General Electric BCLL11 Auxiliary Contact. Side-Mount | 1NO-1NC | Standard (5 to 500 Hp)

Part Number

BCLL11

Price

Request Quote

Manufacturer

GENERAL ELECTRIC

Lead Time

Request Quote

Category

Auxiliary Contact

Datasheet

pdf file

CL07A300M_Datashee-1528282419t.pdf

1358 KiB

Extracted Text

SERIES CL - CK - Contactors Contactors Series CL A=AC D=DC Housing E = DC/AC with electronic module 00 05 01 06 Auxiliary 02 07 contacts NO 25 08 Type 03 09 identification Auxiliary 04 10 contacts NC 45 Control voltage 2 .5 C L 3 = 3-pole T = screw terminal � Contactor (see 2.11) M = double clamp 4 = 4-pole NO terminal � Auxiliary contacts side-mounted (see 2.15) B = 4-pole 2NO + 2NC � Mechanical interlock (see 2.15) Contactors Series CK Auxiliary contacts front-mounted (see 2.15) � Electronic timer block (see 2.16) � Transient voltage suppressor block (see ie 2.16) � Mechanical latch block (see 2.15) � � Pneumatic timer block (see 2.15) � Thermal overload relay (see 2.22) A=AC Housing E = DC/AC with electronic module 07 10 75 11 Auxiliary Type 08 12 contacts NO identification 85 13 Auxiliary 09 contacts NC 95 Control voltage C K Version 3 = 3-pole (B, C) 4 = 4-pole (4NO) Thermal overload relay RT Type identification Setting range (A...W) R T Housing = class 10A (RT1) – class 10 (RT2, RT3, RT4, RT5, RT6) 2 = class 20 (RT1. RT2. RT3) = class 30 (RT4, RT5, RT6) L SERIES CL - Contactors Control circuit: alternating current Three-pole contactors (1) from 9 to 105A (AC3) Max. operat. current Admissible power AC3 Elec. endur. Aux. contacts Cat. no. Weight Non- Motors 220V 380V 415V 500V Category – Power circuit (AC): up to 690V •3 •1 inductive ≤ ≤ ≤ 440V 230V 400V 440V AC3 ≤ ≤ – Control circuit: load 3-phase Alternating current up to 690V AC 50/60 Hz •4 •2 – Terminal numbering in accordance with AC1 AC3 EN 50005 and EN 50012 A A kW kW kW kW # ops. – Fixing by clipping onto 35 mm DIN rail 6 EN 50022-35 or by screws 25 9 2.2 4 4 5.5 2 x 10 0 0 CL00A300T � 0.280 – Degree of protection CL00... to CL02... : IP20 10 CL00A310T � 0.295 CL25... to CL10... : IP10 01 CL00A301T � 0.295 – Screws protected against accidental contact in 6 25 12 3 5.5 5.5 7.5 2 x 10 0 0 CL01A300T � 0.280 accordance with VDE 0106. 10 CL01A310T � 0.295 – Three coil terminals. 01 CL01A301T � 0.295 – Accessories: 6 32 18 4 7.5 7.5 10 1.7 x 10 0 0 CL02A300T � 0.280 Mounting possibilities of front/side 10 CL02A310T � 0.295 instantaneous auxiliary contact blocks, timed 01 CL02A301T � 0.295 auxiliary contact blocks, mechanical latch, 2 6 transient suppressor block and interface 45 25 7.5 11 11 15 2 x 10 00 CL25A300T � 0.270 modules 1 0 CL25A310T �(2) 0.285 .11 – Maximum number of auxiliary contacts: 0 1 CL25A301T �(2) 0.285 four for CL00...CL25 6 45 25 7.5 12 12 15 2 x 10 10 CL03A310M � 0.490 six for CL03...CL45 01 CL03A301M � 0.490 eight for CL06...CL10 6 60 32 9 16 16 18.5 2 x 10 0 0 CL04A300M � 0.500 10 CL04A310M � 0.520 01 CL04A301M � 0.520 6 60 40 11 18.5 22 25 2 x 10 00 CL45A300M � 0.490 CL00A310TN 1 1 CL45A311M �(3) 0.540 6 90 50 15 22 25 30 1.8 x 10 00 CL06A300M � 1.075 1 1 CL06A311M �(3) 1.105 6 110 65 18.5 30 37 40 1.7 x 10 00 CL07A300M � 1.090 1 1 CL07A311M �(3) 1.120 6 110 80 22 37 45 45 1.5 x 10 00 CL08A300M � 1.110 1 1 CL08A311M �(3) 1.130 6 140 95 25 45 50 55 1.7 x 10 00 CL09A300M � 1.000 1 1 CL09A311M �(3) 1.450 CL45A300MN 6 140 105 30 55 55 65 1.5 x 10 00 CL10A300M � 1.440 1 1 CL10A311M �(3) 1.470 Spare coils Alternating current CL00 - CL25 LB1A� 0.063 CL03 - CL45 LB3A� 0.102 CL06 - CL10 LB4A � 0.145 (1) Available coil voltages Alternating current (V) � C D FG J KM N R U VW X Y Z CL07A300MN 50Hz 24 42 48 110 220 240 380 415 440 500 660 230 400 690 (1) To complete the catalogue number, replace the symbol � by the code corresponding to the voltage and frequency of the control circuit. (2) Equipped with one block BCLF (see 2.15) (3) Equipped with two blocks BCLF (see 2.15) Thermal overload relay, see 2.22 Technical specifications, see 2.34 Dimensions, see 2.44 SERIES CL - Contactors Control circuit: direct current Three-pole contactors (1) from 9 to 105A (AC3) Max. operat. current Admissible power AC3 Elec. endur. Aux. contacts Cat. no. Weight Non- Motors 220V 380V 415V 500V Category – Control circuit : •3 •1 inductive ≤ ≤ ≤ 440V 230V 400V 440V AC3 ≤ ≤ Direct current up to 440V load 3-phase – Terminal numbering in accordance with 50/60 Hz •4 •2 EN 50005 and EN 50012 AC1 AC3 – Fixing by clipping onto 35 mm DIN rail A A kW kW kW kW operations EN 50022-35 or by screws 6 – Degree of protection CL00... to CL02... : IP20 25 9 2.2 4 4 5.5 2 x 10 10 CL00D310T � � � � � 0.490 CL25... to CL10... : IP10 01 CL00D301T � � � � � 0.490 – Screws protected against accidental contact in 6 25 12 3 5.5 5.5 7.5 2 x 10 10 CL01D310T � � � � � 0.490 accordance with VDE 0106. 01 CL01D301T � � � � � 0.490 – Three coil terminals. 6 32 18 4 7.5 7.5 10 1.7 x 10 10 CL02D310T � � � � � 0.490 – The types CL...E are also suitable for AC 01 CL02D301T � � � � � 0.490 control. 6 – Accessories: 45 25 7.5 11 11 15 2 x 10 00 CL25D300T � � � � � 0.480 Mounting possibilities of front/side 6 instantaneous auxiliary contact blocks, timed � � 45 25 7.5 12 12 15 2 x 10 10 CL03D310M � � � 0.480 2 auxiliary contact blocks, mechanical latch, 01 CL03D301M � � � � � 0.480 .12 transient suppressor block and interface 6 60 32 9 16 16 18.5 2 x 10 10 CL04D310M � � � � � 0.835 modules 01 CL04D301M � � � 0.835 � � – Maximum number of auxiliary contacts: 6 60 40 11 18.5 22 25 2 x 10 00 CL45D300M � � � � � 0.825 four for CL00...CL25 six for CL03...CL45 6 eight for CL06...CL10 90 50 15 22 25 30 1.8 x 10 00 CL06E300M � � � � � 1.095 CL00D310TD 6 110 65 18.5 30 37 40 1.7 x 10 00 CL07E300M � � � � � 1.110 6 110 80 22 37 45 45 1.5 x 10 00 CL08E300M � � � � � 1.120 6 140 95 25 45 50 55 1.7 x 10 00 CL09E300M � � � � � 1.440 6 140 105 30 55 55 65 1.5 x 10 00 CL10E300M � � � 1.460 � � Spare coils (pure DC coil) CL00 - CL25 LB1D � � � � � 0.205 (pure DC coil) CL03 - CL45 LB3D � � � � � 0.276 (coil + electronic module) CL06 - CL10 LB4E � � � � � 0.610 (1) Available coil voltages Direct current (V). For contactors type CL...D / Operating limits: 0.80 ... 1.10 x Us � � B D EF G HI J KN PR X � � � Voltage 12 24 42 48 110 120 220 240 125 Direct current (V). Coil with electronic module for contactors CL...E (²) / Operating limits: 0.80 ... 1.10 x Us � � � � � DF H J NY Voltage 24 42 110 220 28 48 125 250 (1) To complete the catalogue number, replace the symbol � � � � � by the code corresponding to the voltage and frequency of the control circuit. (2) Can also be used with alternating current. Thermal overload relay, see 2.22 Technical specifications, see 2.34 Dimensions, see 2.44 SERIES CL - Contactors Control circuit: alternating current Four-pole contactors (4NO) (1) from 25 to 140A (AC1) Maximum operating Admissible Electrical Control Power Cat. no. Weight current power AC1 endurance circuit contacts – Power circuit (AC): up to 690V Non- 220V 380V 415V 500V Category – Control circuit: inductive 230V 400V 440V AC1 Alternating current up to 690V AC load Direct current up to 440V DC AC1 AC3 – Terminal numbering in accordance with A A kW kW kW kW operations EN 50005 and EN 50012 6 – Fixing by clipping onto 35 mm DIN rail 25 12 9.5 16.5 18 21.5 1.5 x 10 AC 4 0 CL01A400T � � � 0.280 � � (EN 50022-35) or by screws. 6 32 18 12 22 23 27.5 1.5 x 10 AC 4 0 CL02A400T � � � � � 0.280 – Degree of protection CL01... to CL02... : IP20 6 45 25 17 29 32 39 2 x 10 AC 4 0 CL03A400M � � � � � 0.490 CL03... to CL09... : IP10 6 60 32 22.5 39.5 43 52 1.5 x 10 AC 4 0 CL04A400M � � � � � 0.500 – Screws protected against accidental contact in 6 accordance with VDE 0106. 90 50 34 59 64 78 1.5 x 10 AC 4 0 CL05A400M � � � � � 1.240 – Three coil terminals. 6 110 65 42 72.5 79 95 1.8 x 10 AC 4 0 CL07A400M � � � � � 1.270 – The types CL...E are also suitable for AC 6 140 95 53 92 100 121 1.8 x 10 AC 4 0 CL09A400M � � � 1.450 � � control. – Accessories: 2 Spare coils CL01 - CL02 LB1A � � � � � 0.063 Mounting possibilities of front/side instantaneous CL03 - CL04 LB3A � � � � � 0.102 auxiliary contact blocks, timed auxiliary contact .13 CL05 - CL09 LB4A � � � � � 0.145 blocks, mechanical latch, transient suppressor block and interface modules. Control circuit: direct current 6 25 12 9.5 16.5 18 21.5 1.5 x 10 DC 4 0 CL01D400T � � 0.490 � � � CL01A400TN 6 32 18 12 22 23 27.5 1.5 x 10 DC 4 0 CL02D400T � � � � � 0.490 6 45 25 17 29 32 39 2 x 10 DC 4 0 CL03D400M � � � � � 0.825 6 60 32 22.5 39.5 43 52 1.5 x 10 DC 4 0 CL04D400M � � � � � 0.835 6 90 50 34 59 64 78 1.5 x 10 AC/DC 4 0 CL05E400M � � � � � 1.290 6 � � 110 65 42 72.5 79 95 1.8 x 10 AC/DC 4 0 CL07E400M � � � 1.290 6 � � 140 95 53 92 100 121 1.8 x 10 AC/DC 4 0 CL09E400M � � � 1.500 � � Spare coils (pure DC coil) CL00 - CL02 LB1D � � � 0.205 (pure DC coil) CL03 - CL04 LB3D � � � 0.276 � � (coil + electronic module) CL05 - CL09 LB4E � � 0.610 � � � CL05A400MN (1) Available coil voltages Alternating current (V) � � � � � C D FG H J KM N R ST U VW X Y Z 50Hz 24 42 48 110 127 220 240 380 415 440 500 660 230 400 690 (4) CL09E400MJ Direct current (V). For contactors type CL...D / 0.80 ... 1.10 x Us � � � � � B D EF G HI J KN PR X Voltage 12 24 42 48 110 120 220 240 125 (3) (4) Direct current (V). Coil with electronic module for contactors type CL...E / 0.80 ... 1.10 x Us � � � � � DF H J NY Voltage 24 42 110 220 28 48 125 250 (1) To complete the catalogue number, replace the symbol � � � � � by the code corresponding to the voltage and frequency of the control circuit. (2) Only for CL00 to CL45. Thermal overload relay, see 2.21 Technical specifications, see 2.34 Dimensions, see 2.44 SERIES CL - Contactors Control circuit: alternating current Four-pole contactors (1) (2NO + 2NC) Max. operat. current Admissible power AC3 Control Power contacts Cat. no. Weight Non- Motors 220V 380V 415V 500V from 12 to 80A (AC3) inductive ≤ ≤ ≤ 440V, 230V 400V 440V ≤ ≤ – Power circuit (AC): up to 690V load 3-phase – Control circuit: 50/60 Hz Alternating current up to 690V AC AC1 AC3 Direct current up to 440V DC A A kW kW kW kW – Terminal numbering in accordance with 25 12 3 5.5 5.5 7.5 AC 2 2 CL01AB00T � � � � � 0.280 EN 50005 and EN 50012 32 18 4 7.5 7.5 10 AC 2 2 CL02AB00T � � � � � 0.280 – Fixing by clipping onto 35 mm DIN rail (EN 50022-35) or by screws. 45 25 7.5 12 12 15 AC 2 2 CL03AB00M � � � � � 0.490 – Degree of protection CL01... to CL02...: IP20 60 32 9 16 16 18.5 AC 2 2 CL04AB00M � � � � � 0.500 CL03... to CL09...: IP10 � � 90 40 11 18.5 22 25 AC 2 2 CL05AB00M � � � 1.240 – Screws protected against accidental contact in accordance with VDE 0106. 110 65 18.5 30 37 40 AC 2 2 CL07AB00M � � � 1.270 � � – Three coil terminals. 110 80 22 37 45 45 AC 2 2 CL08AB00M � � � 1.270 � � – The types CL...E are also suitable for AC control. 2 Spare coils CL01 - CL02 LB1A � � � � � 0.063 – Accessories: CL03 - CL04 LB3A � � � � � 0.102 .14 Mounting possibilities of front/side instantaneous CL05 - CL08 LB4A � � � � � 0.145 auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor Control circuit: direct current block and interface modules. 25 12 3 5.5 5.5 7.5 DC 2 2 CL01DB00T � � � 0.490 � � 32 18 4 7.5 7.5 10 DC 2 2 CL02DB00T � � � � � 0.490 CL01AB00TN 45 25 7.5 12 12 15 DC 2 2 CL03DB00M � � � � � 0.825 60 32 9 16 16 18.5 DC 2 2 CL04DB00M � � � � � 0.835 90 40 11 18.5 22 25 DC/AC 2 2 CL05EB00M � � � � � 1.290 110 65 18.5 30 37 40 DC/AC 2 2 CL07EB00M � � � � � 1.320 110 80 22 37 45 45 DC/AC 2 2 CL08EB00M � � � 1.320 � � � � Spare coils (pure DC coil) CL00 - CL02 LB1D � � � 0.205 (pure DC coil) CL03 - CL04 LB3D � � � � � 0.276 (coil + electronic module) CL05 - CL08 LB4E � � � 0.610 � � CL05EB00MJ (1) Available coil voltages Alternative current (V) � � � � � C D FG HJ KM N R ST U VW XYZ 50Hz 24 42 48 110 127 220 240 380 415 440 500 660 230 400 690 Direct current (V). For contactors type CL...D � � � � � B D EF G HI J KN PR X Voltage 12 24 42 48 110 120 220 230 240 125 Direct current (V). Coil with electronic module for contactors type CL...E (³) � � � � � DF H J NY Voltage 24 42 110 220 28 48 125 250 (1) To complete the catalogue number, replace the symbol � � � � � by the code corresponding to the voltage and frequency of the control circuit. (2) Only for CL00 to CL45. Technical specifications, see 2.34 Dimensions, see 2.44 SERIES CL - Accessories Instantaneous auxiliary contact blocks BCLF10 – Terminal numbering in accordance with EN 50005 and EN 50012 – Terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 : IP20. – Combinations for contactors and front/side mounted auxiliary contact blocks, see pages K.42 and K.43 For use with Mounting Type Contacts Cat. no. Weight 3 •1 •7 •5 • •4 •2 •8 •6 CL00...CL10 Front one pole 1 0 0 0 BCLF10 0.015 BCLL11 01 0 0 BCLF01 0.015 0 0 1 0 BCLF10G 0.015 0 0 0 1 BCLF01G 0.015 CL00...CL10 Side two pole 2 0 0 0 BCLL20 0.048 11 0 0 BCLL11 0.048 (1) CL00...CL10 Side two pole 2 0 0 0 BRLL20 0.048 11 0 0 BRLL11 0.048 2 (1) For combinations of more than 4 front-mounted and 2 side-mounted auxiliary contact blocks .15 Pneumatic timer auxiliary contact blocks BTLF30C For use with Mounting Type Contacts Time Cat. no. Weight •7 •5 •6 •8 CL00...CL10 Front Delayed 1 1 0.1...30 s. BTLF30C 0.085 ON 1 1 1.0...60 s. BTLF60C 0.085 CL00...CL10 Front Delayed 1 1 0.1...30 s. BTLF30D 0.085 OFF 1 1 1.0...60 s. BTLF60D 0.085 Sealing cover protection for pneumatic timer BTLFX 0.001 RMLFN Mechanical latch blocks – Terminal numbering in accordance with EN 50005 – Disconnection of the contactor or auxiliary contactor, either using an electrical pulse or manually. – Terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 – Frontal selector allows for adaptation in function of the housing of the contactor. (2) For use with Cat. no. Weight � � CL00...CL10 RMLF � � � 0.082 BEL (2) To complete the catalogue number, replace the symbol � � � � � by the code corresponding to the voltage and frequency of the control circuit. � � � � � DG HC J N UY 50 Hz 24, 32 42, 48 110, 115, 120, 127 220, 230, 240, 380, 400, 415, 440, 480 500, 660/690 DC 32, 36 42, 48 110, 120, 220, 240, 250 Mechanical and mechanical/electrical interlock Side mounted to the contactor BEL02 For use with Type Cat. no. Weight CL00...CL45 Mechanical BELA 0.025 CL05...CL10 Mechanical BEL 0.025 CL00...CL45 Mech./electrical BELA02 0.025 CL05...CL10 Mech./electrical BEL02 0.025 Technical specifications, see 2.34 Dimensions, see 2.44 SERIES CL - Accessories Transient voltage suppressor block BSLR2R Directly connected parallel to the coil terminals A1-A2 Control circ. For use with Type Ue Cat. no. Weight AC CL00...CL45... R/C 24V...48V BSLR2G 0.020 50V...127V BSLR2K 0.020 130V...240V BSLR2R 0.020 AC CL05A...CL10A... R/C 24V...48V BSLR3G 0.020 50V...127V BSLR3K 0.020 130V...240V BSLR3R 0.020 DC CL...D... Diode 12V...600V BSLDZ 0.020 AC/DC CL... Varistor 24V...48V BSLV3G 0.020 50V...127V BSLV3K 0.020 130V...240V BSLV3R 0.020 277V...500V BSLV3U 0.020 Electronic timer module BETL45C Directly connected parallel to the coil terminals A1-A2 2 Control circ. For use with Type Time Cat. no. Weight .16 24-250V AC/DC CL00 to CL10 Delayed ON 0.1...2 s. BETL02C 0.040 1.5...45 s. BETL45C 0.040 Delayed OFF 0.1...2 s. BETL02D 0.040 1.5...45 s. BETL45D 0.040 Interface module IMRD Directly connected parallel to the coil terminals A1-A2 Control circ. For use with Type Ue (DC) Cat. no. Weight 24-250V AC CL00 to CL10 Relay 24V IMRD 0.060 24-250V DC CL00 to CL45 48V IMRG 0.060 Relay + 24V IMRFD 0.050 forced operation 48V IMRFG 0.050 Solid state 24V IMSSD 0.045 Auto / Manual / IMAMS 0.045 Off control Transient voltage suppressor block to use with interface modules IMRC2R To be plugged inside the interface module or inside the electronic timer module. For use with Type Con. circ. AC/DC Cat. no. Weight CL00...CL45... R/C 24V...48V IMRC2G 0.020 50V...127V IMRC2K 0.020 130V...240V IMRC2R 0.020 CL05A...CL10A... R/C 24V...48V IMRC3G 0.020 50V...127V IMRC3K 0.020 130V...240V IMRC3R 0.020 CL...D... Diode 12V...600V IMD1Z 0.020 CL... Varistor 24V...48V IMV3G 0.020 50V...127V IMV3K 0.020 130V...240V IMV3R 0.020 Pole terminal protector IP xxB For use with Mounting Cat. no. Weight CL03...CL04... Single pole IPxxB PTP04 CL45... Single pole IPxxB PTP45 CL05...CL08... Single pole IPxxB PTP08 CL09...CL10... Single pole IPxxB PTP10 Identification Sheets of labels (10 sheets of 260 labels each) EAT260 0.050 Labeling plate base (50 pieces in one pack) SPR 0.001 Technical specifications, see 2.34 Dimensions, see 2.44 SERIES CL - Accessories Alternating current Coils (1) CL...A For use with Cat. no. Weight LB4AN CL00...CL25 LB1A � 0.063 CL03...CL45 LB3A � 0.102 CL05...CL10 LB4A � 0.145 Alternating current (V) � C D FG HJ KM N RS TU VW XYZ 50Hz 24 42 48 110 220 240 380 415 440 500 660 230 400 690 (1) To complete the catalogue number, replace the symbol � by the corresponding code. (2) Direct current (1) CL...D For use with Cat. no. Weight CL00...CL25 LB1D � 0.205 2 CL03...CL45 LB3D � 0.276 .17 u B D F G HI J KN PR X Voltage 12 12 24 42 48 110 220 240 (1) To complete the catalogue number, replace the symbol � by the corresponding code. (2) Direct current (V) with electronic module (also for use with alternating current) (1) CL...E For use with Cat. no. Weight CL05...CL10 LB4E � 0.610 � DF H J NY Voltage 24 42 60 220 440 28 48 125 250 (1) To complete the catalogue number, replace the symbol � by the corresponding code. (2) Operating limits 0.80 up to 1.10 x Us. (1) Contact kits For use with Number of sets Type Cat. no. Pack Weight CL00... 3 NO V31200B 1 0.025 CL01...3..., CL01...4... 3 NO V31201B 1 0.025 CL01...B 4 2NO-2NC VB1201B 1 0.035 CL02...3, CL02...4... 3 NO V31202B 1 0.025 CL02...B... 4 2NO-2NC VB1202B 1 0.035 CL25...3... 3 NO V31225B 1 0.035 CL03...,CL03...4... 3 NO V31203B 1 0.035 CL03...B... 4 2NO-2NC VB1203B 1 0.050 CL04...3..., CL04...4... 3 NO V31204B 1 0.035 CL04...B 4 2NO-2NC VB1204B 1 0.050 CL45...3... 3 NO V31245B 1 0.035 CL05...4... 4 NO V31205B 1 0.080 CL05...B... 4 2NO-2NC VB1205B 1 0.100 CL06... 3 NO V31206B 1 0.080 CL07...3..., CL07...4... 3 NO V31207B 1 0.090 CL07...B... 4 2NO-2NC VB1207B 1 0.110 CL08...3... 3 NO V31208B 1 0.090 CL08...B... 4 2NO-2NC VB1208B 1 0.110 CL09... 3 NO V31209B 1 0.120 CL10... 3 NO V31210B 1 0.130 (1) One set consists of two fixed contacts, one moving contact and accessory parts. SERIES CL - Technical data Power circuit Three-pole version CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10 Rated thermal current Ith at θ ≤ 55°C (A) 25 25 32 45 45 60 60 90 110 110 140 140 Rated operational current Ie (A) 9 12 18 25 25 32 40 50 65 80 95 105 Rated operational voltage Ue (V) 690 690 690 690 690 690 690 690 690 690 690 690 Four-pole version (4 NO and 2 NO + 2 NC) CL01 CL02 CL03 CL04 CL05 CL07 CL08(1) CL09(2) Rated thermal current Ith at θ ≤ 55°C (A) 25 32 45 60 90 110 110 140 Rated operational voltage Ue (V) 690 690 690 690 690 690 690 690 (1) 2 NO + 2 NC only (2) 4 NO only Three-pole and four-pole version 2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10 .35 Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Maximum continuous current AC1 (A) 25 25 32 45 45 60 60 90 90 110 110 140 140 Frequency limits (Hz) 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 25..400 Making capacity (RMS) (acc. IEC 947) (A) 450 450 450 450 550 550 550 1000 1000 1000 1000 1280 1280 Breaking capacity (RMS) (acc. IEC 947) Ue ≤ 400V (A) 250 250 250 350 450 450 450 920 920 920 920 1050 1050 Ue = 500V (A) 250 250 250 320 450 450 450 920 920 920 920 1050 1050 Ue = 690V (A) 130 130 130 170 205 205 205 780 780 780 780 950 950 Short-time current 1 sec. (A) 455 455 570 630 1010 1010 1265 1580 1580 2530 2530 3300 3300 5 sec. (A) 205 205 254 280 450 450 450 565 710 1130 1130 1485 1485 10 sec. (A) 144 144 180 200 320 320 400 500 500 800 800 1050 1050 30 sec. (A) 85 85 104 115 185 185 230 290 290 460 460 600 600 1 min. (A) 60 60 74 80 130 130 165 205 205 325 325 430 430 3 min. (A) 35 35 46 50 90 90 100 120 120 185 185 250 250 Recovery time (min.) 10 10 10 10 10 10 10 10 10 10 10 10 10 Protection against short-circuits with fuses Coordination type "2" aM (A) 10 12 20 25 25 35 40 40 50 80 80 125 160 gL-gG (A) 25 35 35 50 63 63 63 100 100 160 160 200 200 Without welding aM (A) 8 8 16 20 202025 35 40 50 508080 gL-gG (A) 10 10 25 35 35 35 50 80 80 100 100 160 160 Impedance per pole (mΩ) 2.35 2.35 2.41 1.65 1.28 1.28 0.95 0.85 0.85 0.86 0.86 0.76 0.76 Power dissipation per pole AC1 (W) 1.47 1.47 2.46 3.34 2.59 4.6 3.42 6.89 6.89 10.4 10.4 14.89 14.89 AC3 (W) 0.19 0.34 0.78 1.03 0.80 1.31 1.52 1.36 2.12 3.63 5.5 6.86 8.37 Insulation resistance Between adjacent poles (MΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 Between poles and earth (MΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 Between input and output (MΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 SERIES CL - Technical data Electrical endurance Category AC1 Category AC4 7 10 4 Number of Number of 8 operations operations 6 2 4 6 10 2 8 6 6 10 4 8 6 A A 2 4 Ic=Ie 12 24 36 48 60 120 240 360 480 600 for all tensions 2 4 6 8 10 20 40 60 80 100 200 400 54 72 108 150192 300 540 630 2 220/230V kW Category AC2 .36 Rated motor kW 380/400V power 2 Number of (Ic = 6 Ie) operations kW 415/440V 6 10 8 6 4 2 5 10 8 A Mixed category AC4/AC3 6 2 4162 80 0 40 60 80 100 200 Electrical endurance for mixed category (AC3/AC4) is calculated with the 9 12 18 2532 5065 95105 following formula : kW 220/230V Rated motor 380/400V kW power (Ic = 2.5 Ie) kW 415/450V Category AC3 7 10 Number of 8 operations 6 4 2 6 10 8 6 4 A 2462 810 0 40 60 80 100 200 9 12 18 2532 5065 95105 220/230V kW Rated motor 380/400V kW power (Ic = Ie) kW 415/440V CL00 1.1 1.1 1.1 1.1 0.55 0.55 CL01 1.5 1.5 0.75 1.5 1.5 0.75 CL00 CL00 2.2 CLO2 2.2 CL01 CL01 2.2 1.1 2.2 1.1 CLO2 CLO2 1.5 1.5 3.7 3.7 3.7 CL25-CL03 3.7 4 4 2.2 2.2 4 4 CL25-CL03 CL25-CL03 CL04 5.5 5.5 5.5 3 5.5 3 CL04 CL04 CL45 7.5 7.5 CL45 CL45 4 4 7.5 7.5 CL06 CL06 CL06 CL07 5.5 5.5 11 11 CL07 CL07 11 11 7 7 CL08 CL08 CL08 15 15 7.5 7.5 15 15 CL09 CL09 CL09 18.5 18.5 18.5 18.5 CL10 CL10 CL10 11 11 22 22 22 22 25 15 25 15 18.5 18.5 30 30 30 30 37 37 37 22 37 22 45 45 45 45 25 25 55 55 55 30 55 30 37 37 75 75 75 75 45 45 90 90 90 90 55 55 100 100 CL00 1.1 1.1 0.55 CL01 0.75 1.5 1.5 CLO2 2.2 2.2 1.1 1.5 3.7 3.7 CL25-CL03 4 2.2 4 CL04 5.5 5.5 3 CL45 7.5 7.5 4 CL06 CL07 5.5 11 11 7 CL08 15 7.5 15 CL09 18.5 18.5 CL10 11 22 22 25 15 18.5 30 30 37 22 37 45 45 25 55 30 55 37 75 75 45 90 90 55 100 110 SERIES CL - Technical data Control circuit Three-pole and four-pole contactors Alternating current CL00...CL25 CL03...CL45 CL05...CL08 CL09...CL10 Rated insulation voltage Ui (V) 1000 1000 1000 1000 Standard voltages Us 50 Hz (V) 24...690 24...690 24...690 24...690 Voltage operating limits monofrequency coils Operating xUs 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 Pick-up xUs 0.6...0.8 0.65...0.8 0.65...0.8 0.65...0.8 Seal xUs 0.35...0.55 0.4...0.6 0.4...0.6 0.4...0.6 Consumption monofrequency coils Seal (VA) 6 9 15.5 15.5 Pick-up (VA) 45 88 191 191 Thermal power dissipation (50 Hz/60 Hz)) (W) 2 / 1.7 2.8 / 3.3 4.5 / 3.9 4.5 / 3.9 Power factor Magnetic circuit closed (cos j) 0.39 0.31 0.35 0.35 Magnetic circuit open (cos j) 0.82 0.76 0.64 0.64 Opening and closing times Values between + 10 % Us and – 20 % Us 2 Making time on excitation (NO contact) (ms) 6...20 7...25 9...35 9...35 Breaking time on de-excitation (NO contact) (ms) 6...13 5...25 9...15 9...15 .37 Values at Us Making time on excitation (NO contact) (ms) 8...20 10...19 15...30 15...30 Breaking time on de-excitation (NO contact) (ms) 6...13 5...25 9...15 9...15 Mechanical endurance 6 Monofrequency coils 10 ops. 15 15 15 15 6 Bifrequency coils (at 50 Hz)10 ops. 10 10 8 8 Maximum rate Monofrequency coils no load ops./h 9000 9000 9000 5000 AC1 at rated power ops./h 1200 1200 1200 1200 AC2 at rated power ops./h 1000 1000 1000 750 AC3 at rated power ops./h 1200 1200 1200 600 AC4 at rated power ops./h 360 360 200 200 Direct current CL00D...CL25D CL03D...CL45D CL05E...CL08E CL09E...CL10E Rated insulation voltage Ui (V) 1000 1000 1000 1000 Standard voltages Us (V) 12...440 12...440 24...440 24...440 Operating limits Operating xUs 0.8...1.1 0.8...1.1 0.8...1.1 0.8...1.1 Pick-up xUs 0.45...0.65 0.45...0.65 0.70...0.80 0.70...0.80 Drop-out xUs 0.15...0.3 0.15...0.3 0.4...0.6 0.4...0.6 Consumption Magnetic circuit closed (W) 5.5 8 10 10 Magnetic circuit open (W) 5.5 8 170 170 Opening and closing times Values between + 10 % Us and – 20 % Us Making time on excitation (NO contact) (ms) 35...65 35...70 60...80 60...80 Breaking time on de-excitation (NO contact) (ms) 6...15 40...65 40...50 40...50 Values at Us Making time on excitation (NO contact) (ms) 35...45 40...55 50...60 50...60 Breaking time on de-excitation (NO contact) (ms) 7...12 30...65 55...60 55...60 6 Mechanical endurance 10 ops. 15 15 12 12 Maximum rate No load ops./h 3600 3600 2500 2500 AC1 and AC3 at rated power ops./h 1200 1200 1200 600 AC4 at rated power ops./h 360 360 200 200 SERIES CL - Technical data Internal auxiliary contacts CL00...CL02 CL03-CL04 Rated insulation voltage Ui according to IEC 947 (V) 1000 1000 Rated thermal current Ith at θ ≤ 55°C (A) 20 20 Making capacity (r.m.s.) according to IEC 947 AC15/AC11 Ue ≤ 400V, 50/60 Hz (A) 250 250 DC13/DC11 Ue ≤ 220V DC (A) 250 250 Breaking capacity (r.m.s.) according to IEC 947 AC15/AC11 Ue ≤ 400V, 50/60 Hz (A) 250 250 DC13/DC11 Ue ≤ 220V DC (A) 2 2 AC 15 Rated voltage and current Ue-Ie according to IEC 110/120V-10A 220/230V-10A 110/120V-10A 230/220V-10A 400/380V-6A 415/450V-5A 400/380V-6A 415/450V-5A 500V-4A 690/660V-2A 500V-4A 690/660V-2A according to UL, CSA A600 A600 DC 13 Rated voltage and current Ue-le according to IEC 24V-6A 48V-4A 110V-2A 24V-6A 48V-4A 110V-2A 220V-0.7A 440V-0.7A 220V-0.7A 440V-0.7A according to UL, CSA P600 P600 6 6 Electrical endurance ops. 10 10 2 Minimum operational power (operational safety) 17V - 5mA 17V - 5mA .38 Short-circuit protection Max. fuse class gl-gG without welding (A) 10 10 Insulation resistance Between contacts (MW) > 10 > 10 Between contacts and earth (MΩ) > 10 > 10 Between input and output (MΩ) > 10 > 10 Guaranteed no overlap between NO and NC contacts Space (mm) 1.3 2.6 Time (ms) 1.5 1.5 Impedance of the contacts (mΩ) 1.28 1.28 Auxiliary contact blocks Instantaneous blocks Timed blocks BCLF..., BCLL..., BRLL BTLF... Rated insulation voltage (Ui) according to IEC 947 (V) 1000 1000 Rated thermal current lth at θ ≤ 55°C (A) 10 10 Making capacity (Ieff) according to IEC AC15/AC11 Ue ≤ 400V, 50/60 Hz (A) 90 90 DC 13/DC11 Ue ≤ 220V DC (A) 90 90 Breaking capacity (Ieff) according to IEC 947 AC15/AC11 Ue ≤ 400V, 50/60 Hz (A) 60 60 DC13/DC11 Ue ≤ 220V, DC (A) 0.95 0.95 AC15 Rated voltage and current Ue-Ie according to IEC 120/110V-6A 230/220V-6A 120/110V-6A 230/220V-6A 400/380V-4A 440/415V-3.5A 400/380V-4A 440/415V-3.5A 500V-2.5A 690/660V-1.5A 500V-2.5A 690/660V-1.5A according to UL, CSA A600 A600 DC13 Rated voltage and curent Ue-Ie according to IEC 24V-4A 48V-2A 110V-0.7A 24V-4A 48V-2A 110V-0.7A 220V-0.3A 440V-0.15A 220V-0.3A 440V-0.15A according to UL, CSA Q600 Q600 6 Electrical endurance 10 ops. 1 1 6 Mechanical endurance 10 ops. 10 5 Minimum operational current (operational safety) 17V - 5mA 17V - 5mA Short-circuit protection Max. fuse class gl-gG without welding (A) 10 10 Insulation resistance Between contacts (MΩ) > 10 > 10 Between contacts and earth (MΩ) > 10 > 10 Between input and output (MΩ) > 10 > 10 Guaranteed no overlap between NO and NC contacts Space (mm) 1.3 1.3 Time (ms) 1.5 5 Impedance of the contacts (mΩ) 1.28 1.28 Timing (ambient temperature between – 25°C and + 55°C) Accuracy – ± 5% 6 Loss of accuracy after 0.5 x 10 ops. – + 20% Loss of accuracy per rise °C (0 - 55°C) – + 0.75% per °C SERIES CL - Technical data Mechanical latch blocks RMLF � � � � � Rated insulation voltage Ui 1000 V Standard voltages Us : 50 to 60 Hz and DC 24...690 V Operating limits 0.75...1.1 xUs Consumption for unlatching (auto cut-out) 24 to 72 V 210 W / VA 110 to 440 V 130 W / VA (1) Electrical unlatching control Minimum pulse 10 ms Maintained auto cut-out by integral contact Manual unlatching control by local push-button Electrical making control Minimum pulse 40 ms auto cut-out by integral contact Manual making control by local push-button Auxiliary contact NC 2 Utilisation AC15/AC11 according to IEC 120V - 6A 500V - 1.5A .39 230V/220V - 4A 690V/660V - 1A 400V/380V - 2.5A according to UL/CSA A600 Utilisation DC13/DC11 according to IEC 24V - 3A 220V - 0.3A 48V - 1.5A 400V - 0.15A 110V - 0.6A according to UL/CSA Q600 Mechanical endurance CL00...CL45 3 million (1200 ops./h) CL05...CL10 0.1 million (300 ops./h) Wiring diagram (1) The contactor coil and the unlatch control must not be energised simultaneously. Terminal capacity for BCLF, BCLL, BTLF and RMLF Solid 2 x 0.5 to 2.5 or 1 x 4 Stranded and finely stranded without end sleeve 2 x 0.5 to 2.5 or 1 x 4 Finely stranded with end sleeve 2 x 0.5 to 2.5 or 1 x 4 AWG wires, solid and stranded 12 - 22 AWG 75°C Wire Tightening torque 1.1 Nm / 10 Lb x in. SERIES CL - Technical data Contact sequence (distance in mm) Open Basic contactor Front mounted auxiliary contact blocks Lateral mounted auxiliary contact blocks BCLF 10 BCLF 01 BCLL 20 BCLL 11 BRLL 20 BRLL 11 Closed Three-pole contactors 3NO 0 3 4.7 0 3 4.7 0 1.6 4.7 0 3 4.7 0 3 4.7 CL00..., CL01..., CL02... 1.6 0 3 5.3 0 3.5 5.3 0 1.8 5.3 0 3.5 5.3 0 3.5 5.3 CL25... 1.8 0 4 5.6 0 3.5 5.6 0 1.8 5.6 0 3.5 5.6 0 3.5 5.6 CL03..., CL04... 1.8 0 4.3 6.7 0 3.5 6.7 0 1.8 6.7 0 3.5 6.7 0 3.5 6.7 2 CL45 .40 1.8 0 3.5 7.8 0 3.5 7.8 0 5.4 7.8 0 3.5 7.8 0 1.8 7.8 CL06... 1.8 0 3.5 7.8 0 3.5 7.8 0 5 7.8 0 3.5 7.8 0 1.8 7.8 CL07..., CL08... 1.8 0 5.6 8 0 3.5 8 0 1.8 8 0 3.5 8 0 3.5 8 CL09... 1.8 0 5.6 8 0 3.5 8 0 1.8 8 0 3.5 8 0 3.5 8 CL10... 1.8 Four-pole contactors 4NO 0 3 4.7 0 3 4.7 0 1.6 4.7 0 3 4.7 0 3 4.7 CL01..., CL02... 1.6 0 4 5.6 0 3.5 5.6 0 1.8 5.6 0 3.5 5.6 0 3.5 5.6 CL03..., CL04... 1.8 0 3.5 7 0 3.5 7 0 5.5 7 0 3.5 7 0 1.8 7 CL05... 1.8 057 0 3.5 7 0 1.8 7 0 3.5 7 0 3.5 7 CL07... 1.8 0 5.6 8 0 3.5 8 0 3.5 8 0 3.5 8 0 3.5 8 CL09... 1.8 Four-pole contactors 2NO + 2NC 0 3.5 4.7 0 3 4.7 0 3 4.7 0 3 4.7 0 1.6 4.7 CL01..., CL02... 1.6 1.6 0 3.5 5.6 0 3.5 5.6 0 4 5.6 0 3.5 5.6 0 1.8 5.6 CL03..., CL04... 1.6 1.8 0 5.5 7 0 3.5 7 0 1.8 7 0 3.5 7 0 3.5 7 CL05... 1.8 2.9 057 0 3.5 7 0 1.8 7 0 3.5 7 0 3.5 7 CL07..., CL08... 3.3 1.8 SERIES CL - Technical data Terminal numbering according to EN 50012 Combinations Final of auxiliary contacts structure of the Possible Auxiliary contact blocks Description NO NC contactor basic contactors to be added Without auxiliary contact blocks CL00 . 310T � CL03 . 310M � CL01 . 310T � CL04 . 310M � 10E 10 CL02 . 310T � CL00 . 301T� CL03 . 301M � CL01 . 301T� CL04 . 301M � 01E 01 CL02 . 301T� Front mounting auxiliary contact blocks with one contact each CL00 . 310T � CL03 . 310M � + BCLF01 CL01 . 310T � CL04 . 310M � 11 11E 2 CL02 . 310T � .41 CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF10 CL01 . 310T � CL04 . 310M � 21E 21 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF01 CL01 . 310T � CL04 . 310M � 12E 12 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF10 CL01 . 310T � CL04 . 310M � + BCLF10 31E 31 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF10 CL01 . 310T � CL04 . 310M � + BCLF10 + BCLF10 41E 41 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF01 CL01 . 310T � CL04 . 310M � + BCLF10 22E 22 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF01 CL01 . 310T � CL04 . 310M � + BCLF10 + BCLF10 32E 32 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF01 CL01 . 310T � CL04 . 310M � + BCLF01 13E 13 CL02 . 310T � CL00 . 310T � CL03 . 310M � + BCLF01 + BCLF01 CL01 . 310T � CL04 . 310M � + BCLF01 + BCLF10 23E 23 CL02 . 310T � Lateral mounting auxiliary contact blocks with two contacts each CL00 . 300T � CL25 . 300M � + BCLL11 CL01 . 300T � CL04 . 300M � 11 11E CL02 . 300T � CL45 . 300M � CL00 . 300T � CL25 . 300M � + BCLL11 + BCLL20 CL01 . 300T � CL04 . 300M � 31E 31 CL02 . 300T � CL45 . 300M � CL00 . 300T � CL25 . 300M � + BCLL11 + BCLL11 CL01 . 300T � CL04 . 300M � 22 22E CL02 . 300T � CL45 . 300M � The maximum number of auxiliary contacts is four for CL00 to CL02 and six for CL03 and CL04. When using the pneumatic BTLF-block, these numbers are reduced to two, resp. four. SERIES CL - Technical data Terminal numbering according to EN 50012 Combinations Final Final of auxiliary contacts structure Possible structure Possible of the basic of the basic Auxiliary contact blocks Description NO NC contactor contactors contactor contactors to be added Without auxiliary contact blocks CL25 . 300T � CL06 . 300M � CL45 . 300T � up to CL10 . 300M � Front mounting auxiliary contact blocks with one contact each CL25 . 300T � CL06 . 300M � + BCLF10 CL45 . 300T � up to 10 10E CL10 . 300M � CL25 . 300T � CL06 . 300M � + BCLF01 CL45 . 300T � up to 01E 01 2 CL10 . 300M � .42 CL25 . 300T � CL06 . 300M � + BCLF10 + BCLF01 CL45 . 300T � up to 11E 11 CL10 . 300M � CL25 . 300T � CL06 . 300M � + BCLF10 + BCLF01 CL45 . 300T � up to + BCLF10 21E 21 CL10 . 300M � CL25 . 300T � CL06 . 300M � + BCLF10 + BCLF01 CL45 . 300T � up to + BCLF01 12E 12 CL10 . 300M � BCLL11 CL06 . 300M � + BCLF10 + BCLF01 up to + BCLF10 + BCLF10 31E 31 CL10 . 300M � CL06 . 300M � + BCLF10 + BCLF01 up to + BCLF10 + BCLF10 41E 41 CL10 . 300M � + BCLF10 CL25 . 300T � CL06 . 300M � + BCLF10 + BCLF01 CL45 . 300T � up to + BCLF01 + BCLF10 22E 22 CL10 . 300M � CL06 . 300M � + BCLF10 + BCLF01 up to + BCLF01 + BCLF10 32E 32 CL10 . 300M � + BCLF10 CL25 . 300T � CL06 . 300M � + BCLF10 + BCLF01 CL45 . 300T � up to + BCLF01 + BCLF01 13E 13 CL10 . 300M � CL06 . 300M � + BCLF10 + BCLF01 up to + BCLF01 + BCLF01 23E 23 CL10 . 300M � + BCLF10 Lateral mounting auxiliary contact blocks with two contacts each CL25 . 300T � CL06 . 300M � + BCLL11 CL45 . 300T � up to 11E 11 CL10 . 300M � CL25 . 300T � CL06 . 300M � + BCLL11 + BCLL20 CL45 . 300T � up to 31E 31 CL10 . 300M � CL25 . 300T � CL06 . 300M � + BCLL11 + BCLL11 CL45 . 300T � up to 22 22E CL10 . 300M � The maximum number of auxiliary contacts is eight ; with BTLF : maximum six. SERIES CL - Technical data Terminal numbering Auxiliary contact blocks Auxiliary contact blocks Three-pole and four-pole contactors Front mounting Lateral mounting BCLF10 BCLL20 CL00A300T � to CL10A300M � BCLF01 CL25D300T � to CL45D300M � BCLL11 CL06E300M � to CL10E300M � BCLF10G BRLL11 BCLF01G CL00 . 310T to CL02 . 310T � BRLL20 2 CL03 . 310M to CL04 . 310M � .43 Pneumatic timer blocks Mechanical latch block BTLF . C CL00 . 301T to CL02 . 301T � RMFL CL03 . 301M to CL04 . 301M � BTLF . D Mechanical interlock Electronic timer blocks BELA BEL CL45A311M � to CL10A311M � BETL02C BELA02 BETL45C BEL02 Interface module BETL02D CL00A400T � toCL08A400M � CL01D400T � to CL04D400M � BETL45D CL05E400M � to CL09E400M � IMRD IMRG Voltage suppressor blocks BSLR2 IMSSD CL25A . 310T � BSLDZ IMRFD IMRFG BCLF01 CL25 . 301T � Voltage suppressor blocks for IMAMS utilisation with interface modules and electronic timers CL01AB00T � to CL08AB00M � CL01DB00T � to CL04DB00M � CL05EB00M � to CL08EB00M � IMRC IMD1Z IMVB SERIES CL - Dimensional drawings Three-pole and four-pole AC contactors Three-pole and four-pole DC contactors AB CL00A3 . . T 85 – CL01A3 . . T 85 – A CL01A4 . . T 85 – CL00D3 . . T 115 CL02A3 . . T 85 – CL01D3 . . T 115 CL02A4 . . T 85 – CL01D4 . . T 115 CL02D3 . . T 115 CL25A300T 87 – CL02D4 . . T – CL25A310T 87 29 CL25A301T 87 29 CL25D300T 117 A CL03A3 . . M – CL03D3 . . M CL03A4 . . M – CL03D4 . . M CL04A3 . . M – 2 CL04D3 . . M CL04A4 . . M – CL04D4 . . M .44 CL45A300M – CL45D300M CL45A311M 29 Three-pole AC contactors Three-pole DC contactors CL06A3 . . M CL06E3 . . M CL07A3 . . M CL07E3 . . M CL08A3 . . M CL08E3 . . M CL09A3 . . M CL09E3 . . M CL10A3 . . M CL10E3 . . M Four-pole AC contactors Four-pole DC contactors CL05A4 . . M CL05E3 . . M CL07A4 . . M CL07E3 . . M CL05AB . . M CL05EB . . M CL07AB . . M CL07EB . . M CL08AB . . M CL08EB . . M CL09A4 . . M CL09E4 . . M SERIES CL - Dimensional drawings Front mounting auxiliary contact blocks Electronic timer block Voltage suppressor block CL00...CL25 CL00...CL25 BCLF CL03...CL45 Lateral mounting auxiliary CL03...CL45 contact blocks CL05...CL10 2 BRLL CL05...CL10 .45 BCLL Pneumatic timer block BSLR BSLDZ BSLV BTL02 BTL45 Interface modules BTLF CL00...CL25 Mechanical latch block RMLF CL03...CL45 Mechanical / mechanical-electrical interlock BELA BEL CL05...CL10 BELA02 BEL02 IMR� IMRF� IMSSD IMAMS

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the BCLL11?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

General Electric CR105X200P Auxiliary Contact Kit