SL POWER GLD150-28
Datasheet
Extracted Text
GLD150 Gold Performance Medical Switchers 150 Watt Single Output FEATURES: • Compact 4.5” x 7” x 1.7” size Power factor corrected to IEC 1000-3-2 Class A Less than 300 µA leakage EMI compliance to CISPR11, FCC Class B Power fail and remote sense standard Medical Approved to UL2601-1, IEC601-1/60601-1 and CSA-C22.2 No. 601.1 2 year warranty marked to LVD SPECIFICATIONS: EMI/EMC Compliance Ac Input All models include built-in EMI filtering to meet the EMC require- 85-264 Vac, 47-63 Hz single phase. Input Current ments of IEC601-1. Unless otherwise stated, all tests are done at full load and 115 and 230 Vac input. 2.8 A line current maximum, at 90 Vac, 60 Hz with full rated load, power factor .99 typical, .96 minimum. Input current harmonic content meets the requirements of IEC1000-3-2. Conducted Emissions EN55011, Class B; FCC Class B Static Discharge EN61000-4-2, 6 kV contact 8 kV air Output Power RF Field Susceptibility EN61000-4-3, 3V/meter 150 W with convection cooling, 180 W with fan cooling. Efficiency Fast Transients / Bursts EN61000-4-4, 2 kV, 5 kHz Minimum 80% at full rated load with 230 Vac Input. Approximately Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Conducted RF Susceptibility EN61000-4-6, 3V 3% less at 115 Vac. Voltage Sags & Surges EN61000-4-11 Hold-Up Time Outputs will remain within regulation limits for 25 ms minimum from Inrush Current loss of ac input at full load, 10 ms before Power Fail indication. Inrush 240 Vac is less than 37 A, averaged over the first ac half- Dc Ouput Total regulation is the maximum deviation from the nominal voltage cycle under cold start conditions. Limiting provided by internal thermistors. for all steady state loading conditions. Peak ratings are for 60 s Fan Output maximum duration, 10% duty cycle. Overload Protection An additional 12 Vdc, 250 mA output suitable for powering a dc Fully protected against short circuit and output overload. Short fan is included in all models. The fan output is both current limited and thermally protected. circuit protection is cycling type power limit. Thermal Shutdown Minimum Load No minimum load required to maintain output specifications. Provided as a standard feature. Designed to protect unit from prolonged over temperature. Output Noise Power Fail 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the TTL / CMOS compatible output goes low (<0.5 V) 8 ms before output voltage drops more than 4% below nominal voltage upon power supply. loss of ac power. Transient Response Main Output - 500 µs typical response time for return to within Power Good 0.5% of final value for a 50% load step change, Di/Dt< 0.2 A µs. TTL / CMOS compatible output goes high more than 100 ms after V1 reaches regulation and should assure that sufficient Maximum voltage deviation is 3%. energy is stored in the input section to provide normal power Remote Sense Provided as a standard feature on all models. fail/shutdown. Medical Approvals Overvoltage Protection All models are Certified to be in compliance with the Built in on all models. Input Protection applicable requirements of UL2601-1, CSA-C22.2 No. 601.1, Internal ac fuses provided on both lines on all units. IEC601-1/60601-1. Leakage Current Voltage Adjustment Output Voltage is adjustable +/- 5% with user adjustable potentiometer. 70 µA, 132 Vac @ 60 Hz normal conditions. Single fault condi- Temperature Coefficient tions, 130 µA, 254 Vac @ 50 Hz. 0.03% / °C typical on all outputs. Design Verification Documents The “Gold” series has undergone rigorous review and design Overshoot Less than 2% overshoot at turn-on under all conditions, less than analysis. The following product documentation is available upon 1% overshoot at turn-off under all conditions. request; 1. MTBF study Inhibit Inhibit signal is pulled to the V1 output common to reduce average 2. DVT Data output voltage to less than 5% of nominal. 3. EMC / Susceptibility test results Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 60 GLD150 Medical Switchers 150 Watt Multiple Output Medical Output Output Output Voltage Total OVP Ripple/ Noise Model Voltage Current (A) Current (B) Adjustment Regulation Setpoint GLD150-12 12 V 12.5 A 15 A ± 5% 2% 14 + 1.1 V 1% GLD150-15 15 V 10 A 12 A ± 5% 2% 18.5 + 1.5 V 1% GLD150-24 24 V 6.2 A 7.5 A ± 5% 2% 28 + 2.5 V 1% GLD150-28 28 V 5.3 A 6.4 A 2% 34 + 2.8 V 1% ± 5% GLD150-48 48 V 3.2 A 3.75 A 2% 55 + 4.0 V 1% ± 5% Notes: A. Maximum continuous current rating for unrestricted convection cooling. B. Maximum continuous current rating with 150 LFM air or peak rating. C. Add “C” suffix for cover option and derate convection rating to 130 W. GLD150 MECHANICAL SPECIFICATIONS INPUT J1 MOLEX P.C.B. HEADER P/N: 39-30-2056 PIN 1) AC GROUND PIN 2) N/C PIN 3) AC NEUTRAL PIN 4) N/C PIN 5) AC LINE MATING CONNECTOR MOLEX P/N HOUSING 39-01-4051 CONTACT 39-00-0182 SIGNALS J2 AMP P.C.B. HEADER P/N 641215-6 PIN 1) INHIBIT PIN 2) +SENSE PIN 3) POWER GOOD PIN 4) -SENSE PIN 5) COMMON PIN 6) POWER FAIL MATING CONNECTOR AMP P/N HOUSING 770602-6 CONTACT 770666-6 OUTPUT J3 MOLEX P.C.B. HEADER P/N: 39-29-9085 PINS 3,4,7,8) +Vout PINS 1,2,5,6) RETURN MATING CONNECTOR MOLEX P/N HOUSING 39-01-2080 CONTACT 39-00-0182 FAN AMP P.C.B. HEADER P/N: 641215-2 PINS 1) RTN PINS 2) +12V MATING CONNECTOR AMP P/N HOUSING 770602-2 CONTACT 770666-02 Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C HH umidity (A)0H to 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions Sg hock (B) 20 40 g before application of power. pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 61
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the GLD150-28?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods