycles, as defined in the following table: Table 6-22. ACPI T-state Duty Cycle Definition Duty Cycle Code Definition 0x0 Undefined 0x1 12.5% clocks on / 87.5% clocks off 0x2 25% clocks on / 75% clocks off 0x3 37.5% clocks on / 62.5% clocks off 0x4 50% clocks on / 50% clocks off 0x5 62.5% clocks on / 37.5% clocks off 0x6 75% clocks on / 25% clocks off 0x7 87.5% clocks on / 12.5% clocks off The T-state control word is defined as follows: \ Figure 6-22. ACPI T-state Throttling Control Read / Write Definition Byte # 0 1 2 3 4 Request Type Request Data 7 543 10 70 0xB / 0xC Reserved Data Enable Duty Cycle 6.3.2.7 MbxSend() The MbxSend() command is utilized for sending requests to the generic Mailbox interface. Those requests are in turn serviced by the processor with some nominal latency and the result is deposited in the mailbox for reading. MbxGet() is used to retrieve the response and details are documented in Section 6.3.2.8. The details of processor mailbox capabilities are described in Section 6.3.2.6.1, and many of the fundamental concepts of Mailbox ownership, release, and management are discussed in Section 6.3.2.9. 6.3.2.7.1 Write Data Regardless of the function of the mailbox command, a request type modifier and 4-byte data payload must be sent. For Mailbox commands where the 4-byte data field is not applicable (for example, the command is a read), the data written should be all zeroes. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 119 Thermal Specifications Figure 6-23. MbxSend() Command Data Format 0 1 234 Byte # Byte Request Type Data[31:0] Definition Because a particular MbxSend() command may specify an update to potentially critical registers inside the processor, it includes an Assured Write FCS (AW FCS) byte as part of the write data payload. In the event that the AW FCS mismatches with the client- calculated FCS, the client will abort the write and will always respond with a bad Write FCS. 6.3.2.7.2 Command Format The MbxSend() format is as follows: Write Length: 7 Read Length: 1 Command: 0xd1 Multi-Domain Support: Yes (see Table 6-26) Description: Deposits the Request Type and associated 4-byte data in the Mailbox interface and returns a completion code byte with the details of the execution results. Refer to Section 6.3.4.2 for completion code definitions. Figure 6-24. MbxSend() Byte # 0 1 2 3 Byte Write Length Read Length Cmd Code Client Address Definition 0x07 0x01 0xd1 4 5 6 7 8 Request Type LSB Data[31:0] MSB 9 10 10 11 11 12 Completion AW FCS FCS FCS Code Note that the 4-byte data defined above is sent in standard PECI ordering with LSB first and MSB last. ® ® 120 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Table 6-23. MbxSend() Response Definition Response Meaning Bad FCS Electrical error CC: 0x4X Semaphore is granted with a Transaction ID of ‘X’ CC: 0x80 Error causing a response timeout. Either due to a rare, internal timing condition or a processor RESET condition or processor S1 state. Retry is appropriate outside of the RESET or S1 states. CC: 0x86 Mailbox interface is unavailable or busy If the MbxSend() response returns a bad Read FCS, the completion code can't be trusted and the semaphore may or may not be taken. In order to clean out the interface, an MbxGet() must be issued and the response data should be discarded. 6.3.2.8 MbxGet() The MbxGet() command is utilized for retrieving response data from the generic Mailbox interface as well as for unlocking the acquired mailbox. Please refer to Section 6.3.2.7 for details regarding the MbxSend() command. Many of the fundamental concepts of Mailbox ownership, release, and management are discussed in Section 6.3.2.9. 6.3.2.8.1 Write Data The MbxGet() command is designed to retrieve response data from a previously deposited request. In order to guarantee alignment between the temporally separated request (MbxSend) and response (MbxGet) commands, the originally granted Transaction ID (sent as part of the passing MbxSend() completion code) must be issued as part of the MbxGet() request. Any mailbox request made with an illegal or unlocked Transaction ID will get a failed completion code response. If the Transaction ID matches an outstanding transaction ID associated with a locked mailbox, the command will complete successfully and the response data will be returned to the originator. Unlike MbxSend(), no Assured Write protocol is necessary for this command because this is a read-only function. 6.3.2.8.2 Command Format The MbxGet() format is as follows: Write Length: 2 Read Length: 5 Command: 0xd5 Multi-Domain Support: Yes (see Table 6-26) Description: Retrieves response data from mailbox and unlocks / releases that mailbox resource. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 121 Thermal Specifications Figure 6-25. MbxGet() Byte # 0 1 2 3 Byte Write Length Read Length Cmd Code Client Address Definition 0x02 0x05 0xd5 4 10 5 5 11 6 6 Completion Transaction ID FCS Code 7 10 5 8 11 6 9 10 11 LSB Response Data[31:0] FCS MSB Note that the 4-byte data response defined above is sent in standard PECI ordering with LSB first and MSB last. Table 6-24. MbxGet() Response Definition Response Meaning Aborted Write FCS Response data is not ready. Command retry is appropriate. CC: 0x40 Command passed, data is valid CC: 0x80 Error causing a response timeout. Either due to a rare, internal timing condition or a processor RESET condition or processor S1 state. Retry is appropriate outside of the RESET or S1 states. CC: 0x81 Thermal configuration data was malformed or exceeded limits. CC: 0x82 Thermal status mask is illegal CC: 0x83 Invalid counter select CC: 0x84 Invalid Machine Check Bank or Index CC: 0x85 Failure due to lack of Mailbox lock or invalid Transaction ID CC: 0x86 Mailbox interface is unavailable or busy CC: 0xFF Unknown/Invalid Mailbox Request 6.3.2.9 Mailbox Usage Definition 6.3.2.9.1 Acquiring the Mailbox The MbxSend() command is used to acquire control of the PECI mailbox and issue information regarding the specific request. The completion code response indicates whether or not the originator has acquired a lock on the mailbox, and that completion code always specifies the Transaction ID associated with that lock (see Section 6.3.2.9.2). Once a mailbox has been acquired by an originating agent, future requests to acquire that mailbox will be denied with an ‘interface busy’ completion code response. The lock on a mailbox is not achieved until the last bit of the MbxSend() Read FCS is transferred (in other words, it is not committed until the command completes). If the host aborts the command at any time prior to that bit transmission, the mailbox lock will be lost and it will remain available for any other agent to take control. ® ® 122 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.3.2.9.2 Transaction ID For all MbxSend() commands that complete successfully, the passing completion code (0x4X) includes a 4-bit Transaction ID (‘X’). That ID is the key to the mailbox and must be sent when retrieving response data and releasing the lock by using the MbxGet() command. The Transaction ID is generated internally by the processor and has no relationship to the originator of the request. On Intel Xeon processor 5500 series, only a single outstanding Transaction ID is supported. Therefore, it is recommended that all devices requesting actions or data from the Mailbox complete their requests and release their semaphore in a timely manner. In order to accommodate future designs, software or hardware utilizing the PECI mailbox must be capable of supporting Transaction IDs between 0 and 15. 6.3.2.9.3 Releasing the Mailbox The mailbox associated with a particular Transaction ID is only unlocked / released upon successful transmission of the last bit of the Read FCS. If the originator aborts the transaction prior to transmission of this bit (presumably due to an FCS failure), the semaphore is maintained and the MbxGet() command may be retried. 6.3.2.9.4 Mailbox Timeouts The mailbox is a shared resource that can result in artificial bandwidth conflicts among multiple querying processes that are sharing the same originator interface. The interface response time is quick, and with rare exception, back to back MbxSend() and MbxGet() commands should result in successful execution of the request and release of the mailbox. In order to guarantee timely retrieval of response data and mailbox release, the mailbox semaphore has a timeout policy. If the PECI bus has a cumulative ‘0 time of 1ms since the semaphore was acquired, the semaphore is automatically cleared. In the event that this timeout occurs, the originating agent will receive a failed completion code upon issuing a MbxGet() command, or even worse, it may receive corrupt data if this MbxGet() command so happens to be interleaved with an MbxSend() from another process. Please refer to Table 6-24 for more information regarding failed completion codes from MbxGet() commands. Timeouts are undesirable, and the best way to avoid them and guarantee valid data is for the originating agent to always issue MbxGet() commands immediately following MbxSend() commands. Alternately, mailbox timeout can be disabled. BIOS may write MSR MISC_POWER_MGMT (0x1AA), bit 11 to 0b1 in order to force a disable of this automatic timeout. 6.3.2.9.5 Response Latency The PECI mailbox interface is designed to have response data available within plenty of margin to allow for back-to-back MbxSend() and MbxGet() requests. However, under rare circumstances that are out of the scope of this specification, it is possible that the response data is not available when the MbxGet() command is issued. Under these circumstances, the MbxGet() command will respond with an Abort FCS and the originator should re-issue the MbxGet() request. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 123 Thermal Specifications 6.3.3 Multi-Domain Commands The Intel Xeon processor 5500 series does not support multiple domains, but it is possible that future products will, and the following tables are included as a reference for domain-specific definitions. Table 6-25. Domain ID Definition Domain ID Domain Number 0b01 0 0b10 1 Table 6-26. Multi-Domain Command Code Reference Domain 0 Domain 1 Command Name Code Code GetTemp() 0x01 0x02 PCIConfigRd() 0xC1 0xC2 PCIConfigWr() 0xC5 0xC6 MbxSend() 0xD1 0xD2 MbxGet() 0xD5 0xD6 6.3.4 Client Responses 6.3.4.1 Abort FCS The Client responds with an Abort FCS under the following conditions: • The decoded command is not understood or not supported on this processor (this includes good command codes with bad Read Length or Write Length bytes). • Data is not ready. • Assured Write FCS (AW FCS) failure. Note that under most circumstances, an Assured Write failure will appear as a bad FCS. However, when an originator issues a poorly formatted command with a miscalculated AW FCS, the client will intentionally abort the FCS in order to guarantee originator notification. 6.3.4.2 Completion Codes Some PECI commands respond with a completion code byte. These codes are designed to communicate the pass/fail status of the command and also provide more detailed information regarding the class of pass or fail. For all commands listed in Section 6.3.2 that support completion codes, each command’s completion codes is listed in its respective section. What follows are some generalizations regarding completion codes. An originator that is decoding these commands can apply a simple mask to determine pass or fail. Bit 7 is always set on a failed command, and is cleared on a passing command. Table 6-27. Completion Code Pass/Fail Mask 0xxx xxxxb Command passed 1xxx xxxxb Command failed ® ® 124 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications Table 6-28. Device Specific Completion Code (CC) Definition Completion Description Code 0x00..0x3F Device specific pass code 0x40 Command Passed 0x4X Command passed with a transaction ID of ‘X’ (0x40 | Transaction_ID[3:0]) 0x50..0x7F Device specific pass code CC: 0x80 Error causing a response timeout. Either due to a rare, internal timing condition or a processor RESET condition or processor S1 state. Retry is appropriate outside of the RESET or S1 states. CC: 0x81 Thermal configuration data was malformed or exceeded limits. CC: 0x82 Thermal status mask is illegal CC: 0x83 Invalid counter select CC: 0x84 Invalid Machine Check Bank or Index CC: 0x85 Failure due to lack of Mailbox lock or invalid Transaction ID CC: 0x86 Mailbox interface is unavailable or busy CC:0xFF Unknown/Invalid Mailbox Request Note: The codes explicitly defined in this table may be useful in PECI originator response algorithms. All reserved or undefined codes may be generated by a PECI client device, and the originating agent must be capable of tolerating any code. The Pass/Fail mask defined in Table 6-27 applies to all codes and general response policies may be based on that limited information. 6.3.5 Originator Responses The simplest policy that an originator may employ in response to receipt of a failing completion code is to retry the request. However, certain completion codes or FCS responses are indicative of an error in command encoding and a retry will not result in a different response from the client. Furthermore, the message originator must have a response policy in the event of successive failure responses. Please refer to the definition of each command in Section 6.3.2 for a specific definition of possible command codes or FCS responses for a given command. The following response policy definition is generic, and more advanced response policies may be employed at the discretion of the originator developer. Table 6-29. Originator Response Guidelines Response After 1 Attempt After 3 attempts Bad FCS Retry Fail with PECI client device error Abort FCS Retry Fail with PECI client device error. May be due to illegal command codes. CC: Fail Retry Either the PECI client doesn’t support the current command code, or it has failed in its attempts to construct a response. None (all 0’s) Force bus idle Fail with PECI client device error. Client may be dead or otherwise non- (1ms low), retry responsive (in RESET or S1, for example). CC: Pass Pass n/a Good FCS Pass n/a ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 125 Thermal Specifications 6.3.6 Temperature Data 6.3.6.1 Format The temperature is formatted in a 16-bit, 2’s complement value representing a number of 1/64 degrees centigrade. This format allows temperatures in a range of ±512°C to be reported to approximately a 0.016°C resolution. Figure 6-26. Temperature Sensor Data Format MSB MSB LSB LSB Upper nibble Lower nibble Upper nibble Lower nibble S x x x x x x x x x x x x x x x Sign Integer Value (0-511) Fractional Value (~0.016) 6.3.6.2 Interpretation The resolution of the processor’s Digital Thermal Sensor (DTS) is approximately 1°C, which can be confirmed by a RDMSR from IA32_THERM_STATUS MSR (0x19C) where it is architecturally defined. PECI temperatures are sent through a configurable low-pass filter prior to delivery in the GetTemp() response data. The output of this filter produces temperatures at the full 1/64°C resolution even though the DTS itself is not this accurate. Temperature readings from the processor are always negative in a 2’s complement format, and imply an offset from the reference TCC activation temperature. As an example, assume that the TCC activation temperature reference is 100°C. A PECI thermal reading of -10 indicates that the processor is running approximately 10°C below the TCC activation temperature, or 90°C. PECI temperature readings are not reliable at temperatures above TCC activation (since the processor is operating out of specification at this temperature). Therefore, the readings are never positive. 6.3.6.3 Temperature Filtering The processor digital thermal sensor (DTS) provides an improved capability to monitor device hot spots, which inherently leads to more varying temperature readings over short time intervals. Coupled with the fact that typical fan speed controllers may only read temperatures at 4 Hz, it is necessary for the thermal readings to reflect thermal trends and not instantaneous readings. Therefore, PECI supports a configurable low- pass temperature filtering function. By default, this filter results in a thermal reading that is a moving average of 256 samples taken at approximately 1msec intervals. This filter’s depth, or smoothing factor, may be configured to between 1 sample and 1024 samples, in powers of 2. See the equation below for reference where the configurable variable is ‘X’. X T = T + 1/2 * (T - T ) N N-1 SAMPLE N-1 Please refer to Section 6.3.2.6.7 for the definition of the thermal configuration command. ® ® 126 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications 6.3.6.4 Reserved Values Several values well out of the operational range are reserved to signal temperature sensor errors. These are summarized in the table below: Table 6-30. Error Codes and Descriptions Error Code Description 0x8000 General Sensor Error (GSE) 6.3.7 Client Management 6.3.7.1 Power-up Sequencing The PECI client is fully reset during processor RESET# assertion. This means that any transactions on the bus will be completely ignored, and the host will read the response from the client as all zeroes. After processor RESET# deassertion, the Intel Xeon processor 5500 series PECI client is operational enough to participate in timing negotiations and respond with reasonable data. However, the client data is not guaranteed to be fully populated until approximately 500 µS after processor RESET# is deasserted. Until that time, data may not be ready for all commands. The client responses to each command are as follows: Table 6-31. PECI Client Response During Power-Up (During ‘Data Not Ready’) Command Response Ping() Fully functional GetDIB() Fully functional GetTemp() Client responds with a ‘hot’ reading, or 0x0000 PCIConfigRd() Fully functional PCIConfigWr() Fully functional MbxSend() Fully functional MbxGet() Client responds with Abort FCS (if MbxSend() has been previously issued) In the event that the processor is tri-stated using power-on-configuration controls, the PECI client will also be tri-stated. Processor tri-state controls are described in Section 7. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 127 Thermal Specifications Figure 6-27. PECI Power-up Timeline Vtt VttPwrGd SupplyVcc Bclk VccPwrGd RESET# Mclk CSI pins CSI training idle running Reset uCode Boot BIOS uOp execution In Reset Data Not Rdy Fully Operational PECI Client Status x PECI Node ID 0b1 or 0b0 6.3.7.2 Device Discovery The PECI client is available on all processors, and positive identification of the PECI revision number can be achieved by issuing the GetDIB() command. Please refer to Section 6.3.2.2 for details on GetDIB response formatting. 6.3.7.3 Client Addressing The PECI client assumes a default address of 0x30. If nothing special is done to the processor, all PECI clients will boot with this address. For DP enabled parts, a special PECI_ID# pin is available to strap each PECI socket to a different node ID. The package pin strap is evaluated at the assertion of VCCPWRGOOD (as depicted in Figure 6-27). Since PECI_ID# is active low, tying the pin to ground results in a client address of 0x31, and tying it to V results in a client address of 0x30. TT The client address may not be changed after VCCPWRGOOD assertion, until the next power cycle on the processor. Removal of a processor from its socket or tri-stating a processor in a DP configuration will have no impact to the remaining non-tri-stated PECI client address. 6.3.7.4 C-States The Intel Xeon processor 5500 series PECI client is fully functional under all core and package C-states. Support for package C-states is a function of processor SKU and platform capabilities. All package C-states (C1/C1E, C3, and C6) are annotated here for completeness, but actual processor support for these C-states may vary. Because the Intel Xeon processor 5500 series takes aggressive power savings actions under the deepest C-states (C1/C1E, C3, and C6), PECI requests may have an impact to platform power. The impact is documented below: • Ping(), GetDIB(), GetTemp() and MbxGet() have no measurable impact on processor power under C-states. ® ® 128 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Thermal Specifications • MbxSend(), PCIConfigRd() and PCIConfigWr() usage under package C-states may result in increased power consumption because the processor must temporarily return to a C0 state in order to execute the request. The exact power impact of a pop-up to C0 varies by product SKU, the C-state from which the pop-up is initiated, and the negotiated T . BIT Table 6-32. Power Impact of PECI Commands versus C-states Command Power Impact Ping() Not measurable GetDIB() Not measurable GetTemp() Not measurable PCIConfigRd() Requires a package ‘pop-up’ to a C0 state PCIConfigWr() Requires a package ‘pop-up’ to a C0 state MbxSend() Requires a package ‘pop-up’ to a C0 state MbxGet() Not measurable 6.3.7.5 S-States The PECI client is always guaranteed to be operational under S0 and S1 sleep states. Under S3 and deeper sleep states, the PECI client response is undefined and therefore unreliable. Table 6-33. PECI Client Response During S1 Command Response Ping() Fully functional GetDIB() Fully functional GetTemp() Fully functional PCIConfigRd() Fully functional PCIConfigWr() Fully functional MbxSend() Fully functional MbxGet() Fully functional 6.3.7.6 Processor Reset The Intel Xeon processor 5500 series PECI client is fully reset on all RESET# assertions. Upon deassertion of RESET#, where power is maintained to the processor (otherwise known as a ‘warm reset’), the following are true: • The PECI client assumes a bus Idle state. • The Thermal Filtering Constant is retained. • PECI Node ID is retained. • GetTemp() reading resets to 0x0000. • Any transaction in progress is aborted by the client (as measured by the client no longer participating in the response). • The processor client is otherwise reset to a default configuration. § ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 129 Thermal Specifications ® ® 130 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Features 7 Features 7.1 Power-On Configuration (POC) Several options can be configured by hardware. Power-On configuration (POC) functionality is provided by strapping VID signals (see Table 2-3) or sampled on the active-to-inactive transition of RESET#. For specifics on these options, please refer to Table 7-1. Please note that requests to execute Built-In Self Test (BIST) are not selected by hardware, but rather passed across the Intel QuickPath Interconnect link during initialization. Processors sample VID[2:0]/MSID[2:0] and VID[5:3]/CSC[2:0] around the asserting edge VTTPWRGOOD. Table 7-1. Power On Configuration Signal Options Configuration Option Signal Reference 1 Output tristate PROCHOT# Section 6.2.4 2, 3 PECI ID ODT/PECI_ID# Section 6.3.7.3 2, 3 MSID VID[2:0]/MSID[2:0] Table 2-3 2, 3 CSC VID[5:3]/CSC[2:0] Table 2-3 Notes: 1. Asserting this signal during RESET# de-assertion will select the corresponding option. Once selected, this option cannot be changed except via another reset. The processor does not distinguish between a "warm" reset and a "power-on" reset. Output tri-state via the PROCHOT# power-on configuration option is referred to as Fault Resilient Boot (FRB). 2. Latched when VTTPWRGOOD is asserted and all internal power good conditions are met. 3. See the signal definitions in Table 5-1 for the description of PECI_ID#, MSID, and CSC. Assertion of the PROCHOT# signal through RESET# de-assertion (also referred to as Fault Resilient Boot (FRB)) will tri-state processor outputs. Figure 7-1 outlines timing requirements when utilizing PROCHOT# as a power-on configuration option. In the event an FRB is desired, PROCHOT# and RESET# should be asserted simultaneously. Furthermore, once asserted, PROCHOT# should remain low long enough to meet the Power-On Configuration Hold Time (PROCHOT#). Failure to do so may result in false tri-state. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 131 Features Figure 7-1. PROCHOT# POC Timing Requirements Min Setup (2) Min Hold (106) BCLK CPURESET# Tri-State POC (xxPROCHOT#) Non-FRB assertion of xxPROCHOT# during this window can trigger false tri-state xxPROCHOT# deassertion is not required for FRB Power-On Configuration (POC) logic levels are MUX-ed onto the VID[7:0] signals with 1-5 KΩ pull-up and pull-down resistors located on the baseboard. These include: • VID[2:0] / MSID[2:0] = Market Segment ID • VID[5:3] / CSC[2:0] = Current Sense Configuration • VID[6] = Reserved • VID[7] = VR11.1 Select Pull-up and pull-down resistors on the baseboard eliminate the need for timing specifications After the voltage regulator’s OUTEN signal is asserted, the VID[7:0] CMOS drivers (typically 50Ω up / down impedance) override the POC pull-up / down resistors located on the baseboard and drive the necessary VID pattern. Please refer to Table 2-3 for further details. 7.2 Clock Control and Low Power States The processor supports low power states at the individual thread, core, and package level for optimal power management. The processor implements software interfaces for requesting low power states: MWAIT instruction extensions with sub-state hints, the HLT instruction (for C1 and C1E) and P_LVLx reads to the ACPI P_BLK register block mapped in the processor’s I/O address space. The P_LVLx I/O reads are converted to equivalent MWAIT C-state requests inside the processor and do not directly result in I/O reads to the system. The P_LVLx I/O Monitor address does not need to be set up before using the P_LVLx I/O read interface. Note: Software may make C-state requests by using a legacy method involving I/O reads from the ACPI-defined processor clock control registers, referred to as P_LVLx. This feature is designed to provide legacy support for operating systems that initiate C-state transitions via access to pre-defined ICH registers. The base P_LVLx register is P_LVL2, corresponding to a C3 request. P_LVL3 is C6, and all P_LVL4+ are demoted to a C6. P_LVLx is limited to a subset of C-states supported on the processor (for example, P_LVL8 is not supported and will not cause an I/O redirection to a C8 request. Instead, it will fall through like a normal I/O instruction). The range of I/O addresses that may be converted into C-state requests is also defined in the PMG_IO_CAPTURE MSR, in the ® ® 132 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Features ‘C-state Range’ field. This field maybe written by BIOS to restrict the range of I/O addresses that are trapped and redirected to MWAIT instructions. Note that when I/O instructions are used, no MWAIT substates can be defined, as therefore the request defaults to have a sub-state or zero, but always assumes the ‘break on EFLAGS.IF==0’ control that can be selected using ECX with an MWAIT instruction. Figure 7-2. Power States C0 MWAIT C1, HLT MWAIT C6, 2 2 I/O C6 2 2 MWAIT C1, MWAIT C3, HLT (C1E I/O C3 enabled) 1 1 C3 C6 C1 CE 1 1. No transition to C0 is needed to service a snoop when in C1 or C1E. , . 2. Transitions back to C0 occur on an interrupt or on access to monitored address (if state was entered via MWAIT). . 7.2.1 Thread and Core Power State Descriptions Individual threads may request low power states as described below. Core power states are automatically resolved by the processor as shown in Table 7-2. Table 7-2. Coordination of Thread Power States at the Core Level Core State Thread 1 State 1 Thread 0 State C0 C1 C3 C6 C0 C0 C0 C0 C0 1 1 1 1 C1 C1 C1 C1 C0 1 C3 C0 C1 C3 C3 1 C6 C0 C1 C3 C6 Notes: 1. If enabled, state will be C1E. 7.2.1.1 C0 State This is the normal operating state in the processor. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 133 Features 7.2.1.2 C1/C1E State C1/C1E is a low power state entered when all threads within a core execute a HLT or MWAIT(C1E) instruction. The processor thread will transition to the C0 state upon occurrence of an interrupt or an access to the monitored address if the state was entered via the MWAIT instruction. RESET# will cause the processor to initialize itself and return to C0. A System Management Interrupt (SMI) handler will return execution to either Normal state or the C1/C1E state. See the Intel® 64 and IA-32 Architectures Software Developer's Manual, Volume III: System Programmer's Guide for more information. While in C1/C1E state, the processor will process bus snoops and snoops from the other threads. To operate within specification, BIOS must enable the C1E feature for all installed processors. 7.2.1.3 C3 State Individual threads of the processor can enter the C3 state by initiating a P_LVL2 I/O read to the P_BLK or an MWAIT(C3) instruction. Before entering core C3, the core flushes the contents of its caches. Except for the caches, the processor core maintains all its architectural state while in the C3 state. All of the clocks in the processor core are stopped in the C3 state. Because the core’s caches are flushed, the processor keeps the core in the C3 state when the processor detects a snoop on the Intel QuickPath Interconnect Link or when another logical processor in the same package accesses cacheable memory. The processor core will transition to the C0 state upon occurrence of an interrupt. RESET# will cause the processor core to initialize itself. 7.2.1.4 C6 State Individual threads of the processor can enter the C6 state by initiating a P_LVL3 read to the P_BLK or an MWAIT(C6) instruction. Before entering core C6, the processor saves it state. The processor achieves additional power savings in the core C6 state. 7.2.2 Package Power State Descriptions The package supports C0, C1/C1E, C3, and C6 power states. The package power state is automatically resolved by the processor depending on the core power states and permission from the rest of the system as described below. 7.2.2.1 Package C0 State This is the normal operating state for the processor. The processor remains in the Normal state when at least one of its cores is in the C0 or C1 state or when another component in the system has not granted permission to the processor to go into a low power state. Individual components of the processor may be in low power states while the package in C0. 7.2.2.2 Package C1/C1E State The package will enter the C1/C1E low power state when at least one core is in the C1/C1E state and the rest of the cores are in the C1/C1E or lower power state. The processor will also enter the C1/C1E state when all cores are in a power state lower ® ® 134 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Features than C1/C1E but the package low power state is limited to C1/C1E via the PMG_CST_CONFIG_CONTROL MSR. In the C1E state, the processor will automatically transition to the lowest power operating point (lowest supported voltage and associated frequency). When entering the C1E state, the processor will first switch to the lowest bus ratio and then transition to the lower VID. No notification to the system occurs upon entry to C1/C1E. To operate within specification, BIOS must enable the C1E feature for all installed processors. 7.2.2.3 Package C3 State The package will enter the C3 low power state when all cores are in the C3 or lower power state and the processor has been granted permission by the other component(s) in the system to enter the C3 state. The package will also enter the C3 state when all cores are in an idle state lower than C3 but other component(s) in the system have only granted permission to enter C3. If Intel QuickPath Interconnect L1 has been granted, the processor will disable some clocks and PLLs and for processors with an Integrated Memory Controller, the DRAM will be put into self-refresh. 7.2.2.4 Package C6 State The package will enter the C6 low power state when all cores are in the C6 or lower power state and the processor has been granted permission by the other component(s) in the system to enter the C6 state. The package will also enter the C6 state when all cores are in an idle state lower than C6 but the other component(s) have only granted permission to enter C6. If Intel QuickPath Interconnect L1 has been granted, the processor will disable some clocks and PLLs and the shared cache will enter a deep sleep state. Additionally, for processors with an Integrated Memory Controller, the DRAM will be put into self- refresh. 7.2.3 Intel Xeon Processor 5500 Series C-State Power Specifications Table 7-3 lists C-State power specifications for various Intel Xeon processor 5500 series SKUs. Table 7-3. Processor C-State Power Specifications Package 2 3 130W 95W 80W 60W 38W 1 C-State C1E 35 W 30 W 30/40 W 22 W 16 W C3 30 W 26 W 26/35 W 18 W 12 W C6 12 W 10 W 10/15 W 8 W 8 W Notes: 1. Specifications are at T = 50C with all cores in the specified C-State. case 2. Standard/Basic SKUs. ® ® 3. Applies to Low Power SKU and Intel Xeon Processor L5518. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 135 Features 7.3 Sleep States The processor supports the ACPI sleep states S0, S1, S3, and S4/S5 as shown in. For information on ACPI S-states and related terminology, refer to ACPI Specification. The S-state transitions are coordinated by the processor in response PM Request (PMReq) messages from the chipset. The processor itself will never request a particular S-state. Table 7-4. Processor S-States S-State Power Reduction Allowed Transitions S0 Normal Code Execution S1 (via PMReq) S1 Cores in C1E like state, processor responds with S0 (via reset or PMReq) CmpD(S1) message. S3, S4 (via PMReq) S3 Memory put into self-refresh, processor responds with S0 (via reset) CmpD(S3) message. S4/S5 Processor responds with CmpD(S4/S5) message. S0 (via reset) Notes: 1. If the chipset requests an S-state transition which is not allowed, a machine check error will be generated by the processor. ® 7.4 Intel Turbo Boost Technology The processor supports ACPI Performance States (P-States). The P-state referred to as ® ® P0 will be a request for Intel Turbo Boost Technology (Intel TBT). Intel TBT opportunistically, and automatically, allows the processor to run faster than the marked frequency if the part is operating below power, temperature and current limits. Max Turbo Boost frequency is dependent on the number of active cores and varies by processor line item configuration. Intel TBT doesn’t need special hardware support, and can be enabled or disabled by BIOS. ® 7.5 Enhanced Intel SpeedStep Technology ® The processor features Enhanced Intel SpeedStep Technology. Following are the key features of Enhanced Intel SpeedStep Technology: • Multiple voltage and frequency operating points provide optimal performance at the lowest power. • Voltage and frequency selection is software controlled by writing to processor MSRs: is ramped up — If the target frequency is higher than the current frequency, V CC in steps by placing new values on the VID pins and the PLL then locks to the new frequency. — If the target frequency is lower than the current frequency, the PLL locks to the new frequency and the V is changed through the VID pin mechanism. CC — Software transitions are accepted at any time. If a previous transition is in progress, the new transition is deferred until the previous transition completes. • The processor controls voltage ramp rates internally to ensure smooth transitions. • Low transition latency and large number of transitions possible per second: — Processor core (including shared cache) is unavailable for less than 2µs during the frequency transition. § ® ® 136 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications 8 Boxed Processor Specifications 8.1 Introduction Intel boxed processors are intended for system integrators who build systems from components available through distribution channels. The Intel Xeon processor 5500 series will be offered as an Intel boxed processor, however the thermal solution will be sold separately. Unlike previous-generation boxed processors, Intel Xeon processor 5500 series boxed processors will not include thermal solution in the box. Intel will offer boxed thermal solutions separately through the same distribution channels. Please reference Section 8.1.1 - Section 8.1.4 for more details on Boxed Processor Thermal Solutions. 