Details

Part Number H7BX
Manufacturer OMRON
Category Counter/Timer Modules
Price Request Quote
Lead Time Request Quote

Description

Omron H7BX Counter/Timer Modules-DIN 72 × 72 mm Multifunction Counter

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a H7BX? We can help you find it at a competitive price!

Specifications

Digits 6 digits
Display Backlit 7-segment negative transmissive LCD
External connections Screw terminals
External power supply 12 VDC (±10%), 100 mA
Input signals CP1, CP2, reset 1, reset 2, key protection
Max. counting speed 30 Hz or 5 kHz
Mounting method Flush mounting
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption 9.6 VA max. (100 to 240 VAC)
Power supply voltage 100 to 240 VAC (50/60 Hz),24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.)

Features

  • Complies with UL, CSA, and CE marking.
  • Degree of protection: IP54 equivalent (front section only).
  • Easy operation with a key for each digit.
  • Highly visible display with backlit transmissive LCD.
  • Perform all basic settings with a DIP switch.
  • Provides a total and preset counter, batch counter, dual counter, and tachometer.
  • Selectable display color (red/green) enables checking output status at a distance.
  • Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-wire DC sensors.

Datasheet

Download "Omron-H7BX-ds-256333063.pdf" (2563 KiB)

Extracted Text

Multifunction Counter (DIN 72 × 72) H7BX CSM_H7BX_DS_E_4_1 DIN 72 × 72 mm Multifunction Counter with a Bright, Easy-to-view, Negative Transmissive LCD. • Highly visible display with backlit transmissive LCD. Selectable display color (red/green) enables checking output status at a distance. Easy operation with a key for each digit. Perform all basic sett ings with a DIP switch. Provides a total and preset counter, batch counter, dual counter, and tachometer (See note.). Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2- wire DC sensors. Complies with UL, CSA, and CE marking. Degree of protection: IP54 equivalent (front section only). Refer to Safety Precautions on page 25. Note: The functions that can be selected depend on the model. Ordering Information List of Models External power supply Output type Supply voltage 1-stage 2-stage 100 to 240 VAC H7BX-A H7BX-AW Contact and 12 VDC NPN transistor output 24 VAC/12 to 24 VDC H7BX-AD1 H7BX-AWD1 Accessories (Order Separately) Name Model Soft Cover Y92A-72F1 Hard Cover Y92A-72 Terminal Cover * Y92A-72T * Supplied with the H7BX. 1 H7BX Specifications Ratings Item Model H7BX-A/AD1 H7BX-AW/AWD1 Type Preset counter Preset counter/tachometer 1-stage preset counter, 2-stage preset counter, total and 1-stage preset counter, total and preset counter *1 Supported configurations preset counter (*1), batch counter, dual counter, tachometer (selectable) (selectable) • 100 to 240 VAC (50/60 Hz) Power supply voltage *2 • 24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.) Ratings Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC) H7BX-A/AW: 9.6 VA max. (100 to 240 VAC) Power consumption H7BX-AD1/AWD1: 8 VA max. (24 VAC), 5.3 W max. (12 to 24 VDC) Mounting method Flush mounting External connections Screw terminals Degree of protection IP54 (front section only) Input signals CP1, CP2, reset 1, reset 2, key protection Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2 Input modes Increment, decrement, command (UP/DOWN A), individual (UP/DOWN B), quadrature (UP/DOWN C) Output modes N, F, C, R, K-1, P, Q, A, K-2, D, L N, F, C, R, K-1, P, Q, A, K-2, D, L, H Counter One-shot output time 0.01 to 99.99 s External reset (minimum reset input signal width: 1 ms or 20 ms selectable), manual reset, and automatic reset (internal Reset input according to C, R, P, and Q mode operation) Pulse measurement --- Periodic measurement (Sampling period: 200 ms) method Max. counting speed --- 30 Hz or 10 kHz (selectable) 30 Hz: 0.01 to 30.00 Hz Measuring ranges --- 10 kHz: 0.01 Hz to 10 kHz Tachometer Measuring accuracy --- ±0.1% FS ±1 digit max. (at 23 ±5°C) Output modes --- Upper and lower limits, area, upper limit, lower limit Auto-zero time --- 0.1 to 99.9 s Startup time --- 0.0 to 99.9 s Average processing --- OFF/2/4/8 times Prescaling function Yes (0.001 to 99.999) Decimal point adjustment Yes (rightmost 3 digits) Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Response speed: Approx. 1 s No-voltage NPN input (fixed) Key protection input Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open (OFF) impedance: 100 kΩ min. No-voltage NPN input or voltage PNP input (selectable) No-voltage input Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Input method Open (OFF) impedance: 100 kΩ min. (except key protection input) Voltage input High level: 4.5 to 30 VDC Low level: 0 to 2 VDC Input resistance: Approx. 4.7 kΩ External power supply 12 VDC (±10%), 100 mA (For details, refer to External Power Supply on page 26.) Contact output: 3 A at 250 VDC/30 VDC, resistive load (cosφ = 1) Minimum applied load: 10 mA at 5 VDC (Failure level: P, reference value) Control output Transistor output: 100 mA max. at 30 VDC max. Residual voltage: 1.5 VDC max. (approx. 1 V) Leakage current: 0.1 mA max. Backlit 7-segment negative transmissive LCD Character Heights Display *3 PV: 13.5 mm (red/green) SV: 9 mm (green) 6 digits 6 digits Counter: −99,999 to 999,999 (5 digits negative and 6 digits Digits −99,999 to 999,999 (5 digits negative and 6 digits positive) positive) Tachometer: 0 to 999,999 (6 digits) Memory backup EEPROM (Overwrites: 100,000 min.), Data storage: 10 years min. Ambient operating temperature −10 to 55°C (with no icing) Ambient storage temperature −25 to 65°C (with no icing) Ambient operating humidity 25 to 85°C (with no condensation) Case color Black (N1.5) Two flush-mounting adapters, terminal cover, DIP switch Accessories Two flush-mounting adapters, terminal cover setting stickers *1.The total and preset counter functions as a 1-stage preset counter and total counter. *2.Do not use an inverter output for the power supply. *3.Displayed only when the power is ON. Not displayed when the power is OFF. 2 H7BX Characteristics Electrical Life Expectancy Insulation 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed resistance non-current-carrying metal parts, and between non-continuous contacts (Reference Values) Between current-carrying metal parts and non-current-carrying metal parts: Resistive Load 2,000 VAC, 50/60 Hz for 1 min 1,000 Between power supply and input circuit: 2,000 VAC, 50/60 Hz for 1 min Dielectric (for models other than the H7BX-A@D1) 700 strength 1,000 VAC, 50/60 Hz for 1 min (H7BX-A@D1) 500 Between control output, power supply, and input circuit: 2,000 VAC, 50/60 Hz for 1 min Between non-continuous contacts: 1,000 VAC, 50/60 Hz for 1 min 300 30 VDC (cosφ=1) Between power terminals: 3.0 kV (1.0 kV for 24 VAC/12 to 24 VDC models) Impulse Between current-carrying terminal and exposed non-current-carrying metal withstand parts: voltage 4.5 kV (1.5 kV for 24 VAC/12 to 24 VDC models) 250 VAC (cosφ=1) 100 Between power terminals: ±1.5 kV Noise Between input terminals: ±600 V 70 immunity Square-wave noise by noise simulator (Pulse width: 100 ns/1 µs, 1-ns rise) 50 01 2 3 4 Static Malfunction: 8 kV Load current (A) immunity Destruction: 15 kV Inductive Load Destruction: 10 to 55 Hz, 0.75-mm single amplitude, 2 hours each in three Vibration directions 1,000 resistance Malfunction: 10 to 55 Hz, 0.50-mm single amplitude, 10 minutes each in 700 three directions 500 2 Shock Destruction: 294 m/s 3 times each in 6 directions 2 resistance Malfunction: 98 m/s 3 times each in 6 directions 300 Life Mechanical: 10,000,000 operations min. 30 VDC (L/R=7 ms) expectancy Electrical: 100,000 operations min. (3 A at 250 VAC/30 VDC, resistive load) * Weight Approx. 250 g * Check the electrical life expectancy curve. 100 250 VAC (cosφ=0.4) Applicable Standards 70 50 Approved cURus: UL 508, CSA C22.2 No. 14 01 2 3 4 safety EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II; Load current (A) standards EN 61326; VDE 0106 Part 100 A current of 0.15 A max. can be switched at (EMI) EN 61326 125 VDC (cosφ = 1) and current of 0.1 A max. Emission Enclosure: EN 55011 Group 1 class A can be switched with L/R = 7 m/s. In both Emission AC mains: EN 55011 Group 1 class A cases, a life of 100,000 operations can be (EMS) EN 61326 expected. Immunity ESD: EN 61000-4-2: 4 kV contact discharge; 8 kV air discharge Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz); 10 V/m (Pulse-modulated, EMC 900 MHz ±5MHz) Immunity Conducted Disturbance: EN 61000-4-6: 3 V (0.15 to 80 MHz) Immunity Burst: EN 61000-4-4: 2 kV power-line; 1 kV I/O signal-line Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines (relay outputs)); 2 kV line to ground (power and output lines (relay outputs)) Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage) 3 3 No. of operations (×10 ) 3 No. of operations (×10 ) H7BX I/O Functions Using as a Counter *1 Using as a Tachometer (1) All Modes Except for Dual Counter Mode Reads counting signals. CP1, • Reads count signals. (CP2 input is not CP2 • Increment, decrement, up/down (command, individual, or quadrature) inputs available.) CP1, CP2 can be used. • Holds the measurement (2) Dual Counter Mode Inputs value and outputs. • Reads CP1 count signals on CP1 input and CP2 count signals on CP2 input. Reset 1, (Reset 2 input is not • Increment signals can be used. Reset 2 available.) (1) All Modes Except for Dual Counter Mode • The reset indicator is lit Inputs • Resets present value and outputs (OUT2 when using the batch counter). *2 during hold. • Counting cannot be performed while resetting or when reset 1 input is ON. Outputs signals according Reset or • The reset indicator is lit while the reset input is ON. to the specified output Reset 1 (2) Dual Counter Mode Outputs OUT1, 2 mode when a set value is • Resets the CP1 present value to 0. reached. • Counting the CP1 input cannot be performed while the reset 1 input is ON. • The reset indicator is lit while the reset 1 input is ON. Total Reset Using as a Counter or The reset operation depends on the selected function. *3 or Reset 2 Tachometer When the corresponding set value is reached, signals are output according to the Outputs OUT1, 2 designated output mode. • Prohibits using the keys on the front panel. *1.Refer to pages 14 to 17 for information on the operation of input and output functions. • Set the key protection *2.In increment mode or increment/decrement mode, the present value returns to 0; in Key protection level in function selection mode. decrement mode, the present value returns to the set value with 1-stage models, and returns input • Key protection is enable to set value 2 with 2-stage models. by short-circuited key *3.The reset indicator will not be lit when the total reset or reset 2 input is ON. protection terminals. Function Reset operation Note: For details, refer to page 24. 1-stage/2-stage preset counter Does not operate (Not used). • Resets the total count value. Total and preset counter • Holds the total count value at 0 while the total reset input is ON. • Resets the batch count value and batch output (OUT1). Batch counter • Holds the batch count value at 0 while the reset 2 input is ON. • Resets the CP2 present value. Dual counter • Counting for CP2 input is disabled while the reset 2 input is ON. 4 H7BX Connections Terminal Arrangement Confirm that the power supply meets specifications before using the H7BX. H7BX-A H7BX-AW 0 V 0 V 8 9 10 11 12 13 14 8 9 10 11 12 13 14 (−) (+) (−) (+) External power supply External power supply Unused. Unused. 15 17 Unused. 15 17 OUT1 OUT OUT2 Key Key 16 18 16 18 protection protection OUT OUT2 OUT1 1234567 1234567 H7BX-AD1 H7BX-AWD1 0 V 0 V 8 9 10 11 12 13 14 8 9 10 11 12 13 14 (−) (+) (−) (+) External power supply External power supply Unused. Unused. 15 17 Unused. 15 17 OUT1 OUT OUT2 Key Key 16 18 16 18 protection protection OUT OUT2 OUT1 1234567 1234567 (−) (+) (−) (+) Note: Do not use the unused terminals for relay connections. Block Diagram Input Circuits CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input (Basic insulation) Power supply Output circuit circuit +14 V (Basic insulation) 1 kΩ Display circuit Internal Internal control Note: The circuit shown above is for IN Input circuit circuit circuit no-voltage input (NPN input). Key switch circuit 5 Reset 1 Reset 1 CP2 CP2 CP1 CP1 Unused. Reset 2 Unused. Reset 2 12 VDC Unused. Unused. 12 VDC Unused. Unused. Output COM Output COM Reset 1 Reset 1 CP2 CP2 CP1 CP1 Reset 2 Reset 2 Unused. 12 VDC 12 VDC Unused. Output COM Output COM H7BX Input Connections A no-voltage input (short-circuit or open) or voltage input can be selected for each input. (The key protection input is always a no-voltage input (NPN input)). No-voltage Inputs (NPN Inputs) Open Collector Voltage Output Contact Input DC Two-wire Sensor PLC Sensor or sensor 8 9 10 11 12 16 Terminal No. 8 9 10 11 12 16 Terminal No. 8 9 10 11 12 16 Terminal No. Terminal No. 8 9 10 11 12 16 Operates when the transistor turns ON. Operates when the transistor turns ON. Operates when the contact turns ON. Operates when the transistor turns ON. Note: When the H7BX is used as a tachometer, the CP2 input and total reset/reset 2 input are not used. No-voltage Input Signal Levels Applicable Two-wire Sensors Short-circuit level Transistor ON • Leakage current: 1.5 mA max. • Residual voltage: 3 V max. • Switching capacity: 5 mA min. • Impedance when ON: 1 kΩ max. • Residual voltage: 3 VDC max. No-contact (The leakage current is approx. 12 mA when the impedance is • Operating voltage: 10 VDC input 0 Ω.) Open level Transistor OFF • Impedance when OFF: 100 kΩ min. Contact input Use contact which can adequately switch 5 mA at 10 V. Note: Use a DC power supply of 30 V max. Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) No-contact Input (PNP Transistor) Contact Input Sensor Sensor Terminal No. 8 9 10 11 12 Terminal No. 8 9 10 11 12 Terminal No. 8 9 10 11 12 Operates when the contact turns ON. Operates when the transistor turns OFF. Operates when the transistor turns ON. Note: When the H7BX is used as a tachometer, the CP2 input and total reset/reset 2 input are not used. Voltage Input Signal Levels High level (Input ON): 4.5 to 30 VDC Low level (Input OFF): 0 to 2 VDC Note: 1. Use a DC power supply of 30 V max. 2. Input resistance: Approx. 4.7 kΩ 6 0-V input Reset/reset 1 input 0-V input CP2 input Reset/reset 1 input CP1 input CP2 input Total reset/reset 2 input CP1 input Key protection input Total reset/reset 2 input 0-V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input 0-V input Key protection input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input 0-V input Reset/reset 1 input CP2 input CP1 input Total reset/reset 2 input Key protection input 0-V input 0-V input Reset/reset 1 input Reset/reset 1 input CP2 input CP2 input CP1 input CP1 input Total reset/reset 2 input Total reset/reset 2 input Key protection input H7BX Nomenclature Indicators Operation Keys A A Reset Indicator (Orange) I Mode Key B D Lit when the reset input (1) or reset key is ON. Used to switch mode and setting items. C F B Key Protection Indicator (Orange) J Reset Key E G H C Control Output Indicator (Orange) 1 to 6 K Up Keys: K OUT: One stage OUT1, OUT2: Two stages J I D Present Value (Main Display) Character height: 13.5 mm (Red/green selectable) Switches E Set Value (Sub-display) Character height: 9 mm (Green) L DIP Switch F Total Count Indicator (Green) 1 2345678 Lit when the total count value is displayed. OFF G Batch Indicator (Green) L ON Lit when the batch count value is displayed. H Set Value 1 and 2 Stage Indicators (Green) Dimensions (Unit: mm) Counter Counter H7BX-A@@ M3.5 terminal screw 6 100 72 (effective length: 6 mm) 72 67.6 × 67.6 Note: M3.5 terminal screws (effective length: 6 mm). Dimensions with Flush Mounting Adapter H7BX-A@@ (The flush mounting adapter is supplied with the H7BX.) Panel Cutouts Panel cutouts are as shown below M3.5 terminal screw (according to DIN 43700). 72 (effective length: 6 mm) 100 min. +0.7 68 −0 +0.7 68−0 72 69 × 69 82 min. Panel 6 102 5 + panel thickness Note: The mounting panel thickness must be 1 to 5 mm. Accessories (Order Separately) Soft Cover Hard Cover Terminal Cover * Y92A-72F1 Y92A-72 Y92A-72T Product Protection for Use in Environments Subject to Water or Oil (VDE0106/T100) The panel surface has a protective structure so that the internal circuits will not be adversely affected if drops of water penetrate the gaps between the keys. If, however, there is a possibility of water or oil being present on the operator's hands, mount the optional Soft Cover. The Soft Cover ensures protection Note: Depending on the operating equivalent to IP54. Do not, however, use environment, the condition of resin parts the H7BX in locations where it would come may deteriorate, and may shrink or * Supplied with the H7BX. into direct contact with oil. harden. Therefore, it is recommended that resin parts are replaced regularly. 7 H7BX-A COUNTER t N MA .D E IN C HI NA Lo o X X X X X X OMRON Corporation H7BX Operating Procedures Setting Procedure Guide Settings for Counter Operation (1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter) ● Using Basic Settings Only Basic Settings 1 2345678 • Counting speed (30 Hz, 5 kHz) The settings can be made OFF • Input mode (UP, DOWN) easily with the DIP switch. • Output mode (N, F, C, K-1) For details on the setting ON • One-shot output time (0.5 s, 0.05 s) methods, refer to page 9. • Reset input signal width (20 ms, 1 ms) • NPN/PNP input mode (NPN, PNP) ● Using Input Modes Not Given Above (Up/Down A, ● Performing Advanced Settings: Dual Count Calculating Up/Down B, Up/Down C), Output Modes Mode, Output 1 Time, Decimal Point Position, Prescale (R/P/Q/A/K-2/D/L/H), or (OUT2) Output Time Value, Display Color, or Key Protect Level Settings other than the basic functions above can Set all functions with the operation keys. be performed with the operation keys. For details on the setting methods, For details on the setting methods, refer to page 10. refer to page 10. Note: The default setting is for a 1-stage preset counter. (For models with a 2-stage setting, the default is a 2-stage preset counter.) Setting for Tachometer Operation (H7BX-AW@ only) ● Using Basic Settings Only Basic Settings 1 2345678 • Counting speed (30 Hz, 10 kHz) The settings can be made OFF • Output mode (HI-LO, AREA, HI-HI, LO-LO) easily with the DIP switch. • Average processing (OFF, 2, 4, 8 times) For details on the setting ON • NPN/PNP input mode (NPN, PNP) methods, refer to page 19. ● Performing Advanced Settings: Decimal Point Position, Prescale Value, Auto-zero Time, Startup Time, Display Color, or Key Protect Level Settings other than the basic functions above can be performed with the operation keys. For details on the setting methods, refer to page 20. Note: The default setting is for a 2-stage preset counter. 8 H7BX Operating Procedures (Counter Function) Settings for Basic Operations Settings for basic functions can be performed with just the DIP switch. Be sure to turn ON pin 1 when using the DIP switch. 1 2345678 OFF ON Item OFF ON 1 DIP switch settings enable/disable Disabled Enabled Pin 4 Pin 5 Output mode 2 Counting speed 30 Hz 5 kHz OFF OFF N 3 Input mode UP (increment) DOWN (decrement) ON OFF F 4 Output mode Refer to the table on the right. OFF ON C 5 ON ON K-1 6 One-shot output time (See note.) 0.5 s 0.05 s 7 Reset input signal width 20 ms 1 ms 8 NPN/PNP input mode NPN (no-voltage) PNP (voltage) Note: All the pins are factory-set to OFF. The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 23. • Always turn OFF the power supply before changing the DIP switch settings. Caution • Always turn ON pin 1 when performing settings with the DIP switch. Performing settings with the DIP switch is disabled when pin 1 is OFF. • DIP switch setting changes will be updated when the power is turned ON. Perform the settings before performing installation and supplying power. • Properly set the DIP switch to match the item being counted (or measured) and use the DIP switch monitor for confirmation. • Use the keys on the front panel to perform all settings for input modes, output modes, and output times that cannot be set with the DIP switch. For details on the setting methods, refer to page 10. When performing these settings, always turn OFF pin 1(DIP switch setting) (disabled). Using the H7BX as a Total and Preset Counter, Batch Counter, or Dual Counter The default setting is for a 1-stage preset Power ON counter. (For models with a 2-stage setting, the default is for a 2-stage preset counter.) To make changes, use the procedure shown on the right. For details, refer to page 23. Configuration selection mode Run mode Key + K Up 1 ey for at Configuration least 1 s (See note.) selection Up 1 Hold down the Key and press the Key Select the configuration using the K Up ey. (The configurations that can be selected depend on the model.) for at least 1 s. The mode will not change if the Key is Up 1 pressed first. (1-stage preset (2-stage preset (Total and (Batch counter) (Dual counter) (Tachometer) counter) counter) preset counter) Note: This includes using a model with a 2-stage setting as a 1-stage preset counter. After setting the DIP switch for basic operations, advanced functions (*) can be added using the operation keys. For details, refer to page 10. * Advanced functions consist of dual count calculating mode, output 1 time, decimal point position, prescale value, display color, and key protect level. 9 Convenient Function H7BX-A COUNTER t MADE IN CHINA Lo No. X X X X X X OMRON Corporation H7BX When using the H7BX as a Total and Preset Counter, Batch Counter, or Dual Counter, switch the configuration using the procedure on page 23. Setting Advanced Functions Settings that cannot be performed with the DIP switch are performed with the operation keys. Power ON For details on operations and display in run mode, refer to page 12. The display depends on the configuration used. *1. If the mode is switched to the function setting mode during operation, operation will continue. *2. Changes made to settings in function setting mode are enabled for the first time when the mode is *1 *2 changed to run mode. Also, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. 3 s min. 3 s min. The characters displayed in reverse video are the default settings. When performing settings with operation keys only, turn OFF pin 1 of the DIP switch (factory setting). If pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed. *3 *3. When using as a dual counter Dual count Up • Set the input mode with any of the Keys. calculating mode Input mode (ADD) (CNTM) *5 *5 • Set the dual count calculating mode (UP) (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C) the Key. Up *5. Displayed for output modes other than K-2, D, L, and H only. *4 • Set the output mode with any of the Keys. Up (Addition)(Subtraction) Output mode *4. Displayed only when the (OUTM) *6 *6 *6 *6 output mode is K-2, D, L, or H. (N) (F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H) *6. The input mode is displayed only when increment/decrement is selected. (H is only for models with 2-level setting.) *7 Up *7. Set the number for each digit with the Keys. • Set the number for each digit with the K Up eys. Output time ● 2-stage Preset Counter (OTIM) Output 2 time (0.01 s) (0.50 s) (99.99 s) (0.01 s) (0.50 s) (99.99 s) (OTM2) Note: Displayed only when the Note: Displayed only when the output mode is C, R, K-1, P, output mode is C, R, K-1, Q, A, or K-2. P, Q, A, or K-2. Counting • Set the counting speed with any of the Keys. Up speed Output 1 time (CNTS) (Outputs held) (0.01 s) (99.99 s) (OTM1) If the output time is 0.00, (30 Hz) (5 kHz) hold is displayed. Note 1: Displayed for output modes other than D, L, and H. Min. reset • Set the min. reset input signal width with any of the Keys. Up Note 2: HOLD cannot be set period when the output mode (IFLT) is K-2. ● Batch Counter (20 ms) (1 ms) Output 2 time (0.01 s)(0.50 s)(99.99 s) (OTM2) Note: Displayed only when the Decimal point • Set the decimal point position with any of the Keys. Up output mode is C, R, position K-1, P, Q, A, or K-2. (DP) No decimal One digit after Two digits after Three digits after point decimal point decimal point decimal point Prescale • Set the number for each digit with the K Up eys. value (PSCL) (0.001) (1.000) (99.999) NPN/PNP • Set the NPN/PNP input mode with any of the Keys. Up input mode (IMOD) (NPN (PNP input) input) Display • Set the display color with any of the Keys. Up color (COLR) (Red) (Green) (Red- (Green- green) red) Key • Set the key protect level with any of the Keys. Up protection level (KYPT) (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) 10 Function setting mode Run mode H7BX Explanation of Functions Settings marked with a star can be performed with the DIP switch. • Input Mode (cntm) ★ • Reset Input Signal Width (iflt) ★ Set increment mode (UP), decrement mode (DOWN), or one of the Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/ reset/reset 2 inputs together. If contacts are used for input signals, set DOWN C) as the input mode. Input modes other than UP or DOWN the counting speed to 20 ms. Processing to eliminate chattering is modes cannot be set using the DIP switch. Use the operation keys if performed for this setting. other modes are required. (For details on the operation of the input • Decimal Point Position (dp) modes, refer to Input Modes and Present Value on page 13.) Decide the decimal point position for the present value, CP1/CP2 • Dual Count Calculating Mode (calm) present values, set values (SV1, SV2), total count value, dual count When the H7BX using as a dual counter, select either ADD (addition) value and dual count set value. or SUB (subtraction) as the calculation method for the dual count • Prescale Value (pscl) value. ADD: Dual count value = CP1 PV + CP2 PV Pulses input to the counter are converted according to the specified SUB: Dual count value = CP1 PV − CP2 PV prescale value. Setting range: 0.001 to 99.999 • Output Mode (outm) ★ Example: To display the feed distance for systems that output Set the way that control output for the present value is output. The 25 pulses for a feed length of 0.5 m in the form @@.@@ m: possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. Output 1. Set the decimal point position to 2 decimal places. modes other than N, F, C, or K-1 cannot be set using the DIP switch. 2. Set the prescale value to 0.02 (0.5 ÷ 25). Use the operation keys if other modes are required. The output modes that can be set vary with the model. (For details on the 0.5 m operation of the output modes, refer to Input/Output Mode Settings on page 14.) • One-shot Output Time (otim) ★ Set the one-shot output time (0.01 to 99.99 s) for the control output. A one-shot output can be used only when C, R, K-1, P, Q, A, or K-2 25 pulses is selected as the output mode. Output times other than 0.5 s or 0.05 s cannot be set with the DIP switch. Use the operation keys if other Encoder settings are required. • One-shot Output 2 Time (otm2) ★ Note: Incorrectly setting the prescale value will result in counting When the H7BX using as a 2-stage counter or batch counter, set the errors. Check that the setting has been performed correctly one-shot output time (0.01 to 99.99 s) for control output (OUT2). A before using the H7BX. one-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is selected as the output mode. Output times other than 0.5 s or 0.05 s • NPN/PNP Input Mode (imod) cannot be set with the DIP switch. Use the operation keys if other Select either NPN input (no-voltage input) or PNP input (voltage settings are required. input) as the input format. For 2-wire sensors, set the format to NPN • One-shot Output 1 Time (otm1) input. The same format setting applies to all external inputs. For information on input connections, refer to page 6. When the H7BX using as a 2-stage counter, set the one-shot output time (0.01 to 99.99 s) for control output (OUT1). A one-shot output • Display Color (colr) can be used only when D, L, or H is selected as the output mode. If Set the color used for the present value. the output time is set to 0.00, hold is displayed, and outputs are held. Output OFF * Output ON * • Counting Speed (cnts) ★ red Red (fixed) Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2 grn Green (fixed) inputs together. If contacts are used for input signals, set the counting speed to 30 Hz. Processing to eliminate chattering is performed for r-g Red Green this setting. g-r Green Red * When the H7BX using as a 2-stage counter, this is the status of output 2. • Key Protect Level (kypt) Set the key protect level. For details, refer to Key Protect Level on page 24. 11 H7BX Operation in Run Mode • Set the number for each digit with the Keys. Up ● 1-stage Counter • Present Value Present value Shows the present count value. Set value • Set Value (Set Value 1, Set Value 2) Set the set value. ● 2-stage Counter When the present value reaches the set value, signals are output according to the specified output mode. Present value Set value 1 Present value Set value 2 ● Total and Preset Counter Present value • Present Value/Set Value Same as 1-stage counter. Set value • Total Count Value Shows the present total count value. Total count value ● Batch Counter Present value • Present Value/Set Value Same as 1-stage counter. Set value • Batch Count Value Shows the number of times the count has been completed for the present value. Batch count value • Batch Count Set Value Set the batch count set value. When the Batch count set value batch count value reaches the batch count set value, batch output (OUT1) turns ON. ● Dual Counter • Dual Count Value Dual count value Shows the sum of the CP1 present value and CP2 present value when the dual count Dual count set calculating mode is ADD and shows the value obtained by subtracting the CP2 present value value from the CP1 present value when the dual count calculating mode is SUB. • Dual Count Set Value Set the dual count set value. When the dual count value reaches the dual count CP1 present value set value, signals are output according to the specified output mode. CP2 present value • CP1/CP2 Present Value Show the present count values for CP1 and CP2 present values respectively. 12 H7BX (See note 1.) Input Modes and Present Value UP (Increment) Mode DOWN (Decrement) Mode CP1: Count input; CP2: Prohibit input CP1: Count input; CP2: Prohibit input H H CP1 CP1 L L A A A A Prohibit Prohibit H H CP2 CP2 L L n 5 n−1 4 n−2 Present Present 3 n−3 value value 2 n−4 1 n−5 0 0 0 A must be greater than the minimum signal width. (See note 2.) A must be greater than the minimum signal width. (See note 2.) CP1: Prohibit input; CP2: Count input CP1: Prohibit input; CP2: Present value H H *CP1 CP1 L L (See note 3.) A A (See note 3.) A A Prohibit Prohibit H H CP2 CP2 L L n 5 n−1 4 n−2 Present 3 Present n−3 value value 2 n−4 1 n−5 0 0 0 A must be greater than the minimum signal width. (See note 2.) A must be greater than the minimum signal width. (See note 2.) * If CP1 turns ON after the power is turned ON, it will be counted. UP/DOWN A: Command Input Mode UP/DOWN B: Individual Input Mode H H CP1 CP1 L L A A H H CP2 CP2 L L 3 3 3 3 Present Present 2 2 2 2 value 2 2 value 1 1 1 11 0 0 0 0 A must be greater than the minimum signal width. (See note 2.) UP/DOWN C: Quadrature Input Mode Note: 1. If the configuration is set to dual counter, CP1 and CP2 inputs will operate in the same way as the count input (CP1) of UP (increment) H mode. CP1 2. must be greater than the minimum signal width and B must be at A L least 1/2 the minimum signal width. If they are less, a count error of ±1 B B B B H may occur. CP2 Minimum signal width: 16.7 ms (when maximum counting speed = 30 L Hz) 100 µs (when maximum counting speed = 5 kHz) 3 3 3. The meaning of the H and L symbols in the tables is explained below. Present 2 2 2 value Input method No-voltage input Voltage input 1 1 Symbol (NPN input) (PNP input) 0 0 H Short-circuit 4.5 to 30 VDC L Open 0 to 2 VDC B must be at least 1/2 the minimum signal width. (See note 2.) 13 H7BX Input/Output Mode Settings One-shot output from OUT1 (The one-shot output time Operation for 1-stage models is the same as that for OUT2. can be set in the range 0.01 to 99.99s.) When using a 2-stage model as a 1-stage counter, total and preset counter, Self-holding Self-holding One-shot output or dual counter, OUT1 and OUT2 turn ON and OFF simultaneously. output output from OUT2 Input mode Operation after count completion UP DOWN UP/DOWN A, B, C Reset/ reset 1 999999 Set value 2 The outputs and present Set value display are held value 1 N until reset/reset 1 input 0 turns ON. OUT1 OUT2 Reset/ reset 1 999999 Set The present value value 2 display continues to Set increase/decrease. The value 1 F 0 outputs are held until reset/reset 1 input turns ON. OUT1 OUT2 As soon as the count Reset/ reaches SV, the present reset 1 value display returns to the 999999 reset start status. Set The present value display value 2 does not show the present Set value upon count-up. Output value 1 C The outputs repeat mode 0 one-shot operation. setting OUT1 self-holding output OUT1 turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output OUT2 time is independent of OUT2. Reset/ The present value display reset 1 returns to the reset start 999999 status after the one-shot Set output time. value 2 The outputs repeat one- Set shot operation. value 1 R 0 OUT1 self-holding output turns OFF after the OUT2 one-shot output time. OUT1 The OUT1 one-shot output time is independent of OUT2. OUT2 Reset/ reset 1 The present value 999999 display continues to Set increase/decrease. value 2 OUT1 self-holding Set output turns OFF after value 1 K-1 0 the OUT2 one-shot output time. The OUT1 one-shot OUT1 output time is independent of OUT2. OUT2 14 H7BX One-shot output from OUT1 (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding Self-holding One-shot output output output from OUT2 Input mode Operation after count completion UP DOWN UP/DOWN A, B, C The present value display Reset/ does not change during the reset 1 one-shot output time period, but the actual count 999999 returns to the reset start Set value 2 status. Set The outputs return to the value 1 P one-shot start state and 0 repeat one-shot operation. OUT1 self-holding output turns OFF after the OUT2 OUT1 one-shot output time. The OUT1 one-shot output OUT2 time is independent of OUT2. The present value Reset/ continues to increase/ reset 1 decrease for the one-shot 999999 output time, but returns to Set the reset start status after value 2 the one-shot output time Output Set has elapsed. value 1 mode Q 0 The outputs repeat one- setting shot operation. OUT1 self-holding output OUT1 turns OFF after the OUT2 one-shot output time. The OUT1 one-shot output OUT2 time is independent of OUT2. Reset/ reset 1 999999 Set The present value display value 2 and OUT1 self-holding Set value 1 output is held until reset/ A 0 reset 1 input turns ON. OUT1 and OUT2 are independent. OUT1 OUT2 Note: 1. When the present value reaches 999999, it returns to 0. 2. Counting cannot be performed while the reset/reset 1 input is ON. 3. If reset/reset 1 input turns ON while the one-shot output is ON, one-shot output turns OFF. 4. If there is power failure while an output is ON, the output will turn ON again when the power supply has recovered. For a one-shot output, the output will turn ON again for the duration of the output time setting once the power supply has recovered. 5. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON. 6. The set values are between 0 and 999999. 15 H7BX (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding Instanta- One-shot output neous output (equals) output Input mode Operation after count completion UP/DOWN A, B, C Reset/reset 1 999999 Set value 2 Set value 1 The display continues to increase/ decrease until the overflow or 0 K-2 underflow value is reached. −99999 Only a one-shot output is possible. OUT1 OUT2 Reset/reset 1 999999 Set value 2 The display continues to increase/ Set value 1 decrease until the overflow or 0 D underflow value is reached. The outputs are ON while the count is −99999 equal. OUT1 OUT2 Output mode setting Reset/reset 1 999999 Set value 2 The display continues to increase/ decrease until the overflow or Set value 1 underflow value is reached. 0 L OUT1 is held while the present value is less than or equal to set value 1. −99999 OUT2 is held while the present value is greater than or equal to set value 2. OUT1 OUT2 Reset/reset 1 999999 The display continues to increase/ Set value 2 decrease until the overflow or underflow value is reached. Set value 1 OUT1 is held while the present value 0 is greater than or equal to set value 1. H OUT2 is held while the present value −99999 is greater than or equal to set value 2. Note: H mode is available only when OUT1 using a 2- stage counter. OUT2 Note: 1. Counting cannot be performed while the reset/reset 1 input is ON. 2. If reset/reset 1 input turns ON while the one-shot output is ON, the one-shot output turns OFF. 3. If there is power failure while the output is ON, the output will turn ON again when the power supply has recovered. For a one-shot output, the output will turn ON again for the duration of the output time setting once the power supply has recovered. 4. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON. 5. The set values are between −99999 and 999999. 16 H7BX Total and Preset Counter Operation The H7BX has a total counter separate from the 1-stage preset counter for counting the total accumulated value. • The total counter continues to count the total accumulated value when the present value is Reset/reset 1 reset using reset/reset 1 input (Reset Key). • The total count value is reset when the total Total reset/reset 2 reset/reset 2 input is turned ON. Present value If the Reset Key is pressed while the total 0 count value is displayed, the total count value is reset. The present value is also 999999 reset at this time. Total count value • The counting range of the total counter is −99,999 to 999,999. The total count value 0 returns to 0 when it reaches the full scale limit. Batch Counter Operation The H7BX has a batch counter separate from the 1-stage preset counter for counting the number of times the count has been completed. Reset 1 Reset 2 (batch • The batch counter continues after count counter reset) completion. Set value • Batch output is held until batch counter reset Present value input turns ON. 0 • When the batch counter reset input is turned ON, the batch count value is reset, and OUT2 batch output turns OFF. Batch count set value • If the Reset Key is pressed while the batch (Sub-display) count value is displayed, the batch count 2 Batch count value 1 value is reset and batch output turns OFF. (Main display) 0 The present value is also reset at this time. OUT1 (batch output) Note: The above is for when the output mode is C. Note: 1. The batch count value is held at 0 while the batch counter reset input is on. 2. If the batch count set value is 0, batch count will be performed but there will be no batch output. 3. The batch count value returns to 0 when it reaches 999,999. 4. Once batch input has been turned ON, it will return to the ON state after power interruptions. 5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON. 6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value. Dual Counter Operation Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for which output turns ON when the set value matches the added or subtracted result. (1) Dual Count Calculating Mode = ADD (2) Dual Count Calculating Mode = SUB Dual count value = CP1 PV + CP2 PV Dual count value = CP1 PV - CP2 PV Reset 1 Reset 1 (CP1 reset) (CP1 reset) • The operation after count completion for the dual counter value is determined by the Reset 2 Reset 2 (CP2 reset) (CP2 reset) output mode. Dual count set value • The CP1 present value is reset when reset Dual count set value 1 input is turned ON and the CP2 present Dual count value Dual count value 0 value is reset when reset 2 input is turned ON. 0 CP1 present value • If the Reset Key is pressed while the dual CP1 present value count value, CP1 present value, or CP2 0 present value is displayed, all of the present 0 CP2 present value CP2 present value values are reset and the outputs turn OFF. 0 0 At this time, counting is not possible for CP1 or CP2 inputs. OUT1, 2 OUT1, 2 Note: The above is for when the output mode is N. Note: The above is for when the output mode is K-2. SUB mode can be used only when K-2, D, L, or H is selected as the output mode with 6-digit models. Note: 1. Counting is not possible for CP1 while the reset 1 input is ON. CP2 is not affected. The dual count value will be calculated based on a CP1 present value of 0. 2. Counting is not possible for CP2 while the reset 2 input is ON. CP1 is not affected. The dual count value will be calculated based on a CP2 present value of 0. 3. The counting range for the dual count value is −99,999 to 999,999. The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999. If a present value exceeds 999,999, FFFFFF will be displayed to indicate an overflow, and all counting will stop. 17 H7BX Reset Function List 1-stage/2-stage Function Total and preset counter Batch counter Dual counter counter Batch count Dual count CP1 present Display in run Present value/ Present value/ Total count Present value/ value/batch value/dual value/CP2 mode set value (1, 2) set value value set value count set count set present value value value Present value Reset/reset 1 Present value and output reset. Present value and output reset. Only the CP1 present value is reset. and output reset. Total reset/ Batch count value and batch No effect. Only the total count value is reset. Only the CP2 present value is reset. reset 2 output reset. Present value, Present value, Present value Present value batch count CP1 present value, CP2 present Present value total count Reset Key and output and output value, output value, dual count value, and and output reset. value, and reset. reset. and batch output reset. output reset. output reset. 18 H7BX Operating Procedures (Tachometer Function) (H7BX-AW@ only) Switching from Counter to Tachometer The H7BX is factory-set to the 2-stage counter configuration. To switch to the tachometer Power ON configuration, use the procedure shown on the right. For details, refer to page 23. Configuration selection mode Run mode * Hold down the Key and then press Configuration Key + K Up 1 ey for at selection least 1 s * Up 1 the Key for at least 1 s. Up 1 The mode will not change if the Switch from 2cnt to taco (tachometer) with the Key. Up Key is pressed first. Settings for Basic Operations Settings for basic functions can be performed with just the DIP switch. Be sure to turn ON pin 1. 1 2345678 OFF ON Pin 3 Pin 4 Tachometer output mode Item OFF ON OFF OFF Upper and lower limit 1 DIP switch settings enable/disable Disabled Enabled ON OFF Area 2 Counting speed 30 Hz 10 kHz OFF ON Upper limit 3 Tachometer output mode Refer to the table on the right. ON ON Lower limit 4 5 Average processing Refer to the table on the right. 6 Pin 4 Pin 5 Average processing 7 --- --- --- OFF OFF OFF (no average processing) 8 NPN/PNP input mode NPN PNP ON OFF 2 times OFF ON 4 times Note: All pins are factory-set to OFF. ON ON 8 times The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 23. • Always turn OFF the power supply before changing the DIP switch settings. Caution • Always turn ON pin 1 when performing settings with the DIP switch. Performing settings with the DIP switch is disabled when pin 1 is OFF. • DIP switch setting changes will be updated when the power is turned ON. Perform the settings before performing installation and supplying power. • Properly set the DIP switch to match the item being counted (or measured) and use the DIP switch monitor for confirmation. After setting the DIP switch for basic operations, advanced functions (*) can be added using the operation keys. For details, refer to page 20. * Advanced functions consist of the decimal point position, prescale value, auto-zero time, startup time, display color, and key protect level. 19 Convenient function H7BX-A COUNTER t X MADE IN CHINA Lo No. X X X X X OMRON Corporation H7BX When the H7BX using as a tachometer, switch to the tachometer configuration using the procedure given on page 23. Settings for Advanced Functions Settings that cannot be performed with the DIP switch are performed with the operation keys. Power ON For details on operations in run mode, refer to page 22. *1. If the mode is switched to the function setting mode during operation, operation will continue. *1 *2 *2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is automatically 3 s min. 3 s min. reset (measured values initialized and outputs turned OFF) on returning to run mode. The characters displayed in reverse video are the initial values. When performing settings with operation keys only, turn ON pin 1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed. Tachometer Up • Set the tachometer output mode with any of the Keys. output mode (TOTM) (HI-LO) (AREA) (HI-HI) (LO-LO) Counting Up • Set the counting speed with any of the Keys. speed (CNTS) (30 Hz) (10 kHz) Decimal Up • Set the decimal point position with any of the Keys. point position (DP) (No decimal (One digit (Two digits (Three digits point) after decimal after decimal after decimal point) point) point) Prescale • Set the number for each digit with the K Up eys. value (PSCL) (0.001) (1.000) (99.999) Average • Set the average processing with any of the K Up eys. processing (AVG) (No average (Average (Average (Average processing) of 2 of 4 of 8 measurements) measurements) measurements) Auto-zero • Set the number for each digit with the K Up eys. time (AUTZ) (0.1 s) (99.9 s) Startup • Set the number for each digit with the K Up eys. time (STMR) (0.0 s) (99.9 s) NPN/PNP • Set the NPN/PNP input mode with any of the K Up eys. input mode (IMOD) (NPN (PNP input) input) Display • Set the display color with any of the K Up eys. color (COLR) (Red) (Green) (Red-green) (Green-red) Key protect • Set the key protect level with any of the K Up eys. level (KYPT) (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) 20 Function setting mode Run mode H7BX Explanation of Functions Settings marked with a star can be performed with the DIP switch. • Tachometer Output Mode (totm) ★ • Auto-zero Time (avt) ★ Set the output method for control output based on the OUT1/OUT2 It is possible to set the H7BX so that if there is no pulse for a certain set value. Upper and lower limit (HI-LO), area (AREA), upper limit time the display is force-set to 0. This time is called the auto-zero time. (HI-HI), and lower limit (LO-LO) can be set. Set the auto-zero time to a time slightly longer than the estimated (For details on the operation of the output modes, refer to Output interval between input pulses. It will not be possible to make accurate Mode Settings on page 22.) measurements if the auto-zero time is set to a time shorter than the input pulse cycle. Setting a time that is too long may also result in • Counting Speed (cnts) ★ problems, such as a time-lag between rotation stopping and the alarm Set the maximum counting speed (30 Hz/10 kHz) for CP1 input. turning ON. If contacts are used for input signals, set the counting speed to 30 Hz. • Startup Time (stmr) Processing to eliminate chattering is performed for this setting. In order to prevent undesired output resulting from unstable input • Decimal Point Position (dp) immediately after the power supply is turned ON, it is possible to Decide the decimal point position for the measurement value, OUT1 prohibit measurement for a set time. This time is called the startup set value, and OUT2 set value. time. It can also be used to stop measurement and disable output until the • Prescale Value (pscl) rotating body reaches the normal rate of rotation, after the power It is possible to display the rate of rotation or the speed of a device or supply to the H7BX and rotating body are turned ON at the same time. machine to which the H7BX is mounted by converting input pulses to Display Startup time a desired unit. If this prescaling function is not used, the input frequency (Hz) will be displayed. Comparison The relationship between display and input is determined by the value (lower limit) following equation. Set the prescale value according to the unit to be displayed. Time Displayed value = f × α f: Input pulse frequency (number of pulses in 1 second) Power supply α: Prescale value Output (lower limit) 1. Displaying the Rotation Rate • NPN/PNP Input Mode (imod) ★ Display unit Prescale value (α) Select either NPN input (no-voltage input) or PNP input (voltage input) rpm 1/N × 60 as the input format. Select an NPN input when using a 2-wire sensor. rps 1/N The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page 6. N: Number of pulses per revolution • Display Color (colr) Example: In order to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@.@ rpm: Set the color used for the measurement value. 1. Set the decimal point position to 1 decimal place. Control output OFF Control output ON 2. Using the formula, set the prescale value to 1/N × 60 = red Red (fixed) 60/5 = 12. grn Green (fixed) 2. Displaying the Speed Measured value Measured value displayed in Display unit Prescale value (α) r-g displayed in red when green when either control m/min πd × 1/N × 60 *1 both control outputs 1 output 1 or control output 2 is and 2 are OFF. ON. m/s πd × 1/N Measured value Measured value displayed in N: Number of pulses per revolution g-r displayed in green when red when either control d: Diameter of rotating body (m) *2 both control outputs 1 output 1 or control output 2 is d: Diameter πd: Circumference (m) and 2 are OFF. ON. of rotating body *1.If the tachometer output mode is set to AREA, however, the measured value is displayed in red when control output 1 is OFF Note: Incorrectly setting the prescale value will result in and in green when control output 1 is ON. counting errors. Check that the setting has been *2.If the tachometer output mode is set to AREA, however, the measured value is displayed in green when control output 1 is OFF performed correctly before using the H7BX. and in red when control output 1 is ON. • Average Processing (aug) ★ • Key Protect Level (kypt) Flickering display and output chattering can be prevented by using Set the key protect level. average processing (simple averaging). Average processing can be For details, refer to Key Protect Level on page 24. set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, or 8 times. The measurement cycle will be equal to the sampling cycle (200 ms) multiplied by the average processing setting (i.e., the number of times). Average processing enables fluctuating input signals to be displayed stably. Set the optimum number of times for the application. 21 H7BX Operation in Run Mode Up • Set the number for each digit with the Keys. Measurement value • Measurement Value Displays the currently measured value. • OUT1/OUT2 Set Value Set OUT1 set value and OUT2 set value. The Measurement value measurement value is compared to OUT1 set value OUT1 set value and OUT2 set value and output is made according to the selected output mode. Measurement value OUT2 set value Output Mode Settings (Upper-limit) OUT2 set value Measurement value Upper and (Lower-limit) ON condition for OUT1: Measurement value ≤ OUT1 set value OUT1 set value lower limit ON condition for OUT2: Measurement value ≥ OUT2 set value (HI-LO) OUT1 OUT2 OUT1 set value ≤ OUT2 OUT1 set value > OUT2 OUT2 set value Condition set value set value Measurement value OUT1 set value ≤ OUT2 set value ≤ ON condition Measurement value ≤ Measurement value ≤ OUT1 set value for OUT1 Area OUT2 set value OUT1 set value (AREA) Measurement value < Measurement value < OUT1 ON condition OUT1 set value or OUT2 set value or for OUT2 Measurement value > Measurement value > OUT2 set value OUT1 set value OUT2 Output mode setting (Upper-limit) OUT2 set value Measurement value Upper (Upper-limit) ON condition for OUT1: Measurement value ≥ OUT1 set value OUT1 set value limit ON condition for OUT2: Measurement value ≥ OUT2 set value (HI-HI) OUT1 OUT2 (Lower-limit) OUT2 set value Measurement value Lower (Lower-limit) ON condition for OUT1: Measurement value ≤ OUT1 set value OUT1 set value limit ON condition for OUT2: Measurement value ≤ OUT2 set value (LO-LO) OUT1 OUT2 22 H7BX Switching between Using a Preset Counter, Total and Preset Counter, Batch Counter, Dual Counter, and Tachometer Select which H7BX configuration to use (i.e., preset counter, total and preset counter, batch counter, dual counter, or tachometer) in the configuration selection mode. The H7BX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. Power ON Up 1 Key Key Caution To change the mode to configuration selection mode, press *2 Up 1 *1 the Key for 1 s min. with the key held down. Up 1 1 s min. Up 1 The mode will not change if the Key is pressed first. Select the configuration with any of the Keys. Up Configuration selection (1-stage counter) (2-stage counter) (Total and preset (Batch counter) (Dual counter) (Tachometer) counter) Note: 1. The configuration that can be selected depend on the model. 2. The default setting is for a 1-stage preset counter. (For models with a 2-stage setting, the default is for a 2-stage preset counter.) Up The status of the DIP switch pins (1 to 8) can be confirmed using the Keys. DIP switch Note: This display is possible only if DIP switch pin 1 (DIP switch settings) is set to ON monitor (i.e., enabled). (DIP) Example 1 2345678 OFF ON ···Indicates that DIP switch pin 8 is ON. ···Indicates that DIP switch pin 7 is OFF. ···Indicates that DIP switch pin 6 is ON. ···Indicates that DIP switch pin 5 is OFF. ···Indicates that DIP switch pin 4 is ON. ···Indicates that DIP switch pin 3 is OFF. ···Indicates that DIP switch pin 2 is ON. ···Indicates that DIP switch pin 1 is ON. *1. When the mode is changed to configuration selection mode, the present value is reset, outputs turns OFF, and counting (measuring) stops. *2. Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is changed, the set value (or set value 1 and set value 2), OUT1 set value or OUT2 set value are initialized. 23 Convenient function Run Mode Configuration Selection Mode H7BX Key Protect Level When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key protect switch after the H7BX is mounted to the panel. Key protection is enable by short-circuited key protection terminals. Key protect indicator Details Up/Down Keys Level Meaning Changing mode Switching display Reset Key (Up Keys for 6-digit (See note.) in run mode models) KP-1 No Yes Yes Yes (default setting) KP-2 No Yes No Yes KP-3 No Yes Yes No KP-4 No Yes No No KP-5 No No No No Note: Changing to configuration selection mode and function selection mode. Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display Error Output status Correction method Set value after reset Either press the Reset Present value ----- No change No change Key or turn ON reset No change underflow *2 *1 input. Either press the Reset Present value fffff No change No change Key or turn ON reset No change overflow *3 *1 input. *4 Either press the Reset e1 Not lit CPU OFF Key or reset the power No change supply. Reset the power e2 Not lit Memory error (RAM) OFF No change supply. Reset to the factory Memory error (EEP) e2 sum OFF settings using the 0 *5 Reset Key. *1.Display flashes (1-second cycles). *2.Occurs when the present value or the total count value goes below −99,999 *3.Occurs when the present value reaches 999,999 under the following conditions: • The output mode is K-2, D, L, or H. • The H7BX is set for dual counter operation. *4.Except when the H7BX is used as a tachometer. *5.Includes the case where the EEPROM has reached its overwrite lifetime. 24 H7BX-A COUNTER . MADE IN CHINA Lot No X X X X X X i OMRON Corporat on H7BX Safety Precautions Refer to Safety Precautions for All Counters. • Use a commercial power supply as the AC power supply for the Caution H7BX. Using an inverter output with an output frequency of 50/60 Hz as the power supply may cause the H7BX to produce smoke or Minor injury due to electric shock may occasionally become damaged by burning. occur. Do not touch any of the terminals while power is • Use a switch, relay, or other device with contacts so that the rated being supplied. power supply voltage will be reached within 2 s. If the power supply voltage is not reached quickly enough, the outputs may Fire may occasionally occur. Tighten the terminal malfunction. screws to a torque of 0.5 to 0.6 N·m (4.4 to 5.3 in-lb). • Use a switch, relay, or other device with contacts so that the rated power supply voltage will be reached within 2 s. If the power supply voltage is not reached quickly enough, the outputs may malfunction. Minor injury due to explosion may occasionally occur. Do not use the H7BX where subject to flammable or Installation and Wiring explosive gas. • To mount the H7BX to a panel, attach the two supplied adapters to the left and right sides of the H7BX, and securely tighten the If the output relay is used beyond its life expectancy, its knurled screws on the adapters by hand, maintaining a balance contacts may become fused or there may be a risk of between them. Damage may result if the knurled screws are fire. excessively tightened with pliers or other tools. Use the output relay within its rated load and electrical • Be sure to wire the terminals correctly. life expectancy. The life expectancy of the output relay • Up to two wires of the same size and type can be inserted into a varies considerably according to its usage. single terminal. • Do not connect more than two crimp terminals to each H7BX terminal. Minor electric shock, fire, or malfunction may • Use the specified wires for wiring. occasionally occur. Never attempt to disassemble, Applicable wire: AWG 24 to AWG 18 (equal to a cross-sectional modify, or repair the H7BX or touch any of the internal 2 area of 0.20 to 0.82 mm ) parts. Solid wire or twisted wire (copper), operating temperature over 70°C. • Separate the H7BX, the devices that generate input signals, and Precautions for Safe Use input signal wires from any potential sources of noise, such as high-voltage lines. Operating Environment Handling • The H7BX is intended for indoor use only. Do not use the H7BX • Do not use organic solvents (such as paint thinner or benzine), outdoors or in any of the following locations. strong alkaline, or strong acids because they will damage the • Locations subject to sudden or extreme changes in temperature. external finish. • Locations where high humidity may result in condensation. • Approximately 14 V will be output to the input terminals when the • Locations subject to direct sunlight. H7BX is used with the key protection input terminals and • Locations subject to corrosive gas. no-voltage input (NPN input) is used. To prevent charging • Locations subject to excessive dust or dirt. accidents, connect a diode to the power supply circuit of input • This is a class A product (for industrial environments). In residential devices if input devices are used with a power supply of less than areas, it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. 14 V. • Do not connect loads that exceed the rated output current. The • Use the H7BX within the specified ratings for operating output elements may be destroyed, possibly resulting in temperature and humidity. Temperature rise may shorten the service life of H7BX if it is used near a power supply or other short-circuit or open-circuit faults. • When using heaters, be sure to use a thermal switch for the load heat-generating objects. circuit. • Use the H7BX within the specified ratings for vibration, shock, and splashing water. • Always connect a diode to protect against counter electromotive force when using an inductive load. H7BX electromotive force may • The H7BX is not oil resistant. Do not use it in locations subject to destroy output elements, possibly resulting in short-circuit or oil. • Install the H7BX well away from any sources of excessive static open-circuit faults. • Install a switch or circuit breaker that allows the operator to electricity, such as pipes transporting molding materials, power, or immediately turn OFF the power, and label it to clearly indicate its liquids. • Store the H7BX within the specified ratings. If the H7BX has been function. • Check that the display (backlight and LCD) is operating normally. stored at temperatures of −10°C or lower, let it stand for 3 hours or Some operating environments may accelerate deterioration of the longer at room temperature before turning ON the power supply. indicators, LCD, and resin components and cause display Power Supply malfunctions. Periodically inspect and replace parts. • Maintain voltage fluctuations in the power supply within the specified range. • Internal elements may be destroyed if a voltage beyond the rated voltage is applied. • When the power is turned ON, an inrush current will flow for a short time (approx. 10 A for 2 ms). Depending on the power supply capacity, operation may not start. Be sure to use a power supply with a sufficient capacity. 25 H7BX Precautions for Correct Use • Inrush current generated by turning ON or OFF the power supply may deteriorate contacts in the power supply circuit. Turn ON or OFF using a device with a rated current of 10 A or higher. • Input signals may be accepted, not accepted, or unstable for the following time when the power supply is turned ON or OFF. Set the system to allow leeway in the timing of input signals. ON Power supply OFF 200 ms 0 to 90 ms 5 ms 0 to 1 s Un- Impossible Input Impossible Possible Unstable stable • This H7BX always compares the count value with the set value. Thus, if you change the set value during operation, please remember that the output will turn ON when the set value becomes equal to the count value. • With the factory setting, the output will turn ON when power is supplied to the H7BX because the set value and count value are both zero. While resetting, however, the output stays OFF. • EEPROM is used as memory when the power is interrupted. The write life of the EEPROM is 100,000 writes. The EEPROM is written when settings are changed, or the power is tuned OFF. • Water resistance will be lost if the front sheet is peeled off or torn. Do not use the H7BX if the front sheet is missing or torn. • Abide by all local ordinances and regulations when disposing of the H7BX. • External Power Supply Reduce the load current as shown in the diagram on the right according to the power supply voltage if a DC power supply is used for models specified for 24 VAC/12 to 24 VDC. 100 20 15 0 10.8 Power supply voltage (VDC) 26 Load current (mA) Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. · Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. · Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved.

Related Products

OMRON
Omron CSKE Counter/Timer Modules-Electromagnetic Counter
OMRON
Omron H7ANRW6DM Counter
OMRON
Omron H7CX-A114-N Counter/Timer Modules-48*48mm (1/16 DIN), 11-Pin Socket,...
OMRON
Omron H7CX-A114S-N Counter/Timer Modules-48*48mm (1/16 DIN), 11-Pin Socket,...
OMRON
Omron H7CX-A11D1-N Counter/Timer Modules-48*48mm (1/16 DIN), 11-Pin Socket,...
OMRON
Omron H7CZ Counters/Timer Modules-Multifunction Preset Counter

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.06 seconds.