BOSER MPI-815H
Specifications
Altitude
0~10,000ft
Dimensions
19.8 x 9.7 x 4.0 cm
Efficiency
The efficiency is higher than 70% while measuring at nominal line and rated load
EMI
FCC docket 20780 curve B / EN55022B
EMS
IEC-61000-4-2 Level 3 8KV air discharge, Level 2 4KV contact discharge / IEC 61000-4-3 Level 3 10V/M / IEC 61000-4-4 Level 3 2KV / IEC 61000-4-5 Level 3 2KV / IEC61000-4-6 Level 3 10V / IEC 61000-4-8 Level 3 10A/M / IEC 61000-4-11
Hold Up Time
The hold up time is longer than 16mS at 115VAC input and rated load
Humidity
10~90% non-condensing
Input Current
2A at 115VAC or 1.5A at 230VAC max.
Input Frequency
47~63Hz
Input Voltage
85~264VAC
Inrush Current
The maximum inrush current is 6A at 115VAC or 3A at 230VAC
Line Regulation
The line regulation is less than +/-1% at rated load with +/-10% change in input voltage
Load Range
At the factory, the +5V output is set between 5.08~5.13V and all output at 60% rated load, and the other output is checked to be within the accuracy range. The maximum total combined output power on the 3.3V and 5V rails is 90W. The maximum load cannot be exceed 150W
Load Regulation
The load regulation for +5V is less than +/-2%, for +12V is less than +/-5%, for +3.3 and -12V is less than +/-5% while the measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output is at 60% rated load
Over Temp. Protection
When the power supply operating over the temperature limit, the power supply will be shut down automatically to protect itself
PFC
IEC 61000-3-2 / IEC 61000-3-3
Power Fail Signal
The pwoer fail signal will go low at least 1ms before any of the output voltages fall below the regulation limits
Power Good Signal
The power is turned on, the power good signal will go high between 100ms to 500ms after all output DC voltage are within regulation limits
Power On/Off
The power supply will be turned on when the power On/Off pin is connected to secondary GND
Protection
The power supply will generate the hiccup mode to protect itself against short circuit or over load condition, and will return to normal after wrong condition is removed. The power supply has over voltage protection function
Ripple And Noise
The peak to peak ripple and noise for +5V, 3.3V output are less 50mV for +5Vsb for +5Vsb is 100mV, for +12V is less than 100mV, for -12V is less than 150mV at ranted load and nominal input, which is measured by a 15MHz bandwidth limited oscilloscope and the each output is connected with a 0.47uF capacitor
Safety
UL 60950 / CSA 22.2 No. 234 / VDE EN60950
Temperature
0~+50°C (operating); -20~+70°C (storage)
Datasheet
Extracted Text
Power Supply MPI-815H 150W Switching Power Supply with PFC Specifications * Input Voltage: 85~264VAC * Input Frequency: 47~63Hz * Inrush Current: The maximum inrush current is 6A at 115VAC or 3A at 230VAC * Load Range: At the factory, the +5V output is set between 5.08~5.13V and all output at 60% rated load, and the other output is checked to be within the accuracy range. The maximum total combined output power on the 3.3V and 5V rails is 90W. The maximum load cannot be exceed 150W * Ripple And Noise: The peak to peak ripple and noise for +5V , 3.3V output are less than 50mV for +5Vsb is 100mV , for +12 V is less than 100mV, for -12V is less than 150mV at ranted load and nominal input, which is measured by a 15MHz bandwidth limited oscilloscope and the each output is connected with a 0.47uF capacitor * Line Regulation: The line regulation is less than +/-1% at rated load with +/-10% change in input voltage * Load Regulation: The load regulation for +5V is less than +/-2 %, for +12V is less than +/-5%, for +3.3 and -12V is less than +/-5% while the measuring is done by changing the measured output Output Min. Rated Max. Voltage loading +/-40% from 60% rated load, and keep other output is at Voltage Load Load Load Accuracy 60% rated load +5V 1A 11A 14A 5.05~5.15V * Hold Up Time: The hold up time is longer than 16mS at 115VAC +12V 0A 5A 10A 11.6~12.6V input and rated load -12V 0A 0.5A 1A -11.4~-12.6V +3.3V 0A 7.5A 12A 3.2~3.4V * Power On/Off: The power supply will be turned on when the power +5Vsb 0A 0.75A 1.5A 4.8~5.2V On/Off pin is connected to secondary GND * Power Good Signal: The power is turned on, the power good signal will go high between 100 mS to 500 mS after all output DC voltage are within regulation limits * Power Fail Signal: The power fail signal will go low at least 1ms before any of the output voltages fall below the regulation limits Safety Standards * Efficiency: The efficiency is higher than 70% while measuring at * Safety: UL 60950, CSA 22.2 NO. 234, VDE EN 60950 nominal line and rated load * EMI: FCC docket 20780 curve "B", EN 55022 "B" * EMS: IEC 61000-4-2 Level 3 8KV air discharge, Level 2 4KV * Altitude: Will operate properly at any altitude between 0 to 10000ft contact discharge / IEC 61000-4-3 Level 3 10V/M / IEC 61000-4- * Protection: The power supply will generate the hiccup mode to 4 Level 3 2KV / IEC 61000-4-5 Level 3 2KV / IEC 61000-4-6 protect itself against short circuit or over load condition, and will Level 3 10V / IEC 61000-4-8 Level 3 10A/M / IEC 61000-4-11 * PFC: IEC 61000-3-2, IEC 61000-3-3 return to normal after wrong condition is removed. The power supply has over voltage protection function * Over Temp. Protection: When the power supply operating over the temperature limit, the power supply will be shut down automatically to protect itself o o * Temperature: 0~50 C (operating); -20~+70 C (storage) * Humidity: 10~90% non-condensing * Dimensions: 19.8 x 9.7 x 4.0 cm
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the MPI-815H?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods