Industrial Trading chervon right Manufacturers chervon right A chervon right ADTRAN chervon right 61230001L1-22A
About product Features Datasheet FAQ

ADTRAN 61230001L1-22A

Image of ADTRAN 61230001L1-22A

Description

Adtran 61230001L1-22A Express 6540 SHDSL 2W/4W NTU AC Power

Part Number

61230001L1-22A

Price

Request Quote

Manufacturer

ADTRAN

Lead Time

Request Quote

Category

Interface Module

Features

Datasheet

pdf file

EXPRESS 6540 SHDSL 2W-4W NTU.pdf

103 KiB

Extracted Text

6540 SHDSL 2w4w NTU, AC Powered 61230001L1-22A 0406 Nx64K X.21 100-240VAC 50/60Hz 100mA V.35/V.36 SHDSL G.703 CONTROL V.28 Express 6500 Series 6540 Rear Panel 6540 Front Panel LED Indicator Functionality DESCRIPTION ® The ADTRAN 6540 SHDSL 2w4w NTU (P/N 1230001L1) functions as an interface between the LED Off Green Yellow Red SHDSL network and the Data Terminal Equipment for applications such as LAN-to-LAN bridging, SHDSL Unit is powered off Port is trained; no Port is trained with Port is attempting/is 1 2 Frame Relay circuit, and PABX termination. The NTU operates in two different system configurations: active alarms minor active alarm trained with major alarm ® G.703 Port is not active Port is active with no Port is active with a Port is active with a major ♦ as a remote unit to the ADTRAN Total Access 3000 multiservice platform 3 4 active alarm minor alarm alarm ♦ in pairs in a point-to-point limited distance campus configuration, with one NTU configured to “LT” Nx64K Port is not active. Port is active with no N/A Port is active with an mode 5 active alarm active alarm condition . RTS/C Nx64K port is not active V.35/V.36 'Request To N/A N/A FEATURES or when active, V.35/V.36 Send' or X.21 'Control' 'Request To Send' or X.21 line from the DTE is The 6540 SHDSL 2w4w NTU is housed in a stand-alone plastic case having the features listed below: 'Control' line from the ON. ♦ four recessed pushbuttons, on the front panel, described in the table below DTE is OFF. ♦ eight LED indicators, on the front panel, described in the table below RLSD/I Nx64K port is inactive or V.35/V.36 'Receive N/A N/A ♦ SHDSL, G.703 and/or Nx64K ports, local management port, and local power AC connection on the when active, V.35/V.36 Line Signal Detector' rear panel 'Receive Line Signal or X.21 'Indication' Detector' and X.21 control line from the 'Indication' control line NTU (DCE) is ON. Pushbutton Functionality from the NTU is OFF. Pushbutton Description LLOOP No Local Loop is active. N/A A Local Loopback is A Local Loop is active on PORT SELECT Pressing the SELECT button will sequentially select active ports in the following order: Nx64k active on the selected one or more ports or port, G.703 port, SHDSL port, and then cycle back to “No Port.” port. services (when no port is LOCAL LOOP/ If a port is selected, and a BERT (Bit Error Rate Test) is not in progress, then pressing the selected). ERR INJ button will initiate/terminate a local loop on the selected port. If a BERT is in progress, then RLOOP No Remote Loop is N/A A Remote Loopback is A Remote Loop is active pressing the button injects a single bit error. active. active on the selected on one or more ports or port (when determined services (when no port is REMOTE LOOP If the SHDSL port is selected, then pressing the button either places or removes a remote loop via established EOC) selected). on the port by sending a EOC request message to the LTU (or NTU in campus mode). If the BERT BERT is not active. A BERT is active, and A BERT is active, and BERT is active, but the Nx64K port or G.703 port (with only one service defined) is selected, then pressing the button the test pattern detector one or more test pattern test pattern detector is not will place or remove a remote loop on the selected port's single data service by sending is synchronized with bit errors have been synchronized. respective inband loop up or loop down patterns to the far end (in the associated data service no received bit errors. received. timeslots). 1 Minor SHDSL port alarms are CRC errors, Loop Attenuation Threshold Alarm, SNR Margin Threshold Alarm, Segment BERT If a port is selected, and there are no local loops, then pressing the button starts or stop a BERT Anomaly, and any ES, SES, UAS, CVC, and LOSWS 15-Minute Threshold Alarm. on the selected port. 2 Major SHDSL port alarms are LOS, LOSW, or Segment Defect. 3 Minor G.703 port alarms are Rx RAI, Frame Slip, CRC-4 errors, LBER, and any ES, SES, UAS, and CVC 15-Minute Threshold Alarm. COMPLIANCE 4 Major G.703 port alarms are LOS, LOF, LOMF, Rx AIS, or HBER. EN 300 386-2; IEC 60950/EN 60950/AS NZS60950; S016; S043.2; ITU K.21 Enhanced; Telstra 1555 5 Nx64K port alarms are Clock Slip, Loss of External Clock, FIFO Underflow/Overflow, and Inactivity Alarm. A complete Installation and Maintenance Practice (P/N 61230001L1-5) can be found at www.adtran.com. Enter the desired P/N in the search field. PRICING AND AVAILABILITY 800.827.0807 TECH SUPPORT 800.726.8663 6540 SHDSL 2w4w NTU, AC Powered RETURN FOR REPAIR 256.963.8722 www.adtran.com 61230001L1-22A Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. U.S. and Canada customer Faxback: 877-457-5007, Document 414. 1. NT 1. Unit Mode 1. LTU 2. LT 2. Cross-Connect Map 1. Unit Information 1. 2-Wire 2. NTU 1. Internal Clock 1. Interface Mode 3. Clock Source 2. 4-Wire Main Menu 2. Nx64 ETC(113)/X 1. Unit Options 4. Circuit ID 2. Payload Rate (kbps) * 3. G.703 Rx Clock 0. Disabled 4. SHDSL Rx Clock 5. Date and Time 3. SNR Margin Alarm Threshold (dB) 1-15. Alarm Threshold 6. Restore Factory Defaults 0. Disabled 4. Loop Attenuation Alarm Threshold (dB) 7. Upgrade Firmware 1-127. Alarm Threshold 1. Disabled 1. Disabled 8. Local Management 5. Outage Auto-Retrain 2. Enabled 2. Enabled 9. Change Password 0. Disabled 1. ES 15-Minute Alarm Threshold 2. SHDSL Options 6. PM Thresholds 1-900. Seconds 2. Provisioning 0. Disabled 1. Disabled 2. SES 15-Minute Alarm Threshold 1. ISDN-PRA V3 1-900. Seconds 2. Enabled 0. Disabled 1. Disabled 3. UAS 15-Minute Alarm Threshold 2. G.704 CRC-4 Multiframing 1-900. Seconds 2. Enabled 0. Disabled 3. Timeslot Idle Pattern 4. CVC 15-Minute Alarm Threshold 3. G.703 Options 00h to FFh 1-65535. Seconds 1. Disabled 0. Disabled 4. Spare Bits Insertion to Span 5. LOSWS 15-Minute Alarm Threshold 2. Enabled 1-900. Seconds 00h to FFh 0. Disabled 5. Spare Bits Pattern to Span 6. OS 15-Minute Alarm Threshold 1-900. Seconds 1. Disabled 6. Spare Bits Insertion 2. Enabled 1. Disabled 00h to FFh 1. Interface Type Auto Detection 7. Spare Bits Pattern 1. Disabled 2. Enabled 1. X.21 2. Enabled 8. RAI Generation 2. Interface Type Manual Select 2. V.35 1. Disabled 9. E-bit Generation 0. Disabled 3. V.36 0. Disabled 2. Enabled 3. Inactivity Alarm Delay (Secs) 1-900. Seconds 1-100. Alarm Threshold 10. ES 15-Minute Alarm Threshold 1. From DCE, TC (Circuit 114) 0. Disabled 1. Normal 4. Tx Clock Source 11. SES 15-Minute Alarm Threshold 2. From DTE, ETC (Circuit 113) 1-900. Seconds 2. Inverted 5. Tx Clock Polarity 0. Disabled 3. Auto 1. Permanent On 12. UAS 15 Minute Alarm Threshold 6. X.21 C Mode 1-900. Seconds 2. DTE Driven 1. Permanent On 7. X.21 I Mode 0. Disabled 2. Sync Mode 13. CVC 15-Minute Alarm Threshold 1-65535. Seconds 1. Permanent On 8. V.35/V.36 RTS (Circuit 105) 4. Nx64K Options 2. DTE Driven 1. Permanent Off 9. V.35/V.36 CTS (Circuit 106) 2. Permanent On 3. RTS Driven 0 to 255 = Delay in ms 10. V.35/V.36 RTS to CTS Delay (ms) 1. Permanent Off 11. V.35/V.36 DSR (Circuit 107) 2. Permanent On 1. Permanent On 12. V.35/V.36 DTR (Circuit 108/2) 1. Permanent Off 2. DTE Driven 2. Permanent On 13. V.35/V.36 RLSD (Circuit 109) 3. Sync Mode 1. Dual Sided 2. Transparent 1. Loopback Types 3. Nontransparent 5. Test Options 1. PN127 1. In-band Loopback Protocol 2. V.54 1. SHDSL Port 1. Disabled 2. G.703 Port 2. Inband Loopback Options 2. G.703 Services In-band Pattern Detection 2. Enabled 3. G.703 Services 3. Status 4. Nx64K Port 1. Disabled 3. Nx64k In-band Pattern Detection 2. Enabled 5. Reset All Status 1. SHDSL Local Loopback 0. Disabled 3. Loopback Timeout (Min) 2. SHDSL Remote Loopback 1-999. Time out in Minutes 1. ALT 4. Test 3. SHDSL BERT 2. 2047 1. Dual Sided 4. BERT Pattern 4. G.703 Local Loopback 3. 2E15-1 2. Customer Transparent 5. G.703 BERT 4. QRSS 3. Customer Non-Transparent 1. Normal 1. Local Loopback 5. BERT Pattern Polarity 6. G.703 Services 4. Network Transparent 2. Inverted 2. Remote Inband Loopback 1. Disabled 6. Pushbuttons (All) 5. Network Non-Transparent 3. BERT 2. Enabled 1. Disabled 7. SHDSL Port Select Pushbutton 2. Enabled 1. Permanent Off 8. V.35/V.36 RL (Circuit 140) 7. Nx64k Local Loopback 2. DTE Driven 1. Permanent Off 8. Nx64k Remote Inband Loopback 9. V.35/V.36 LL (Circuit 141) 2. DTE Driven 9. Nx64k BERT 1. SHDSL Port 1. Permanent Off 10. V.35/V.36 TI (Circuit 142) 2. Test Driven 5. Performance History 2. G.703 Port 3. Reset All Local Management 6. Terminal Mode * 2-wire mode: 192 kbps to 2.304 Mbps (N x 64 kbps, where N=3 to 36) Remote Virtual Terminal Management 4-wire mode: 384 kbps to 4.608 Mbps (N x 64 kbps, where N=even numbers, 6 to 72)

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 61230001L1-22A?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Adtran 1179001L1 Outside Plant Access Terminal Module, Outside plant housing with protectors and IDC...

Adtran 1179001L2 Outside Plant Access Terminal Module, Outside plant housing with protectors and 35 ...

product

ADTRAN 1200861L1 Interface Module - Modem (digital)- plug-in module, 64kbps,

product

ADTRAN 1200868L1 NIM Module - Frame Relay operating mode, internal newtrok, alarm generation and det...

product

ADTRAN 1200872L1 Network Interface Module - Frame Relay operating mode, Network, internal, Test Patt...

product

ADTRAN 1200875L1 Interface Module - Clear channel and bonding mode, T Dial Backup Interface Module