Industrial Trading chervon right Manufacturers chervon right S chervon right SCHNEIDER ELECTRIC chervon right LC1D093
About product Features Datasheet FAQ

SCHNEIDER ELECTRIC LC1D093

Image of SCHNEIDER ELECTRIC LC1D093

Description

Schneider Electric LC1D093 9A, 24V DC Coil Contactor

Part Number

LC1D093

Price

Request Quote

Manufacturer

SCHNEIDER ELECTRIC

Lead Time

Request Quote

Category

None

Features

Datasheet

pdf file

Schneider Electric-LC1D093-datasheet1-751588918.pdf

883 KiB

Extracted Text

IEC CONTACTORS AND 18 STARTERS ® 3 Pole Contactors TeSys D AC and DC Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us LC _____ D _____ _____ _____ _____ Full Voltage, Non-Reversing 1 Full Voltage, Reversing 2 TeSys D 3 Pole Contactors 9A to 150A Contactor AC-3 Full Load Amps (FLA) 9A FLA 09 12A FLA 12 18A FLA 18 25A FLA 25 32A FLA 32 38A FLA (not marketed in US) 38 40A FLA 40 50A FLA 50 65A FLA 65 80A FLA 80 95A FLA (not marketed in US) 95 115A FLA 115 150A FLA 150 Everlink Power Connection (40A to 65A only) A No Everlink Power Connection (9A to 32A, 80A to 150A) Blank Termination Options (choose one) Screw Termination Blank Spring Terminations s 3 Ring Tongue Terminations t 6 Slip-on Terminations (9A to 12A only) 9 Coil Voltage (choose one) DC Coils AC Coils (50/60 Hz) DC Coils (standard) low consumption available for 9 to 38 amp only 12V J7 12V JD 5V AL 21V Z7 21V ZD 12V JL 24V B7 24V BD 21V ZL 36V C7 36V CD 24V BL 42V D7 48V ED 48V EL 48V E7 60V ND 72V SL 60V EE7 72V SD 96V DL 100V K7 110V FD 110V FL 110V F7 125V GD 220V ML 115V FE7 220V MD 250V UL 120V G7 250V UD 127V FC7 440V RD 200V L7 208V LE7 220V M7 230V P7 240V U7 277V W7 380V Q7 400V V7 415V N7 440V R7 480V T7 500V S7 575V SC7 600V X7 Y5 660V (50 Hz only) a On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power terminations). No price adder for this modification. b On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification. Note: To be used for interpretation of current catalog numbers only. © 2009 Schneider Electric 18-2 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC CONTACTORS AND 18 STARTERS ® Contactors & TeSys D Non-reversing Overload Relays Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.1: 3- or 4-Pole Screw Terminal Connections Maximum Current Instantaneous Maximum Horsepower Ratings Utilization No of Poles Auxiliary $ Price Categories Contacts Catalog Number a Single Phase Three Phase Inductive Resistive AC3 AC1 N.O. N.C. N.O. N.C. 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp AC Coils DC Coils Amperes Amperes 0.51 2 2 57.5 9 3 LC1D09 cde 94.00 119.00 0 —— —— —— — 20 4 11 LC1DT20 c 94.00 119.00 —— —— —— — 2 2 LC1D098 c 94.00 119.00 LC1D09 123 3 7.5 10 12 3 LC1D12 cde 119.00 149.00 0 —— —— —— — 25 4 11 LC1DT25 c 119.00 149.00 —— —— —— — 2 2 LC1D128 c 119.00 149.00 135 5 10 15 18 3 LC1D18 cd 136.00 160.00 0 —— —— —— — 32 4 11 LC1DT32 c 149.00 183.00 —— —— —— — 2 2 LC1D188 c 149.00 183.00 2 3 7.5 7.5 15 20 25 3 LC1D25 cd 151.00 181.00 0 —— —— —— — 40 4 11 LC1DT40 c 193.00 240.00 —— —— —— — 2 2 LC1D258 c 193.00 240.00 2 5 10 10 20 30 32 50 3 0 1 1 LC1D32 cd 172.00 213.00 3 5 10 10 30 30 40 3 1 1 LC1D40A 218.00 275.00 60 0 —— —— —— — 4 0 0 LC1DT60A 296.00 353.00 3 7.5 15 15 40 40 50 3 LC1D50A 234.00 291.00 01 1 LC1D093 5 1020204050 65 80 3 LC1D65A 322.00 379.00 —— —— —— — 4 0 0 0 LC1DT80A 446.00 503.00 7.5 1525306060 80 3 1 1 LC1D80 363.00 420.00 0 —— —— —— — 125 4 LC1D80004 b 489.00 524.00 00 —— —— —— — 2 2 LC1D80008 b 489.00 524.00 — — 30 40 75 100 115 3 LC1D115 479.00 479.00 11 — — 40 50 100 125 150 200 3 0 LC1D150 696.00 696.00 — — — — — — — 4 0 0 LC1D115004 630.00 630.00 a Complete catalog number with coil voltage code from table on page 18-6; example, LC1D09G7. b For DC version of these devices replace the 'C' with 'P' (ex. LC1D80004** becomes LP1D80004**). This applies only to 80A 4 pole devices. c On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification. d On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power LC1D40A terminations). No price adder for this modification. e On LC1D09 and LC1D12 only, for slip-on connector versions add "9" to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes LC1D099G7). No price adder for this modification. Table 18.2: TeSys D Overload Relays — Ambient Compensated, Bi-Metallic Direct Mount Class 10 with Class 10 without Class 20 with Class 20 without Current Setting For Direct Mounting Single Phase Single Phase Single Phase Single Phase $ Price Range Amperes to LC1... Sensitivity Sensitivity Sensitivity Sensitivity 0.10–0.16 LRD01 LR3D01 —— 0.16–0.25 LRD02 LR3D02 —— 0.25–0.40 LRD03 LR3D03 —— 0.40–0.63 LRD04 LR3D04 —— 0.63–1 D09–D32 LRD05 LR3D05 —— 60.00 1–1.6 LRD06 LR3D06 —— 1.6–2.5 LRD07 LR3D07 —— LC1D115 2.5–4 LRD08 LR3D08 LRD1508 LR3D1508A1 4–6 LRD10 LR3D10 LRD1510 LR3D1510A1 5.5–8 D09–D32 LRD12 LR3D12 LRD1512 LR3D1512A1 7–10 D09–D32 LRD14 LR3D14 LRD1514 LR3D1514A1 9–13 D12–D32 LRD16 LR3D16 LRD1516 LR3D1516A1 62.00 12–18 D18–D32 LRD21 LR3D21 LRD1521 LR3D1521A1 16–24 D25–D32 LRD22 LR3D22 —— 17–25 D25–D32 — — LRD1522 LR3D1522A1 23–32 D25–D32 LRD32 LR3D32 —— 23–28 D25–D32 — — LRD1530 LR3D1530A1 73.00 25–32 D25–D32 — — LRD1532 LR3D1532A1 30–38 D32 LRD35 LR3D35 —— 9-13 D40A-D65A f LRD313 LR3D313 LRD313L — LRD22 12-18 D40A-D65A f LRD318 LR3D318 LRD318L — 16-25 D40A-D65A f LRD325 LR3D325 LRD325L — 23-32 D40A-D65A f LRD332 LR3D332 LRD332L — 107.00 30-40 D40A-D65A f LRD340 LR3D340 LRD340L — 37-50 D40A-D65A f LRD350 LR3D350 LRD350L — 48-65 D40A-D65A f LRD365 LR3D365 LRD365L — 17-25 D40-D80 g LRD3322 LR3D3322 LR2D3522 LR3D3522 23-32 D40-D80 g LRD3353 LR3D3353 LR2D3553 LR3D3553 30-40 D40-D80 g LRD3355 LR3D3355 LR2D3555 LR3D3555 107.00 37-50 D50-D80 g LRD3357 LR3D3357 LR2D3557 LR3D3557 48-65 D50-D80 g LRD3359 LR3D3359 LR2D3559 LR3D3559 55–70 D65–D80 LRD3361 LR3D3361 LR2D3561 LR3D3561 63–80 D65–D80 LRD3363 LR3D3363 LR2D3563 LR3D3563 127.00 LRD3 80–104 D80 LRD3365 —— — 80–104 D115–D150 LRD4365 —— — 95–120 D115–D150 LRD4367 —— — 362.00 E164862 110–140 D150 LRD4369 —— — CCN NLDX f Overload relays with Everlink termination - direct mount to D40A to D65A only. g Direct mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only. LR43364 TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 Class 3211 04 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91 © 2009 Schneider Electric 18-4 Discount I12 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® Contactors & TeSys F Non-reversing Overload Relays Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.3: TeSys D Overload Relays — Solid State For Direct Mounting Beneath Current Setting Range Amperes Class 10 Class 20 $ Price Contractor LC1 60–100 D115–D150 LR9D5367 LR9D5567 298.00 90–150 D115–D150 LR9D5369 LR9D5569 298.00 Table 18.4: TeSys F 2-, 3-, and 4-Pole Contactors Standard power ratings of 3-phase motors 50/60 Hz in Catalog Maximum Current category AC-3 Number a Number of 200 V 220 V 460 V 575 V $ Price AC-3 AC-1 Poles 208 V 240 V 480 V 600 V Panel Mount with Screws HP HP HP HP A A 3LC1F115 479.00 30 40 75 100 115 200 4LC1F1154 630.00 3LC1F150 696.00 40 50 100 125 150 250 4LC1F1504 825.00 3LC1F185 938.00 50 60 125 150 185 275 4LC1F1854 1439.00 LC1F115 3LC1F225 1059.00 Current Rated 225 315 4LC1F2254 1935.00 3LC1F265 1179.00 60 75 150 175 265 350 4LC1F2654 1646.00 3LC1F330 1621.00 75 100 200 250 330 400 4LC1F3304 1846.00 2LC1F4002 1521.00 100 125 250 300 400 500 3LC1F400 1874.00 4LC1F4004 2133.00 2LC1F5002 4324.00 150 200 400 500 500 700 3LC1F500 4970.00 4LC1F5004 5617.00 2LC1F6302 5917.00 250 300 600 800 630 1000 3LC1F630 6474.00 4LC1F6304 7582.00 3LC1F780 7788.00 Current Rated 780 1600 4LC1F7804 9940.00 — 450 800 900 800 1000 3 LC1F800 6676.00 a Complete part number by adding coil voltage code from table below. For example: LC1F115G7. All contactors (except F780) include 1 N.O. coil interlock contact. Table 18.5: TeSys F 3-Phase Overload Relays — Solid State Separate Mount b Current Setting Range For Direct Mounting to Contactor Class 10 Trip c Class 20 c $ Price Amps LC1●●●● Catalog Number Catalog Number 30–50 F115–F185 LR9F5357 LR9F5557 298.00 48–80 F115–F185 LR9F5363 LR9F5563 298.00 60–100 F115–F185 LR9F5367 LR9F5567 298.00 90–150 F115–F185 LR9F5369 LR9F5569 298.00 132–220 F185 d –F265 LR9F5371 LR9F5571 298.00 200–330 F265–F500 LR9F7375b LR9F7575b 333.00 300–500 F265–F500 LR9F7379b LR9F7579b 737.00 380–630 F400–F630 LR9F7381b LR9F7581b 905.00 b When mounting overload relays LR9F5●57 to LR9F5●71 directly beneath the contactor, supporting the relays with a mounting plate is recommended. With overload relays LR9F7●75 to LR9F7●81, use of a support mounting plate is mandatory. c IEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current: Class 10 — between 4 and 10 seconds Class 20 — between 6 and 20 seconds d Interconnection kit LA7F407 is required to mount an LR9F●71 to an LC1F185. Table 18.6: Coil Voltage Codes h Contactor Hz 24 V 48 V 110 V 120 V 125 V 208 V 220 V 240 V 250 V 440 V 480 V 600 V AC D09–D150 50/60 B7 E7 F7 G7 — LE7 M7 U7 — — T7 e X7 ef 60 B6 E6 F6 G6 — L6 M6 U6 — — T6 X6 f LC1D80–LC1D150 only 50 B5 E5 F5 — — — M5 e U5 ——— — 50 B5 E5 F5 ——— M5 U5 ——— — F115, F150, and F185 60 B6 E6 F6 G6 — L6 M6 U6 — — Q5 SC F265, and F330 40–400 B7 E7 F7 G7 — L7 M7 U7 — — S7i X7 F400— F780 40–400 — E7 F7 G7 — L7 M7 U7 — — N7 X7 g DC D09-D32, DT20-D258 — BL EL FL ——— ML — UL —— — Low Consumption D09–D150 — BD ED FD — GD — MD — UD RD — — F115-F330 — BD ED FD — GD — MD — UD RD — — F400–F780 — — ED FD — GD — MD — UD RD — — e Not available for LC1D80 - LC1D150 f Not available for LC1D115 or LC1D150 g Not available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits. h For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901. i For use with F265—F330 only. Table 18.7: Coil Voltage Codes for AC and DC Voltages for F800 (includes built-in surge suppressor) E164862 Volts AC/DC 24 48 110 120 127 208 220 240 277 380 415 440 480 575 600 660 CCN NLDX 50/60 HZ — — FW FW FW — MW MW — QW QW QW — — — — LR43364 TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-11 Class 3211 04 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49 © 2009 Schneider Electric Discount 18-5 I12 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC CONTACTORS AND 18 STARTERS IEC CONTACTORS AND 18 STARTERS ® Contactor TeSys D & F Auxiliary Contacts, Time Delay, Mechanical Latch Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.15: Standard, instantaneous auxiliary contact blocks Composition Snap-On Number of Catalog Number a $ Price Mounting Contacts N.O. N.C. 22 LADN22 b 41.50 13 LADN13 b 41.50 40 LADN40 b 41.50 To front of 4 a LC●DT20–D258 (4P), 04 LADN04 b 41.50 LC●D09–D150a 31 LADN31 b 41.50 or 2 c 2 c LADC22 bc 41.50 To right side of LC●F 11 LADN11 b 20.70 2 20 LADN20 b 20.70 02 LADN02b 20.70 To front of LC●D80 and D115 or 1 To left side of 10 LADN10 d 13.10 Front Mounted LC●F 01 LADN01 d 13.10 Auxiliary Blocks (shown on TeSys D To side of LC●D09 to D150 only 21 1 LAD8N11 e 20.70 contactor) (not for use on TeSys F) 20 LAD8N20 e 20.70 a For low consumption coils (LC1D09 to D32 only), only one front-mounted two-contact block allowed. No side- mounted contact blocks allowed. b For spring terminal versions of these blocks, add a “3” to the end of the catalog number. (Ex. LADN223). No price adder for this modification. c Including 1 N.O. + 1 N.C. make before break overlapping contacts. d This block cannot be added to the LC1D 09 to D32 contactors; a maximum of 2 blocks can be mounted on the LC1D40A to LC1/LP1D80 contactors only. e 1 block may be added to the left side of the LC1D 09 to D32, AC coils only; 1 block may be added to each side of the LC1D 40A to D80 contactors, AC coils only. Cannot be installed on TeSys D contactors with DC coils. Table 18.16: Instantaneous blocks with dust-tight auxiliary contacts (IP54) NEMA 12 Standard Contacts Dusttight Contacts Snap-On Catalog Number $ Price Mounting N.O. N.C. N.O. N.C. To front of —— 2 — LA1DX20 65.00 LP●D40–D80, LC●DT20–D258 (4P), 2— 2 — LA1DZ40 82.00 LC●D09 to D80 11 2 — LA1DZ31 82.00 or To right side of —— 2 — LA1DY20f 77.00 LC●F f Device supplied with 4 ground terminal points. Table 18.17: Pneumatic time delay contact blocks Time Delay Snap-On Range of Catalog Contacts Type $ Price Mounting Time Delay Number h N.O. N.C. 0.1 to 3 sg LADT0 131.00 To front of 0.1 to 30 s LADT2 131.00 On energization LP●D40–D80, 11 (on delay) 10 to 180 s LADT4 131.00 LC●DT20–D258 (4P), LC●D09 to D150 1 to 30 si LADS2 131.00 or 0.1 to 3 sg LADR0 131.00 To right side of On de-energization 11 0.1 to 30 s LADR2 131.00 LC●F (off-delay) 10 to 180 s LADR4 131.00 g Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. h For spring terminal versions of these blocks, add a “3” to the end of the catalog number. (Ex. LADT23). No price adder for this modification. i With switching time of 40 ms ± 15 ms between the opening of the N.C. contact to the closing of the N.O. contact. Table 18.18: Mechanical latch blocks with manual or electrical unlatch (TeSys D only) Catalog number Front snap-on to be completed Application $ Price mounting onto by the code corresponding to the coil voltage For silent operation and energy LC●D09 to D65A LAD6K10jk 77.00 conservation For silent operation and energy LC1 D80 to D150 LP1 D80 LA6DK20jk 77.00 conservation j Does not include internal coil clearing contact. k Complete catalog number by adding coil voltage code. For example: LAD6K10F. Table 18.19: Coil Voltage Codes for LA6DK mechanical latch blocks 110/ 200/ 220/ 380/ 440/ 500/ Volts 12 24 32/36 42/48 60/72 100 127 208 240 415 480 600 AC or DC J B C E EN K F L M Q R S TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 E164862 CCN NLDX LR43364 Class 3211 04 © 2009 Schneider Electric 18-8 Discount I12 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® Contactor Accessories TeSys D Coil Suppressors, Cabling Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us RC Coil Suppressor Limitation of transient voltage to 300% of nominal voltage maximum Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times normal) Table 18.20: Resistor/capacitor circuit (RC) for reduction of “electrical noise” in AC contactor coils Installed by Mounting on Operating voltage 50/60 Hz Catalog Number $ Price 24–28 V LAD4RCE 26.20 LA4DA1U LC1D09 to LC1D32 (3P) Snapping into cavity on right side without toolsb 50–127 V LAD4RCG 26.20 LC●DT20 to DT40 (4P), 110–240 V LAD4RCU 26.20 24-48 V LAD4RC3E 26.20 LC1D40A to LC1D65A (3P), 50-127 V LAD4RC3G 26.20 Snap-on mounting and connection without tools to the LC1DT60A to LC1DT80A contactor coil terminals 110-240 V LAD4RC3U 26.20 (4P) 380-415 V LAD4RC3N 26.20 24–48 V LA4DA2E 26.20 50–127 V LA4DA2G 26.20 LC●D80 to D150 (3 or 4P) Screw connection to the contactor coil terminals LC●D80 to D115 (4P) 110–240 V LA4DA2U 26.20 380–415 V LA4DA2N 26.20 Varistor Coil Suppressor Limitation of transient voltage value to 200% of nominal voltage maximum Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times normal) Table 18.21: Varistor (peak limiting) for reduction of “electrical noise” in AC or DC contactor coils LA4DA2U Installed by Mounting on Operating voltage 50/60 Hz Catalog Number $ Price 24–48 V LAD4VE 26.20 LC●D09 to D32a Snapping into cavity on right side without toolsb 50–127 V LAD4VG 26.20 TeSys D contactors 110–250 V LAD4VU 26.20 24-48 V LAD4V3E 26.20 LC1D40A to LC1D65A (3P), Snap-on mounting and connection without tools to the LC1DT60A to LC1DT80A 50-127 V LAD4V3G 26.20 contactor coil terminals (4P) 110-250 V LAD4V3U 26.20 24–48 Vac LA4DE2E 26.20 LC●D80 to D115 (3P or 4P) Screw connection to the contactor coil terminals 50–127 Vac LA4DE2G 26.20 LC●D12, D25 (4P) 110–250 Vac LA4DE2U 26.20 24–48 Vdc LA4DE3E 26.20 Screw connection to the contactor coil terminals LC●D80 (3P or 4P) 50–127 Vdc LA4DE3G 26.20 110–250 Vdc LA4DE3U 26.20 a For DC coils 3-pole contactors are fitted with built-in surge suppression as standard. Diode Coil Suppressor No overvoltage or oscillating frequency Polarized component. Increased drop-out time (6 to 10 times normal) Table 18.22: Diode for reduction of “electrical noise” in DC contactor coils Installed on the upper part by Mounting on Operating voltage DC Catalog Number $ Price Snap-on mounting and connection w/o tools to the contactor coil terminals LC●D09 - D32 24–250 V LAD4DDL 26.20 LC●D40A to D65, Clip-on front mounting 24–250 V LAD4D3U 26.20 D65A to DT80A D80 (3P) Screw connection of wire to the contactor coil terminals 24–250 V LA4DC3U 26.20 LA4DC3U D80 (4P) Bidirectional Diode Coil Suppressor Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks Table 18.23: Bidirectional peak limiting diode Installed by Mounting on Operating Voltage 50/60 Hz and DC Catalog Number $ Price 24 (AC only) LAD4TB 26.20 LC●D09 to LC●D32 (3P)c Snapping into cavity on right side of contactor b DT20 to DT40 (4P) 72 (AC only) LAD4TS 26.20 12 - 24 V LAD4T3B 26.20 25 - 72 V LAD4T3S 26.20 LC1D40A to LC1D65A (3P), Clip-on front mounting and connection without tools LC1DT60A to LC1DT80A 73 - 125 V LAD4T3G 26.20 to the contactor coil terminals c (4P) 126 - 250 V LAD4T3U 26.20 251 - 440 V LAD4T3R 26.20 24 (AC only) LA4DB2B 56.00 72 (AC only) LA4DB2S 26.20 Screw Mounting d LC●D80 24 (DC only) LA4DB3B 56.00 72 (DC only) LA4DB3S 56.00 b Installing suppressor into the cavity makes the electrical connection. Overall width of contactor remains the same. c For LC●D09 through LC●D65A with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as standard. d Mounting at the top of the contactor on coil terminals A1 and A2. Table 18.24: Cabling Accessories Usage Mounting on Operating voltage 50/60 Hz Catalog Number $ Price Without coil suppression LAD4BB 23.00 LC1D09 to D38 24-48 V LAD4BBVE 23.00 For adapting existing wiring to a new product or for use with With coil LC1DT20 to DT60 top mount accessory. suppression 50-127 V LAD4BBVG 23.00 AC only (varistor) 110-250 V LAD4BBVU 23.00 For adapting existing wiring to a new product or for use with LC1D40A to LC1D65A — LAD4BB3 26.20 top mount accessory (with no coil suppressor) LAD4BB TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 © 2009 Schneider Electric Discount 18-9 I12 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC CONTACTORS AND 18 STARTERS IEC CONTACTORS AND 18 STARTERS ® Contactor Accessories TeSys D Electronic Timers and Interface Modules Refer to Catalog 8502CT9901 www.schneider-electric.us The following accessories require use of cabling accessories (LAD4BB●●) for proper mounting. See page 18-9 for illustration. Electronic Serial Timer Modules These solid state modules delay the energizing and de-energizing of the contactor coil. Table 18.25: Operational Voltage a Type Time Delay Catalog Number $ Price 24–250 Vac 100–250 Vac 0.1–2 s LA4DT0U 82. On-delay LC1D09–D65A LC1D80–D150 1.5–30 s LA4DT2U 82. 25–500 s LA4DT4U 82. a For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; ZD for DC. Interface Modules b These modules allow the contactor coils to be energized from low voltage and low current level signals. They come in mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manually turning the contactor on and off. When a module receives a low level signal, it allows the separate sourced control voltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays. Table 18.26: Operational Voltage Interface Type Input Voltage Catalog Number $ Price 24–250 Vac 100–250 Vac LC1D09–D150 24 Vdc LA4DFB 55. Relay LC1D09–D150 48 Vdc LA4DFE 55. Relay Plus LC1D09–D150 24 Vdc LA4DLB 71. Manual Operation LC1D09–D150 48 Vdc LA4DLE 71. Solid State LC1D09–D65 LC1D80–D115 24 Vdc LA4DWB 71. LA4DFB b Adapter required for D09 - D65A, see table 18.24. Automatic-Manual-Stop Control Modules These modules allow for local and/or remote operation of the contactor coil. Each module includes a lever to switch from automatic to manual operation and a dial to turn the contactor on and off. Table 18.27: Operational Voltage Catalog Number $ Price 24–100 Vac 100–250 Vac LC1D09–D150 — LA4DMK 35. Low Voltage Ride Through Module (meets SEMI F47 requirements) By ensuring SEMI F47 compliance of AC powered IEC contactors and relays, the low voltage ride through modules can be used to increase the voltage sag immunity of semiconductor processing equipment. These modules make it possible for AC powered Telemecanique contactors and relays to exceed the requirements of SEMI F47, both in the magnitude and duration of a voltage sag event—even with accessories such as auxiliary contact blocks and pneumatic timers. The low voltage ride through modules can be used with Telemecanique contactors from 9 A through 80 A, as well as the CAD series of control relays Table 18.28: For use on: Catalog Number $ Price Contactor Relay LC1D●●B7 CAD●●B7 LADLVRT24V c 124. LC1D●●G7 CAD●●G7 LADLVRT120V c 124. LC1D●●LE7 CAD●●LE7 LADLVRT208V c 124. Top mount bracket (required when using above modules) D09 - D32 LAD4BB c 23. Top mount bracket (required when using above modules) D40 - D65 LAD4BB3 c 23. Fuse LA9D941 120. c LAD4BB must be used when the low voltage ride through module is being used with contactors 32 A and less, and TeSys CAD Series of Control Relays. The LAD4BB3 must be used with the D40 - D65A. See table 18.24 on page 18-10. TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 LADLVRT E2 E1 1.25 A2 32 LADLVRT A1 A2 E1 E2 A1 1.85 47 A1 A2 LAD4BB Contactors 32 A and less Contactors 40 A–80 A © 2009 Schneider Electric 18-10 Discount I12 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ® Contactor Accessories TeSys D and F Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.29: For Power Pole or Control Connection For use with Sold in Catalog Description contactors $ Price each lots of Number LC1/LP1 2 4 poles #8 AWG (10 mm )D09, D12 1 LAD92560 8.70 Connectors for 2 larger cable sizes 3 poles #4 AWG (25 mm ) D09–D32 1 LA9D3260 12.00 Everlink® terminal 3 poles D40A-D65A 1 LAD96560 10.00 block LA9D1260 D09–D32 10 LA9D2561 26.20 D40A–D65A 1 LAD9P32 6.00 D80 2 LA9D80961 6.50 F115 4 LA9FF602 55.00 2 poles F150, F185 4 LA9FG602 65.00 F265, F330, F400 4 LA9FH602 169.00 F500 4 LA9FK602 228.00 F630, F800 4 LA9FL602 278.00 Links D09–D32 10 LAD9P3 10.00 for the parallel D40A-D65A 1 LAD9P33 25.00 connection of D80 1 LA9D80962 6.50 3 poles F115 1 LA9FF601 6.80 (Wye-Delta F150, F185 1 LA9FG601 8.20 Shorting Strap) F265, F330, F400 1 LA9FH601 12.00 LA9D2561 F500 1 LA9FK601 21.80 F630, F800 1 LA9FL601 38.20 DT20, DT25 2 LA9D1263 8.70 4 poles D80 2 LA9D80963 17.50 Second coil connection LP1D40–D80 10 LA9D09966 2.20 D115, D150 10 LA9D11567 4.00 Control circuit take-off from main pole D80 10 LA9D8067 5.50 Spreaders for increasing pole pitch to 45 mm D115, D150 3 GV7AC03 31.10 Table 18.30: For Marking For use with Sold in Catalog Description contactors $ Price each lots of Number LC1/LP1 4-pole contactors LA9D40961 Reference label holder snap-on 8 x 22 mm 100 LA9D92 .06 D80 - D115 D09-D65A, DT20-DT80A, Reference label holder snap-on 8 x 18 mm 3 poles 100 LAD90 .06 LADN, LADT, LADR Sheet of 300 labels self adhesive 7 x 21 mm For holder LA9D92 1 LA9D93 4.30 Table 18.31: For Mounting For use with Sold in Catalog Description contactors $ Price each lots of Number LC1/LP1 Set of shims for mounting LAD8N and LA8DN D80 1 LA9D511 9.80 Retrofit plate for replacement of LC1D40-D65 with D40A-D65A 1 LAD7X3 25.00 LC1D40A-D65A 35 mm DIN Rail – 2 meters long LC1D09 to D80 10 AM1DP200 5.20 Table 18.32: Replacement contacts For use with Catalog LA9D6567 $ Price contactors Number LC1D115 3 poles LA5D1158031 239.00 Three-pole LC1D150 3 poles LA5D150803 239.00 Four-pole LC1D115 4 poles LA5D115804 318.00 Table 18.33: Arc chambers For use with Catalog $ Price contactors Number LC1D115 3 poles LA5D11550 90.00 Three-pole LC1D150 3 poles LA5D15050 90.00 Four-pole LC1D115 4 poles LA5D115450 119.00 TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20 LA9D511 © 2009 Schneider Electric Discount 18-11 I12 Schedule All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC CONTACTORS AND 18 STARTERS IEC CONTACTORS AND 18 STARTERS ® Dimensions TeSys D Contactors, AC Coil Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.154: TeSys D Contactors AC Control Circuits LC1D09 to D18 (3-pole) and LC1DT12 to LC1DT40 (4 pole) LC1D25 to D38 (3-pole) Minimum electrical clearance Minimum electrical clearance Minimum electrical clearance Minimum electrical clearance 1.73 44 LA4 .39 c .39 c .39 c .39 c 10 10 c1 c1 10 10 c1 c1 .51 1.77 1.77 c2 c2 c2 13 45 c2 45 c3 c3 (LAD8) c3 c3 AC Coil DC Coil D09 to D18 D093 to D18 D099 to D189 D25 to D38 D183 and D323 DT20 and DT25DT203 and DT253 DT32 to DT40 DT323 and DT403 LC1 IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) AC coil, without add-on accessories 3.03 (77) 3.89 (99) 3.14 (80) 3.36 (85) 3.89 (99) 3.34 (85) 3.89 (99) 3.58 (91) 4.13 (105) b DC coil AC coil, with LAD4BB b 3.70 (94) 4.21 (107) 3.75 (95.5) 3.85 (98) 4.21 (107) 3.85 (98) — — — AC coil, with LA4D*2 b 4.33 (110) a 4.84 (123) a 4.30 (111.5) a 4.48 (114) a 4.84 (123) a 4.48 (114) — — — b1 AC coil, with LA4DF, DT b 4.68 (119) a 5.19 (132) a 4.76 (120.5) a 4.84 (123) a 5.19 (132) a 5.02 (129) — — — AC coil, with LA4DR, DW, DL b 4.96 (126) a 5.67 (139) a 5.0 (127.5) a 5.11 (130) a 5.47 (139) a 7.48 (190) — — — AC coil, without cover or add-on blocks 3.30 (84) 3.30 (84) 3.30 (84) 3.54 (90) 3.54 (90) 3.54 (90) 3.54 (90) 3.85 (98) 3.85 (98) AC coil, with cover, without add-on blocks 3.38 (86) 3.38 (86) 3.38 (86) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.93 (100) 3.93 (100) c DC coil, without cover or add-on blocks 3.66 (93) 3.66 (93) 3.66 (93) 3.89 (99) 3.89 (99) — — — — DC coil, with cover, without add-on blocks 3.76 (95) 3.76 (95) 3.76 (95) 3.97 (101) 3.97 (101) 3.90 (99) 3.90 (99) 4.21 (107) 4.21 (107) AC coil, with LADN or C (two or four contacts) 4.60 (117) 4.60 (117) 4.60 (117) 4.84 (123) 4.84 (123) 4.84 (123) 4.84 (123) 5.15 (131) 5.15 (131) c1 DC coil, with LADN or C (two or four contacts) 4.96 (126) 4.96 (126) 4.96 (126) 5.19 (132) 5.19 (132) 4.84 (123) 4.84 (123) 5.15 (131) 5.15 (131) AC coil, with LAD6K10 5.07 (129) 5.07 (129) 5.07 (129) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143) c2 DC coil, with LAD6K10 5.43 (138) 5.43 (138) 5.43 (138) 5.66 (144) 5.66 (144) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143) AC coil, with LADT,R,S 5.39 (137) 5.39 (137) 5.39 (137) 5.62 (143) 5.62 (143) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151) AC coil, with LADT,R,S and sealing cover 5.55 (141) 5.55 (141) 5.55 (141) 5.78 (147) 5.78 (147) 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (155) c3 DC coil with LADT,R,S 5.76 (146) 5.76 (146) 5.76 (146) 5.98 (152) 5.98 (152) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151) DC coil with LADT,R,S and sealing cover 5.90 (150) 5.76 (146) 5.76 (146) 6.14 (156) 6.14 (156) 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (155) a Including LAD4BB b Not applicable to devices with DC coils Table 18.155: AC Coil LC1D40, D50, D65 (3P), LC1D65004 (4P) LC1D80004 (4P) 4.49 114 4.92 125 5.75*(LA1) 6.02* (LA1) 2.95(3P)3.34(4P) 3.34(3P)3.78(4P) 146 .51 .51 .51 .51 153 85 96 13 75 13 13 85 13 6.50**(LA2, LA3, LA6 DK1) (LA8) (LA8) 6.77** (LA2, LA3, LA6 DK2) (LA8) (LA8) 165 172 xcept LA1DN10, DN01 = 136 *except LA1DN10, DN01 = 136 +4 mm with lead sealing device ** +4 mm with lead sealing device LC1 D40A…D65A (3P), LC1 DT60A…DT80A (4P) AC OR DC D40A…D65A DT60A…DT80A D40008 LC1 IN (mm) IN (mm) IN (mm) Minimum electrical clearance a 2.17 (55) 2.76 (70) 3.35 (85) with LA4 D2 — — 5.31 (135) with LA4 DB3 or LAD 4BB3 5.35 (136) — — b1 with LA4 DF, DT 6.18 (157) — 5.59 (142) with LA4 DM, DW, DL 6.54 (166) — 5.91 (150) without cover or add-on blocks 4.65 (118) 4.65 (118) 4.92 (125) c with cover, without add-on blocks 4.72 (120) 4.72 (120) — with LAD N (1 contact) — — 5.47 (139) c1 with LAD N or C (2 or 4 contacts) 5.91 (150) 5.91 (150) 5.79 (147) 0.47 c 12 c2 with LAD 6K10 or LA6 DK 6.42 (163) 6.42 (163) 6.26 (159) c1 with LAD T, R, S 6.73 (171) 6.73 (171) 6.57 (167) 0.49 a 0.49 c3 12.5 12.5 with LAD T, R, S and sealing cover 6.89 (175) 6.89 (175) 6.73 (171) c2 (LAD 8N) (LAD 8N) c3 © 2009 Schneider Electric 18-40 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com b 4.80 122 5.00 127 b 4.61 117 b1 5.20 (LA4 DA2, DE2) 132 5.59 (LA4 DF, DT) 142 5.91 (LA4 DM, DR, DW, DZ) b1 150 b 5.00 127 b 5.51 (LA4 DA2, DE2) 140 5.79 (LA4 DF, DT) 147 6.18 (LA4 DM, DR, DW, DZ) 157 ® Dimensions TeSys D Contactors, DC Coil Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.156: DC Coil LC1D40, D50, D65 (3P), LC1D650004, (4P) LC1D80 (3P), LC1D800004(4P) Minimum electrical clearance Minimum electrical clearance .47 7.13 .47 12 181 12 6.73 171 2.95(3P) 3.34(4P) 8.03* (LA1) 8.27* (LA1) 204 75 85 210 3.34 (3P) 3.78(4P) 8.78d (LA6 DK2, LA2, LA3) 9.02d (LA6 DK3, LA2, LA3) 8596 223 223 *except LA1DN10, DN01 = 136 *except LA1DN10, DN01 = 143 d + 4 mm with lead sealing device d + 4 mm with lead sealing device LC1D115, D150 Panel mounted with 1/4” screws LC1 D115 D1156 D150 D1506 c 5.12 (132) 4.53 (115) 5.12 (132) 4.53 (115) G (3-poles) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) cG = = G (4-poles) 5.12/5.67 (130/144) 5.12/5.67 (130/144) — — LC1D115, D150 LC1 C A 6.61c (LA2, LA3) D115, D150 5.12 (132) 4.72 (120) LA4 168 D115004 5.12 (132) 6.10 (155) D1156, D1506 4.53 (115) 4.72 (120) D1150046 4.53 (115) 6.10 (155) LA8 c a 5.91q (LA1) a With 2 or 4 contacts. 150 6.10 (LA6-DK20) b + 4 mm with sealing cover. 155 LR2D4 bimetallic overload relay LR9D solid-state overload relay Direct mounting beneath contactors Direct mounting beneath contactors LC1D115 and D150 LC1D115 and D150 5.20 d 4.72 5.20 d 4.72 132 120 132 120 35 mm DIN rail dimensions 35 mm DIN rail dimensions AM1DP200 and DR200 AM1DE and EDAM1DP200 and DR200 AM1DE and ED d 0.10 (2.5) .41 (10.5) d 0.10 (2.5) .41 (10.5) Note: All dimensions are in Inches (mm). © 2009 Schneider Electric 18-41 All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6.22 158 7.44 189 10.51 267 5.91 4.96 150 126 = 5.12 = 130 6.22 158 6.85 (LA4D2, D3) 174 7.28 (DF, DT) 185 7.40 (DM, DR, DW, DL) 188 5.20 (LA4 DC3) 132 5.47 (LA4 DF, DT) 139 5.75 (LA4 DM, DR, DW, DZ) 146 6.85 174 10.04 255 5.35 4.96 136 126 5.51 (LA4 DC3) 140 5.79 (LA4 DF, DT) 147 6.06 (LA4 DM, DR, DW, DZ) 154 IEC CONTACTORS AND 18 STARTERS

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the LC1D093?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Schneider Electric 26960 CIRCUIT BREAKER. UNDER VOLTAGE | 240V | C60

product

SCHNEIDER ELECTRIC-60110-MINIATURE CIRCUIT BREAKER 240V 10AMP

product

Schneider Electric CH321NRB switch fusible HD 240V 30A 3P NEMA3R/N

product

Schneider Electric CH361 safety switch 30A 3-POLE 600V fusible C

product

Schneider Electric CH361AWK switch fusible HD 600V 30A 3P NEMA12

product

Schneider Electric CH361DS switch fusible HD 30A 3P NEMA4,4X,5 STA