Industrial Trading chervon right Manufacturers chervon right S chervon right SCHNEIDER ELECTRIC chervon right LC1-D123
About product Datasheet FAQ

SCHNEIDER ELECTRIC LC1-D123

Image of SCHNEIDER ELECTRIC LC1-D123

Description

Schneider Electric LC1-D123 3-7.5HP, 12A, 110-120 VAC, 1NO Contactor

Part Number

LC1-D123

Price

Request Quote

Manufacturer

SCHNEIDER ELECTRIC

Lead Time

Request Quote

Category

Contactors

Datasheet

pdf file

Schneider Electric- LC1-D123-datasheet1-1388656722.pdf

341 KiB

Extracted Text

References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 3-pole contactors for connection by screw clamp terminals or connectors (1) Standard power ratings Rated Instantan- Basic reference. Weight of 3-phase motors opera- eous Complete with code indicating (4) 50/60 Hz in category AC-3 tional auxiliary control circuit voltage (2) (θ ≤ 60 °C) current contacts Fixing (3) in AC-3 220V 380V 660V 440 V 230V 400V 415V 440V 500V 690V 1000V up to kW kW kW kW kW kW kW A kg 2.2 4 4 4 5.5 5.5 – 9 11 LC1-D09// (5) 0.320 LC1-D09// 3 5.5 5.5 5.5 7.5 7.5 – 12 11 LC1-D12// (5) 0.325 4 7.5 9910 10 – 18 11 LC1-D18// (5) 0.330 5.5 11 11 11 15 15 – 25 11 LC1-D25// (5) 0.370 7.5 15 15 15 18.5 18.5 – 32 11 LC1-D32// (5) 0.375 9 18.5 18.5 18.5 18.5 18.5 – 38 11 LC1-D38// (5) 0.380 2 11 18.5 22 22 22 30 22 40 11 LC1-D40// (5) 1.400 15 22 25 30 30 33 30 50 11 LC1-D50// (5) 1.400 18.53037373737 37 65 11 LC1-D65// 1.400 LC1-D25// 22 37 45 45 55 45 45 80 11 LC1-D80// 1.590 25 45 45 45 55 45 45 95 11 LC1-D95//� 1.610 30 55 59 59 75 80 75 115 11 LC1-D115// 2.500 40 75 80 80 90 100 90 150 11 LC1-D150// 2.500 (1) 3-pole contactors for connection by lugs or bars Insert the digit 6 before the voltage code in the references selected above. Example: LC1-D09// becomes LC1-D096//. Accessories Auxiliary contact blocks and modules: see pages 2/16 to 2/23. (1) See note (1) on next page. (2) Control circuit voltages. LC1-D95// a.c. supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 500 LC1-D09...D150 (D115 and D150 coils with integral suppression device fitted as standard) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 – d.c. supply Volts 12 24 36 48 60 72 110 125 220 250 440 LC1-D09...D38 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc JD BD CD ED ND SD FD GD MD UD RD LC1-D40...D95 U 0.85…1.1 Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75…1.2 Uc JW BW CW EW – SW FW – MW – – LC1-D115 and D150 (coils with integral suppression device fitted as standard) U 0.75…1.2 Uc – BD – ED ND SD FD GD MD UD RD Low consumption Volts $ 5244872 LC1-D09...D38 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc AL BL EL SL For other voltages between 5 and 690 V, see pages 2/26 to 2/31. (3) LC1-D09 to D38: clip-on mounting on 35 mm � rail AM1-DP or screw fixing. LC1-D40 to D95 ": clip-on mounting on 35 mm or 75 mm � rail AM1-DL or screw fixing. LC1-D115// LC1-D40 to D95 $: clip-on mounting on 75 mm � rail AM1-DL or screw fixing. LC1-D115 and D150: clip-on mounting on 2 x 35 mm � rails AM1-DP or screw fixing. (4) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.160 kg for contactors LC1-D09 to D38, 0.785 kg for contactors LC1-D40 to D65 and 1 kg for contactors LC1-D80 and D95. (5) For purchase in bulk packs, see page i/7. Selection: Characteristics: Dimensions: Schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/44 to 2/47 pages 2/48 and 2/49 Schneider Electric 2/6 105517 810353 810352 810356 References TeSys contactors For motor control up to 15 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 3-pole contactors for connection by spring terminals (1) Standard power ratings Rated Instantan- Basic reference. Weight of 3-phase motors opera- eous Complete with code indicating (4) 50/60 Hz in category AC-3 tional auxiliary control circuit voltage (2) (θ ≤ 60 °C) current contacts Fixing (3) in AC-3 220V 380V 660V 440 V 230V 400V 415V 440V 500V 690V up to kW kW kW kW kW kW A kg 2.2 4 4 4 5.5 5.5 9 11 LC1-D093// (5) 0.320 3 5.5 5.5 5.5 7.5 7.5 12 11 LC1-D123// (5) 0.325 47.5991010 1811LC1-D183// (5) 0.330 LC1-D123// 5.5 11 11 11 15 15 25 11 LC1-D253// (5) 0.370 7.5 15 15 15 18.5 18.5 32 (6) 1 1 LC1-D323// (5) 0.375 3-pole contactors for connection by Faston connectors (1) 2 These contactors are fitted with Faston connectors: 2 x 6.35 mm on the power poles and 1 x 6.35 mm or 2 x 2.8 mm on the coil and auxiliary terminals. For contactors LC1-D09 and LC1-D12 only, replace the digit 3 with a 9 in the references selected above. Example: LC1-D093// becomes LC1-D099//. Accessories Auxiliary contact blocks and modules: see pages 2/16 to 2/23. LC1-D129// (1) 3-pole contactors LC1-D09 to D150 can be supplied without safety cover. To order, insert the digit 5 before the voltage code in the references selected from either above or the previous page. Examples: LC1-D09// becomes LC1-D095// LC1-D096// becomes LC1-D0965// LC1-D099// becomes LC1-D0995// LC1-D093// becomes LC1-D0935// (2) Control circuit voltages. a.c. supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 LC1-D09...D32 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 d.c. supply Volts 12 24 36 48 60 72 110 125 220 250 440 LC1-D09...D32 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts $ 524 48 72 LC1-D09...D32 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc AL BL EL SL For other voltages between 5 and 690 V, see pages 2/26 to 2/31. (3) LC1-D09 to D32: clip-on mounting on 35 mm � rail AM1-DP or screw fixing. (4) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.160 kg for contactors LC1-D09 to D32. (5) For purchase in bulk packs, see page i/7. (6) For use with power connection module LAD-34 or Quickfit technology outgoing terminal block LAD-33 (Available 4th Quarter 2001), see page 4/9. Selection: Characteristics: Dimensions: Schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/44 to 2/47 pages 2/48 and 2/49 Schneider Electric 2/7 810359 810358 References TeSys contactors For control in utilisation category AC-1, 25 to 200 A Control circuit: a.c., d.c. or low consumption 3-pole contactors for connection by screw clamp terminals or connectors (1) Non inductive loads Number Instantaneous Basic reference. Weigh maximum current of poles t (θ ≤ 60 °C) auxiliary Complete with code indicating (4) utilisation category contacts control circuit voltage (2) AC-1 Fixing (3) A kg 25 311 LC1-D09// (5) 0.320 or LC1-D12// (5) (6) 0.325 32 311 LC1-D18// (5) 0.330 LC1-D129// 40 311 LC1-D25// (5) 0.370 50 311 LC1-D32// (5) 0.375 or LC1-D38// (5) (6) 0.380 60 311 LC1-D40// (5) 1.400 2 80 311 LC1-D50// (5) 1.400 or LC1-D65// (6) 1.400 125 311 LC1-D80// 1.590 or LC1-D95// (6) 1.610 200 311 LC1-D115// 2.500 or LC1-D150// (6) 2.500 (1) 3-pole contactors for connection by lugs or bars Insert the digit 6 before the voltage code in the references selected above. Example: LC1-D09// becomes LC1-D096//. 3-pole contactors for connection by Faston connectors (1) These contactors are fitted with Faston connectors: 2 x 6.35 mm on the power poles and 1 x 6.35 mm on the coil terminals. For contactors LC1-D09 and LC1-D12 only, insert the digit 9 before the voltage code in the references selected above. Example: LC1-D09// becomes LC1-D099//. 3-pole contactors for connection by spring terminals (1) LC1-D123// 20 311 LC1-D093// (5) 0.320 or LC1-D123// (5) (6) 0.325 (7) 25/32 311 LC1-D183// (5) 0.335 Accessories Auxiliary contact blocks and modules: see pages 2/16 to 2/23. (1) 3-pole contactors LC1-D09 to D95 can be supplied without safety cover. To order, insert the digit 5 before the voltage code in the references selected above. Examples: LC1-D09// becomes LC1-D095// LC1-D096// becomes LC1-D0965// LC1-D099// becomes LC1-D0995// LC1-D093// becomes LC1-D0935// (2) See note (2) page 2/9. (3) LC1-D09 to D38 and LC1-DT20 to DT80: clip-on mounting on 35 mm � rail AM1-DP or screw fixing. " � LC1-D40 to D95 : clip-on mounting on 35 mm or 75 mm rail AM1-DL or screw fixing. � LC1 or LP1-D40 to D95 $: clip-on mounting on 75 mm rail AM1-DL or screw fixing. � LC1-D115 and D150: clip-on mounting on 2 x 35 mm rails AM1-DP or screw fixing. (4) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.160 kg for contactors LC1-D09 to D38, 0.785 kg for contactors LC1-D40 to D65 and 1 kg for contactors LC1-D80 and D95. (5) For purchase in bulk packs, see page i/7. (6) Selection according to the number of operating cycles, see AC-1 curve, page 1/10. (7) 32 A if the contactor is used with the power connection module LAD-34 or Quickfit technology outgoing terminal block LAD-33, see page 4/9. 25 A without these accessories. Selection: Characteristics: Dimensions: Schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/44 to 2/47 pages 2/48 and 2/49 Schneider Electric 2/8 810366 810367 References TeSys contactors For control in utilisation category AC-1, 20 to 200 A Control circuit: a.c., d.c. or low consumption 4-pole contactors for connection by screw clamp terminals or connectors Non inductive loads Number Instantaneous Basic reference. Weigh maximum current of poles t (θ ≤ 60 °C) auxiliary Complete with code indicating (3) utilisation category contacts control circuit voltage (2) AC-1 Fixing (1) A kg 20 4– 1 1 LC1-DT20// 1 0.365 22 1 1 LC1-D098// 1 0.365 25 4– 1 1 LC1-DT25// 1 0.365 22 1 1 LC1-D128// 1 0.365 LC1-DT20 32 4– 1 1 LC1-DT32// 1 0.425 22 1 1 LC1-D188// 1 0.425 40 4– 1 1 LC1-DT40// 1 0.425 22 1 1 LC1-D258// 1 0.425 60 4– 1 1 LC1-DT60// 1 0.425 22 1 1 LC1-D328// 1 0.425 80 4– – – LC1-D65004// 1.440 2 or LP1-D65004// 2.210 22 – – LC1-D65008// 1.450 or LP1-D65008// 2.220 125 4– – – LC1-D80004// 1.760 or LP1-D80004// 2.685 22 – – LC1-D80008// 1.840 or LP1-D80008// 2.910 200 4– – – LC1-D115004// 2.860 4-pole contactors for connection by lugs or bars Insert the digit 6 before the voltage code in the references selected above. Example: LC1-DT20// becomes LC1-DT206//. (Available 2002) 4-pole contactors for connection by spring terminals 20 4– 1 1 LC1-DT203 0.380 22 1 1 LC1-D0983 0.380 25 4– 1 1 LC1-DT253 0.380 22 1 1 LC1-D1283 0.380 32 4– 1 1 LC1-DT323 0.425 22 1 1 LC1-D1883 0.425 40 4– 1 1 LC1-DT403 0.425 22 1 1 LC1-D2583 0.425 Accessories Auxiliary contact blocks and modules: see pages 2/16 to 2/23. (1) See note (1) page 2/8. (2) Control circuit voltages. a.c. supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 500 LC1-D09...D150 and LC1-DT20...DT60 (coils with integral suppression device fitted as standard) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 – d.c. supply Volts 12 24 36 48 60 72 110 125 220 250 440 LC1-D09...D38 and LC1-DT20...DT60 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc JD BD CD ED ND SD FD GD MD UD RD LC1 or LP1-D40...D80 U 0.85…1.1 Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75…1.2 Uc JW BW CW EW – SW FW – MW – – LC1-D115 (coil with integral suppression device fitted as standard) U 0.75…1.2 Uc – BD – ED ND SD FD GD MD UD RD Low consumption Volts $ 524 48 72 LC1-D09...D38 and LC1-DT20...DT60 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc AL BL EL SL For other voltages between 5 and 690 V, see pages 2/26 to 2/31. (3) The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.165 kg and for contactors LC1-D80, 1 kg. 1 Available 4th quarter 2001. Selection: Characteristics: Dimensions: Schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/44 to 2/47 pages 2/48 and 2/49 Schneider Electric 2/9 105700_1 References TeSys contactors Reversing contactors for motor control up to 75 kW on 400 V in category AC-3, horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 3-pole reversing contactors for connection by screw clamp terminals or connectors Pre-wired power connections Mechanical interlock without electrical interlocking. Standard power ratings Rated Instantaneous Contactors supplied with coil Weight of 3-phase motors opera- auxiliary Basic reference. Complete with code (3) 50/60 Hz in category AC-3 tional contacts per indicating control circuit voltage (2) current contactor Fixing (1) in AC-3 LC2-D12// (θ ≤ 60°C) 220 V 380 V 660 V 440 V 230 V 400 V 415 V 440 V 500 V 690 V 1000 V up to kW kW kW kW kW kW kW A kg 2.2 4 4 4 5.5 5.5 – 9 11 LC2-D09// (4) 0.687 3 5.5 5.5 5.5 7.5 7.5 – 12 11 LC2-D12// (4) 0.697 47.5 9910 10 – 18 11 LC2-D18// (4) 0.707 5.5 11 11 11 15 15 – 25 11 LC2-D25// (4) 0.787 2 7.5 15 15 15 18.5 18.5 – 32 11 LC2-D32// (4) 0.797 9 18.5 18.5 18.5 18.5 18.5 – 38 11 LC2-D38// (4) 0.807 11 18.5 22 22 22 30 – 40 11 LC2-D40// 2.400 15 22 25 30 30 33 – 50 11 LC2-D50//� 2.400 18.5 30 37 37 37 37 – 65 11 LC2-D65// 2.400 22 37 45 45 55 45 – 80 11 LC2-D80// 3.200 25 45 45 45 55 45 – 95 11 LC2-D95// 3.200 LC2-D50// 30 55 59 59 75 80 75 115 11 LC2-D115// 6.350 40 75 80 80 90 100 90 150 11 LC2-D150// 6.400 3-pole reversing contactors for connection by lugs or bars For reversing contactors LC2-D09 to LC2-D38, LC2-D115 and LC2-D150, insert the digit 6 before the voltage code in the references selected above. Example: LC2-D09// becomes LC2-D096//. Accessories Auxiliary contact blocks and modules: see pages 2/16 to 2/23. (1) LC2-D09 to D38: clip-on mounting on 35 mm � rail AM1-DP or screw fixing. LC2-D40 to D95: clip-on mounting on 35 mm or 75 mm � rail AM1-DL or screw fixing. LC2-D115 and D150: clip-on mounting on 2 x 35 mm � rails AM1-DP or screw fixing. (2) Control circuit voltages. a.c. supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 500 LC2-D09...D150 (D115 and D150 coils with integral suppression device fitted as standard) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 – d.c. supply Volts 12 24 36 48 60 72 110 125 220 250 440 LC2-D09...D38 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts $ 524 48 72 LC2-D09…D38 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc AL BL EL SL For other voltages between 5 and 690 V, see pages 2/26 to 2/31. (3) The weights indicated are for reversing contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.330 kg. (4) For reversing contactors with electrical interlocking pre-wired at the factory, add suffix V to the references selected above. Example: LC2-D09P7 becomes LC2-D09P7V. Selection: Characteristics: Dimensions, schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/50 and 2/51 Schneider Electric 2/10 810369 810370 References TeSys contactors Reversing contactors for motor control up to 15 kW on 400 V in category AC-3, horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 3-pole reversing contactors for connection by spring terminals Pre-wired power connections Mechanical interlock without electrical interlocking. Standard power ratings Rated Instantaneous Contactors supplied with coil Weight of 3-phase motors opera- auxiliary Basic reference. Complete with code (3) 50/60 Hz in category AC-3 tional contacts indicating control circuit voltage (2) current per Fixing (1) in AC-3 contactor (θ ≤ 60°C) 220 V 380 V 660 V 440 V 230 V 400 V 415 V 440 V 500 V 690 V up to kW kW kW kW kW kW A kg LC2-D123// 2.2 4 4 4 5.5 5.5 9 11 LC2-D093// 0.687 3 5.5 5.5 5.5 7.5 7.5 12 11 LC2-D123//� 0.697 47.5 9910 10 18 11 LC2-D183// 0.707 5.5 11 11 11 15 15 25 11 LC2-D253// 0.787 2 7.5 15 15 15 18.5 18.5 32 11 LC2-D323// (4) 0.797 3-pole reversing contactors for connection by Faston connectors These contactors are fitted with Faston connectors: 2 x 6.35 mm on the power poles and 1 x 6.35 mm or 2 x 2.8 mm on the coil and auxiliary terminals. For reversing contactors LC2-D09 and LC2-D12 only, replace the digit 3 with a 9 in the references selected above. Example: LC2-D093// becomes LC2-D099//. Accessories Auxiliary contact blocks and modules: see pages 2/16 to 2/23. (1) LC2-D09 to D38: clip-on mounting on 35 mm � rail AM1-DP or screw fixing. (2) Control circuit voltages. a.c. supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 LC2-D09...D32 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 d.c. supply Volts 12 24 36 48 60 72 110 125 220 250 440 LC2-D09...D32 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts $ 524 48 72 LC2-D09...D32 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc AL BL EL SL For other voltages between 5 and 690 V, see pages 2/26 to 2/29. (3) The weights indicated are for reversing contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.330 kg. (4) For use with power connection module LAD-34 or Quickfit technology outgoing terminal block LAD-33 (Available 4th Quarter 2001), see page 4/9. Selection: Characteristics: Dimensions, schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/50 and 2/51 Schneider Electric 2/11 810372 References TeSys contactors Changeover contactor pairs for control in utilisation category AC-1, 20 to 200 A, horizontally mounted, pre-assembled Control circuit: a.c. or d.c. 4-pole changeover contactor pairs for connection by screw clamp terminals or connectors Pre-wired power connections LC2-DT20 to LC2-DT60 mechanical interlock without electrical interlocking. LC2-D65 and LC2-D80: Order separately 2 auxiliary contact blocks LAD-N/1 to obtain electrical interlocking between the 2 contactors (see page 2/17). For electrical interlocking incorporated in the mechanical interlock, please call our Customer information centre on 0870 608 8 608. LC2-D115 mechanical interlock with integral, pre-wired electrical interlocking. Utilisation category AC-1 Instantaneous Contactors supplied with coils Weight Non inductive loads auxiliary Basic reference. Complete with code Maximum rated contacts indicating control circuit voltage (2) LC2-DT20 operational current per Fixing (1) (θ < 60 °C) contactor A kg 20 11 LC2-DT20// 1 0.730 2 25 11 LC2-DT25// 1 0.730 32 11 LC2-DT32// 1 0.850 40 11 LC2-DT40// 1 0.850 60 11 LC2-DT60// 1 0.850 –– or LC2-D40004 (3) 2.400 80 –– LC2-D65004// 3.200 125 –– LC2-D80004// 3.200 200 –– LC2-D115004// 7.400 4-pole changeover contactor pairs for connection by lugs or bars 20 11 LC2-DT206// 1 0.730 25 11 LC2-DT256// 1 0.730 32 11 LC2-DT326// 1 0.850 40 11 LC2-DT406// 1 0.850 –– or LC2-D400046 (3) 2.400 60 –– LC2-DT606// 1 0.850 80 –– LC2-D650046// 3.200 125 –– LC2-D800046// 3.200 200 –– LC2-D1150046// 7.400 Accessories Auxiliary contact blocks and add-on modules: see pages 2/16 to 2/23. (1) LC2-DT20 to DT60: clip-on mounting on 35 mm � rail or screw fixing. LC2-D65 and D80: clip-on mounting on 35 mm or 75 mm � rail AM1-DL or screw fixing. LC2-D115: clip-on mounting on 2 x 35 mm � rails AM1-DP or screw fixing. (2) See note (2) next page. (3) For replacement in existing equipment. 1 Available 4th quarter 2001. Selection: Characteristics: Dimensions, schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/50 and 2/51 Schneider Electric 2/12 105702_1 References TeSys contactors Changeover contactor pairs for control in utilisation category AC-1, 20 and 25 A, horizontally mounted, pre-assembled Control circuit: a.c. or d.c. 4-pole changeover contactor pairs for connection by spring terminals Pre-wired power connections With mechanical interlock without electrical interlocking. Utilisation category AC-1 Instantaneous Contactors supplied with coils Weight Non inductive loads auxiliary Basic reference. Complete with code Maximum rated contacts indicating control circuit voltage (2) operational current per Fixing (1) (θ < 60 °C) contactor A kg 20 11 LC2-DT203// 0.760 25 11 LC2-DT253// 0.760 2 Accessories Auxiliary contact blocks and add-on modules: see pages 2/16 to 2/23. (1) Clip-on mounting on 35 mm � rail AM1-DP or screw fixing. (2) Control circuit voltages. a.c. supply Volts 24 42 48 110 115 220 230 240 380 400 415 440 500 LC2-DT20…DT60 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 – d.c. supply Volts 12 24 36 48 60 72 110 125 220 250 440 LC2-DT20…DT60 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts $ 5 244872 LC2-DT20...DT60 (coils with integral suppression device fitted as standard) U 0.7…1.25 Uc AL BL EL SL For other voltages between 5 and 690 V, see pages 2/26 to 2/31. Selection: Characteristics: Dimensions, schemes: pages 1/6 to 1/35 pages 2/32 to 2/37 pages 2/50 and 2/51 Schneider Electric 2/13

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the LC1-D123?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SCHNEIDER ELECTRIC GV1-A01 AUXILIARY CONTACT

product

Schneider Electric LAD6K10B Mechanical, Latch Block Contactor

product

Schneider Electric LADLVRT24V 24V Low Voltage Ride Through Module; Used On Tesys[T] Lc1d/Cad Series ...

product

Schneider Electric LADN10 Contactor Auxiliary Contact Block IEC

product

Schneider Electric LC1D0910M7 9A; 3 Pole; 220VAC Contactor

product

Schneider electric LC1-D093-A65 Contactor 9AMP 3POLE 120VAC W/ 1NO AUX