Description
Skynet SNP-Z057 ACDC Power Supply. 65W | Open Frame | AT | +12V
Part Number
SNP-Z057
Price
Request Quote
Manufacturer
SKYNET
Lead Time
Request Quote
Category
Power Supply
Specifications
Cooling
free air convection
Efficiency
78%~87% depends on models at rated load and 115VAC
EMI
FCC "B" EN55022"B", EN55011"B"
EMS
EN61000-4-2,-3,-4,-5,-6,-8,-11
Hold Up Time
14mS typical at rated load and 115VAC
Input Frequency
47Hz to 63Hz
Input Voltage
90VAC to 264VAC
Inrush Current
less than 30A at 115VAC, less than 60A at 230VAC cold start, 25°C
Line Reg.
±0.5%
Load
Min:0A; Rated:4.6A; Peak:5.4A
Load Reg.
±0.5%
Operating Temperature
0 to 70°C convection derating: 2.5% / °C > 50°C
Output Rail
+12V
Over load protection
auto recovery
Over Voltage Protection
latch off
Ripple Noise
±0.5%
Safety
UL 60950-1, UL 60601-1, CSA C22.2 No. 60950-1, No. 601.1, EN 60950-1, EN 60601-1
Short circuit protection
auto recovery
Storage Temperature
-40°C to +85°C
Voltage accuracy
+11.9V~+12.1V
Features
- 2" x 4" footprint
- 5.7 Watt per cubic inch
- Compact Size with only 1.1"" Height
- Efficiency between 78% to 87%
- ITE & Medical Dual Safety Approvals
- Operating from 0°C to 70°C by convection
Datasheet
Extracted Text
Rated 55W ITE & Medical Applications Peak 65W (Universal) SNP-Z05 Series Features: Only 1.1 inch height 5.7 Watt per cubic inch With ITE & Medical safety Efficiency between 78% to 87% o o Operating from 0 C to 70 C by convection General Specifications: Input voltage ...........................................90VAC to 264VAC Short circuit protection ..................................... auto recovery Input frequency.................................................47Hz to 63Hz Over voltage protection ........................................... latch off o Inrush current ................................ less than 30A at 115VAC Operating temperature .......................... 0 to 70 C convection o o less than 60A at 230VAC derating: 2.5% / C > 50 C o cold start, 25 C Cooling ..................................................... free air convection o o Efficiency .............................. 78%~87% depends on models Storage temperature .......................................-40 C to +85 C at rated load and 115VAC EMI .......................................................................... FCC "B" Hold up time .................................................... 14mS typical EN55022"B", EN55011"B" at rated load and 115VAC EMS ...................................... EN61000-4-2,-3,-4,-5,-6,-8,-11 Over load protection ........................................ auto recovery Safety ..............................................UL 60950-1, UL 60601-1 CSA C22.2 No. 60950-1, No. 601.1 EN 60950-1, EN 60601-1 Mechanical Specifications: Notes: 1. Dimensions shown in mm as left. Tolerance: + -1mm (Excluding cables). 2. Size: 101.6 X 50.8 X 28 (mm) 4" X 2" X 1.102" 3. Packing: Net weight: 140 g approx. / unit Gross weight: 13.5 kg approx. / carton, 80 units / carton Carton size (mm): 382 (L) x 374 (W) x 277 (H) 4. Connectors: AC input : JST B2P3-VH or equivalent DC output : JST B4P-VH or equivalent for single output JST B7P-VH or equivalent for multiple outputs 5. Output Pin assignment: PIN NO. 1 2 3 4 SNP-Z056 +5V +5V GND GND SNP-Z057 +12V +12V GND GND SNP-Z058 +15V +15V GND GND SNP-Z059 +24V +24V GND GND SNP-Z05T +48V +48V GND GND SNP-Z05B +3.3V +3.3V GND GND -Claus- JUN. 2006 ** This data sheet is only for model selection. For business, engineering specification by model must be used. 2-1 Rated 55W ITE & Medical Applications Peak 65W (Universal) SNP-Z05 Series Output Specifications: MODEL OUTPUT LOAD VOLTAGE RIPPLE LINE LOAD NO. RAIL MIN. RATED PEAK ACCURACY NOISE REG. REG. SNP-Z056 +5V 0A 7A 9A +4.95V~+5.05V 50mVpp ±0.5% ±1% SNP-Z057 +12V 0A 4.6A 5.4A +11.9V~+12.1V ±0.5% ±0.5% ±0.5% SNP-Z058 +15V 0A 3.7A 4.3A +14.9V~+15.1V ±0.5% ±0.5% ±0.5% SNP-Z059 +24V 0A 2.3A 2.7A +23.8V~+24.2V ±0.5% ±0.5% ±0.5% SNP-Z05T +48V 0A 1.2A 1.4A +47.6V~+48.4V ±0.5% ±0.5% ±0.5% SNP-Z05B +3.3V 0A 8A 10A +3.25V~+3.35V 50mVpp ±0.5% ±1.5% Note: o 1. The max. load can be continuously provided at 40 C and convection cooling conditions. The peak load can be temporarily provided up to 8 sec- onds. 2. At factory, all outputs in 60% rated load condition, each output is checked to be within the accuracy range while the main output is setting to within the specified accuracy range at rated load. 3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 4. Load regulation is defined by changing ±40% of measured output load from 60% rated load at another output set to 60% rated load. 5. Ripple & noise is measured by using 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal line. For SNP-Z056 and SNP-Z05B, one extra 47uF electrolytic capacitor should be added. 6. Hold up time is measured from the end of the last charging pulse to the time which the main output drop down to regulation limit at rated load and nominal line. -Claus- ** This data sheet is only for model selection. For business, engineering specification by model must be used. 2-2 JUN. 2006
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the SNP-Z057?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods