SKYNET SNP-9544
Specifications
Depth or Length
127 mm
Height
33 mm
Input Voltage Range Type
AC-DC (Auto Ranging)
Input Voltage Type
AC/DC
Operating Temperature
0 C to 50 C
Storage Temperature
-20 C to 85 C
Width
76.2 mm
Datasheet
Extracted Text
General Purpose 40W (Universal) SNP-954 Series Description: SNP-954 series is a 40W, universal input switching mode power supply. It is with various output options, which includes triple outputs, dual outputs and single output. It is designed to comply with UL, CSA, VDE regulations and EMI Vfg 243/ 1991. Model available: SNP-9541 for 5V/3A, 12V/2A, -12V/0.3A SNP-9542 for 5V/3A, 12V/2A, -5V/0.3A SNP-9543 for 5V/3A, 12V/2A SNP-9543-H for 5V/5A, 3.3V/4A SNP-9544 for 5V/3A, 15V/1.5A, -15V/0.3A SNP-9546 for 5V/8A SNP-9547 for 12V/3.3A SNP-9548 for 15V/2.6A SNP-9549 for 24V/1.7A General Specifications: Input voltage ..................................... 90VAC to 264VAC Over load protection ................................. auto recovery Input frequency.......................................... 47Hz to 63Hz & latch off for SNP-9543 Inrush current...................for SNP-9541,9542,9543,9544 Short circuit protection .............................. auto recovery less than 30A at 115VAC & latch off for SNP-9543 (Cold start) less than 60A at 230VAC Over voltage protection ..................................... crowbar o Inrush current ..................for SNP-9546,9547,9548,9549 Operating temperature (open frame type) ..........0 to 50 C less than 10A at 115VAC Cooling .............................................. free air convection o o (Cold start) less than 21A at 230VAC Storage temperature ..................................-20 C to +85 C Efficiency ............................................... higher than 70% EMI conduction standard ............................Vfg 243/1991 at rated load and 115VAC FCC Class "B" Hold up time..........................................longer than 20ms Safety .................................................. meet UL 60950-1 at rated load and 115VAC CSA 22.2 No.60950-1 EN 60950-1 Mechanical Specifications: Notes: SNP-9541 1. Dimensions shown in mm (inch) as left. Tolerance specified is ± 0.4mm. o4.0(0.157)TYP. MOUNTING HOLES 2. Size: 127.0(5.0) 76.2 X 127 X 33 (mm) 3" X 5" X 1.3" TB2 3. Mounting holes: 64.8 X 115.6 (mm) 76.2(3.0) 64.8(2.551) TB1 2.55" X 4.55" 4. Packing: Net weight: 250 g approx. / unit TO CHASSIS GROUNDING Gross weight: 14 kg approx. / carton, 48 units / carton 5.0(0.197) 115.6(4.551) Carton size (mm): 397 (L) x 339 (W) x 327 (H) 5. Connectors: 30.6(1.206)MAX. TB1 : Molex 5277-2 or equivalent for AC input TB2 : Molex 5273-x or equivalent for DC output 2.4(0.095)MAX. -Ted- ** This data sheet is only for models selection. For business, engineering specification by model must be used. MAR. 2001 4-1 General Purpose 40W SNP-954 Series (Universal) 6. TB2 Assignment Pin Pin 1 2 3 4 5 678 12 3 4 5 6 Model Model SNP-9541 +12V +5V +5V GND GND -12V SNP-9546 +5V +5V +5V GND GND GND SNP-9542 +12V +5V +5V GND GND -5V SNP-9547 +12V +12V +12V GND GND GND SNP-9543 +12V GND GND +5V SNP-9548 +15V +15V +15V GND GND GND SNP-9543-H +3.3V +3.3V GND GND GND GND +5V +5V SNP-9549 +24V +24V +24V GND GND GND SNP-9544 +15V +5V +5V GND GND -15V Output Specifications: MODEL OUTPUT LOAD VOLTAGE RIPPLE LINE LOAD NO. RAIL MIN. RATED PEAK ACCURACY NOISE REG. REG. SNP-9541 +5V 0A 3A 6A +4.95V~+5.05V 50mV ±1% ±3% +12V 0A 2A 4A +11.4V~+12.6V 120mV ±2% ±3% -12V 0A 0.3A 0.5A -11.4V~-12.6V 120mV ±3% ±5% SNP-9542 +5V 0A 3A 6A +4.95V~+5.05V 50mV ±1% ±1% +12V 0A 2A 4A +11.4V~+12.6V 100mV ±2% ±3% -5V 0A 0.3A 0.5A -4.75V~-5.25V 100mV ±3% ±5% SNP-9543 +5V 0A 3A +4.95V~+5.05V 50mV ±1% ±1% +12V 0A 2A 5.5A +11.4V~+12.6V 120mV ±1% ±4% SNP-9543-H +5V 0A 5A 8A +4.95V~+5.05V 50mV ±1% ±1% +3.3V 0A 4A 8A +3.14V~+3.47V 50mV ±1% ±1% SNP-9544 +5V 0A 3A 5A +4.95V~+5.05V 50mV ±1% ±1% +15V 0A 1.5A 3A +14.25V~+15.75V 150mV ±1% ±3% -15V 0A 0.3A 0.5A -14.25V~-15.75V 150mV ±1% ±3% SNP-9546 +5V 0A 8A 12A +4.75V~+5.25V 50mV ±1% ±1% SNP-9547 +12V 0A 3.3A 5A +11.9V~+12.1V 100mV ±1% ±1% SNP-9548 +15V 0A 2.6A 4A +14.85V~+15.15V 100mV ±1% ±1% SNP-9549 +24V 0A 1.7A 2.5A +23.8V~+24.2V 240mV ±1% ±1% Note: 1. Each output can provide up to peak load temporarily. Continuous staying in more than rated load is not allowed. 2. At factory, all outputs in 60% rated load condition, each output is checked to be within the accuracy range while the main output is setting to within the specified accuracy range at rated load. 3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 4. Load regulation is defined by changing ±40% of measured output load from 60% rated load at another output set to 60% ratedload. 5. Ripple & noise is measured by using 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal line. 6. Hold up time is measured from the end of the last charging pulse to the time which the main output drop down to regulation limit at rated load and nominal line. 7. Rated load is maximum loading for flat mounting and free air convection cooling. -Ted- ** This data sheet is only for models selection. For business, engineering specification by model must be used. 4-2 MAR. 2001 General Purpose 40W (Universal) SNP-954 Series Performance for SNP-9541: 1. Switching frequency ripple 2. Line frequency ripple +5V/3A +5V/3A 50mV/div 50mV/div +12V/2A 50MV/div +12V/2A 50mV/div 0.1V/div -12V/0.3A -12V/0.3A 0.1V/div 10us/div 5ms/div 3. Output turn on wave form 4. Output turn off wave form +12V/2A +12V/2A +5V/3A +5V/3A -12V/0.3A -12V/0.3A 5V/div , 2ms/div 5V/div , 2ms/div 5. Hold-up time 6. Over voltage protection Trip point around 6V AC:115V 2V/div Primary DC 50V/div 5ms/div 2V/div , 10ms/div -Ted- ** This data sheet is only for models selection. For business, engineering specification by model must be used. MAR. 2001 4-3 General Purpose 40W SNP-954 Series (Universal) 7. + 5V step response 8. + 12V step response 0.5V/div +5V 0.2V/div +12V 0.5V/div 0.1V/div +5V +12V 2ms/div 2ms/div +5V steps from 0.6A to 3A +12V steps from 0.4A to 2A other output at 60% load other output at 60% load 9. FCC B performance 10. Vfg 243 performance EMISSION LEVEL (dBuV) 9 Nov. 1993 13: 54: 20 EMISSION LEVEL (dBuV) 9 Nov. 1993 17: 05: 33 100 120 FCC CFR 47, Pt 15J - CONDUCTED Vfg 243 / 1991 -CONDUCTED SNP-9541 R/D934405 SNP-9541 R/D934405 AC: 115V L1 AC: 220V L2 80 100 CLASS A 60 80 CLASS B UNDER 6dB QUASI-PEAK 40 60 AVERAGE 40 20 .01 .1 1 10 30 .45 1 10 30 FREQUENCY (MHz) FREQUENCY (MHz) -Ted- ** This data sheet is only for models selection. For business, engineering specification by model must be used. 4-4 MAR. 2001
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the SNP-9544?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods