Description
Omron H7GP Counter/Timer Modules-DIN 48 x 24-mm Total Counter/Time Counter
Part Number
H7GP
Price
Request Quote
Manufacturer
OMRON
Lead Time
Request Quote
Category
Counter/Timer Modules
Specifications
Degree of protection
Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors).
Digits
6 digits (8.5-mm-high characters)
Dimensions
48 x 24 x 80 mm (W x H x D)
Display
7-segment, negative transmissive LCD (with red backlight)
External connections
Screw terminals
External power supply
50 mA at 12 VDC
Max. counting speeds
30 Hz or 5 kHz (selected via DIP switch)
Mounting method
Flush mounting
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max.
Rated supply voltage
100 to 240 VAC (50/60 Hz)
Features
- Compact (80 mm) body.
- Finger-protection terminal block cover prevents electrical shock and conforms to VDE0106, Part 100.
- High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and built-in red LED backlight at low power consumption.
- IP66 with oil resistance and NEMA 4 protection achieved by unifying the front with the case and by using oil-resistant parts and materials.
- Just change a switch setting for either an NPN or PNP input.
- Supports both external resetting and manual resetting.
Datasheet
Extracted Text
Total Counter/Time Counter (DIN 48 x 24) H7GP CSM_H7GP_DS_E_4_1 DIN 48 x 24-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 • High-visibility, negative transmissive LCD display with 8.5-mm- high characters and built-in red LED backlight at low power consumption. IP66 with oil resistance and NEMA 4 protection achieved by unifying the front with the case and by using oil-resistant parts and materials. Compact (80 mm) body. Just change a switch setting for either an NPN or PNP input. Supports both external resetting and manual resetting. Finger-protection terminal block cover prevents electrical shock and conforms to VDE0106, Part 100. Certified for UL and CSA safety standards. Complies with EMC standards (EN 61326) and CE Marking. Model Number Structure ■ Model Number Legend H7GP-@@@ 1 2 3 1. Classification 3. Case Color of Front Section C: Total counter None: Light gray (Munsell 5Y7/1) T: Time counter B: Black 2. Supply Voltage None: 100 to 240 VAC D: 12 to 24 VDC Ordering Information ■ List of Models Total counter Supply voltage 6-digit total counter Light gray Black 100 to 240 VAC H7GP-C H7GP-CB 12 to 24 VDC H7GP-CD H7GP-CDB Time counter Supply voltage 6-digit time counter Light gray Black 100 to 240 VAC H7GP-T H7GP-TB 12 to 24 VDC H7GP-TD H7GP-TDB 1 H7GP Specifications ■ Ratings Item 6-digit total counter 6-digit time counter H7GP-C H7GP-CD H7GP-T H7GP-TD Rated supply voltage 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) External power supply 50 mA at 12 VDC --- 50 mA at 12 VDC --- Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max. Dimensions 48 x 24 x 80 mm (W x H x D) Mounting method Flush mounting External connections Screw terminals Degree of protection Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors). Display 7-segment, negative transmissive LCD (with red backlight) Digits 6 digits (8.5-mm-high characters) Input mode Up (increment) Accumulative Max. counting speeds 30 Hz or 5 kHz (selected via DIP switch) --- Counting range 0 to 999999 --- Time specification --- 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s Timing accuracy --- ±100 ppm (–10°C to 55°C) Memory backup EEP-ROM: 200,000 operations min. Input Input signals Count, reset, and key protection (see note 2) Start, reset, and key protection (see note 2) Input method No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch) Count, reset, No-voltage input (NPN transistor input) start Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage:2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 kΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ max. Key protection No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage:0.5 VDC max. Open (OFF) impedance: 100 kΩ min. Input re- Reset 20 or 1 ms (automatically switched according to counting 20 ms sponse speed) speed Start --- 20 ms Key protection Approx. 1 s Approx. 1 s Reset system External and manual resets Note: 1. Contains 20% ripple (p-p) max. 2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional. 2 H7GP ■ Characteristics Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) Noise immunity ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals), ±480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Display: Malfunction:8 kV Destruction:15 kV DIP switch: Malfunction:4 kV Destruction:8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions 2 Shock resistance Destruction: 294 m/s each in three directions 2 Malfunction: 196 m/s each in three directions Ambient temperature Operating: –10°C to 55°C (with no icing) Storage: –25°C to 65°C (with no icing) Ambient humidity Operating: 35% to 85% EMC (EMI) EN61326 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61326 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) Approved standards UL508, CSA22.2 No.14, conforms to EN61010-1, VDE0106/P100 Case color Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) Weight Approx. 75 g 3 H7GP Connections ■ Terminal Arrangement Note: Non-contact input is also available. AC Models H7GP-C H7GP-T External power supply External power supply 12 VDC 50 mA max. 12 VDC 50 mA max. 100 to 240 VAC 100 to 240 VAC Power Power Power Power 0 V 12 VDC 0 V 12 VDC supply supply supply supply 56 7 8 56 7 8 1 2 3 4 1 2 3 4 Key protection Key protection Reset Count Reset Count Unused Unused input input input input input input NPN mode NPN mode PNP mode PNP mode DC Models H7GP-CD H7GP-TD 12 to 24 VDC 12 to 24 VDC Power Power 0 V Unused Unused 0 V Unused Unused supply supply 56 7 8 56 7 8 1 2 3 4 1 2 3 4 Key protection Reset Count Key protection Reset Start Unused Unused input input input input input input NPN mode NPN mode PNP mode PNP mode 4 H7GP Operation ■ DIP Switch Settings Set all DIP switches before mounting the Counter to a control panel. H7GP-T/-TD All switches are set toward the display panel before shipping. Switch Item Function H7GP-C/-CD 3 (On right side Input mode Display side NPN from front) (note 1) Terminal side PNP Switch Item Function 4 (On left side Time range Display side 99999.9h 3 (On right side Input mode (note Display side NPN from front) (note 1) (note 2) from front) 1) Terminal side PNP Terminal side 99 h 59 min 4 (On left side Counting speed Display side 30 Hz 59 s from front) (note 1) Terminal side 5 kHz Note: 1. When the setting has been changed, turned power off and on to continue. The display will show “0” when the power is turned back on. 2. The decimal point will flash every second when “99999.9 h” is set. ■ Operating Modes Total Counters Time Counters Reset input Reset input Count input Start input 999999 99999.9 h (see note) Display Display 0 0.0h Note: The count value will return to "0" when "999999" is Note: Display values are shown for full scale set to 99999.9 h. exceeded. The count value will return to "0" when "99999.9" is The display and output are turned OFF when the power exceeded. supply turns OFF, but the count value is stored internally. The display and output are turned OFF when the power supply turns OFF, but the count value is stored internally. Nomenclature 4 1. Reset Key Resets the count value, but will not operate while the keys are protected. 2. Key Protection Indicator Lit while the keys are protected. (Reset Key is 2 disabled.). 3 3. NPN/PNP DIP Switch (Count or start with reset) When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. See below for details. 4. Counting Speed DIP Switch (H7GP-C) 1 Time Range DIP Switch (H7GP-T) When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. Refer to DIP Switch Setting for details. 5 H7GP Dimensions Note: All units are in millimeters unless otherwise indicated. H7GP-C H7GP-T Panel Cutouts Panel cutouts are as shown below M3.5 terminal screw (according to DIN43700). 50 min. 5.0 min. +0.6 +0.6 45 45 0 0 +0.3 +0.3 22.2 22.2 0 0 Terminal cover (provided) Note: 1. The mounting panel thickness should be 1 to 6 mm. 2. Water resistance will be lost if Counters are mounted side-by-side. 3. The terminal screws are M3.5. (Theeffective thread length is 6 mm.) 4. When horizontally mounting Counters side-by-side, leave at least 50 mm With Flush Mounting Bracket between any two Counters. Y92S-32 rubber Y92F-32 flush mounting Panel packing (provided) adaptor (provided) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the H7GP?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

Omron H7CX-A114D1-N Counters/Timer Modules-48*48mm (1/16 DIN), 11-Pin Socket, 4 Digits, 1-Stage, Sup...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods