Industrial Trading chervon right Manufacturers chervon right X chervon right XP POWER chervon right AEL80US18
About product Specifications Features Datasheet FAQ

XP POWER AEL80US18

Image of XP POWER AEL80US18

Description

None available.

Part Number

AEL80US18

Price

Request Quote

Manufacturer

XP POWER

Lead Time

Request Quote

Category

None

Specifications

Cooling

Convection cooled

Earth Leakage Current

0.75 mA at 240 VAC

Input Frequency

47-63 Hz

Input Protection

T3.15 A, 250 V

Input Voltage

90-264 VAC

MTBF

>100 kHrs to MIL-HDBK-217F at 25 °C, GB

Operating Altitude

3000 m

Operating Humidity

5-95% RH, non-condensing

Operating Temperature

-20 °C to +70 °C, derate linearly from 100% power at +40 °C to 50% power at +70 °C

Power Factor

EN61000-3-2, Class A

Shock

10 g, 10 ms on 3 axes

Storage Temperature

-40 °C to +85 °C

Switching Frequency

63 kHz typical

Features

Datasheet

pdf file

XP Power- AEL80-ds1-578657421.pdf

140 KiB

Extracted Text

1580 Watts xppower.com AEL Series • Energy Efficiency Level V • CEC 2008 and EISA 2007 Compliant • Limited Power Source Approval • China Compulsory Certification (CCC) Qualified • +70 °C Operating Temperature • Compact Dimensions • 3 Year Warranty GREEN•POWER Specification Input General Input Voltage • 90-264 VAC Efficiency • See tables Input Frequency • 47-63 Hz Energy Efficiency • Model dependent, see tables Input Current • AEL15/20: 0.4 A max at 115 VAC Isolation • 3000 VAC Input to Output AEL40: 1.0 A max at 115 VAC 1500 VAC Input to Ground* AEL60: 1.6 A max at 115 VAC 500 VDC Output to Ground* AEL80: 1.1 A max at 115 VAC *Not C8 version Inrush Current • AEL15/20: 15/30 A max for 115/230 VAC, Switching Frequency • 63 kHz typical AEL40: 25/50 A max for 115/230 VAC, MTBF • >100 kHrs to MIL-HDBK-217F AEL60: 35/70 A max for 115/230 VAC, at 25 °C, GB AEL80: 45/92 A max for 115/230 VAC, cold start at 25 °C Environmental Earth Leakage Current • 0.75 mA at 240 VAC Operating Temperature • -20 °C to +70 °C, derate linearly from Power Factor • EN61000-3-2, Class A 100% power at +40 °C to 50% power at Input Protection • Internal fuse in line, +70 °C AEL15/20: T1 A, 250 V Storage Temperature • -40 °C to +85 °C AEL40: T2 A, 250 V Cooling • Convection cooled AEL60/80: T3.15 A, 250 V Operating Humidity • 5-95% RH, non-condensing No Load Input Power • 0.5 W maximum, model dependent Operating Altitude • 3000 m Shock • 10 g, 10 ms on 3 axes Output EMC & Safety Output Voltage • See tables Emissions • EN55022 level B conducted & radiated Minimum Load • No minimum load required Harmonic Current • EN61000-3-2 class A Hold Up Time • AEL15: 5 ms min, AEL20/40: 12 ms min, AEL60/80: 16 ms min, at full load Voltage Flicker • EN61000-3-3 110 VAC ESD Immunity • EN61000-4-2, level 3, Perf criteria A Start Up Delay • AEL20/40: 0.5 s, AEL15/60/80: 2.0 s Radiated Immunity • EN61000-4-3, 3 V/m, Perf criteria A max at full load 100 VAC EFT/Burst • EN61000-4-4, level 2, Perf criteria A Transient Response • 2% max deviation, recovery to within 1% Surge • EN61000-4-5, installation class 3, of nominal in 500 μs for 50% load change Perf criteria A Line Regulation • See tables Conducted Immunity • EN61000-4-6, level 2, Perf criteria A Load Regulation • See tables Magnetic Field • EN61000-4-8, 1 A/m, Perf criteria A Ripple & Noise • 1% pk-pk, 20 MHz bandwidth Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, Overvoltage Protection • 112-132% (AEL40/60/80 only) 100% 5000 ms Perf Criteria A, B, B Overload Protection • 110-150% (AEL20/40/60/80 only) Safety Approvals • EN60950-1: UL/cUL60950-1, Short Circuit Protection • Trip & restart (hiccup mode), Approved as Limited Power Source auto recovery (AEL15-60 only), China Compulsory Certification (CCC) qualified. Temperature • ±0.04%/°C Coefficient ACDC ACDC AEL15 Models and Ratings (3) (2) (5) (1) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number (4) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 †^ 12 W 5.0 VDC 2.40 A 7% 78% AEL15US05†^ 8.0 VDC 1.87 A 5% 79% AEL15US08†^ 9.0 VDC 1.66 A 5% 79% AEL15US09†^ 12.0 VDC 1.25 A 5% 80% AEL15US12†^ 15.0 VDC 1.00 A 5% 81% AEL15US15†^ 15 W 18.0 VDC 0.83 A 5% 82% AEL15US18†^ (4) 24.0 VDC 0.62 A 5% 78% AEL15US24 †^ (4) 30.0 VDC 0.50 A 5% 77% AEL15US30 †^ (4) 36.0 VDC 0.42 A 3% 75% AEL15US36 †^ 48.0 VDC 0.31 A 3% 81% AEL15US48†^ Notes 1. Standard input connector is IEC320-C14 Inlet. For optional IEC320-C6 Inlet, add suffix “C6” to model number e.g. AEL15US12C6. 2. Total regulation includes line regulation and load regulation. 3. Other output voltages available, contact sales for details. 4. Energy Efficiency Level IV. 5. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. † Available from Farnell & element14. See pages 284-290. ^ Available from Newark. See pages 291-296. Mechanical Details 3.58 (91.0) AC INPUT AC INPUT IEC-320-C6 INLET IEC-320-C14 INLET Notes 1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. 2. Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). 3. Output cable length is 48” (1220mm) approx. 4. Weight: 0.36 lbs (165 g) 5. For European mains lead order part: EU-MAINS-IEC or EU-MAINS-5 for C6 version. 6. For UK mains lead order part: UK-MAINS-IEC or UK-MAINS-5 for C6 version. 7. For US mains lead order part: US-MAINS-IEC or US-MAINS-5 for C6 version. 8. Mains lead length is 78“ (2000 mm) approx 1.42 (36.0) 1.50 (38.0) AEL20 Models and Ratings (3) (2) (4) (1) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number 15 W 5 VDC 3.00 A 5% 79% AEL20US05^ 12 VDC 1.67 A 4% 86% AEL20US12^ 15 VDC 1.33 A 4% 85% AEL20US15^ 20 W 24 VDC 0.83 A 3% 87% AEL20US24^ 30 VDC 0.67 A 3% 86% AEL20US30^ 48 VDC 0.42 A 3% 87% AEL20US48^ Notes 1. For optional class II version on AEL20 models only, add suffix ‘C2’ to model number e.g. AEL20US12C2. 2. Total regulation includes line regulation and load regulation. 3. Other output voltages available, contact sales for details. 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. ^ Available from Newark. See pages 291-296. Mechanical Details 3.90 (99.0) 0.02 (0.5) AC INPUT AC INPUT IEC-320-C8 INLET IEC-320-C6 INLET (Optional C2 Version) Notes 1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. 2. Output connector: 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). 3. Output cable length is 48” (1220mm) approx. 4. Weight: 0.37 lbs (170 g) 5. For European mains lead order part: EU-MAINS-C5 for AEL20, EU-MAINS-8 for AEL20 Class II. 6. For UK mains lead order part: UK-MAINS-5 for AEL20, UK-MAINS-8 for AEL20 Class II. 7. For US mains lead order part: US-MAINS-5 for AEL20, US-MAINS-8 for AEL20 Class II. 8. Mains lead length is 78“ (2000 mm) approx ACDC 1.22 (31.0) 1.65 (42.0) 0.04 (1.0) ACDC AEL40 Models and Ratings (2) (1) (4) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number (3) 25 W 5 VDC 5.00 A 7% 79% AEL40US05 ^ (3) 8 VDC 4.37 A 5% 82% AEL40US08 35 W (3) 9 VDC 3.88 A 5% 83% AEL40US09 ^ 12 VDC 3.33 A 5% 87% AEL40US12^ 15 VDC 2.67 A 5% 87% AEL40US15 18 VDC 2.22 A 5% 86% AEL40US18^ 40 W 24 VDC 1.67 A 3% 86% AEL40US24^ 36 VDC 1.11 A 3% 89% AEL40US36^ 48 VDC 0.83 A 3% 91% AEL40US48^ Notes 1. Total regulation includes line regulation and load regulation. 2. Other output voltages available, contact sales for details. 3. Energy Efficiency Level IV 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. ^ Available from Newark. See pages 291-296. Mechanical Details 4.65 (118.0) 0.04 (1.0) 0.02 (0.5) AC INPUT IEC-320-C14 INLET Notes 1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. 2. Output connector: 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). 3. Output cable length is 48” (1220mm) approx. 4. Weight: 0.64 lbs (275 g). 5. For European mains lead order part: EU-MAINS-IEC. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For US mains lead order part: US-MAINS-IEC. 8. Mains lead length is 78“ (2000 mm) approx 2.05 (52.0) 1.36 (34.5) 0.04 (1.0) AEL60 Models and Ratings (2) (1) (3) Max Output Power Output Voltage Output Current Total Regulation Efficiency Model Number 57 W 12 VDC 4.75 A 5% 87% AEL60US12 15 VDC 4.20 A 5% 88% AEL60US15 18 VDC 3.50 A 5% 88% AEL60US18 24 VDC 2.63 A 5% 88% AEL60US24 63 W 30 VDC 2.15 A 5% 90% AEL60US30 36 VDC 1.75 A 3% 90% AEL60US36 48 VDC 1.31 A 3% 90% AEL60US48 Notes 1. Total regulation includes line regulation and load regulation. 3. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Other output voltages available, contact sales for details. Mechanical Details 4.65 (118.0) 0.04 (1.0) 0.02 (0.5) AC INPUT IEC-320-C14 INLET Notes 1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. 2. Output connector: 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with centre positive (+) and outer shell negative (-). Length is 0.433 (11.0). 3. Output cable length is 48” (1220mm) approx. 4. Weight: 0.79 lbs (340 g). 5. For European mains lead order part: EU-MAINS-IEC. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For US mains lead order part: US-MAINS-IEC. 8. Mains lead length is 78“ (2000 mm) approx ACDC 2.05 (52.0) 1.36 (34.5) 0.04 (1.0) ACDC AEL80 Models and Ratings (2) (1) (4) Max Output Power Output Voltage Output Current Total Regulation Efficiency Model Number (3) 12 VDC 6.66 A 5% 85% AEL80US12 †^ (3) 15 VDC 5.38 A 5% 87% AEL80US15 †^ 18 VDC 4.44 A 5% 88% AEL80US18†^ 80 W 24 VDC 3.33 A 5% 87% AEL80US24†^ 30 VDC 2.66 A 5% 87% AEL80US30†^ 36 VDC 2.22 A 5% 88% AEL80US36†^ 48 VDC 1.66 A 5% 88% AEL80US48†^ Notes 1. Total regulation includes line regulation and load regulation. 3. Energy Efficiency Level IV. 2. Other output voltages available, contact sales for details. 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. † Available from Farnell & element14. See pages 284-290. ^ Available from Newark. See pages 291-296. Mechanical Details 5.75 (146.0) 0.04 (1.0) Pin Connections Pin Function 1 RTN 2 RTN 3 +VE 4 RTN +VE 5 SHELL GND 0.02 (0.5) DC Output 5 Pin Plug 3 5 AC INPUT 2 IEC-320-C14 INLET 4 1 Notes 1. All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max. 2. Output connector: 5 pin 180° DIN 3. Output cable length: 48” (1220mm) approx. 4. Weight: 1.5 lbs (700 g) 5. For European mains lead order part: EU-MAINS-IEC. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For US mains lead order part: US-MAINS-IEC. 8. Mains lead length is 78“ (2000 mm) approx 21-Jan-11 2.99 (76.0) 1.69 (43.0) 0.04 (1.0) 1.41 (36.0)

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the AEL80US18?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

XP POWER AEB100PS24 Power Cords

product

XP POWER AEB100PS125 Power Cords