8.1.1 Available Boxed Thermal Solution Configurations Intel will offer three different Boxed Heat Sink solutions to support the boxed Processors. • Boxed Intel “Combo” Thermal Solution. The Passive / Active Combination Heat Sink Solution is intended for processors with a TDP up to 130W in a pedestal or 2U+ chassis with appropriate ducting) • Boxed Intel “Active” Thermal Solution. The Active Heat Sink Solution is intended for processors with a TDP of 80W or lower in pedestal chassis • Boxed Intel “Passive” Thermal Solution. The 25.5 mm tall Passive Heat Sink Solution is intended for processors with a TDP of 95W or lower in Blades, 1U, or 2U chassis with appropriate ducting. 8.1.2 An Intel “Combo” Boxed Passive / Active Combination Heat Sink Solution The Passive / Active combination solution, based on a 2U passive heat sink with a removable fan, is intended for use with processors with TDP’s up to 130 W. This heat pipe based solution is intended to be used as either a passive heat sink in a 2U or larger chassis, or as an active heat sink for pedestal chassis. Figure 8-2 and Figure 8-3 are representations of the heat sink solution. Although the active combination solution with the removable fan installed mechanically fits into a 2U keepout, its use has not been validated in that configuration. The Passive / Active combination solution in the active fan configuration is primarily designed to be used in a pedestal chassis where sufficient air inlet space is present. The Passive / Active combination solution with the fan removed, as with any passive thermal solution, will require the use of chassis ducting and are targeted for use in rack mount or ducted pedestal servers. The retention solution used for these products is called Unified Retention System (URS). ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 137 Boxed Processor Specifications 8.1.3 Intel Boxed “Active” Heat Sink Solution The Boxed Active solution will be available for purchase for processors with TDP’s of 80W and lower and will be an aluminum extrusion. This heat sink solution is intended to be used as an active heat sink only for pedestal chassis. Figure 8-1 is a representation of the heat sink solution. Both active solutions will utilize a fan capable of 4-pin pulse width modulated (PWM) control. Use of a 4-pin PWM controlled active thermal solution helps customers meet acoustic targets in pedestal platforms through the baseboard’s ability to directly control the RPM of the processor heat sink fan. See Section 8.3 for more details on fan speed control, also see Section 6.3 for more on the PWM and PECI interface along with Digital Thermal Sensors (DTS). Figure 8-1. Boxed Active Heat Sink Figure 8-2. Boxed Passive / Active Combination Heat Sink (With Removable Fan) ® ® 138 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications Figure 8-3. Boxed Passive/Active Combination Heat Sink (with Fan Removed) Figure 8-4. Intel Boxed 25.5 mm Tall Passive Heat Sink Solution 8.1.4 Intel Boxed 25.5mm Tall Passive Heat Sink Solution The boxed 25.5 mm Tall heatsink solution will be available for use with boxed processors that have TDP’s of 95 W and lower. The 25.5 mm Tall passive solution is designed to be used in Blades, 1U, and 2U chassis where ducting is present. The use of a 25.5 mm Tall heatsink in a 2U chassis is recommended to achieve a lower heatsink T and a more optimized heatsink design. Figure 8-4 is a representation of the heat LA sink solution. The retention solution used for these products is called Unified Retention System (URS). ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 139 Boxed Processor Specifications 8.2 Mechanical Specifications This section documents the mechanical specifications of the boxed processor solution. 8.2.1 Boxed Processor Heat Sink Dimensions and Baseboard Keepout Zones The boxed processor and boxed thermal solution will be sold separately. Clearance is required around the thermal solution to ensure unimpeded airflow for proper cooling. Baseboard keepout zones are shown in Figure 8-5 through Figure 8-8. Physical space requirements and dimensions for the boxed processor and assembled heat sink are shown in Figure 8-9. Mechanical drawings for the 4-pin fan header and 4-pin connector used for the active fan heat sink solution are represented in Figure 8-11 and Figure 8-12. None of the heat sink solutions exceed a mass of 550 grams. Note that this is per processor, a dual processor system will have up to 1100 grams total mass in the heat sinks. See Section 3 for details on the processor mass. ® ® 140 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications Figure 8-5. Top Side Baseboard Keep-Out Zones ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 141 DWG. NO SHT. REV 8 7 6 5 4 3 D77712 102 1 THIS DRAWING CONTAINS INTEL CORPORAT ION CONFIDENTIAL INFORMATION. IT IS DISCLOSED IN CONFIDENCE AND ITS CONT ENTS MAY NOT BE DISCLOSED, REPRODUCED, DI SPLAYED OR MODIFIED, WITHOUT THE PRI OR WRITTEN CONSENT OF INTEL CORPORAT ION. NOTES: 1. THIS DRAWING TO BE USED IN CORELATION WITH SUPPLIED 3D DATA BASE FILE. ALL DIMENSIONS AND TOLERANCES ON THIS DRAWING TAKE PRECEDENCE OVER SUPPLIED FILE. 2. PRIMARY DIMENSIONS STATED IN MILLIMETERS. [BRACKATED] DIMENSIONS STATED IN INCHES 90.00 D D [3.543] MAX THERMAL 3. SOCKET KEEP OUT DIMENSIONS SHOWN FOR REFERNCE ONLY PLEASE REFER TO THE SOCKET B KEEPOUT / KEEPIN DRAWING RETENTION OUTLINE FOR EXACT DIMENSIONS 4 BALL 1 LOCATION WITH RESPECT TO SOCKET BALL ARRAY IS FORMED BY INTERSECTION OF ROW A & COLUMN 1. MAXIMUM 80.00 OUTLINE OF SOCKET SOLDERBALL ARRAY MUST BE PLACED [3.150] SYMMETRIC TO THE ILM HOLE PATTERN (INNER PATTERN) FOR THERMAL RETENTION PROPER ILM & SOCKET FUNCTION. HOLE PATTERN 5. A HEIGHT RESTRICTION ZONE IS DEFINED AS ONE WHERE ALL COMPONENTS PLACED ON THE SURFACE OF THE MOTHERBOARD MUST HAVE A MAXIMUM HEIGHT NO GREATER THAN THE HEIGHT 47.50 DEFINED BY THAT ZONE. [1.870] SOCKET BODY OUTLINE, ALL ZONES DEFINED WITHIN THE 90 X 90 MM FOR REFERENCE ONLY OUTLINE REPRESENT SPACE THAT RESIDES BENEATH THE HEAT SINK FOOTPRINT. UNLESS OTHERWISE NOTED ALL VIEW DIMENSION ARE NOMINAL. 41.66 ALL HEIGHT RESTRICTIONS ARE MAXIMUMS. NEITHER ARE [1.640] DRIVEN BY IMPLIED TOLERANCES. CENTERLINE OF OUTER SOCKET BALL ARRAY A HEIGHT RESTRICTION OF 0.0 MM REPRESENTS THE TOP (OR BOTTOM) SURFACE OF THE MOTHERBOARD AS THE MAXIMUM HEIGHT. 36.00 SEE NOTE 7 FOR ADDITIONAL DETAILS. [1.417] C C SOCKET ILM 6. SEE SHEET 4 FOR REVISION HISTORY. HOLE PATTERN 7 COMBINED COMPONENT AND SOLDER PASTE HEIGHT INCLUDING TOLERANCES AFTER REFLOW. 90.00 [3.543] MAX THERMAL RETENTION OUTLINE 80.00 [3.150] THERMAL RETENTION HOLE PATTERN 61.20 [2.409] SOCKET ILM HOLE PATTERN LEGEND, THIS SHEET ONLY B B 49.90 [1.965] SOCKET BODY OUTLINE, ZONE 1: FOR REFERENCE ONLY 0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT, SOCKET BODY OUTLINE SOCKET, ILM, AND FINGER ACCESS KEEPIN ZONE FOR REFERENCE ONLY 44.70 [1.760] ZONE 2: CENTERLINE OF OUTER SOCKET BALL ARRAY 7.0 MM MAX COMPONENT HEIGHT 7 ZONE 3: 3.0 MM MAX COMPONENT HEIGHT 7 ZONE 4: LINE REPRESENTS OF 0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT OUTERMOST ROWS AND COLUMNS RETENTION MODULE OR HEAT SINK TOUCH ZONE OF SOCKET BALL ARRAY OUTLINE. FOR REFERENCE ONLY ZONE 5: 0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT, NO ROUTE ZONE ZONE 6: BALL 1 POSITION 4 1.97 MM MAX COMPONENT HEIGHT, SOCKET CAVITY 7 DESIGNED BY DATE DEPARTMENT UNLESS OTHERWISE SPECIFIED 2200 MISSION COLLEGE BLVD. R INTERPRET DIMENSIONS AND TOLERANCES A N. ULEN 09/28/06 P.O. BOX 58119 A IN ACCORDANCE WITH ASME Y14.5-1994 DIMENSIONS ARE IN MILLIMETERS EASD / PTMI SANTA CLARA, CA 95052-8119 TOLERANCES: DRAWN BY DATE AS VIEWED FROM PRIMARY SIDE .X �# 0.0 Angles �# 0.0 TITLE .XX �# 0.00 N. ULEN 09/28/06 .XXX �# 0.000 CHECKED BY DATE OF THE MOTHERBOARD THIRD ANGLE PROJECTION J. WILLIAMS 11/03/06 THURLEY & GAINESTOWN ENABLING KEEPIN / KEEPOUT - - APPROVED BY DATE SIZE DRAWING NUMBER REV D 02 MATERIAL FINISH D77712 SCALE: 3.000 DO NOT SCALE DRAWINGSHEET 1 OF 4 8 7 6 5 4 3 2 1 Boxed Processor Specifications Figure 8-6. Top Side Baseboard Mounting-Hole Keep-Out Zones ® ® 142 Intel Xeon Processor 5500 Series Datasheet, Volume 1 DWG. NO SHT. REV 8 7 6 5 4 3 1 D77712 2 02 THIS DRAWING CONTAINS INTEL CORPORAT ION CONFIDENTIAL INFORMATION. IT IS DISCLOSED IN CONFIDENCE AND ITS CONT ENTS MAY NOT BE DISCLOSED, REPRODUCED, DI SPLAYED OR MODIFIED, WITHOUT THE PRI OR WRITTEN CONSENT OF INTEL CORPORAT ION. D D +0.06 4X 6.00 4X 3.80 NPTH -0.03 [] 0.236 NO ROUTE +0.002 0.150 COPPER PAD ON SURFACE [] -0.001 SOCKET ILM MOUNTING HOLES 5.00 [] 0.197 2X 0.00 [] 0.000 3.30 [] 0.130 2X 7.50 [] 0.295 2X 9.400 +0.06 4X 4.03 NPTH [] 0.3701 -0.03 +0.002 C 0.159 C 9.900 [] -0.001 [] 0.3898 THERMAL RETENTION MOUNTING HOLES 29.90 [] 1.177 30.600 [] 1.205 4X 6.00 [] 0.236 DETAIL A SCALE 6.000 49.40 [] 1.945 62.39 [] 2.456 B BALL 1 4 B 2X 70.600 [] 2.7795 2X 72.50 [] 2.854 LEGEND, THIS SHEET ONLY 77.90 [] 3.067 ZONE 1: 0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT, 3X 80.00 SOCKET, ILM, AND FINGER ACCESS KEEPIN ZONE [] 3.150 ZONE 2: 85.00 7.0 MM MAX COMPONENT HEIGHT 7 [] 3.346 ZONE 3: SEE DETAIL A 3.0 MM MAX COMPONENT HEIGHT 7 ZONE 4: 0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT RETENTION MODULE OR HEAT SINK TOUCH ZONE ZONE 5: 0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT, A A NO ROUTE ZONE ZONE 6: AS VIEWED FROM PRIMARY SIDE 1.97 MM MAX COMPONENT HEIGHT, SOCKET CAVITY 7 OF THE MOTHERBOARD DEPARTMENT SIZE DRAWING NUMBER REV R 2200 MISSION COLLEGE BLVD. (DETAILS) P.O. BOX 58119 D D77712 02 EASD / PTMI SANTA CLARA, CA 95052-8119 SCALE: 3.000 DO NOT SCALE DRAWINGSHEET 2 OF 4 8 7 6 5 4 3 2 1 5.00 [] 0.197 2X 0.00 [] 0.000 2X 7.50 [] 0.295 9.60 [] 0.378 12.30 [] 0.484 19.17 [] 0.755 BALL 1 4 22.000 [] 0.8661 32.85 [] 1.293 47.15 [] 1.856 58.000 [] 2.2835 67.70 [] 2.665 2X 72.50 [] 2.854 2X 80.00 [] 3.150 85.00 [] 3.346 Boxed Processor Specifications Figure 8-7. Bottom Side Baseboard Keep-Out Zones ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 143 DWG. NO SHT. REV 8 7 6 5 4 3 D77712 3 02 1 THIS DRAWING CONTAINS INTEL CORPORAT ION CONFIDENTIAL INFORMATION. IT IS DISCLOSED IN CONFIDENCE AND ITS CONT ENTS MAY NOT BE DISCLOSED, REPRODUCED, DI SPLAYED OR MODIFIED, WITHOUT THE PRI OR WRITTEN CONSENT OF INTEL CORPORAT ION. D D 5.00 [] 0.197 0.00 [] 0.000 5.00 [] 0.197 DESKTOP BACKPLATE KEEPIN SHOWN FOR 17.17 REFERENCE ONLY [] 0.676 C C 30.60 [] 1.205 (90.00 ) (72.20 ) [3.543] [2.843] 49.40 [] 1.945 62.83 [] 2.474 B B 75.00 [] 2.953 85.00 [] 3.346 (47.00 ) [1.850] 8X 6.00 [] 0.236 (90.00 ) [3.543] LEGEND, THIS SHEET ONLY ZONE 7: NO COMPONENT PLACEMENT, STIFFENING PLATE CONTACT AREA AS VIEWED FROM SECONDARY SIDE ZONE 8: A A 1.8 MM MAX COMPONENT HEIGHT 7 OF THE MOTHERBOARD (DETAILS) ZONE 9: NO COMPONENT PLACEMENT & NO ROUTE ZONE DEPARTMENT SIZE DRAWING NUMBER REV R 2200 MISSION COLLEGE BLVD. D D77712 02 P.O. BOX 58119 EASD / PTMI SANTA CLARA, CA 95052-8119 SCALE: 3.000 DO NOT SCALE DRAWINGSHEET 3 OF 4 8 7 6 5 4 3 2 1 85.00 [] 3.346 70.50 [] 2.776 47.15 [] 1.856 32.85 [] 1.293 9.50 [] 0.374 0.00 [] 0.000 5.00 [] 0.197 Boxed Processor Specifications Figure 8-8. Primary and Secondary Side 3D Height Restriction Zones ® ® 144 Intel Xeon Processor 5500 Series Datasheet, Volume 1 DWG. NO SHT. REV 8 7 6 5 4 3 D77712 4 02 1 THIS DRAWING CONTAINS INTEL CORPORAT ION CONFIDENTIAL INFORMATION. IT IS DISCLOSED IN CONFIDENCE AND ITS CONT ENTS MAY NOT BE DISCLOSED, REPRODUCED, DI SPLAYED OR MODIFIED, WITHOUT THE PRI OR WRITTEN CONSENT OF INTEL CORPORAT ION. REVISION HISTORY ZONE REV DESCRIPTION DATE APPROVED - - A ORIGINAL RELEASE 09/29/06 M.B COMPONENT HEIGHT RESTRICTION 10/05/06 B CHANGED FROM 2.5MM TO 7MM C ADDED ADDITION KO FOR RM, SHEET 1 10/27/06 D DRAWING RE-DO, ADDED BALL PATTERN, SOCKET 11/03/06 D D BODY, BALL 1, BACKSIDE WINDOW, GENERAL DRAWING CLARIFICATIONS. E UPDATED SOCKET KEEPIN OUTLINE TO REFLECT 11/30/06 RECENT CHANGES. SEE KEEPIN ZONE 1 OUTLINE, SHEETS 1 & 2. 2D3 F CORRECTED ILM HOLE DIAMETER. WAS SHOWING 12/18/06 RADIUS VALUE. 1.9 --> 3.8 2C1 UPDATED BACKPLATE HOLE DIAMTER SIZE FOR DT COMPATIBILITY. DIAMETER 4.0 --> 4.03 G REMOVED 3.0 MM HEIGHT RESTRICTION ZONE 01/12/07 THIS HEIGHT REPRESENTS AN ARBITRARY TO THE LEFT AND RIGHT OF SOCKET OUTLINE MOTHERBOARD THICKNESS H MOVED REVISION HISTORY TABLE TO SHEET 4 01/19/07 CORRECTED SOCKET SOLDERBALL ARRAY & POS 1C6 41.66 --> 40.64 (ARRAY SIZE) 1B5 44.85 --> 44.70 (ARRAY SIZE) 2B8 62.43 --> 62.39 (ARRAY POSITION) 2D6 19.17 --> 19.67 (ARRAY POSITION) 2D4 ADDED TOPSIDE CU PAD CALLOUT FOR ILM HOLES SEE DETAIL A, SHEET 2 I REVERTED SOCKET SOLDERBALL ARRAY 01/22/07 X DIRECTION SIZE AND POSITION TO REV G. 1C6 40.64 --> 41.66 (ARRAY WIDTH) 2D6 19.67 --> 19.17 (ARRAY POSITION) SOLDERBALL ARRAY OUTLINE REPRESENTS THE CENTERLINE OF THE OUTER BALL ROWS/COLS SHT 4 J ADDED ISO VIEW OF SECONDARY SIDE 02/06/07 C SHT 4 MOVED ISO VEWS TO SHEET 4 C SHT 3 MODIFIED BACKSIDE HEIGHT RESTRICTIONS FOR NEW BACKPLATE GEOMETRY SHT 1 ADDED NOTE 5 DETAILING HEIGHT RESTRICTION NOMENCLATURE REMOVED TOLERANCE BLOCK VALUES, SEE NOTE 5 K UPDATED ZONE 1 KEEPOUT ON SHEETS 1 & 2 02/27/07 TO ALLOW MORE SOCKET LEVER ARM ACCESS, PRIMARY SIDE LEFT SIDE OF ZONE 01 PRODUCTION RELEASE 08/02/07 ALL ZONES, SEE NOTE 5 3D HEIGHT RESTRICTION ZONES 02 ZONE 6 HEIGHT FROM 1.8MM --> 1.97MM 02/24/09 ADDED NOTE 7 B B A A SECONDARY SIDE DEPARTMENT SIZE DRAWING NUMBER REV R 2200 MISSION COLLEGE BLVD. 3D HEIGHT RESTRICTION ZONES D D77712 P.O. BOX 58119 02 EASD / PTMI SANTA CLARA, CA 95052-8119 SCALE: 2.500 DO NOT SCALE DRAWINGSHEET 4 OF 4 8 7 6 5 4 3 2 1 Boxed Processor Specifications Figure 8-9. Volumetric Height Keep-Ins ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 145 Boxed Processor Specifications Figure 8-10. Volumetric Height Keep-Ins ® ® 146 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications Figure 8-11. 4-Pin Fan Cable Connector (For Active Heat Sink) ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 147 Boxed Processor Specifications Figure 8-12. 4-Pin Base Baseboard Fan Header (For Active Heat Sink) ® ® 148 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications 8.2.2 Boxed Processor Retention Mechanism and Heat Sink Support (URS) Baseboards designed for use by a system integrator should include holes that are in proper alignment with each other to support the boxed processor. Refer to Figure 8-5 for mounting hole dimensions. Figure 8-13 illustrates the Unified Retention System (URS) and the Unified Backplate Assembly. The URS is designed to extend air-cooling capability through the use of larger heat sinks with minimal airflow blockage and bypass. URS retention transfers load to the baseboard via the Unified Backplate Assembly. The URS spring, captive in the heatsink, provides the necessary compressive load for the thermal interface material. For specific design details on the URS and the Unified Backplate please refer to the Intel® Xeon® Processor 5500 Series Thermal / Mechanical Design Guide. All components of the URS heat sink solution will be captive to the heat sink and will only require a Phillips screwdriver to attach to the Unified Backplate Assembly. When installing the URS the screws should be tightened until they will no longer turn easily. This should represent approximately 8 inch-pounds of torque. More than that may damage the retention mechanism components. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 149 Boxed Processor Specifications Figure 8-13. Thermal Solution Installation 8.3 Fan Power Supply (“Combo” and “Active” Solution) The 4-pin PWM controlled thermal solution is being offered to help provide better control over pedestal chassis acoustics. This is achieved though more accurate measurement of processor die temperature through the processor’s Digital Thermal Sensors. Fan RPM is modulated through the use of an ASIC located on the baseboard that sends out a PWM control signal to the 4th pin of the connector labeled as Control. This thermal solution requires a constant +12 V supplied to pin 2 of the active thermal solution and does not support variable voltage control or 3-pin PWM control. See Table 8-1 through Table 8-3 for details on the 4-pin active heat sink solution connectors. ® ® 150 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications The fan power header on the baseboard must be positioned to allow the fan heat sink power cable to reach it. The fan power header identification and location must be documented in the suppliers platform documentation, or on the baseboard itself. The baseboard fan power header should be positioned within 177.8 mm [7 in.] from the center of the processor socket. Table 8-1. PWM Fan Frequency Specifications For 4-Pin Active Thermal Solution Description Min Frequency Nominal Frequency Max Frequency Unit PWM Control 21,000 25,000 28,000 Hz Frequency Range Table 8-2. Fan Specifications For 4-Pin Active Thermal Solution Typ Max Max Description Min Unit Steady Steady Startup +12 V: 12 volt fan power supply 10.8 12 12 13.2 V IC: Fan Current Draw N/A 1.25 1.5 2.2 A Pulses per fan SENSE: SENSE frequency 2 2 2 2 revolution Figure 8-14. Fan Cable Connector Pin Out For 4-Pin Active Thermal Solution Table 8-3. Fan Cable Connector Pin Out for 4-Pin Active Thermal Solution Pin Number Signal Color 1Ground Black 2 Power: (+12 V) Yellow 3 Sense: 2 pulses per revolution Green 4 Control: 21 KHz-28 KHz Blue 8.3.1 Boxed Processor Cooling Requirements As previously stated the boxed processor will have three cooling solutions available. Each configuration will require unique design considerations. Meeting the processor’s temperature specifications is also the function of the thermal design of the entire system, and ultimately the responsibility of the system integrator. The processor temperature specifications are found in Section 6 of this document. ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 151 Boxed Processor Specifications 8.3.1.1 2U Passive / Active Combination Heat Sink Solution Active Configuration: The active configuration of the combination solution is designed to help pedestal chassis users to meet the thermal processor requirements without the use of chassis ducting. It may be still be necessary to implement some form of chassis air guide or air temperature of 40°C depending on the pedestal chassis layout. duct to meet the T LA Use of the active configuration in a 2U rackmount chassis is not recommended. It is recommended that the ambient air temperature outside of the chassis be kept at or below 35°C. The air passing directly over the processor thermal solution should not be preheated by other system components. Meeting the processor’s temperature specification is the responsibility of the system integrator. This thermal solution is for use with 95 W and 130 W TDP processor SKUs. Passive Configuration: In the passive configuration it is assumed that a chassis duct will be implemented. Processors with a TDP of 130 W or 95 W must provide a minimum airflow of 30 CFM at 3 0.205 in. H O (51 m /hr at 51.1 Pa) of flow impedance. For processors with a TDP of 2 130 W it is assumed that a 40°C T is met. This requires a superior chassis design to LA limit the T at or below 5°C with an external ambient temperature of 35°C. For RISE processors with a TDP of 95W it is assumed that a 55°C T is met. LA 8.3.1.2 Active Heat Sink Solution (Pedestal only) This active solution is designed to help pedestal chassis users to meet the thermal processor requirements without the use of chassis ducting. It may be still be necessary to implement some form of chassis air guide or air duct to meet the T temperature of LA 49°C depending on the pedestal chassis layout. Use of this active solution in a 2U rackmount chassis has not been validated. It is recommended that the ambient air temperature outside of the chassis be kept at or below 35°C. The air passing directly over the processor thermal solution should not be preheated by other system components. Meeting the processor’s temperature specification is the responsibility of the system integrator. This thermal solution is for use with processor SKUs no higher than 80W. 8.3.1.3 25.5 mm Tall Passive Heat Sink Solution (Blade + 1U + 2U Rack) Note: 95 W SKU’s using the 25.5 mm Tall passive HS are only intended for use in 1U rack configurations (Thermal Profile B). For use in 2U configurations see Section 8.3.1.2 for details. In the Blade, 1U and 2U configurations it is assumed that a chassis duct will be implemented. Due to the complexity of the number of chassis and baseboard configurations, several airflow and flow impedance values exist. Please refer to the Intel® Xeon® Processor 5500/5600 Series Thermal / Mechanical Design Guide for detailed mechanical drawings and specific airflow and impedance values applicable to your use conditions. It is recommended that the ambient air temperature outside of the chassis be kept at or below 35°C. ® ® 152 Intel Xeon Processor 5500 Series Datasheet, Volume 1 Boxed Processor Specifications 8.4 Boxed Processor Contents The Boxed Processor and Boxed Thermal Solution contents are outlined below. • Boxed Processor Contents — Intel Xeon processor 5500 series — Installation and warranty manual —Intel Inside Logo • Boxed Thermal Solution — Heat sink assembly solution — Thermal interface material (pre-applied on heat sink, if included) — Installation and warranty manual § ® ® Intel Xeon Processor 5500 Series Datasheet, Volume 1 153 Boxed Processor Specifications ® ® 154 Intel Xeon Processor 5500 Series Datasheet, Volume 1
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the BX80602E5504?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods