SCHNEIDER ELECTRIC SU3040D300CN

Description
Schneider Electric SU3040D300CN All-in-One Combination Service Entrance Devices | Ring Style UG 300A
Part Number
SU3040D300CN
Price
Request Quote
Manufacturer
SCHNEIDER ELECTRIC
Lead Time
Request Quote
Category
None
Datasheet
Extracted Text
Table of Contents Section 1 Load Centers ® 1-2 QO Miniature Circuit Breakers ® QO Plug-On Circuit Breakers 1-2 Accessories 1-4 ® 1-5 QO Load Centers Indoor-1Ø, Main Lug 1-5 Indoor, 1Ø Main Circuit Breaker 1-6 Rainproof 1Ø, Main Lugs, Main Circuit Breaker 1-7 3Ø, Main Lugs, Main Circuit Breaker 1-8 New! Backup Power Solutions 1-9 QO Load Center, Page 1-5 Special Applications 1-10 ® ® 1-11 QO and Homeline Load Centers Load Center Value Pack 1-11 1-11 Load Center Accessories QO Load Center Accessories 1-12 ® QO and Homeline Accessories 1-13 ® 1-14 Homeline Circuit Breakers ® 1-15 Homeline Load Centers Indoor, 1Ø, Main Lug, Main Circuit Breaker 1-15 Homeline Load Center, Page 1-11 Rainproof, 1Ø, Main Lug, Main Circuit Breakers 1-16 ® ® 1-17 QO and Homeline Load Centers Indoor Load Centers–Dimensions, Knockouts 1-17 Rainproof—Dimensions, Knockouts, Bolt-on Hubs 1-18 1-19 Combination Service Entrance Devices New! Meter Mains, 100—200 A 1-19 All-In-Ones, 100—225 A 1-20 Meter Mains and All-In-Ones, 300—400 A 1-21 Circuit Breakers, Accessories, Hubs 1-22 Dimensions 1-23 1-24 Enclosed Devices Combination Service ® 1-25 Servicepak Power Outlet Panels Entrance Devices, Page 1-19 © 2009 Schneider Electric 1-1 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® ® QO Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.schneider-electric.us ® Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or ® Speed-D switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a ® The Square D exclusive Qwik-Open mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 A and 20 A QO circuit breakers. Table 1.1: Plug-On Circuit Breakers Table 1.2: QO/QOB Ring Terminal QO 1P (20% $ Price Adder)—Factory-installed only 2P—120/240 Vac 2P—240 Vacc 3P—240 Vac 1P—120/240 Vac Amperes Common Trip Common Trip Common Trip Rating b Ampere Rating Poles Suffix Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 10 k AIR 10–30 A 1, 2, 3 5237 10 A QO110 29.10 QO210 67.00 —— QO310 248.00 35–60 A 1,2 5238 15 A QO115de 29.10 QO215d 67.00 QO215H 200.00 QO315d 248.00 35–50 A 3 20 A QO120de 29.10 QO220d 67.00 QO220H 200.00 QO320d 248.00 70–110 A 2 5273 25 A QO125d 29.10 QO225d 67.00 QO225H 200.00 QO325d 248.00 60–100 A 3 30 A QO130d 29.10 QO230d 67.00 QO230H 200.00 QO330d 248.00 1 Space Required 35 A QO135 d 29.10 QO235d 67.00 —— QO335d 248.00 Table 1.3: Wire Sizesb QOT 1P Tandem 40 A QO140 d 29.10 QO240d 67.00 QO240H 200.00 QO340d 248.00 Circuit Breaker Wire Size Ampere Rating Type (AWG/kcmil) 45 A QO145 d 29.10 QO245d 67.00 —— QO345d 248.00 50 A QO150 d 29.10 QO250d 67.00 QO250H 200.00 QO350d 248.00 10–30 A 14–8 Al/Cu QO 60 A QO160 d 29.10 QO260d 67.00 QO260H 200.00 QO360d 248.00 10–30 A (2) 14–10 Cu 1P 70 A QO170 d 67.00 QO270d 134.00 QO270H 224.00 QO370d 315.00 35–70 A 8–2 Al/Cu 80 A — — QO280d 189.00 QO280H 315.00 QO380d 366.00 10–30 A 14–8 Al/Cu 90 A — — QO290d 189.00 QO290H 315.00 QO390d 366.00 10–30 A (2) 14–10 Cu QO 100 A — — QO2100d 189.00 QO2100H 315.00 QO3100d 366.00 35–70 A 8–2 Al/Cu 2P 110 A — — QO2110d 428.00 — — — — 80–125 A 4–2/0 Al/Cu 125 A — — QO2125d 428.00 — — — — 150–200 A 4–300 Al/Cu 1 Space Required 14–8 Al/Cu, (2) 14-10 150 A — — QO2150dfk 491.00 —— — — 10–30 A Cu QO 2P QO 175 A — — QO2175dfk 491.00 — — — — 3P 35–70 A 8–2 Al/Cu 200 A — — QO2200dfk 491.00 — — — — 80–125 A 4–2/0 Al/Cu Molded Case Switch 60 A max.–240 —— QO200 70.00 QO300 248.00 QOB-VH 110–150 A 4–300 Al/Cu Vac Molded Case Switch 100 A max.–240 —— QO2000i 200.00 QO3000i 366.00 QOT 15–20 A 12–8 Al 14–8 Cu Vac 22 k AIRd 15–30 A 12–8 Al 14–8 Cu QO-AFI, QO-GFI or QO-EPD 15 A QO115VH e 63.00 QO215VHg 146.00 —— QO315VHg 371.00 40, 50, 60 A 12–4 Al 14–6 Cu 20 A QO120VH e 63.00 QO220VHg 146.00 —— QO320VHg 371.00 QO-PL 10–60 A 12–2 Al 14–2 Cu 2 Spaces Required 25 A QO125VH 73.00 QO225VHg 146.00 —— QO325VHg 371.00 30 A QO130VH 73.00 QO230VHg 146.00 —— QO330VHg 371.00 Table 1.4: QOT Tandem Circuit 40 A — — QO240VHg 146.00 —— QO340VHg 371.00 Breakers QO2200 2P 200 A 50 A — — QO250VHg 146.00 —— QO350VHg 371.00 Ampere Ratingb Cat. No.d $ Price 60 A — — QO260VHg 146.00 —— QO360VHg 371.00 1P—120/240 Vac 70 A — — QO270VHg 224.00 —— QO370VHg 477.00 15 A and 15 A QOT1515 58.00 80 A — — QO280VHg 315.00 —— QO380VHg 530.00 15 A and 20 A QOT1520 58.00 90 A — — QO290VHg 315.00 —— QO390VHg 530.00 20 A and 20 A QOT2020 58.00 100 A — — QO2100VHgh 315.00 —— QO3100VHg 530.00 2P—120/240 Vac Common Trip 110 A — — QO2110VHgh 1034.00 —— — — Order two QOT1515 or QOT2020 circuit breakers and 125 A — — QO2125VHgh 1034.00 —— — — handle tie QOTHT for common switching of center two poles. 150 A — — QO2150VHfgk 1061.00 —— — — 175 A — — QO2175VHfgk 1061.00 —— — — 4 Spaces Required 200 A — — QO2200VHfgk 1061.00 —— — — Table 1.5: Replacement Tandem 42 k AIRd Circuit Breakers QO 3P 40 A — — QOH240 i 317.00 —— — — For use in Old Style Non-Class CTL 45 A — — QOH245 i 317.00 —— — — QO Load Centers—10 k AIR 50 A — — QOH250i 317.00 —— — — Ampere Ratingb Cat. No.d $ Price 60 A — — QOH260i 317.00 —— — — 1P—120/240 Vac—1 Space Required 70 A — — QOH270 528.00 — — — — 15 A and 15 A QO1515 73.00 80 A — — QOH280 651.00 — — — — 15 A and 20 A QO1520 73.00 90 A — — QOH290 651.00 — — — — 20 A and 20 A QO2020 73.00 100 A — — QOH2100 651.00 — — — — 20 A and 30 A QO2030 73.00 110 A — — QOH2110i 1389.00 — — — — 30 A and 20 A QO3020 73.00 3 Spaces Required Two 1P Individual Trip—120/240 Vac—2 Spaces 125 A — — QOH2125 1389.00 —— — — Required 65 k AIRd 15 A and 15 A Order Two QO1515 or QO2020 circuit breakers and handle tie QOTHT 15 A QH115e 117.00 QH215 293.00 —— QH315d 507.00 15 A and 20 A 20 A QH120e 117.00 QH220 293.00 —— QH320 507.00 20 A and 20 A — — 25 A QH125i 117.00 QH225i 293.00 —— QH325i 507.00 20 A and 30 A QO20303020j 134.00 30 A QH130 117.00 QH230 293.00 —— QH330 507.00 30 A and 20 A — — a See Digest Section 1 for load centers, and Section 9 for panelboards and interiors. QOT Tandem o o b 10–30 A circuit breakers are suitable for use with 60 C or 75 C conductors. 35–125 A circuit breakers Current limiting QOT o are suitable for use with 75 C conductors. tandem circuit c UL Listed 5 k AIR on corner grounded Delta systems. breakers have a d UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor mounting cam as group combinations and marked for use with HACR type circuit breakers. shown. Installation into a QO load e UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. center can only be f Requires four spaces (1 AWG–300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads. made in those g UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, QO-AFI, and QO-PL 10 k AIR circuit breakers positions having a Mounting Cam to permit their application at 22 kA fault level. mounting pan rail Rail Bead h 100 A maximum branch mounted opposite. slot. Meets i Order only. Contact your local Field Office. Paragraph 408.15 of Pan Rail Slot ®. j Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. the NEC UL Listed as Class CTL k Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater. Interupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-12 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-53 © 2009 Schneider Electric 1-2 Discount DE2A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® ® QO Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.schneider-electric.us ® QO Arc-Fault Circuit Breaker QO-HID QO arc-fault circuit breakers provide protection for Series HID circuit breakers are for use on circuits feeding and Parallel Type Arcing as required by the NEC and local fluorescent and high intensity discharge (HID) lighting code adoption, and comply with UL1699. systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table 1.6: QO Arc Fault Circuit Breakersa 1P 1P 120 Vac 1P 120 Vac Table 1.10: QO-HID Circuit Breakers QO-AFI 10 k AIR 22 k AIR Ampere 2P Common Trip 3P Common Trip Circuit Breaker Type 1P 120/240 Vac Rating 1 Space Required 1 Space Required 120/240 Vac 240 Vac Ampere Cat. No. $ Price Cat. No. $ Price 10 k AIR 10 k AIR 10 k AIR Ratingc 15 QO115CAFI 282.00 QO115VHCAFI 534.00 Combination Arc-fault 1 Space Required 2 Spaces Required 3 Spaces Required Interrupter 20 QO120CAFI 282.00 QO120VHCAFI 534.00 Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price QO-GFI 15 QO115HIDb 38.10 QO215HID 87.00 QO315HID 300.00 ® 20 QO120HIDb 38.10 QO220HID 87.00 QO320HID 300.00 Qwik-Gard circuit breakers provide overload and short 25 QO125HID 38.10 QO225HID 87.00 QO325HID 300.00 circuit protection, combined with Class A ground fault 30 QO130HID 38.10 QO230HID 87.00 QO330HID 300.00 protection. Class A denotes a ground fault circuit 40 QO140HID 38.10 QO240HID 87.00 —— interrupter that will trip when a fault current to ground is 6 50 QO150HID 38.10 QO250HID 87.00 —— mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to QO-K 1P prevent nuisance tripping. QO-GFI Key operated QO circuit breakers are available in single- pole construction and can be mounted in any single-pole Table 1.7: QO-GFI Circuit Breakers space which will accept a standard QO. These circuit Qwik-Gard Circuit Breakers breakers can be turned ON or OFF or to RESET with a With Ground Fault Circuit Interrupter special key (catalog number QOK10) included with the 2P Common Trip circuit breaker. These circuit breakers are UL Listed and 1P 120 Vac 120/240 Vac Ampere available as shown in the table. Ratingc 10 k AIR 22 k AIR 10 k AIR Table 1.11: QO-K Circuit Breakers 1 Space Required 1 Space Required 2 Spaces Required 2P Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 120 Vac—10 k AIR (1 Space Required) QO-GFI 15 QO115GFI 233.00 QO115VHGFI 482.00 QO215GFI 413.00 Ampere Cat. No. $ Price 20 QO120GFI 233.00 QO120VHGFI 482.00 QO220GFI 413.00 Ratingc 25 QO125GFI 233.00 QO125VHGFI 482.00 QO225GFI 413.00 10 QO110K 164.00 30 QO130GFI 233.00 QO130VHGFI 482.00 QO230GFI 413.00 15 QO115K 164.00 40 — — — — QO240GFI 413.00 20 QO120K 164.00 50 — — — — QO250GFI 413.00 25 QO125K 164.00 60 — — — — QO260GFId 413.00 30 QO130K 164.00 QO-EPD QO-HM QO-EPD circuit breakers provide overload and short circuit High magnetic trip circuit breakers are recommended for protection combined with Class B ground fault protection. applications where high initial inrush may occur and for They are designed to provide ground fault protection of individual dimmer applications. equipment at a 30 milliampere level. They are not Table 1.12: QO-HM Circuit Breakers designed to protect people from electrical shock. 1P Ampere Ratingc Table 1.8: QO-EPD Circuit Breakers QO-K Key Cat. No $ Price Operated 120 Vac—10 k AIR 1P 2P Common Trip 120 Vac 120/240 Vac 15 A QO115HMab 30.60 20 A QO120HMab 30.60 Ampere 10 k AIR 10 k AIR Ratingc 1 Space Required 2 Spaces Required Non-automatic (Standard) Miniature Switches Cat. No. $ Price Cat. No. $ Price Miniature non-automatic switches have the same physical 15 QO115EPD 410.00 QO215EPD 660.00 packaging as miniature circuit breakers, but open only 20 QO120EPD 410.00 QO220EPD 660.00 when the handle is switched to the OFF position. QO 25 QO125EPD 410.00 QO225EPD 660.00 Non-automatic switches provide no overcurrent protection 1P 30 QO130EPD 410.00 QO230EPD 660.00 or short circuit protection. They must not be used on With Shunt Trip 40 — — QO240EPD 660.00 systems that have an available fault current greater than 50 — — QO250EPD 660.00 the values listed in the table. 60 — — QO260EPDd 660.00 Non-automatic switches are UL Listed per UL 1087 and QO-SWN are CSA certified. ® Switch Neutral Common Trip 2008 NEC 514.11 Table 1.13: QO Non-Automatic Miniature Switches, 240 Vac 10 kA Table 1.9: QO-SWN Circuit Breakers 2P 3P Ampere 2 Wire 120 Vac 3 Wire 120/240 Vac Two-wire Rating Cat. No. $ Price Cat. No. $ Price 10 k AIR 10 k AIR QO-SWN Ampere 60 QO200 70.00 QO300 248.00 Ratingc 2 Spaces Required 3 Spaces Required 100 QO2000 200.00 QO3000 366.00 Cat. No. $ Price Cat. No. $ Price a UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked 10 QO210SWN 95.00 QO310SWN 143.00 for use with HACR type circuit breakers. 15 QO215SWN 95.00 QO315SWN 143.00 b UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac 20 QO220SWN 95.00 QO320SWN 143.00 fluorescent lighting loads. o o 25 QO225SWN 95.00 QO325SWN 143.00 c 10–30 A circuit breakers are suitable for use with 60 C or 75 C o conductors. 35–60 A circuit breakers are suitable for use with 75 C 30 QO230SWN 95.00 QO330SWN 143.00 conductors. 40 QO240SWN 95.00 QO340SWN 143.00 Three-wire d Suitable only for feeding 240 Vac and 208 Vac loads. Does not contain 50 QO250SWN 95.00 QO350SWN 143.00 load neutral connection. QO-SWN Interrupting Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-12 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-53 © 2009 Schneider Electric Discount 1-3 DE2A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® QO Miniature Circuit Breakers Accessories Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.14: Accessories for use with QO and QOB Miniature Circuit Breakers Description Cat. No. $ Price Schedule Handle Attachments Handle Tie: Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P QO1HT 3.80 DE2E Converts any two adjacent 120/240 Vac1P side-by-side QOT circuit breakers to independent trip 2P QOTHT 3.80 DE2E Handle Clamp: Clamp for holding QO 1P handle in ON or OFF position QO1LO 3.80 DE2E Clamp for holding QO or Q1 either 1P, 2P or 3P circuit breaker handles in ON or OFF position HLO1 9.90 DE2E For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment QOHPL 9.90 DE2E Fixed attachment QO1PA 10.70 DE2E For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position QOTHPA 11.10 DE2E Handle Padlock Attachment: for Padlocking in ON or OFF position For padlocking 2P QO-GFI circuit breakers in either ON or OFF position, fixed attachment. GFI2PA 9.20 DE2A For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment QO1HPL 10.70 DE2E Fixed attachment QO1PL 10.70 DE2E For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. QO1PAF 43.50 DE2E For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. QO2PAF 25.80 DE2E Handle Padlock Attachment: for Padlocking in OFF position For padlocking 1P QO-GFI, QO-AFI and QO-EPD circuit breakers in OFF position only, fixed attachment. QOGFI1PAF 51.00 DE2E For padlocking 2P QO-GFI and QO-EPD circuit breakers in OFF position only, fixed attachment. QOGFI2PAF 38.40 DE2E Ring Terminal Ring terminals are available as a factory-installed option. See page 7-10 +20% Price Adder DE2A Sub-feed Lugs 60 A 2P plug-on – 2 spaces required (6–2 Al/Cu) QO60SL 47.10 DE2A 125 A 2P plug-on – 2 spaces required (12–2/0 Al/Cu) QO2125SL 137.00 DE2A 225 A 2P plug-on – 4 spaces required (4–300 Al/Cu) QO2225SLa 308.00 DE2A 125 A 3P plug-on – 3 spaces required (12–2/0 Al/Cu) QO3125SL 137.00 DE3 For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted Mechanical Interlock Attachment QO2DTI 24.90 DE2E side-by-side so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed With Retaining Kit: circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO QO2DTIM 63.00 DE2E circuit breakers in QO816L100 load centers. a Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater. QO1HT QO1PA HLO1 QO1PL QO1PAF QO1LO QOGFI2PAF QO2DTI QOTHPA QO2PAF QO1HPL QOHPL Factory-Installed Accessories for use with QO and QOB Miniature Circuit Breakers ® Factory-installed electrical accessories take up an additional pole space on QO , QO-GFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factory- installed accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers or on QO2150, QO2175, or QO2200 circuit breakers. Table 1.15: Factory-Installed Accessories Rated Coil Cat. No. $ Price Contact Max. Max. Cat. No. $ Price Accessory Description Accessory Description Voltage Burden Suffix Adder Comb. Voltage Load Suffix Adder 12 Vac/Vdc 60 VA -1042 189.00 24 Vac/Vdc 168 VA Monitors circuit breaker contact status and provides a remote signal indicating the circuit Trips the circuit breaker from a 120 Vac 72 VA breaker contacts are OPEN or CLOSED. remote location by means of a trip 208 Vac 228 VA -1021 189.00 coil energized from a separate 240 Vax 288 VA Application Auxiliary 1A 120 Vac 5 A -1200 132.00 circuit. A 120 Vac shunt trip will Switches 1B 120 Vac 5 A -1201 132.00 operate at 55% or more of ratedAuxiliary switch terminals accept voltage. All other shunt trips will (2) 14–12 AWG Cu leads. operate at 75% or more of rated Leads (EH): Yellow for “A’’, Blue for voltage. “B’’, Striped common 18 AWG Cu. Shunt Trip Application For use with momentary or Used with control circuits and is actuated only maintained push button. when the circuit breaker has tripped. Standard Not available on QO-GFI, construction includes a normally-open QO-EPD. contact. Alarm 1A 120 Vac 5 A -2100 132.00Shunt trip terminals accept Switches Application (2) 0.14– 0.12 AWG Cu. Leads: Alarm switch terminals accept (2) 14–12 AWG Cu leads. © 2009 Schneider Electric 1-4 Discount DE2 DE2A DE2E DE3 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® QO Load Centers Indoor-1Ø, Main Lug Class 736, 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W Load Centers, 120/240 Vac, UL Listed Table 1.16: Main Lugs (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI, and QO-PL branch circuit breakers from pages 1-2 and 1-3) Load Center Indoor Cover with Door Main Wire Size Equipment Ground Bar Max. $ Price Box No. Box and Interior (Order Separately) AWG/kcmil Kit (Order Separately) Mains Max. 1P Tandem (Interior, Spaces See Page Rating Circuitsa Circuit Box and Flush Surface 1-17 Cat. No. $ Price $ Price Al Cu Cat. No. $ Price Breakers Cover) Cat. No. Cat. No. Fixed Mains—Factory-Installed Main Lugs—10 kA Short Circuit Current Ratingb 30 A 2 2 0 41.70 QO2L30Scd 41.70 12–10 14–10 PK3GTA1 11.40 1 70 A 2 4 2 69.00 QO24L70F/Sef 69.00 Cover Included—Without Door 12–3 14–4 PK4GTA 10.80 2 87.00 QO612L100F/Seg 87.00 8–1 PK7GTA 11.70 4 612 6 90.00 QO612L100DF/Seg 90.00 Cover Included—With Door 8–1 PK7GTA 11.70 4 100 A 131.00 QO816L100F/Seg 131.00 Cover Included—Without Door 816 8 8–1 PK7GTA 11.70 4 143.00 QO816L100DF/Seg 143.00 Cover Included—With Door 612 6 111.00 QO612L100DFCU/SCUegh 111.00 Cover Included—With Door 8–1 PK7GTA 11.70 4 100 A 816 8 174.00 QO816L100DFCU/SCUegh 174.00 Cover Included—With Door 8–1 PK7GTA 11.70 4 125 A 4 8 4 93.00 QO148L125GF/Sei 93.00 Cover Included—Without Door 12–2/0 14–2/0 PK7GTAl 21 Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Cu Busbj 12 12 0 196.70 QO112L125G 159.00 QOC16UF QOC16US 37.70 PK9GTAl 6 12 24 12 235.70 QO11224L125G 198.00 QOC16UF QOC16US 37.70 PK15GTAl 6 16 16 0 255.70 QO116L125G 218.00 QOC24UF QOC24US 37.70 PK12GTAl 7 16 24 8 300.70 QO11624L125G 263.00 QOC24UF QOC24US 37.70 PK15GTAl 7 125 A 6–2/0 20 20 0 271.70 QO120L125G 234.00 QOC24UF QOC24US 37.70 PK15GTAl 7 I 20 24 4 370.70 QO12024L125G 333.00 QOC24UF QOC24US 37.70 PK15GTAl 7 N 24 24 0 381.70 QO124L125G 344.00 QOC24UF QOC24US 37.70 PK15GTAl 7 D O 32 32 0 434.60 QO132L125G 395.00 QOC32UF Use Flush 39.60 PK23GTA, LK100ANl 8 O Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating , QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Cu Busbj R 20 30 10 419.00 QO12030L150G 332.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 9 150 A 24 24 0 431.00 QO124L150G 344.00 QOC30UF QOC30US 87.00 6–250 PK15GTAl 9 30 30 0 437.00 QO130L150G 350.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 9 12 12 0 353.00 QO112L200G 266.00 QOC30UF QOC30US 87.00 PK15GTAl 9 24 36 12 819.00 QO12436L200TFTk 732.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl 10 30 30 0 494.00 QO130L200G 407.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 9 200 A 30 40 10 554.00 QO13040L200G 467.00 QOC30UF QOC30US 87.00 6–250 PK23GTA, LK100ANl 9 40 40 0 746.00 QO140L200G 659.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl 10 New! 40 60 20 944.00 QO14060L200G 857.00 QOC40UF QOC40US 87.00 (2) PK15GTAl 10 42 52 10 921.00 QO14252L200G 810.00 QOC42UF QOC42US 111.00 (2) PK15GTAl 11 225 A 42 42 0 828.00 QO142L225G 717.00 QOC42UF QOC42US 111.00 6–300 PK23GTA, LK100ANl 11 Fixed Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Ratingbj QONQ30LS400 (Int) 1080.00 (1) 1/0–750 400 A 30 30 0 1641.00 NC50NQVF NC50NQVS 486.00 15 PK27GTAn 33.80 MH50 (box)o 75.00 or (2) 1/0–300 or QONQ42LS400 (Int)m 1185.00 (1) 1/0–750 PK15GTA6 53.00 400 A 42 42 0 1746.00 NC50NQVF NC50NQVS 486.00 15 MH50 (box) 75.00 or (2) 1/0–300 Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. ® c Will not accept QO-EPD or Qwik-Gard QO-GFI or QO-AFI circuit breakers. d Mains rated 25 A when Al wire is used. e Order F for flush device or S for surface device. f Use 10 AWG maximum size wire for GFI and AFI circuit breakers. g 70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker. h CU indicates copper bus. i Copper bus. j UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. k Supplied with feed-thru lugs. l Factory-included. m Interior only, order box separately. QO816L100F or S n PK27GTA includes a 6–2/0 AWG Al/Cu lug. o PE1A Discount Schedule. QO120L125G without cover Main Circuit Breaker Kits Table 1.17: Field-Installed Main Circuit Breaker (Use with Convertible Load Centers Only) QOM1 Frame Size QOM2 Frame Sizes 22 k AIRq 22 k AIRq Main Circuit Convertible Main Circuit Convertible Lug Wire Sizer Lug Wire Sizer Breaker Load Center Breaker Load Center Main Circuit Main Circuit AWG/kcmil AWG/kcmil $ Price $ Price Ratingp Mains Rating Ratingp Mains Rating Breaker Breaker 50 A 100–125 QOM50VH 140.00 100 A 150–225 QOM2100VH 468.00 60 A 100–125 QOM60VH 140.00 125 A 150–225 QOM2125VH 468.00 QOM1 Frame Size 70 A 100–125 QOM70VH 140.00 150 A 150–225 QOM2150VH 468.00 4–300 Al or Cu 50–125 Amperes 80 A 100–125 QOM80VH 201.00 175 A 200–225 QOM2175VH 468.00 12–2/0 Al or Cu 90 A 100–125 QOM90VH 201.00 200 A 200–225 QOM2200VH 468.00 100 A 100–125 QOM100VH 201.00 225 A 225 QOM2225VH 468.00 110 A 125 QOM110VH 468.00 125 A 125 QOM125VH 468.00 p Do not exceed the load center mains rating. q 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. r Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. s Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00. QOM2 Frame Size 100–225 Amperes © 2009 Schneider Electric Discount 1-5 DE3A PE1A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® QO Load Centers Indoor, 1Ø Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W—120/240 Vac—UL Listed Table 1.18: Indoor Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL Branch Circuit Breakers from pages 1-2 and 1-3.) Indoor Cover with Door Equipment Max. Max. $ Price Main Box No. Load Center (Order Separately) Ground Bar Kit Mains Single Tandem (Interior, Wire Size See Box and Interior Spaces (Order Separately) Rating Pole Circuit Box and AWG/kcmil Page Flush Surface $ Price Circuitsa Breakers Cover) Al or Cu 1-17 Cat. No. $ Price Cat. No. Cat. No. Cat. No. $ Price Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating, Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),b QOM1 Main Circuit Breaker Frame Size—Copper Bus 12 12 0 339.70 QO112M100 302.00 QOC12UF QOC12US 37.70 PK9GTA 13.40 5 16 16 0 379.70 QO116M100 342.00 QOC20U100F QOC20U100S 37.70 6–1 PK12GTA 15.80 6 100 A 20 20 0 433.70 QO120M100 396.00 QOC20U100F QOC20U100S 37.70 PK15GTA 17.10 6 24 24 0 553.70 QO124M100 516.00 QOC24UF QOC24US 37.70 PK15GTA 17.10 7 6–2/0 32 32 0 726.70 QO132M100 689.00 QOC32UF Use Flush 37.70 PK18GTA 18.80 8 24 24 0 819.70 QO124M125 782.00 QOC24UF QOC24US 37.70 PK15GTA 17.10 7 125 A 6–2/0 32 32 0 1041.60 QO132M125 1002.00 QOC32UF Use Flush 39.60 PK18GTA 18.80 8 Convertible Mains —Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5) b QOM2 Main Circuit Breaker Frame Size—Copper Bus 20 30 10 821.00 QO12030M150 734.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9 24 24 0 849.00 QO124M150 762.00 QOC30UF QOC30US 87.00 PK15GTA 17.10 9 150 A 4–250 30 30 0 854.00 QO130M150 767.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9 I 32 32 0 969.00 QO132M150 882.00 QOC40UF QOC40US 87.00 PK18GTA 18.80 10 N D 20 40 20 821.00 QO12040M200 734.00 QOC30UF QOC30US 87.00 PK23GTA 21.30 9 O 24 24 0 866.00 QO124M200 779.00 QOC30UF QOC30US 87.00 PK15GTA 17.10 9 O PK23GTA and R 24 36 12 1287.00 QO12436M200TFTh 1200.00 QOC40UF QOC40US 87.00 10 LK100ANg 4–250 30 30 0 879.00 QO130M200 792.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9 200 A 30 40 10 957.00 QO13040M200 870.00 QOC30UF QOC30US 87.00 PK23GTA 21.30 9 40 40 0 1121.00 QO140M200 1034.00 QOC40UF QOC40US 87.00 PK23GTA 21.30 10 40 60 20 1431.00 QO14060M200 1344.00 QOC40UF QOC40US 87.00 PK23GTA 21.30 10 42 42 0 1220.00 QO142M200 1109.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11 New! 42 52 10 1382.00 QO14252M200 1271.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11 4–300 40 40 0 1196.00 QO140M225 1085.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11 225 A 42 42 0 1253.00 QO142M225 1142.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11 Fixed Mains—Factory-installed LAL Main Circuit Breaker, 42 kA Short Circuit Current Ratingc QONQ42MS300 4243.00 (1) 4–500 (int)d 300 A 42 42 0 4909.00 NC62NQVF NC62NQVS 591.00 16 PK27GTAe 33.80 MH62 (box)f 75.00 or (2) 4–3/0 or QONQ42MS400 PK15GTA6 53.00 4243.00 (1) 4–500 (int)d 400 A 42 42 0 4909.00 NC62NQVF NC62NQVS 591.00 16 MH62 (box)f 75.00 or (2) 4–250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. c UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H circuit breakers only. d Interior only, order box separately. e PK27GTA includes a 6–2/0 Al/Cu lug. f PE1A Discount Schedule. g Factory included. h Supplied with feed-thru lugs. Main Lug Kits Table 1.19: Field-Installed Main Lugs (Convertible Load Centers Only) Use on Lug Wire Sizej Main Lug Convertible Load Center Cat. No. $ Price AWG/kcmil Ratingi with Mains Rating Al or Cu 125 A 100–125 A QOL125k 44.10 6–2/0 225 A 150–225 A QOL225k 104.00 6–300 i Do not exceed the load center mains rating. j Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under main wire size. k If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13. QOL125 QOL225 QO130M150 © 2009 Schneider Electric 1-6 Discount DE3A PE1A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® QO Load Centers Rainproof 1Ø, Main Lugs, Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W—120/240 Vac—UL Listed Table 1.20: Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 1-2 and 1-3.) Main Equipment Max. $ Price Load Center Max. Box No. Wire Size Ground Bar Kit Mains Tandem (Interior, Box and Interior Spaces Single Pole See AWG/kcmil (Order Separately) Rating Circuit Box and Circuitsa Page 1-17 Breakers Cover) Cat. No. $ Price Al Cu Cat. No. $ Price Non-Metallic Enclosure Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating 60 A 2 4 2 102.00 QO24L60NRNM 102.00 14–4 14–4 Factory-installed — 1NM Metallic Enclosure Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating 40 A 2 2 0 113.00 QO2L40RBb 113.00 12–6 14–6 PK3GTA1 11.40 1R 70 A 2 4 2 131.00 QO24L70RBb 131.00 12–3 14–4 PK4GTA 10.80 1R 612 6 143.00 QO612L100RBc 143.00 PK7GTA 11.70 2R 100 A 612 6 158.00 QO612L100TRBc 158.00 8–1 Factory-installed — 2R 816 8 231.00 QO816L100RBc 231.00 PK7GTA 11.70 2R 612 6 174.00 QO612L100RBCUcd 174.00 PK7GTA 11.70 2R 100 A 8–1 R 816 8 279.00 QO816L100RBCUcd 279.00 PK7GTA 11.70 2R A 125 A 4 8 4 152.00 QO148L125GRBd 152.00 12–2/0 14–2/0 PK7GTA Factory-included 15R I N Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg P QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus R 12 12 0 285.00 QO112L125GRB 285.00 PK9GTA Factory-included — 3R O O 12 24 12 365.00 QO11224L125GRB 365.00 PK15GTA Factory-included — 3R 125 A 6–2/0 F 16 24 8 435.00 QO11624L125GRB 435.00 PK15GTA Factory-included — 4R 24 24 0 522.00 QO124L125GRB 522.00 PK15GTA Factory-included — 4R Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus 150 A 30 30 0 587.00 QO130L150GRB 587.00 4–250 PK23GTA, LK100AN Factory-included 6R 12 12 0 480.00 QO112L200GRB 480.00 PK9GTA Factory-included 5R 30 30 0 666.00 QO130L200GRB 666.00 PK23GTA, LK100AN Factory-included 6R 30 40 10 714.00 QO13040L200GRB 714.00 PK23GTA, LK100AN Factory-included 6R 200 A 4–250 40 40 0 971.00 QO140L200GRB 971.00 PK23GTA, LK100AN Factory-included 7R New! 40 60 20 1262.00 QO14060L200GRB 1262.00 (2) PK15GTA, (1) LK100AN Factory-included 7R 42 52 10 1194.00 QO14252L200GRB 1194.00 (2) PK15GTA, (1) LK100AN Factory-included 8R 225 A 42 42 0 1310.00 QO142L225GRB 1310.00 4–300 PK23GTA, LK100AN Factory-included 8R 1Ø3W—120/240 Vac—UL Listed Table 1.21: Main Circuit Breaker Order QO, QOT, QO-GFI, QO-AFI, QO-EPD and QO-PL branch circuit breakers from pages 1-2 and 1-3. Equipment Max. $ Price Main Load Center Max. Box No. Ground Bar Kit Mains Tandem (Interior, Wire Size Box and Interior Spaces Single Pole See (Order Separately) Rating Circuit Box and AWG/kcmil Circuitsa Page 1-17 Breakers Cover) Al or Cu Cat. No. $ Price Cat. No. $ Price Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating —Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg QOM1 Main Circuit Breaker Frame Size—Copper Bus 12 12 0 461.00 QO112M100RB 461.00 PK9GTA 13.40 3R 100 A 16 16 0 504.00 QO116M100RB 504.00 6–2/0 PK12GTA 15.80 4R 20 20 0 552.00 QO120M100RB 552.00 PK15GTA 17.10 4R 125 A 24 24 0 954.00 QO124M125RB 954.00 6–2/0 PK15GTA 17.10 4R Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating —Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg R QOM2 Main Circuit Breaker Frame Size—Copper Bus A 20 30 10 953.00 QO12030M150RB 953.00 PK18GTA 18.80 5R I 150 A 4–250 N 30 30 0 1122.00 QO130M150RB 1122.00 PK18GTA 18.80 6R P 20 40 20 954.00 QO12040M200RB 954.00 PK23GTA 21.30 5R R 30 30 0 1154.00 QO130M200RB 1154.00 PK18GTA 18.80 6R O O 30 40 10 1179.00 QO13040M200GRB 1179.00 PK23GTA 21.30 6R F 200 A 40 40 0 1397.00 QO140M200RB 1397.00 4–250 PK23GTA 21.30 7R 40 60 20 1815.00 QO14060M200RB 1815.00 PK15GTA 17.10 7R 42 42 0 1469.00 QO142M200RB 1469.00 PK23GTA 21.30 8R New! 42 52 10 1718.00 QO14252M200RB 1718.00 PK15GTA 17.10 8R 225 A 42 42 0 1631.00 QO142M225RB 1631.00 4–300 PK23GTA 21.30 8R QOM1/QOM2 Feed-Thru Main Circuit Breaker With Feed-Thru Lugs—Copper Bus, 22 kA Short Circuit Current Ratingh 125 A 6 12 6 620.00 QO1612M125FTRBi 620.00 4–2/0 PK12GTA 15.80 3R 150 A 8 16 8 863.00 QO1816M150FTRBi 863.00 4–250 PK15GTA-L 35.00 6R 200 A 8 16 8 863.00 QO1816M200FTRBi 863.00 4–250 PK15GTA-L 35.00 6R Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Use 10 AWG maximum size wire for AFI and GFI circuit breaker. c 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. d Copper bus. e UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. f UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. g Side hinge door device; allow 1-1/4 in. on left side for door to open. h 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22 kA available fault current. i QO1612M125FTRB provided with QOM1 frame main circuit breaker. QO1816M150FTRB and QO1816M200FTRB provided with QOM2 frame main circuit breaker. © 2009 Schneider Electric Discount 1-7 DE3A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® QO Load Centers 3Ø, Main Lugs, Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.22: 3Ø4W 208Y/120 Vac, 3Ø4W 240/120 Vac Delta and 3Ø3W 240 Vac Delta, UL Listed. (Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 1-2 and 1-3.) Max. Indoor Cover with Door Main Equipment $ Price Load Center Box No. Number (Order Separately) Wire Size Ground Bar Kit Mains (Interior, Box and Interior See of 1P QO AWG/kcmil (Order Separately) Rating Box and Pages Flush Surface circuit $ Price Cover) 1-17 Cat. No. $ Price Cat. No. Cat. No. Al Cu Cat. No. $ Pricej breakers Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratinga 60 A 3 107.00 QO403L60NF/S 107.00 Cover Included With Load Center (No Door) — 10–6 PK4GTA 7.20 13 i 12 369.70 QO312L125Gh 332.00 QOC16UF QOC16US 37.70 Factory-incl.g —6 i 125 A 20 508.70 QO320L125Gh 471.00 QOC24UF QOC24US 37.70 6–2/0 6–2/0 Factory-incl.g —7 i 24 577.70 QO324L125Gh 540.00 QOC24UF QOC24US 37.70 Factory-incl.g —7 i 18 530.00 QO318L200Gh 443.00 QOC30UF QOC30US 87.00 Factory-incl.f —9 200 A 6–250 6–250 I i 30 707.00 QO330L200Gh 620.00 QOC30UF QOC30US 87.00 Factory-incl.f —9 N i 225 A 42 953.00 QO342L225Gh 842.00 QOC42UF QOC42US 111.00 6–300 6–300 Factory-incl.f —11 D O Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingb O i 100 A 27 1058.00 QO327M100c 971.00 QOC30UF QOC30US 87.00 4–2/0 4–2/0 PK15GTA 17.10 9 R 125 A 30 1931.00 QO330MQ125dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12 30 1931.00 QO330MQ150dh 1839.00 QOC342MQF QOC342MQS 92.00 PK18GTA 18.80 12 150 A 4–300 4–300 42 2119.00 QO342MQ150dh 2027.00 QOC342MQF QOC342MQS 92.00 PK23GTA 21.30 12 30 1931.00 QO330MQ200dh 1839.00 QOC342MQF QOC342MQS 92.00 PK18GTA 18.80 12 200 A 4–300 4–300 42 2119.00 QO342MQ200dh 2027.00 QOC342MQF QOC342MQS 92.00 PK23GTA 21.30 12 225 A 42 2119.00 QO342MQ225dh 2027.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK23GTA 21.30 12 Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratingae 60 A 3 177.00 QO403L60NRB 177.00 —10–6 PK4GTA 10.80 10R 12 485.00 QO312L125GRB 485.00 Factory Incl.g —3R 125 A 6–2/0 6–2/0 20 629.00 QO320L125GRB 629.00 Factory Incl.g —4R R Cover Included 18 618.00 QO318L200GRB 618.00 Factory Incl.f —6R A 200 A 6–250 6–250 I 30 839.00 QO330L200GRB 839.00 Factory Incl.f —6R N 225 A 42 1494.00 QO342L225GRB 1494.00 6–300 6–300 Factory Incl.f —8R P Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingbe R O 100 A 27 1185.00 QO327M100RBc 1185.00 4–2/0 4–2/0 PK15GTA 17.10 6R O 125 A 30 2147.00 QO330MQ125RBd 2147.00 4–300 4–300 PK18GTA 18.80 14R F 150 A 30 2147.00 QO330MQ150RBd 2147.00 4–300 4–300 PK18GTA 18.80 14R Cover Included 30 2147.00 QO330MQ200RBd 2147.00 PK18GTA 18.80 14R 200 A 4–300 4–300 42 2333.00 QO342MQ200RBd 2333.00 PK23GTA 21.30 14R 225 A 42 2333.00 QO342MQ225RBd 2333.00 4–300 4–300 PK23GTA 21.30 14R Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. b 25 kA short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k AIR branch circuit breakers. c Includes factory-installed back fed QO3100VH main circuit breaker. d 65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers. e Side hinge door device allow 1-1/4 in. on left side for door to open. f PK23GTA and LK100AN. g PK15GTA. h For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating when QODX...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used). i DE3A Discount Schedule j DE2 Discount Schedule Table 1.23: 3Ø Main Circuit Breakers Field-installed alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A. Do not exceed the load center main rating. Amperage 25 k AIR 65 k AIR 100 k AIRk 70 A QDL32070 QGL32070 QJL32070 80 A QDL32080 QGL32080 QJL32080 90 A QDL32090 QGL32090 QJL32090 100 A QDL32100 QGL32100 QJL32100 110 A QDL32110 QGL32110 QJL32110 125 A QDL32125 QGL32125 QJL32125 150 A QDL32150 QGL32150 QJL32150 175 A QDL32175 QGL32175 QJL32175 200 A QDL32200 QGL32200 QJL32200 225 A QDL32225 QGL32225 QJL32225 $ Price (DE2) 1784.00 2442.00 2796.00 k When these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating is 65 kA at 240 Vac and 100 kA at 208 Vac. Table 1.24: 3Ø Main Lug Kits Field-installed main lugs for convertible 3Ø main circuit breaker load centers. Main Lug Lug Wire Size Cat. No. $ Price QO342MQ200 Amperage Rating AWG/kcmil QO312L125G 125 A QOL3125 67.00 6–2/0 Cu/Al 225 A QOL3225 158.00 6–300 Cu/Al © 2009 Schneider Electric 1-8 Discount DE3 DE3A DE2 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ON ON OFF OFF ® ® QO and Homeline Load Centers Backup Power Solutions Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.25: Order QO, QOT, QO-EPD, QO-GFI, and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3. Main Box No. Load Center Equipment Grounding Bar Kit Mains Max. Single Max. Wire Size See Box, Interior and Cover (Order Separately) Rating Spaces Pole Tandem Circuit AWG/kcmil Page (A) Circuits a Breakers 1-12 Cat. No. $ Price Cat. No. $ Price Al Cu Generator Panels for Sub-Feed Applications Type 1 (Indoor) 1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating I N 30 4 8 4 QO48M30DSGP 563.00 14–8 14–8 4 D O PK7GTA 11.70 60 4 8 4 QO48M60DSGP 563.00 8–2 8–2 4 O R Generator Panels with Power Inlet Plug for Sub-Feed Applications Type 3R (Outdoor) 1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating R A 48 4 QO1DM10020TRBR 848.00 — — I 48 4 QO1DM10030TRBR 848.00 —— N P 100 Factory-Installed 8–2 R O 48 4 QO1DM10050TRBR 1148.00 —— O F Generator Panel—Automatic Transfer Switch (Contact your local Square D Field Sales office for more information.) b 1-Phase 3-Wire 120/240 Vac Factory- or Field-Installed Main Circuit Breaker 22,000 RMS Sym. Ampere Short Circuit Current Rating 150 38 42 42 QO13842MX150 1349.00 PK23GTA 21.30 4–250 4–250 12 200 38 42 42 QO13842MX200 1499.00 PK23GTA 21.30 4–250 4–250 12 I N 38 42 42 QO13842MX225 1649.00 4–250 4–250 12 225 PK23GTA 21.30 D 38 42 42 QO13842UX225 c 1199.00 4–250 4–250 12 O QOC38MXUF (Cover) 149.00 — O R 150 14 28 28 QO11428MX150FTRBde 1349.00 PK23GTA 21.30 4–250 4–250 7R 14 28 28 QO11428MX200FTRBde 1499.00 PK23GTA 21.30 4–250 4–250 7R 200 14 28 28 QO11428UX200FTRBcde 1199.00 PK23GTA 21.30 4–250 4–250 7R QO Load Center Accessories Cat. No. $ Price Schedule For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that QO2DTI 24.90 DE2E only one circuit breaker can be “ON’’ at a time. QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual QO2DTIM 63.00 DE2E power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back- Manual Transfer Equipment Kit PK4DTIM4LA 102.00 DE3A up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back- PK4DTIM4HA 102.00 DE3A up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up PK4DTIM4LAL 102.00 DE3A power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P QOCRBGK1 105.00 DE3A main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. Generator Circuit Breaker For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main QOCGK2 105.00 DE3A Interlock Kit circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) QORBGK2 105.00 DE3A with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b One main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max.) ordered separately. Automatic Transfer Switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor. c Universal mains – No factory-installed main circuit breaker or main lugs. QOM2 frame size, field-install 22 k AIR. Main circuit breaker or main lugs (see pages 1-5 or 1-6). d Supplied with feed-thru lugs. e Device is rated NEMA 3R and can be used for indoor or outdoor applications. QO2DTI Installed QO2DTI PK4DTIM4HA QOCGK2 Installed © 2009 Schneider Electric Discount 1-9 DE3A All Rights Reserved Schedule Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5 3 1 ON ON OFF OFF LOAD CENTERS 1 LOAD CENTERS 1 ® QO Load Centers Special Applications Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.26: QO Special Application (Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.) Load Center b Equipment Ground Bar Kit Main Wire Size Mains Short Circuit Max. Tandem Box No. Max. 1P Box, Interior, and Cover (Order Separately) AWG/kcmil Rating Current Spaces Circuit See Circuits a Rating Breakers Page 1-17 Cat. No. $ Price Cat. No. $ Price Al Cu Manufactured Housing: 1Ø2W 120 Vac—Main Lugs Only—CSA Certified 30 Ac 10 kA 2 0 QO2L30TTSd 51.00 12–10 14–10 1 2 Factory-installed 4 50 A 10 kA 2 2 QO24L50TTSe 78.00 —14–6 2 1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified 30 A 10 kA 3 5 2 QO35FM30TTF/S 83.00 Factory-installed f 3 1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified 70 A 10 kA 2 4 2 QO24L70TSe 78.00 12–3 14–4 2 10 kA 6 12 6 QO612L100TF/Sg 86.00 4 Factory 10 kA 6 12 6 QO612L100DTF/Sg 101.00 4 Installed 100 A 4–1 10 kA 8 16 8 QO816L100TF/Sg 137.00 4 10 kA 8 16 8 QO816L100DTF/Sg 159.00 4 Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package Convertible Mains—Factory-Installed Main Lugsi—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus 65 kA 12 0 QO112L125GC 188.00 PK12GTA Incl. 6–2/0 6 12 I 125 A 65 kA 12 24 12 QO11224L125GC 249.00 PK15GTA Incl. 6–2/0 6 N 20 65 kA 20 0 QO120L125GC 284.00 PK15GTA Incl. 6–2/0 7 D O Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus O 150 A 65 kA 30 30 0 QO130L150TC 452.00 PK23GTA, LK100AN Installed 6–250 9 R 200 A 65 kA 30 40 10 QO13040L200GC 575.00 PK23GTA, LK100AN Incl. 6–250 9 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Busj 22 kA 12 12 0 QO112M100C 351.00 PK9GTA 13.40 4–1/0 5 22 kA 12 20 8 QO11220M100C 413.00 PK15GTA 17.10 4–1/0 5 100 A 22 kA 16 16 0 QO116M100C 395.00 PK12GTA 15.80 4–1/0 6 22 kA 20 20 0 QO120M100C 446.00 PK15GTA 17.10 4–1/0 6 125 A 22 kA 32 32 0 QO132M125C 1041.00 PK18GTA 18.80 6–2/0 8 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Busj 22 kA 20 30 10 QO12030M150C 843.00 PK18GTA 18.80 4–250 9 150 A 22 kA 30 30 0 QO130M150C 870.00 PK18GTA 18.80 4–250 9 22 kA 20 40 20 QO12040M200C 843.00 PK23GTA 21.30 4–250 9 22 kA 30 30 0 QO130M200C 896.00 PK18GTA 18.80 4–250 9 200 A 22 kA 30 40 10 QO13040M200C 974.00 PK23GTA 21.30 4–250 9 22 kA 40 40 0 QO140M200C 1137.00 PK23GTA 21.30 4–250 10 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Order F for flush device or S for surface device. c Mains rating 25 A when Al wire is used. ® d Will not accept Qwik-Gard QO-GFI or QO-AFI circuit breaker. e Use 10 AWG maximum size wire for GFI and AFI circuit breakers. f Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2. g 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. h UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. i UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. j 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current. Table 1.27: Auxiliary Gutter UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsk. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501 Cat. No. $ Price Cover Conduit Riser Size Width Height Depth SDAG26 338.00 Flush 1-3/4, 2, 2-1/2 or l3 13.50 26.12 3.75 k One tap kit required for each riser wire. l When used with B300 bolt-on hubs. Table 1.28: Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26 Riser Wire Tap Off Wire Use with Auxiliary Cat. N0. $ Price Gutter Cat. No. Lug Type Al/Cu Wire Size Lug Type Al/Cu Wire Size SDGT30020 81.00 SDAG26 Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6–2/0 AWG SDGT300300 120.00 SDAG26 Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6 AWG–300 kcmil Anderson VCEL030516H1 Anderson VCEL02114S1 SDGT300C10C 49.70 SDAG26 (2) 4 AWG–300 kcmil (1) 8–1/0 AWG (Not included) (Not Included) Anderson VCEL030516H1 Anderson VCEL030516H1 SDGT300C300C 70.00 SDAG26 (2) 4 AWG–300 kcmil (1) 4 AWG–300 kcmil (Not included) (Not included) QOGL20 Grounding Terminals 40.70 SDAG26 Mechanical (Included) (2) 6–2/0 AWG — — Discount DE3A © 2009 Schneider Electric 1-10 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® ® QO and Homeline Load Centers Load Center Value Pack Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us Load Center Value Pack Table 1.29: 1Ø3W—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers Equipment Max. Main Box No. Load Center Max. Ground Bar Kit Mains Tandem Wire Size See Box, Interior, Cover and Branch Circuit Breakers 1P (Order Separately) Rating Circuit AWG/kcmil Pages Circuitsa Breakers Al/Cu 1-17 Cat. No. Included Load Center/Circuit Breakers $ Price Cat. No. $ Price QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 1-2 and 1-3. Main Circuit Breaker 100 A 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 839.00 PK18GTA 18.80 4–2/0 8 200 A 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 1103.00 PK23GTA 21.30 4–250 9 200 A 30 40 10 QOVP10 (1) QO13040M200C, (10) QO120 1328.00 PK23GTA 21.30 4–250 9 Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14. Main Lugs 125 A 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 353.00 Included — 6–2/0 6 I N 200 A 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 962.00 Included — 4–250 10 D Main Circuit Breaker O O 100 A 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 528.00 PK15GTA 17.10 4–2/0 7 R 100 A 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 528.00 PK15GTA 17.10 4–2/0 7 150 A 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 983.00 PK23GTA 21.30 4–250 10 200 A 20 40 20 HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230 965.00 Included — 4–250 9 200 A 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 1083.00 Included — 4–250 10 200 A 30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 1083.00 Included — 4–250 10 200 A 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 1328.00 Included — 4–250 10 200 A 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 1328.00 Included — 4–250 10 200 A 40 40 0 HOMVP15 (1) HOM40M200C, (10) HOM120 1346.00 PK23GTA 21.30 4–250 12 R Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14. A Main Circuit Breaker I N P R 200 A 20 40 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 1253.00 PK23GTA 21.30 4–250 6R O O F Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. Riser Panels Table 1.30: 1Ø3W 120/240 Vac—Offset Interior Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interior bc Equipment Main Max. Max. Box No. Load Center Box and Interior Load Center Cover Ground Bar Kit Wire Size Mains Single Tandem Spaces See (Order Separately) AWG/kcmil Rating Pole Circuit Page 1-17 Circuitsd Breakers Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Al Cu Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus 125 A 12 24 12 QO11224L125WG 338.00 QOC20UFWG 53.00 PK15GTA 17.10 6–2/0 14 I 125 A 20 30 10 QO12030L125WG 465.00 QOC20UFWG 53.00 PK15GTA 17.10 6–2/0 14 N D Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating O QOM2 Main Frame Size–Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below–Copper Bus O 200 A 30 40 10 QO13040L200WG 701.00 QOC30UFWG 102.00 PK23GTA 21.30 4–250 23 R Convertible Mains—Factory-installed Main Circuit Breaker—22 kA Short Circuit Current Rating QOM2 Main Frame Size–Convertible to Main Lugs (See page 1-6)—Copper Bus 200 A 24 24 0 QO124M200WG125e 683.00 QOC30UFWG 102.00 PK23GTA 21.30 4–250 23 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. d Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. e Comes with 125 A main circuit breaker factory installed. Panelboard-style Covers for Riser Panels ® Mono-Flat Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used when panel has been converted to a main circuit breaker panel. f Mains Rating of Load Center Cat. No. $ Price 125 A NQC20FWG 117.00 200 A NQC30FWG 180.00 f Order catalog number PK4FL for field-installed lock kit. © 2009 Schneider Electric Discount 1-11 DE3A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Spaces LOAD CENTERS 1 LOAD CENTERS 1 Load Center Accessories QO Load Center Accessories Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.31: QO Load Center Accessories Description Cat. No. $ Price Schedule Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB, PK2MB 7.20 DE3A QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3Ø load centers PK3MB 14.70 DE3A Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers. PK5RK 14.70 DE3A Retaining Kit Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2LA 14.70 DE3A For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2HA 14.70 DE3A For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers QO1SE 3.60 DE3A For use on 1Ø3W, 150 Vac maximum SDSA1175 92.00 DE1B For use on 3Ø4W, 650 Vac maximum SDSA3650 248.00 DE1B Surge Arresters: QO Surgebreaker UL Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. QO2175SB 159.00 DE1B C US Homeline Surgebreaker UL Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. HOM2175SB 159.00 DE1B C US Miscellaneous Surge Arrester UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker QOSAMK 11.40 DE3A Mounting Kit: load centers Replacement Cover 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5 Directory Label: Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 DE5 Stickers: PK2MB QOSAMK PK3MB © 2009 Schneider Electric 1-12 Discount DE1B DE2E DE3A DE5 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® ® Load Center Accessories QO and Homeline Accessories and Voltage testers Class 1130, 6610 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.32: QO Load Center Accessories Description Cat. No. $ Price Schedule Fills opening in covers if twistout is removed in error QOFP 3.60 DE3A Fills main circuit breaker opening in convertible load center covers100–125 A QOM1FP 20.30 DE3A Filler Plates Fills main circuit breaker opening in convertible load center covers150–225 A QOM2FP 20.30 DE3A Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) KFP 20.30 DE3A Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Q2FP 20.30 DE3A Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU, PK8FLa 98.00 DE3A QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP. Lock Kits Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers PK6FL 93.00 DE3A Use with 300 and 400 ampere indoor load centers. PK4FL 90.00 PE1A Field-installed for 12– 2 Al or 14–4 Cu AWG wire LK70AN 10.10 DE3A Field-installed for 6–2/0 Al/Cu AWG wire LK100AN 10.80 DE3A Neutral / Ground Lugs Field-installed for 14–2/0 Al/Cu AWG wire LK125AN 22.10 DE3A Field-installed for 2–3/0 Al/Cu AWG wire LK150AN 32.40 DE3A Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 33.20 DE3A Standard PK15GTA with a 1–4/0 Al/Cu Lug PK15GTAL 35.00 DE3A Standard PK18GTA with a 1–4/0 Al/Cu Lug PK18GTAL 37.80 DE3A Ground Bar Kits Standard PK23GTA with a 1–4/0 Al/Cu Lug PK23GTAL 40.70 DE3A Insulator Kit for PK7GTA through PK27GTA PKGTAB 43.80 DE3A For padlocking main circuit breakers in convertible load centers OFF..........50–125 A, QOM1 Frame Size QOM1PA 11.00 DE2E Handle Padlock Attachment: For padlocking main circuit breakers in convertible load centers OFF..........100–225 A, QOM2 Frame Size QOM2PA 11.00 DE2E a QO403L60NF/S does not have provisions for a field-installed lock. QOFP PKGTAB PK4FL PK6FL and PK8FL Table 1.33: Homeline Load Center Accessories Description Cat. No. $ Price Schedule 50–125 A QOM1PA 11.00 DE2E Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, “OFF” 100–225 A QOM2PA 11.00 DE2E Fills opening in covers if twistout is removed in error HOMFP 3.20 DE3C Filler Plates 100–125 A QOM1FP 20.30 DE3A Fills main circuit breaker opening in convertible load centers 150–225 A QOM2FP 20.30 DE3A Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire LK70AN 10.10 DE3B Field-installed for 6–2/0 AWG Al/Cu wire LK100AN 10.80 DE3B Neutral Lugs Field-installed for 14–2/0 AWG Al/Cu wire LK125AN 22.10 DE3B Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 33.20 DE3A Secures circuit breaker to interior when used as a back-fed main. HOM1RK 6.50 DE3C For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. Secures ONE circuit breaker right side of interior when used as a back-fed main. HOM4RK2LA 14.70 DE3C For 100–125 A convertible main load centers, Series S01 and S02 Retaining Kit Secures ONE circuit breaker right side of interior when used as a back-fed main. HOM4RK2HA 14.70 DE3C For 150–225 A convertible main load centers, Series S01 and S02 Secures circuit breaker to interior when used as a back-fed main. HOM5RK 14.70 DE3C For 2P 150–200 A circuit breakers Miscellaneous Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 93.00 DE3A Replacement Cover 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5 Directory Label Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 DE5 Stickers: For use on “S” Series NEMA 1 and “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main HOMCRBGK1 105.00 DE3D circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker. Generator Circuit For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker HOMCGK2 105.00 DE3D of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. Breaker Interlock Kit For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center HOMRBGK2 105.00 DE3D (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. © 2009 Schneider Electric Discount 1-13 DE2E DE3A DE3B DE3C DE3D DE3E DE5 PE1A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® Homeline Circuit Breakers Plug-On Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us The Square D Homeline circuit breakers are in a 1 in. wide Table 1.39: HOMT Tandem Circuit Breakers format for 1-pole circuit breakers. They are designed to plug into Homeline load centers that are available from 4 1P Tandem—120/240 Vac (One Space Required) to 42 circuits. Ampere Ratingd AIR Cat. No. $ Price 15 and 15 A 10 kA HOMT1515b 52.00 Table 1.34: HOM HOM 1P 15 and 20 A 10 kA HOMT1520b 52.00 1 Space Required 1P—120/240 Vac 2P—120/240 Vac Common Trip Ampere 20 and 20 A 10 kA HOMT2020b 52.00 AIR Rating Cat. No. $ Price Cat. No. $ Price 30 and 15 A 10 kA HOMT3015b 52.00 30 and 20 A 10 kA HOMT3020b 52.00 15 A 10 kA HOM115ab 26.30 HOM215b 60.00 a UL Listed as SWD (switching duty) rated. Suitable for switching 120 20 A 10 kA HOM120ab 26.30 HOM220b 60.00 Vac fluorescent lighting loads. 25 A 10 kA HOM125b 26.30 HOM225b 60.00 b UL Listed as HACR type for use with air conditioning, heating and 30 A 10 kA HOM130b 26.30 HOM230b 60.00 refrigeration equipment having motor group combinations and marked 35 A 10 kA — — HOM235b 60.00 for use with HACR type circuit breakers. 40 A 10 kA HOM140b 26.30 HOM240b 60.00 HOM 2P Table 1.40: HOMT Quad Tandem Circuit Breakers 45 A 10 kA — — HOM245b 60.00 2 Spaces Required 50 A 10 kA HOM150b 26.30 HOM250b 60.00 2P Tandem—120/240 Vac (Two Spaces Ampere Ratingd 60 A 10 kA — — HOM260b 60.00 Required) AIR 70 A 10 kA — — HOM270b 123.00 1P 2P Cat. No. $ Price 80 A 10 kA — — HOM280b 168.00 (2) 15 A 15 A 10 kA HOMT1515215b 120.00 90 A 10 kA — — HOM290b 168.00 (2) 15 A 20 A 10 kA HOMT1515220b 120.00 100 A 10 kA — — HOM2100b 168.00 (2) 15 A 25 A 10 kA HOMT1515225b 120.00 110 A 10 kA — — HOM2110b 369.00 (2) 15 A 30 A 10 kA HOMT1515230b 120.00 125 A 10 kA — — HOM2125b 369.00 (2) 15 A 40 A 10 kA HOMT1515240b 120.00 150 A 10 kA — — HOM2150BBbc 428.00 (2) 15 A 50 A 10 kA HOMT1515250b 120.00 175 A 10 kA — — HOM2175BBbc 428.00 (2) 20 A 20 A 10 kA HOMT2020220b 120.00 200 A 10 kA — — HOM2200BBbc 428.00 (2) 20 A 25 A 10 kA HOMT2020225b 120.00 (2) 20 A 30 A 10 kA HOMT2020230b 120.00 (2) 20 A 40 A 10 kA HOMT2020240b 120.00 Table 1.35: HOM-HM (2) 20 A 50 A 10 kA HOMT2020250b 120.00 High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer HOM2200BB poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common Branch Circuit Breaker 1P—120/240 Vac 2Ps trip (one 30 A 2P CB). Amperes 4 Spaces Required Cat. No. $ Price — 15 A HOM115HMb 27.60 — Table 1.41: Circuit Breaker Wire Sizese 20 A HOM120HMb 27.60 — Wire Size (AWG/kcmil) Ampere Breaker Type Rating Aluminum Copper Table 1.36: HOM-AFI 14–8 AWG or 15–30 A 14–8 AWG HOM Homeline Combination Arc Fault Circuit Interrupters—Provide overload (2) 14–10 AWG 1P and short circuit protection, plus arc fault protection in accordance with 40–50 A 8–2 AWG 8–2 AWG the NEC and UL 1699. HOMT Quad 14–8 AWG or 15–30 A 14–8 AWG Circuit Breaker (2) 14–10 AWG Ampere Poles 120 Circuit Breaker Type Cat. No. $ Price HOM 2 Spaces Required Rating Vac 35–70 A 8–2 AWG 8–2 AWG 2P 15 A 1 HOM115CAFIb 267.00 80–125 A 4–2/0 AWG 4–2/0 AWG Combination Arc-fault Circuit interrupter 20 A 1 HOM120CAFIb 267.00 150–200 A 4 AWG–300 kcmil 4 AWG–300 kcmil HOMT and Quad 15–30 A 14–8 AWG 14–8 AWG Quad Only 40–50 A 6–12 AWG 6–14 AWG Table 1.37: HOM-GFI HOM-GFI - 1P 15–20 A 14–10 AWG 14–10 AWG HOM-GFI circuit breakers provide overload and short circuit protection, HOM-GFI - 2P 15–50 A 12–4 AWG 14–6 AWG combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to Table 1.42: Accessories ground is 6 milliamperes or more. Description Cat. No. $ Price HOM 1P AFI 2P—120/240 Vac 1P—120 Vac Handle Attachments (Arc Fault Circuit Common Trip Ampere AIR Handle Tie: Converts any two adjacent 120/240 Vac Interrupter) Rating 1 Space Required 2 Spaces Required HOM1HTg 3.50 single HOM circuit breakers to independent trip 2P 1 Space Required Cat. No. $ Price Cat. No. $ Price Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side HOMT circuit breakers to independent HOMTHTg 3.80 15 A 10 kA HOM115GFI 212.00 HOM215GFI 413.00 trip 2P 20 A 10 kA HOM120GFI 212.00 HOM220GFI 413.00 Handle Clamp: Clamp for holding HOM 1P handle in QO1LOh 3.80 30 A 10 kA — — HOM230GFI 413.00 the ON or OFF position 40 A 10 kA — — HOM240GFI 413.00 Handle Blocking Device: Attaches to standard HOM 2P 50 A 10 kA — — HOM250GFI 413.00 circuit breakers for holding the handle in the OFF HOM2HBDg 10.70 position Table 1.38: HOM-EPD—10 k AIR Handle Padlock Attachment: For padlocking 1P HOM1PAg 9.90 Standard HOM breakers in the ON or OFF position. Homeline Equipment Protection Device—Circuit Breakers with 30 mA 15–70 A HOM2PALAg 9.90 Handle Padlock Attachment: For Equipment Ground Fault Protection (UL Listed) padlocking 2P Standard HOM circuit 80–125 A HOM2PAHAg 9.90 HOM 1P GFI 2P—120/240 Vac breakers in ON or OFF position 1P—120 Vac 150–200 A HOM2PAVHAg 50.00 (With Ground Fault Common Trip Amperes Handle Padlock Attachment: For padlocking center Circuit Interrupter) HOMQPA 9.90 Cat. No. $ Price Cat. No. $ Price poles of Homeline Quad breakers in the OFF position. 1 Space Required 15 A HOM115EPD 374.00 HOM215EPD 660.00 Handle Padlock Attachment: For 50–125 A QOM1PAfh 11.00 padlocking main circuit breakers in 20 A HOM120EPD 374.00 HOM220EPD 660.00 100–225 A QOM2PAfh 11.00 convertible load center in OFF position 25 A — — HOM225EPD 660.00 Sub-Feed Lugs 30 A — — HOM230EPD 660.00 125 A 2P plug-on—2 spaces required HOML2125 47.60 40 A — — HOM240EPD 660.00 225 A 2P plug-on—4 spaces required HOML2225c 296.00 50 A — — HOM250EPD 660.00 c Requires four spaces (1 AWG–300 kcmil Al/Cu). Use only in 1Ø panel rated 150 A or greater. d 15–20 A tandem or quad tandem circuit breakers are suitable for use o o with 60 C or 75 C conductors. 25–50 A tandem or quad tandem circuit o HOM 2P GFI breakers are suitable for use with 75 C conductors only. o o e 15–30 A circuit breakers are suitable for use with 60 C or 75 C (With Ground Fault o conductors. 40–125 A circuit breakers are suitable for use with 75 C Circuit Interrupter) conductors. 2 Spaces Required f 50–125 A QOM1 frame size; 100–225 A QOM2 frame size. g DE3C Discount Schedule h DE2E Discount Schedule © 2009 Schneider Electric 1-14 Discount DE3D DE3C DE2E Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® Homeline Load Centers Indoor, 1Ø, Main Lug, Main Circuit Breaker Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.43: 1Ø3W—120/240 Vac—UL Listed—10 kA Short Circuit Current Rating Load Center Main Wire Size Equipment Ground Bar Kit Max. Max. Box, Interior and Cover b AWG/kcmil (Order Separately) Box No. Mains Single Tandem Spaces See Rating Pole Circuit $ Price $ Price Page 1-17 Circuits a Breakers Cat. No. Al Cu Cat. No. (DE3C) (DE3A) Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 1-14 Factory-installed Fixed Main Lugs 70 A 2 4 2 HOM24L70F/Sdc 59.00 12–3 14–4 PK3GTA1 11.40 2 100 A 6 12 6 HOM612L100F/Sce 78.00 8–1 PK7GTA 11.70 4 125 A 4 8 4 HOM48L125GC 86.00 12–2/0 14–2/0 PK7GTA Factory-included 21 Convertible Mains—Factory-installed Main Lugs QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16) 816 8 HOM816L125C 132.00 PK15GTA 17.10 6 816 8 HOM816L125TC 150.00 Factory-installed — 6 12 12 0 HOM12L125C 174.00 PK15GTA 17.10 6 12 24 12 HOM1224L125TC 204.00 Factory-installed — 6 125 A 6–2/0 16 24 8 HOM1624L125C 260.00 PK15GTA 17.10 8 20 20 0 HOM20L125C 237.00 PK15GTA 17.10 8 20 24 4 HOM2024L125TC 288.00 Factory-installed — 8 24 24 0 HOM24L125TC 344.00 Factory-installed — 8 Convertible Mains—Factory-installed Main Lugs QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16) 30 30 0 HOM30L150C 375.00 4–250 PK23GTA 21.30 10 150 A 30 30 0 HOM30L150TC 396.00 4–250 Factory-installed — 10 16 32 16 HOM1632L200TC 357.00 9 200 A 16 32 16 HOM1632L200TCFTf 575.00 4–250 Factory-installed — 10 20 40 20 HOM2040L200TC 417.00 9 30 30 0 HOM30L200C 420.00 PK23GTA 21.30 10 30 30 0 HOM30L200TC 464.00 Factory-installed — 10 30 40 10 HOM3040L200TC 479.00 Factory-installed — 10 200 A 40 40 0 HOM40L200C 618.00 4–250 PK23GTA 21.30 12 40 40 0 HOM40L200TC 671.00 Factory-installed — 12 40 60 20 HOM4060L200TC 839.00 Factory-installed — 12 New! 42 52 10 HOM4252L200TC 804.00 Factory-installed — 12 225 A 42 42 0 HOM42L225C 732.00 6–250 PK23GTA 21.30 12 I Main Circuit Breaker—22 kA Short Circuit Current Rating N Convertible Mains—Factory-installed Main Circuit Breaker D QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16) O 816 8 HOM816M100C 315.00 6–1 PK15GTA 17.10 5 O R 816 8 HOM816M100TC 333.00 6–1 Factory-installed — 5 12 12 0 HOM12M100C 294.00 6–2/0 PK15GTA 17.10 6 100 A 12 24 12 HOM1224M100TC 384.00 6–2/0 Factory-installed — 6 20 20 0 HOM20M100C 396.00 6–1 PK15GTA 17.10 7 24 24 0 HOM24M100C 513.00 6–2/0 PK15GTA 17.10 8 30 30 0 HOM30M100C 672.00 6–2/0 PK23GTA 21.30 10 12 24 12 HOM1224M125C 606.00 PK15GTA 17.10 6 12 24 12 HOM1224M125TC 620.00 Factory-installed — 6 125 A 6–2/0 24 24 0 HOM24M125C 710.00 PK15GTA 17.10 8 30 30 0 HOM30M125C 812.00 PK23GTA 21.30 10 Convertible Mains—Factory-installed Main Circuit Breaker QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16) 16 32 16 HOM1632M150TC 636.00 Factory-installed — 9 150 A 20 30 10 HOM2030M150TC 750.00 4–250 Factory-installed — 9 30 30 0 HOM30M150C 776.00 PK23GTA 21.30 10 12 24 12 HOM1224M200TC 572.00 Factory-installed — 9 16 32 16 HOM1632M200TC 675.00 Factory-installed — 9 20 40 20 HOM2040M200C 711.00 PK23GTA 21.30 9 20 40 20 HOM2040M200TC 764.00 Factory-installed — 9 30 30 0 HOM30M200C 798.00 PK23GTA 21.30 10 200 A 4–250 30 40 10 HOM3040M200TC 891.00 Factory-installed — 10 40 40 0 HOM40M200C 1019.00 PK23GTA 21.30 12 40 60 20 HOM4060M200C 1367.00 PK23GTA 21.30 12 42 42 0 HOM42M200C 1094.00 PK23GTA 21.30 12 New! 42 52 10 HOM4252M200C 1313.00 PK23GTA 21.30 12 225 A 42 42 0 HOM42M225C 1116.00 4–250 PK23GTA 21.30 12 Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See page 1-16) 16 32 16 HOM1632U200TC 293.00 Factory-installed — 9 200 A 20 40 20 HOM2040U200TC 357.00 4–250 Factory-installed — 9 30 40 10 HOM3040U200TC 530.00 Factory-installed — 10 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b C at end of catalog number indicates combination flush/surface cover included with device. c F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door. d HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. e 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. f Supplied with feed-thru lugs. © 2009 Schneider Electric Discount 1-15 DE3A DE3C Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® Homeline Load Centers Rainproof, 1Ø, Main Lug, Main Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us Table 1.44: 1Ø3W 120/240 Vac UL Listed Load Centers Load Center Main Wire Size Equipment Ground Bar Kit Max. Single Max. Tandem Box No. Box, Interior and Cover AWG/kcmil (Order Separately) Mains Rating Spaces Pole Circuit See Circuits a Breakers Page 1-17 Cat. No. (DE3C) $ Price Al Cu Cat. No. (DE3A) $ Price Main Lugs (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 10 kA Short Circuit Current Rating Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating 70 A 2 4 2 HOM24L70RBb 111.00 12–3 14–4 PK4GTA 10.80 1R 100 A 6 12 6 HOM612L100RBf 129.00 8–1 PK7GTA 11.70 2R 125 A 4 8 4 HOM48L125GRB 137.00 12–2/0 14–2/0 PK7GTA Factory-included 15R R Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below) A 816 8 HOM816L125RB 248.00 PK15GTA 17.10 3R I 12 12 0 HOM12L125RB 234.00 PK15GTA 17.10 3R N 125 A 6–2/0 P 12 24 12 HOM1224L125RB 278.00 PK15GTA 17.10 3R R 20 20 0 HOM20L125RB 383.00 PK15GTA 17.10 4R O O Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below) F 12 12 0 HOM12L200RB 423.00 PK23GTA 21.30 5R 20 40 20 HOM2040L200RB 560.00 PK23GTA 21.30 6R 30 30 0 HOM30L200RB 587.00 PK23GTA 21.30 7R 200 A 30 40 10 HOM3040L200RB 759.00 — —— 4–250 40 40 0 HOM40L200RB 911.00 PK23GTA 21.30 14R 40 60 20 HOM4060L200RB 1139.00 PK23GTA 21.30 14R New! 42 52 10 HOM4252L200RB 1092.00 PK23GTA 21.30 14R Main Circuit Breaker (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 22 kA Short Circuit Current Rating Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)d 816 8 HOM816M100RB 429.00 6–1 PK15GTA 17.10 3R 12 12 0 HOM12M100RB 416.00 PK15GTA 17.10 3R 100 A 20 20 0 HOM20M100RB 531.00 6–2/0 PK15GTA 17.10 4R 24 24 0 HOM24M100RB 606.00 PK15GTA 17.10 6R 816 8 HOM816M125RB 716.00 PK15GTA 17.10 3R 125 A 6–2/0 24 24 0 HOM24M125RB 858.00 PK15GTA 17.10 6R Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) 150 A 30 30 0 HOM30M150RB 978.00 4–250 PK23GTA 21.30 7R R 20 40 20 HOM2040M200RB 872.00 PK23GTA 21.30 6R A I 30 30 0 HOM30M200RB 1004.00 PK23GTA 21.30 7R N 30 40 10 HOM3040M200RB 1152.00 PK23GTA 21.30 7R 200 A P 4–250 40 40 0 HOM40M200RB 1277.00 PK23GTA 21.30 14R R O 40 60 20 HOM4060M200RB 1596.00 PK23GTA 14.20 14R New! O 42 52 10 HOM4252M200RB 1532.00 PK23GTA 14.20 14R F 16 24 8 HOM1624M225RB 1182.00 PK15GTA 17.10 7R 225 A 4–250 42 42 0 HOM42M225RB 1323.00 PK23GTA 21.30 14R Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs c 150 A 8 16 8 HOM816M150FTRB 785.00 4–250 PK15GTAL 35.00 6R 200 Ae 816 8 HOM816M200FTRB 785.00 4–250 PK15GTAL 35.00 6R Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker or Main Lugsc QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See Kits Below) 200 A 8 16 8 HOM816U200FTRB 446.00 4–250 PK15GTAL 35.00 6R Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. c Side hinge door device allow 1-1/4 in. on left side for door to open. d 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. ® e Rated 200 A when using copper wire. Reference NEC Table 310.15(B)(6) when using Al wire. f 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. Field-Installed Kits Table 1.45: Field-Installed Mains, Convertible Load Centers Only Main Lug Kit Field-Installed Main g Use on Convertible Load $ Price Lug Wire Sizej Frame Size Cat. No. Main Type Ampere Rating Center with Mains Rating (DE3A) AWG/kcmil 125 A 100–125 A QOL125 44.10 6–2/0 Al or Cu Main Lug h — 225 A 150–225 A QOL225 104.00 6–300 Al or Cu 50 A 100–125 A QOM50VH 140.00 60 A 100–125 A QOM60VH 140.00 70 A 100–125 A QOM70VH 140.00 80 A 100–125 A QOM80VH 201.00 QOL125 QOM1 12–2/0 Al or Cu 90 A 100–125 A QOM90VH 201.00 100 A 100–125 A QOM100VH 201.00 110 A 125 A QOM110VH 468.00 Main Circuit Breaker i 125 A 125 A QOM125VH 468.00 100 A 150–225 A QOM2100VH 468.00 125 A 150–225 A QOM2125VH 468.00 150 A 150–225 A QOM2150VH 468.00 QOM2k 4–300 Al or Cu 175 A 200–225 A QOM2175VH 468.00 200 A 200–225 A QOM2200VH 468.00 QOL225 225 A 225 A QOM2225VH 468.00 g Do not exceed the load center mains rating. h If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13. i 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. j Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. k Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00. Discount DE3A DE3C © 2009 Schneider Electric 1-16 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® ® QO and Homeline Load Centers Indoor Load Centers–Dimensions, Knockouts Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us Indoor Knockout Information and Enclosure Dimensions A A,B,C,D A,B,C A,B,C A,B,C A A Table 1.46: Enclosure Dimensions A,B,C Dimensions Dimensions A WH D WH D Box Box No. No. in. mm in. mm in. mm in. mm in. mm in. mm A A A,B 1 3.81 97 6.72 171 3.00 76 13 5.88 149 13.12 333 3.38 86 Box 3 Box 1 Box 2 2 4.81 122 9.30 236 3.19 81 14 14.25 362 20.92 531 3.75 95 3 4.81 122 9.30 236 3.19 81 15 20.00 508 50.00 1270 5.75 146 4 8.88 226 12.57 319 3.80 97 16 20.00 508 62.00 1727 5.75 146 5 14.25 362 14.92 379 3.75 95 17 20.00 508 53.00 1346 5.75 146 C,D,E,F,G B,C,D,E A A,B A B,C,D,E 6 14.25 362 17.92 455 3.75 95 18 5.88 149 16.12 409 3.38 86 A,B B,C,D,E C,D,E,F 7 14.25 362 20.92 531 3.75 95 19 7.56 192 23.12 587 4.25 108 B,C,D,E B,C,D,E 8 14.25 362 26.04 661 3.75 95 20 9.62 244 26.12 663 4.75 121 9 14.25 362 29.86 758 3.75 95 21 8.88 226 14.80 376 3.80 97 A,B 10 14.25 362 33.78 858 3.75 95 22 8.55 217 23.92 608 3.95 100 A 11 14.25 362 37.98 965 3.75 95 23 14.25 362 29.86 758 3.75 95 A 12 14.25 362 39.37 1000 3.75 95 B,C,D,E B,C,D,E A,B,C,D B,C,D,E Table 1.47: Knockout Information Box 4 Box 5 Knockouts Symbol AB CD E F G H I Conduit 1/2 3/4 11-1/41-1/222-1/233-1/2 Size C,D,E,F,G B,C,D,E A A,B C,D,E,F B,C,D,E C,D,E,F,G B,C,D,E A A,B D,E,F,G C,D,E,F,G D,E,F,G B,C,D,E A,B C,D,E,F A B,C,D,E C,D,E,F,G D,E,F,G B,C,D,E A A,B D,E,F,G B,C C,D,E,F C,D,E,F,G B,C,D,E B,C,D,E A A,B C,D,E,F B,C A,B B,C,D,E C,D,E,F A,B A,B A A,B A A A A,B,C,D A,B,C,D B,C,D,E A,B,C,D D,E,F,G D,E,F,G A,B,C,D A,B,C,D C,D,E,F C,D,E,F Box 6 Box 7 Box 8 Box 9 Box 10 C,D,E,F,G C,D,E,F,G B,C,D,E A A,B B,C,D,E A A,B C,D,E,F B,C,D,E B,C,D,E C,D,E,F D,E,F,G D,E,F,G D,E,F,G D,E,F,G D,E,F,G,H,I A,B D,E,F,G,H B,C B,C C,D,E,F A,B,C D,E,F,G A A,B A,B B,C,D,E C,D,E,F A,B C,D,E,F A A,B,C,D A,B A A A,B,C,D A,B,C,D A,B,C,D D,E,F,G C,D,E,F B,C,D,E C,D,E,F B,C,D,E Box 14 Box 13 Box 15, 16, 17 Box 11 Box 12 A,B,C D,E,F,G A,B A C,D,E,F B,C,D,E D,E,F,G D,E,F,G B,C C,D,E,F E,F,G,H C,D,E,F D,E,F,G B,C,D,E A A,B A,B,C,D A,B D,E,F,G B,C,D,E B,C,D,E A A A,B B,C,D,E B,C,D,E A,B,C,D C,D,E,F D,E,F,G C,D,E,F B,C,D,E Box 18 Box 19 Box 20 Box 21 Box 22 Box 23 © 2009 Schneider Electric 1-17 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® ® QO and Homeline Load Centers Rainproof—Dimensions, Knockouts, Bolt-on Hubs Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 1 2 2" Hub Maximum 2 2" Hub Maximum Table 1.48: Enclosure Dimensions Dimensions WH D Box No. in. mm in. mm in. mm A,B B,C A,B B,C 1NM 6.52 166 8.79 223 3.90 99 A B,C,D,E A,B 1Ra 4.88 124 9.38 238 4.00 102 A,B,C,D B,C,D,E A Box 1NM Box 1NM 2R 8.88 226 12.65 321 4.27 108 A,B Box 1R B,C,D,E 3R 14.75 375 18.92 481 4.52 115 1 Box 2R 2 2" Hub Maximum 4R 14.75 375 22.06 560 4.52 115 1 2 2" Hub Maximum 5R 14.75 375 26.04 661 4.52 115 6R 14.75 375 29.86 758 4.52 115 7R 14.75 375 33.78 858 4.52 115 C,D,E,F,G 8R 14.75 375 37.98 965 4.52 115 9R 4.56 116 6.50 165 3.88 99 C,D,E,F,G 10R 6.92 176 13.18 335 4.12 105 11R 7.56 192 23.24 590 4.75 121 12R 9.62 244 26.24 666 5.50 140 C,D,E,F C,D,E,F A,B,C 13R 6.92 176 16.18 411 4.12 105 A A,B C,D,E,F,G 14R 14.75 375 39.37 1000 4.52 115 C,D,E,F C,D,E,F Box 3R, 4R A,B,C 15R 8.88 226 14.80 376 4.27 108 A A,B C,D,E,F,G 16R 8.55 217 24.75 629 4.16 106 1 2 2" Hub Maximum Box 5R 17R 8.88 226 12.65 321 4.27 108 a HOME250SPA and QO260NATR top endwall has no hub opening. Table 1.49: Knockout Information Knockouts C,D,E,F,G Symbol ABCD E F G H A,B,C Conduit Size 1/2 in. 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. Box 9R C,D,E,F C,D,E,F 1 A,B,C 2 2" Hub Maximum 1 A 1 2 2" Hub Maximum 2 2" Hub Maximum A,B C,D,E,F,G Box 6R, 7R, 8R 1 2 2" Hub Maximum 1 2 2" Hub Maximum B,C,D,E B,C,D,E A D,E,F,G A,B B,C,D,E Box 11R Box 15R C,D,E,F B,C,D,E 1 C,D,E,F,G 2 2" Hub Maximum 1 A,B,C,D 2 2" Hub Maximum B, C, D, E B, C, D, E B,C,D,E A B, C, D, E Power lnlet Box 10R, 13R 17R A,B C,D,E,F C,D,E,F A,B,C D,E,F,G A C,D,E,F A,B C,D,E,F,G E,F E,F,G,H Box 14R Box 16R Box 12R Bolt-On Hubs Square D equipment with “R’’ or “RB’’ suffix, designated NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. “RB’’ devices will accept 3/4 in. through 2-1/2 in. bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix “R’’ devices require 3 in. through 4 in. field cut opening. Hubs are suitable for use with conduit having ANSI standard taper pipe thread. Table 1.50: Bolt-On Hubs UL Listed for “RB” Devicesb Conduit Size 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. Hub Cat. No. B075 B100 B125 B150 B200 B250 $ Price 33.30 33.30 33.30 33.30 61.35 102.00 b Closing cap (Cat. No. BCAP) is provided factory-installed on each device having “RB’’ suffix. Price if ordered separately; $2.50 Table 1.51: Bolt-On Hubs UL Listed for Mounting in Field-Cut Opening Conduit Size 3 in. 3-1/2 in. 4 in. “RB’’ Hub Designed for mounting in field cut opening. Hub Cat. No. B300 B350 B400 Includes gasket and four mounting bolts and nuts. $ Price 186.00 300.00 368.00 © 2009 Schneider Electric 1-18 Discount DE1A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Combination Service Entrance Devices Meter Mains, Rainproof Class 4119, 4120 www.schneider-electric.us New! Table 1.52: Meter Mains Meets Federal Spec. W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1Ø3W, NEMA 3R enclosure Load Center and Branch Service Disconnect(s) Circuit Breakers (Order Line Hub Service Weight separately Pages 1-2, 1-3, 1-4) Side Service Type Ground Each Main (Type of Feed) (Order Lug (Lbs) Max. Quantity Cat. No. $ Price Lugs Type separately AWG/ and 2P Ampere Ampere AWG/ (Order separately 1P from kcmil Pallet Circuits Rating Rating kcmil from page 1-22 page 1-17) (Al/Cu) Qty. (Max.) (Max.) (Max.) UL and (Al/Cu) except as noted) UL Circuits Tandems EUSERC Surface Mount Only 125 A None OH/UG — 10 kA C125RB 368.00 1 QOM1-VH 125 A — — — — B 4–1/0 8–1/0 15, 54 OH/UG — 22 kA CM200S 1022.00 1 QOM2-VH 200 A — — — — A 4–250 (2) 8–2/0 26, 24 — 1 QOM2-VH 200 A — — — — 200 A None OH/UG 22 kA C2M200S 1083.00 A 4–250 (2) 8–2/0 27, 20 1 QO-VH 50 A — — — — — OH/UG — 10 kA C4L200S 1143.00 2 QO 100 A — — — — A 4–250 (2) 8–2/0 27, 28 Surface Mount Only 125 A None OH/UG OH/UG 10 kA SC8L125S 846.00 4 HOM 125 Ab — — — — A 6–2/0 6–2/0 31, 24 200 A None OH/UG OH/UG 10 kA SC12L200S 1419.00 6 HOM 200 Am — — — — A–L 4–250 12–2/0 40, 10 Semiflush Mount only 125 A None OH/UG OH/UG 10 kA SC8L125F 846.00 4 HOM 110 A — — — — A or B300 6–2/0 6–2/0 37, 20 None OHd/UG OHd/UG 10 kA SC12L200F 1419.00 6 HOM 200 Aj — — — — A–L 4–250 12–2/0 47, 10 200 A None OHd/UG OHd/UG 22 kA SC816F200Fe 1187.00 1 QOM2200VHa 200 A 8 16 8 200 Aj A–L 4–250 12–2/0 51, 10 Surface Mount—Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers OH/UG 22 kA SC816F150Se 1187.00 1 QOM2150VHa 150 A 8 16 8 150 An A–L 4–250 12–2/0 40, 10 150 A None OH/UG — SC816D150Cef 1 HOM2150a 150 A 10 kA 1250.00 8 16 8 100 Al A or A–L 6–300 12–1/0 48, 18 HOM 50 A UG SU816D150Cef 1 OH/UG 22 kA SC816F200Se 1187.00 1 QOM2200VHa 200 A 8 16 8 200 Am A–L 4–250 12–2/0 40, 10 200 A None OH/UG — SC816D200Cef 1250.00 1 HOM2200a 200 A 10 kA 8 16 8 100 Al A or A–L 6–300 12–1/0 48, 18 50 A UG SU816D200C ef 1250.001HOM Surface Mount Only None RC200Si 1022.00 1 QOM2-VH 200 A A 6–350 (2)8–2/0 26, 24 None RC2M200Si 1083.00 A 6–350 (2)8–2/0 27, 20 1 QOM2-VH 200 A 1 QO-VH 50 A 200 A Horn OH/UG — 22 kA RC2M200SHi 1136.00 —— — — A 6–350 (2)8–2/0 27, 20 None QC12L200Cg 1562.00 6 QO-VH 200 Aj A 6–350 12–2/0 40, 21 Horn QC12L200CHgh 1883.00 6 QO-VH 200 Aj A 6–35012–2/040, 21 Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers 100 A Horn OH/UG — 22 kA QC816F100CHegh 1356.00 1 QOM2100VHa 100 A 8 16 8 100 None OH/UG — 22 kA QC816F125Ceg 1304.00 1 QOM2125VHa 125 A 8 16 8 100 125 A Horn OH/UG — 22 kA QC816F125CHegh 1356.00 1 QOM2125VHa 125 A 8 16 8 100 A 6–350 12–2/0 40, 21 None OH/UG — 22 kA QC816F150Ceg 1304.00 1 QOM2150VHa 150 A 8 16 8 150 Ak 150 A Horn OH/UG — 22 kA QC816F150CHegh 1356.00 1 QOM2150VHa 150 A 8 16 8 150 Ak None OH/UG — 22 kA QC816F200Ceg 1356.00 1 QOM2200VHa 200 A 8 16 8 200 Aj 200 A Horn OH/UG — 22 kA QC816F200CHegh 135600 1 QOM2200VHa 200 A 8 16 8 200 Aj Surface Mount Only 125 A None OH/UG — 10 kA RC8L125S 846.00 4 HOM 125 Ab — — — — A 6–2/0 6–2/0 27, 32 200 A None OH/UG — 10 kA RC12L200Cg 1419.00 6 HOM 200 Aj — — — — A 6–350 12–2/0 40, 21 200 A Horn OH/UG — 10 kA RC12L200CHgh 1419.00 6 HOM 200 Aj — — — — A 6–350 12–2/0 40, 21 Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers 100 A Horn OH/UG — 22 kA RC816F100CHegh 1227.00 1 QOM2100VHa 100 A 8 16 8 100 A 125 A Horn OH/UG — 22 kA RC816F125CHegh 1227.00 1 QOM2125VHa 125 A 8 16 8 100 A None OH/UG — 22 kA RC816F150Ceg 1187.00 1 QOM2150VHa 150 A 8 16 8 150 Ak A 6–350 12–2/0 40, 21 150 A Horn OH/UG — 22 kA RC816F150CHegh 1227.00 1 QOM2150VHa 150 A 8 16 8 150 Ak None OH/UG — 22 kA RC816F200Ceg 1227.00 1 QOM2200VHa 200 A 8 16 8 200 Aj 200 A Horn OH/UG — 22 kA RC816F200CHegh 1227.00 1 QOM2200VHa 200 A 8 16 8 200 Aj 1 HOM2200a 200 A 200 A Horn OH/UG — 10 kA RC816D200CHefho 1292.00 8 16 8 100 Al A or B300 6–300 6–1/0 48, 18 1 HOM 50 A a Service disconnect supplied factory-installed. j Use only 15–100 A and 150–200 A circuit breakers. b 125 A Homeline® 2P circuit breaker can be installed in top position only. All other positions k Use only 15–100 A and 150 A circuit breakers. are limited to 100 A max. l A 100 A circuit breaker can be installed in bottom position only, all other positions are limited c UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker to 70 A. installed. m Use only 15–110 A and 150–200 A breakers. d Suitable for OH service with addition of tunnel kit SCTK20. Order separately. n Use only 15–110 A and 150 A breakers. e Supplied with load side feed-thru lugs, for 6 AWG–250 kcmil (Al/Cu) conductors. o Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories, page f Convertible to semiflush with SC200F flange kit (order separately). 1-22). g Device supplied with barrel lock provisions factory-installed. h Supplied with horn bypass and 5th jaw factory-installed. i 5th jaw factory-installed. © 2009 Schneider Electric Discount 1-19 DE3A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ringless Ring Type ® ® Homeline QO Homeline QO Ampere Rating Bypass Type Short Circuit Current Rating Spaces LOAD CENTERS 1 LOAD CENTERS 1 Combination Service Entrance Devices All-In-Ones, Rainproof 100 to 225 A Maximum Class 4120 www.schneider-electric.us Meter Mains and All-In-Ones Service disconnect(s) are supplied factory-installed, except Ring or ringless type meter socket designs available where noted UL Listed, suitable only for use as service equipment Semiflush-reverse design available, supplied with load center Meets EUSERC standards (indoor access) Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. Meets Federal Specification W-P-115c as Type 1, Class 2 New! Table 1.53: All-In-One Combination Service Entrance Devices Load Center and Branch Circuit Breakers (Order Separately Line Pages 1-2, 1-3, 1-14) Service Weight Service Disconnect(s) Service Side Ground Each (Type Main Max. Quantity Cat. No. List Lug (Lbs) of Feed) Lugs (DE3A) $ Price AWG/ and 1P UL and AWG/ kcmil Pallet EUSERC kcmil Type (Al/Cu) Qty. 2P Ampere (Al/Cu) (Order separately Circuits Rating Tandems from page 1-22 (Max.) (Max.) except as noted) Surface Mount Only 100 A None OH/UG 10 kA SC1624M100S 744.00 1 HOM2100 100 A 16 24 8 100 A A 6–2/0 6–2/0 32, 24 125 A None OH/UG 10 kA SC1624M125S 1518.00 1 HOM2125 125 A 16 24 8 125 Aa 200 A None OH/UG 22 kA SC2040M200S 1671.00 1 QOM2200VH 200 A 20 40 20 200 Ak A-L 4–250 6–2/0 45, 10 200 A None OH/UGf 10 kA SC2040M200Cb 1799.00 1 HOM2200 200 A 20 40 20 100 A A or A-L 6–300 12–1/0 47, 18 200 A None UG 10 kA SU2040M200Cb 1799.00 1 HOM2200 200 A 20 40 20 100 A A or A-L 6–300 12–1/0 47, 18 Semiflush Mount Only 100 A None OH/UG 10 kA SC1624M100F 744.00 1 HOM2100 100 A 16 24 8 100 A A or 6–2/0 6–2/0 44, 20 B300 OH/UG 10 kA SC1624M125F 1518.00 1 HOM2125 125 A 16 24 8 110 A 125 A None OHc/UG 22 kA SC2040M125F 1671.00 1 QOM2125VH 125 A 20 40 20 110 A A-L 4–250 12–2/0 51, 10 OHc/UG 22 kA SC2040M200F 1671.00 1 QOM2200VH 200 A 20 40 20 200 Ak 200 A None SC2636M200FPVd 2244.00 1 QOM2200VH 200 A 26 36 10 100 A OHe/UG 22 kA SC3040M200F 2064.00 1 QOM2200VH 200 A 30 40 10 200 A A-L 4–250 12–2/0 56, 10 SC3040M225F 2280.00 1 QOM2225VH 225 A 30 40 10 200 A 225 A None OHe/UG 22 kA SC2636M225FPVd 2520.00 1 QOM2225VH 225 A 26 36 10 100 A Surface Mount Only 100 A None OHf 10 kA SO1020M100S 443.00 1 HOM2100 100 A 10 20 10 80 A A 6–1 14–4 20, 42 200 A None OHf 22 kA SO2040M200S 1161.00 1 QOM2200VH 200 A 20 40 20 200 Aj A 6–350 8–2/0 43, 21 SC3040M200S 2010.00 1 QOM2200VH 200 A 30 40 10 200 A 4–250 12–2/0 50, 10 200 A None OH/UG 22 kA A-L SC40M200S 2432.00 1 QOM2200VH 200 A 40 40 0 200 A 4–250 12–2/0 52, 10 REVERSE All-In-One—Semiflush Mount with Service Disconnect (outdoor access) and Load Center (indoor access) 200 A None UG 10 kA SU3040M200R 2223.00 1 QOM2200VH 200 A A or 30 40 10 200 A 6–300 12–1/0 60, 15 B300 225 A None UG 10 kA SU3040M225R 2646.00 1 QOM2225VH 225 A Surface Mount Only 100 A RC1624M100S 744.00 1 HOM2100 100 A 100 A None OH/UGf 10 kA 16 24 8 A 6–2/0 6–2/0 32, 24 125 A RC1624M125S 1518.00 1 HOM2125 125 A 125 Aa 125 A Horn OH/UGf 22 kA RC2040M125CHgh 1601.00 1 QOM2125VH 125 A 20 40 20 100 A 150 A Horn OH/UGf 22 kA RC2040M150CHgh 1713.00 1 QOM2150VH 150 A 20 40 20 150 Ai A 6–350 12–2/0 40, 21 None OH/UGf 22 kA RC2040M200Cg 1713.00 1 QOM2200VH 200 A 20 40 20 200 Aj 200 A Horn OH/UGf 22 kA RC2040M200CHgh 1713.00 1 QOM2200VH 200 A 20 40 20 200 Aj Surface Mount Only 150 A Horn OH/UGf 22 kA QC2442M150CHgh 1905.00 1 QOM2150VH 150 A 24 42 18 150 Ai None OH/UGf 22 kA QC2442M200Cg 1905.00 1 QOM2200VH 200 A 24 42 18 200 Aj A 6–350 8–2/0 40, 21 200 A Horn OH/UGf 22 kA QC2442M200CHgh 1905.00 1 QOM2200VH 200 A 24 42 18 200 Aj ® a 125 A Homeline 2P circuit breaker can be installed in top position only. All other g Device supplied with barrel lock provisions factory-installed. positions are limited to 100 A max. h Supplied with horn bypass and 5th jaw factory-installed. b Convertible to semiflush with SC200F flange kit (order separately). i Use only 15–100 A and 150 A circuit breakers. c Suitable for OH service with addition of tunnel kit (SCTK20). Order separately. j Use only 15–100 A and 150–200 A circuit breakers. d For use with Photovoltaic Systems. Provisions for field-installed CT. If required by k Use only 15–110 A and 150–200 A circuit breakers. adopted code, order retaining kit PK2SCPV separately. See page 1-22. e Suitable for OH service with addition of tunnel kit (SCTK30). Order separately. f Device does not meet EUSERC Specifications. © 2009 Schneider Electric 1-20 Discount DE3A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ringless Ring Type ® QO Homeline Homeline Ampere Rating Bypass Type Short Circuit Current Rating Spaces Circuits Ampere Rating (Max.) Hub Type (Order Separately page 1-22) Combination Service Entrance Devices Meter Mains and All-in-Ones, Rainproof 300—400 A Devices Class 4119, 4120 www.schneider-electric.us Meter Mains and All-in-Ones • Ring or ringless type meter socket designs availableService disconnects are supplied factory-installed, except where noted UL Listed, suitable only for use as service equipmentSupplied with 100% branch neutrals; all unused terminals may be used for equipment grounding wiresMeets EUSERC standards Meets Federal Specification W-P-115c as Type 1, Class 2 Table 1.54: Meter Mains Meets Federal Specification W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1Ø3W, NEMA 3R Enclosure Load Center and Branch Circuit Breakers (Order Separately Service Pages 1-2, 1-3, 1-14) Line (Type Service Disconnect(s) a Service Weight Side of Feed) Ground Each Max. Quantity Main List Lug (Lbs) Cat. No. Lugs $ Price AWG/ and 1P AWG/ kcmil Pallet kcmil (Al/Cu) Qty. Type (Al/Cu) 2P Ampere UL and (Order separately UL Circuits Rating Tandems EUSERC from page 1-22 (Max.) (Max.) except as noted) Surface and Semiflush Mount b CU12L400CN c 3810.00 1 QDL22200 d 200 A — — — — 400 A None UG UG 25 kA A–L (2) Studs 4–250 98, 4 1 QDL, QGL, QJLe 200 A — — — — CU12L400FN c 4007.00 4 QOH 125 A h —— — — CU12L400CB ck 3986.00 1 QDL22200 d 200 A — — — — Class 320 400 A Manual UG — 25 kA A–L (2) Studs 4–250 98, 4 1 QDL, QGL, QJLe 200 A — — — — CU12L400FB ck 4182.00 Bypass 4 QOH 125 A h —— — — CU816D400CN ci 3975.00 1 QDL22200 d 200 A 400 A None UG UG 25 kA 8 16 8 200 A A–L (2) Studs 4–250 98, 4 CU816D400FN ci 4172.00 1 QDL, QGL, QJLe 200 A Class 320 CU816D400CB cik 4151.00 1 QDL22200 d 200 A 400 A Manual UG — 25 kA 8 16 8 200 A A–L (2) Studs 4–250 98, 4 CU816D400FB cik 4347.00 1 QDL, QGL, QJLe 200 A Bypass Class 320 400 Af Manual UG — 65 kAa CUM400CB ck 8688.00 1 DGP36400E20LHd 400 A — 2 f — 200 A A–L (2) Studs 4–250 115, 4 Bypass 1 QDL22200 d 200 A — — — — Class 400 A 320 UG — 25 kA QU12L400SL gk 3810.00 1 QDL, QGL, QJLe 200 A — — — — A–L (2) Studs 4–250 98, 4 Lever 4 QOH 125 A h —— — — Surface Mount Only, Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers QU816D400SLigk 1 QDL22200 d 200 A 400 A l UG — 25 kA 4065.00 8 16 8 200 A A–L (2) Studs 4–250 98, 4 QU816D400CK ik 1 QDL, QGL, QJLe 200 A Surface and Semiflush Mount b 1 QDL22200 d 200 A — — — — QU12L400CLgjk 3810.00 400 A UG — 25 kA A–L (2) Studs 4–250 98, 4 1 QDL, QGL, QJLe 200 A — — — — Class 320 QU12L400FLgjk 4007.00 4 QOH 125 A h —— — — Lever QU816D400CLgjik 4065.00 1 QDL22200 d 200 A 400 A UG — 25 kA 8 16 8 200 A A–L (2) Studs 4–250 98, 4 QU816D400FLgjik 4262.00 1 QDL, QGL, QJLe 200 A Class 320 400 Af UG — 65 kAa QUM400CLck 10000.00 1 DGP36400E20LHd 400 A — 2 f — 200 A A–L (2) Studs 4–250 120, 4 Lever K-4 Bolt- 400 Af UG — 65kAa QUM400CKck 11175.00 1 DGP36400E20LHd 400 A — 2 f — 200 A A–L (2) Studs 4–250 123, 4 None Table 1.55: All-in-One Combination Service Entrance Devices Surface and Semiflush Mount b 1 QDL22200 d 200 A 300 A None UG UG 25 kA SU3040D300CN cj 6600.00 30 40 10 200 A A–L (2) Studs 4–250 100, 4 1 QDL, QGL, QJL e 100 A Class 320 SU3040D300CB cjk 6600.00 1 QDL22200 d 200 A 300 A UG — 25 kA 30 40 10 200 A A–L (2) Studs 4–250 100, 4 Manual SU3040D300FB cjk 6797.00 1 QDL, QGL, QJLe 100 A SU3040D400CN cj 7050.00 1 QDL22200 d 200 A 400 A None UG UG 25 kA 30 40 10 200 A A–L (2) Studs 4–250 100, 4 SU3040D400FN cj 7247.00 1 QDL, QGL, QJLe 200 A Class 320 SU3040D400CBcjk 7167.00 1 QDL22200 d 200 A 400 A UG — 25 kA 30 40 10 200 A A–L (2) Studs 4–250 100, 4 Manual SU3040D400FB cjk 7364.00 1 QDL, QGL, QJLe 200 A Class 320 RU3040D400CL gjk 6993.00 1 QDL22200 d 200 A 400 A UG — 25 kA 30 40 10 200 A A–L (2) Studs 4–250 100, 4 Lever RU3040D400FL gjk 7190.00 1 QDL, QGL, QJLe 200 A K-4 Bolt- RU3040D400CK jk 6993.00 1 QDL22200 d 200 A 400 A UG — 25 kA 30 40 10 200 A A–L (2) Studs 4–250 100, 4 on RU3040D400FK jk 7190.00 1 QDL, QGL, QJLe 200 A a UL short circuit current rating is equal to the lowest interrupting rating of any circuit f Option for field installation of two Q-frame, 200 A max. 2-pole branch circuit breakers used as breaker installed. mains for two downstream load centers. Purchase installation kit BMK2Q400 and two Q-frame circuit breakers separately. Order QBL prefix at 10 kA, QDL prefix at 25 kA, or QGL b For 400 A device with suffix CB, CK, CL, or CN, surface-mount convertible to semiflush prefix at 65 kA. with FK400 flange kit (order kit separately). Devices wtih suffix FB, FL, FN or FK are semiflush only, with the top endwall factory-installed and flanges factory-included. g Fifth jaw factory-installed. c For use only on 120/240 Vac 1Ø3W system (4-jaw meter socket). h QO panel is rated 200 A maximum. d Service disconnect supplied factory-installed. i Supplied with load side feed-thru lugs for 6 AWG–250 kcmil (Al/Cu) conductors. e Additional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25 j Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories, page 1- kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker 22). catalog number, see Section 7. k Device configuration is not included in EUSERC standards. Consult applicable utility for acceptance. l Device with suffix L has Class 320 lever bypass and device with suffix K has a K-4 bolt-on, no bypass. © 2009 Schneider Electric 1-21 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ringless Ring Type Ringless Type Ring Type ® ® Homeline QO Ampere Rating Bypass Type Short Circuit Current Rating Spaces Circuits Ampere Rating (Max.) Hub Type (Order Separately page 1-22) LOAD CENTERS 1 LOAD CENTERS 1 Combination Service Entrance Devices Circuit Breakers, Accessories, Hubs Class 4119, 4120 www.schneider-electric.us Table 1.56: Circuit Breakers for use with Meter Mains and All-In-One Devices Type: HOM, 1P Type: HOM, 2P Type: QO, 1P Type: QO, 2P Type: QO-VH, 1P Type: QO-VH, 2P Ampere Rating Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. $ Price $ Price $ Price $ Price $ Price $ Price a (DE3D) (DE3D) (DE2A) (DE2A) (DE2A) (DE2A) 10 — — — — QO110 29.10 —— — — — — 15 HOM115 26.30 —— QO115 29.10 —— QO115VH 63.00 —— 20 HOM120 26.30 —— QO120 29.10 —— QO120VH 63.00 —— 25 HOM125 26.30 —— QO125 29.10 —— QO125VH 73.00 —— 30 HOM130 26.30 HOM230 60.00 QO130 29.10 QO230 67.00 QO130VH 73.00 QO230VH 146.00 35 — — HOM235 60.00 QO135 29.10 QO235 67.00 —— — — 40 HOM140 26.30 HOM240 60.00 QO140 29.10 QO240 67.00 —— QO240VH 146.00 45 — — HOM245 60.00 QO145 29.10 QO245 67.00 —— — — 50 HOM150 26.30 HOM250 60.00 QO150 29.10 QO250 67.00 —— QO250VH 146.00 60 — — HOM260 60.00 QO160 29.10 QO260 67.00 —— QO260VH 146.00 70 — — HOM270 123.00 QO170 67.00 QO270 134.00 —— QO270VH 224.00 80 — — HOM280 168.00 —— QO280 189.00 —— QO280VH 315.00 90 — — HOM290 168.00 —— QO290 189.00 —— QO290VH 315.00 100 — — HOM2100 168.00 —— QO2100 189.00 —— QO2100VH 315.00 110 — — HOM2110 369.00 —— QO2110 428.00 —— QO2110VH 1034.00 125 — — HOM2125 369.00 —— QO2125 428.00 —— QO2125VH 1034.00 150 — — HOM2150BB 428.00 —— QO2150 491.00 —— QO2150VH 1061.00 175 — — HOM2175BB 428.00 —— QO2175 491.00 —— QO2175VH 1061.00 200 — — HOM2200BB 428.00 —— QO2200 491.00 —— QO2200VH 1061.00 Ampere Type: QOM1-VH, 2P Type: QOM2-VH, 2P Type: QDL, 2Pc Rating Cat. No. (DE3D) $ Price Cat. No. (DE3D) $ Price Cat. No. (DE2A) $ Price a 50 QOM50VHb 140.00 —— — — 60 QOM60VH 140.00 —— — — 70 QOM70VH 140.00 —— QDL22070 1143.00 80 QOM80VH 201.00 —— QDL22080 1143.00 90 QOM90VH 201.00 —— QDL22090 1143.00 100 QOM100VH 201.00 QOM2100VH 468.00 QDL22100 1143.00 110 QOM110VH 468.00 —— QDL22110 1143.00 125 QOM125VH 468.00 QOM2125VH 468.00 QDL22125 1143.00 150 — — QOM2150VH 468.00 QDL22150 1143.00 175 — — QOM2175VH 468.00 QDL22175 1143.00 200 — — QOM2200VH 468.00 QDL22200 1143.00 225 — — QOM2225VH 468.00 —— a Do not exceed mains rating of device b Reference National Electrical Code Article 230-79. c For additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA. Table 1.57: Accessories, Hubs and Closing Plates Accessories Hubs and Closing Plates Disc. Hub Conduit Size Disc. Description Cat. No. $ Price Cat. No. $ Price Sch. Series (inches) Sch. Closing Plate for “A” Hub opening ACP 13.40 DE4 Generator Kit: Interlocks main service disconnect and generator circuit breaker (order separately). For : 1.00 A100 33.90 DE4 ®Homeline CSED Devices RC816F-, RC2040M-, SO2040M- RCGK2 245.00 DE4 1.25 A125 33.90 DE4 QO CSED Devices QC816F-, QC2442M- QCGK3 245.00 DE4 1.50 A150 33.90 DE4 A Backfed inverter circuit breaker retaining kit for SC2636M200FPV and SC2636M225FPV PK2SCPV 47.40 DE4 2.00 A200 47.90 DE4 Meter Main Types: C, RC, SC, QC Fifth Jaw Kit for: 5J 18.30 DE4 All-In-One Types: SC, SU (100–225 A), QC, RC, SO 2.50 A250 61.00 DE4 Bypass (Horn Type) for Ringless Type Meter Mains and All-In-Ones (100–200 A) MMHB 16.70 DE4 Adapter plate to allow use of “A” (except for RC8L125S, RC1624M100S and RC1624M125S–use RCHB). AAP 33.80 DE4 Hubs on “A-L” size hub openings Lexan Meter Socket Cover Plate for: Closing Plate for “A-L” Hub 29007 10.10 DE4 ACPL 18.30 DE4Ring and Ringless Type Meter Mains opening Ring and Ringless Type All-In-Ones 2.00 A200Ld 83.00 DE4 Meter Socket Sealing Rings for Ring Type Meter Mains and All-In Ones: 2.50 A250L 87.00 DE4 Snap Type Aluminum (Std.) 2920910001 7.95 DE5 A-L 3.00 A300L 111.00 DE4 Screw Type Aluminum 29008W 20.10 DE4 3.50 A350L 114.00 DE4 Snap Type Stainless Steel ARP00026 16.70 DE4 4.00 A400L 119.00 DE4 Anti-Inversion Kit . For use ONLY on 400 A Meter Mains and All-In-Ones with lever bypass. MMLRK 12.00 DE4 Closing Plate for “B” Hub opening BCAP 3.80 DE1A 0.75 B075 33.30 DE1A Trim Kit for 2 in. X 6 in. stud wall, used with Reverse All-In-Ones, SU3040M200R, and SU2X6TRIM 266.00 DE4 SU3040M225R 1.00 B100 33.30 DE1A 1.25 B125 33.30 DE1A Barrel Lock Kit (Barrel Lock not included), supplied with bracket and mounting screw, refer to SCBRLLOCK 53.00 DE4 B listings for where used. 1.50 B150 33.30 DE1A 2.00 B200 61.35 DE1A Meter Mains: SC816D150/200C and RC816D200CH Semiflush Flange Kit for: SC200F 31.80 DE4 All-In-Ones: SC2040M200C 2.50 B250 102.00 DE1A Semiflush Flange Kit for ring- and ringless-type Meter Mains and All-In-Ones (400 A Only) FK400 197.00 DE4 B300 3.00 B300 186.00 DE1A Ringless Type Utility Cover for RU3040D400CL/FL, QU12L400CL/FL, and QU816D400CL/FL. d Supplied with AAP adapter plate and “A” hub. R400L 266.00 DE4 Includes one piece meter socket and pull box cover with handles and closing plate. Lug Kit includes (4) lugs, for use with 2 AWG–600 kcmil Al/Cu conductors. Lugs are for standard 2-Hole mounting. Meter Main and All-In-One units supplied with (2) studs per phase and neutral CMELK4 137.00 DE4 will accept one lug per phase and neutral. Not for use on 400 A devices with “K” suffix. Branch Circuit Breaker Field Installation Kit for two Q-Frame Circuit Breakers (QBL, QDL, or QGL, order separately). For CUM400CB, QUM400CL or QUM400CK - includes (2) mounting BMK2Q400 153.00 DE4 pans, (4) wires. Overhead Feed Trough for 400 A ring- and ringless-type Meter Mains and All-In-Ones. OCK400 567.00 DE4 Touch-Up Paint (ASA49 Gray) PK49SP 39.00 DE1 Ground Bar Kit, Meter Mains and All-In-Ones QC, RC, and SC (100–225 A) PK15GTA 17.10 DE3A Filler Plate for: Meter Main Types: QC, CU All-In-One Types: QC QOFP 3.60 DE3A Filler Plate for: Meter Main Types: RC, SC All-In-One Types: SC, RC, SU HOMFP 3.20 DE3A Neutral Lug (6-2/0 AWG) Meter Main Types: RC, SC, QC All-In-One Types: SC, SU, QC, RC LK100AN 10.80 DE3A for: © 2009 Schneider Electric 1-22 Discount DE1 DE1A DE2A DE3A DE3D DE4 DE5 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Combination Service Entrance Devices Dimensions Class 4119, 4120 www.schneider-electric.us a Driphood supplied factory-installed and is required Table 1.58: Knockouts 14.97 “A” Hub for surface mount installation. 380 For semi-flush installation, remove driphood and Symbol ABCD E F G H I J 28.28 install flange kit SC200F (order separately). 718 7.14 B,C,D b Unit supplied with blank top endwall (factory- C,D,F 181 Conduit A 1/2 3/4 11-1/41-1/222-1/233-1/24 installed) for surface mount installation. For semi- Size (in.) flush installation, install flange kit FK400 (order 7.50 Drip Hood 191 separately). Kit includes replacement top endwall (with knockouts) and flanges. c Unit supplied with semi-flush top endwall factory Semi-Flush End Wall installed and semi-flush flanges factory included. 1 “A” Hub 2 /2" Max “A” Hub “B” Hub 4.60 4.60 4.56 7.50 117 117 Blank End Wall 116 191 13.82 19.58 13.46 351 497 28.25 342 718 7.44 6.44 8.00 189 164 10.70 203 272 12.80 325 18.23 463 20.79 528 A,B C,D,E,F 41.25 A,B E,F,G,H 1048 C,D,E,F A C125RB (Shown) B,C CQRB100 D,F,G A,B Ring Type: Ringless Type: SO1020M100S CM200S RC200S C2M200S (Shown) RC2M200S 1 2 /2" Max “A” Hub A C4L200S RC2M200SH G,H,I,J 1 “A-L” Hub 2 /2" Max “A” Hub 4.67 C,D,F A,B 119 B,C A C,D,F B,C 4.80 14.37 122 3.39 CU12L400CNc CU816D400CBc 365 Surface 86 CU12L400CBc CU816D400CNc QU12L400CLc QU816D400CLc 14.77 375 QU12L400SL QU816D400SL (Shown) 14.50 10.04 368 255 CU12L400FNf 1 2 /2" Max “A” Hub CU12L400FBf D,F,G 10.87 CU816D400FNf B,C 276 CU816D400FBf C,D,F 10.87 QU816D400CKc 276 QU12L400FLf 6.95 35.13 176 892 QU816D400FLf 25.12 638 25.12 638 14.50 368 A 14.81 1 2 /2" Max 376 A,B B,C A “A” Hub A,B D,F,G B,C D,F,G 1 2 /2" Max A,B “A” Hub or D,E,F,G C,D,F B300 A,B,C 32.23 SC8L125S (Shown) C,D,E,F 819 RC8L125S SC8L125F (Shown) C,D,E,F SC1624M100S SC1624M100F RC816F100CH QC816F100CH SC1624M125S SC1624M125F RC816F125CH QC816F125C/CH RC1624M100S RC816F150C/CH QC816F150C/CH (Shown) RC1624M125S C,D,E,F RC816F200C/CH QC816F200C/CH A,B RC12L200C/CH QC12L200C/CH A B,C A RC2040M125CH QC2442M150CH A C,D,F A,B C,E,F,G,H A,B 3.40 RC2040M150CH QC2442M200C/CH 1 2 /2" Max 86 RC2040M200C/CH SO2040M200S “A-L” Hub B,C C,D,E,F 14.62 7.90 B,C 14.85 371 201 377 SU816D150Cq SU816D200Cq 7.50 Blank End Wall 191 SU2040M200Cq C L RC816D200CHq Top Branch SC816D150Cq 28.25 Circuit 718 SC816D200Cq(Shown) Breaker 31.61 8.00 1 27.00 2 /2" Max “A” Hub 803 39.60 203 686 35.40 1006 899 5.80 147 48.00 1219 21.50 546 C L 10.30 41.25 262 1048 Meter 11.10 Socket 282 B,C B 29.50 749 C,E,F,G,H 32.30 21/2" Max A 820 “A-L” Hub 4.40 B,C B A 112 37.30 “A” Hub or B C,D,E,F 3.50 947 B300 Hub A 89 SC816F200F SC12L200F G,H,I,J D,F,G 35.40 B C,D 899 “A-L” Hub SC2040M125F SU3040M200R (Shown) SC2040M200F (Shown) C,D,E,F A SU3040M225R C,D,F B,C C,E,F,G,H SC3040M200F 1 2 /2" Max B,C SU3040D400CBc (Shown) SC3040M2225F SU3040D300CBc 39.60 “A-L” Hub RU3040D400CLc SU3040D400CNc 1006 SC2636M200FPV RU3040D400CKc RU3040D400FLf SC2636M225FPV B SU3040D300FBf RU3040D400FKf SC12L200S SC40M200S SU3040D400FBf c CUM400CB SC816F150S SC2040M200S (Shown) SU3040D400FNf c QUM400CL SC816F200S SC3040M200S QUM400CKc © 2009 Schneider Electric 1-23 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SC40M200S SC3040M200S LOAD CENTERS 1 LOAD CENTERS 1 Enclosed Devices Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Enclosed GFCI Circuit Breakers—UL Listed Enclosed Molded Case Switches—UL Listed Table 1.61: 2P, 120/240 Vac, GFCI circuit breaker included, 10 k Table 1.59: Molded Case Switch Included. Does not provide AIR overcurrent protection Type 3R—Rainproof Box. No. General Purpose Rainproof Box. No. Ampere Circuit Breaker Ampere Service See Page Service See Page Rating Included Rating Cat. No. $ Price 1-17 Cat. No. $ Price Cat. No. $ Price 1-17 QO200TR 161.00 2, 9Rc 1NM (Non- QOE250GFINM 528.00 QO250GFI 240 Vac 60 Aab QO260NATS 161.00 QO200TRNM 191.00 1NM 120/240 Vac 50 A metallic) HOME250SPA 473.00 HOM250GFI 1R (Metallic) QO260NATR 168.00 1R Circuit Breaker Enclosures—UL Listed 120/240 Vac 100 Ad QO2000NS 276.00 QO2000NRB 338.00 13, 10R Table 1.62: 22 kA Short Circuit Current Rating. ® Not for use with one pole QO circuit breakers. Circuit breakers not included. Order QO , Table 1.60: Housing Bracket QO-GFI, QO-AFI, QO-EPD and QO-PL circuit breakers separately from pages 1-2 and 1-3. Accepts QO circuit breakers with factory-installed accessories. Order equipment ground Description Cat. No. $ Price bar PKOGTA2, if required. Bracket used with QO200TR for stucco, aluminum and vinyl siding. PKHB 6.30 Order quantity multiples of 10. General Purposee Rainproof Box. No. Ampere Service See Page Rating Cat. No. $ Price Cat. No. $ Price 1-17 120/240 100 A QO2100BNF/S 83.00 QO2100BNRB 135.00 13, 10R Vac 125 A QO2125BNF/S 108.00 QO2125BNRB 158.00 18, 13R 240 Vac 100 A QO3100BNF/S 149.00 QO3100BNRB 207.00 13, 10R Table 1.63: 10 kA Short Circuit Current Rating. Circuit breaker not included. Order separately from page 1-2. Will not accept QO-GFI PKHB circuit breaker nor QO circuit breakers with factory-installed accessories. Housing QO200TRNM QO3100BNF Bracket 240 Vac 60 Aa —— QO2TR 95.00 9Rc With Cover Removed Table 1.64: Q Frame Enclosures and Q Frame Circuit Breakers—UL Listed Enclosure Onlyg Circuit Breaker (Order Separately) Type 1—General Purposee Type 3R—Rainproof Box No. 10 k AIR 25 k AIR 65 k AIR 100 k AIR Service Ampere See Page Rating Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price 1-17 70 A QBL22070 474.00 QDL22070 1143.00 QGL22070 1521.00 QJL22070 1890.00 80 A QBL22080 474.00 QDL22080 1143.00 QGL22080 1521.00 QJL22080 1890.00 90 A QBL22090 474.00 QDL22090 1143.00 QGL22090 1521.00 QJL22090 1890.00 100 A QBL22100 474.00 QDL22100 1143.00 QGL22100 1521.00 QJL22100 1890.00 Q22200NSh 176.00 Q22200NRBh 380.00 19, 11R 110 A QBL22110 474.00 QDL22110 1143.00 QGL22110 1521.00 QJL22110 1890.00 2P 240 Vac or or Maximum 125 A QBL22125 474.00 QDL22125 1143.00 QGL22125 1521.00 QJL22125 1890.00 Q23225NF/S 218.00 Q23225NRB 417.00 20, 12R 150 A QBL22150 474.00 QDL22150 1143.00 QGL22150 1521.00 QJL22150 1890.00 175 A QBL22175 474.00 QDL22175 1143.00 QGL22175 1521.00 QJL22175 1890.00 200 A QBL22200 474.00 QDL22200 1143.00 QGL22200 1521.00 QJL22200 1890.00 225 A QBL22225 474.00 QDL22225 1143.00 QGL22225 1521.00 QJL22225 1890.00 70 A QBL32070 1248.00 QDL32070 1784.00 QGL32070 2442.00 QJL32070j 2796.00 80 A QBL32080 1248.00 QDL32080 1784.00 QGL32080 2442.00 QJL32080j 2796.00 90 A QBL32090 1248.00 QDL32090 1784.00 QGL32090 2442.00 QJL32090j 2796.00 100 A QBL32100 1248.00 QDL32100 1784.00 QGL32100 2442.00 QJL32100j 2796.00 110 A QBL32110 1248.00 QDL32110 1784.00 QGL32110 2442.00 QJL32110j 2796.00 3P 240 Vac Q23225NF/S 218.00 Q23225NRB 278.00 20, 12R 125 A QBL32125 1248.00 QDL32125 1784.00 QGL32125 2442.00 QJL32125j 2796.00 150 A QBL32150 1248.00 QDL32150 1784.00 QGL32150 2442.00 QJL32150j 2796.00 175 A QBL32175 1248.00 QDL32175 1784.00 QGL32175 2442.00 QJL32175j 2796.00 200 A QBL32200 1248.00 QDL32200 1784.00 QGL32200 2442.00 QJL32200j 2796.00 225 A QBL32225 1248.00 QDL32225 1784.00 QGL32225 2442.00 QJL32225j 2796.00 Table 1.65: QOM2 Enclosures and QOM2 Circuit Breakers—UL Listed QOM2 Circuit Breaker Enclosure Onlyf (Order Separately)i Type 1 Type 3R Box No. Service 22 k AIR General Purposee Rainproof See Ampere Pages Rating Cat. No. $ Price Cat. No. $ Price Cat. No.k $ Price 1-17 100 A QOM2100VH 468.00 125 A QOM2125VH 468.00 150 A QOM2150VH 468.00 QOM22225NF/S 234.00 QOM22225NRB 440.00 22, 16R 175 A QOM2175VH 468.00 2P 240 Vac Maximum 200 A QOM2200VH 468.00 225 A QOM2225VH 468.00 a Not suitable for service equipment. h Accepts 200 A max. 2P Q Frame circuit breakers. b Maximum 10 hp 240 Vac. i Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126. c Top endwall has no hub opening. j When these 3P circuit breakers are mounted in d Maximum 20 hp 240 Vac. an enclosure, the maximum AIR rating is 65 kA at e Order F for flush, S for surface. 240 Vac and 100 kA at 208 Vac. f Equipment ground bar kit PKOGTA2 k DE3A Discount Schedule. factory-included. Q22200NS QOM22225NS Q23225NF g Factory-installed groundable neutral assembly With Cover Removed With Cover Removed includes (2) ground lugs and (2) neutral lugs. Equipment ground kit PKOGTA2 also included. (Order Q-Frame circuit breaker separately) © 2009 Schneider Electric 1-24 Discount DE2A DE3A Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® Servicepak Power Outlet Panels Class 1140 www.schneider-electric.us For Construction Sites Provide temporary power at construction sites. ® T TEach receptacle protected by QO-GFI circuit breaker in compliance with NEC requirements. T T T Each enclosure is rainproof. 1C 2C 3C10 kA short circuit current rating. UL Listed as suitable for use as temporary site service equipment. Provided with neutral bonding provisions. T T T T T T Boxes have provisions for type “B’’ hubs to be field-installed. Table 1.66: Construction Site Panels 4C 5C 6C Receptacles Main Wire Size Power Mains Service Circuit Breaker (Included) AWGd Outlet Ampere Cat. No.c $ Price a (Included) Configuration Rating ACD E F Cu Al TT T T T T TT T 1C 1Ø2W 40 A (1) QO120GFI 1 PAK10C1 441.00 14–6 12–6 2C 1Ø2W 40 A (2) QO120GFI 2 PAK11Ce 818.00 14–6 12–6 2C 1Ø2W 40 A (2) QO120GFI 2 PAK11C1 818.00 14–6 12–6 (1) QO120GFI 7C 8C 9C 3C 1Ø3W 70 A 11 PAK31CGFI 974.00 8–1 8–1 (1) QO230GFI (1) QO120GFI 4C 1Ø3W 70 A 11 PAK36C1GFI 974.00 8–1 8–1 (1) QO220GFI T T T T (1) QO120GFI 5C 1Ø3W 70 A 11 PAK51CGFI 974.00 8–1 8–1 (1) QO250GFI 10C 11C 12C (1) QO120GFI 6C 1Ø3W 70 A 11 PAK55CGFI 974.00 8–1 8–1 (1) QO250GFI (2) QO120GFI 7C 1Ø3W 70 A 21 PAK72CGFI 1323.00 8–1 8–1 (1) QO220GFI T T (2) QO120GFI 8C 1Ø3W 70 A 21 PAK76CGFI 1323.00 8–1 8–1 (1) QO250GFI (1) QO120GFI 9C 1Ø3W 100 A 12 PAK1004CGFI 1581.00 14–1 12–1 (2) QO250GFI 13C 14C For Recreational Vehicle Parks Provide electrical power to individual recreational vehicle park sites. ® 20 A 125 V 2W and Grd.Each receptacle protected by appropriate GFI or Standard QO circuit breaker. A NEMA 5-20R All receptacles and circuit breakers included. 10 kA short circuit current rating. 30 A 125 V 2W and Grd B ANSI 73.13 UL Listed. All enclosures are rainproof. 50 A 125/250 V 3W and Grd. No neutral bonding provisions. C NEMA 14-50R Loop-feed provisions. 20 A 250 V 2W and Grd. Table 1.67: Recreational Vehicle Park Panels D NEMA 6-20R Main Wire Size Receptacles AWG/kcmilf Mains 30 A 125/250 V 3W and Grd. Power Outlet Service Circuit Breaker (Included)b Ampere Cat. No. $ Price E NEMA 14-30R Configuration a (Included) Phase and Neutral Rating A B C Cu Al 50 A 250 V 2W and Grd. Underground or Overhead Loop-Feed Terminals—Non-Pedestalcg F NEMA 6-50R 10C 1Ø2W 40 A (1) QO120GFI 1 PAK10CTG 470.00 All non-pedestal devices have provisions to field- 11C 1Ø2W 40 A (2) QO120GFI 2 PAK11CTG 795.00 14–6 12–6 install a Type “B’’ hub on the bottom endwall for (1) QO120GFI 12C 1Ø2W 50 A 11 PAK41CTGh 564.00 bottom feed from a conduit riser. Order Type “B’’ (1) QO130 bolt-on hub (B250 Max.) and two mounting screws (1) QO120GFI 13C 1Ø2W 75 A 12 PAK61CTGh 654.00 (Cat. No. 8002505501) and two hex nuts (Cat. No. (2) QO130 2340102000). 14–1 12–1 (1) QO120GFI PAK75CTG 14C 1Ø3W 100 A (1) QO250 111 669.00 (Not Loop Feed)h (1) QO130 Pedestal Mounted—Underground Loop-Feed Terminalsij 11C 1Ø2W 40 A (2) QO120GFI 2 PAK11PG 1035.00 (1) QO120GFI 12C 1Ø2W 50 A 11 PAK41PGh 852.00 (1) QO130 (1) QO120GFI (2)6–250 (2)6–250 13C 1Ø2W 75 A 12 PAK61PGh 914.00 (2) QO130 (1) QO120GFI 14C 1Ø3W 100 A (1) QO250 111 PAK75PGh 1007.00 (1) QO130 a (1Ø2W 120 Vac) (1Ø3W 120/240 Vac) b 20 A receptacles protected by 20 A GFI circuit breaker. c Devices have a bolt-on factory-installed closing cap. Order type "B’’ bolt-on hub separately from page 1-18. d Equipment ground terminal suitable for (2) 14 or 12 AWG Cu or (2) 12 or 10 AWG Al. e Receptacles in this device are in bottom endwall and are accessible with outer door padlocked. "Order Only’’ from Lexington—Minimum order quantity is 50 devices. f Two wires each per phase, neutral, and equipment ground—for loop feed (except PAK75CTG). g Equipment ground terminal suitable for (2) 14–12 AWG Cu or (2) 12–10 Al. h GFI circuit breaker can be substituted for standard 30 A circuit breaker. For 30 ampere receptacles add $140.00 per circuit breaker. Add suffix "FI’’ to catalog number. Example: PAK41CTGFI. i Stabilizer foot available for use in unstable ground, order HNPSF $27.50 list. j Equipment ground terminals suitable for (2) 10–2/0 AWG Cu or (2) 6–2/0 AWG Al. © 2009 Schneider Electric Discount 1-25 DE4 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LOAD CENTERS 1 LOAD CENTERS 1 ® Servicepak Power Outlet Panels Class 1140 www.schneider-electric.us 2.50 Hub Maximum 2.50 64 0.28 Hub Maximum 64 Dia. 7 1.25 0.28 Dia. 7 32 (3 Holes) 8.50 6.25 216 159 9.40 2.26 3.24 7.90 A, B, C 239 82 57 201 2.45 1.00 62 25 D, E, F, G Knockout 5.80 4.63 3.75 0.17 0.18 R or 2.50 Hub Maximum 147 118 95 64 4 5 0.96 2.75 24 70 7.75 4.90 4.00 197 124 102 PAK10C1 PAK11C PAK11C1 2.50 2.50 0.28 2.50 Hub Maximum Hub Maximum Hub Maximum Dia. 64 64 64 7 0.28 Dia. (3 Holes) 7 0.28 Dia. (3 Holes) 7 1.26 (3 Holes) 1.26 32 32 8.50 6.25 216 159 2.26 3.24 A, B, C 57 82 14.21 14.21 16.43 16.43 361 417 361 417 1.00 3.24 25 82 5.80 2.26 D, E, F, G Knockout 4.63 3.75 147 57 or 2.50 Hub Maximum 118 A, B, C 2.26 3.24 95 64 57 82 A, B, C 0.96 2.75 24 5.80 4.63 70 D, E, F, G Knockout 3.75 147 118 7.75 or 2.50 Hub Maximum 95 197 5.80 64 D, E, F, G Knockout 0.96 4.63 3.75 147 or 2.50 Hub Maximum PAK10CTG 118 24 2.75 95 64 PAK11CTG 70 PAK41CTG 0.96 7.75 PAK41CTGFI 2.75 24 197 70 7.75 PAK31CGFI 197 PAK36C1GFI PAK61CTG PAK51CGFI PAK61CTGFI PAK55CGFI PAK75CTG PAK72CGFI PAK75CTGFI PAK76CGFI PAK1004CGFI 5.80 7.60 5.80 7.60 147 193 147 193 8.63 16.43 219 421 34.50 (2) #6 AWG–250 kcmil 876 per phase and neutral 42.31 (2) #6 AWG–250 kcmil (2) #10–2/0 AWG Cu 19.63 1083 59.50 per phase and neutral (2) #6–2/0 AWG Al 499 1511 Equipment Grounding Lugs (2) #10–2/0 AWG Cu 19.63 6.50 67.30 (2) #6–2/0 AWG Al 499 165 1723 6.50 6.25 Equipment Grounding Lugs 159 165 0.75 6.25 25.00 159 19 0.75 2.00 635 18.50 Final Grade 19 3.50 51 25.00 2.00 470 89 18.50 635 51 3.50 Detail A Final Grade 470 89 Detail A Detail A Detail A PAK61PG PAK11PG PAK61PGFI PAK41PG PAK75PG PAK41PGFI PAK75PGFI © 2009 Schneider Electric 1-26 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the SU3040D300CN?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods