Part Number | BT-AIL-FAN |
---|---|
Manufacturer | GE INTELLIGENT PLATFORMS |
Category | AFDX/ARINC 664 |
Price | Request Quote |
Lead Time | Request Quote |
GE INTELLIGENT PLATFORMS BT-AIL-FAN, AFDX/ARINC 664 AFDX traffic analyzer file analysis
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a BT-AIL-FAN? We can help you find it at a competitive price!
Connections | High density 15-pin D-sub connector for In/Out triggers per port and four bi-directional avionics level discretes Transition cable is provided Two IEEE 802.3 compliant Ethernet RJ-45 connectors |
---|---|
Error Injection | CRC error Framing (byte alignment) error Physical symbol error Preamble (symbol and length) errors SFD (Start Frame Delimiter) error |
Ethernet Frame Reception | Ethernet frames transferred to host buffers via DMA High resolution time-tagging with 20 nsec resolution Link level error detection Min-to-copy capability |
Ethernet Frame Transmission | Ethernet frames transferred from host buffers via DMA Flexible scheduling modes, Minimum IFG delay (960 nsec between frames), Per-frame specified delays (multiple conditions), On external trigger, Playback delay modes Transmission scheduling with 20 nsec resolution |
Operating Temp Range | 0°C to 55°C |
Physical | Dimensions: Standard 54mm Express Card dimensions ExpressCard |
Port Parameters | Full Duplex IEEE 802.3 compliant ports Software-selectable 10/100 Mbps data rates Software-selectable auto-negotiation Software-selectable internal wrap |
Power (max.) | 3 Watts max |
Receive Statistics (64-bit counters) | Separate counter for Link level errors, Physical symbol, Invalid preamble symbol, Invalid or missing SFD, Unaligned frame, IFG too short, Frame too short, Frame too long, CRC errors |
Relative humidity | 5 to 90% |
Software | CFDX API Library Cpcap API Library Ethereal GUI for ntar file analysis Windows XP support. Contact factory about availability of support for additional operating environments (including LabVIEW.) |
Timing Reference | 64-bit time tag IRIG-B generator (TTL/DC) IRIG-B PPS synchronization with time tag IRIG-B receiver (AM or TTL/DC) Software-selectable internal wrap |
Transmit Statistics (64-bit counters) | Total bytes transmitted Total packets transmitted |
Triggering | Output when error packet received Output when error-free packet received Output when marked frame is transmitted Wait for external trigger to transmit |
Download "GE INTELLIGENT PLATFORMS-RAF-EC-2P-DATA SHEET -18659311361.pdf" (84 KiB)
GE Fanuc Intelligent Platforms RAF-EC-2P RoHS Dual Port ARINC 664 ExpressCard Interface Features Architecture Software • AFDX/ARINC 664 dual port interface (two GE Fanuc Intelligent Platforms’ RAF-EC-2P is The RAF-EC-2P comes with all the software independent 10/100 MHz duplex ports) a high performance interface for monitoring, development tools needed for user application generating or analyzing full-bandwidth AFDX- development at no extra charge. The Cpcap, • RoHS Compliant ARINC 664 protocol traffic. GE Fanuc Intelligent packet capture library, provides a complete • Includes AFDX and low-level Software Platforms’ exclusive pipeline architecture set of function for transmitting and receiving Developer’s Kit (SDK) at no additional charge maximizes packet throughput using parallel Ethernet frames. Frames from multiple ports • Advanced reception features controllers and efficient DMA transfers, can be logged or replayed using the open- - 20 nsec time-tags thereby avoiding the bottlenecks of CPU-based source ntar log-file format. CFDX implements - IRIG-B synchronization interface solutions. the ARINC 664/AFDX protocol stack including - DMA transfer to host End Systems, redundancy management, Virtual - Full throughput capability Configurable as either one dual-redundant Links and Ports. An advanced XML-based - Link level error detection AFDX/ARINC 664 interface or two independent Configuration File format is used to specify • Advanced Transmission Scheduling ports, users have complete access to all End Systems, and an AFDX-aware version of - Highly accurate frame and header data. Each incoming packet Ethereal is included to provide GUI analysis of - Flexible scheduling modes is tagged with a 20 nsec resolution, 64-bit logged files. - DMA transfer to host time-tag. Read time traffic generation is highly accurate. An IRIG-B receiver/generator is - Full throughput capability included for synchronization to external IRIG-B - Link level error detection time sources and for synchronizing multiple • Advanced Software Support CNIC boards. In addition, I/O triggers, error - Flexible packet capture API detection/injection, BIT, and link/protocol level - AFDX/ARINC 664 API statistics are provided. - XML configuration format - Integrated log file format AFDX/ARINC 664 Performance - Berkeley packet filter engine The RAF-EC-2P features two independent • Four bi-directional avionics level discretes 10/100 MHz duplex ports, capable of • Two input and output triggers per channel simultaneously receiving back to back Ethernet • Built-in test features frames with 12 byte interframe gaps at a rate of 100Mbps each. Each port is capable of transmitting back to back Ethernet frames with 12 byte interframe gaps at a rate of 100Mbps; with both ports transmitting simultaneously, current express card technology limits the total rate to not less than 50% rate for two channels simultaneously or 100% performance for one channel at a time. RAF-EC-2P: RoHS Dual Port ARINC 664 ExpressCard Interface Specifications Physical Receive Statistics (64-bit counters) Transmit Statistics (64-bit counters) • ExpressCard • Separate counter for Link level errors • Total packets transmitted • Dimensions: Standard 54mm - Physical symbol • Total bytes transmitted Express Card dimensions - Invalid preamble symbol Error Injection - Invalid or missing SFD Environmental • Physical symbol error - Unaligned frame • Operating Temp Range: 0°C to 55°C • Preamble (symbol and length) errors - IFG too short • Relative humidity: 5 to 90% • Framing (byte alignment) error - Frame too short • SFD (Start Frame Delimiter) error - Frame too long Software • CRC error - CRC errors • Windows XP support. Contact factory about availability of support for additional operating envi- Power (max.) Ethernet Frame Transmission ronments (including LabVIEW.) • 3 Watts max • Ethernet frames transferred from host buffers via • Cpcap API Library DMA • CFDX API Library • Transmission scheduling with 20 nsec resolution • Ethereal GUI for ntar file analysis • Flexible scheduling modes - Minimum IFG delay (960 nsec between frames) Connections - Per-frame specified delays (multiple conditions) • Transition cable is provided - On external trigger • Two IEEE 802.3 compliant Ethernet RJ-45 connectors - Playback delay modes • High density 15-pin D-sub connector for In/Out • Interrupt generation or user-identified frames triggers per port and four bi-directional avionics- level discretes Timing Reference Ordering Information • 64-bit time tag • IRIG-B receiver (AM or TTL/DC) RAF-EC-2P • IRIG-B generator (TTL/DC) AFDX Express Card, dual port interface, RoHS compliant • IRIG-B PPS synchronization with time tag • Software-selectable internal wrap Optional Software Triggering BT-AIL • Wait for external trigger to transmit AFDX traffic analyzer • Output when marked frame is transmitted • Output when error-free packet received BT-AIL-FAN • Output when error packet received AFDX traffic analyzer file analysis Port Parameters • Full Duplex IEEE 802.3 compliant ports • Software-selectable 10/100 Mbps data rates • Software-selectable auto-negotiation • Software-selectable internal wrap Ethernet Frame Reception About GE Fanuc Intelligent Platforms • Ethernet frames transferred to host buffers via DMA GE Fanuc Intelligent Platforms is a leading global provider of embedded computing solutions for a • Min-to-copy capability wide range of industries and applications. Our comprehensive product offering includes many types • High resolution time-tagging with 20 nsec resolution of I/O, single board computers, high performance signal processors, fully integrated, rugged systems • Link level error detection including flat panel displays, plus high speed networking and communications products. The company is headquartered in the U.S. and has design, manufacturing and support offices throughout the world. Whether you’re looking for one of our standard products or a fully custom solution, GE Fanuc Intelligent Platforms has the breadth, experience and 24/7 support to deliver what you need. For more informa- tion, visit www.gefanuc.com. GE Fanuc Intelligent Platforms Additional Resources Information Centers For more information, please visit the GE Fanuc Americas: Intelligent Platforms web site at: 1 800 322 3616 or 1 256 880 0444 Asia Pacific: www.gefanuc.com +81 3 5544 3973 EMEA: Germany: +49 821 5034-0 UK: +44 1327 359444 ©2007 GE Fanuc Intelligent Platforms. All rights reserved. All other brands or names are property of their respective holders. Specifications are subject to change without notice. 12.07 GFA-1039
Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.
GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.
All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.