POWER-ONE MAP110
Features
- Greater than 134,000 hours MTBF
- Industry-standard footprint: 7.00" x 4.30" x 1.97" (177.8 x 109.2 x 50.0 mm)
- Input transient & ESD compliance to EN61000-4-2/-3/-4
- New 3.3 V and 5 V output models
- Options include overtemperature protection, Power Fail signal, chassis, & cover
- Remote sense and overvoltage protection on single output units and main output of multiple output units
- RoHS lead-solder-exemption compliant
- Universal input 85-264 VAC
Datasheet
Extracted Text
MAP110 AC-DC Series Data Sheet Features • RoHS lead-solder-exemption compliant New 3.3 V and 5 V output models Universal input 85-264 VAC Industry-standard footprint: 7.00" x 4.30" x 1.97" (177.8 x 109.2 x 50.0 mm) Input transient & ESD compliance to EN61000-4-2/-3/-4 Greater than 134,000 hours MTBF Remote sense and overvoltage protection on single output units and main output of multiple output units Options include overtemperature protection, Power Fail signal, chassis, & cover Description Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50V 16A 22A 0.2% 1% 1% 5.09V to 5.11V MAP110-1012 12V/15V 11.25V to 15.75V 7.5/6A (Note 2) 10/8A (Note 2) 0.1% 0.5% 1% 11.97V to 12.02V MAP110-1024 24V/28V 22.8V to 29.2V 3.8/3.2A (Note 2) 5.0/4.3A (Note 2) 0.1% 0.5% 1% 23.95V to 24.05V NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation. Multiple-Output Model Selection– 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.2% 1% 1% 11.97V to 12.03V MAP110-4000 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +24V Fixed 3A/4.5A PK 3A/4.5A PK 0.1% 1% 1% 23.94V to 24.06V MAP110-4001 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4002 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +15V Fixed 5A/7.3A PK 5A/7.3A PK 0.1% 1% 1% 14.96V to 15.04V MAP110-4003 -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.3V to -15.7V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +24V Fixed 3A/4.5A PK 3A/4.5A PK 0.1% 1% 1% 23.94V to 24.06V MAP110-4004 -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.3V to -15.7V +15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 14.3V to 15.7V Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10142 Rev. 1.0, 27-Jan-10 Page 1 of 5 www.power-one.com MAP110 AC-DC Series Data Sheet Multiple-Output Model Selection (Cont.) – 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 2% 1% 11.97V to 12.03V MAP110-4010 -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V -12V Fixed 3A/4A PK 3A/4A PK 0.3% 8% 1% -11.5V to -12.5V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4011 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +24V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 23.2V to 24.8V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4015 -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.4V to -15.6V +15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 14.4V to 15.6V +12V 11.55V to 12.45V 5A/9A PK 5A/9A PK 0.2% 0.5% 0.5% 11.96V to 12.03V +24V Fixed 4A/4.5A PK 4A/4.5A PK 0.2% 1% 1% 23.94V to 24.06V MAP110-4200 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V +5V Fixed 2A/2.5A PK 2A/2.5A PK 0.2% 1.5% 1% 4.75V to 5.25V +3.3V 3.2V to 3.4V 12A/20A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V MAP110-4300 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V (Note 3) +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +3.3V 3.2V to 3.4V 12A/15A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V MAP110-4305 -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -4.75V to -5.25V (Note 3) +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V NOTES: 1) Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak. Model numbers highlighted in yellow or shaded are not recommended for new designs. Maximum Output Rtating: MODEL/OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT OPTION BOARD ONLY BOARD ONLY ‘L’-BRACKET ‘L’-BRACKET ‘C’-COVER C’-COVER CONVECTION CONTINUOUS/PEAK 80W/110W 90W/120W 80W/110W 90W/120W 60W/110W 65W/120W FORCED AIR 200 LFM 110W 120W 110W 120W 110W 120W Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC input voltage (110 VAC) 50% load: 40 mS Full rated load: 20 Input Current 85 VAC (110W load). 3.5 ARMS 110VAC (110W load). 2.8 Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C. 41 APK Operating Frequency Switching frequency of main transformer, (fixed frequency). 20 25 kHz MCD10142 Rev. 1.0, 27-Jan-10 Page 2 of 5 www.power-one.com MAP110 AC-DC Series Data Sheet Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 230 VAC. Varies with distribution of loads among outputs. 65 75 80 % Minimum Loads Single output models. 0 Amps Multiple output models, V1 + V2 (Note 1). 1 Amps Ripple and Noise Full Load, 20 MHz Bandwidth. See Model Selection Chart. Output Power Multiple output units with convection cooling. 5 80 Watts Multiple output units with 200 LFM forced air cooling. 5 110 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 V Regulation Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing See Model Selection Chart. to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). 500 µS Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on single output models and the MAP110-1005 6.10 7.20 main output of multiple output models. MAP110-1012 17.3 20.2 MAP110-1024 32.2 37.8 V MAP110-4200 13.8 16.2 MAP110-4300 3.7 4.35 All other models. 5.75 6.75 Overload Protection Fully protected against output overload and short circuit. 150 200 % Automatic recovery upon removal of overload condition. Remote Sense Voltage drop compensated for at the load. 250 mV Input Power Fail Option, TTL compatible logic signal. Time before regulation dropout due Warning to loss of input power at 110 VAC. Active low. 3 5 mS Overtemperature Protection Option, system shutdown due to excessive internal temperature. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved. EN60950 (TUV). Dielectric Withstand Voltage Input to Output. 2600 VDC Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted & radiated. B Interference, EN55022 / CISPR 22 conducted. B Class Conducted EN55022 / CISPR 22 radiated (Note 2). A Input Transient Protection EN61000-4-5 level 3. 2 kV Insulation Resistance Input to output. 10 M� Leakage Current Per EN60950, 264 VAC. 750 µA NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. MCD10142 Rev. 1.0, 27-Jan-10 Page 3 of 5 www.power-one.com MAP110 AC-DC Series Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-operating. 50k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% per° C At 100% load: 0 50 °C to a maximum temperature of 70°C. At 50% load: 0 70 °C Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C. ±0.03 ±0.05 %/°C Relative Humidity Non-condensing. 95 %RH Options DESCRIPTION NOTES DIMENSIONS L-Bracket Add ‘L’ suffix to model number. 7.15" x 4.50" x 2.40" (182.0mm x 115.0mm x 61.0mm) Cover Add ‘C’ suffix to model number. Includes L-Bracket. 7.20" x 4.50" x 2.40" (183.0mm x 115.0mm x 61.0mm) Power Fail Add ‘P’ suffix to model number. Provides >5 mS typical warning time before N/A Signal main output drops 5%. Warning time increases at reduced load levels. Thermal Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature N/A Shutdown condition. Automatic recovery. MCD10142 Rev. 1.0, 27-Jan-10 Page 4 of 5 www.power-one.com MAP110 AC-DC Series Data Sheet OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm) OVERALL WEIGHT: 1.3 lb (0.59 kg) NOTE 1 Contact factory for dimensions for L-bracket and cover. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10142 Rev. 1.0, 27-Jan-10 Page 5 of 5 www.power-one.com
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the MAP110?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods