SCHNEIDER ELECTRIC LC1D115G7
Specifications
50/60 Hz Voltage Code
G7
AC1 Resitive Rating
175 Amp
AC3 Inductive Rating
115 Amp
AC3 Single Phase 115V
N/A
AC3 Single Phase 230V
N/A
AC3 Three Phase 200V
30 HP
AC3 Three Phase 230V
40 HP
AC3 Three Phase 460V
75 HP
AC3 Three Phase 575V
100 HP
CE
Yes
Coil Consumption Inrush
280 - 350 VA
Coil Consumption Sealed
2 - 18 VA
Coil Voltage
120Vac 50/60 Hz
Contact Rating
600V/115A
Control Contact Rating (1NC/0NO)
A600
Control Terminal Torque
10 lb-in (1.2 Nm)
Control Wire Size
#14 - #18 AWG
CSA File
LR43364 3211 04
Meets Standard
IEC 60647-4
Mounting Hardware
2 x 35mm DIN Rail, M6 screw
Power Terminal Torque
100 lb-in (12 Nm)
RoHS
Yes
Termination Method
Screw Clamp
UL File/CCN
E164862/NLDX
Weight
2.5 lb (1.13 kg)
Features
- 3 Pole
- 3-Pole Contactor with Built-In Auxiliary Contacts
- 30 Hp At 200 Vac, 40 Hp At 230 Vac, 75 Hp At 460 Vac, 100 Hp At 575 Vac 3 Phase
- Approval Ul, Csa, Ase, Bv, Demko, Dnv, Fi, Nemko, Rina, Rrs, Semko
- Authentic Square D Product
- Auxiliary Contact 1No-1Nc
- Coil Voltage 120 Vac At 50/60 Hz
- DIN Rail or Panel Mount
- Iec Construction Standard
- Inductive Current 115 Ampere (Ac-3)
- IP20 Touch-Safe Terminals on the Contactors
- Lc1D Model
- Non Reversing
- Open
- Resistive Current 200 Ampere (Ac-1)
- Tesys[R] Brand
Datasheet
Extracted Text
IEC CONTACTORS AND 18 STARTERS ® Contactors & TeSys D Non-reversing Overload Relays Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.1: 3- or 4-Pole Screw Terminal Connections Maximum Current Instantaneous Maximum Horsepower Ratings Utilization No of Poles Auxiliary $ Price Categories Contacts Catalog Number a Single Phase Three Phase Inductive Resistive AC3 AC1 N.O. N.C. N.O. N.C. 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp AC Coils DC Coils Amperes Amperes 0.51 2 2 57.5 9 3 LC1D09 cde 94.00 119.00 0 —— —— —— — 20 4 11 LC1DT20 c 94.00 119.00 —— —— —— — 2 2 LC1D098 c 94.00 119.00 LC1D09 123 3 7.5 10 12 3 LC1D12 cde 119.00 149.00 0 —— —— —— — 25 4 11 LC1DT25 c 119.00 149.00 —— —— —— — 2 2 LC1D128 c 119.00 149.00 135 5 10 15 18 3 LC1D18 cd 136.00 160.00 0 —— —— —— — 32 4 11 LC1DT32 c 149.00 183.00 —— —— —— — 2 2 LC1D188 c 149.00 183.00 2 3 7.5 7.5 15 20 25 3 LC1D25 cd 151.00 181.00 0 —— —— —— — 40 4 11 LC1DT40 c 193.00 240.00 —— —— —— — 2 2 LC1D258 c 193.00 240.00 2 5 10 10 20 30 32 50 3 0 1 1 LC1D32 cd 172.00 213.00 3 5 10 10 30 30 40 3 1 1 LC1D40A 218.00 275.00 60 0 —— —— —— — 4 0 0 LC1DT60A 296.00 353.00 3 7.5 15 15 40 40 50 3 LC1D50A 234.00 291.00 01 1 LC1D093 5 1020204050 65 80 3 LC1D65A 322.00 379.00 —— —— —— — 4 0 0 0 LC1DT80A 446.00 503.00 7.5 1525306060 80 3 1 1 LC1D80 363.00 420.00 0 —— —— —— — 125 4 LC1D80004 b 489.00 524.00 00 —— —— —— — 2 2 LC1D80008 b 489.00 524.00 — — 30 40 75 100 115 3 LC1D115 479.00 479.00 11 — — 40 50 100 125 150 200 3 0 LC1D150 696.00 696.00 — — — — — — — 4 0 0 LC1D115004 630.00 630.00 a Complete catalog number with coil voltage code from table on page 18-6; example, LC1D09G7. b For DC version of these devices replace the 'C' with 'P' (ex. LC1D80004** becomes LP1D80004**). This applies only to 80A 4 pole devices. c On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification. d On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power LC1D40A terminations). No price adder for this modification. e On LC1D09 and LC1D12 only, for slip-on connector versions add "9" to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D099G7). No price adder for this modification. Table 18.2: TeSys D Overload Relays — Ambient Compensated, Bi-Metallic Direct Mount Class 10 with Class 10 without Class 20 with Class 20 without Current Setting For Direct Mounting Single Phase Single Phase Single Phase Single Phase $ Price Range Amperes to LC1... Sensitivity Sensitivity Sensitivity Sensitivity 0.10–0.16 LRD01 LR3D01 —— 0.16–0.25 LRD02 LR3D02 —— 0.25–0.40 LRD03 LR3D03 —— 0.40–0.63 LRD04 LR3D04 —— 0.63–1 D09–D32 LRD05 LR3D05 —— 60.00 1–1.6 LRD06 LR3D06 —— 1.6–2.5 LRD07 LR3D07 —— LC1D115 2.5–4 LRD08 LR3D08 LRD1508 LR3D1508A1 4–6 LRD10 LR3D10 LRD1510 LR3D1510A1 5.5–8 D09–D32 LRD12 LR3D12 LRD1512 LR3D1512A1 7–10 D09–D32 LRD14 LR3D14 LRD1514 LR3D1514A1 9–13 D12–D32 LRD16 LR3D16 LRD1516 LR3D1516A1 62.00 12–18 D18–D32 LRD21 LR3D21 LRD1521 LR3D1521A1 16–24 D25–D32 LRD22 LR3D22 —— 17–25 D25–D32 — — LRD1522 LR3D1522A1 23–32 D25–D32 LRD32 LR3D32 —— 23–28 D25–D32 — — LRD1530 LR3D1530A1 73.00 25–32 D25–D32 — — LRD1532 LR3D1532A1 30–38 D32 LRD35 LR3D35 —— 9-13 D40A-D65A f LRD313 LR3D313 LRD313L — LRD22 12-18 D40A-D65A f LRD318 LR3D318 LRD318L — 16-25 D40A-D65A f LRD325 LR3D325 LRD325L — 23-32 D40A-D65A f LRD332 LR3D332 LRD332L — 107.00 30-40 D40A-D65A f LRD340 LR3D340 LRD340L — 37-50 D40A-D65A f LRD350 LR3D350 LRD350L — 48-65 D40A-D65A f LRD365 LR3D365 LRD365L — 17-25 D40-D80 g LRD3322 LR3D3322 LR2D3522 LR3D3522 23-32 D40-D80 g LRD3353 LR3D3353 LR2D3553 LR3D3553 30-40 D40-D80 g LRD3355 LR3D3355 LR2D3555 LR3D3555 107.00 37-50 D50-D80 g LRD3357 LR3D3357 LR2D3557 LR3D3557 48-65 D50-D80 g LRD3359 LR3D3359 LR2D3559 LR3D3559 55–70 D65–D80 LRD3361 LR3D3361 LR2D3561 LR3D3561 63–80 D65–D80 LRD3363 LR3D3363 LR2D3563 LR3D3563 127.00 LRD3 80–104 D80 LRD3365 —— — 80–104 D115–D150 LRD4365 —— — 95–120 D115–D150 LRD4367 —— — 362.00 E164862 110–140 D150 LRD4369 —— — CCN NLDX f Overload relays with Everlink termination - direct mount to D40A to D65A only. g Direct mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only. LR43364 TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 Class 3211 04 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91 © 2009 Schneider Electric 18-4 Discount I12 Schedule All Rights Reserved IEC CONTACTORS AND 18 STARTERS ® 3 Pole Contactors TeSys D AC and DC Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us LC _____ D _____ _____ _____ _____ Full Voltage, Non-Reversing 1 Full Voltage, Reversing 2 TeSys D 3 Pole Contactors 9A to 150A Contactor AC-3 Full Load Amps (FLA) 9A FLA 09 12A FLA 12 18A FLA 18 25A FLA 25 32A FLA 32 38A FLA (not marketed in US) 38 40A FLA 40 50A FLA 50 65A FLA 65 80A FLA 80 95A FLA (not marketed in US) 95 115A FLA 115 150A FLA 150 Everlink Power Connection (40A to 65A only) A No Everlink Power Connection (9A to 32A, 80A to 150A) Blank Termination Options (choose one) Screw Termination Blank Spring Terminations s 3 Ring Tongue Terminations t 6 Slip-on Terminations (9A to 12A only) 9 Coil Voltage (choose one) DC Coils AC Coils (50/60 Hz) DC Coils (standard) low consumption available for 9 to 38 amp only 12V J7 12V JD 5V AL 21V Z7 21V ZD 12V JL 24V B7 24V BD 21V ZL 36V C7 36V CD 24V BL 42V D7 48V ED 48V EL 48V E7 60V ND 72V SL 60V EE7 72V SD 96V DL 100V K7 110V FD 110V FL 110V F7 125V GD 220V ML 115V FE7 220V MD 250V UL 120V G7 250V UD 127V FC7 440V RD 200V L7 208V LE7 220V M7 230V P7 240V U7 277V W7 380V Q7 400V V7 415V N7 440V R7 480V T7 500V S7 575V SC7 600V X7 Y5 660V (50 Hz only) s On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power terminations). No price adder for this modification. t On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification. Note: To be used for interpretation of current catalog numbers only. © 2009 Schneider Electric 18-2 All Rights Reserved
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the LC1D115G7?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

Schneider Electric LADLVRT24V 24V Low Voltage Ride Through Module; Used On Tesys[T] Lc1d/Cad Series ...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods