Industrial Trading chervon right Manufacturers chervon right K chervon right KONTRON chervon right AT8404
About product Specifications Features Datasheet FAQ

KONTRON AT8404

Image of KONTRON AT8404

Description

Kontron AT8404 Carrier Board-As a PICMG 3.0/3.1-compliant AdvancedTCA carrier board,the AT8404 sets a precedent w/ 4 Mid-Size AMC slots that support a full range of AMC modules.

Part Number

AT8404

Price

Request Quote

Manufacturer

KONTRON

Lead Time

Request Quote

Category

Carrier Boards

Specifications

Altitude (Meet or Exceed)

Operating:4,000 m (13,123 ft); Storage and Transit:15,000m / 49,212 ft

AMC Sites

4 Slot carrier; B+ connectors (pressfit); AMC.1 type 4E1S2 on B1/B2/B4 and type 4E1S1 on B3; AMC.2 Type 4E1 on B1, B2, B3, B4; Telecom clocks and/or PCI Express clock support

Building Blocks

Ethernet Switch; Ethernet Switch Controller + Memory; Synchronous Clock Distribution; 4 x AMC sites; RTM sites (Zone 3); IPMI; Power Supply Mezzanine incl. Holdup Circuit

Ethernet Switch

Broadcom BCM56502 StrataXGS Gigabit Switch; 24x 1-GbE ports and 2x 10-GbE ports; 20 ports used for direct connections to each AMC ports 0 and 8 to 11; 2 ports to the RTM; 2 ports to the base interface; 2x 10GbE ports to FI Channel 1 and 2.

Ethernet Switch Controller & System Memory

Socketless AMCC PPC405GPr 400 MHz; 256 MBytes SDRAM 133 MHz; 128 MB Flash (supports multiple OS images); used for switch provisioning and diagnostics

Ethernet/Bridging

Static link aggregation (IEEE 802.3ad); Classic, rapid and multiple spanning tree algorithms shall be supported (IEEE 802.1D, IEEE 802.1w); VLAN tagging (IEEE 802.3ac); Quality Of Service on all ports (IEEE 802.1p); Full Duplex operation and flow control on all ports (IEEE 802.3x); Auto negotiation of speeds and operational mode on all external GE interfaces as well as on the base interfaces; Dynamic L2 multicast registration (GMRP)

Humidity (Meet or Exceed)

Operating:15%-90% (non-condensing) at 55°C (131°F); Storage and Transit:15%-90% (non-condensing) at 55°C (131°F)

Interfaces to AMCs

5 x GbE to AMCs distributed as follows:Common region ports 0 from Ethernet switch; Fat pipe region port 8 to 11 from Ethernet switch. Port 2 & 3 are direct connect to neighbor AMC, B1 to B3 & B2 to B4; Port 4 to 7 are direct connect to neighbor AMC, B1 to B2 & B3 to B4; 7x channels from each AMC slot extended connector ports 13-15 and 17 – 20 to the RTM; AMC port 12 for Automatic Protection Switching (APS) across redundant Carriers (up to 2.5Gbps)

IPMI

HPM.1 protocol to ensure field safe update functionality of the IPMI Controller for field upgrades, rollbacks and watchdog functions; PICMG 3.0 / IPMI 1.5 compliant

Mechanical

(8U x 280 mm x 30.48 mm)

MTBF

Targeted MTBF is 150,000h @ 30°C, calculations based on Bellcore/ Telcordia SR-332 Issue 1

RTM Sites

3 TYCO/ERNI ZD-F-4-10-2-B-22 Connectors.; Support for 7 RTM lanes from each AMC; 10/100Base-T for management; 12V and 3V3sus Supply Voltage connections; I²C support; JTAG and production I/O support

Services/Applicatons

NTP client for retrieving accurate time and date information; Onboard event management; Test and trace facilities; POST (power on self tests) diagnostics; The system shall provide a standards based SNMP implementation supporting SNMP v1, v2 and v3 for monitoring and management of Ethernet; IPMI version 1.5 for board management; IPMI based management of the AMC slots; Persistent storage of configuration across restarts; Support for retrieving and installing multiple configurations; Support for hot-plugging of the carrier board as well as AMCs; Two alternative firmware versions shall be stored allowing for rollback after updates

Shock (Meet or Exceed)

Operating:3G/11 ms half sine; Storage and Transit:18G/6 ms

Standards Compliance

This board is compatible to the following standards:PICMG 3.0/3.1 option 9, AMC.0 rev 2, AMC.2, AMC.3, PCI-Express, SRIO or 10GbE direct AMC interconnect, IPMI v1.5

Synchronous Clock & PCI Express Clock Distribution

Multi-service Line Card PLL; MLVDS Buffer; FPGA for clock distribution and control; PCI Express compliant clock source with optional Spread Spectrum Clock

Temperature (Meet or Exceed)

Operating:0 °C to 55 °C; Storage and Transit:-40 to +70°C / -10 to 158°F

Vibration (Meet or Exceed)

Operating:5 to 100Hz: 1G @ 0.25 Octave/minute; Storage and Transit:Random 0.89Grms (5-200Hz)

Features

Datasheet

pdf file

Kontron=AT8404=datasheet-12581071291.pdf

551 KiB

Extracted Text

R A dvanced TCA AT8404 AdvancedTCA 10GbE fabric carrier with 4 x Mid-Size AdvancedMC slots AdvancedTCA / AdvancedMC Open Modular Solutions PICMG 3.0, PICMG 3.1 option 9 Built for Maximum Design Versatility  compliant carrier board The Kontron AT8404 is one of three key open modular platform elements that complete Kontron’s 10 GbE product portfolio. As a PICMG 3.0/3.1-compliant Four (4) Mid-Size AMC slots that  AdvancedTCA carrier board, the AT8404 sets an industry precedent with 4 support AMC.0 rev 2, AMC.2, Mid-Size AMC slots that support a full range of AMC modules including — TDM AMC.3 interfaces (E1/T1, STM-1, OC3), NPUs, DSPs, PrAMCs and Storage AMCs. PCI-Express, SRIO, SAS/SATA or  AdvancedMC-Everywhere integration for customization 10GbE direct AMC interconnect The Kontron AT8404 provides equipment manufacturers the flexibility to 10GbE redundant Fabric  customize the design of their network system solutions, especially for various Interface 10 GbE-based systems that drive IMS-based broadband applications that require the seamless delivery of video and data content in IPTV or VoD Gigabit Ethernet switching  networks. Telco Clock for all AMC slots  Full Redundancy and High Availability Full Hot-Swap capabilities  Suitable for dual-star configurations in 14- and 16-slot systems, the AT8404 Management via SNMP, TELNET, is hot swappable, supports full redundancy, and provides PCI-Express, SRIO or  CLI, either In-band or Out of 10GbE direct AMC interconnects. For storage solutions, the AT8404 additio- band via 10/100Base-T Ethernet nally provides SAS/SATA direct AMC interconnects. With full IPMI 1.5 support, the AT8404 also implements the HPM.1 protocol to ensure field safe update or RS232 functionality of the IPMI Controller for field upgrades, rollbacks and watchdog IPMI version 1.5 support  functions. If it´s Embedded, it´s Kontron. AT8404 Technical Information Standards Compliance RTM Sites Ethernet This board is compatible to the following standards: - 3 TYCO/ERNI ZD-F-4-10-2-B-22 Connectors. - PICMG 3.0/3.1 option 9 - Support for 7 RTM lanes from each AMC - AMC.0 rev 2, AMC.2, AMC.3 - 10/100Base-T for management - PCI-Express, SRIO or 10GbE direct AMC interconnect - 12V and 3V3sus Supply Voltage connections - IPMI v1.5 - I²C support Building Blocks - JTAG and production I/O support - Ethernet Switch Services/Applications - Ethernet Switch Controller + Memory - NTP client for retrieving accurate time and date information - Synchronous Clock Distribution - Onboard event management - 4 x AMC sites - Test and trace facilities - RTM sites (Zone 3) - POST (power on self tests) diagnostics - IPMI - The system shall provide a standards based SNMP implementation - Power Supply Mezzanine incl. Holdup Circuit supporting SNMP v1, v2 and v3 for monitoring and management of Ethernet Switch Ethernet - Broadcom BCM56502 StrataXGS™ Gigabit Switch - IPMI version 1.5 for board management - 24x 1-GbE ports and 2x 10-GbE ports - IPMI based management of the AMC slots - 20 ports used for direct connections to each AMC ports 0 and 8 to 11 - Persistent storage of configuration across restarts - 2 ports to the RTM - Support for retrieving and installing multiple configurations - 2 ports to the base interface - Support for hot-plugging of the carrier board as well as AMCs - 2x 10GbE ports to FI Channel 1 and 2. - Two alternative firmware versions shall be stored allowing for roll- Ethernet Switch Controller and System Memory back after updates - Socketless AMCC PPC405GPr 400 MHz Ethernet/Bridging - 256 MBytes SDRAM 133 MHz; 128 MB Flash (supports multiple OS - Static link aggregation (IEEE 802.3ad) - Classic, rapid and multiple spanning tree algorithms shall be images); used for switch provisioning and diagnostics supported (IEEE 802.1D, IEEE 802.1w); VLAN tagging (IEEE 802.3ac) Synchronous Clock and PCI Express Clock Distribution - Quality Of Service on all ports (IEEE 802.1p) - Multi-service Line Card PLL - Full Duplex operation and flow control on all ports (IEEE 802.3x) - MLVDS Buffer - Auto negotiation of speeds and operational mode on all external GE - FPGA for clock distribution and control interfaces as well as on the base interfaces - PCI Express compliant clock source with optional Spread - Dynamic L2 multicast registration (GMRP) Spectrum Clock Interfaces to AMCs Environmental - 5 x GbE to AMCs distributed as follow: Operating Storage and Transit - Common region ports 0 from Ethernet switch -40 to +70°C / -10 to Temperature*: 0 °C to 55 °C - Fat pipe region port 8 to 11 from Ethernet switch 158°F* - Port 2 & 3 are direct connect to neighbor AMC, B1 to B3 & B2 to B4 15%-90% (non-conden- 15%-90% (non-conden- Humidity*: - Port 4 to 7 are direct connect to neighbor AMC, B1 to B2 & B3 to B4 sing) at 55°C (131°F) sing) at 55°C (131°F) - 7x channels from each AMC slot extended connector ports 13-15 and Altitude*: 4000 m (13,123 ft) 15,000m / 49,212 ft 17 – 20 to the RTM - AMC port 12 for Automatic Protection Switching (APS) across 3G/11 ms half sine Shock*: 18G/6 ms redundant Carriers (up to 2.5Gbps) 5 to 100Hz: 1G @ 0.25 Random 0.89Grms Vibration*: IPMI Octave/minute (5-200Hz) - HPM.1 protocol to ensure field safe update functionality of the IPMI *Meet or exceed Controller for field upgrades, rollbacks and watchdog functions Targeted MTBF is 150,000h @ 30°C, calculations based on Bellcore/ - PICMG 3.0 / IPMI 1.5 compliant Telcordia SR-332 Issue 1 AMC Sites Mechanical - 4 Slot carrier (8U x 280 mm x 30.48 mm) - B+ connectors (pressfit) - AMC.1 type 4E1S2 on B1/B2/B4 and type 4E1S1 on B3 - AMC.2 Type 4E1 on B1, B2, B3, B4 - Telecom clocks and/or PCI Express clock support Corporate Offices US/ Canada Asia Pacific Europe, Middle East & Africa 14118 Stowe Dr Far East Science Park, 2nd Floor No.2, Lane50, Oskar-von-Miller-Straße 1 85386 Eching/Munich - Germany Poway, CA 92064-7147 Nan Kang Road Section 3 Nan Kang District Taipei, Taiwan Tel.: +49 (0)8165 77 0 Tel.: (858) 677-0877 Tel: +886 2 2782 0201 Fax: (858) 677-0898 Fax: +886 2 2782 7486 Fax: +49 (0)8165 77 279 sales@us.kontron.com sales@kontron.com.tw sales@kontron.com www.kontron.com AT8404 - Doc V 1.1 - 2007 All data is for information purposes only and not guaranteed for legal purposes. Subject to change without notice. Information in this datasheet has been carefully checked and is believed to be accurate; however, no responsibilty is assumed for inaccurancies. All brand or product names are trademarks or registered trademarks of their respective owners.

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the AT8404?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Kontron Evaluation carrier board for ETXexpress modules with 10/100Base-T Ethernet

product

Kontron Evaluation carrier board for ETXexpress modules with 10/100/1000Base-Tx (Gigabit) Ethernet

product

Kontron AT8402 Carrier Board-The AT8402 carrier board is a PICMG 3.0 and 3.1 compliant node board fo...

product

Kontron ETXexpress Eval - Evaluation Carrier Board -- Type 2 ETXexpress modules

product

KONTRON PB-ADC3 Carrier Board - 8 channel optoisolated piggyback for differential analog inputs rang...

product

Kontron VMOD-4D Carrier Board - Providing up to 4 ModPack interface in a 6U form factor, the VMOD-4D...