SL POWER MINT1180A1275K01

Description
SL Power Electronics Manufacture of Condor/Ault Brands MINT1180A1275K01 MEDICAL INTERNAL PS 180W 12V MINT1180 12V - output voltage 100 ~ 240 VAC - input voltage 180W Switching (Open Frame) Chassis Mount 5.00"" L x 3.00"" W x 1.22"" H (127.0mm x 76.2mm x 31.1mm) -10°C ~ 70°C
Part Number
MINT1180A1275K01
Price
Request Quote
Manufacturer
SL POWER
Lead Time
Request Quote
Category
AC-DC Converter
Features
- 180W Convection Cooled Power
- Approved to CSA/EN/IEC/UL60601-1, 3rd Edition, 2 x MOPP Isolation
- Approved to CSA/EN/IEC/UL60950-1 2nd Edition
- Class I and Class II versions
- Efficiency 90% typical
- Ideal for 1U Applications
- RoHS Compliant
- Universal Input 90-264 VAC
- 3” x 5” x 1.3” Package
Datasheet
Extracted Text
MINT1180 180W Single Output Medical Series Features 3” x 5” x 1.3” Package 180W Convection Cooled Power Ideal for 1U Applications Class I and Class II versions Universal Input 90-264 VAC rd Approved to CSA/EN/IEC/UL60601-1, 3 Edition, 2 x MOPP Isolation nd Approved to CSA/EN/IEC/UL60950-1 2 Edition Efficiency 90% typical 3 Year Warranty RoHS Compliant Description The MINT1180 product family is the most cost-effective medically approved supply in the market with 180 watts of convection cooled output power in 3”X5” footprint. The series comes in eight different models ranging from rd 12 to 48V and has been approved to IEC60601-1 3 Edition, rated for 2 MOPP (Means of Patient Protection) isolation. This new single output power supply family has both Class I and II input versions and accepts wide input range of 90 to 264Vac. The typical 90% efficiency and convection cooled make this supply an excellent solution for HomeCare applications where the use of fans is not desired. Model Selection Output Ripple & Total Model Number Volts Current* Minimum Load Noise** Regulation OVP Threshold MINT1180A1275K01 12V 15.0A 0A 120mV pk-pk ±3% 14.0 ± 1.1V MINT1180A1575K01 15V 12.0A 0A 150mV pk-pk ±3% 18.5 ± 1.2V MINT1180A1875K01 18V 10.0A 0A 180mV pk-pk ±3% 21.5 ± 2.0V MINT1180A2475K01 24V 7.50A 0A 240mV pk-pk ±3% 29.0 ± 2.5V MINT1180A2875K01 28V 6.40A 0A 280mV pk-pk 33.5 ± 2.5V ±3% MINT1180A3275K01 32V 5.62A 0A 320mV pk-pk 36.0 ± 3.0V ±3% MINT1180A4875K01 48V 3.75A 0A 480mV pk-pk ±3% 56.0 ± 3.0V Notes: * Total convection power is 180 Watts. ** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. General Specifications 100-240Vac, ±10%, 47-63Hz, 1∅ Less than 3 sec. @115Vac & Full Load AC Input Turn On Time 120–370Vdc Input Current 115Vac: 1.8A, 230Vac: 0.9A Hold-up Time >16mS at 180W, 120Vac www.slpower.com MINT1180 REV 1.8, 15-OCT-13 1 MINT1180 180W Single Output Medical Series General Specifications (continued) Inrush Current 264Vac, cold start: will not exceed 55A Signals N/A F1, F2: 4.00A, 250VAC fuses provided on all Overload Input Fuses 120%-150% of rating, Hiccup Mode models Protection Earth Leakage Short Circuit Provided - no damage will occur if the output is <275μA@264Vac, 60Hz, NC; <400µA SFC shorted, auto recovery Current Protection Overvoltage OVP latch at 110%-130% of rated output Efficiency 88% typical Protection voltage. PFC: Fixed, 65kHz Switching Output Power 180W convection cooled Main Converter: Variable 35-200kHz, 65-70kHz Frequency at full load. 500μS typ. for return to within 0.5% of Input-Output: 4000Vac, 2 x MOPP Transient Isolation Input-Ground: 1800Vac, 1 x MOPP nominal, 50% load step. Δi/Δt <0.2A/µS. Response Output-Ground: 1500Vac Max Volt Deviation = 3% Operating -10°C to +70°C Ripple and Noise See chart Temperature Start Up at -40°C, full load Temperature Derate output power linearly above 50°C to 50% Output Voltage See chart at 70°C Derating Voltage Storage Fixed output -40°C to +85°C Adjustability Temperature Operating: -500 to 10,000 ft. Minimum Load Not required Altitude Non-operating: -500 to 40,000 ft. Total Regulation +/- 3% combined line, load and initial setting. Relative Humidity 5% to 95%, non-condensing Operating: 0.003g²/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 axes, 10 min/axis shocks total Vibration Shock Non-Operating: 0.026g²/Hz, 5.0grms overall, Non-Operating: Half-sine, 40 gpk, 10 ms, 3 3 axes, 1 hr/axis axes, 6 shocks total rd EN/CSA/UL/IEC 60601-1, 3 Edition W: 3.0” x L: 5.0” x H: 1.3” Dimensions Safety Standards nd EN/CSA/UL/IEC 60950-1, 2 Edition Weight 325g MTBF 214,194 hours, 25°C, 110Vac Output vs. Temperature Derating Curve 180W convection cooled, derate output power to 50% at 70°C. 200 150 100 50 0 -10 0 10 20 30 40 50 60 70 Temperature (°C) Convection www.slpower.com MINT1180 REV 1.8, 15-OCT-13 2 Output Power (W) MINT1180 180W Single Output Medical Series EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Subpart B, Class B EN55011/22; FCC Part 15, Class A with 6dB Margin Radiated Emissions EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge Static Discharge Immunity Radiated RF Immunity EN61000-4-3, 3V/m. Criteria A. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A Conducted RF Immunity EN61000-4-6, 3Vrms, Criteria A Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m, Criteria A EN61000-4-11, 5% Vnom: 0.5cycle; 40% Vnom: 5 cycles, 70% Vnom: Voltage Dip Immunity 25 cycles, Criteria A EN61000-3-2, Class A, B, C, & D Line Harmonic Emissions Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing Notes: 1. All dimensions in inches (mm), tolerance is +/-0.000”. 2. Mounting holes should be grounded for EMI purposes. 3. FG is safety ground connection. 4. The power supply requires mounting on metal standoffs 0.20” (5mm) in height, min. [4] x 0.156 4 PLCS MTG HOLES Connector Information Input Connector Ground DC Output Connector J100 (FG) J300 PIN 1) AC LINE Term. 1,2,3: RTN PIN 2) EMPTY 0.25” FASTON TAB Term. 4,5,6: +Vout PIN 3) AC NEUTRAL Mating Connector: Mating Connector: Mating Connector: AMP 640250-3 AMP 640250-6 Molex 190020001 Pins: 640252-2 Pins: 640252-2 Data Sheet © 2013 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com MINT1180 REV 1.8, 15-OCT-13 3
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the MINT1180A1275K01?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods