XP POWER AEB70US48
Specifications
Hold Up Time
AEB36/45/70: 8 ms at 115 VAC General General General General
Initial Set Accuracy
±2%, set at 60% load General General General
Input Current
AEB361.00 A max General General General General
Input Frequency
47-63 Hz General General General General
Input Protection
Fitted with an internal fuse General General General General
Input Voltage
90-264 VAC General General General General
Inrush Current
AEB36 60 A max at 240 VAC General General General General
Line Regulation
±1% General General General General
Minimum Load
No minimum load required General General General General
Overload Protection
Trip & restart mode (hiccup mode) General General General General
Overvoltage Protection
Typical 125% max, recycle input to restart General General
Power Factor
Meets EN61000-3-2, class A General General General General
Ripple & Noise
1% pk-pk max, 20 MHz bandwidth General General General General
Storage Temperature
-20 °C to +85 °C General General General General
Temperature
±0.04%/°C General
Features
- China Compulsory Certfication (CCC) Qualified
- High Power Density
- Low Profile
- Single Outputs from 5 V to 48 V
- Universal Input
Datasheet
Extracted Text
36-100 Watts xppower.com AEB Series • CEC2008 & EISA2007 Compliant • Low Profile • Single Outputs from 5 V to 48 V • High Power Density • Universal Input • China Compulsory Certfication (CCC) Qualified • 3 Year Warranty Specification Input General Input Voltage • 90-264 VAC Efficiency • 85% minimum at 230 VAC & 100% load Input Frequency • 47-63 Hz Isolation • AEB36: 3000 VAC Input to Output AEB45/70/100: 3000 VAC Input to Output, Input Current • AEB36: 1.00 A max 1500 VAC Input to Ground. Negative AEB45: 1.20 A max output is connected to ground. For AEB70: 1.50 A max optional 500 VAC output to ground AEB100: 1.85 A max isolation add suffix ‘-F’ to model number Inrush Current • AEB36: 60 A max at 240 VAC Switching Frequency • AEB36/70: 60 kHz typical AEB45: 70 A max at 240 VAC AEB45: 100 kHz ± typical AEB70: 80 A max at 240 VAC AEB100: 80 kHz typical PFC converter AEB100: 120 A max at 240 VAC 130 kHz typical main converter Power Factor • Meets EN61000-3-2, class A MTBF • AEB36: >360 kHrs Earth Leakage Current • <3.5 mA (AEB45/70/100) AEB45: >300 kHrs Input Protection • Fitted with an internal fuse AEB70: >200 kHrs AEB36 T1A/250 VAC, AEB100: >150 kHrs AEB45/70/100 T2A/250 VAC to MIL-HDBK-217F at 25°C, GB No Load Input Power • <0.5 W Environmental Operating Temperature • AEB36/45/70: 0 ˚C to +60 ˚C derate linearly from 100% load at +40 ˚C to 60%, Output load at +60 ˚C, Output Voltage • See tables AEB100: 0 ˚C to +60 ˚C derate linearly from Initial Set Accuracy • ±2%, set at 60% load 100% load at +40 ˚C to 50% load at +60 ˚C Minimum Load • No minimum load required Storage Temperature • -20 ˚C to +85 ˚C Hold Up Time • AEB36/45/70: 8 ms at 115 VAC EMC & Safety AEB100: 20 ms at 115 VAC Line Regulation • ±1% Emissions • EN55022, Level B conducted & radiated Load Regulation • See tables Harmonic Currents • EN61000-3-2 Class A Ripple & Noise • 1% pk-pk max, 20 MHz bandwidth, Voltage Flicker • EN61000-3-3 see note 2 ESD Immunity • EN61000-4-2 Level 2 (contact) Perf Criteria A Overvoltage Protection • Typical 125% max, recycle input to restart EN61000-4-2 Level 3 (air) Perf Criteria A Overload Protection • Trip & restart mode (hiccup mode) Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A Short Circuit Protection • Continuous EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Temperature • ±0.04%/˚C Surge • EN61000-4-5, installation class 3, Coefficient Perf Criteria B Conducted Immunity • EN61000-4-6, Level 2 Perf Criteria A Magnetic Field • EN61000-4-8, 3 A/m Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals • EN60950-1: UL/cUL60950-1, China Compulsory Certification (CCC) qualified (AEB36/70 only) AC-DC AC-DC AEB Series Models and Ratings AEB36 Output Power Output Voltage Output Current Load Model (1) Maximum Nominal Maximum Regulation Number 20 W 5.0 V 4.00 A ±6% AEB36US05†^ 27 W 9.0 V 3.00 A ±5% AEB36US09†^ 30 W 12.0 V 2.50 A ±5% AEB36US12†^ 32 W 13.5 V 2.40 A ±5% AEB36US13†^ 36 W 15.0 V 2.40 A ±3% AEB36US15†^ 36 W 18.0 V 2.00 A ±2% AEB36US18†^ 36 W 24.0 V 1.50 A ±2% AEB36US24†^ 36 W 48.0 V 0.75 A ±2% AEB36US48†^ Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 μF ceramic capacitor and a 10 μF electrolytic capacitor. † Available from Farnell. See pages 266-269. ^ Available from Newark. See pages 270-272. AEB45 Output Power Output Voltage Output Current Load Model (1) Maximum Nominal Maximum Regulation Number 45 W 12.0 V 3.75 A ±3% AEB45US12^ 45 W 15.0 V 3.00 A ±3% AEB45US15^ 45 W 18.0 V 2.50 A ±2% AEB45US18^ 45 W 19.0 V 2.37 A ±2% AEB45US19^ 45 W 24.0 V 1.88 A ±2% AEB45US24^ 48 W 48.0 V 1.00 A ±2% AEB45US48^ Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 μF ceramic capacitor and a 10 μF electrolytic capacitor. 3. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number. ^ Available from Newark. See pages 270-272. AEB70 Output Power Output Voltage Output Current Load Model (1) Maximum Nominal Maximum Regulation Number 66 W 12.0 V 5.50 A ±5% AEB70US12†^ 69 W 15.0 V 4.60 A ±3% AEB70US15†^ 70 W 18.0 V 3.90 A ±2% AEB70US18†^ 72 W 19.0 V 3.70 A ±2% AEB70US19†^ 72 W 24.0 V 3.00 A ±2% AEB70US24†^ 72 W 48.0 V 1.50 A ±2% AEB70US48†^ Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 μF ceramic capacitor and a 10 μF electrolytic capacitor. 3. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number. † Available from Farnell. See pages 266-269. ^ Available from Newark. See pages 270-272. AEB100 Output Power Output Voltage Output Current Load Model (1) (3) Maximum Nominal Maximum Regulation Number 100 W 12.0 V 8.34 A ±4% AEB100PS12 100 W 12.5 V 8.00 A ±4% AEB100PS125 100 W 15.0 V 6.67 A ±4% AEB100PS15 100 W 24.0 V 4.17 A ±2% AEB100PS24 100 W 48.0 V 2.08 A ±2% AEB100PS48 Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 μF ceramic capacitor and a 10 μF electrolytic capacitor. 3. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number. AEB Series Mechanical Details All dimensions shown in inches (mm). AEB36 Cable length: 48” ±2” (1220 mm ±50 mm) Power Cord Order Part: UK - UK-MAINS-8 European - EU-MAINS-8 US - US-MAINS-8 1.97 (50.0) 4.33 (110.0) 0.79 0.47 (20.0) (12.00) IEC320-C8 Notes 1. Output connector is 5.5mm dia. outer barrel, inner dia. is 2.5 mm with a center +ve and outer shell -ve polarity. 2. Optional output connectors available, contact sales for details. 3. Weight: 0.42 lbs (190 g) approx. 4. Tolerance is ±0.02 (±0.5) maximum, except output cable length. 5. Length of mains lead: 76 inches (1930 mm) approx AEB45 Cable length: 48” ±2” (1220 mm ±50 mm) Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC 2.05 (52.0) 0.47 (12.00) 4.72 (120.0) IEC320-C14 1.22 (31.0) Notes 1. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5mm with a center + and outer shell - polarity. 2. Optional output connectors available, contact sales for details. 3. Weight: 0.62 lbs (280 g) approx. 4. Tolerance is ±0.02 (±0.5) maximum, except output cable length. 5. Length of mains lead: 76 inches (1930 mm) approx AC-DC AC-DC AEB Series Mechanical Details All dimensions shown in inches (mm). Cable length: 48” ±2” (1220 mm ±50 mm) AEB70 Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC 2.28 (58.0) 0.47 (12.00) 5.20 (132.0) IEC320-C14 1.20 (30.5) Notes 1. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5mm with a center + and outer shell - polarity. 2. Optional output connectors available, contact sales for details. 3. Weight: 0.76 lbs (345 g) approx. 4. Tolerance is ±0.02 (±0.5) maximum, except output cable length. 5. Length of mains lead: 76 inches (1930 mm) approx AEB100 Cable length: 48” ±2” (1220 mm ±50 mm) Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC 2.76 (70.0) 0.47 (12.00) 5.90 (150.0) IEC320-C14 1.38 (35.0) Notes 1. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5mm with a center + and outer shell - polarity. 2. Optional output connectors available, contact sales for details. 3. Weight: 1.36 lbs (600 g) approx. 4. Tolerance is ±0.02 (±0.5) maximum, except output cable length. 5. Length of mains lead: 76 inches (1930 mm) approx 06-May-09
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the AEB70US48?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods