XP POWER JPP130PQ04
Specifications
Cooling
10 CFM
Efficiency
75% typical
Hold Up Time
15 ms min
Initial Set Accuracy
2% except V2: 3%
Input Current
2.10 A at 115 VAC, 1.10 A at 230 VAC
Input Frequency
47-63 Hz
Input Voltage
90-264 VAC
Inrush Current
35 A at 115 VAC, 70 A at 230 VAC
Isolation
3000 VAC Input to Output; 1500 VAC Input to Ground; 500 VAC Output to Ground
Line Regulation
±0.5% max
MTBF
200 kHrs per MIL-STD-217F
Operating Humidity
5-95% RH, non-condensing
Operating Temperature
-10 ºC to +60 ºC, derate from 100% load at +40 ºC to 50% load at +60 ºC
Overvoltage Protection
V1, V2 & V5 only: 112-132% of nominal
Power Density
7.2 W/In3
Power Factor
0.98 typical
Remote sense
On 3.3 V output only; Compensates for up to 0.5 V drop
Ripple & Noise
65 mV for V1, 1% pk-pk on all other outputs, 20 MHz BW
Shock
20 G on 3 axis, 3 times each
Signals
PFD - TTL Level
Start Up Delay
2 s max
Start Up Rise Time
12 ms max
Storage Temperature
-40ºC to + 85ºC
Temperature Coefficient
0.04%/ºC
Transient Response
4% max. deviation, 500 µs recovery time for a 25% load change
Vibration
10-55 Hz, 0.15 at 1 octave/min for 30 mins on each 3 axis
Features
- Active Power Factor Correction
- High Power Density
- Power Fail Signal
- Short Circuit Protection with Auto Recovery
- Small Footprint
- Up to Five DC Outputs
- Wide Adjustment on Two Outputs
Datasheet
Extracted Text
130 Watts xppower.com JPP130 Series • High Power Density • Small Footprint • Up to Five DC Outputs • Wide Adjustment on Two Outputs • Short Circuit Protection with Auto Recovery • Power Fail Signal • Active Power Factor Correction Specification Input General Input Voltage • 90-264 VAC Efficiency • 75% typical Input Frequency • 47-63 Hz Isolation • 3000 VAC Input to Output 1500 VAC Input to Ground Input Current • 2.10 A at 115 VAC, 1.10 A at 230 VAC 500 VAC Output to Ground Inrush Current • 35 A at 115 VAC, 70 A at 230 VAC 3 Power Density • 7.2 W/In Power Factor • 0.98 typical Signals • PFD = TTL Level (see note 5) MTBF • 200 kHrs per MIL-STD-217F Output Output Voltage • See table Environmental Output Voltage Trim • User adjustable (see note 3) Operating Temperature • -10 ºC to +60 ºC, derate from 100% load Initial Set Accuracy • 2% except V2: 3% at +40 ºC to 50% load at +60 ºC Minimum Load • See note 4 Cooling • 10 CFM Start Up Delay • 2 s max Operating Humidity • 5-95% RH, non-condensing Start Up Rise Time • 12 ms max Storage Temperature • -40 ºC to + 85 ºC Hold Up Time • 15 ms min Shock • 20 G on 3 axis, 3 times each Line Regulation • ±0.5% max Vibration • 10-55 Hz, 0.15 at 1 octave/min for Transient Response • 4% max. deviation, 500 µs recovery time 30 mins on each 3 axis for a 25% load change Ripple & Noise • 65 mV for V1, 1% pk-pk on all other EMC & Safety outputs, 20 MHz BW Emissions • EN55022 FCC part 15 and VCCI level B Overvoltage Protection • V1, V2 & V5 only: 112-132% of nominal conducted and level A radiated Temperature • 0.04% / ºC Harmonic Currents • EN61000-3-2 Coefficient Voltage Flicker • EN61000-3-3 Remote Sense • On 3.3 V output only: Compensates for EFT/Burst • EN61000-4-4, level 2 Perf Criteria A up to 0.5 V drop Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, 3 V Perf Criteria A Magnetic Field • EN61000-4-8, 1 A/m Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • UL60950, CSA C22.2 No. 60950, EN60950, CE Mark LVD AC-DC AC-DC JPP130 Models and Ratings Output Output Output Output Output Model (3, 4) (3) (3) (2, 3) V1 V2 V3 V4 V5 Number +12.0 V/6.0 A JPP130PD02 +5.1 V/12.0 A +15.0 V/4.8 A JPP130PD03 +24.0 V/3.0 A JPP130PD04 +12.0 V/6.0 A 3.3 V/12.0 A JPP130PT01 +15.0 V/4.8 A 3.3 V/12.0 A JPP130PT02 +24.0 V/3.0 A 3.3 V/12.0 A JPP130PT03 +12.0 V/6.0 A +5.0 to 24.0 V/1.0 A JPP130PT04 +5.1 V/12.0 A +15.0 V/4.8 A +5.0 to 24.0 V/1.0 A JPP130PT05 +24.0 V/3.0 A +5.0 to 24.0 V/1.0 A JPP130PT06 +12.0 V/6.0 A -5.0 to -24.0 V/1.0 A JPP130PT07 +15.0 V/4.8 A -5.0 to -24.0 V/1.0 A JPP130PT08 +24.0 V/3.0 A -5.0 to -24.0 V/1.0 A JPP130PT09 +12.0 V/6.0 A +5.0 to 24.0 V/1.0 A 3.3 V/12.0 A JPP130PQ01 +15.0 V/4.8 A +5.0 to 24.0 V/1.0 A 3.3 V/12.0 A JPP130PQ02 +24.0 V/3.0 A +5.0 to 24.0 V/1.0 A 3.3 V/12.0 A JPP130PQ03 +12.0 V/6.0 A -5.0 to -24.0 V/1.0 A 3.3 V/12.0 A JPP130PQ04 +5.1 V/12.0 A +15.0 V/4.8 A -5.0 to -24.0 V/1.0 A 3.3 V/12.0 A JPP130PQ05 +24.0 V/3.0 A -5.0 to -24.0 V/1.0 A 3.3 V/12.0 A JPP130PQ06 +12.0 V/6.0 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A JPP130PQ07 +15.0 V/4.8 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A JPP130PQ08 +24.0 V/3.0 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A JPP130PQ09 +12.0 V/6.0 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A 3.3 V/12.0 A JPP130PM01 +5.1 V/12.0 A +15.0 V/4.8 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A 3.3 V/12.0 A JPP130PM02 +24.0 V/3.0 A +5.0 to 24.0 V/1.0 A -5.0 to -24.0 V/1.0 A 3.3 V/12.0 A JPP130PM03 Notes 1. Minimum 10 CFM required for 130 W operation. 2. V1 and V5 combined output power not to exceed 65 W; V2, V3 and V4 combined output power not to exceed 65 W; V3 and V4 combined output power not to exceed 30 W. 3. Adjustable range: V1 and V5 are adjustable ±10%, V3 and V4 can be trimmed 5-24 VDC and are factory-set to 12 VDC nominal. Accessible trim pots are assigned as VR1 for V1, VR2 for V5, VR3 for V3, VR4 for V4 and V2 is fixed. VR3 and VR4 trim pots are SMD types are located underneath PCB. 4. Minimum load of 0.8 A is required on V1 to regulate V5 where fitted. 5. PFD = TTL low gives warning of at least 10 ms before V1 output drops below 95% of nominal. This signal also provides a minimum of 100 ms delay after V1 is within regulation. Mechanical Details All dimensions are in inches (mm), tolerance: ±0.02 (±0.5) max Weight: 0.71 lbs (320 g) 0.225 (5.72) 0.16 (4.0) Dia Mounting Hole (4 PLS) PIN CONNECTIONS (1) Pin P1 P2 P3 P4 1 Live V1 -Sense (V5) V5 6 2 Neutral Com +Sense (V5) Com 3 - Com PFD signal - P2 4 - V3 or N/C Com - 5 - V4 or N/C - - DIRECTION 1 OF AIR FLOW 6 - V2 or N/C - - 4 P3 N 1 Note: P1 L 2 1. P4 only applies to models which have an Output V5 in the P4 Models and Rating table. 1 Derating Curve 4.55 (115.6) 130 5.00 (127.0) 10 CFM Forced-air Cooling 90 1.04 (26.4) 65 W 5 CFM Forced-air Cooling 45 W VR1 VR2 20 Convection Cooling 10 W 0.10 (2.54) 0.06 (1.60) 0 P2 & P4 Connectors: Can accept 18-12 AWG electric wires. -10 0 10 203040 50 60 P1 Mating Connector: Molex 09-50-3031 and 2878 series crimp terminals or equivalent. Ambient Temperature (˚C) P3 Mating Connector: Molex 22-01-1043 and 40445 series crimp terminals or equivalent. 04/04/05 1.20 (30.48) 3.00 (76.2) 2.55 (64.8) Output Power (W)
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the JPP130PQ04?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods