EMERSON 00475-0005-0005

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 00475-0005-0005
Manufacturer EMERSON
Category Protective Rubber Boot
Price Request Quote
Lead Time Request Quote

Description

Emerson 00475-0005-0005 Protective Rubber Boot with Stand | for 475 Field Communicator

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 00475-0005-0005? We can help you find it at a competitive price!

Datasheet

Download "Emerson- 00375-0015-0002-ds1-895695879.PDF" (1569 KiB)

Extracted Text

Product Data Sheet July 2009 475 Field Communicator 475 Field Communicator  Full-color graphical user interface  Powerful field diagnostics ®  Bluetooth communication  Long-lasting Lithium-Ion power module ®  Universal support for HART TM and FOUNDATION fieldbus devices The 475 Field Communicator is designed to support all HART and FOUNDATION fieldbus devices from all vendors. What you get is the most powerful Introduction handheld available – universal, The 475 Field Communicator builds user upgradeable, intrinsically on the industry-leading technology safe, rugged and reliable. Only of the 375 Field Communicator the 475 Field Communicator can while adding innovative new deliver all this in a single handheld capabilities including color display, communicator. Bluetooth communication, and advanced field diagnostics. www.fieldcommunicator.com Product Data Sheet July 2009 The weight of the 475 Field Communicator is evenly distributed for comfortable one-handed operation in the field. It runs on Windows CE, a robust, real-time operating system. The 475 Field Communicator has plenty of memory to allow for future expansion. It has 32 MB of application memory and 1 GB of memory on its System Card. User Upgradeable Easy Upgrade Keeps Your Communicator Current The 475 Field Communicator is user upgradeable via the Internet. Avoid the time delays of sending your communicator to a service center for upgrades. With the Easy Upgrade option, you can download new device drivers, Designed not only for use on the bench, the 475 Field Communicator also functionality, or licenses directly enables you to do those tasks that just have to be done in the field. to your 475 Field Communicator. Keeping your 475 Field and normal lighting. To make sure Product Description Communicator updated is easy. all conditions are covered, a The 475 Field Communicator is New HART and FOUNDATION multi-level backlight is included, designed to simplify your work in fieldbus devices, as well as allowing bright, crisp display even the field. The intuitive full color functional updates to existing in plant areas with dim light. user interface allows you to devices, are introduced continually The touch screen display and large leverage the same practices for by device vendors. Keeping physical navigation buttons provide both HART and FOUNDATION up-to-date with the required for efficient use both on the bench fieldbus devices. It includes a Device Descriptions (DDs) for all and in the field. larger touch screen than PDAs the devices in your plant can be or Pocket PCs, supports HART a real challenge. The full color graphics capability is versions 5, 6, and 7 (including provided as standard with every With Easy Upgrade, when new ™ WirelessHART ) devices, and 475 Field Communicator. It uses HART and FOUNDATION fieldbus allows you to upgrade your 475 powerful EDDL technology to allow DDs become available, you can Field Communicator onsite using you to read data from field devices simply download them from the the Internet. in a graphical manner. Charts, Internet and upgrade your 475 graphs, gauges, and product See and Feel the Difference Field Communicator. Update at images are just a few of the ways The touch screen display uses your site, within your control, in which important device data can transflective technology, making it when it’s convenient for you. be displayed using the 475 Field easy to read in both bright sunlight Communicator’s color LCD display. Page 2 475 Field Communicator The Easy Upgrade Utility allows you to transfer system software, DDs, and HART device configurations between the 475 Field Communicator and a PC. Connect using IrDA, Bluetooth, or an SD Card Reader. Online Licensing Through Easy Upgrade, you Universal – HART and The Online Licensing capability always have access to the latest FOUNDATION fieldbus provided with Easy Upgrade HART and fieldbus drivers. With With over 1,100 different HART allows you to enable new options the 475 Field Communicator, you and FOUNDATION fieldbus devices for your 475 Field Communicator are guaranteed universal HART available from more than 100 over the Internet. With Online and FOUNDATION fieldbus support manufacturers, the 475 Field Licensing, powerful options like in a single, intrinsically safe Communicator works with all FOUNDATION fieldbus can be added handheld communicator. your devices to positively by simply purchasing the license impact your bottom line. and downloading it directly to your communicator. Device Configuration Tag: PT-105 Manufacturer: Rosemount Model: 3051S Diag 146 Variables Printed on: 5/19/2009 9:06:38 AM Parameter Value Parameter Value Variation Custom S... 100% Lower Sensor Limit 0.00000 2nd Variable Sensor Temperature Lower Trim Point 0.0 3rd Variable Scaled Variable Manufacturer Rosemount Abnormal Situation P... 0x00 Maximum Temperat... 80.002 F Alarm Direction Hi Mean -0.031420 inH20 Analog Output 3,999 mA Mean Change Check 6* Baseline Mean Value... 0.000000 inH20 Mean Change Sensit... Medium Baseline Standard D... 0.000000 inH20 Mean Chg Action Alert Burst Mode Off Mean Custom Sens... 100% Burst Option Unknown Enumerato... Mean Lower Thresh... 0.000000 inH20 Calibration Type Diff (DP) Mean Upper Thresh... 0.000000 inH20 Cutoff Mode Off Measurement Diff (DP) 0.90 s MISSING CAP Damping Message Damping 0.00 s Min Span 4.5 Date 02/14/2008 Min Span 0.00000 Descriptor PRODUCTION XMT... Min Span 0.0 Dev flags 0x00 Mode Off Device Status 0x50 Model 3051S Diag Diaphragm Material None Model Number I 1 Distributor Rosemount Model Number II 2 Drain Vent Matl 316 SST Model Number III 3 Electronics HW Rev 1 Module Config Std coplanar (C) Electronics S/N 407 Module Range 3 Electronics SW Rev 5 No Label Available 0x00 Fact trm recal loc Sensor trim Num req preams 5 Field Device Rev 1 Number None Easily store and print device configurations for analysis and documentation requirements. Page 3 (()) ( ) Product Data Sheet July 2009 The 475 Field Communicator, with its handy carrying case, provides a single tool for configuring and diagnosing HART and FOUNDATION fieldbus devices. the build up of static electrical Intrinsically Safe Rugged and Reliable energy. The 475 Field Communicator It’s called “Field Communicator” The 475 Field Communicator is meets the Intrinsic Safety for a reason. Some tasks just designed, manufactured, and requirements of the listed have to be performed at the tested to very demanding regulatory agencies and device in the field. The 475 Field specifications. It is ready to go standards. All of the available Communicator is designed for wherever you need to go to get Hazardous Locations approvals tough use in your plant or mill. the job done. are provided in a single model Its large keys and physical option (see Ordering Information). navigation buttons allow for – CENELEC/ATEX one-handed operation, even with – Factory Mutual (FM) your work gloves on. The rugged – Canadian Standards display is designed to take the Association (CSA) knocks and shocks from normal – FISCO use in the plant. – IECEx The 475 Field Communicator’s Protective Rubber Boot provides The protective rubber boot provides added protection in the field and added protection in the field. in your toolbox. Both the rubber ATEX boot and 475 housing are Even the power module is designed in accordance with approved for installation in Intrinsic Safety standards to limit hazardous areas. Page 4 475 Field Communicator configurations in your Powerful Diagnostics document, and troubleshoot communicator or transfer them HART, FOUNDATION fieldbus, Interface with AMS to AMS Device Manager. and WirelessHART devices. Device Manager Together, the 475 Field The 475 Field Communicator is Communicator and AMS Device fully compatible with AMS Device Manager enable you to efficiently Manager, the industry standard for manage all of your devices. asset management software. In fact, Control Magazine readers have Device Configuration selected AMS Device Manager as Transfer device configuration data Management the #1 Calibration Software package to AMS Device Manager via the Using the Easy Upgrade Utility, for over 10 years in a row. IrDA port or Bluetooth interface on you can back up hundreds of your 475 Field Communicator device configurations and can AMS Device Manager uses the and PC. Take your 475 Field transfer them between your intelligence from field devices to Communicator out to the field to communicator and a PC. This create a predictive maintenance configure or update one or more library of device configurations is environment. AMS Device Manager devices. Save up to 1,000 device easy to view and print for analysis. allows you to configure, calibrate, Page 5 Product Data Sheet July 2009 Diagnose Network Problems Detect power supply problems by The 475 Field Communicator monitoring low frequency noise can be used to configure all the on a segment. Locate incorrect FOUNDATION fieldbus devices terminations and faulty devices by in your plant. Use it to perform diagnosing the communications diagnostics for effective start-up signal level. and troubleshooting of fieldbus For HART loops, the 475 Field segments. Create a quality Communicator allows you to segment by diagnosing the verify whether the DC voltage network DC voltage and in the loop is correct. average noise. Specifications PROCESSOR AND MEMORY POWER SUPPLY / CHARGER ENVIRONMENTAL Microprocessor Battery Usage ®    80 MHz Hitachi SH3 Rechargeable Lithium-Ion power module -10° C (14° F ) to +50° C (122° F )  0% to 95% RH (non-condensing) Memory Internal Flash Battery Operating Time for 0° C (32°F ) to +50° C (122° F )   32 MB 20 hours – continuous use  40 hours – typical use Charge System Card   80 hours – standby mode 10° C (32° F ) to +40° C (104° F)  1 GB secure digital card Battery Charger Options Storage With Batteries RAM   Input voltage 100-240 VAC, 50-60 Hz -20° C (-4° F ) to +55° C (131° F )  32 MB  Cables included with U.S., Europe, Storage Without Batteries and U.K. plugs  -20° C (-4° F ) to +60° C (140° F) PHYSICAL CONNECTION Enclosure Rating Weight  IP51 (from front)  Approximately 1.65 lb. (0.75kg) Battery Charger with battery Shock  Mini DIN 6-pin jack  Tested to survive a 1-meter Display HART and Fieldbus drop test onto concrete  1/4 VGA (240 by 320 pixels)  Three 4mm banana plugs (one common color, 3.5 in. (8.9 cm) transflective to HART and FOUNDATION fieldbus) EASY UPGRADE REQUIREMENTS display with touch screen  IrDA Port Usage Anti-glare coated   IrDA (Infrared Data Access) port PC with Internet access Keypad  supporting up to 115 Kbps CD Rom drive  25 keys including 4 action keys,   ±15 degrees recommended maximum IrDA port (or adapter) or 12 alphanumeric keys, tab key, angle from center line Bluetooth (or adapter) function key, backlight key, power key,   Approximately 18 in. (45.7 cm) SD Card Reader (required for some and 4 cursor-control (arrow) keys; recommended maximum distance upgrades) membrane design with tactile feedback  Windows XP (SP2 or SP3) or Bluetooth Windows Vista Business (SP1)  Up to 32.8 ft. (10 m) communication distance  Uses standard Windows drivers  FCC, IC, and CE approvals Page 6 475 Field Communicator 475 Field Communicator Spare Parts List Description Part Number Ruggedized 250 Ohm Load Resistor 00275-0096-0001 Rechargeable Lithium-Ion Power Module 00475-0002-0022 Power Supply & Charger (Li-ion/NiMH) US/UK/EU connection types included 00475-0003-0022 Power Supply/Charger Standard Cord Set (US/UK/EU cords) 00475-0003-0002 Power Supply/Charger Australia (AU) cord 00475-0003-0003 Leadset with connectors 00375-0004-0001 Mounting Straps 00475-0005-0002 Carrying Case (with straps) 00475-0005-0003 Magnetic Hangar 00475-0005-0004 Protective Rubber Boot 00475-0005-0005 Stylus (pack of 2) 00475-0006-0001 (1) IrDA to USB Adapter 00375-0015-0002 (2) System Card (SD) Reader (with USB Interface) 00375-0018-0022 (1) Bluetooth Adapter 00475-0018-0023 Stand 00475-0044-0001 Getting Started Guide 00475-0045-3001 Resource CD 00475-0049-0001 (4) Online Licensing FOUNDATION fieldbus License Via Web 00375-0142-0002 (3) Easy Upgrade (New) License via Web 00375-0142-0003 (3) (5) Easy Upgrade (ReNew) License via Web 00375-0142-2003 (6) AMS Device Manager Handheld Interface Kit AMS Device Manager Field Communicator Interface Kit (25 tags) AW7005HC00025 AMS Device Manager Field Communicator Interface Kit (100 Tags and above) AW7005HC20000 (1) Can be used to support communication between the 475 and the Easy Upgrade Programming Utility or AMS Device Manager (with Handheld Communicator Interface Kit. IrDA or Bluetooth communication is required to register the 475 and use the Online Licensing system. (2) The System Card (SD) Reader allows a user to upgrade a System Card much faster than when using IrDA or Bluetooth. Due to file size constraints, major upgrades require the use of a card reader. (3) The Easy Upgrade feature allows users to add new System Application software and Device Descriptions (DDs) to the 475 for a period of 3 years. To upgrade without this feature, the System Card must be sent to a Service Center and the upgrade will be completed for a fee. (4) The Field Communicator Online Licensing system is available to end users but it may also be performed by an agent on the user's behalf. It is at the agent's discretion if an additional fee should apply. Any order must be accompanied by the System Card S/N. Instant notification available licenses for download can be provided to email addresses provided at time of order. For more details, see the Online Licensing procedure at www.fieldcommunicator.com (5) The ReNew option is available on System Cards where the Easy Upgrade license has been expired for less than 90 days. Date of expiration can be obtained by inter facing the 475 with v1.6.0 (or higher) of the Easy Upgrade Programming Utility. (6) Requires AMS Device Manager (v6.2 or higher). Both AMS Device Manager and the Handheld Communicator Interface Kit are available for sale through select channels only. See www.assetweb.com for more details. Page 7 Product Data Sheet May 2009 475 Field Communicator 475 Field Communicator Ordering Information Model Product Description (1) 475 Field Communicator Code Communication Protocol H HART (2) F HART and FOUNDATION fieldbus Code Battery Type P Rechargeable Lithium-Ion Power Module Code Power Supply/Charger (3) 1 Power Supply and Charger NiMH/Li-Ion (US/UK/EU connection types included) (4) 9 Not included Code Language E English D German J Japanese R Russian Code Product Certifications KL ATEX, FM, CSA and IECEx Intrinsically Safe (includes FISCO as applicable) NA No Approval Code Easy Upgrade (5) U Easy Upgrade (3 year) Option 9 Not Included Code Standard Options (6) GM Graphics (included at No Charge) (7) Device Configuration Management (included at No Charge) Code Bluetooth (8) T Bluetooth Communication 9 No Bluetooth Communication Code Options (9) A Spare Rechargeable Lithium-Ion Power Module S Protective Rubber Boot with Stand Typical HART Model Number: 475 H P 1 E KL U GMT Typical HART/Fieldbus Model Number: 475 F P 1 E KL U GMT (1) Base Model 475 includes Field Communicator unit with Color LCD display, System Card, leadset with connectors, carrying case, Getting Started Guide, Resource CD, stylus, and straps. (2) Must specify Easy Upgrade Option (Code U) when ordering this model option. (3) To obtain an Australia power cord, order part number 00375-0003-0003. (4) This option should only be considered if the user already has a 375 or 475 Power Supply/Charger. If it is a 375 Power Supply / Charger, it must be the Li-Ion/NiMH version. (5) The Easy Upgrade capability allows users to add new System Application software and Device Descriptions (DDs) to the 475 for a period of 3 years. To upgrade without this feature, the System Card would have to be sent to a Service Center. (6) The Graphics functionality enables a user to access enhanced grapical features when using the HART or FOUNDATION fieldbus application. (7) Device Configuration Management provides the capablity to store in excess of 1,000 configurations and print them. (8) Bluetooth enables communication to a PC via the Bluetooth protocol. (9) A fully charged Lithium-Ion Power Module is capable of delivering power for 20 hours of typical field use. If requirements exceed this specification, a Spare Power Module (code A) should be specified. ©2009, Emerson Process Management. Emerson Process Management The contents of this publication are presented for informational purposes only, and while every effort has Asset Optimization Division been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express 12001 Technology Drive or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the Eden Prairie, MN 55344 USA right to modify or improve the designs or specifications of our products at any time without notice. T 1(952) 828-3206 All rights reserved. AMS is a mark of one of the Emerson Process Management group of companies. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the F 1(952) 828-3006 property of their respective owners.

Related Products

None available

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.04 seconds.