Industrial Trading chervon right Manufacturers chervon right A chervon right ARCOM chervon right PCRELAY8/IN8
About product Features Datasheet FAQ

ARCOM PCRELAY8/IN8

Image of ARCOM PCRELAY8/IN8

Description

Arcom PCRELAY8/IN8 Digital I/O 8 Changeover Relay Outputs and 8 Opto-Isolated Digital Inputs (+5/+55°C Operating Temperature)

Part Number

PCRELAY8/IN8

Price

Request Quote

Manufacturer

ARCOM

Lead Time

Request Quote

Category

Digital I/O

Features

Datasheet

pdf file

Arcom-PCRELAY8-IN8-Digital-IO-Relay-datasheet1-1215208103.pdf

206 KiB

Extracted Text

2192-09458-000-000 PCRELAY8/IN8 8-bit ISA add-on Board Preface Packing List This product is shipped as follows: � Board � User Manual � Utility Disk � PCbus Library Datasheet If any of the above appear to be missing, please telephone Arcom on 01223 411 200. Utility Disk This product is shipped with a Utility Disk which contains: � PCbus Library Manual � Source Code for all PCbus I/O boards � A test program called EXAMP-01.EXE Handling This board contains CMOS devices which could be damaged in the event of static electricity being discharged through them. At all times please observe anti-static precautions when handling the board and always unpack and install the board in an anti-static working area. Please ensure that should a board need to be returned to Arcom, it is adequately packed and if a battery is fitted, that it is isolated. Product Information Fax x-on-D Demand Sy ystem Full information about other Arcom products is available via the , (Telephone Numbers are listed below), or by contacting our W WebS Site in the UK at: w ww ww.arcom.co.u uk k. Useful C Co ont ta act Inf fo or rmatio on Customer Support Sales or for the US: E-mail Tel: +44 (0)1223 412 428 Tel: +44 (0)1223 411 200 icpsales@arcomcontrols.com Fax: +44 (0)1223 403 400 Fax: +44 (0)1223 410 457 E-mail: support@arcom.co.uk E-mail: sales@arcom.co.uk Uni ited K Kingdom United St tates France Germany I It taly Arcom Control Systems Ltd Arcom Control Systems Inc Arcom Control Systems Kostenlose Infoline: Numero Verde: Clifton Road 13510 South Oak Street Centre d�affaires SCALDY Tel: 0130 824 511 Tel: 1677 80841 Cambridge CB1 4WH, UK Kansas City MO 64145 USA 23 rue Colbert Fax: 0130 824 512 Fax: 1677 90841 Tel: 01223 411 200 Tel: 816 941 7025 7885 SAINT QUENTIN FoD: 0130 860 449 FoD: 1678 73600 Fax: 01223 410 457 Fax: 816 941 0343 Cedex, FRANCE Netherla ands B Belg gi ium FoD: 01223 240 600 FoD: 800 747 1097 Tel: 800 90 84 06 Gratis 0800 Nummer: Groen Nummer: Fax: 800 90 84 12 Tel: 0800 0221136 Tel: 0800 7 3192 FoD: 800 90 23 80 Fax: 0800 0221148 Fax: 0800 7 3191 Whilst Arcom�s sales team is always available to assist you in making your decision, the final choice of boards or systems is solely and wholly the responsibility of the buyer. Arcom�s entire liability in respect of the boards or systems is as set out in Arcom�s standard terms and conditions of sale. If you intend to write your own low level software, you can start with the source code on the disk which is supplied. This is example code only to illustrate use on Arcom�s products. It has not been commercially tested. No warranty is made in respect of this code and Arcom shall incur no liability whatsoever or howsoever arising from any use made of the code. ' 1997 Arcom Control Systems Ltd. Arcom Control Systems is a subsidiary of Fairey Group Plc. All trademarks recognised. Arcom Control Systems Ltd operate a company-wide quality management system which has been certified by the British Standards Institution (BSI) as compliant with ISO9001:1994 Page 1 2192-09458-000-000 J553 PCRELAY8/IN8 Introduction The PCRELAY8/IN8 is an 8-bit ISA bus add-on board providing 8 changeover relays. The power switching rating is 60W (resistive load). This allows supplies upto 48v DC and switching currents 1.0A. There are also 8 opto-isolated inputs providing an input to output isolation of 1500v. Features � CE compliant design � 8 changeover relays with a power switching rating of 60W (resistive load) � Switching voltage up to 48v DC and switching currents up to 1.0A � 8 opto-isolated inputs complete with two current limiting resistors per input � Opto-input switching voltage: 10v to 30v � Output status readback register � Occupies 4 Bytes of Address Space � Relay drivers disabled on power-up and reset � Both normally closed and normally open relay terminals are available at the I/O connector � Link selectable debounce option on inputs � Link selectable, even boundary base address � Board access LED � Operating temperature range, +5�C to 55�C � Power consumption +5V –0.25V 250mA typical + 40mA per relay operating � Relay life rating 500,000 operations minimum (DC full load) Getting Started � Switch off PC � Install board in supplied configuration � Switch on PC � Run EXAMP-01.EXE (supplied on the utility disk) � An access/user LED should flash. If not check default link configuration (Page 5) Operation Each relay is switched by writing a �1� to the relay output register. On power-up or reset the output latches that drive the relay drivers are disabled. To enable them it is necessary to write �01� to base address +1. For system initialisation, it is recommended that the output register is written with the required relay states before the relay relay enable bit is set. The status of the opto inputs is read form I/O address base +1. When an input channel is switched on the value read by the host will be a �0�. Page 2 J553 PCRELAY8/IN8 2192-09458-000-000 I/O Map Address Offset Register name Read/Write Comments 00 Relay output W Write to relays 0/7 00 Relay status R Readback from relay drivers 01 Relay enable W Enable relay driver latches 01 Opto-inputs R Read Opto-inputs 0/7 Bit function Relay outputs Bit 0-7 for relay 0-7 ‘0’ = relay NC contacts closed ‘1’ = relay NO contacts closed Relay status Bit 0-7 ‘0’ = relay NC position ‘1’ = relay NO position Relay enable Bit 0 ‘0’ = all relays off (NC position) ‘1’ = relays controlled by relay output register Opto inputs Bit 0-7 ‘0’ = input ON ‘1’ = input OFF Links Address Selection LK1 The base address of this board is set using LK1; inserting a jumper selects �1�. A9 A8 A7 A6 A5 A4 A3 A2 Debounce Option LK2 Link Position Data bit A 0 B 1 C 2 D 3 E 4 F 5 G 6 H 7 Page 3 2192-09458-000-000 J553 PCRELAY8/IN8 Default Link Position [Default address 180h] User Configuration Record Output Connector PL1 pin assignments DType Ribbon Cable Function Ribbon Cable Function DType 1 1 Not connected 2 Relay 1 common 34 18 3 Relay 1 NO 4 Relay 1 NC 2 35 5 Not connected 6 Not connected 19 3 7 Relay 2 common 8 Relay 2 NO 36 20 9 Relay 2 NC 10 Not connected 4 37 11 Not connected 12 Relay 3 common 21 5 13 Relay 3 NO 14 Relay 3 NC 38 22 15 Not connected 16 Not connected 6 39 17 Relay 4 common 18 Relay 4 NO 23 7 19 Relay 4 NC 20 Not connected 40 24 21 Not connected 22 Relay 5 common 8 41 23 Relay 5 NO 24 Relay 5 NC 25 9 25 Not connected 26 Not connected 42 26 27 Relay 6 common 28 Relay 6 NO 10 43 29 Relay 6 NC 30 Not Connected 27 11 31 Not connected 32 Relay 7 common 44 28 33 Relay 7 NO 34 Relay 7 NC 12 45 35 Not connected 36 Not connected 29 13 37 Relay 8 common 38 Relay 8 NO 46 30 39 Relay 8 NC 40 Not connected 14 47 41 common -ve input (low bits) 42 +ve input bit 0 31 15 43 +ve input bit 1 44 +ve input bit 2 48 32 45 +ve input bit 3 46 +ve input bit 4 16 49 47 +ve input bit 5 48 +ve input bit 6 33 17 49 +ve input bit 7 50 common -ve input (high bits) 50 Page 4 J553 PCRELAY8/IN8 2192-09458-000-000 Installation for CE Compliance To maintain compliance with the requirements of the EMC directive (89/336/EEC), this product must be correctly installed. The PC in which the board is housed must be CE compliant as declared by the PC manufacturer. The type of external I/O cable can be chosen according to the notes below: 1. Remove the cover of the PC observing any additional instructions of the PC manufacturer. 2. Locate the board in a spare ISA slot and press gently but firmly into place. 3. Ensure that the metal bracket attached to the board is fully seated. 4. Fit the bracket clamping screw and firmly tighten this on the bracket. Note: Good contact of the bracket to the chassis is essential. 5. Replace the cover of the PC observing any additional instructions of the PC manufacturer. Cable Cable length 1 Metre or less : Ribbon cable satisfactory Cable 1M to 3M : Commercial screened cable gives the protection required Longer cable or noisy environment : Use fully screened cable with metal backshells e.g. Arcom CAB50CE The following standards have been applied to this product: BS EN50081-1: 1992 Generic Emissions Standard, Residential, Commercial, Light Industry BS EN50082-1: 1992 Generic Immunity Standard, Residential, Commercial, Light Industry BSEN55022: 1995 ITE Emissions, Class B, Limits and Methods Page 5 2192-09458-000-000 J553 PCRELAY8/IN8 Page 6 J553 PCRELAY8/IN8 2192-09458-000-000 Page 7 2192-09458-000-000 J553 PCRELAY8/IN8 Revision History Manual PCB Comments Issue A V1 I1 960927 First full release of Manual. Issue B V1 I2 961129 [ECO2359,2370] Issue C V1 I3 970124 [ECO2458] Issue D V1 I3 970207 [ECO2465] Issue E V1 I3 970326 [ECO2493] Issue F V1 I3 980127 [ECO2684] Issue G V1 I3 980707 [ECO2748] Page 8

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the PCRELAY8/IN8?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Arcom AIM104-IO32 32 TTL PC/104 Compatible Digital I/O

product

32 TTL compatible digital I/O

product

Arcom AIM104-RELAY8/IN8 PC/104 Module. 8 Changeover Relays | 8 Opto-isolated Inputs

product

Arcom AIM104-RELAY8/IN8-R 8 Changeover Relays and 8 Opto-isolated Inputs Single Board Computer

product

Arcom APCI-ADADIO Multi-Function 12-bit ADC and DAC, with Digital I/O & CTC

product

Arcom APCI-IB40 40-Channel Digital I/O & Counter Board